Electrical Abbreviations Enclosed Disconnect Switch Legend Electrical Drawing List

Total Page:16

File Type:pdf, Size:1020Kb

Electrical Abbreviations Enclosed Disconnect Switch Legend Electrical Drawing List ELECTRICAL ABBREVIATIONS ENCLOSED DISCONNECT SWITCH LEGEND ELECTRICAL DRAWING LIST SYMBOL DESCRIPTION DRAWING SCALE DESCRIPTION ENCLOSED NON-FUSED DISCONNECT SWITCH. DSx INDICATES SWITCH NUMBER; A AMPERE DIST DISTRIBUTION kA KILOAMPERE SCWR SHORT CIRCUIT WITHSTAND RATING REFER TO ENCLOSED DISCONNECT SWITCH SCHEDULE BELOW FOR RATINGS. E-001 NO SCALE ELECTRICAL LEGEND SHEET AC ALTERNATING CURRENT DS DISCONNECT SWITCH kAIC KILOAMPERE INTERRUPTING CAPACITY SEC SECONDARY DSx SWITCHES SHOWN ON PLANS WITHOUT SWITCH NUMBER INDICATED ARE TYPE DS2. ACB AIR CIRCUIT BREAKER DWG DRAWING kcmil THOUSAND CIRCULAR MILS SMR SURFACE-MOUNTED RACEWAY E-201 1/4"=1'-0" ELECTRICAL NEW WORK PLANS ADA AMERICANS WITH DISABILITIES ACT kV KILOVOLT SPD SURGE PROTECTION DEVICE AF AMP FRAME E EMERGENCY kVA KILOVOLT-AMPERE SPDT SINGLE-POLE DOUBLE-THROW ENCLOSED FUSED DISCONNECT SWITCH. FSx INDICATES SWITCH NUMBER; REFER TO ENCLOSED DISCONNECT SWITCH SCHEDULE BELOW FOR RATINGS. E-301 NO SCALE SINGLE-LINE DIAGRAM AFC ABOVE FINISH CEILING EF EXHAUST FAN kW KILOWATT SPST SINGLE-POLE SINGLE-THROW FSx AFF ABOVE FINISHED FLOOR ELEC ELECTRICAL ST SHUNT-TRIP SWITCHES SHOWN ON PLANS WITHOUT SWITCH NUMBER INDICATED ARE TYPE FS2. AFG ABOVE FINISHED GRADE ELEV ELEVATOR LA LIGHTNING ARRESTOR STBY STANDBY AHU AIR HANDLING UNIT EM EMERGENCY LPS LIGHTNING PROTECTION SYSTEM SW SWITCH AIC AMPERE INTERRUPTING CAPACITY EMT ELECTRICAL METALLIC TUBING LTG LIGHTING SWBD SWITCHBOARD AL ALUMINUM ENCL ENCLOSURE SWGR SWITCHGEAR ENCLOSED DISCONNECT SWITCH SCHEDULE AM AMMETER EO ELECTRICALLY-OPERATED MAX MAXIMUM SYS SYSTEM AMP AMPERE EQPT EQUIPMENT MCB MAIN CIRCUIT BREAKER ARCH ARCHITECT EWC ELECTRIC WATER COOLER MCC MOTOR CONTROL CENTER T/D TELEPHONE/DATA NON-FUSED SWITCHES FUSED SWITCHES ARCS AREA OF REFUGE COMMUNICATION SYSTEM MCCB MOLDED-CASE CIRCUIT BREAKER TEL TELEPHONE RATINGS RATINGS AT AMP TRIP F FUSE MCP MOTOR CIRCUIT PROTECTOR TL TWIST-LOCK SWITCH SWITCH ATS AUTOMATIC TRANSFER SWITCH FA FIRE ALARM MECH MECHANICAL TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION NUMBER VOLTAGE AMPERAGE POLES NUMBER VOLTAGE AMPERAGE POLES