Process Recovery Boilers

Total Page:16

File Type:pdf, Size:1020Kb

Process Recovery Boilers Process Recovery Boilers Reliable and effi cient steam producti on for the pulp and paper industry Since 1929, when The Babcock & Wilcox Company (B&W) developed the world’s fi rst Kraft recovery boiler with G.H. Tomlinson, our recovery boiler design has evolved with many new features and customer benefi ts. Our recovery boilers off er high availability with safe operati on and low maintenance. Proven experience to meet the energy requirements of today’s pulp and paper mills B&W’s recovery boilers pro- vide owners and operators with increased effi ciency, reliability and fl exible operati on that lowers your overall boiler lifecycle cost. B&W PR boiler design benefi ts: • Increased effi ciency The latest process recovery (PR) boiler design from • High availability Babcock & Wilcox (B&W) is the leading-edge technology • Improved safety in the industry. • Low emissions (CO, NOx, SO2 and VOC parti culate) With the largest installed base in the world of more • High solids fi ring for opti mized than 350 recovery boilers, B&W is committed to thermal effi ciency the pulp and paper industry by helping today’s energy- • Advanced steam drum internals and riser/supply systems for circulati on intensive mills become more competi ti ve and profi table. safety margin • Reduced constructi on costs and greater Our recovery boiler customers benefi t from B&W’s schedule certainty with modularized design industry leadership in uti lity boiler design. We can apply • Overall lower boiler lifecycle cost uti lity boiler technology advancements such as high- temperature/pressure designs, advanced materials, and reheat steam cycles to PR boilers whenever it is appropriate, assuring you of the most up-to-date Largest Installed Base of Recovery design for your plant. Boilers in the World 2 Lowering the total cost of ownership B&W’s recovery boiler design includes features that lower the total cost of ownership with high availability, increased effi ciency and reduced maintenance. Reduced Constructi on Costs B&W’s longfl ow economizers (shown here) and generati ng banks provide eff ecti ve heat transfer and are modularized for easy installati on, reducing constructi on costs. High-Temperature Superheater Longfl ow economizer circulati on design margin for normal The boiler’s high-temperature super- • Two-gas/two-water pass arrangement and upset mill conditi ons. B&W heater metallurgy and modular heati ng provides eff ecti ve heat transfer from provides circulati on margin in the surface provide a fl exible design for the counter fl ow of gases across the design phase using COMO, our initi al and future mill operati ng tubes. proprietary computer modeling conditi ons. Because the primary • Bott le headers serve as integrally system. Our patented low pressure superheater is located downstream designed lift ing devices, eliminati ng drop internals, and B&W specified The latest process recovery (PR) boiler design from of the furnace cavity with steam expensive rigging beams or sleds. multi -lead ribbed tubes are key fl owing parallel to the fl ue gas, the components that add safety margin. Babcock & Wilcox Power Generation Group, Inc. • Tapered fi n design signifi cantly coolest available steam will be exposed reduces tube stresses and tube B&W is routi nely called upon by (B&W PGG), a subsidiary of The Babcock & Wilcox to the hott est gas and radiant heat leaks, compared with the experience both industrial and uti lity customers Company, is the leading-edge technology in the industry. from the furnace. This arrangement of other angled fi nned designs. to analyze and fix issues on non- provides eff ecti ve heat transfer and B&W boilers. With the largest installed base in the world of more minimizes tube metal temperatures, Longfl ow generati ng bank thereby reducing tube metal corrosion • Shop-assembled tube secti ons are Modern, Single-Drum Design than 350 recovery boilers, B&W PGG is committed to and improving reliability and safety. modularized to minimize Drum internals provide high steam the pulp and paper industry by helping today’s energy- constructi on ti me and expenses. purity to meet today’s steam turbine intensive mills become more competitive and profitable. Modularized Longflow Economizers • Full-length access cavity accommodates requirements, with a low pressure drop and Generati ng Bank retractable sootblowers for opti mal for additi onal circulati on safety B&W’s longflow economizers and margin. B&W’s welded, single-drum Our recovery boiler customers benefit from B&W PGG’s cleaning and maintenance. generati ng bank secti ons are shop- design addresses the need for high industry leadership in utility boiler design. We can apply modularized for lower installati on cost. Advanced Circulati on Design pressure and temperature steam utility boiler technology advancements such as high- They incorporate the latest design and For personnel safety, one of the most cycles with a large, conservatively sized temperature/pressure designs, advanced