Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP

Total Page:16

File Type:pdf, Size:1020Kb

Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP NIST Special Publication 250-81 Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP G. F. Strouse NIST Special Publication 250-81 Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP G. F. Strouse Chemical Science and Technology Laboratory Process Measurements Division Thermometry Group January 2008 U.S. Department of Commerce Carlos M. Gutierrez, Secretary National Institute of Standards and Technology James M. Turner, Deputy Director ii Certain commercial entities, equipment, or materials may be identified in this document in order to describe an experimental procedure or concept adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the entities, materials, or equipment are necessarily the best available for the purpose. National Institute of Standards and Technology Special Publication 250-81 Natl. Inst. Stand. Technol. Spec. Publ. 250-81, 79 pages (2008) CODEN: NSPUE2 Errata A single-digit misprint was found in Coefficient A5 in Table 3, printed as -0.61893395 instead of -0.61899395. This publication has been corrected from the original published version of January 2008. (February 2014 correction) 1 Introduction ............................................................................................................................. 1 2 ITS-90 Overview (Ar TP to Ag FP) ....................................................................................... 1 2.1 ITS-90 equations ............................................................................................................. 2 2.2 ITS-90 thermometer specifications ................................................................................. 4 3 Description of Services ........................................................................................................... 4 3.1 Types of thermometers calibrated ................................................................................... 4 3.2 Calibration temperature ranges ....................................................................................... 5 3.3 Selecting a calibration temperature range ....................................................................... 7 3.4 Requesting an SPRT calibration ..................................................................................... 7 3.5 Guide for shipping SPRTs .............................................................................................. 7 3.6 Turn-around time ............................................................................................................ 8 3.7 ISSC database ................................................................................................................. 8 3.8 Rejected SPRTs .............................................................................................................. 8 3.9 Special Tests / Requests .................................................................................................. 9 4 Calibration System Overview ................................................................................................. 9 4.1 Calibration process.......................................................................................................... 9 4.2 Fixed point cells ............................................................................................................ 14 4.2.1 Fixed-point cell specifications .............................................................................. 14 4.2.2 ITS-90 fixed-point cell corrections ....................................................................... 18 4.3 Fixed-point cell maintenance systems .......................................................................... 20 4.3.1 Liquid baths .......................................................................................................... 20 4.3.2 Furnaces ................................................................................................................ 20 4.3.3 Maintenance system thermal characteristics ......................................................... 21 4.4 SPRT measurement system........................................................................................... 24 4.5 Measurement software .................................................................................................. 25 5 ITS-90 SPRT Calibration Methods ....................................................................................... 25 5.1 SPRT stabilization methods .......................................................................................... 25 5.2 Calibration by fixed points............................................................................................ 27 5.2.1 Ag FP .................................................................................................................... 27 5.2.2 Al FP ..................................................................................................................... 28 5.2.3 Zn FP ..................................................................................................................... 29 5.2.4 Sn FP ..................................................................................................................... 30 5.2.5 In FP ...................................................................................................................... 31 5.2.6 Ga TP .................................................................................................................... 32 5.2.7 TPW (H2O TP) ...................................................................................................... 33 5.2.8 Hg TP .................................................................................................................... 35 5.2.9 Ar TP ..................................................................................................................... 36 5.3 Calibration report .......................................................................................................... 37 5.4 On receipt of a NIST calibrated SPRT ......................................................................... 37 5.5 Determining the SPRT re-calibration interval .............................................................. 37 6 Internal Measurement Assurance .......................................................................................... 38 6.1 Fixed-point cell element ............................................................................................... 39 6.1.1 Sample purity parameter ....................................................................................... 39 6.1.2 Phase transition repeatability parameter ............................................................... 41 iv 6.1.3 Constant cell pressure parameter .......................................................................... 41 6.1.4 Cell corrections parameter .................................................................................... 41 6.1.5 Design/Assembly parameter ................................................................................. 41 6.2 Furnace/Maintenance system element .......................................................................... 41 6.2.1 Vertical gradient parameter................................................................................... 41 6.2.2 Set-point control parameter................................................................................... 41 6.2.3 Fixed-point cell interaction parameter .................................................................. 42 6.3 SPRT element ............................................................................................................... 42 6.3.1 Heat-flux parameter .............................................................................................. 42 6.3.2 Immersion depth parameter .................................................................................. 43 6.3.3 Self-heating parameter .......................................................................................... 43 6.3.4 Stability parameter ................................................................................................ 43 6.3.5 Wetness parameter ................................................................................................ 44 6.3.6 Contamination parameter ...................................................................................... 44 6.3.7 Light-Piping parameter ......................................................................................... 44 6.4 Measurement system element ....................................................................................... 45 6.4.1 Repeatability parameter ........................................................................................ 45 6.4.2 Non-Linearity parameter ....................................................................................... 45 6.4.3 Ratio-error parameter ............................................................................................ 45 6.4.4 Ohm parameter...................................................................................................... 45 6.4.5 AC quadrature parameter ...................................................................................... 46 6.4.6 Current parameter ................................................................................................. 46 6.4.7 Number of readings parameter.............................................................................
