Mise En Pratique for the Definition of the Kilogram in the SI
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Units and Conversions
Units and Conversions This unit of the Metrology Fundamentals series was developed by the Mitutoyo Institute of Metrology, the educational department within Mitutoyo America Corporation. The Mitutoyo Institute of Metrology provides educational courses and free on-demand resources across a wide variety of measurement related topics including basic inspection techniques, principles of dimensional metrology, calibration methods, and GD&T. For more information on the educational opportunities available from Mitutoyo America Corporation, visit us at www.mitutoyo.com/education. This technical bulletin addresses an important aspect of the language of measurement – the units used when reporting or discussing measured values. The dimensioning and tolerancing practices used on engineering drawings and related product specifications use either decimal inch (in) or millimeter (mm) units. Dimensional measurements are therefore usually reported in either of these units, but there are a number of variations and conversions that must be understood. Measurement accuracy, equipment specifications, measured deviations, and errors are typically very small numbers, and therefore a more practical spoken language of units has grown out of manufacturing and precision measurement practice. Metric System In the metric system (SI or International System of Units), the fundamental unit of length is the meter (m). Engineering drawings and measurement systems use the millimeter (mm), which is one thousandths of a meter (1 mm = 0.001 m). In general practice, however, the common spoken unit is the “micron”, which is slang for the micrometer (m), one millionth of a meter (1 m = 0.001 mm = 0.000001 m). In more rare cases, the nanometer (nm) is used, which is one billionth of a meter. -
An Atomic Physics Perspective on the New Kilogram Defined by Planck's Constant
An atomic physics perspective on the new kilogram defined by Planck’s constant (Wolfgang Ketterle and Alan O. Jamison, MIT) (Manuscript submitted to Physics Today) On May 20, the kilogram will no longer be defined by the artefact in Paris, but through the definition1 of Planck’s constant h=6.626 070 15*10-34 kg m2/s. This is the result of advances in metrology: The best two measurements of h, the Watt balance and the silicon spheres, have now reached an accuracy similar to the mass drift of the ur-kilogram in Paris over 130 years. At this point, the General Conference on Weights and Measures decided to use the precisely measured numerical value of h as the definition of h, which then defines the unit of the kilogram. But how can we now explain in simple terms what exactly one kilogram is? How do fixed numerical values of h, the speed of light c and the Cs hyperfine frequency νCs define the kilogram? In this article we give a simple conceptual picture of the new kilogram and relate it to the practical realizations of the kilogram. A similar change occurred in 1983 for the definition of the meter when the speed of light was defined to be 299 792 458 m/s. Since the second was the time required for 9 192 631 770 oscillations of hyperfine radiation from a cesium atom, defining the speed of light defined the meter as the distance travelled by light in 1/9192631770 of a second, or equivalently, as 9192631770/299792458 times the wavelength of the cesium hyperfine radiation. -
Consultative Committee for Amount of Substance; Metrology in Chemistry and Biology CCQM Working Group on Isotope Ratios (IRWG) S
Consultative Committee for Amount of Substance; Metrology in Chemistry and Biology CCQM Working Group on Isotope Ratios (IRWG) Strategy for Rolling Programme Development (2021-2030) 1. EXECUTIVE SUMMARY In April 2017, the Consultative Committee for Amount of Substance; Metrology in Chemistry and Biology (CCQM) established a task group to study the metrological state of isotope ratio measurements and to formulate recommendations to the Consultative Committee (CC) regarding potential engagement in this field. In April 2018 the Isotope Ratio Working Group (IRWG) was established by the CCQM based on the recommendation of the task group. The main focus of the IRWG is on the stable isotope ratio measurement science activities needed to improve measurement comparability to advance the science of isotope ratio measurement among National Metrology Institutes (NMIs) and Designated Institutes (DIs) focused on serving stake holder isotope ratio measurement needs. During the current five-year mandate, it is expected that the IRWG will make significant advances in: i. delta scale definition, ii. measurement comparability of relative isotope ratio measurements, iii. comparable measurement capabilities for C and N isotope ratio measurement; and iv. the understanding of calibration modalities used in metal isotope ratio characterization. 2. SCIENTIFIC, ECONOMIC AND SOCIAL CHALLENGES Isotopes have long been recognized as markers for a wide variety of molecular processes. Indeed, applications where isotope ratios are used provide scientific, economic, and social value. Early applications of isotope measurements were recognized with the 1943 Nobel Prize for Chemistry which included the determination of the water content in the human body, determination of solubility of various low-solubility salts, and development of the isotope dilution method which has since become the cornerstone of analytical chemistry. -