materials, technological improvements available criti cal recovery boiler component furnace. The location in front of the and reheat steam cycles to PR boilers whenever it is for recovery boilers. B&W’s robust designs is the natural circulati on furnace provides other benefits such design features have been selected appropriate, assuring you of the most up-to-date system. Due to the potenti al for smelt as extended drum length and simpler as the basis for current industry water reacti ons and the corrosive erection. design for your plant. standards. lower furnace environment, recovery boilers require ample 3 Other Multi -Level B&W’s QuantumAirTM Air Equipment System ISO-Surfaces of Gas Speed (70 ft /s) Twin Terti ary Air Emissions Lower NOX CO Carryover Liquor Air B&W’s QuantumAir system outperforms Liquor Gun other multi -level air systems in reducing NOX, CO and carryover. Generous Furnace Plan Area Secondary Air and Volume The QuantumAir system was developed by Primary Air uti lizing &B W’s COMO fl uid dynamic modeling program that enabled designers to opti mize the quanti ty and locati on of air levels for the most effi cient combusti on. Leading the industry with technology innovati ons COMO Modeling Program B&W’s industry-leading combusti on modeling (COMO) program for black liquor combusti on has led to numerous air system enhancements and modifi cati ons for improved boiler effi ciency and emissions. B&W leads the industry with state-of-the-art designs, equipment opti ons and opti mized operati ng conditi ons for your recovery boiler. Our proprietary COMO system has become the benchmark for other industry models. QuantumAir™ System B&W’s QuantumAir system can be upsets and auxiliary natural gas fuel B&W’s QuantumAir system – developed adapted for firing up to 85% black consumpti on. based on our industry experience and liquor solids. • Liquor air level reduces fi ne parti cle combustion modeling program for carryover above the liquor guns. black liquor combustion – sufficiently QuantumAir system benefi ts include: • Twin terti ary air level ports aligned lowers nitrogen oxides (NO ), carbon x • Increased staging reduces NOx with the liquor level ports further monoxide (CO) and carryover to help emissions. reduce parti cle carryover, improve reduce boiler emissions. The multi - • Reverse interlaced secondary air mixing and reduce emissions, level air system uses levels of primary ports minimize gas plume along the enabling you to extend the run ti me and secondary air in conjuncti on with furnace rear wall providing lower CO between water washes. close-coupled liquor air and twin terti- emissions and reduced maintenance. ary air. The system provides reduced • Single-level secondary air provides Improved Boiler Effi ciency emissions through increased staging excellent control of char bed com- Many features and capabiliti es of and higher air level elevations. busti on for both low and high solids our process recovery boilers provide fi ring, which minimizes operati onal 4 Tight Roof Casing Steam Drum Safety Reliability Lower Emissions Longfl ow Generati ng Bank and Economizer 100% Cooled Surface Maintenance Beams Conti nuous Trough Ash Removal High Solids Liquor Generous Delivery System and Furnace Plan Area QuantumAirTM System and Volume Twin Terti ary Air Lower Furnace Liquor Air Tube Protecti on Liquor Gun Secondary Air Rearwall Smelt Primary Air Spout Locati on PROCESS RECOVERY (PR) BOILER Liquor processing capacity up to or greater than 10,000,000 lb/day (4500 t/day) dry solids Steam pressure to 1850 psi (12.6 MPa) Steam temperature to 950F (510C) Fuel pulp mill liquor, soda, Kraft and other fuels Dual Sloped Floor Auxiliary fuels natural gas and/or oil Solids fi ring Up to 85% black liquor solids improved boiler effi ciency: B&W designs and manufactures an priority. Specifi c examples include: • Lower exit gas temperatures array of recovery boiler lower furnaces • Explosion relief point is located in • Increased air temperatures with metallurgy that includes: upper furnace, away from • Higher steam temperatures • composite tubes operati ng fl oors and personnel and pressures • weld overlay tubes for improved safety. • Reheat steam cycles • chromized and carbon steel pin studs • Increased number of fl oor beams • High solids fi ring provides greater support. High alloy composite furnace • Flexible seals and att achments Customized Liquor Delivery System panels are manufactured in B&W’s minimize stress-assisted corrosion For opti mal combusti on, reduced nuclear-grade manufacturing plant to and reduce maintenance. emissions and improved long-term provide a high-quality product for this maintenance, B&W offers a criti cal component. Our automated Auxiliary Fuel System – LM2100™ customized liquor delivery system pin studding machine provides a high- Retractable Burner that opti mizes liquor spray patt erns, quality, consistent pin stud patt ern B&W’s innovative LM2100 auxiliary droplet size and distributi on into the reducing plant maintenance, forced burner is designed for improved furnace.
