A Comparison of Two Techniques for R-Value Calculation, Using Winter In-Situ Data

Total Page:16

File Type:pdf, Size:1020Kb

A Comparison of Two Techniques for R-Value Calculation, Using Winter In-Situ Data A COMPARISON OF TWO TECHNIQUES FOR R-VALUE CALCULATION, USING WINTER IN-SITU DATA Stephen N. Flanders Andre O. Desjarlais Timothy J. Kunz ABSTRACT Tllis stlldy employed will tel' ill-sitll temperatllre alld lIeat fllIX least sqllares. Tllese leclllliqlles were applied to tile data ob­ data from a blli/dillg ill Nortll Dakota alld two bllildillgs ill tailled alld tile res liltS call/pared. Tile colllparisoll reported ill IIpstate New York. Tile alltllors obtailled tile temperatllre alld tllis stlldy was of tile estill/ate of tile R-vaille obtailled, tile lIeat fllIX data accordillg to ASTM Stalldard Practice C 1046- speed at wllicll a stable vallie was obtailled, alld all assessmellt 91. A proposed revisioll of ASTM Stalldard Practice C 1155 of tile COllditiolls tllat provided tile 1II0St reliable res lilts frolll illellldes two enlcllialiollal teclllliqlles, sllmllwtioll, alld Slllll of eaell calclilatioll. INTRODUCTION understand the geometry of heat flow in the building cOlllponent to be nleasured, sometimes lIsing infrared Determination of In-Situ Thermal Resistance thermography. The user then strives to place the instru­ with one-dimen­ Determination of thermal resistance or R-value of mentation in areas predonlinantly sional heat flow perpendicular to the surface of the building envelope components is useful to ensure that component. The teclmiques are further limited to light­ construction standards have been filet or as a tool to and medium-weight construction. Courville et aJ. (1990) assess needed improvements in insulating levels. Such a fmOld that agreement between the hl'o teclmiques determination is more difficult to accomplish in settings improved when the measured heat flux was greater of actual use than in the laboratory because of the delays than ±1.5 W 1m2 (0.5 in thermal signals caused by thermal storage and insula­ Bh!/h.f~). tion effects. 11lis paper compares two teclmiques for cal­ Summation Technique The sUllunation teclulique culating R-value from in-situ data. uses accumulated temperature and heat flux data to esti­ In-Situ Data Two American Society for Testing and mate thermal resistance as follows: Materials (ASTM) standards are available for measuring L [T;n (I) - T",,, (t) 1 in-sih! temperature and heat flux data-C 1046-91 t:;: 0 (ASTM 1991) and then for determining thermal resis­ II (t) = '----'--:=----- (1) L q(t) tance from them, C 1155-90 (ASTM 1990c). In Europe, a t:o; 0 standard is under development to accomplish the same purpose (draft ISO Standard 9869). A variety of calcula­ where f is titne and T and q are the temperature and heat tional teclmiques have been proposed and tried, includ­ flux at a surface. ing modified summation teclmiques (Anderson 1986), Sum-of· Least-Squares Technique The sum-of-Ieast­ multiple linear regression (Anderlind 1992), sum-of­ squares technique adapts to multiple sensors placed at least-squares techniques (Beck et aJ. 1991; Bomberg et aJ. several boundaries between hOlnogeneous layers within 1994), and Fourier analysis (draft ISO Standard 9869). an insulated component. It assumes that one-dinlen­ 11,is paper focuses on comparing the hl'o procedures sional, transient conduction is the heat transfer mecha­ proposed for C 1155-90-the stunmation technique and nism. TIle governing equation, allowing for variable­ the sum-of-Ieast-squares technique. temperature thermal properties, is as follows: Assumptions Both techniques place constraints on a ( aT) aT aT (2) how the data were obtained. They require that the user dx A'dX = (p' Cp ) at with q = -A,ax Stephen N. Flanders Is with the U.S. Army Cold Regions Research and Engineering Laboratory, Hanover, N.H. Andre O. DeSjarlais Is with Ook Ridge National Laboratory, Oak Ridge, Tenn. Timothy J. Kunz Is with Holometrix, Inc .. Bedford, Mass. Thermal Envelopes VI/Heat Transfer in Walls