Dynamo® Aboveground Pool Pump

Total Page:16

File Type:pdf, Size:1020Kb

Dynamo® Aboveground Pool Pump DYNAMO® ABOVEGROUND POOL PUMP ENGINEERED POMPE EN BOMBA PLASTIC PUMP PLASTIQUE PLASTICA DE INDUSTRIEL DISEÑO INSTALLATION, MANUEL MANUAL DE OPERATION & D’INSTALLATION, INSTALACION, SERVICE D’UTILISATION & OPERACION Y MANUAL D’ENTRETIEN SERVICIO PUMP IS DESIGNED AND LA POMPE EST CONCUE ET LA BOMBA HA SIDO DISEÑADA INTENDED FOR USE TO PREVUE POUR FAIRE Y TIENE COMO FIN SER USADA CIRCULATE WATER IN CIRCULER L’EAU DES PARA HACER CIRCULAR AGUA SWIMMING POOLS AND SPA PISCINES ET BAINS EN PISCINAS Y SPAS TOURBILLONS WARNING AVERTISSEMENT ADVERTENCIA THIS MANUAL CONTAINS LE PRESENT MANUEL CONTIENT ESTE MANUAL CONTIENE IMPORTANT SAFETY INFORMATION DES INFORMATIONS TRES INFORMACION DE IMPORTANCIA WHICH MUST BE FURNISHED IMPORTANTES CONCERNANT LA CRITICA QUE DEBE SER TO THE END USER. FAILURE TO SECURITE, QUI DOIVENT ETRE ENTREGADA AL USUARIO FINAL. READ AND FOLLOW INSTRUCTIONS COMMUNIQUEES A L’UTILISATEUR. SI NO SE LEEN NI SE SIGUEN ESTAS COULD RESULT IN SERIOUS LE FAIT DE NE PAS LIRE NI SUIVRE INSTRUCCIONES SE PUEDEN PERSONAL INJURY AND/OR LES INSTRUCTIONS PEUT AVOIR PRODUCIR LESIONES PERSONALES MAJOR PROPERTY DAMAGE. POUR RESULTATS DE BLESSURES GRAVES Y/O DAÑO A LA PROPIEDAD GRAVES ET/OU DES DEGATS DE IMPORTANCIA. MATERIELS TRES IMPORTANTS. Sanford, NC (USA) Sanford, NC (USA) Sanford, NC (USA) (919) 566-8000 (919) 566-8000 (919) 566-8000 Moorpark, CA (USA) Moorpark, CA (USA) Moorpark, CA (USA) (805) 553-5000 (805) 553-5000 (805) 553-5000 IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS General Warnings • Never open the inside of the drive motor enclosure. There is a IMPORTANT NOTICE capacitor bank that holds a 230 VAC charge even when there is no This guide provides installation and operation instructions for this pump. power to the unit. Consult Pentair with any questions regarding this equipment. • The pump is not submersible. Attention Installer: This guide contains important information about the • The pump is capable of high flow rates; use caution when installing installation, operation and safe use of this product. This information should and programming to limit pumps performance potential with old or be given to the owner and/or operator of this equipment after installation questionable equipment. or left on or near the pump. • Code requirements for electrical connection differ from country to Attention User: This manual contains important information that will help country, state to state, as well as local municipalities. Install equipment you in operating and maintaining this product. Please retain it for future in accordance with the National Electrical Code and all applicable reference. local codes and ordinances. • Before servicing the pump; switch OFF power to the pump by READ AND FOLLOW ALL INSTRUCTIONS disconnecting the main circuit to the pump. SAVE THESE INSTRUCTIONS • This appliance is not intended for use by persons (including children) of reduced physical, sensory or mental capabilities, or lack of experience This is the safety alert symbol. When you see this and knowledge, unless they have been given supervision or instruction symbol on your system or in this manual, look for concerning the use of the appliance by a person responsible for their one of the following signal words and be alert to safety. the potential for personal injury. Warns about hazards that can cause death, FAILURE TO FOLLOW ALL INSTRUCTIONS AND serious personal injury, or major property damage WARNINGS CAN RESULT IN SERIOUS BODILY if ignored. INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. Warns about hazards that may cause death, INSTALLERS, POOL OPERATORS AND OWNERS MUST READ serious personal injury, or major property damage THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S if ignored. MANUAL BEFORE USING THIS PUMP. THESE WARNINGS AND Warns about hazards that may or can cause minor THE OWNER’S MANUAL MUST BE LEFT WITH THE POOL OWNER. personal injury or property damage SUCTION ENTRAPMENT HAZARD: STAY OFF if ignored. THE MAIN DRAIN AND AWAY FROM ALL SUCTION NOTE Indicates special instructions not related to OUTLETS! hazards. Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing F or damaged. THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES When installing and using this electrical equipment, basic safety A STRONG VACUUM AT THE MAIN DRAIN AT THE BOTTOM OF THE precautions should always be followed, include the following: BODY OF WATER. THIS SUCTION IS SO STRONG THAT IT CAN TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE Do not permit children to use this product. PROXIMITY TO A DRAIN OR A LOOSE OR BROKEN DRAIN COVER RISK OF ELECTRICAL SHOCK. Connect only to OR GRATE. a branch circuit protected by a ground-fault circuit- THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF interrupter (GFCI). Contact a qualified electrician if you cannot verify that THE POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR the circuit is protected by a GFCI. BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAPMENT, EVISCERATION AND/OR This unit must be connected only to a supply circuit DEATH. that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should The suction at a drain or outlet can cause: be tested on a routine basis. To test the GFCI, push the test button. Limb Entrapment: When a limb is sucked or inserted into an opening The GFCI should interrupt power. Push the reset button. Power should resulting in a mechanical bind or swelling. This hazard is present when be restored. If the GFCI fails to operate in this manner, the GFCI is a drain cover is missing, broken, loose, cracked or not properly secured. defective. If the GFCI interrupts power to the pump without the test button Hair Entanglement: When the hair tangles or knots in the drain cover, being pushed, a ground current is flowing, indicating the possibility of an trapping the swimmer underwater. This hazard is present when the flow electric shock. Do not use this pump. Disconnect the pump and have the rating of the cover is too small for the pump or pumps. problem corrected by a qualified service representative before using. Body Entrapment: When a portion of the body is held against the drain This pump is for use with permanent swimming cover trapping the swimmer underwater. This hazard is present when the pools and may also be used with hot tubs and spas drain cover is missing, broken or the cover flow rating is not high enough if so marked. Do not use with storable pools. A permanently-installed pool for the pump or pumps. is constructed in or on the ground or in a building such that it cannot be Evisceration/Disembowelment: When a person sits on an open pool readily disassembled for storage. A storable pool is constructed so that (particularly a child wading pool) or spa outlet and suction is applied directly it is capable of being readily disassembled for storage and reassembled to the intestines, causing severe intestinal damage. This hazard is present to its original integrity. when the drain cover is missing, loose, cracked, or not properly secured. IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, HAZARDOUS PRESSURE: STAND CLEAR OF toe or knuckle is caught in an opening of an outlet or drain cover. This PUMP AND FILTER DURING START UP hazard is present when the drain cover is missing, broken, loose, cracked, Circulation systems operate under high pressure. or not properly secured. When any part of the circulating system (i.e. NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN locking ring, pump, filter, valves, etc.) is serviced, ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL CODES, air can enter the system and become pressurized. STANDARDS AND GUIDELINES. Pressurized air can cause the pump housing cover, filter lid, and valves TO MINIMIZE THE RISK OF INJURY DUE TO to violently separate which can result in severe personal injury or death. SUCTION ENTRAPMENT HAZARD: Filter tank lid and strainer cover must be properly secured to prevent • A properly installed and secured ANSI/ASME A112.19.8 approved violent separation. Stand clear of all circulation system equipment when anti-entrapment suction cover must be used for each drain. turning on or starting up pump. • Each suction cover must be installed at least three (3’) feet apart, as Before servicing equipment, make note of the filter pressure. Be sure measured from the nearest point to nearest point. that all controls are set to ensure the system cannot inadvertently start • Regularly inspect all covers for cracks, damage and advanced during service. Turn