Recommended publications
  • Boiler & Furnace Combustion Imaging
    IMPAC Non-Contact Infrared Temperature Sensors IMPACApplication Non-Contact Note Infrared Temperature Sensors BOILER & FURNACE COMBUSTION IMAGING The Opportunity The continued rise of worldwide electricity consumption has put an ever increasing demand on power generation facilities. With coal fired power plants, this demand results in challenges to increase production while minimizing environmental impact. Optimizing the performance of the downtime. In addition, lance systems coal boiler can provide immediate typically operate blindly; attempting benefits and maximize the Rankine to uniformly target all boiler tubes for cycle efficiency. One common problem cleaning. It is possible to reduce the is the buildup of fly ash and soot furnace power to obtain a visual inspec- on the boiler tube surfaces which tion of some tubes, but the efficiency reduces the heat exchange efficiency. loss during this process is significant. These deposits (Slag) can be removed Properly tuning the combustion process with lances, and similar systems, but can help reduce the buildup of tube identifying when to implement this deposits, and can minimize emissions. action can be difficult to estimate and However, switching coal composition routine periodic lance operation can can further complicate the tuning cause thermal stress to boiler tubes, process, and lead to varying fouling of leading to failure and unscheduled the boiler tubes. Our Solution Advanced Energy leverages more than 25 years of infrared thermal imaging experience to developing the BoilerSpection™ SD solutions specifically designed to address the monitoring of heat exchange tubes in coal fired boilers and furnaces. Using a custom narrowband 3.9μm filter and precision boroscope optics, we view through boiler flames and provide the clearest image of boiler tubes available.
    [Show full text]
  • Consider Installing a Condensing Economizer, Energy Tips
    ADVANCED MANUFACTURING OFFICE Energy Tips: STEAM Steam Tip Sheet #26A Consider Installing a Condensing Economizer Suggested Actions The key to a successful waste heat recovery project is optimizing the use of the recovered energy. By installing a condensing economizer, companies can im- ■■ Determine your boiler capacity, prove overall heat recovery and steam system efficiency by up to 10%. Many average steam production, boiler applications can benefit from this additional heat recovery, such as district combustion efficiency, stack gas heating systems, wallboard production facilities, greenhouses, food processing temperature, annual hours of plants, pulp and paper mills, textile plants, and hospitals. Condensing economiz- operation, and annual fuel ers require site-specific engineering and design, and a thorough understanding of consumption. the effect they will have on the existing steam system and water chemistry. ■■ Identify in-plant uses for heated Use this tip sheet and its companion, Considerations When Selecting a water, such as boiler makeup Condensing Economizer, to learn about these efficiency improvements. water heating, preheating, or A conventional feedwater economizer reduces steam boiler fuel requirements domestic hot water or process by transferring heat from the flue gas to the boiler feedwater. For natural gas-fired water heating requirements. boilers, the lowest temperature to which flue gas can be cooled is about 250°F ■■ Determine the thermal to prevent condensation and possible stack or stack liner corrosion. requirements that can be met The condensing economizer improves waste heat recovery by cooling the flue through installation of a gas below its dew point, which is about 135°F for products of combustion of condensing economizer.