Guide for the Use of the International System of Units (SI)
Guide for the Use of the International System of Units (SI) m kg s cd SI mol K A NIST Special Publication 811 2008 Edition Ambler Thompson and Barry N. Taylor NIST Special Publication 811 2008 Edition Guide for the Use of the International System of Units (SI) Ambler Thompson Technology Services and Barry N. Taylor Physics Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 (Supersedes NIST Special Publication 811, 1995 Edition, April 1995) March 2008 U.S. Department of Commerce Carlos M. Gutierrez, Secretary National Institute of Standards and Technology James M. Turner, Acting Director National Institute of Standards and Technology Special Publication 811, 2008 Edition (Supersedes NIST Special Publication 811, April 1995 Edition) Natl. Inst. Stand. Technol. Spec. Publ. 811, 2008 Ed., 85 pages (March 2008; 2nd printing November 2008) CODEN: NSPUE3 Note on 2nd printing: This 2nd printing dated November 2008 of NIST SP811 corrects a number of minor typographical errors present in the 1st printing dated March 2008. Guide for the Use of the International System of Units (SI) Preface The International System of Units, universally abbreviated SI (from the French Le Système International d’Unités), is the modern metric system of measurement. Long the dominant measurement system used in science, the SI is becoming the dominant measurement system used in international commerce. The Omnibus Trade and Competitiveness Act of August 1988 [Public Law (PL) 100-418] changed the name of the National Bureau of Standards (NBS) to the National Institute of Standards and Technology (NIST) and gave to NIST the added task of helping U.S. -
Role of Metrology in Conformity Assessment
Role of Metrology in Conformity Assessment Andy Henson Director of International Liaison and Communications of the BIPM Metrology, the science of measurement… and its applications “When you can measure what you are speaking about, and express it in numbers, you know something about it; but when you cannot express it in numbers, your knowledge is of a meagre and unsatisfactory kind” William Thompson (Lord Kelvin): Lecture on "Electrical Units of Measurement" (3 May 1883) Conformity assessment Overall umbrella of measures taken by : ‐manufacturers ‐customers ‐regulatory authorities ‐independent third parties To assess that a product/service meets standards or technical regulations 2 Metrology is a part of our lives from birth Best regulation Safe food Technical evidence Safe treatment Safe baby food Manufacturing Safe traveling Globalization weighing of baby Healthcare Innovation Climate change Without metrology, you can’t discover, design, build, test, manufacture, maintain, prove, buy or operate anything safely and reliably. From filling your car with petrol to having an X‐ray at a hospital, your life is surrounded by measurements. In industry, from the thread of a nut and bolt and the precision machined parts on engines down to tiny structures on micro and nano components, all require an accurate measurement that is recognized around the world. Good measurement allows country to remain competitive, trade throughout the world and improve quality of life. www.bipm.org 3 Metrology, the science of measurement As we have seen, measurement science is not purely the preserve of scientists. It is something of vital importance to us all. The intricate but invisible network of services, suppliers and communications upon which we are all dependent rely on metrology for their efficient and reliable operation. -
Measuring in Metric Units BEFORE Now WHY? You Used Metric Units
Measuring in Metric Units BEFORE Now WHY? You used metric units. You’ll measure and estimate So you can estimate the mass using metric units. of a bike, as in Ex. 20. Themetric system is a decimal system of measurement. The metric Word Watch system has units for length, mass, and capacity. metric system, p. 80 Length Themeter (m) is the basic unit of length in the metric system. length: meter, millimeter, centimeter, kilometer, Three other metric units of length are themillimeter (mm) , p. 80 centimeter (cm) , andkilometer (km) . mass: gram, milligram, kilogram, p. 81 You can use the following benchmarks to estimate length. capacity: liter, milliliter, kiloliter, p. 82 1 millimeter 1 centimeter 1 meter thickness of width of a large height of the a dime paper clip back of a chair 1 kilometer combined length of 9 football fields EXAMPLE 1 Using Metric Units of Length Estimate the length of the bandage by imagining paper clips laid next to it. Then measure the bandage with a metric ruler to check your estimate. 1 Estimate using paper clips. About 5 large paper clips fit next to the bandage, so it is about 5 centimeters long. ch O at ut! W 2 Measure using a ruler. A typical metric ruler allows you to measure Each centimeter is divided only to the nearest tenth of into tenths, so the bandage cm 12345 a centimeter. is 4.8 centimeters long. 80 Chapter 2 Decimal Operations Mass Mass is the amount of matter that an object has. The gram (g) is the basic metric unit of mass. -