I-PrinCiples 151 where A is thermal conductivity and p and Cp are the Significant ~T. Therefore, long-term data sets were used material density and specific heat, respectively. wherever possible. TIlis teclulique solves Equation 2 numerically, using Speed of Determination Because of the delays in the Crank-Nicholson method, to obtain a finite-differ­ obtaining an output thermal signal of temperature 01' ence approximation. The measured temperature and/or heat flux on one side of the construction when the oppo­ heat flux histories on each side of the building compo­ site side has changes in temperature, it can take days to nent are the boundary conditions. One typically esti­ obtain a valid determination of R-value. If one teclmique mates apparent thermal conductivity as a function of is faster than the other in determining the final value temperature and a constant value of the product p and reliably, it would be preferred. Consequently, the authors compared the time that elapsed before each CII for each layer described in the system. teclulique began to stay within 10% of its final estimate To obtain the best estimates for as many parameters of R-value. as required, one computes temperatures and heat fluxes Sensitivity to ~T It was mentioned previously with trial initial values of the parameters. Next, one (Courville et al. 1990) that the sum-of-least-squares tech­ compares thenl to measurements at the interior nodes, nique succeeds at lo\\' !lTs, whereas the sumlnation tech­ where independent Ineasurements are available. Then nique becomes unstable when the denominator of one COInputes a weighted sllln~of-squares function, r, Equation 1 is near zero as a cUlnulative result of rever­ from the differences between calculated and measured sals of ~T. TIle sum-of-least-squares teclmique works heat fluxes and temperatures, as follows: well during changing ~T, even when ~Ts are small, because iJT liJt is the key variable in Equation 2. Does this or any other aspect of ~T cause a more reliable or rapid solution for one technique or the other? Indica­ tions were sought that may have made one teclUlique where each W is a weighting fact01~ Tllli and qlli are the calculated temperature and heat flux at a node 111 or 11, advantageous over the other. and a time i and F ; are the measured temperature and II Comparison of Measurement Sites heat flux at a node 111 or 11 and a titne i. Finally, one uses the Gauss linearization method Table 1 summarizes the building locations and types. (Beck and Arnold 1977) to minimize r as the analysis TIle climatic conditions, Ineasurement duration, and iterates with better and better estimates of the desired building types are significant to the outcome of the mea­ properties until the desired convergence is obtained. surements. With only t\vo surfaces instrumented, the assembly was TABLE 1 Summary of R-Value Measurement Locations approximated as a unifol'ln slab and values were assluned for thernlal conductivit}~ thickness, density, Component Duration of and specific heat as a starting point for the estimate. It Location Type Measured Measurement was further assumed that thermal conductivity varies with temperature. Riverdale, Metallnsuloted Walls 467 hours N.D. Panel Comparison of Techniques Fort Drum. Metal Insulated Wall 331 hours N.Y. Panel Previous experience with the sununation and the Masonry Wall. Attic 240 hours sum-of-least-squares teclUliques (Courville et al. 1990) suggests that the latter teclUlique is advantageous at Cold Climates TIle experience in previous ,vork in times of low temperature difference (~n between a temperate climate (Courville et al. 1990) suggested indoors and outdoors. The purpose of this study was to choosing a colder clinlate to expand the wlderstanding compare the two tecluliques at conditions with a higher of the effects of tlT on R-value measurements. Riverdale, ~T. Three points of comparison are of interest: (1) N.D., and Fort Drum, N.Y., have temperahlres that reach whether they obtain the same correct answer, (2) how -20"C (-4"F) and