    [Show full text]
  • Modu-Fire® Forced Draft Gas-Fired Boiler 2500 - 3000
    MODU-FIRE® FD 2500-3000 Rev. 1.1 (11/21/11) MODU-FIRE® FORCED DRAFT GAS-FIRED BOILER 2500 - 3000 C.S.A. Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam and Hot Water Boilers ASME Code, Section IV Certified by Harsco Industrial, Patterson-Kelley C.S.A. Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam and Hot Water Boilers Model #:_______ Serial #______________________ Start-Up Date: _______________________ Harsco Industrial, Patterson-Kelley 100 Burson Street East Stroudsburg, PA 18301 Telephone: (877) 728-5351 Facsimile: (570) 476-7247 www.harscopk.com ©2010 Harsco Industrial, Patterson Kelley Printed : 6/27/2012 MODU-FIRE® Forced Draft Boiler 1 INTRODUCTION ...................................................................................................... 4 2 SAFETY .................................................................................................................... 4 2.1 General ............................................................................................................................ 4 2.2 Training ............................................................................................................................ 4 2.3 Safety Features ................................................................................................................ 5 2.4 Safety Labels ................................................................................................................... 5 2.5 Safety Precautions ..........................................................................................................
    [Show full text]
  • Comparing Exchangers for Boiler Water/High Temperature Indirect Water Heaters HUBBELL Case Study 1
    HUBBELLHEATERS.COM Comparing Exchangers for Boiler Water/High Temperature Indirect Water Heaters HUBBELL Case Study 1 There are a few different options available if you are looking for a hydronic water heater that uses boiler water or high temperature hot water to heat potable water. One of the biggest decisions regarding boiler water heater types is determining which heat exchanger the system should utilize. Some models use a tube bundle heat exchanger while others use a plate and frame or brazed plate system. Tube bundle heat exchangers and plate and frame/brazed plate systems vary greatly in the way that they heat water and maintain a certain temperature. Both produce hot water, but in different ways. Hubbell offers a wide range of hydronic water heating systems for water to water applications, which can be customized to meet your needs. Let’s take a look at the heat exchangers for hydronic water heaters that should be considered by end users. Tube Bundle Tube bundles are designed to transfer heat from a, boiler water, solar water or high temperature hot water (HTHW) system to the domestic potable hot water system. The primary heat source, in this case boiler water or HTHW, travels through the tubing in the bundle within the shell, and transfers heat to the secondary system (potable water) without allowing either liquid to come into direct contact with the other. Tube bundle heat exchangers are ideal for older non-condensing water heating systems, specifically ones that use oil to produce heat. Older boilers are more suitable for the tube bundle type heat exchanger as they deal with higher non-condensing water temperatures.
    [Show full text]
  • Entrained-Flow Gasification of Black Liquor and Pyrolysis Oil
    LICENTIATE T H E SIS Department of Engineering Sciences and Mathematics Division of Energy Science Yawer Jafri Entrained-Flow Gasification of Black Liquor and Pyrolysis Gasification of Black Liquor and Pyrolysis Jafri Entrained-Flow Yawer ISSN 1402-1757 Entrained-Flow Gasification of ISBN 978-91-7583-761-1 (print) ISBN 978-91-7583-762-8 (pdf) Black Liquor and Pyrolysis Oil Luleå University of Technology 2016 Pilot-Scale and Equilibrium Modelling Studies of Catalytic Co-gasification Yawer Jafri Energy Engineering Licentiate Thesis Entrained-Flow Gasification of Black Liquor and Pyrolysis Oil Pilot-scale and Equilibrium Modelling Studies of Catalytic Co-gasification Yawer Jafri Energy Engineering Division of Energy Science Department of Environmental Sciences and Mathematics Luleå University of Technology a Printed by Luleå University of Technology, Graphic Production 2016 ISSN 1402-1757 ISBN 978-91-7583-761-1 (print) ISBN 978-91-7583-762-8 (pdf) Luleå 2016 www.ltu.se b Abstract The last couple of decades have seen entrained-flow gasification of black liquor (BL) undergo an incremental process of technical development as an alternative to combustion in a recovery boiler. The ability of the technology to combine chemical recovery with the production of clean syngas renders it a promising candidate for the transformation of chemical pulp mills into integrated forest biorefineries. However, techno-economic assessments have shown that blending BL with the more easily transportable pyrolysis oil (PO) can not only increase the energy efficiency of the conversion process for methanol production, but also remove a significant roadblock to commercial deployment by partially decoupling production capacity from BL availability.