off all power to the pump. IMPORTANT: Place filter weathering. manual air relief valve in the open position and wait for all pressure • If a cover becomes loose, cracked, damaged, broken or is missing, in the system to be relieved. replace with an appropriate certified cover. Before starting the system, fully open the manual air relief valve and place • Replace drain covers as necessary. Drain covers deteriorate over all system valves in the “open” position to allow water to flow freely from the time due to exposure to sunlight and weather. tank and back to the tank. Stand clear of all equipment and start the pump. • Avoid getting hair, limbs or body in close proximity to any suction cover, pool drain or outlet. IMPORTANT: Do not close filter manual air relief valve until all • Disable suction outlets or reconfigure into return inlets. pressure has been discharged from the valve and a steady stream A clearly labeled emergency shut-off switch for the of water appears.
Recommended publications
  • Based on Bicycle Dynamic Energy
    © 2021 JETIR July 2021, Volume 8, Issue 7 www.jetir.org (ISSN-2349-5162) Developing A Vehicle - Based On Bicycle Dynamic Energy 1V Dhanush Kumar, 1Pavan Yadhav, 1Naveen Reddy A, 1P M Nitesh Kumar, 2Anand Babu K 1U G Scholar, 2Assistant Professor 1,2School of Mechanical Engineering, REVA University, Bengaluru-560064, Karnataka, India. Abstract:- There are so many vehicles that came to influence in the existing world. Their operating systems are based on usual fossil fuels system. At the present sense the fossil fuel can exceed only for a certain period after that we have to go for a change to other methods. Thus we have made an attempt to design and fabricate an ultimate system (solar cycle) which would produce cheaper and effective result than the existing system. This will be very useful needs of the world. An attempt is made in the fabrication of solar powered system for a two-wheeler. The drive system of the normal cycle is not altered. This system is two in one system. The cycle is operated either by pedaling manually battery and motor driving mechanism. Index Term: Dynamo, Throttle, Pedaling, Battery, Sprocket I. Introduction:- All vehicles that are in the market cause pollution and the fuel cost is also increasing day by day. In order to compensate the fluctuating fuel cost and reducing the pollution a good remedy is needed i.e. our transporting system. Due to ignition of hydrocarbon fuels, in the vehicle, sometime difficulties such as wear and tear may be high and more attention is needed for proper maintenance.
    [Show full text]
  • July 5, 1938. A. CALLSEN 2,123,133 APPARATUS for SWITCHING on the STARTER of an INTERNAL COMBUSTION ENGINE Filed Jan
    July 5, 1938. A. CALLSEN 2,123,133 APPARATUS FOR SWITCHING ON THE STARTER OF AN INTERNAL COMBUSTION ENGINE Filed Jan. 25, 1937 2. Sheets-Sheet l July 5, 1938. A. CALS EN 2,123,133 APPARATUS FOR SWITCHING ON THE STARTER OF AN INTERNAL COMBUSTION ENGINE Filed Jan. 25, 1937 2. Sheets-Sheet 2 Patented July 5, 1938 2,123,133 UNITED STATES PATENT OFFICE 2,123,133 APPARATUS FOR SWITCHING ON THE STARTER OF AN INTERNAL COMBUSTION ENGINE Albert Casen, stuttgart-Botnang, Germany, as signor to Robert Bosch Gesellschaft mit be schrankter Haftung, a corporation of Ger many Application January 25, 1937, Serial No. 122,261 In Germany February 1, 1936 15 Claims. (Ch. 290-36) The invention relates to an apparatus for ing the starting exactly as When accelerating. switching on the starter of an internal combus The foot can thus be moved back even into its tion engine for use on vehicles, in which other initial position, and if desired, removed wholly elements of the vehicle control besides the starter from the pedal. 5 are operated by a common operating member. The invention is more particularly described In known apparatus of this kind, the clutch With reference to the accompanying drawings, in pedal or accelerator pedal is connected with the Which:- SWitch of the starter by a clutch which is engaged Figure 1 is a diagrammatic view of One arrange when the engine is stopped, while it is released ment of switch control apparatus. 0 by the vacuum of the engine induction pipe or Figures 2, 3, and 4 are similar views of alter 10 by a relay fed from the lighting dynamo when native constructions.
