Improving Winery Refrigeration Efficiency Winery a Case Study Report
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Advanced Heat Pump Systems Using Urban Waste Heat “Sewage Heat”
Mitsubishi Heavy Industries Technical Review Vol. 52 No. 4 (December 2015) 80 Advanced Heat Pump Systems Using Urban Waste Heat “Sewage Heat” YOSHIE TOGANO*1 KENJI UEDA*2 YASUSHI HASEGAWA*3 JUN MIYAMOTO*1 TORU YAMAGUCHI*4 SEIJI SHIBUTANI*5 The application of heat pumps for hot water supply and heating systems is expected. Through this, the energy consumption of hot water supply and heating, which account for a substantial proportion of the total energy consumption in a building, will be reduced. The level of reduction can be dramatically increased by use of "sewage heat," which is part of waste heat in an urban area. So far, however, it has been difficult to determine whether sufficient technical or basic data available to widely use sewage heat exists. Therefore, demonstrations on the evaluation method for the potential of sewage heat in an urban area and the actual- equipment scale of verification using untreated sewage were conducted to understand the characteristics of sewage heat, and major technologies for use of sewage heat were developed. The technologies were applied to the system using sewage heat, and the system achieved a 29% reduction in the annual energy consumption and a 69% reduction in the running cost in the hot water system in lodging facilities compared to the conventional system using a boiler. The depreciation timespan of the difference in the initial cost between the conventional system and the heat pump system is about four years, and this system has an economically large advantage. In this report, the results obtained through the development and the demonstrations are systematically organized and the technical information needed for introduction of use of sewage heat is provided. -
World Bank Document
WATER GLOBAL PRACTICE QUALITY UNKNOWN BACKGROUND PAPER Public Disclosure Authorized Determinants of Public Disclosure Authorized Essayas Ayana Declining Water Quality Public Disclosure Authorized Public Disclosure Authorized About the Water Global Practice Launched in 2014, the World Bank Group’s Water Global Practice brings together financing, knowledge, and implementation in one platform. By combining the Bank’s global knowledge with country investments, this model generates more firepower for transformational solutions to help countries grow sustainably. Please visit us at www.worldbank.org/water or follow us on Twitter at @WorldBankWater. About GWSP This publication received the support of the Global Water Security & Sanitation Partnership (GWSP). GWSP is a multidonor trust fund administered by the World Bank’s Water Global Practice and supported by Australia’s Department of Foreign Affairs and Trade, the Bill & Melinda Gates Foundation, the Netherlands’ Ministry of Foreign Affairs, Norway’s Ministry of Foreign Affairs, the Rockefeller Foundation, the Swedish International Development Cooperation Agency, Switzerland’s State Secretariat for Economic Affairs, the Swiss Agency for Development and Cooperation, U.K. Department for International Development, and the U.S. Agency for International Development. Please visit us at www.worldbank.org/gwsp or follow us on Twitter #gwsp. Determinants of Declining Water Quality Essayas Ayana © 2019 International Bank for Reconstruction and Development / The World Bank 1818 H Street NW, Washington, DC 20433 Telephone: 202-473-1000; Internet: www.worldbank.org This work is a product of the staff of The World Bank with external contributions. The findings, interpretations, and conclusions expressed in this work do not necessarily reflect the views of The World Bank, its Board of Executive Directors, or the governments they represent. -
Ion Exchange and Disposal Issues Associated with the Brine Waste Stream
FWRJ Ion Exchange and Disposal Issues Associated With the Brine Waste Stream Julie Karleskint, Daniel Schmidt, Robert Anderson, Jayson Page, and A.J. Berndt he City of Arcadia recently completed from the local water supply authority, it was Julie Karleskint, P.E., is a senior construction of a new 1.5-mil-gal-per- determined that ion exchange would be the associate with Hazen and Sawyer in Tday (mgd) water treatment plant most cost-effective option for construction. A Sarasota. Daniel Schmidt, P.E., is a (WTP) using ion exchange technology to re- reduction in capacity was also provided since senior associate with Hazen and Sawyer place its 3-mgd lime softening WTP. The lime the City’s water supply source, groundwater in Tampa. Robert Anderson, P.E., is a plant had reached the end of its serviceable life from the intermediate aquifer, was limited senior associate with Hazen and Sawyer and the treatment of groundwater for the re- based on current pumping limitations and in Orlando. Jayson Page, P.E., is a moval of radionuclides, hardness, sulfides, or- permitted capacity. senior associate with Hazen and Sawyer ganic carbon, and fluoride was desired in The groundwater is supplied from six order to provide safe drinking water to the wells, approximately 350 ft deep and located in Coral Gables. A.J. Berndt is the utility community. After evaluating several treatment within a 1-mi radius of the plant. A summary director for the City of Arcadia. technologies, including lime treatment, of the water quality from the wellfield is shown nanofiltration, ion exchange, and purchases in Table 1. -
