USESI 691453 Catalog.Pdf
Total Page:16
File Type:pdf, Size:1020Kb
Tech at-a-Glance Flammability Ratings for Copper Cables Cable jacket ratings for copper cabling combine a wide range of terms, some of which may be more common than others depending upon location: CMX, CM, CMG, CMR and CMP. Jacket Types Per NFPA-70, the National Electric Code (NEC article 500), identifies the location where each cable type is to be used. • CMP (PLENUM): Suitable for use in ducts, plenums, and other spaces used for environmental air and shall also be listed as having adequate fire-resistant and low smoke-producing characteristics. These cables are also referenced in Canadian Standards as CSA FT6. • CMR (RISER): Suitable for use in a vertical run in a shaft or from floor to floor and shall also be listed as having fire-resistant characteristics capable of preventing the carrying of fire from floor to floor. • CMG (GENERAL PURPOSE): Suitable for general-purpose communications use, with the exception of risers and plenums, and shall also be listed as being resistant to the spread of fire. These cables are also referenced in Canadian Standards as CSA FT4. • CM (GENERAL PURPOSE): Suitable for general-purpose communications use, with the exception of risers and plenums, and shall also be listed as being resistant to the spread of fire. These cables are also referenced in Canadian Standards as CSA FT4. • CMX (LIMITED USE): Suitable for use in dwellings and for use in raceway and shall also be listed as being resistant to flame spread. As the flammability and smoke requirements for cables become more rigorous from CMX to CMP, the NEC also offers a cable substitution hierarchy (see Figure 1) to allow the use of more stringent requirement cables in place of a less rigid cable. For instance, a CMR or CMP cable could be replaced for a CM or CMG cable. DESCRIPTION TYPE TEST METHOD Plenum CMP NFPA 262-2007 Riser CMR UL 1666-2002 General Purpose CMG/CM UL 1685-2000* or CSA C22.2 No. 0.3-M-2001 *UL1685-2000 applies to CM cable only Limited Use CMX UL1581-2001 (VW-1 Flame Test) A Cable A shall be permitted to be used in place of cable B Figure 1: NEC Cable Substitution Hierarchy B 2 www.vericomsolutions.com Table of Contents Bulk Wire Installation Supplies Category Cable 4-13 Boots & Connectors 50,51 Coaxial Cable 14-18 Mounting & Hardware 51 Fire Alarm Cable 19,20 Tools & Testers 52 Irrigation & Control Wire 21,22 Wire Management 53 Media Cable 23,24 Security Cable 25-29 Power Products Speaker Cable 30 Power Adapters 54,55 Thermostat Cable 31-33 Power Cords 56 Cables & Adapters Surge Protectors 56 Audio / Video Cables 34 Racks, Cabinets & Accessories Coaxial Cables 35 Relay Racks 57-59 Ethernet Cables 36-38 Wall Mount Cabinets 60,61 USB Cables 39 Floor Cabinets 62-64 HDMI Cables 40,41 Cabinet & Rack Feature Comparison 65 Adapters 42,43 Cabinet & Rack Accessories 66-76 Flat Panel TV Mounts Splitters Low Profile TV Mounts 44 Splitters 900 MHz 77 Tilting TV Mounts 45 Splitters 3000 MHz 77 Full Motion TV Mounts 46,47 Desk & Ceiling Mounts 48 Wall Plates Grounding Products Decora Style Wall Plates & Kits 78 Keystone Wall Plates & Inserts 79 Ground Wire 49 Keystone Inserts 80 Grounding Supplies 49 Standard Wall Plates 81 Midsize Wall Plates 82 Surface Mounts 83 Although Vericom makes every reasonable effort to ensure their accuracy at the time of this publication, information, images and specifications herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. 