    [Show full text]
  • Operator's Manual
    OPERATOR'S MANUAL MODELS GR2020G GR2120 GR2120AU G R 2 0 2 0 G · G R 2 1 2 0 · G R 2 1 2 0 1BDAHAOAP0580 A AS . D . 1 - 1 . - . AK Code No. K1270-7122-1 U READ AND SAVE THIS MANUAL PRINTED IN U.S.A. © KUBOTA Corporation 2014 ABBREVIATION LIST Abbreviations Definitions API American Petroleum Institute PTO Power Take Off PT Permanent Type (=Ethylene glycol anti-freeze) rpm Revolutions Per Minute SAE Society of Automotive Engineers KRA Kubota Reverse Awareness System KUBOTA Corporation is ··· Since its inception in 1890, KUBOTA Corporation has grown to rank as one of the major firms in Japan. UNIVERSAL SYMBOLS To achieve this status, the company has through the years diversified the range of its products and services to a remarkable As a guide to the operation of your tractor, various universal symbols have been utilized on the instruments and extent. Nineteen plants and 16,000 employees produce over 1,000 controls. The symbols are shown below with an indication of their meaning. different items, large and small. All these products and all the services which accompany them, Safety Alert Symbol Coolant Temperature however, are unified by one central commitment. KUBOTA makes products which, taken on a national scale, are basic necessities. Gasoline Fuel Mower-Lowered position Products which are indispensable. Products which are intended to help individuals and nations fulfill the potential inherent in their Diesel Fuel Mower-Raised position environment. KUBOTA is the Basic Necessities Giant. Brake Headlight This potential includes water supply, food from the soil and from the sea, industrial development, architecture and construction, Parking Brake Headlight-ON transportation.
    [Show full text]
  • History of Electric Light
    SMITHSONIAN MISCELLANEOUS COLLECTIONS VOLUME 76. NUMBER 2 HISTORY OF ELECTRIC LIGHT BY HENRY SGHROEDER Harrison, New Jersey PER\ ^"^^3^ /ORB (Publication 2717) CITY OF WASHINGTON PUBLISHED BY THE SMITHSONIAN INSTITUTION AUGUST 15, 1923 Zrtie Boxb QSaftitnore (prcee BALTIMORE, MD., U. S. A. CONTENTS PAGE List of Illustrations v Foreword ix Chronology of Electric Light xi Early Records of Electricity and Magnetism i Machines Generating Electricity by Friction 2 The Leyden Jar 3 Electricity Generated by Chemical Means 3 Improvement of Volta's Battery 5 Davy's Discoveries 5 Researches of Oersted, Ampere, Schweigger and Sturgeon 6 Ohm's Law 7 Invention of the Dynamo 7 Daniell's Battery 10 Grove's Battery 11 Grove's Demonstration of Incandescent Lighting 12 Grenet Battery 13 De Moleyns' Incandescent Lamp 13 Early Developments of the Arc Lamp 14 Joule's Law 16 Starr's Incandescent Lamp 17 Other Early Incandescent Lamps 19 Further Arc Lamp Developments 20 Development of the Dynamo, 1840-1860 24 The First Commercial Installation of an Electric Light 25 Further Dynamo Developments 27 Russian Incandescent Lamp Inventors 30 The Jablochkofif " Candle " 31 Commercial Introduction of the Differentially Controlled Arc Lamp ^3 Arc Lighting in the United States 3;^ Other American Arc Light Systems 40 " Sub-Dividing the Electric Light " 42 Edison's Invention of a Practical Incandescent Lamp 43 Edison's Three-Wire System 53 Development of the Alternating Current Constant Potential System 54 Incandescent Lamp Developments, 1884-1894 56 The Edison " Municipal
    [Show full text]
  • Powering the Electric Vehicle with a Dynamo Using Wind Energy