AUX AUXILIARY FACP FIRE ALARM CONTROL PANEL MH MANHOLE TYP TYPICAL DS1 600 30 2 FS1 600 30 2 FCB FUSED CIRCUIT BREAKER MIN MINIMUM DS2 600 30 3 FS2 600 30 3 BAS BUILDING AUTOMATION SYSTEM FDR FEEDER MLO MAIN LUGS ONLY UC UNDERCOUNTER DS3 600 30 6 FS3 600 30 6 BC BRANCH CIRCUIT FLA FULL LOAD AMPS MTD MOUNTED UPS UNINTERRUPTIBLE POWER SUPPLY BKR BREAKER FRAP FIRE ALARM REMOTE ANNUNCIATOR PANEL DS4 600 60 3 FS4 600 60 3 BLDG BUILDING FS FUSED DISCONNECT SWITCH N NEUTRAL V VOLT DS5 600 60 6 FS5 600 60 6 GENERAL ELECTRICAL NOTES FTL FEED-THROUGH LUGS NC NORMALLY-CLOSED VA VOLT-AMPERE DS6 600 100 3 FS6 600 100 3 C CONDUIT FVNR FULL-VOLTAGE NON-REVERSING NL NIGHT LIGHT VCB VACUUM CIRCUIT BREAKER DS7 600 100 6 FS7 600 100 6 CB CIRCUIT BREAKER NO NORMALLY-OPEN VFC VARIABLE FREQUENCY CONTROLLER CCTV CLOSED CIRCUIT TELEVISION G GROUND NTS NOT TO SCALE DS8 600 200 3 FS8 600 200 3 1. WORK SHOWN ON THESE PLANS IS NEW UNLESS NOTED OTHERWISE. CFL COMPACT FLUORESCENT LAMP GEC GROUNDING ELECTRODE CONDUCTOR W WATT OR WIRE DS9 600 200 6 FS9 600 200 6 2. COMPONENTS SHOWN ON THE RISER DIAGRAMS, BUT NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED CIR CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPTER OC ON-CENTER Wh WATTHOUR DS10 600 400 3 FS10 600 400 3 CL CENTERLINE GFEP GROUND FAULT EQUIPMENT PROTECTION OCPD OVERCURRENT PROTECTION DEVICE WhM AS IF SHOWN ON BOTH. WATTHOUR METER DS11 600 600 3 FS11 600 600 3 CLF CURRENT LIMITING FUSE GRS GALVANIZED RIGID STEEL CONDUIT WM WATTMETER CLG CEILING P POLE WP WEATHER-PROOF DS12 600 800 3 FS12 600 800 3 3. PROVIDE ELECTRICAL CONNECTIONS FOR EQUIPMENT SHOWN ON CONTRACT DOCUMENTS OF OTHER TRADES. COMM COMMUNICATIONS HACR HEATING, AIR CONDITIONING, REFRIGERATION PA PUBLIC ADDRESS WT WATER-TIGHT REFER TO THOSE DOCUMENTS TO DETERMINE ELECTRICAL CONNECTION REQUIREMENTS AND MOUNTING CONN CONNECTION HOA HAND-OFF-AUTOMATIC PB PUSHBUTTON NOTES: LOCATIONS FOR EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. PNL CPT CONTROL POWER TRANSFORMER HP HORSEPOWER PANEL OR PANELBOARD XFER TRANSFER 1. SWITCH NUMBERS ARE GENERAL DESIGNATIONS TO INDICATE SWITCH TYPE AND DO NOT INDICATE A UNIQUE IDENTIFIER. PRI XFMR Cu COPPER PRIMARY TRANSFORMER REFER TO PLAN DRAWINGS FOR QUANTITIES OF EACH SWITCH TYPE REQUIRED. 