Mechanical Systems Water Efficiency Management Guide
Water Efficiency Management Guide Mechanical Systems EPA 832-F-17-016c November 2017 Mechanical Systems The U.S. Environmental Protection Agency (EPA) WaterSense® program encourages property managers and owners to regularly input their buildings’ water use data in ENERGY STAR® Portfolio Manager®, an online tool for tracking energy and water consumption. Tracking water use is an important first step in managing and reducing property water use. WaterSense has worked with ENERGY STAR to develop the EPA Water Score for multifamily housing. This 0-100 score, based on an entire property’s water use relative to the average national water use of similar properties, will allow owners and managers to assess their properties’ water performance and complements the ENERGY STAR score for multifamily housing energy use. This series of Water Efficiency Management Guides was developed to help multifamily housing property owners and managers improve their water management, reduce property water use, and subsequently improve their EPA Water Score. However, many of the best practices in this guide can be used by facility managers for non-residential properties. More information about the Water Score and additional Water Efficiency Management Guides are available at www.epa.gov/watersense/commercial-buildings. Mechanical Systems Table of Contents Background.................................................................................................................................. 1 Single-Pass Cooling .......................................................................................................................... -
Thermal Desalination Using MEMS and Salinity-Gradient Solar Pond Technology
Thermal Desalination using MEMS and Salinity-Gradient Solar Pond Technology University of Texas at El Paso El Paso, Texas Cooperative Agreement No. 98-FC-81-0047 Desalination Research and Development Program Report No. 80 August 2002 U.S. Department of the Interior Bureau of Reclamation Technical Service Center Water Treatment Engineering and Research Group Form Approved REPORT DOCUMENTATION PAGE OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suit 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Report (0704-0188), Washington DC 20503. 1. AGENCY USE ONLY (Leave Blank) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED August 2002 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS Thermal Desalination using MEMS and Salinity-Gradient Solar Pond Technology Agreement No. 98-FC-81-0047 6. AUTHOR(S) Huanmin Lu, John C. Walton, and Herbert Hein 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER University of Texas at El Paso El Paso, Texas 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING/MONITORING Bureau of Reclamation AGENCY REPORT NUMBER Desalination Research and Denver Federal Center Development Program Report No. -
Leachate Generated by an Oil - and - Gas
ISSN: 0078-1576 ~ ~ o ~ ~ o ::r: f a:: o z z Leachate Generated by an Oil - and - Gas UJ ~ Brine Pond Site in North Dakota (/) 0.. zl" 0.0o· by LLJz ~~ Edwa rd C. Mu rphy a:: "1: Alan E. Kehew !Xl Cll (/) Gerald H. Groenewold (/)111 William A. Beal ~:J <':>0 I CIl QC: z~ «CIl I 0 -Jill O::e z> «~ >-; !Xl(/) Q UJ~ ~" «~ a::w2 Zt:) LLJ <.:>~ UJ~ ~/11 «0 ::r: U L.... f«L. LLJO -Jz III L. ell ..c MISCELLANEOUS SERIES 71 +'"o NORTH DAKOTAGEOLOGICALSURVEY 1J Sidney B. Anderson, c Acting State Geologist /11 1988 Reprinted from the January-February 1988, Volume 26, Number 1 issue of Ground Water Leachate Generated by an Oil-and-Gas Brine Pond Site in North Dakota by Edward C. Murphya, Alan E. Kehewb, Gerald H. Groenewoldc , and William A. Beal d ABSTRACT INTRODUCTION Two unlined ponds were used for holding and Brines typically are produced along with evaporation of brines produced with oil and gas at a well crude oil at oil-well sites. These brines are recog site in north-centra! North Dakota. The brine-evaporation nized as the major source of potential environ ponds were in use from 1959 up to the late 1970s when mental contamination associated with oil produc they were backfilled and leveled. Continued salt-water migration at this site since closure has decreased crop yields tion (Knox and Canter, 1980). The issue of how to in surrounding fields and has killed trees in a shelterbel t properly dispose of oil-field brines has been con within an area of approximately 10 acres. -