Recommended publications
  • AOAC Official Method 2011.25 Insoluble, Soluble, and Total Dietary Fiber in Foods
    AOAC Official Method 2011.25 supplies/fisherbrand.html) or 250 mL polypropylene bottles with Insoluble, Soluble, and Total Dietary Fiber in Foods polypropylene caps. Enzymatic-Gravimetric-Liquid Chromatography (c) Fritted crucible.—Gooch, fritted disk, Pyrex® 50 mL, First Action 2011 pore size, coarse, ASTM 40–60 µm (Corning No. 32940-50C® [Applicable to plant material, foods, and food ingredients or equivalent; http://www.labplanet.com/corning-crucible-gooch- consistent with CODEX Alimentarius Commission high-c-50-ml-32940-50c.html). Prepare four for each sample as Definition adopted in 2009 and modified slightly in 2010 follows: Ash overnight at 525°C in muffle furnace. Cool furnace to (ALINORM 09/32/REP and ALINORM 10/33/REP, respectively), 130°C before removing crucibles to minimize breakage. Remove including naturally occurring, isolated, modified, and synthetic any residual Celite and ash material by using a vacuum. Soak in 2% polymers meeting that definition.] cleaning solution, C(i), at room temperature for 1 h. Rinse crucibles See Tables 2011.25A–H for the results of the interlaboratory with water and deionized water. For final rinse, use 15 mL acetone study supporting acceptance of the method. and air dry. Add approximately 1.0 g Celite to dried crucibles and A. Principle dry at 130°C to constant weight. Cool crucible in desiccators for approximately 1 h and record mass of crucible containing Celite. A method is described for the measurement of insoluble, (d) Filtering flask.—Heavy-walled, 1 L with side arm. soluble, and total dietary fiber (IDF, SDF, and TDF, respectively), (e) Rubber ring adaptors.—For use to join crucibles with inclusive of the resistant starch (RS) and the water:alcohol soluble filtering flasks.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • MT 058 Linkam Stage THMS600 And
    Ref : LINKAM – EXAMINA - THMS 600 DESCRIPTION The THMS600 system can be programmed and controlled by either the TMS94,TP94 or CI94 temperature programmers. In order to cool the stage below ambient temperature, the LNP94/2 or LNP94/1 must be used. This manual describes the set up for a THMS600 heating/freezing stage connected to a TMS94 programmer and THM-LNP94/2 automatic cooling pump. The TP94 and CI94 have similar connections to the TMS94 and should be easy to set up following the procedures within this manual. The THM-LNP94/2 is similar to the THM-LNP94/1 THM-LNP94/2 Cooling Pump and Dewar except that the THM-LNP94/2 uses an I 2C cable to communicate with the temperature programmer, so that it automatically selects TMS94 Temperature Programmer the correct pumping speed specific to the programmed rate. THMS600 Microscope Stage If you have any problems with setup or with the operation of the equipment, please contact Linkam Scientific, we will be happy to help. - 1 - Ref : Complete list of THMS600 Accessories Part Part Name Part Description No. 9521 STGLD THMS600 stage connection lead 7017 PVC1 Plastic tube for stage body water cooling 2200 WGI Water/Gas Valve Insert 2202 WVC Water/Gas Valve Connector 2208 SGC Stage Gas Port Valve 9566 VS Complete Valve Set 9573 MGF Set of 6 Magnetic Feet for Mounting Stage 2061 SRR Silicon Rings for Lid and Base 9579 RI17 Stainless Steel Ring Set 2231 TCH Tube Clip Holder (for Nitrogen de-fogging stage lid tube) 2624 ORTHMS Set of O-Rings for THMS Stage Body and Lid 2220 THMS/CC Crucible Carrier for
    [Show full text]
  • Solutions for Primary & Secondary Laboratories