4. EXAMINE CONDITIONS UNDER WHICH WORK MUST BE PERFORMED PRIOR TO COMMENCEMENT OF WORK. CT CURRENT TRANSFORMER IC INTERRUPTING CAPACITY PT POTENTIAL TRANSFORMER REPORT ADVERSE CONDITIONS IN WRITING TO OWNER. COMMENCEMENT OF WORK SHALL BE CONSTRUED AS ICCB INSULATED-CASE CIRCUIT BREAKER PWR POWER XP EXPLOSION-PROOF 2. LOCATE DISCONNECT SWITCHES AS CLOSE AS PRACTICABLE TO EQUIPMENT SERVED, AND IN ACCORDANCE WITH THE COMPLETE ACCEPTANCE OF EXISTING CONDITIONS INCLUDING PREPARATORY WORK DONE BY OTHERS. DC DIRECT CURRENT IG ISOLATED GROUND NATIONAL ELECTRIC CODE. PROVIDE FINAL CONNECTIONS TO ASSOCIATED EQUIPMENT. DN DOWN RMC RIGID METAL CONDUIT 5. PERFORM WORK IN SUCH A WAY THAT ADJACENT AREAS ARE NOT DISRUPTED. PROVIDE NOISE, DUST, AND DISC DISCONNECT JB JUNCTION BOX RVS REDUCED-VOLTAGE STARTER 3. DISCONNECT SWITCHES SHALL BE RATED FOR THE MAXIMUM AVAILABLE FAULT CURRENT, AND SHALL BE RATED IN DIRT CONTROL BARRIERS AS REQUIRED. HORSEPOWER TO MEET THE REQUIREMENTS OF THE EQUIPMENT SERVED. 6. REFER TO ARCHITECTURAL CONTRACT DOCUMENTS FOR PROJECT PHASING, AND FOR MOUNTING HEIGHTS 4. DISCONNECT SWITCHES SHALL BE SERVICE-ENTRANCE RATED. AND LOCATIONS OF ELECTRICAL EQUIPMENT AND DEVICES. 5. COORDINATE EXACT FUSE SIZE FOR FUSED DISCONNECT SWITCHES WITH THE REQUIREMENTS OF EQUIPMENT SERVED. 7. ELECTRICAL COMPONENTS, DEVICES AND ACCESSORIES SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED 6. PROVIDE BUILT-IN FUSE PULLERS FOR FUSED DISCONNECT SWITCHES RATED 200A AND SMALLER. FOR INTENDED USE. FEEDER CIRCUIT SCHEDULE (600-VOLT COPPER CONDUCTORS) BRANCH CIRCUIT SCHEDULE (600-VOLT COPPER CONDUCTORS) 7. PROVIDE FULLY-RATED EQUIPMENT GROUND LUGS FOR EACH DISCONNECT SWITCH. 8. COMPLY WITH NFPA 70 AND ALL OTHER APPLICABLE CODES AND STANDARDS. 2w20 3/4"C, 2#12 & 1#12G 3/4"C, 2#10 & 1#10G 1"C, 2#8 & 1#8G 1"C, 2#6 & 1#6G 1-1/4"C, 2#4 & 1#4G 8. PROVIDE 100%-RATED NEUTRAL LUGS IN DISCONNECT SWITCHES FOR CIRCUITS THAT CONTAIN NEUTRAL CONDUCTORS. 9. DRAWINGS INDICATE MAXIMUM DIMENSIONS FOR ELECTRICAL COMPONENTS AND EQUIPMENT, INCLUDING 3w80 1-1/4"C, 3#3 & 1#6 G 4w80 1-1/2"C, 4#3 & 1#6 G 5w80 1-1/2"C, 5#3 & 1#6 G CLEARANCES BETWEEN ENCLOSURES, ADJACENT SURFACES AND OTHER ITEMS. COMPLY WITH INDICATED 3w20 3/4"C, 3#12 & 1#12G 3/4"C, 3#10 & 1#10G 1"C, 3#8 & 1#8G 1"C, 3#6 & 1#6G 1-1/4"C, 3#4 & 1#4G PROVIDE 200%-RATED NEUTRAL LUGS IN DISCONNECT SWITCHES FOR CIRCUITS THAT CONTAIN 200%-RATED NEUTRAL CONDUCTORS. MAXIMUM DIMENSIONS. 