below. quickly they reach that answel~ and (3) the sensitivity of Building Types 111e building in Riverdale was a each teclmique to temperature conditions such as ~T heated maintenance building serving the Corps of Engi­ and variations in !IT. neers' Garrison Dam, with metal panels that sand­ R-Value Agreement TIle authors compared how wiched 51 mm (2 in.) of fiberglass insulation between closely the hvo techniques came to producing the same steel skins. TIle buildings at Fort Drum serve military R-value. It was impossible to test independently for purposes. The metal-paneled building was a motor \\'hether the value was correct; however, experience sug­ vehicle maintenance building, where the lllechanical gests that any biases due to calculation and not instru­ foom was instnnnented, \\'hich also had 51 nun (2 in.) of mentation becOIne small with titne in the presence of a fiberglass insulation sandwiched between steel skins on 152 Thermal Envelopes VI/Heat Transfer in Wolfs I-Principles the walls. The masonry building serves as a battalion Roof headquarters. Its walls-which consisted of 102-nun [J I!J (4-in.) brick, 25-mm (I-in.) air space, 51 rnrn (2 in.) of foil­ Metal Panel faced polyisocyanurate insulation, and 203-mm (8-in.) EI Group 3 I!JEJ Group 2 concrete masonry units-were instrumented. Likewise, EI I!J Metal the attic, with its 254 mm (10 in.) of fiberglass insulation, Panel was instrumented. Masonryl El Masonryl Metal EJ Group 1 Metal FIELD PROCEDURES Panel Panel Ii1I Heat flux and temperature data were obtained using oor the procedures in ASTM Standard Practice C 1046-91. In North Side South Side each case, a thermographic survey was performed using the techniques discussed in ASTM Standard Practice C Figure 1 Location of sensor sites at the Riverdale, NO, 1060-90 (ASTM 1990a), which revealed no unexpected building. (Nolto scale.) thennal anomalies. Instrumentation TI,e heat flux transducers (HFrs) Sensor Group 3 - Sensors 7, 8, and 9 were placed on used were 305 mm (12 in.) square, 0.81 nun (0.032 in.) the same north-facing wall as sensor group 1, above the thick, and had an active metering area of 152 mm (6 in.) masonry block level on insulated metal panels.
Recommended publications
  • Causal Heat Conduction Contravening the Fading Memory Paradigm
    entropy Article Causal Heat Conduction Contravening the Fading Memory Paradigm Luis Herrera Instituto Universitario de Física Fundamental y Matematicas, Universidad de Salamanca, 37007 Salamanca, Spain; [email protected] Received: 1 September 2019; Accepted: 26 September 2019; Published: 28 September 2019 Abstract: We propose a causal heat conduction model based on a heat kernel violating the fading memory paradigm. The resulting transport equation produces an equation for the temperature. The model is applied to the discussion of two important issues such as the thermohaline convection and the nuclear burning (in)stability. In both cases, the behaviour of the system appears to be strongly dependent on the transport equation assumed, bringing out the effects of our specific kernel on the final description of these problems. A possible relativistic version of the obtained transport equation is presented. Keywords: causal dissipative theories; fading memory paradigm; relativistic dissipative theories 1. Introduction In the study of dissipative processes, the order of magnitude of relevant time scales of the system (in particular the thermal relaxation time) play a major role, due to the fact that the interplay between this latter time scale and the time scale of observation, critically affects the obtained pattern of evolution. This applies not only for dissipative processes out of the steady–state regime but also when the observation time is of the order of (or shorter than) the characteristic time of the system under consideration. Besides, as has been stressed before [1], for time scales larger than the relaxation time, transient phenomena affect the future of the system, even for time scales much larger than the relaxation time.