    1 üThe Source for Calibration Professionals Solutions for Primary & Secondary Laboratories Temperature Calibration Equipment & Services - Required calibration point for range Copper Freeze 1084.62ºC Point Cells COPPER FREEZES 1064.180ºC GOLD FREEZES Silver Freeze Point Cells 961.7800ºC Aluminium Freeze Point Cells 660.3230ºC ITL 17705 or 17702C or 17705 ITL hermometer 962 & 96178 & 962 hermometer T Zinc Freeze Point Cells 419.5270ºC ITL 17702B or ITL 17706 ITL or 17702B ITL Tin Freeze Point Cells 231.9280ºC 465 Indium Freeze 156.5985ºC hermocouple Point Cells ITL 17707 or 17702A or 17707 ITL T hermometer 909 & 670 & 909 hermometer T ITL 17701 ITL ITL 17703 ITL emperature Standard Platinum Resistance Resistance Platinum Standard emperature T Gallium Melt Point Cell & Apparatus 29.76460ºC Gold / Platinum Platinum / Gold High Triple Point Water Cell & Apparatus 0.010000ºC Mercury Triple Point Cell & Apparatus -38.83440ºC Boiling Point -189.3442ºC Standard Platinum Resistance Resistance Platinum Standard Comparator for TRIPLE POINT OF ARGON Argon, Nitrogen or Oxygen -218.7916ºC TRIPLE POINT OF OXYGEN -248.5939ºC TRIPLE POINT OF NEON -259.3467ºC TRIPLE POINT OF HYDROGEN -273.1500ºC Isotech ITS-90 ABSOLUTE ZERO ITS-90 Metrology Temperature Acceptable Furnaces Scale Thermometer Ranges For full details, contact Isothermal Technology Limited, Pine Grove, Southport, Merseyside PR9 9AG England Telephone +44 (0)1704 543830 Fax +44 (0)1704 544799 Email [email protected] Web www.isotech.co.uk Contents Metrology Instruments .........................................Inside Front The Best Comparison Calibration Equipment ........... 54 - 55 Introduction .................................................................. 4 - 5 Nitrogen Boiling Point Apparatus .................................. 57 Model 461 Simple Liquid N2 Apparatus ........................ 58 Primary ITS-90 Standards Model 459 Cryostat ....................................................
    [Show full text]
  • Laboratory Equipment Used in Filtration
    KNOW YOUR LAB EQUIPMENTS Test tube A test tube, also known as a sample tube, is a common piece of laboratory glassware consisting of a finger-like length of glass or clear plastic tubing, open at the top and closed at the bottom. Beakers Beakers are used as containers. They are available in a variety of sizes. Although they often possess volume markings, these are only rough estimates of the liquid volume. The markings are not necessarily accurate. Erlenmeyer flask Erlenmeyer flasks are often used as reaction vessels, particularly in titrations. As with beakers, the volume markings should not be considered accurate. Volumetric flask Volumetric flasks are used to measure and store solutions with a high degree of accuracy. These flasks generally possess a marking near the top that indicates the level at which the volume of the liquid is equal to the volume written on the outside of the flask. These devices are often used when solutions containing dissolved solids of known concentration are needed. Graduated cylinder Graduated cylinders are used to transfer liquids with a moderate degree of accuracy. Pipette Pipettes are used for transferring liquids with a fixed volume and quantity of liquid must be known to a high degree of accuracy. Graduated pipette These Pipettes are calibrated in the factory to release the desired quantity of liquid. Disposable pipette Disposable transfer. These Pipettes are made of plastic and are useful for transferring liquids dropwise. Burette Burettes are devices used typically in analytical, quantitative chemistry applications for measuring liquid solution. Differing from a pipette since the sample quantity delivered is changeable, graduated Burettes are used heavily in titration experiments.