3w90 1-1/4"C, 3#2 & 1#6 G 4w90 1-1/2"C, 4#2 & 1#6 G 5w90 2"C, 5#2 & 1#6 G 4w20 3/4"C, 4#12 & 1#12G 3/4"C, 4#10 & 1#10G 1"C, 4#8 & 1#8G 1-1/4"C, 4#6 & 1#6G 1-1/2"C, 4#4 & 1#4G 10. INTERRUPTIONS TO EXISTING ELECTRIC SERVICES AND SYSTEMS SHALL BE AS SHORT AS POSSIBLE AND AT A 5w20 3/4"C, 5#12 & 1#12G 1"C, 5#10 & 1#10G 1-1/4"C, 5#8 & 1#8G 1-1/4"C, 5#6 & 1#6G 1-1/2"C, 5#4 & 1#4G 9. FOR DISCONNECT SWITCHES CONNECTED TO THE LOAD SIDE OF VARIABLE FREQUENCY CONTROLLERS, PROVIDE 3w100 4w100 5w100 TIME AND DURATION APPROVED BY THE OWNER. SYSTEMS FEEDERS AND BRANCH CIRCUITS WHICH PASS 1-1/2"C, 3#1 & 1#6 G 2"C, 4#1 & 1#6 G 2"C, 5#1 & 1#6 G AUXILIARY SWITCH CONTACTS AND INTERCONNECT WIRING IN CONDUIT BACK TO CONTROLLER TO PROHIBIT VFD 120V/1 3w110 4w110 5w110 ɐ CL 80ft 80ft < CL 130ft 130ft < CL 200ft 200ft < CL 320ft 320ft < CL 500ft OPERATION WHEN ASSOCIATED DISCONNECT SWITCH IS OPEN. THROUGH ALTERED AREAS AND SERVE OTHER AREAS SHALL BE MAINTAINED. 208V/1ɐ CL 140ft 140ft < CL 220ft 220ft < CL 350ft 350ft < CL 560ft 560ft < CL 900ft 3w125 2"C, 3#1/0 & 1#6 G 4w125 2"C, 4#1/0 & 1#6 G 5w125 2"C, 5#1/0 & 1#6 G 208V/3ɐ CL 280ft 280ft < CL 450ft 450ft < CL 700ft 700ft < CL 1150ft - 10. FOR DISCONNECT SWITCHES CONNECTED TO THE LINE SIDE OF ELEVATOR CONTROLLERS, PROVIDE AUXILIARY SWITCH 11. CUT, CHANNEL, CHASE, AND DRILL FLOORS, WALLS, PARTITIONS, CEILINGS, AND OTHER SURFACES REQUIRED TO FACILITATE ELECTRICAL INSTALLATIONS. REPAIR AND REFINISH DISTURBED FINISH MATERIALS AND OTHER 277V/1ɐ CL 180ft 180ft < CL 300ft 300ft < CL 470ft 470ft < CL 750ft 750ft < CL 1200ft CONTACTS AND INTERCONNECT WIRING IN CONDUIT BACK TO CONTROLLER TO PROHIBIT TRANSFER TO BATTERY WHEN 3w150 2"C, 3#1/0 & 1#4 G 4w150 2"C, 4#1/0 & 1#4 G 5w150 2"C, 5#1/0 & 1#4 G ASSOCIATED DISCONNECT SWITCH IS OPENED FOR MAINTENANCE. SURFACES TO MATCH ADJACENT UNDISTURBED FINISHES. PROVIDE FIREPROOFING WHERE EXISTING 480V/1ɐ CL 320ft 320ft < CL 520ft 520ft < CL 820ft 820ft < CL 1300ft - FIREPROOFING IS DISTURBED. ALL WORK SHALL BE PERFORMED BY SKILLED MECHANICS OF TRADES 480V/3ɐ CL 650ft 650ft < CL 1030ft - - - INVOLVED. COORDINATE ALL CUT/PATCH LOCATIONS WITH PM/ARCHITECT (CHECK DIVISION 1 REQUIREMENTS) 3w175 2"C, 3#2/0 & 1#4 G 4w175 2"C, 4#2/0 & 1#4 G 5w175 2-1/2"C, 5#2/0 & 1#4 G 11.