865.671.4455 3 Category Cable CAT3 2P Unshielded CM Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange Available Put-Ups ∙1000’ Pull Box Available Colors Applications • 10BASE-T Networks • Telecommunications • Indoor *Colors are for representative purposes only. Actual product hues may vary. • Commercial/Residential SPECIFICATIONS Compliances Cable Construction 24 AWG U/UTP x 2P Jacket Type CM • RoHS Compliant Conductor Material SBC Overall Temp. Rating 75° C • ISO/IEC 11801 Insulation Material HDPE Voltage Rating 300 V • TIA/EIA-568-C.2 Ripcord Yes Impedence 1-16 MHz 100 ± 15 Ω Features Jacket Material PVC • Tested To 100 MHz STANDARDS COMPLIANCE • Twisted Pairs To Reduce Crosstalk RoHS Compliant ISO/IEC 11801 TIA/EIA 568-C.2 Category 3 Cable • Easy to Use Pull Box AVAILABILITY • Footage Markers on Cable Jacket ITEM # AVAILABLE COLOR • Colors: Gray and Beige MBW3U-01633 Gray MBW3U-03580 Beige BULK WIRE CAT3 3P Unshielded CM Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange P3 White-Green / Green Available Put-Ups ∙1000’ Pull Box Available Colors Applications • 10BASE-T Networks • Telecommunications • Indoor *Colors are for representative purposes only. Actual product hues may vary. • Commercial/Residential SPECIFICATIONS Compliances Cable Construction 24 AWG U/UTP x 3P Jacket Type CM • RoHS Compliant Conductor Material SBC Overall Temp. Rating 75° C • ISO/IEC 11801 Insulation Material HDPE Voltage Rating 300 V • TIA/EIA-568-C.2 Ripcord Yes Impedence 1-16 MHz 100 ± 15 Ω Features Jacket Material PVC • Tested To 100 MHz STANDARDS COMPLIANCE • Twisted Pairs To Reduce Crosstalk RoHS Compliant ISO/IEC 11801 TIA/EIA 568-C.2 Category 3 Cable • Easy to Use Pull Box AVAILABILITY • Footage Markers on Cable Jacket ITEM # AVAILABLE COLOR • Color: Gray MBW3U-04141 Gray 4 www.vericomsolutions.com Category Cable CAT5e Unshielded CM Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange P3 White-Green / Green P4 White-Brown / Brown Available Put-Ups ∙1000’ Pull Box Applications Available Colors • 10/100/1000BASE-T Networks • Telecommunications • LAN *Colors are for representative purposes only. • Indoor Actual product hues may vary. • Commercial/Residential SPECIFICATIONS Compliances Cable Construction 24 AWG U/UTP x 4P Jacket Type CM • c(UL)us Listed Conductor Material SBC Overall Temp. Rating 75° C • RoHS Compliant Insulation Material HDPE Voltage Rating 300 V • ISO/IEC 11801 Ripcord Yes Impedence 1-350 MHz 100 ± 15 Ω • TIA/EIA-568-C.2 Jacket Material PVC Features STANDARDS COMPLIANCE • Tested to 350 MHz c(UL)us Listed RoHS Compliant ISO/IEC 11801 TIA/EIA 568-C.2 Category 5e Cable • Twisted Pairs to Reduce Crosstalk AVAILABILITY • Easy to Use Pull Box ITEM # AVAILABLE COLOR • Footage Markers on Cable Jacket MBW5U-01531 Blue • Colors: Blue CAT5e Unshielded ETL Listed CMR Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange BULK WIRE P3 White-Green / Green P4 White-Brown / Brown Available Put-Ups ∙1000’ Pull Box Applications Available Colors • 10/100/1000BASE-T Networks • Telecommunications • LAN *Colors are for representative purposes only. • Indoor Actual