    [Show full text]
  • FHF02SC Heat Flux Sensor User Manual
    Hukseflux Thermal Sensors USER MANUAL FHF02SC Self-calibrating foil heat flux sensor with thermal spreaders and heater Copyright by Hukseflux | manual v1803 | www.hukseflux.com | [email protected] Warning statements Putting more than 24 Volt across the heater wiring can lead to permanent damage to the sensor. Do not use “open circuit detection” when measuring the sensor output. FHF02SC manual v1803 2/41 Contents Warning statements 2 Contents 3 List of symbols 4 Introduction 5 1 Ordering and checking at delivery 8 1.1 Ordering FHF02SC 8 1.2 Included items 8 1.3 Quick instrument check 9 2 Instrument principle and theory 10 2.1 Theory of operation 10 2.2 The self-test 12 2.3 Calibration 12 2.4 Application example: in situ stability check 14 2.5 Application example: non-invasive core temperature measurement 16 3 Specifications of FHF02SC 17 3.1 Specifications of FHF02SC 17 3.2 Dimensions of FHF02SC 20 4 Standards and recommended practices for use 21 4.1 Heat flux measurement in industry 21 5 Installation of FHF02SC 23 5.1 Site selection and installation 23 5.2 Electrical connection 25 5.3 Requirements for data acquisition / amplification 30 6 Maintenance and trouble shooting 31 6.1 Recommended maintenance and quality assurance 31 6.2 Trouble shooting 32 6.3 Calibration and checks in the field 33 7 Appendices 35 7.1 Appendix on wire extension 35 7.2 Appendix on standards for calibration 36 7.3 Appendix on calibration hierarchy 36 7.4 Appendix on correction for temperature dependence 37 7.5 Appendix on measurement range for different temperatures
    [Show full text]
  • Convective Heat Flux Explained.Indd
    Convective heat flux explained Theory Thermal convection is one of the three mechanisms of heat transfer, besides conduction and thermal radia- tion. The heat is transferred by a moving fluid (e.g. wind or water), and is usually the dominant form of heat transfer in liquids and gases. Convection can be divided into natural convection and forced convection. Generally, when a hot body is placed in a cold envi- rameters like velocity of the fluid, material proper- ronment, the heat will flow from the hot body to the ties etc. For example, if one blows air over the tea cup, cold surrounding until an equilibrium is reached. the speed of the fluid is increased and thus the heat Close to the surface of the hot body, the surrounding transfer coefficient becomes larger. This means, that air will expand due to the higher temperature. There- the water cools down faster. fore, the hot air is lighter than the cold air and moves upwards. These differences in density create a flow, Application which transports the heat away from the hot surface To demonstrate the phenomenon of convection, the to the cold environment. This process is called natu- heat flux of a tea cup with hot water was measured ral convection. with the gSKIN® heat flux sensor. In one case, air was When the movement of the fluid is enhanced, we talk blown towards the cup by a fan. The profile of the about forced convection: An example is the cooling of a hot body with a fan: The fluid velocity is increased and thus the device is cooled faster, because the heat transfer is higher.
    [Show full text]
  • Heat Flux Measurement Practical Applications for Electronics
    Heat Flux Measurement Practical Applications for Electronics Heat flux sensors are practical measurement tools which are component may be known, as well as the resistance of the useful for determining the amount of thermal energy passed board and solder connections; the resistance at the interface through a specific area per unit of time. Heat flux can be of the component and board to the ambient are not easily thought of as the density of transferred power, similar to known and are dependent on the flow characteristics. While current through a wire or water through a pipe. Measuring analytical or CFD methods can at best predict the heat heat flux can be useful, for example, in determining the transfer coefficient at a particular area, often for complex amount of heat passed through a wall or through a human systems with uneven or sparsely populated components body, or the amount of transferred solar or laser radiant these methods are not accurate and may not be useful. For energy to a given area. In a past article [1] we learned how those components which generate power, but may not need heat flux sensors operate and how they can be calibrated. But the use of a separate heatsink, the heat flux gage can be how can heat flux sensors be used for electronics design? experimentally used to determine the heat transfer coefficient This article highlights several practical uses of the heat flux on the component surface or the compact thermal response sensor in the design of electronics systems. See Figure 1 for on the board (e.g.