Recommended publications
  • Commercial and Industrial Wiring. INSTITUTION Mid-America Vocational Curriculum Consortium, Stillwater, Okla
    DOCUMENT RESUME ED 319 912 CE 054 850 AUTHOR Kaltwasser, Stan; Flowers, Gary TITLE Commercial and Industrial Wiring. INSTITUTION Mid-America Vocational Curriculum Consortium, Stillwater, Okla. PUB DATE 88 NOTE 710p.; For related documents, see CE 054 849 and CE 055 217. Printed on colored paper. AVAILABLE FROM Mid-America Vocational Curriculum Consortium, 1500 West Seventh Avenue, Stillwater, OK 74074 (order no. 801401: $19.00). PUB TYPE Guides - Classroom Use Guides (For Teachers)(052) EDRS PRICE MF04 Plus Postage. PC Not Available from EDRS. DESCRIPTORS Classroom Techniques; Construction (Process); Course Content; Curriculum Guides; Electrical Occupations; Electrical Systems; *Electric Circuits; *Electricity; *Entry Workers; *Job Skills; *Learning Activities; Learning Modules; Lesson Plans; Postsecondary Education; Secondary Education; Skill Development; Teaching Methods; Test Items; Units of Study IDENTIFIERS *Electrical Wiring ABSTRACT This module is the third in a series of three wiring publications, includes additional technical knowledge and applications required for job entry in the commercial and industrial wiring trade. The module contains 15 instructional units that cover the following topics: blueprint reading and load calculations; tools and equipment; service; transformers; rough-in; lighting; motors and controllers; electrical diagrams and symbols; two and three wire controls; separate control circuits; sequence control circuits; jogging controls; reversing starters; special control circuits; and programmable controls. A special supplement of practice situations is also provided. Each instructional unit follows a standard format that includes some or all of these eight basic components: performance objectives, suggested activities or teachers and students, information sheets, assignment sheets, job sheets, visual aids, tests, and answers to tests and assignment sheets. All of the unit components focus on measurable and observable learning outcomes and are designed for use for more than one lesson or class period.
    [Show full text]
  • Connecting to the Grid – Alberta's New Micro-Generation Regulations
    Connecting to the Grid – Alberta’s New Micro-Generation Regulations Solar Energy Society of Canada – Northern Alberta Chapter MacEwan College 2009 April 21 www.macewan.ca www.solaralberta.ca Gordon Howell, P.Eng. E-mail: [email protected] (download this presentation from www.hme.ca/presentations) Solar Energy Development Specialists 1 Alberta’s Micro-Generation Regulations 5.6 kW solar PV system Riverdale NetZero energy house Edmonton z What does this mean to us? www.riverdalenetzero.ca Connected to EPCOR D&T z How do we use the regulations? z Who can use the regulations? z Are the regulations as easy as they sound? z Will they allow us to generate all our own electricity? z What price will we get paid for our electricity? z Can we make money at it? 8.4 kW solar PV system Laebon Homes net zero energy house z What will our electricity bill look like? Red Deer www.laebon.com Connected to Red Deer Electric Light and Power z What do you do if your electricity delivery company says “no”? 8.4 kW solar PV system Avalon Central Alberta net zero energy house Red Deer Solar Energywww.avaloncentralalberta.com Development Specialists 2 Connected to Red Deer Electric Light and Power Intro: The Prime Focus of this Presentation Prime Focus Not Covered z House-sized micropower systems z Business-sized micropower systems z Inverter-based micropower systems z Synchronous or induction generators using solar or microwind z Systems grid-connected to EPCOR z Systems grid-connected to other and FortisAlberta in the Edmonton electricity deliver companies not in the area Edmonton area z Regulatory paperwork process for z How micropower systems work, getting your micropower system how to design or size them, approved how to find suppliers, what are the costs and economics (these subjects are covered in other presentations) You must skate to where the puck is going 3 …not to where it is now.Solar Energy Development Specialists Wayne Gretzky Three points to take away… 1.
    [Show full text]
  • Electrical – Wiring Methods, Components and Equipment for General Use
    Electrical – Wiring Methods, Components and Equipment for General Use Approved for Public Release; Further Dissemination Unlimited At the completion of this unit you shall be able to: 1. Utilize section Z of the Safety and Health Hazard Inspection Program Checklist to identify compliant and non-compliant safety behaviors. 2. Identify areas of concern requiring immediate action to mitigate or prevent a possible injury. Please use “Slide Show” to properly view this presentation! • Let’s start with a discussion of Electrical Safety. Whenever you work with electrical devices there is a risk of electrical hazards, especially electrical shock. Risks are increased at maintenance and construction sites because many jobs involve electric power tools. Coming in contact with an electrical voltage can cause current to flow through the body, resulting in electrical shock and burns. Serious injury or even death may occur. Electricity has long been recognized as a serious workplace hazard, exposing employees to electric shock, electrocution, burns, fires, and explosions. In 1999, for example, 278 workers died from electrocutions at work, accounting for almost 5 percent of all on-the-job fatalities that year, according to the Bureau of Labor Statistics. What makes these statistics more tragic is that most of these fatalities could have been easily avoided. • When an electrical shock enters the body it may produce different types of injuries. Electrocution results in internal and external injury to body parts or the entire body – often resulting in death. After receiving a “jolt” of electricity all or part of the body may be temporarily paralyzed and this may cause loss of grip or stability.