    JOURNAL OF CRITICAL REVIEWS ISSN- 2394-5125 VOL 7, ISSUE 19, 2020 POWERING THE ELECTRIC VEHICLE WITH A DYNAMO USING WIND ENERGY Mr. Kamalpreet Singh1, Dr. Harbinder Singh2, Dr. Harpal Singh3, Dr. Mohit Srivastava4 1Computer Science Engineering, Chandigarh Engineering College, Landran, Mohali, India. 2,3,4Electronics and Communication Engineering Department, Chandigarh Engineering College, Landran, Mohali, India. E-mail: [email protected], [email protected], [email protected], [email protected] Received: 14 March 2020 Revised and Accepted: 8 July 2020 ABSTRACT: The main objective of this paper is to represent a method for powering the electric car with a dynamo using wind energy. We want to solve the major disadvantage faced by an electric vehicle that is the discharge of the battery in case there is no power source. In case there is no power station nearby then electric vehicle can’t reach its desired destination. To solve this problem dynamo can be used. Dynamo is a device that converts mechanical energy into electric energy. Hence by using this property of a dynamo, this problem can be solved. The description of this technique is placing a dynamo behind the radiator and fan in front of the radiator. A hole is created at the centre of the radiator to connect the dynamo with the fan using a shaft. Due to locomotion of a car fan will rotate and current will be produced with the help of a dynamo. This technique has one more benefit that is efficiency of heat dissipation from the radiator will increase with the help of a fan.
    [Show full text]
  • Monitoring Internal Combustion Engines by Neural Network Based Virtual Sensing
    Monitoring Internal Combustion Engines by Neural Network Based Virtual Sensing R.J.Howlett, M.M.de Zoysa, S.D.Walters Transfrontier Centre for Automotive Research (TCAR), Engineering Research Centre, University of Brighton, Brighton, U.K. Email [email protected] Abstract Over the past two decades the manufacturers of internal-combustion engines that are used in motor vehicles have been very successful in reducing the harmful side-effects of their products on the environment. However, they are under ever-increasing pressure to achieve further reductions in the quantities of polluting gases emitted by the engine, and a decrease in the amount of fuel consumed per kilometre. At the same time, vehicle characteristics that are desirable to the driver must not be compromised. Satisfying these diverse requirements requires precise engine control and comprehensive monitoring of the operational parameters of the power unit. Engines are highly price- sensitive, and it is desirable to achieve the increased level of measurement that is required for enhanced control without additional sensory devices. Thus, the indirect estimation of quantities of interest using virtual-sensor techniques, without direct measurement using dedicated sensors, is a research area with considerable potential. Intelligent-systems techniques, such as neural-networks, are attractive for application in this area because of their capabilities in pattern- recognition, signal analysis and interpretation. For this reason, the use of neural-networks in the monitoring and control of motor-vehicle engines is an area of research which is receiving increasing attention from both the academic and commercial research communities. A virtual-sensor technique, the Virtual Lambda Sensor, is described here which uses a neural-network for the estimation of air-fuel ratio in the engine.