    [Show full text]
  • Thermal Metrics for High Performance Enclosure Walls: the Limitations of R-Value
    building science.com © 2009 Building Science Press All rights of reproduction in any form reserved. Thermal Metrics for High Performance Enclosure Walls: The Limitations of R-Value Research Report - 0901 2007 John Straube Abstract: This document summarizes the theory behind thermal insulation and building system heat flow control metrics and presents a literature review of selected research into this area. RR-0901: Thermal Metrics for High Performance Enclosure Walls: The Limitations of R-Value Review of the R-value as a Metric for High Thermal Performance Building Enclosures. 1 Introduction The R-value was developed over 50 years ago to provide users and specifiers of insulation with an easy-to-compare, repeatable measure of insulation performance. Everett Schuman, an early director of Penn State’s housing research institute, is often credited with first proposing (in 1945) and popularizing standardized measures of resistance to heat transfer. R-values were later widely applied to industrial and residential insulating materials and helped consumers make more energy-efficient choices. The strength of the R-value is that it is simple to measure, easy to communicate, and widely accepted. Over recent decades a much broader range of insulation types, and application methods of insulation have been developed and deployed than were available when the R-value was conceived. As the building industry strives to reduce energy consumption for environmental and economic reasons, building enclosures with high thermal performance, reliably and affordably installed in the field are demanded. The R-value of the insulation products in many of the new building enclosure systems is increasingly unable to measure their actual thermal performance because system effects, sensitivity to construction defects, and airflow can play such a significant role in overall performance.
    [Show full text]
  • Quantification of Fourth Generation Kapton Heat Flux Gauge Calibration Performance
    Quantification of Fourth Generation Kapton Heat Flux Gauge Calibration Performance A THESIS Presented in Partial Fulfillment of the Requirements for the Degree Master of Science in the Graduate School of The Ohio State University By Matthew Paul Hodak B.S. Graduate Program in Mechanical Engineering The Ohio State University 2010 Master’s Examination Committee: Dr. Charles W. Haldeman, Advisor Dr. Michael G. Dunn Copyright by Matthew Paul Hodak 2010 ABSTRACT Double sided Kapton heat flux gauges which are used routinely by the Ohio State University Gas Turbine Laboratory are driven by two main calibrations, the sensors temperature as a function of resistance and the material properties of Kapton. The material properties separate into those that govern the steady-state response of the gauge and those that influence the transient response. The steady-state response, as it forms the key to data processing, will be the topic of this investigation and is based on the thermal conductivity divided by the thickness (k/d). Calibration accuracies for the heat flux gauge sensors reached levels on the order of +-.05 °C and were well within the target accuracy of +- 0.1 °C over a 100 °C calibration range. Time degradation of the gauges did occur and for these cases and a single point calibration method is introduced that maintains the accuracy to ±0.4 °C instead of the ± 3 °C that would have resulted from the resistance shift due to erosion. This method will allow for longer use of the gauges in the turbines. Various calibration methods for k/d were investigated and performed.
    [Show full text]
  • Heat Flux Sensors.Cdr
    Heat Flux Sensor A heat flux sensor is a transducer that generates an electrical signal proporonal to the total heat rate applied to the surface of the sensor. The measured heat rate is divided by the surface area of the sensor to determine the heat flux. careful design, rugged quality construcon and versale mounng configuraons. Each transducer will provide a self- generated 10-millivolts (nominal) output at the design heat flux level. Heat Flux gauge absorb heat in a thin metallic circular foil and transfer the heat radially (parallel to the absorbing surface) to the heat sink welded around the periphery of the foil. The emf output is generated by a single differenal thermocouple between the foil center temperature and foil edge temperature. Technical Parameters Parameters Cooled Uncooled Heat Flux (maximum) 10, 30 W/cm² 10, 30 W/cm² Sensor Output Linear output, 10mv nominal at full range Linear output, 10mv nominal at full range Over Range 25% of Rated Heat Flux 25% of Rated Heat Flux Accuracy ±5% or Better ±5% or Better Repeatability 1% 1% Measurement Duration 60s for 10 W/cm² 60s for 10 W/cm² Sensor Differential Thermocouple Differential Thermocouple Dimension Diameter 25mm, Length 25mm Diameter 25mm, Length 25mm Mounting Flange Flange Standard Features Ÿ Linear Output Ÿ Output Proporonal to Heat Transfer Rate Ÿ Accurate, Rugged, Reliable Ÿ Convenient Mounng Ÿ Measure Total Heat Flux Ÿ Measure Radiant Heat Flux www.tempsens.com Heat Flux Sensor Standard configuraon of cooled/uncooled models Ÿ The sensor is provided with or without provision for water cooling of transducer body.