    [Show full text]
  • EWIS Practices Job Aid 2.0
    Aircraft EWIS Practices Job Aid 2.0 Federal Aviation Administration Aircraft Electrical Wiring Interconnect System (EWIS) Best Practices Job Aid Revision: 2.0 This job aid covers applicable 14 CFR part 25 aircraft (although it is also widely acceptable for use with other types of aircraft such as military, small airplanes, and rotorcraft). This job aid addresses policy; industry EWIS practices; primary factors associated with EWIS degradation; information on TC/STC data package requirements; EWIS selection and protection; routing, splicing and termination practices; and EWIS maintenance concepts (including how to perform a EWIS general visual inspection). The job aid also includes numerous actual aircraft EWIS photos and examples. UNCONTROLLED COPY WHEN DOWNLOADED 1 Aircraft EWIS Practices Job Aid 2.0 Additional Notes • This presentation contains additional speaker notes for most slides • It’s advisable to read these notes while viewing the slide presentation Aircraft EWIS Best Practices Job Aid 2.0 Federal Aviation 2 Administration UNCONTROLLED COPY WHEN DOWNLOADED 2 Aircraft EWIS Practices Job Aid 2.0 Printing the Additional Notes To print the slides and accompanying speaker notes: – Navigate back to the FAA Aircraft Certification job aids web page – Open and print Printable Slides and Notes Aircraft EWIS Best Practices Job Aid 2.0 Federal Aviation 3 Administration UNCONTROLLED COPY WHEN DOWNLOADED 3 Aircraft EWIS Practices Job Aid 2.0 Background • Why the need for EWIS best practices Job Aid? – Accident/Incident Service History – Aging Transport Systems Rulemaking Advisory Committee (ATSRAC) – Enhanced Airworthiness Program for Airplane System (EAPAS) – EAPAS Rule Making Aircraft EWIS Best Practices Job Aid 2.0 Federal Aviation 4 Administration Historically, wiring and associated components were installed without much thought given to the aging aspects: • Fit and forget.
    [Show full text]
  • ELCB Testers
    Technical Catalogue 1904 Test & Measurement Hoyt ELCB Testers General ELCB Testers TEL1 ................................................................................................... 2 Analogue ELCB Testers 810 EL ................................................................................................ 3 1810 EL .............................................................................................. 4 Digital ELCB Testers 1112 EL .............................................................................................. 5 1113 EL .............................................................................................. 6 1612 EL .............................................................................................. 7 8012 EL .............................................................................................. 8 1811 EL .............................................................................................. 9 1812 EL .............................................................................................. 10 1813 EL .............................................................................................. 11 2712 EL .............................................................................................. 12 2820 EL .............................................................................................. 13 4112 EL .............................................................................................. 14 6220 EL .............................................................................................
    [Show full text]
  • Answer the Purpose: 4
    Page 26 1. CONDUCTORS Conductors are defined as materials that easily allow the flow of _________. Metals are _______ conductors while insulators are ______ . The 2 common metals used for conductors in the electrical trade are: ___________ and ______________. Aluminium has become more prevalent for larger C.S.A. conductors as it is cheaper and lighter but more brittle than copper. Current/ Copper/ Aluminium Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. In mainland Europe, a round equivalent is more common. Flat cables (or festoon cables) are made in PVC and Neoprene and are used as trailing cables for cranes, open filed conveyors and shelve service devices. Flat cables offer the advantages of extremely small bending radius’s, high flexibility and minimum wastage of space. Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth.