The Kelvin and Temperature Measurements
Volume 106, Number 1, January–February 2001 Journal of Research of the National Institute of Standards and Technology [J. Res. Natl. Inst. Stand. Technol. 106, 105–149 (2001)] The Kelvin and Temperature Measurements Volume 106 Number 1 January–February 2001 B. W. Mangum, G. T. Furukawa, The International Temperature Scale of are available to the thermometry commu- K. G. Kreider, C. W. Meyer, D. C. 1990 (ITS-90) is defined from 0.65 K nity are described. Part II of the paper Ripple, G. F. Strouse, W. L. Tew, upwards to the highest temperature measur- describes the realization of temperature able by spectral radiation thermometry, above 1234.93 K for which the ITS-90 is M. R. Moldover, B. Carol Johnson, the radiation thermometry being based on defined in terms of the calibration of spec- H. W. Yoon, C. E. Gibson, and the Planck radiation law. When it was troradiometers using reference blackbody R. D. Saunders developed, the ITS-90 represented thermo- sources that are at the temperature of the dynamic temperatures as closely as pos- equilibrium liquid-solid phase transition National Institute of Standards and sible. Part I of this paper describes the real- of pure silver, gold, or copper. The realiza- Technology, ization of contact thermometry up to tion of temperature from absolute spec- 1234.93 K, the temperature range in which tral or total radiometry over the tempera- Gaithersburg, MD 20899-0001 the ITS-90 is defined in terms of calibra- ture range from about 60 K to 3000 K is [email protected] tion of thermometers at 15 fixed points and also described. -
Handbook of MASS MEASUREMENT
Handbook of MASS MEASUREMENT FRANK E. JONES RANDALL M. SCHOONOVER CRC PRESS Boca Raton London New York Washington, D.C. © 2002 by CRC Press LLC Front cover drawing is used with the consent of the Egyptian National Institute for Standards, Gina, Egypt. Back cover art from II Codice Atlantico di Leonardo da Vinci nella Biblioteca Ambrosiana di Milano, Editore Milano Hoepli 1894–1904. With permission from the Museo Nazionale della Scienza e della Tecnologia Leonardo da Vinci Milano. Library of Congress Cataloging-in-Publication Data Jones, Frank E. Handbook of mass measurement / Frank E. Jones, Randall M. Schoonover p. cm. Includes bibliographical references and index. ISBN 0-8493-2531-5 (alk. paper) 1. Mass (Physics)—Measurement. 2. Mensuration. I. Schoonover, Randall M. II. Title. QC106 .J66 2002 531’.14’0287—dc21 2002017486 CIP This book contains information obtained from authentic and highly regarded sources. Reprinted material is quoted with permission, and sources are indicated. A wide variety of references are listed. Reasonable efforts have been made to publish reliable data and information, but the author and the publisher cannot assume responsibility for the validity of all materials or for the consequences of their use. Neither this book nor any part may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, microfilming, and recording, or by any information storage or retrieval system, without prior permission in writing from the publisher. The consent of CRC Press LLC does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific permission must be obtained in writing from CRC Press LLC for such copying. -
MEMS Metrology Metrology What Is a Measurement Measurable
Metrology • What is metrology? – It is the science of weights and measures • Refers primarily to the measurements of length, MEMS Metrology wetight, time, etc. • Mensuration- A branch of applied geometry – It measure the area and volume of solids from Dr. Bruce K. Gale lengths and angles Fundamentals of Micromachining • It also includes other engineering measurements for the establishment of a flat, plane reference surface What is a Measurement Measurable Parameters • A measurement is an act of assigning a • What do we want to • Pressure specific value to a physical variable measure? • Forces • The physical variable becomes the • Length or distance •Stress measured variable •Mass •Strain • Temperature • Measurements provide a basis for • Friction judgements about • Elemental composition • Resistance •Viscosity – Process information • Roughness • Diplacements or – Quality assurance •Depth distortions – Process control • Intensity •Time •etc. Components of a Measuring Measurement Systems and Tools System • Measurement systems are important tools for the quantification of the physical variable • Measurement systems extend the abilities of the human senses, while they can detect and recognize different degrees of physical variables • For scientific and engineering measurement, the selection of equipment, techniques and interpretation of the measured data are important How Important are Importance of Metrology Measurements? • In human relationships, things must be • Measurement is the language of science counted and measured • It helps us -
The Kibble Balance and the Kilogram