Appendix A: Distillation and Reverse Osmosis Brine NOD, Phase I
This document is part of Appendix A and includes Distillation and Reverse Osmosis Brine: Nature of Discharge for the “Phase I Final Rule and Technical Development Document of Uniform National Discharge Standards (UNDS),” published in April 1999. The reference number is EPA-842-R-99-001. Phase I Final Rule and Technical Development Document of Uniform National Discharge Standards (UNDS) Distillation and Reverse Osmosis Brine: Nature of Discharge April 1999 NATURE OF DISCHARGE REPORT Distillation and Reverse Osmosis Brine 1.0 INTRODUCTION The National Defense Authorization Act of 1996 amended Section 312 of the Federal Water Pollution Control Act (also known as the Clean Water Act (CWA)) to require that the Secretary of Defense and the Administrator of the Environmental Protection Agency (EPA) develop uniform national discharge standards (UNDS) for vessels of the Armed Forces for “...discharges, other than sewage, incidental to normal operation of a vessel of the Armed Forces, ...” [Section 312(n)(1)]. UNDS is being developed in three phases. The first phase (which this report supports), will determine which discharges will be required to be controlled by marine pollution control devices (MPCDs)—either equipment or management practices. The second phase will develop MPCD performance standards. The final phase will determine the design, construction, installation, and use of MPCDs. A nature of discharge (NOD) report has been prepared for each of the discharges that has been identified as a candidate for regulation under UNDS. The NOD reports were developed based on information obtained from the technical community within the Navy and other branches of the Armed Forces with vessels potentially subject to UNDS, from information available in existing technical reports and documentation, and, when required, from data obtained from discharge samples that were collected under the UNDS program. -
Analysis and Optimization of Open Circulating Cooling Water System
water Article Analysis and Optimization of Open Circulating Cooling Water System Ziqiang Lv 1,2,3, Jiuju Cai 2, Wenqiang Sun 1,2,* and Lianyong Wang 1,2 1 Department of Thermal Engineering, School of Metallurgy, Northeastern University, Shenyang 110819, Liaoning, China; [email protected] (Z.L.); [email protected] (L.W.) 2 State Key Laboratory of Eco-Industry, Northeastern University, Shenyang 110819, Liaoning, China; [email protected] 3 School of Civil Engineering, University of Science and Technology Liaoning, Anshan 114051, Liaoning, China * Correspondence: [email protected] Received: 22 September 2018; Accepted: 26 October 2018; Published: 7 November 2018 Abstract: Open circulating cooling water system is widely used in process industry. For a system with a fixed structure, the water consumption and blowdown usually change with the varying parameters such as quality and temperature. With the purpose of water saving, it is very important to optimize the operation strategy of water systems. Considering the factors including evaporation, leakage, blowdown and heat transfer, the mass and energy conservation equations of water system are established. On this basis, the quality and temperature models of makeup and blowdown water are, respectively, developed. The water consumption and discharge profiles and the optimal operating strategy of the open recirculating cooling water system under different conditions are obtained. The concept of cycles of temperature is proposed to evaluate the temperature relationship of various parts of the open circulating cooling water system. A mathematical relationship is established to analyze the influence of the water temperature on the makeup water rate of the system under the condition of insufficient cooling capacity of the cooling tower. -
Reclaiming Resources: Reducing Water Consumption Through Reuse
Reclaiming Resources: Reducing Water Consumption through Reuse Although water reuse can be energy-intensive, its use is increasing across numerous industries By: Al Goodman Al Goodman is a principal with 42 years of experience serving clients in water reuse projects at the Louisville, Ky., office of CDM Smith (Boston). Communities and industries around the world are turning to water reuse. The drivers are varied: the need to augment strained water supplies, reduce nutrients in treated effluent, maintain ecological balance, use the most energy-efficient water sources, and reduce cost of purchased and treated water. The major driver is water scarcity in arid and semi-arid regions, though some regions of the world that are not considered to be water-scarce are implementing water reuse. Ecological drivers are becoming more important in evaluating reuse as part of a response