    [Show full text]
  • Resistance Thermometers Tailor-Made Sensors. Worldwide
    Resistance thermometers Tailor-made sensors. Worldwide. TAILOR-MADE SENSORS Place of location ➜ 01. ░░░░░░░░░░░░░ EPHY-MESS SENSORS ADD EFFICIENCY AND SAFETY TO YOUR SYSTEM Globality and loyalty to location EPHY-MESS GmbH is a competent solution partner of all manufac- cision products and solutions, innovative engineering and continuous turers of electrical machines and drive technology. As a medium-sized exploratory urge. family owned company, we consult, develop and produce for our cus- tomers individual sensor solutions for safety and control requirements. Always anchored in the vicinity of Wiesbaden, EPHY-MESS has, since the turn of the millennium, risen to become a global provider As a premium manufacturer and distributor of tailor-made industrial which now supplies markets in over 40 countries at an export ratio measurement and sensor technology, the company has taken a lead- of 40 percent. ing position in Germany in its more than 60-year history through pre Yours Claudia & Andreas Becker 2 | Resistance thermometers EPHY-MESS GmbH Rev. 20180108 EPHY-MESS GmbH Resistance thermometers | 3 „Schrift“ > „Sonderzeichen einfügen“ > „Marken“ > „Aktuelle Seitenzahl“ „Schrift“ > „Sonderzeichen einfügen“EPHY-MESS > „Marken“ GmbH > „Aktuelle Lieferprogramm Seitenzahl“ | 3 02. HOW TO CONTACT EPHY-MESS EPHY-MESS GmbH, Berta-Cramer-Ring 1, 65205 Wiesbaden Content Telephone +49 6122 9228-0 [email protected] Fax +49 6122 9228-99 www.ephy-mess.de 03. CONTENT Page Page ➜ CERTIFIED ACCORDING TO Tailor-made sensors 12. Slot resistance thermometers NWT bifilar 24 ░░░░░░░░░░░░░ 01. Globality and loyalty to location 03 13. Slot resistance thermometers NWT chip 34 02. How to contact EPHY-MESS, 04 14. Screw-in resistance thermometers LTH 40 certificates, trade associations 15.
    [Show full text]
  • Temperature Sensor Instruction Manual
    TD-1002b INSTRUCTION MANUAL Temperature Sensor Instruction Manual OKAZAKI MANUFACTURING COMPANY Instruction Manual OKAZAKI MANUFACTURING COMPANY 1-3 GOKODORI 3-CHOME, CHUOU-KU, KOBE 651-0087, JAPAN PHONE : 078-251-8200 FAX : 078-251-8210 http://www.okazaki-mfg.com/index.html E-mail : [email protected] Note : 1) All provisions are subject to change without any notice. 2) This manual is prepared with the greatest possible care, but if any problems, please do not hesitate to contact us. OKAZAKI MANUFACTURING COMPANY INSTRUCTION MANUAL TD-1002b Index CHAPTER 1 BEFORE TO USING 2 1.1 ATTENTION TO SAFETY ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 2 1.2 WHEN BREAK DOWN ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5 CHAPTER 2 INTRODUCTION 6 CHAPTER 3 TEMPERATURE SENSOR OVERVIEW 7 3.1 TYPES OF TEMPERATURE SENSORS ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 3.2 MEASUREMENT PRINCIPLE OF THERMOCOUPLE ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 3.3 TYPES OF THERMOCOUPLE ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 3.4 MEASUREMENT PRINCIPLE OF RESISTANCE THERMOMETER SENSOR ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 3.5 TYPES OF RESISTANCE THERMOMETER SENSOR ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 10 CHAPTER 4 PRIOR TO INSTALLATION 11 4.1 TO CHECK ITEMS AFTER UNPACKING ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 11 4.2 PRECAUTIONS FOR STORING THE
    [Show full text]
  • The Platinum Resistance Thermometer
    The Platinum Resistance Thermometer A REVIEW OF ITS CONSTRUCTION AND APPLICATIONS By liodney Price The platinum resistance thermometer is a versatile instrument for temperature measurement in the range from - 200" to 1000°C. It is used both for precision measurements of the highest accuracy and for routine industrial work. This article discusses the development and construction of resistance thermometers and their uses in a wide range of industries. The platinum resistance thermometer-in ment, and where there are several measuring which the principle of measurement is the points and readings are required at one central variation in the resistance of a platinum wire instrument panel. In addition to the measure- as a function of temperature-is generally ment of elevated temperatures, the platinum accepted as the most accurate temperature resistance thermometer is also finding a measuring instrument available. Its sensitivity number of applications where the accurate and reliability are evident from the fact that determination or control of sub-zero tem- it was first used in 1928 to define the Inter- peratures is needed. national Temperature Scale from -190" to The operation of the resistance ther- 660°C and has thus been the primary inter- mometer depends upon two characteristics of national standard for over thirty years. But platinum-first the simple relationship be- it has other advantages that find many and tween its resistance and its temperature, and increasing applications in industry. It is secondly the high purity, stability and particularly suitable where measurements are reproducibility of the specially prepared to be made over a relatively narrow range of platinum employed for this purpose.