C. R. Physique 20 (2019) 55–63 Contents lists available at ScienceDirect Comptes Rendus Physique www.sciencedirect.com The new International System of Units / Le nouveau Système international d’unités The Kibble balance and the kilogram La balance de Kibble et le kilogramme ∗ Stephan Schlamminger , Darine Haddad NIST, 100 Bureau Drive, Gaithersburg, MD 20899, USA a r t i c l e i n f o a b s t r a c t Article history: Dr. Bryan Kibble invented the watt balance in 1975 to improve the realization of the unit Available online 25 March 2019 for electrical current, the ampere. With the discovery of the Quantum Hall effect in 1980 by Dr. Klaus von Klitzing and in conjunction with the previously predicted Josephson effect, Keywords: this mechanical apparatus could be used to measure the Planck constant h. Following a Unit of mass proposal by Quinn, Mills, Williams, Taylor, and Mohr, the Kibble balance can be used to Kilogram Planck constant realize the unit of mass, the kilogram, by fixing the numerical value of Planck’s constant. Kibble balance In 2017, the watt balance was renamed to the Kibble balance to honor the inventor, who Revised SI passed in 2016. This article explains the Kibble balance, its role in the redefinition of the Josephson effect unit of mass, and attempts an outlook of the future. Quantum Hall effect Published by Elsevier Masson SAS on behalf of Académie des sciences. This is an open access article under the CC BY-NC-ND license Mots-clés : (http://creativecommons.org/licenses/by-nc-nd/4.0/). -
Thermometry (Temperature Measurement)
THERMOMETRY Thermometry ................................................................................................................................................. 1 Applications .............................................................................................................................................. 2 Temperature metrology ............................................................................................................................. 2 The primary standard: the TPW-cell ..................................................................................................... 5 Temperature and the ITS-90 ..................................................................................................................... 6 The Celsius scale ................................................................................................................................... 6 Thermometers and thermal baths .......................................................................................................... 7 Metrological properties ............................................................................................................................. 7 Types of thermometers.............................................................................................................................. 9 Liquid-in-glass ...................................................................................................................................... 9 Thermocouple .................................................................................................................................... -
Time-Reversal-Based Quantum Metrology with Many-Body Entangled States
Time-Reversal-Based Quantum Metrology with Many-Body Entangled States 1 1 1 Simone Colombo, ∗ Edwin Pedrozo-Penafiel,˜ ∗ Albert F. Adiyatullin, ∗ Zeyang Li,1 Enrique Mendez,1 Chi Shu,1;2 Vladan Vuletic´1 1Department of Physics, MIT-Harvard Center for Ultracold Atoms and Research Laboratory of Electronics, Massachusetts Institute of Technology, 2Department of Physics, Harvard University Cambridge, Massachusetts 02139, USA ∗These authors contributed equally to this work In quantum metrology, entanglement represents a valuable resource that can be used to overcome the Standard Quantum Limit (SQL) that bounds the precision of sensors that operate with independent particles. Measurements beyond the SQL are typically enabled by relatively simple entangled states (squeezed states with Gaussian probability distributions), where quantum noise is redistributed between different quadratures. However, due to both funda- arXiv:2106.03754v3 [quant-ph] 28 Sep 2021 mental limitations and the finite measurement resolution achieved in practice, sensors based on squeezed states typically operate far from the true fundamen- tal limit of quantum metrology, the Heisenberg Limit. Here, by implement- ing an effective time-reversal protocol through a controlled sign change in an optically engineered many-body spin Hamiltonian, we demonstrate atomic- sensor performance with non-Gaussian states beyond the limitations of spin 1 squeezing, and without the requirement of extreme measurement resolution. Using a system of 350 neutral 171Yb atoms, this signal amplification through time-reversed interaction (SATIN) protocol achieves the largest sensitivity im- provement beyond the SQL (11:8 0:5 dB) demonstrated in any (full Ramsey) ± interferometer to date. Furthermore, we demonstrate a precision improving in proportion to the particle number (Heisenberg scaling), at fixed distance of 12.6 dB from the Heisenberg Limit.