    [Show full text]
  • Electrical Best Practices Page |1
    Electrical Best Practices Page |1 Contents Scope ........................................................................................................................................................................................................................... 9 Common Electrical Problems ...................................................................................................................................................................................... 10 GENERAL INFORMATION ........................................................................................................................................................................................ 10 FAILURE MODES ..................................................................................................................................................................................................... 10 Short Circuit ........................................................................................................................................................................................................ 10 Open Circuit........................................................................................................................................................................................................ 10 Intermittent Circuit ............................................................................................................................................................................................. 11 Sources
    [Show full text]
  • Electrical Idaho Statutes and Administrative Rules
    2020 Electrical Electrical Idaho Statutes and Administrative Rules Table of Contents Idaho Statutes TITLE 54. PROFESSIONS, VOCATIONS, AND BUSINESSES CHAPTER 10. ELECTRICAL CONTRACTORS AND JOURNEYMAN Declaration of policy Idaho Code § 54-1001 Inspection provisions inapplicable when installation covered by municipal Idaho Code § 54-1001B ordinance Inspections within municipalities -- When authorized Idaho Code § 54-1001C Inspections of modular buildings -- When authorized -- Approval and certi- Idaho Code § 54-1001D fication License essential to engage in business -- Licensure authority exclusive to Idaho Code § 54-1002 the state Administrator authority Idaho Code § 54-1003 Definitions Idaho Code § 54-1003A Inspection of electrical installations -- Notice of corrections -- Disconnect- Idaho Code § 54-1004 ing electrical service Rules -- Inspections -- Inspection permits and fees Idaho Code § 54-1005 Idaho electrical board Idaho Code § 54-1006 Issuance of licenses -- Reciprocity Idaho Code § 54-1007 Duration of license Idaho Code § 54-1008 Revocations or suspension of licenses -- Hearings -- taking testimony Idaho Code § 54-1009 Installations by electrical contractor performed by licensed journeyman -- Idaho Code § 54-1010 Prior certificate holders entitled to license -- List of electricians in contrac- tor’s employ Renewal of licenses or Registrations – inactive licenses Idaho Code § 54-1013 Fees Idaho Code § 54-1014 “Electrical Board Fund” established Idaho Code § 54-1015 Exemptions Idaho Code § 54-1016 Violations of act a misdemeanor
    [Show full text]
  • Energy Harvesting from Body Motion Using Rotational Micro-Generation", Dissertation, Michigan Technological University, 2010
    Michigan Technological University Digital Commons @ Michigan Tech Dissertations, Master's Theses and Master's Dissertations, Master's Theses and Master's Reports - Open Reports 2010 Energy harvesting from body motion using rotational micro- generation Edwar. Romero-Ramirez Michigan Technological University Follow this and additional works at: https://digitalcommons.mtu.edu/etds Part of the Mechanical Engineering Commons Copyright 2010 Edwar. Romero-Ramirez Recommended Citation Romero-Ramirez, Edwar., "Energy harvesting from body motion using rotational micro-generation", Dissertation, Michigan Technological University, 2010. https://doi.org/10.37099/mtu.dc.etds/404 Follow this and additional works at: https://digitalcommons.mtu.edu/etds Part of the Mechanical Engineering Commons ENERGY HARVESTING FROM BODY MOTION USING ROTATIONAL MICRO-GENERATION By EDWAR ROMERO-RAMIREZ A DISSERTATION Submitted in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY (Mechanical Engineering-Engineering Mechanics) MICHIGAN TECHNOLOGICAL UNIVERSITY 2010 Copyright © Edwar Romero-Ramirez 2010 This dissertation, "Energy Harvesting from Body Motion using Rotational Micro- Generation" is hereby approved in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY in the field of Mechanical Engineering-Engineering Mechanics. DEPARTMENT Mechanical Engineering-Engineering Mechanics Signatures: Dissertation Advisor Dr. Robert O. Warrington Co-Advisor Dr. Michael R. Neuman Department Chair Dr. William W. Predebon Date Abstract Autonomous system applications are typically limited by the power supply opera- tional lifetime when battery replacement is difficult or costly. A trade-off between battery size and battery life is usually calculated to determine the device capability and lifespan. As a result, energy harvesting research has gained importance as soci- ety searches for alternative energy sources for power generation.