    [Show full text]
  • Calibration Solutions for - Temperature Sensors - Infrared Thermometers - Thermocouple Referencing Systems
    2 üThe Source for Calibration Professionals Calibration Solutions for - Temperature Sensors - Infrared Thermometers - Thermocouple Referencing Systems Temperature Calibration Equipment & Services 1300°C 1200°C 1100°C Oberon R Oberon Cyclops 1000°C Pegasus Pegasus R Pegasus 900°C 800°C Medusa 700°C Gemini Jupiter Jupiter Fast-Cal ISOTower 600°C Gemini R Gemini R Medusa 500°C 400°C Quick-Cal Model 975 Model Blackbody QuickCal 300°C Drago Calisto 200°C Europa Venus Oceanus-6 Hyperion 100°C R Hyperion Model 988 Model Isis 0°C -100°C Minimum Calibration Points to Enable Coefficients to be calculated for a Platinum Resistance Thermometer IPRTs Required Points Number of Points Temp > 0°C 0°C and two positive values Rt=Ro(1 + At + Bt2) 3 Temp < 0°C 0°C, two positive values and Rt=Ro[1 + At + Bt2 + C(t-100°C) t3] 4 to > 0°C one negative value ITS-90 Required Points 0.01 – 29.76°C 0.01°C 29.76°C 2 0.01 – 156°C 0.01°C 156°C 2 0.01 – 232°C 0.01°C 156°C 232°C 3 0.01 – 419°C 0.01°C 232°C 419°C 3 0.01 – 660°C 0.01°C 232°C 419°C 660°C 4 0.01 – 962°C 0.01°C 232°C 419°C 660°C 962°C 5 -38 – 29.76°C -38°C 0.01°C 29.76°C 3 -189 – 0.01°C -189°C -38°C 0.01°C 3 Platinum Resistance Thermometer Summary Ta ble of some ITS-90 Fixed Points Identification Substance Te mp.
    [Show full text]
  • Laboratory Equipment AP
    \ \\ , f ?7-\ Watch glass 1 Crucible and cover Evaporating dish Pneumatlo trough Beaker Safety goggles Florence Wide-mouth0 Plastic wash Dropper Funnel flask collecting bottle pipet Edenmeyer Rubber stoppers bottle flask € ....... ">. ÿ ,, Glass rod with niohrome wire Scoopula (for flame re,sting) CruoiNe tongs Rubber ubing '1 ,v .... Test-tube brush square Wire gau ÿ "\ file Burner " Tripod Florence flask: glass; common sizes are 125 mL, 250 mL, 500 .d Beaker: glass or plastic; common sizes are 50 mL, mL; maybe heated; used in making and for storing solutions. 100 mL, 250 mL, 400 mL; glass beakers maybe heated. oÿ Buret: glass; common sizes are 25 mL and 50 mL; used to Forceps: metal; used to hold or pick up small objects. Funnel: glass or plastic; common size holds 12.5-cm diameter measure volumes of solutions in titrafions. Ceramic square: used under hot apparatus or glassware. filter paper. Gas burner: constructed of metal; connected to a gas supply Clamps" the following types of clamps may be fastened to with rubber tubing; used to heat chemicals (dry or in solution) support apparatus: buret/test-tube clamp, clamp holder, double buret clamp, ring clamp, 3-pronged jaw clamp. in beakers, test tubes, and crucibles. Gas collecting tube: glass; marked in mL intervals; used to 3: Clay triangle: wire frame with porcelain supports; used to o} support a crucible. measure gas volumes. Glass rod with nichrome wire: used in flame tests. Condenser: glass; used in distillation procedures. Q. Crucible and cover: porcelain; used to heat small amounts of Graduated cylinder: glass or plastic; common sizes are 10 mL, 50 mL, 100 mL; used to measure approximate volumes; must solid substances at high temperatures.