    [Show full text]
  • Examination of Heat Flux Through a Surface Using Digital Image Processing of Infrared Images
    University of Tennessee at Chattanooga UTC Scholar Student Research, Creative Works, and Honors Theses Publications 5-2015 Examination of heat flux through a surface using digital image processing of infrared images Nicholas D. true University of Tennessee at Chattanooga, [email protected] Follow this and additional works at: https://scholar.utc.edu/honors-theses Part of the Mechanical Engineering Commons Recommended Citation true, Nicholas D., "Examination of heat flux through a surface using digital image processing of infrared images" (2015). Honors Theses. This Theses is brought to you for free and open access by the Student Research, Creative Works, and Publications at UTC Scholar. It has been accepted for inclusion in Honors Theses by an authorized administrator of UTC Scholar. For more information, please contact [email protected]. Examination of Heat Flux Through a Surface Using Digital Image Processing of Infrared Images Nicholas True Departmental Thesis The University of Tennessee at Chattanooga Mechanical Engineering Project Director: Dr. Charles Margraves, Ph. D. Examination Date: March 4, 2015 Committee Members: Dr. Gary McDonald, Ph. D. Dr. Trevor Elliott, Ph. D. Dr. Linda Frost, Ph. D. Signatures: __________________________________________________________________ Project Director __________________________________________________________________________________ Department Examiner __________________________________________________________________________________ Department Examiner ___________________________________________________________________________________
    [Show full text]
  • Fundamentals of Heat Transfer in Thermal Interface Gap Filler Materials
    Fundamentals of Heat Transfer in Thermal Interface Gap Filler Materials Introduction This paper focuses on the primary function of a thermal gap filler – its ability to transfer heat from one surface to another. The selection process for a gap filler can sometimes be confusing because most thermal considerations are left to the end of the design cycle when the selection process must be performed under a tight schedule. This paper will describe steps to making the selection process simpler. Figure 2. In a basic thermal solution in electronic assembly, the most common thermal resistances are the case of the component, the thermal gap filler (TIM), and the heat sink. Terms and Units Prior to beginning a discussion on heat transfer in as thermal resistance, whether in °C2/Watt or °C/Watt. thermal interface gap filler materials, a number of terms These are just temperature gradients per power; the and units require definition. The most common term is absolute temperature is more a function of the ambient. thermal resistance. This is the reciprocal of conductivity Watts/mK do not include contact resistance when that includes contact resistance. It is not just thermal discussing TIMs. Just like ASTM 5470, for example, the resistance of the bulk material, but also contact resistance delta of the thermal resistance and the change in thickness between the hot and cold sides. are used to calculate conductivity. Thermal resistance or Thermal gap fillers are a particular type of thermal thermal impedance is shown in values of °C2/Watt or as interface material (TIM) used to fill in gaps between cold °C/Watt if the geometry is called out explicitly.
