Surge Protection, Power Distribution and Uninterruptible Power SECTION R Surge Protection, Power Distribution and Uninterruptible Power Supply Devices INDEX Industrial Surge Protective Devices Overview . .R2 Four-Outlet Plug-Ins . .R3 5100 Series . .R3 Surge Strips . .R4 Surge Protection Modules . .R5 Surge Protection Panels . .R6, R7 74000 Series . .R6 Surge Protection Devices 57000 Series . .R7 52000 Series . .R8 47000 and 52000-7M3 Series . .R9 42000 and 32000 Series . .R10 Low Voltage Communications SPD’s 3400 and 3800 Series . .R11 Surge Counter: 51000 SMC . .R11 Equipment Cabinet SPD’s . .R12 3800 Series . .R12 Surge Protection Receptacles . .R13 Decora Series Four-In-One Series . .R14 Commercial Surge Protection Devices S1000 and S2000 Series Surge Strips . .R15 4950 Series Surge Strips . .R15 5500 and 5505 Series PDU’s with Surge Protection . .R16 Rack-mounted Power Distribution Devices 4505 Series 19" Rack Mount PDUs . .R17 P1000 Series PDUs . .R17 Metered Series PDUs . .R18 Switched Series PDUs . .R19 Residential Surge Protection Devices Meter Socket Surge Adapter . .R20 Secondary Surge Arrestors . .R20 General Purpose Plug-Ins . .R21 51000 Series Surge Protection Panels . .R21 3950 Series Module Bracket . .R22 5950 Series Surge Modules . .R22 Uninterruptible Power Supplies Sine and Online Series UPS Systems . .R23 Pro, Slim and Strip Series UPS Systems . .R23, R24 SURGE PROTECTION DEVICE FEATURES Industrial Grade Surge Protection Devices LEVITON’S SURGE PROTECTIVE DEVICES (SPD’S) ARE DESIGNED TO REDUCE THE RANDOM ENERGY SURGES OF VOLTAGE TRANSIENTS AND ELECTRICAL NOISE ON THE POWER SUPPLY LINE. Volatile transients and noise are present in utility power lines, data networks, telephone lines, closed circuit and cable tv feeds, and any other power or control lines connected to electronic equipment. Leviton’s Surge Protection Devices can be used individually or as part of a coordinated application strategy, called Network Protection, to protect sensitive electronic equipment, in industrial, commercial and residential locations, from the stress and degradation inflicted by voltage transients. Leviton Surge Protection Devices are listed to UL 1449 Second Edition Standards. Leviton’s outstanding Surge Protection Devices divert dam- Features and Benefits aging voltage transients, or surges, away from electronic I Provides seven-mode protection equipment. Transients are diverted away from sensitive I User-replaceable modules microcircuitry, providing protection against catastrophic I failure, costly downtime and data disruptions. Real-time diagnostics monitor power and suppression status for each mode I Diagnostic display panel of 74000/75000 units indicates “Fault”, “Alert” and “Protection” status I Provides surge magnitude, time and date of each surge event I Surge event history downloadable via RS-232 connection 74120-7M3 Surge Protection Devices Panel Mounted Receptacles Stand-Alone Low-Voltage SPD Plug Strips Provides complete protection on all 15-20 Amp single, duplex and four- Provides surge protection for low- Available in a variety of grades, phases even if one module fails; in-one versions with 3-level MOV voltage data and communications its real time diagnostics monitor modular design allows easy replace- phase to neutral, phase to ground lines. power and suppression status. ment of modules. NC, NO contacts and neutral to ground protection. 5350-PT8 shown 5300-PS shown for remote status indication. 8280-IGB shown 57120-M3 shown PDUs UPSs Communication Modules Multi-Phase Panel Protector Mounts on 19" equipment rack; New product line offers the latest Provide surge protection for DC- Provides multiple-phase surge available with or without rocker-style technology and features available powered low-voltage data network protection; 3-phase units are suit- ON/OFF switch; Resettable circuit in Uninterruptible Power Supply products. able for WYE and Delta AC sys- breaker protects against overloading devices. 3803-485 shown tems. NC, NO contacts for remote and power supply failure. U1000-AKP shown status indication. 