    [Show full text]
  • Boiler & Cooling Tower Control Basics
    Boiler & Cooling Tower Control Basics By James McDonald, PE, CWT Originally Published: CSTR – May 2006 For those of us who have been around boilers and cooling towers for years now, it can be easy to forget how we may have struggled when we first learned about controlling the chemistry of boilers and cooling towers. After running all the chemical tests, where do you start when the phosphate is too high, conductivity too low, sulfite nonexistent, and molybdate off the charts? Even better, how would you explain this decision process to a new operator? Cycles of Concentration The first place you always start is cycles of concentration (cycles). You may measure cycles by measuring conductivity or chlorides. If everything else is running normally, when the cycles are too high, everything else should be proportionally too high. When the cycles are too low, everything else should be proportionally too low. When the cycles are brought back under control, the other parameters should come back within range too. Example We wish to run a boiler at 2,000 µmhos, 45 ppm phosphate, and 40 ppm sulfite; however, the latest tests show 1,300 µmhos, 29 ppm phosphate, and 26 ppm sulfite. The conductivity is 35% lower than what it should be. Doing the math ((45- 29)/45=35%), we see that the phosphate and sulfite are also 35% too low. By reducing boiler blowdown and bringing the conductivity back within control, the phosphate and sulfite should be within their control range too. Boilers 100 Beyond Cycles Whether we’re talking about boilers or cooling towers, we know if we reduce blowdown, cycles will increase, and if we increase blowdown, cycles will decrease.
    [Show full text]
  • An Overview of the State of Microgeneration Technologies in the UK
    An overview of the state of microgeneration technologies in the UK Nick Kelly Energy Systems Research Unit Mechanical Engineering University of Strathclyde Glasgow Drivers for Deployment • the UK is a signatory to the Kyoto protocol committing the country to 12.5% cuts in GHG emissions • EU 20-20-20 – reduction in EU greenhouse gas emissions of at least 20% below 1990 levels; 20% of all energy consumption to come from renewable resources; 20% reduction in primary energy use compared with projected levels, to be achieved by improving energy efficiency. • UK Climate Change Act 2008 – self-imposed target “to ensure that the net UK carbon account for the year 2050 is at least 80% lower than the 1990 baseline.” – 5-year ‘carbon budgets’ and caps, carbon trading scheme, renewable transport fuel obligation • Energy Act 2008 – enabling legislation for CCS investment, smart metering, offshore transmission, renewables obligation extended to 2037, renewable heat incentive, feed-in-tariff • Energy Act 2010 – further CCS legislation • plus more legislation in the pipeline .. Where we are in 2010 • in the UK there is very significant growth in large-scale renewable generation – 8GW of capacity in 2009 (up 18% from 2008) – Scotland 31% of electricity from renewable sources 2010 • Microgeneration lags far behind – 120,000 solar thermal installations [600 GWh production] – 25,000 PV installations [26.5 Mwe capacity] – 28 MWe capacity of CHP (<100kWe) – 14,000 SWECS installations 28.7 MWe capacity of small wind systems – 8000 GSHP systems Enabling Microgeneration
    [Show full text]
  • Why Does the Wisconsin Boiler and Pressure Vessel Code, 636 41
    Why does the Wisconsin Boiler and Pressure Vessel Code, SPS 341, regulate air compressors? By Industry Services Division Boiler and Pressure Vessels Program Almost everyone forms a definite picture in their mind when they hear the term “air compressor.” They probably think of a steel tank of some shape and dimension, with an electric motor, and an air pump mounted on top of the tank. To better understand the requirements of the Wisconsin Boiler Code, SPS 341, pertaining to air compressors, we need to have some common terminology. If a person wanted to purchase an “air compressor” at a hardware or home supply store, they would certainly be offered the equipment described above, consisting of three separate mechanical devices; the motor, the pump, and the storage tank. First, there is an electric motor, used to provide power to the device that pumps air to high pressure. This pumping device is the only part of the unit that is properly called an "air compressor." The compressor delivers high-pressure air to the third and final part of the mechanical assembly, the air storage tank; commonly called a pressure vessel. Because the pressure vessel receives pressurized air, this is the only part of the device described above that is regulated SPS 341. SPS 341 regulates pressure vessels when the pressure vessel's volume capacity is 90 gallons (12 cubic feet) or larger, and the air pressure is 15 pounds per square inch or higher. A typical pressure vessel of this size would be 24 inches in diameter and 48 inches long. In industrial settings, it is common practice to mount very large air compressors in a separate location from the pressure vessels.
