L156 EZSERIES • LIGHTING MOGULBASEHIDFIXTURES

Class I, Div. 1 & 2 Groups , Class , Zone 1 & 2, Groups llB,llA Class l, Zone 1,AEx d IIB Class II, Div. 1 & 2, Groups ,, Class III, Div. 1 & 2 Suitable for wet locations Marine NEMA 3, 4, 4X Factory Sealed

Listed - File E10514 and E91793

Certified - File LR11713

FEATURES-SPECIFICATIONS

maintenance. See pages L196-197 for protector, and fuse kits. trunnion mounted fixtures (See page L160 for details) • Factory sealed—No external seal Compliances HOSTILELITE® EZ fixtures are now needed. Simply wire mounting cap • UL-844 Electric Lighting Fixtures for available with Pulse Start Metal Halide and thread on fixture to install use in Hazardous Locations ballasts. Pulse Start systems provide higher and better maintained light out- • Corrosion resistant—Copper-free alu- • UL Marine Type Electric Lighting put with longer life compared standard minum die cast construction. Baked Fixtures powder epoxy finish, electrostatically metal halide systems. Pulse start and • UL-1598 Standard for HID Lighting standard Metal Halide lamps and applied. Exposed hardware is 316 grade stainless steel Fixtures ballasts are not interchangeable. • Accessories—Available with or with- • CSA C22.2 no. 137-M1981 Electric Applications out guard, standard dome or angle Luminaires for use in Hazardous ® HOSTILELITE EZ Series mogul base reflector Locations fixtures are designed for installations • Options—EZ Series fixtures can be • CSA C22.2 no. 94-1976 Special where moisture, dirt, dust, corrosion purpose enclosure and vibration may be present, or NEMA specified with instant restart for HPS lamps, auxiliary quartz circuit, ballast 3 and 4x areas where wind, water, • NEMA 3, 4, 4x, 7CD, 9EFG snow or high ambients can be ex- Catalog Number Logic pected. They can be used in locations EZ 0 00 0 00 0 - 00 (CEN*) made hazardous due to the presence of flammable or explosive gases, Series Constant vapors and combustible dusts as Options defined by the NEC. Lamp Type —Auxiliary Quartz Typical applications include classified —High Pressure Sodium Standby areas such as paint manufacturing —Metal Halide —Instant Restrike plants, ammunition facilities, oil and P—Pulse Start Metal Halide (150W HPS Max) gas producing and refining plants, BP—Ballast Protector Lamp Wattage —Paint Spray off-shore and dockside installations, 05—50 Watt HPS tank farms, pipeline pumping stations (50, 70, 100W HPS, 07—70 Watt HPS/MH 100W MV, 70, 100, MH) and marine loading and fuel transfer 10—100 Watt HPS/MH terminals. EB—Eyebolts1 15—150 Watt HPS/MHP SU103—Assembled /Lamp Features 17—175 Watt MH/MHP2 • Three light sources—High Pressure 20—200 Watt HPS/MHP Guard Sodium (50-400W), Metal Halide 25—250 Watt HPS/MH/MHP2 G—Omit G if guard (70-400W) and Pulse Start Metal 32—320 Watt MHP is not required Halide (175-400W) 35—350 Watt MHP • HOSTILELITE® EZ fixtures are now 40—400 Watt HPS/MH/MHP2 Mounting Type available with Pulse Start Metal A2—3/4" Pendant Voltage Halide ballasts A3—1" Pendant 0—Quadri-Volt, 60 Hz. (120, 208, 240, 277) X2—3/4" Ceiling • Mounting choice—Pendant, ceiling, 5—480 Volts, 60 Hz. 25˚ stanchion or 90˚ wall mount, all X3—1" Ceiling 6—TriTap Canada (120, 277, 347), 60 Hz. B2—3/4" Bracket with “wireless” design that allows fast, 7—220V, 60Hz easy fixture installation or removal for B3—1" Bracket 8—220/240 Volt, 50 Hz. D4—1-1/4"/1-1/2" Stanchion 9—Special (Specify) *CEN (CENELEC) Approved option available on some models. See page L164 for more information. 1 Two eyebolts plus 12" of connecting chain included. 2 175,250 and 400W MH EXPORT ONLY (EISA LAW). V Consult factory for available lamp and voltage combinations. L162 EZSERIES • LIGHTING BALLASTHOUSINGWITHGLOBESUPPORTASSEMBLY