5500-190 shown 42120-D43 shown R 2 To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com WALL MOUNTED SURGE PROTECTION Industrial Grade Surge Protection Devices Four-Outlet Plug-In Surge Protection Devices — 15 AMP 120V 50, 60 Hz AC 5100 Series UR DESCRIPTION CAT. NO. COLOR APPLICATION 15A Four-Outlet Heavy-Duty DPI 5100-P Beige PC’s and peripherals, electronic cash registers, digital sound systems, video equipment and microwave ovens Clamping Performance SPECIFICATION 5100 5.85 (148.5) Max. single-pulse transient current 26kA (8x20µs, Amps peak) Rated single-pulse transient energy 320 Joules (10x1000µs, Joules) EMI/RFI noise rejection @ 50 Ohms 10-20dB 5kHz-100MHz Cat. A ringwave (6kV, 200A,100kHz) 370V 1.50 3.50 (88.9) Cat. B ringwave (6kV, 500A,100kHz) 420V (38.1) Cat B impulse (6kV, 3kA, 8x20µs) 490 5100-P UL 1449 ratings (8x20µs @ 500A) 330/500/400V (L-N/L-G, N-G) Maximum continuous operating voltage 135V Surge Protection Devices SPECIFICATIONS AND FEATURES TESTING AND CODE COMPLIANCE • Connect directly to standard NEMA 5-15 wall • UL 1449 Listed (File #E-146315) receptacles • Meets ANSI/IEEE C62.41 standards for both • Diagnostic LED’s indicate power & protection status Categories A & B • Three mode protection for Normal & Common • CSA Certified (File #LR-94773) protection: L-N,L-G, N-G • Lifetime Limited Downline Warranty for device & • On-board thermal fusing & overcurrent protection equipment plugged into it via resettable 15A breaker • Filtration reduces high frequency noise MATERIAL CHARACTERISTICS • Maximum continuous operating voltage Operating Temperature: -10°C to 60°C 5100 Series Storage Temperature: -35°C to 60°C • Non-inductive design for compatibility with UPS & SPS or transformer systems • Multi-component suppression circuitry R For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 3 SURGE PROTECTION PLUG STRIPS Industrial Grade Surge Protection Devices Plug Strips UR DESCRIPTION CAT. NO. RATING APPLICATION 6-Outlet Plug Strip w/ON/OFF Switch 5300-PS 15A-120V AC Data-sensitive operations 6-Outlet Plug Strip w/ON/OFF Switch 5300-S15 15A-120V AC Data-sensitive operations w/15 ft. Power Cord 6-Outlet Plug Strip w/ON/OFF Switch 5300-PST 15A-120V AC Telephone line/modem line protection 6-Outlet Plug Strip w/ON/OFF Switch 5300-PSC 15A-120V AC CATV line surge protection 6-Outlet Plug Strip 5300-HTS 15A-120V AC Continues to supply power to load if Hospital Grade Components protection is lost 6-Outlet Plug Strip w/ON/OFF Switch 5300-IPS 15A-120V AC Rugged metal housing for use in rough environments Heavy-Duty 6-Outlet Plug Strip 5200-PS 15A-120V AC For microprocessor-based equipment w/ON/OFF Switch Heavy-Duty 6-Outlet Plug Strip 5200-S15 15A-120V AC For microprocessor-based equipment w/ON/OFF Switch, w/15 ft. Power Cord 5300-HTS General-Duty 6-Outlet Plug Strip 5100-PS 15A-120V AC Compatible with Decora Home Control General-Duty 6-Outlet Plug Strip, 5100-S15 15A-120V AC Compatible with UPS and SPS systems w/15 ft. Power Cord General-Duty 6-Outlet Plug Strip 5100-IPS 15A-120V AC Rugged metal housing for use in rough environments General-Duty 6-Outlet Plug Strip 5100-IS2 20A-120V AC Rugged metal housing for use in rough environments Clamping Performance DESCRIPTION 5100-PS 5200-PS 5300-PS GROUP Max. single-pulse transient current 26kA 39kA 52kA (8x20µs, Amps peak) Rated single-pulse transient energy 720 Joules 940 Joules 1480 Joules (10x1000µs, Joules) EMI/RFI noise rejection @ 10-30dB 40-50dB 50-60dB 50 Ohms 5kHz-100MHz Cat. A ringwave (6kV, 200A,100kHz) 370V 230V 190V Cat. B ringwave (6kV, 500A,100kHz) 420V 270V 210V 5300-PSC Cat B impulse (6kV, 3kA, 8x20µs) 490 370 310 UL 1449 ratings (8x20µs @ 3kA) 400/400/400 330/400/330 330/330/330 (L-N/L-G, N-G) 400/400/400 for 5300-HTS only Surge Protection Devices 5100-OPS SPECIFICATIONS AND FEATURES TESTING AND CODE COMPLIANCE MATERIAL CHARACTERISTICS Plug Strips 5300-HPS 5100-PS, 5200-PS, 5300-PS • Available in Industrial Specification Grade, • UL Listed 544 (File #118936) Operating Temperature: 0°C to 40°C Commercial Specification Grade & General Purpose • UL Listed (File Nos. #1449, 1363, 1283) Storage Temperature: -35°C to 60°C Classifications • CSA Certified (File #LR-94773) 5300-HPS • Clamping profile tightly tracks AC sine wave • Meets ANSI/IEEE C62.41 standards for both Operating Temperature: 0°C to 60°C • Real-time diagnostics monitor power & suppression Categories A & B status Storage Temperature: -35°C to 60°C Plug Strips • Six protected outlets 5100-IPS, 5300-IPS, 5100-IS2 • Lifetime Limited Downline Warranty for device & Operating