    [Show full text]
  • TECHNICAL REPORT – PATENT ANALYSIS Enhancing Productivity in the Indian Paper and Pulp Sector
    TECHNICAL REPORT – PATENT ANALYSIS Enhancing Productivity in the Indian Paper and Pulp Sector 2018 TABLE OF contEnts ACKNOWLEDGEMENTS 10 EXECUTIVE SUMMARY 11 1 INTRODUCTION 13 2 OVERVIEW OF THE PULP AND PAPER SECTOR 15 2.1. Status of the Indian Paper Industry 15 2.2. Overview of the Pulp and Papermaking Process 20 2.3. Patenting in the Paper and Pulp Industry: A Historical Perspective 22 2.4. Environmental Impact of the Pulp and Paper Industry 25 3 METHODOLOGY 27 3.1. Search Strategy 27 4 ANALYSIS OF PATENT DOCUMENTS USING GPI 31 4.1. Papermaking; Production of Cellulose (IPC or CPC class D21) 31 4.2. Analysis of Patenting Activity in Different Technology Areas using GPI 38 5 ANALYSIS OF THE INDIAN PATENT SCENARIO WITHIN THE CONTEXT OF THIS REPORT 81 5.1. Analysis of Patents Filed in India 81 6 CONCLUDING REMARKS 91 REFERENCES 93 ANNEXURE 94 Annexure 1. Technologies related to paper manufacturing 94 Annexure 2. Sustainable/green technologies related to pulp and paper sector 119 Annexure 3. Emerging Technology Areas 127 List OF FIGURES Figure 2.1: Geographical Spread of Figure 4.11: (d) Applicant vs. Date of Indian Paper Mills .................................16 Priority Graph: Paper-Making Machines Figure 2.2: Share of Different Segments and Methods ........................................42 in Total Paper Production .......................19 Figure 4.11: (e) Applicant vs. Date of Figure 2.3: Variety Wise Production of Priority Graph: Calendars and Accessories ..43 Paper from Different Raw Materials ........19 Figure 4.11: (f) Applicant vs. Date of Figure 2.4: Different Varieties of Paper Priority Graph: Pulp or Paper Comprising Made from Various Raw Materials ..........19 Synthetic Cellulose or Non-Cellulose Fibres ..43 Figure 2.5: Diagram of a Process Block Figure 4.11: (g) Applicant vs.