NOTE: See pages L98-99 for ballast data & fuse kit information. Housing Globe & Globe Support Assemblies

FEATURES-SPECIFICATIONS

HPSHOUSINGGLOBE&GLOBESUPPORTASSEMBLIES 1 METALHALIDEHOUSINGGLOBE&GLOBESUPPORTASSEMBLIES1 ANSILAMP CATALOG ANSILAMP CATALOG WATTS VOLTAGE WATTS VOLTAGE TYPE NUMBER TYPE NUMBER 120, 208, 240, 277/60Hz EZS050 120, 208, 240, 277/60Hz EZH070 50 S-68/HPS 220, 240V/50Hz EZS058 120, 277, 347V/60Hz EZH076 70 -98/MH 120, 208, 240, 277/60Hz EZS070 480 60Hz EZH075 480 60Hz EZS075 220/240V/50Hz EZH078 70 S-62/HPS 120, 277, 347/60Hz EZS076 120, 208, 240, 277/60Hz EZH100 220, 240V/50Hz 120, 347V/60Hz EZH106 EZS078 100 M-90/MH 120, 208, 240, 277/60Hz EZS100 120, 220, 240V/50Hz EZH108 480 60Hz EZS105 480 60Hz EZH105 100 S-54/HPS 120, 277, 347/60Hz EZS106 120, 208, 240, 277/60Hz EZH170 220, 240V/50Hz EZS108 480 60Hz EZH175 175 M-57/MH 120, 208, 240, 277/60Hz EZS150 120, 277, 347V/60Hz EZH176 480 60Hz EZS155 220, 240V/50Hz EZH178 150 S-55/HPS 120, 277, 347/60Hz EZS156 120, 208, 240, 277/60Hz EZH250 220, 240V/50Hz EZS158 480 60Hz EZH255 250 M-58/MH 120, 208, 240, 277/60Hz EZS250 120, 277, 347V/60Hz EZH256 480 60Hz EZS255 220, 240V/50Hz EZH258 250 S-50/HPS 120, 277, 347/60Hz EZS256 120, 208, 240, 277/60Hz EZH400 220, 240V/50Hz EZS258 480 60Hz EZH405 400 M-59/MH 120, 208, 240, 277/60Hz EZS400 120, 277, 347V/60Hz EZH406 480 60Hz EZS405 220, 240V/50Hz EZH408 400 S-51/HPS 120, 277, 347/60Hz EZS406 220, 240V/50Hz EZS408 PULSESTARTHOUSINGGLOBE&GLOBESUPPORTASSEMBLIES ANSILAMP CATALOG VOLTAGE 1 HPS and MH assemblies may be ordered with the CEN (CENELEC) suffix; WATTS TYPE NUMBER see page L164 for more information. 120, 208, 240, 277/60Hz EZP170 480 EZP175 175 M137/MHP 2 120, 277, 347V/60Hz EZP176 220, 240V/50 Hz EZP178 120, 208, 240, 277/60Hz EZP250 480 EZP255 250 M138/MHP 120, 277, 347V/60Hz EZP256 220, 240V/50Hz EZP258 120, 208, 240, 277/60Hz EZP320 480 EZP325 320 M132/MHP 120, 277, 347V/60Hz EZP326 220, 240V/50Hz EZP328 120, 208, 240, 277/60Hz EZP350 480 EZP355 350 M131/MHP 120, 277, 347V/60Hz EZP356 220, 240V/50Hz EZP358 120, 208, 240, 277/60Hz EZP400 480 EZP405 400 M135/MHP 120, 277, 347V/60Hz EZP406 220, 240V/50Hz EZP408

2For 150 Watt, change “7” to “5” in catalog number. Example EZP150. L164 EZSERIES • LIGHTING CLASSIAPPLICATIONDATAFORHAZARDOUSLOCATIONS