    [Show full text]
  • The Effects of Temperature on Insulation Performance: Considerations for Optimizing Wall and Roof Designs
    The Effects of Temperature on Insulation Performance: Considerations for Optimizing Wall and Roof Designs Chris Schumacher and John Straube, PEng Building Science Consulting, Inc. 167 Lexington Court, Unit 6, Waterloo, Ontario N2J 4R9 Phone: 519-342-4731 • Fax: 519-885-9449 • E-mail: [email protected] Lorne Ricketts, EIT, and Graham Finch, PEng RDH Building Engineering, Ltd. 224 W. 8th Avenue, Vancouver, British Columbia V5Y 1N5 Phone: 604-873-1181 • Fax: 604-873-0933 • E-mail: [email protected] 3 1 ST R C I I NTE R NAT I ONAL C ONVENT I ON AND T R ADE S HOW • M A rc H 10-15, 2016 S C HU M A C HE R ET AL . • 1 6 5 Abstract Recent research into the real-world performance of insulation materials in roofs and walls has shown that the industry’s reliance on R-value at a standard temperature does not always tell the whole story. This paper will present measurements from several field- monitoring studies across North America that demonstrate how insulated roofs and walls exhibit thermal performance that is different than assumed by designers. Specifically, results show that insulation properties vary with temperature (i.e., performance changes at high or low temperatures). This is important because of peak energy demand, annual heat- ing and cooling costs, occupant comfort, and durability considerations. Speakers Chris Schumacher — Building Science Consulting, Inc. CHRISTOPHER SCHUMACHER is a principal with Building Science Consulting, Inc. (BSCI), a consulting firm specializing in design facilitation, building enclosure commis- sioning, forensic investigation, and training and communications. Its research division, Building Science Laboratories (BSL), provides a range of research and development services.
    [Show full text]
  • Hukseflux Thermal Sensors
    Hukseflux Thermal Sensors How to install a heat flux sensor Tips and tricks to get the most out of your heat flux measurement Measuring heat flux is a powerful tool to gain insights in processes. You may measure for example how much heat flows through a wall, or to a specimen that must be cooled. Assuming the right sensor is used, installing this sensor correctly, so that it performs a stable measurement and measures the right heat flux (radiative and convective), is a critical step to get the right data. This paper dives into the do’s and don’ts when installing a heat flux sensor. Introduction General considerations for heat flux Heat flux sensors have a wide variety of measurement applications, from thermal performance analysis • Use the right sensor for the application. of thermal insulation, to monitoring of fouling of There are many different models each with pipelines and the health monitoring of pigs. its own temperature- and heat flux range. Measuring the heat flux can lead to useful Hukseflux can assist you to make the right insights in processes and system performance. choice for your application. Assuming the right sensor is used, mounting this • Perform a representative measurement. This sensor correctly, so that it performs a stable starts with choosing the right location, measurement and measures the right heat flux representative for the system to be (radiative and convective), is a critical step to get monitored. Use multiple sensors. The the right data. representativeness may be reviewed using infrared cameras. This paper focuses on sensor installation. What • See also our video on YouTube: how to are the do’s and don’ts when installing a heat flux measure heat flux.
    [Show full text]
  • Heat Transfer
    CHAPTER 3 HEAT TRANSFER Heat Transfer Processes ........................................................... 3.1 Overall Heat Transfer Coefficient............................................ 3.18 Thermal Conduction ................................................................. 3.2 Heat Transfer Augmentation ................................................... 3.19 Thermal Radiation .................................................................... 3.8 Heat Exchangers ..................................................................... 3.28 Thermal Convection ................................................................ 3.13 Symbols ................................................................................... 3.34 EAT transfer is energy in transit because of a temperature dif- Fourier’s law for conduction is Hference. The thermal energy is transferred from one region to another by three modes of heat transfer: conduction, radiation, and ∂t q″ = –k----- (1a) convection. Heat transfer is among a group of energy transport phe- ∂x nomena that includes mass transfer (see Chapter 5), momentum transfer (see Chapter 2), and electrical conduction. Transport phe- where nomena have similar rate equations, in which flux is proportional to q″ = heat flux (heat transfer rate per unit area A), Btu/h·ft2 a potential difference. In heat transfer by conduction and convec- ∂t/∂x = temperature gradient, °F/ft tion, the potential difference is the temperature difference. Heat, k=thermal conductivity, Btu/h·ft2·°F mass, and momentum transfer are
    [Show full text]