to rigorous and costly requirements to reduce or remove nutrients (mainly nitrogen and phosphorus) from discharges to surface waters. Though water reuse can be energy-intensive, depending on the level of treatment required, only a full life-cycle analysis can reveal whether overall resource costs are greater than or less than alternative water supplies. Municipalities are implementing various types of urban water reuse and turning to industry and agriculture as potential customers of reclaimed water. Categories of water reuse applications are presented in the table. This article focuses on considerations relevant for municipal and industrial reuse. For more information on the full range of categories of reuse, refer to the U.S. Environmental Protection Agency’s Guidelines for Water Reuse (2012; http://nepis.epa.gov/Adobe/ PDF/P100FS7K.pdf). -
Treatment of Concentrate
Desalination and Water Purification Research and Development Program Report No. 155 Treatment of Concentrate U.S. Department of the Interior Bureau of Reclamation May 2009 REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. T T T T T 1.T REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) March 9, 2008 Final 2002–2008 4.T TITLE AND SUBTITLE 5a. CONTRACT NUMBER Treatment of Concentrate Agreement 04-FC-81-1050 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Mike Mickley, P.E., Ph.D. 5e. TASK NUMBER Task F 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT Mickley & Associates NUMBER 752 Gapter Road Boulder CO 80303 9. -
Ph Measurements in Salt Solutions Using Differential Technique
pH Measurements in Salt Solutions Using Differential Technique Industry: Brine Soultions Product: PH450, PH202, SC24V, SM23-AN4, SM23-AN6 3. High Currents Application and Associated pH Chlorinated Brine is measured often close to the electrolysis Problems Cells, where very high currents are present. These currents will easily cause Ground Loop Currents in the pH sensor circuit, which again shortens the lifetime. pH measurement in brine solutions (for example NaCl solutions as found in electrolysis processes or cheese manufacturing) are difficult and inaccuracy and short sensor Alternative Solutions life are the key problems in these applications. These troubles are caused by: Evidently the problems are not related to the pH measuring cell, but almost exclusively to the reference cell. 1. Potential difference Therefore the solution of the problem must be sought in The brine ions tend to create large diffusion potentials in the alternative ways of generating a reference voltage, that is reference junction. The equivalent conductance of a stable over time and is independent on the pH value. Potassium ion (K+) and a Chloride ion (Cl-) are almost the same: ( 75 Scm2equiv-1). That is why KCl is used normally We have found that an excellent solution is to use a for electrolyte solution in reference cells. The equivalent Yokogawa SM23 - AN4/AN6 type of pNa electrode and conductance of Sodium ion is much less with 50 and of the connect this to the high impedance reference input of the pH Hydronium ion is much higher with 200! Diffusion of these converter or transmitter (terminal 13 and shield to terminal solutions ( Brine and Muratic acid) into the junction causes 17) or the SC24 VP 4-in-1 pNa electrode. -
Barwon Water Biosolids Management Project Operations
BARWON WATER BIOSOLIDS MANAGEMENT PROJECT OPERATIONS Paper Presented by: Tony Davies Author: Tony Davies, Operations Manager Barwon Water Biosolids Management Project, Water Infrastructure Group 77th Annual WIOA Victorian Water Industry Operations Conference and Exhibition Bendigo Exhibition Centre 2 to 4 September, 2014 77th WIOA Victorian Water Industry Operations Conference & Exhibition Page No. 70 Bendigo Exhibition Centre, 2 to 4 September, 2014 BARWON WATER BIOSOLIDS MANAGEMENT PROJECT OPERATIONS Tony Davies, Ops Manager Barwon Water Biosolids Mgmt Project, Water Infrastructure Group ABSTRACT The Barwon Water Biosolids Management Facility is the first of its kind in Australia, and the largest in the Southern Hemisphere and has now been operating for 18 months. The innovative, small footprint, fully enclosed thermal drying plant produces T1 Treatment Grade pelletised biosolids that are suitable for reuse as farm fertilizer and soil conditioner that can be safely handled and easily transported immediately after processing. T1 classification for biosolids is the microbiological criteria and measure used to inhibit bacterial regrowth and odour. T1 is the highest classification. The plant operates 24/7 and has capacity to treat 60,000 tonne of biosolids per annum. The plant receives biosolids at >13% from seven wastewater treatment plants in the Geelong region and produces pellets at >90% dry solids. The Facility is one of the projects in the water sector to be delivered as a Public Private Partnership. Water Infrastructure Group designed