    [Show full text]
  • 'Fan-Assisted Combustion' AUD1A060A9361A
    AUD1A060-SPEC-2A TAG: _________________________________ Specification Upflow / Horizontal Gas Furnace"Fan-Assisted 5/8" Combustion" 14-1/2" 13-1/4" AUD1A060A9361A 5/8" 28-3/8" 19-5/8" 5/8" 1/2" 4" DIAMETER FLUE CONNECT 7/8" DIA. HOLES ELECTRICAL 9-5/8" CONNECTION 4-1/16" 1/2" 3/4" 2-1/16" 7/8" DIA. K.O. 3-15/16" ELECTRICAL CONNECTION 8-1/4" (ALTERNATE) 13" 40" 3-3/4" 1-1/2" DIA. 3/4" K.O. GAS CONNECTION 2-1/16" (ALTERNATE) 28-1/4" 28-1/4" 3/4" 22-1/2" 23-1/2" 5-5/16" 3-13/16" 1-1/2" DIA. HOLE 3/8" GAS CONNECTION 2-1/8" FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 AUD1A060A9361A 4 - HIGH - Black 1426 1389 1345 1298 1236 1171 1099 1020 934 3 - MED.-HIGH - Blue 1243 1225 1197 1160 1113 1057 991 916 831 2 - MED.-LOW - Yellow 1042 1039 1027 1005 973 931 879 817 745 1 - LOW - Red 900 903 895 877 848 809 760 700 629 CFM VS. TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 800 900 1000 1100 1200 1300 1400 AUD1A060A9361A 56 49 44 40 37 34 32 © 2009 American Standard Heating & Air Conditioning General Data 1 TYPE Upflow / Horizontal VENT COLLAR — Size (in.) 4 Round RATINGS 2 HEAT EXCHANGER Input BTUH 60,000 Type-Fired Alum. Steel Capacity BTUH (ICS) 3 47,000 -Unfired AFUE 80.0 Gauge (Fired) 20 Temp.
    [Show full text]
  • Indoor Air Quality (IAQ): Combustion By-Products
    Number 65c June 2018 Indoor Air Quality: Combustion By-products What are combustion by-products? monoxide exposure can cause loss of Combustion (burning) by-products are gases consciousness and death. and small particles. They are created by incompletely burned fuels such as oil, gas, Nitrogen dioxide (NO2) can irritate your kerosene, wood, coal and propane. eyes, nose, throat and lungs. You may have shortness of breath. If you have a respiratory The type and amount of combustion by- illness, you may be at higher risk of product produced depends on the type of fuel experiencing health effects from nitrogen and the combustion appliance. How well the dioxide exposure. appliance is designed, built, installed and maintained affects the by-products it creates. Particulate matter (PM) forms when Some appliances receive certification materials burn. Tiny airborne particles can depending on how clean burning they are. The irritate your eyes, nose and throat. They can Canadian Standards Association (CSA) and also lodge in the lungs, causing irritation or the Environmental Protection Agency (EPA) damage to lung tissue. Inflammation due to certify wood stoves and other appliances. particulate matter exposure may cause heart problems. Some combustion particles may Examples of combustion by-products include: contain cancer-causing substances. particulate matter, carbon monoxide, nitrogen dioxide, carbon dioxide, sulphur dioxide, Carbon dioxide (CO2) occurs naturally in the water vapor and hydrocarbons. air. Human health effects such as headaches, dizziness and fatigue can occur at high levels Where do combustion by-products come but rarely occur in homes. Carbon dioxide from? levels are sometimes measured to find out if enough fresh air gets into a room or building.
    [Show full text]
  • The Affordable Heat-Circulating Fireplace Offering Style, Value and Performance. After a Hard Day in a Cold World…
    F I R E P L A C E S Y S T E M S The affordable heat-circulating fireplace offering style, value and performance. After a Hard Day in a Cold World… The NEW-AIRE FIREPLACE SYSTEM utilizes the basic principles of thermodynamics designed into any new high-efficient forced air furnace (radiant, conductive and convective heat transfer). By forcing air movement through a series of baffles in a specifically designed heat exchanger surrounding a steel firebox, ratings in excess of 200,000 BTU can be achieved in a full-fired condition. With 1050 cubic feet of air per minute at central HVAC static pressures, the NEW-AIRE fireplace easily matches the heat output of any high-efficiency furnace on the market today. Your home is the heart of your family’s life. A warm hearth is the gathering place that defines the spirit of the home. The NEW-AIRE fireplace, clad in brass and glass, provides both the traditional and functional elements needed in today’s life. Unlike stoves and inserts, the NEW-AIRE can be independently ducted to provide whole-house heating beyond the walls of the room in which it is installed. Certified to the International Mechanical Code, when ducted to induce heat into the central heating system, the NEW-AIRE SYSTEM efficiently provides the required heat for 4000 plus square foot homes. The NEW-AI Airtight /Airwash Door Control: heat loss, wood consumption, and smoke in the winter — air infiltration and ash smell in the summer. Makes any fireplace more efficient by controlling the “burn rate”.
    [Show full text]