Temperature:-10°C to 60°C • Resettable circuit breaker & internal fusing equipment plugged into it • May be wall-mounted Storage Temperature: -35°C to 60°C • Equipped with a 6-foot, 14-3AWG power cord R 4 To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com WIRED-IN SURGE PROTECTION MODULES Industrial Grade Surge Protection Devices 4.38 (111.3) Wired-In Surge Protection Modules NOM CUUS LISTED 2.71 (68.8) DESCRIPTION CAT. NO. RATING Single-Phase, 3-Wire 51005-WM 5A, 120V AC Single-Phase, 3-Wire 51010-WM 10A, 120V AC Single-Phase, 3-Wire, DIN-Rail Mounting 51005-DIN 5A, 120V AC Single-Phase, 3-Wire, DIN-Rail Mounting 51010-DIN 10A, 120V AC Single-Phase, 3-Wire 51015-WM 15A 120V AC Single-Phase, 3-Wire 51020-WM 20A 120V AC Single-Phase, 3-Wire, w/DIN-rail mounting 51020-DIN 20A 120V AC Single-Phase, 3-wire (For use in parallel connection) 51020-WMT 20A 120V AC 7.50 (190.5) Single-Phase, 4-Wire 51240-WM 20A 240V AC Single-Phase, w/DIN-rail mounting 51240-DIN 20A 240V AC Performance Specifications SPECIFICATION 51005-WM, 51015-WM, 51240-WM, 51010-WM, 51020-WM, 51240-DIN 51005-DIN, 51015-DIN, 1.85 51010-DIN 51020-DIN, 51020-DIN (47.0) 51020-WMT Max.
Recommended publications
  • Power Distribution and Grounding of Audio, Video And
    Integrating Electronic Equipment and Power into Rack Enclosures Optimized Power Distribution and Grounding for Audio, Video and Electronic Systems MAIN PANEL SUB PANEL (optional) Grounding Conductor Grounded Conductor (neutral) Ground Bar Neutral & Ground Bar Neutral (On insulators) Technical (isolated) Grounded Conductor “single-point” ground bar (Neutral & Ground on insulators combined) Enclosure From Technical (isolated) ground wire terminated Transformer in main panel only (no connection to sub panel ground) Building ground wire or conduit Isolated ground outlet conventional outlet Rev. 4b Table of Contents Preface ........................................................................................................................... 1 Neutral-Ground reversals .............................................................................................. 30 A Note about Signal Paths .............................................................................................. 2 Steps to Troubleshoot Bootleg Grounds and Neutral-Ground Reversals ....................... 32 Ground Loops and Signal Interconnections .................................................................... 2 Auxiliary Ground Rods ................................................................................................... 34 Signal Wiring: Unbalanced & Balanced Interfaces .......................................................... 3 Intersystem Bonding (Cable TV, Satellite TV, Telephone) ............................................. 35 AC Magnetic Fields
    [Show full text]
  • Hospital Isolated Power Systems
    Hospital Isolated Power Systems Class 4800 Catalog 4800CT9801R4/08 08 CONTENTS Description . .Page General Information . 3 Surgical Facility Panels . 29 Isolation Panel Components . 30 Operating Room Panels. 32 ICU/CCU Panels . 35 Dual Output Voltage Isolation Panels . 37 Duplex Isolation Panels . 41 Three-Phase Isolation Panels . 44 Controlled Power Panels . 48 Remote Alarm Indicators . 54 Power/Ground Modules . 56 Remote Annunciator Panels . 60 Iso-Gard® Line Isolation Monitor (LIM) . 62 Digital Clocks, Timers, and Accessories . 63 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Hospital Isolated Power Systems Overview and History Overview This catalog has three purposes: • To demonstrate to hospitals the need for isolated systems • To guide the engineer in the application of hospital ungrounded systems • To describe in detail the Square D® brand equipment used to design effective and economical isolated ungrounded systems Schneider Electric has been building isolating transformers for hospital use since the first equipment standards appeared in 1944. We have built an enviable reputation for reliability, low sound levels, and minimum inherent leakage. Proof of the engineered superiority of Square D brand products is found throughout the country in numerous installations, many dating to the earliest applications of isolating transformers. This bulletin is not intended as a “do it yourself” manual for installation of hospital isolated systems.