product hues may vary. • Commercial/Residential SPECIFICATIONS Compliances Cable Construction 24 AWG U/UTP x 4P Jacket Type CMR • ETL Listed Type CMR Conductor Material SBC Overall Temp. Rating 75° C • ETL Verified Insulation Material HDPE Voltage Rating 300 V • RoHS Compliant Ripcord Yes Impedence 1-350 MHz 100 ± 15 Ω • ISO/IEC 11801 Jacket Material FRPVC • TIA/EIA-568-C.2 STANDARDS COMPLIANCE Features ETL Listed / Verified RoHS Compliant ISO/IEC 11801 TIA/EIA 568-C.2 Category 5e Cable • Tested to 350 MHz AVAILABILITY • Twisted Pairs to Reduce Crosstalk ITEM # AVAILABLE COLOR • Easy to Use Pull Box XBW5U-03596 Blue • Footage Markers on Cable Jacket XBW5U-03597 White • Colors: Blue and White 865.671.4455 5 Category Cable CAT5e Unshielded CMR Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange P3 White-Green / Green P4 White-Brown / Brown Available Put-Ups ∙1000’ Pull Box Available Colors Applications • 10/100/1000BASE-T Networks • Telecommunications • LAN *Colors are for representative purposes only. Actual product hues may vary. • Indoor • Commercial/Residential SPECIFICATIONS Cable Construction 24 AWG U/UTP x 4P Jacket Type CMR Compliances Conductor Material SBC Overall Temp. Rating 75° C • UL Listed Type CMR Insulation Material HDPE Voltage Rating 300 V • c(UL)us Listed • RoHS Compliant Ripcord Yes Impedence 1-350 MHz 100 ± 15 Ω • ISO/IEC 11801 Jacket Material FRPVC • TIA/EIA-568-C.2 STANDARDS COMPLIANCE c(UL)us Listed RoHS Compliant ISO/IEC 11801 TIA/EIA 568-C.2 Category 5e Cable Features AVAILABILITY • Tested to 350 MHz • Twisted Pairs to Reduce Crosstalk ITEM # AVAILABLE COLOR ITEM # AVAILABLE COLOR • Easy to Use Pull Box MBW5U-01440 Black MBW5U-03751 Orange • Footage Markers on Cable Jacket MBW5U-00932 Blue MBW5U-01554 Red • Colors: Multiple Available BULK WIRE MBW5U-01442 Gray MBW5U-01441 White MBW5U-01555 Green MBW5U-01443 Yellow CAT5e Shielded CMR Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange P3 White-Green / Green P4 White-Brown / Brown Available Put-Ups ∙1000’ Pull Box Available Colors Applications • 10/100/1000BASE-T Networks • Telecommunications • LAN *Colors are for representative purposes only. Actual product hues may vary. • Indoor • Commercial/Residential SPECIFICATIONS Cable Construction 24 AWG U/UTP x 4P Ripcord Yes Compliances Conductor Material SBC Jacket Material FRPVC • UL Listed Type CMR Insulation Material HDPE Jacket Type CMR • c(UL)us Listed • RoHS Compliant Core Wrap PE Tape Overall Temp. Rating 75° C • ISO/IEC 11801 Shielding Material Aluminum Foil Voltage Rating 300 V • TIA/EIA-568-C.2 Drain Wire Diameter 0.40 mm Impedence 1-350 MHz 100 ± 15 Ω STANDARDS COMPLIANCE Features c(UL)us Listed RoHS Compliant ISO/IEC 11801 TIA/EIA 568-C.2 Category 5e Cable • Shielded to Reduce EMI • Tested to 350 MHz AVAILABILITY • Twisted Pairs to Reduce Crosstalk ITEM # AVAILABLE COLOR • Easy to Use Pull Box MBW5F-00933 Blue • Footage Markers on Cable Jacket • Color: Blue 6 www.vericomsolutions.com Category Cable CAT5e Unshielded CMX Indoor / Outdoor Premise Cable P1 White-Blue / Blue P2 White-Orange / Orange P3 White-Green / Green P4 White-Brown / Brown Available Put-Ups ∙1000’ Pull Box Applications Available Colors • 10/100/1000BASE-T Networks • Telecommunications • LAN *Colors are for representative purposes only.