EZ HAZARDOUS LOCATION DATA—CLASS I, DIVISIONS 1 & 2 124 SUPPLY CLASSI,DIVISIONS1&2 LAMP RATEDWIRE MAXIMUMSURFACETEMPERATURE UL/CSA AMBIENTSUITABLE CEN Option SERIESTYPEWATTS °C FOR °C TEMP.I.D. TEMP.I.D. UL/CSA MIN.W/OQTZ.W/QTZ.3 GROUPS Applications 40 85 T5 T4 C,D Killark EZ series fixtures are available with a 50 55 85 T5 /AC,D European “Certificate of Conformity” from 65 85 T4A N/A C,D PTB (Physikalisch-Technische 40 85 T5 T4 C,D Bundesanstalt), the approval agency 70 55 85 T5 N/AC,D based in Germany. Fixtures with this rating 65 85 T4A N/A C,D will be useful for Original Equipment EZSHPS 40 85 T5 T4 C,D Manufacturers and others who build and 100 55 85 T5 N/AC,D ship apparatus into European markets. 65 85 T4A N/A C,D This approval is granted by PTB with the 40 85 T4A T4 C,D use of a special ground lug and label. 150 55 85 T4A N/A C,D Fixtures carrying an EEx d llB approval are 65 85 T4 N/AC,D automatically granted an IP54 (ingress pro- 40 85 T3C T3C C,D 250 tection) rating. See Temperature Code 55 85 T3C N/A C,D chart below for PTB certified ratings. Killark 400 40 85 T3C T3C C,D EZ fixtures with the PTB rating and labels 40 85 T4A N/A C,D still carry all UL & CSA ratings. 70 55 85 T4A N/A C,D 65 85 T4A N/A C,D Fixture housing/globe/globe support 40 85 T4A N/A C,D assemblies (e.g. EMS050 CEN) may be 100 55 85 T4A N/A C,D ordered with the CEN suffix. Complete fix- EZHMH 65 85 T4A N/A C,D ture numbers, with the CEN suffix, will be 40 85 T4 T3C C,D shipped with the mounting boxes, guards 175 55 85 T4 N/AC,D and accessories as component parts. 40 85 T3C T3C C,D Reflectors and other accessory parts, as 250 55 85 T3C N/A C,D listed on pages L144-145, may be used. 400 40 85 T3A T3A C,D Killark fixtures are NPT tapped and 40 85 T4 T3C C,D plugged with at least one conduit 150 or 175 55 85 T4 N/AC,D hole open. 40 85 T3C T3C C,D 250 Compliances EZPMHP 55 25 T3C N/A C,D • EN 50014:1992 320 40 85 T3A T3A C,D • EN 50018:1994 350 40 85 T3A T3A C,D 400 40 85 T3A T3A C,D EEx d IIBT6 (orT5-T2) PTB No. Ex-98.E.1076 Notes for Class I, II, III Application Data Tables. 1Instant restrike limited to 55°C ambient maximum. MAXIMUM AMBIENT TEMPERATURE RANGE -20°C TO 40°C 2Temperature code ID marked with an asterisk on Class table are listed for simultaneous * TEMPERATURE use in Class I, Groups C, D, and Class II, Groups E, F, G or Groups E, F. TYPEOF TYPEOF FORMOF MAXIMUM LUMINAIRE ENCLOSURE THELAMP WATTAGE CLASS 3Fixtures marked “N/A” not suitable for Class ll applications when supplied with auxiliary quartz. EZH50 EZO25 ED28/M-110 50W T4 4See Class II table for fixtures suitable for locations having deposits of readily combustible EZH70 EZO25 ED28/M-98 70W T4 paint residue (paint spray booths). EZH10 EZO25 ED28/M-90 100W T4 Do not install where marked operating temperature exceeds ignition temperature of haz- EZH15 EZO25 ED28/M-102 150W T4 ardous atmosphere. EZH17 EZO25 ED28/M-57 175W T4 EZH25 EZO25 ED28/M-58 250W T3 EZH40 EZO40 ED37/M-59 400W T3 EZS50 EZO25 ED23-1/2/S-68 50W T4 See page L165 for Class II, III tables. EZS70 EZO25 ED23-1/2/S-62 70W T4 EZS10 EZO25 ED23-1/2/S-54 100W T4 EZS15 EZO25 ED23-1/2/S-55 150W T4 EZS25 EZO40 ED18/S-50 250W T3 EZS40 EZO40 ED18/S-51 400W T3 EZSERIES • LIGHTING L165 CLASSII/IIIAPPLICATIONDATAFORHAZARDOUSLOCATIONS