    [Show full text]
  • Emerson Replacement Motors
    Emerson Replacement Motors Square Flange Pool And Spa Motors Category “S” SF Catalog Motor Length HP SF RPM Volt Freq Amps Number Frame Less Shaft Wgt Price Standard Efficient- Low Service Factor- Up-Rated- Switchless Design 6.5” Frame Diameter ¾ 1.27 3450 230/115 60 5.4/10.8 EB852 56Y 11.24 22 298.00 1 1.25 3450 230/115 60 7/14 EB853 56Y 11.74 25 340.00 1½ 1.10 3450 230/115 60 7.7/15.4 EB854 56Y 11.74 26 396.00 2 1.10 3450 230/115 60 10.8/21.6 EB859 56Y 12.99 33 508.00 2½ 1.04 3450 230 60 11.5 EB840 56Y 12.74 33 626.00 SF Catalog Motor Motor HP SF RPM Volt Freq Amps Number Frame Length Wgt Price Standard Efficient- Low Service Factor- Up-Rated- Switch Type 5.5” Frame Diameter ½ 1.30 3450 230/115 60 4.1/8.2 EUSQ1052/SQD5UP1 48Y 9.5 19 285.00 ¾ 1.27 3450 230/115 60 5.9/11.8 EUSQ1072/SQD7UP1 48Y 10.28 22 298.00 1 1.25 3450 230/115 60 7.4/14.8 EUSQ1102/SQD10UP1 48Y 10.78 24 340.00 1½ 1.10 3450 230/115 60 8.8/17.6 EUSQ1152/SQD15UP1 48Y 11.78 29 396.00 2 1.10 3450 230/115 60 9.2/18.4 EUSQ1202/SQD20UP1 48Y 12.28 33 508.00 . C-Flange Pool And Spa Motors Category “C” and “J” SF Catalog Motor Length HP SF RPM Volt Freq Amps Number Frame Less Shaft Wgt Price Standard Efficient- Low Service Factor- Up-Rated- Switchless Design 6.5” Frame Diameter ¾ 1.00 3450 230/115 60 4.4/8.8 EB227 56J 10.27 21 290.00 1 1.00 3450 230/115 60 6/12 EB228 56J 10.77 24 324.00 1½ 1.00 3450 230/115 60 7/14 EB229 56J 10.77 25 367.00 2 1.00 3450 230/115 60 9/18 EB230 56J 12.02 31 506.00 2½ 1.00 3450 230 60 10.5 EB231 56J 11.77 33 605.00 Standard Efficient- Low Service Factor- Up-Rated- Switch Type 5.5” Frame Diameter ¾ 1.00 3450 230/115 60 5.9/11.8 EUST1072/JD75UP1 56J 10.44 18 290.00 1 1.00 3450 230/115 60 6.8/13.6 EUST1102/JD10UP1 56J 11.19 19 324.00 1½ 1.00 3450 230/115 60 8.7/17.4 EUST1152/JD15UP1 56J 11.44 24 367.00 2 1.00 3450 230/115 60 9.2/18.4 EUST1202/JD20UP1 56J 11.94 28 506.00 Polaris Pool Sweep Pump- New Style ¾ 1.50 3450 115/230 60 12.8/6.0 EB625 56C 14.00 25 370.00 22-1 Emerson Replacement Motors Continued .