    [Show full text]
  • Cord & Cordset Products
    Cord & Cordset Products FOR INDUSTRIAL, COMMERCIAL AND SPECIALTY APPLICATIONS CORD & CORDSET& CORD PRODUCTS NOVEMBER 2017 Cord & Cordset This catalog contains in-depth What’s New? information on the most OUR BEST CORD JUST GOT BETTER comprehensive line of cord and The rubber cord that changed an industry just got better. General cordset products. General Cable’s Cable now offers Super Vu-Tron® Supreme with GenClean® flexible cord products are available technology as a standard feature, enabling users to benefit from this proprietary cleanable jacket technology. An outstanding today for commercial, industrial solution for the food and beverage industry, Super Vu-Tron Supreme with GenClean offers all the benefits and durability and specialty applications. Our of rubber cord with a cleanable jacket that permits unwanted contractor-grade extension cords, material to be more readily removed in a wash cycle. Learn more about GenClean on page 9. specialty cords, utility lights and accessories provide power for tools THE POWER IS ON — FROGHIDE® ULTRA FLEX® and equipment, and temporary LIGHTED EXTENSION CORD lighting on residential, commercial and industrial job sites. With the help of contractors, tradesmen and homeowners, we’ve created the ultimate extension cord. More flexible, more durable and more identifiable than any other cord on the market, featuring The product and technical sections a lighted connector to indicate the power is on — the one and only have been developed with an easy- FrogHide Ultra Flex lighted extension cord. Carol® Brand FrogHide Ultra Flex lighted extension cords are bonded to the caps and to-use “spec-on-a-page” format. connectors with heavy-duty strain reliefs built in for lasting They feature the latest information strength, even in rough applications.
    [Show full text]
  • Plug Patterns… and Counting
    INTER ISSUE 1 | SUMMER 2011 MAGAZINE FALL 2011 | ISSUE 1 Plug Patterns… and Counting PLUS: • Partially Insulated Swiss Plugs Increase Safety pg 6 • Saudi Arabian Standards Changed And Enforced pg 18 • A Closer look at the Brazilian Plug Standard pg 20 No minimum order requirements for Continental European cords Interpower Corporation manufactures Continental European power cords and cord sets. The Continental European plug carries all the appropriate approvals. Many lengths are in stock, and we offer a 1-week manufacturing lead time for nonstock cords. Customize your power cord or cord set! Choose from a variety of colors with no set-up charge. Interpower Corporation can also mold IEC 60320 C13 and C19 connectors. We offer straight and four angled IEC 60320 C13 connectors. All connectors fi t our existing connector locks. Connector locks secure the connector, preventing accidental removal or interruption. Custom lengths, labeling and packaging are also available upon request. Our Customer Service Department is ready to serve you from 7 a.m. to 7 p.m. Central Standard Time with no automated call attendant; receptionists answer every phone call. From 1 piece to 1,000 pieces or more we offer no minimum order requirements, so you only purchase what you need. With a 1-week manufacturing lead time, and no minimum order requirements, Interpower Corporation is your one-stop shop for power system components. • Continental European plug carries all appropriate approvals • 1-week manufacturing lead time on any nonstock Continental European power cord or cord set Toll-Free Phone: (800) 662-2290 • No minimum order requirements Order a free Catalog on CD today! E-mail [email protected] or call toll-free.