    [Show full text]
  • Alberta Utilities Commission Micro-Generation Application
    www.auc.ab.ca MICRO-GENERATION NOTICE SUBMISSION GUIDELINE (Version 2.0) September 20, 2017 Table of Contents 1. Introduction ........................................................................................................................................ 2 2. Purpose ......................................................................................................................................... 2 3. Differences between micro-generation and distributed generation ................................................... 2 4. Legal and related matters .................................................................................................................. 3 5. Disclaimer ......................................................................................................................................... 4 6. Micro-generation generating units – types and size .......................................................................... 4 7. Principal stakeholders........................................................................................................................ 5 8. Micro-generation application process summary ................................................................................ 5 9. Guidelines for filing a Micro-Generation Notice form ......................................................................... 7 10. Electricity compensation .................................................................................................................. 11 11. Obligations ......................................................................................................................................
    [Show full text]
  • Operators Manual for KDS Manual Provides Installation, Operation, and Maintenance Instructions
    Operators Manual for KDS Manual provides Installation, Operation, and Maintenance Instructions Model: KDS Kitchen Distribution System Form#: OM015_KDS Date: 11-2016 - Rev1 INTRODUCTION Upon receipt of the Halton KDS (Kitchen Distribution System), inspect the crates immediately for any shipping damage and notify the carrier immediately if damage is found. Halton will not accept responsibility for any shipping damage, but will assist in helping to get a claim filed if needed. The HALTON KITCHEN DISTRIBUTION and SAFETY SYSTEM has been fully assembled and tested at the factory before shipment. When assembled at the installation, according to these instructions, all parts will mate properly and fit according to plan. It should not be necessary for any contractors to make internal modifications. The KDS system is designed for flexibility in satisfying equipment additions and relocations. Once the factory designed KDS is assembled in the field per the original design, movement or additions of Outlets / Gas drops / Water drops / Steam drops etc. is allowed. The “Trade” performing the work shall use UL listed or UR recognized components and will not make additions that will exceed the unit’s UL rating. Note: Refer to the following instructions and drawings for proper installation. HALTON shall not be responsible or liable for improper operation of the KITCHEN DISTRIBUTION and SAFETY SYSTEM due to any design or assembly modifications, or error, of other engineers or contractors. IMPORTANT INFORMATION Read these instructions carefully before commencing installation or maintenance on unit. In order to ensure the performance of the system it is essential that routine maintenance is carried out in accordance with the following instructions.
    [Show full text]
  • Electrical Wiring - OR - WHY DO WE NEED ALL THIS COPPER?!
    Electrical Wiring - OR - WHY DO WE NEED ALL THIS COPPER?! BUREAU OF TRAFFIC OPERATIONS Signals, Lighting & ITS Systems Installation and Inspection Training Objectives • Identify Types of Wires – Size – Insulation • Installation Methods – Pulling – Blowing • Grounding and Bonding – How, where and why – Testing • Splicing conductors – Where are splices permitted? – Splice “kits” – Testing • Terminations – Proper cable/wire termination methods • Electrical Services – Installation and Service Connection • Documentation – Asbuilts – LABEL!! BUREAU OF TRAFFIC OPERATIONS Signals, Lighting & ITS Systems Installation and Inspection Training Wire Size Wire size is measured in AWG (American Wire Gauge) • The AWG number identifies the size of the conductors the smaller the number the larger the diameter (AWG 0000 – 0.46 in , AWG 18 – 0.04 in) • NEC defines process for calculating wire size based on Current, Voltage and length of wire. • Changes in routing may require a change in the wire used to cabinets or field elements. • Most household wiring is usually 12 or 14 AWG • DOT Signal, Lighting and ITS wires range from 18 AWG for communications interconnect to 00+ for power service. • AWG # wire can be either solid or stranded . BUREAU OF TRAFFIC OPERATIONS Signals, Lighting & ITS Systems Installation and Inspection Training Determining Conductor Size • Typically ampacity and sizing is determined by the designer and provided on the plans • De-rating of conductors may need to be determined if the cable routing is revised by field personnel or final job layout – Derating process is documented in the NEC. Generally requires a review of installation conditions and cable rating. BUREAU OF TRAFFIC OPERATIONS Signals, Lighting & ITS Systems Installation and Inspection Training Conductor Insulation and jacket Types Insulation and Jacketing identified in Standard Specifications .
    [Show full text]