    [Show full text]
  • AVL Consumption Measurement Systems
    AVL Consumption Measurement Systems Integrated Consumption Testing Solutions from Engine Testbed up to On-Road Application and Flow Measurement for Component Testing AVL Consumption Measurement Systems YOUR BENEFITS MARKET REQUIREMENTS AVL APPROACH • Shorter time needed to achieve development targets due to reliable AVL More stringent laws and regulations with regard to The call for higher test bed efficiency does not only More than 50 years of know-how in the field of con- consumption measurement systems, ensuring high levels of engine test bed CO2 and fuel consumption reductions in combination mean an easy installation and quick commission- sumption measurement technology, clever modular availability. with rapidly growing measurement costs are rais- ing procedure for the measurement system; it also product concepts in combination with a global ing the pressure on OEMs to develop engines even means a reliable fuel supply for the engine with pre- presence, sophisticated service and system compe- • Substantially reducing testing effort by means of shorter measurement faster. Development engineers of diesel and gasoline selected parameters, such as fuel temperature and tences make AVL the market leader in the field of times and high levels of measurement accuracy (for example, the reduc- engines are increasingly forced to implement mea- pressure. Highly precise fuel temperature control is consumption measurement. tion of the measurement effort during automatic engine calibration). surements in automatic operation with ever shorter required to achieve high measurement accuracy in measurement times, or in transient modes. the overall system at the engine test bed, even in • Protection of investments through modular design: Easy subsequent ex- case of low fuel consumption values.
    [Show full text]
  • Dynamo Or Magneto-Electric Ma Chine. No
    (Model.) 2. Sheets-Sheet i. C. E. BALL Dynamo or Magneto-Electric Ma Chine. No. 238,631. Patented March 8, 1881. Sir - Z “ZZZZZZZZZZZZZ ZO m/ITNESSES. JNVENTOR, 4 TTORNEY: N, PETERS. PHOTO-THOGRAPHER, was lingtoN. O. C. - - (Model.) 2. Sheets-Sheet 2, C. E. BALL Dynamo or Magneto-Electric Machine. No. 238,631. Patented March 8, 1881. MITWESSES. IWYENTOR, 4/26.4%rver- a 6. 322 1427, 72-7---Y, 4 roRVE3 N.PETER8, Pioto-liographER. WashiGTON, d. c. UNITED STATES PATENT OFFICE. CHARLES E. BALL, OF PHILADELPHIA, PEN NSYLVANIA. DYNAMO OR MAGNETO ELECTRIC MACH NE. SPECIFICATION forming part of Letters Patent No. 238,681, dated March 8, 1881. Application filed November 18, 1880. (Model.) To all chon it may concern: the armatures between the opposite poles of Be it known that I, CHARLES E. BALL, a the same magnet, as is usual, I arrange them citizen of the United States, residing at the to rotate between unlike poles of two or more city of Philadelphia, in the county of Philadel field-magnets, and preferably in opposite di 55 phia and State of Pennsylvania, have invented rections. Each of the field-magnets has its new and useful Improvements in Dynamo or poles opposed to two armatures, while, con Magneto Electric Machines, of which the fol versely, each armature rotates within the in lowing is a specification, reference being had fluence of the opposing poles, respectively, of to the accompanying drawings, wherein two field-magnets, and hence I obtain two O Figure 1 is a plan of a (ly namo or magneto sepalate and (listinct coln stant currents from electric machine, composed of two field-mag as may allnatures.
    [Show full text]
  • Battery Charged Power Cycle
    International Journal of Scientific & Engineering Research Volume 9, Issue 5, May-2018 ISSN 2229-5518 109 BATTERY CHARGED POWER CYCLE Nitin madhavi1, Mayuresh Shirke2,Prayag Kharpade3, Mustaq Shaikh4, Prof. Ashish Bandewar5 1Student, Saraswati college of engineering,India, [email protected] 2Student, Saraswati college of engineering,India, [email protected] 3Student, Saraswati college of engineering,India, [email protected] 4Student, Saraswati college of engineering,India, [email protected] 5Professor, Saraswati college of engineering,India, [email protected] . Abstract: This paper presents the development of an Keywords: BLDC Motor, Dynamo, Throttle, Circuit, associate degree, “Electric Bicycle System” with an Lead-acid Batteries. innovative approach. The aim of this paper is to show that the normal bi-cycle can be upgraded to electric one by some means– that including the development of a regenerative braking system and innovative BLDC motor control – but also uses real- time sensing and the powers of crowd sourcing to improve the cycling experience; get IJSERIntroduction: When thinking of possible senior more people riding bikes; and to aid in the design and projects, we all decided that we wanted to do development of cities. Electric bikes have simultaneously something that would somehow be beneficial to the gained popularity in many regions of the world and some planet. We decided that the electric bicycle would be have suggested that it could provide an even higher level of service compared to existing systems. There are several the best fit. The electric bicycle offers a cleaner challenges that are related electric cycle design: electric- alternative to travel short-to-moderate distances assisted range, recharging protocol and battery checkout rather than driving a gasoline-powered car.