EZHAZARDOUSLOCATIONDATA 1 –CLASS II & III, DIVISIONS 1 & 2 1 2 SUPPLY CLASS II, DIV. 1 & 2, MAX. SURFACE CLASS III, DIV. 1 & 2 U.L. PAINT UL/CSA UL/CSA LAMP RATED WIRE UL-595 TEMP. UL/CSA SUITABILITY UL/CSA SUITABILITY SPRAY TYPE 3 TYPE 4 AMBIENT MARINE SUITABLE TEMP. I.D. TEMP. I.D. GROUPS (HOSEDOWN) LAMP °C SUITABILITY4 (RAINTIGHT) FOR C° W/ QTZ. WITH QTZ3 W/OQTZ. WITH QTZ3 W/O QTZ. WITH QTZ.3 40 85 T3C* T3B* E,F E,F,G YES YES YES YES YES YES EZS HPS 50 55 85 T3C* N/A E,F,G N/A YESNOYESNO YES YES 85 T3B* N/A E,F,G N/A YESNOYESNO YES YES 85 T3C* T3B* E,F,G E,F,G YESNOYESYESYES YES EZS HPS 70 55 85 T3C* N/A E,F,G N/A YESNOYESNO YES YES 65 85 T3B* N/A E,F,G N/A YESYESYESNO YES YES 40 85 T3C* T3B* E,F,G E,F,G YESNOYESYESYES YES EZS HPS 100 55 85 T3C* N/A E,F,G N/A YESNOYESNO YES YES 65 85 T3B N/A E,F,G N/A YESYESYESNO YES YES 40 85 T3C* T3B* E,F,G E,F,G YESYESYESNO YES YES EZS HPS 150 55 85 T3C* N/A E,F, N/A YESYESYESNO YES YES 65 85 T3B* N/A E,F,G N/A YESYESYESNO YES YES EZS HPS 250 40 85 T3 T3 E,F E,F NONOYESNO YES YES EZS HPS 400 40 85 N/A N/A N/A N/A NONOYESNO YES YES 40 85 T4A N/A E,F, N/A YESNOYESYESYES YES EZH MH 70 55 85 T4 N/A E,F,G N/A YESNOYESNO YES YES 65 85 T3C N/A E,F, N/A YESNOYESNO YES YES 40 85 T4A N/A E,F,G N/A YESNOYESYESYES YES EZH MH 100 55 85 T4 N/A E,F,G N/A YESNOYESNO YES YES 65 85 T3C N/A E,F,G N/A YESNOYESNO YES YES EZH MH 175 40 85 T3C* T3A* E,F,G N/A YESNOYESNOYES YES 55 85 T3C* N/A E,F,G N/A YESNOYESNO YES YES EZH MH 250 40 85 N/A N/A N/A N/A NONOYESNO YES YES EZH MH 400 40 85 N/A N/A N/A N/A NONOYESNO YES YES EZP MHP 150 or 40 85 T3C* T3A* E,F,G EF YESNOYESNO YES YES 175 55 85 T3C* N/A E,F,G N/A YESNOYESNO YES YES EZP MHP 250 40 85 N/A N/A N/A N/A NONOYESNO YES YES EZP MHP 320, 350 40 85 N/A N/A N/A N/A NONOYESNO YES YES EZP MHP 400 40 85 N/A N/A N/A N/A NONOYESNO YES YES

Notes for Class I, II, III Application Data Tables. 1Instant restrike limited to 55°C ambient maximum. * 2Temperature code ID marked with an asterisk on Class ll table are listed for simultaneous use in Class I, Groups C, D, and Class II, Groups E, F, G or Groups E, F. 3Fixtures marked “NO” or “N/A” are not suitable for Class ll or II applications when supplied with auxiliary quartz. 4Suitability for locations having deposits of readily combustible paint residue (paint spray booths). Do not install where marked operating temperature exceeds ignition temperature of hazardous atmosphere.

L TABLE N.E.C. 500-5 ( d) See page L164 for Class l data. I.D. NUMBER DEGREESC DEGREESF T1 450 842 T2 300 572 T2A 280 536 T2B 260 500 T2C 230 446 T2D 215 419 T3 200 392 T3A 180 356 T3B 165 329 T3C 160 320 T4 135 275 T4A 120 248 T5 100 212 T6 85 185