    [Show full text]
  • Experiment 1 – Separation of Copper(II) Sulfate from Sand
    Name: _________________________________ Section: _____________________ Experiment 1 – Separation of Copper(II) Sulfate from Sand Discussion Mixtures are a combination of substances in which the components keep their individual characteristics. Mixtures have variable proportions and can be separated by simple physical means. The mixture’s components have different physical properties like melting point, boiling point, or solubility that allow us to selectively remove individual components from the mixture. Once separated, the percentage of each component in the original mixture can be calculated. In this experiment, you will separate a mixture of copper(II) sulfate and sand using the physical property of solubility. You will learn about certain methods of separation that include decantation, filtration, and evaporation. Finally, the Law of Conservation of Mass will be applied to check the validity of your final calculations. Procedure 1. Weigh about 4 –5 grams of the CuSO4/sand mixture in a 100 mL beaker on the laboratory balance by taring (your instructor will explain and demonstrate). 2. Add 10–15 mL of D.I. water to the beaker, and swirl. Next, weigh and record the weight of a piece of filter paper AND an evaporating dish separately. Then assemble the filter apparatus as demonstrated by the instructor, filter the mixture, and collect the filtrate (liquid) onto the evaporating dish. Use your wash bottle (filled with D.I. water) to transfer all the undissolved solid from the beaker to the filter paper. After all the liquid has drained through the filter, wash the filter with small portions of D.I. water from the wash bottle until the washings are colorless.
    [Show full text]
  • Used for Moving Beakers Off of Hot Surfaces
    Lab Equipment and Use Review Sheet Glassware Function Glassware Function Glassware Function Running Accurately Running reactions, measuring/ reactions, heating chemicals mixing mixing delivering chemicals – chemicals, volumes of easier for mixing Beaker heating Buret liquids than beakers chemicals Erlenmeyer Flask Used in Running Used to mix vacuum reactions, chemicals to heating filtration chemicals accurately mixing determine chemicals – concentration; Volumetric easier for contains exact Florence Flask Flask Filter Flask mixing than volumes beakers Used for Used for Used for mixing filtering and accurately and heating chemicals and for adding measuring running chemicals the volume reactions– without of liquids. smaller quantities Funnel Graduated spilling Test Tube than beakers and Cylinder flasks. Holding For stirring For storing Chemicals, Glass Stirring Rod chemicals small amounts covering of chemicals Watch Glass beakers during Sample Vial heating For adding Used to small evaporate amounts of Used for Evaporating liquids chemicals – lighting burner Dish usually by Plastic Pipets drops Used to add Utility Clamp – deionized used to hold water; to add objects on a solvents for ring stand. cleaning of Iron ring – Squirt Bottle beakers and used to hold other objects above glassware. a Bunsen burner flame. Ring Stand Ring stand – Beaker Tongs with Utility used to hold Clamp and various Iron Ring objects. Equipment Function Equipment Function Equipment Function Heat source in Used to grind Used to clean the chemistry chemicals into glassware lab. Uses powder natural gas. Mortar and Pestle Test tube brush/beaker Bunsen Burner brush Used to hold a Used to Used to crucible above transport hot strongly heat a flame – used Crucible tongs crucibles and substances Clay triangle in conjunction to remove Crucible and above a flame with iron ring their covers Cover Used to hold Used to handle a Used in group of test single test tube.
    [Show full text]