    [Show full text]
  • Download Paper (1.05
    Paper ID #18466 Education through Applied Learning and Hands-on Practical Experience with Flex Fuel Vehicles Dr. Hazem Tawfik, State University of New York, Farmingdale Prof. Tawfik obtained his Ph.D. in Mechanical Engineering, from University of Waterloo, Ontario, Canada. He has held a number of industrial & academic positions and affiliations with organizations that included Brookhaven National Laboratory (BNL), Rensselaer Polytechnic Institute (RPI), Stony Brook University (SBU), Massachusetts Institute of Technology (MIT), Atomic Energy of Canada Inc., Ontario Hydro, NASA Kennedy, NASA Marshall Space Flight Centers, and the U.S. Naval Surface Warfare Cen- ter at Carderock, Md. Dr. Tawfik is the co-author of more than 60 research papers in the areas of Hydrogen Fuel Cells, Biomass Energy, Thermo- fluids and Two Phase Flow published in prestigious peer reviewed journals and conference symposiums. He holds numerous research awards and owns the rights to four patents in the Polymer Electrolyte Membrane (PEM) fuel cells area. Currently, Dr. Tawfik is a SUNY Distinguished Service Professor and the Director of the Institute for Research and Technology Transfer (IRTT) at Farmingdale State College of the State University of New York. Dr. Yeong Ryu, State University of New York, Farmingdale YEONG S. RYU graduated from Columbia University with a Ph.D. and Master of Philosophy in Mechan- ical Engineering in 1994. He has served as an associate professor of Mechanical Engineering Technology at Farmingdale State College (SUNY) since 2006. In addition, he has conducted various research projects at Xerox Corporation (1994-1995), Hyundai Motor Corporation (1995-1997), and New Jersey Institute of Technology (2001-2003).
    [Show full text]
  • Facebook's Data Center-Wide Power Management System
    Dynamo: Facebook’s Data Center-Wide Power Management System Qiang Wu, Qingyuan Deng, Lakshmi Ganesh, Chang-Hong Hsu∗, Yun Jin, Sanjeev Kumary, Bin Li, Justin Meza, and Yee Jiun Song Facebook, Inc. ∗University of Michigan Abstract—Data center power is a scarce resource that to construct a new power delivery infrastructure and every often goes underutilized due to conservative planning. This megawatt of power capacity can cost around 10 to 20 million is because the penalty for overloading the data center power USD [2], [3]. delivery hierarchy and tripping a circuit breaker is very high, potentially causing long service outages. Recently, dynamic Under-utilizing data center power is especially inefficient server power capping, which limits the amount of power because power is frequently the bottleneck resource limiting consumed by a server, has been proposed and studied as a way the number of servers that a data center can house. It is to reduce this penalty, enabling more aggressive utilization of provisioned data center power. However, no real at-scale even more so with the recent trend of increasing server solution for data center-wide power monitoring and control power density [4], [5]. Figure 1 shows that server peak power has been presented in the literature. consumption nearly doubled going from the 2011 server (24- In this paper, we describe Dynamo – a data center-wide core Westmere-based) to the 2015 server (48-core Haswell- power management system that monitors the entire power based) at Facebook. This trend has led to the proliferation of hierarchy and makes coordinated control decisions to safely ghost spaces and efficiently use provisioned data center power.
    [Show full text]