InSoFast Over Existing Framed Walls Installation Guide Continuous Insulation

Existing framed walls can be insulated with either Tools and Supplies the InSoFast UX 2.0 or EX 2.5 standard panel. The • Long snap off blade utility knife instructions are the same for either panel. The pho- • Saw – hand, jig, circular, or table saw tos show the UX 2.0 panel. • 3” screws • Gap and crack foam for sealing around the Installing Panels outside edges of the fl oor and around any penetrations You can installed the panels directly over drywall or and . An alternative is to remove the drywall down to the studs as show in this guide. The old, inadequate insulation was removed and re- placed with new fi berglass insulation. To install the InSoFast panels, line up the studs of the panel with the studs of the wall.

Windows/Openings InSoFast panels can in nailed to the existing around the window opening. An alternative is to use 2”x3” lumber ripped down to the panel thickness. The InSoFast panel can then butt up to the built out framing. This provides a solid attachment for the extension jamb and window trim.

New fi berglass has been installed in the cavities.

InSoFast panels line up with the wall studs. InSoFast panels installed over existing framing.

888-501-78991 of 2 www.insofast.com Electrical Outlets There are a variety of options on the market for ex- tending the outlets to the surface of the panel.

Heat Registers Registers come in many shapes and sizes. In gener- al the register can be furred out to meet the surface of the panels.

Sealing Around Penetrations Use low expansive gaps and cracks foam to seal around openings, outlets, registers, and also in the Extended electrical box. corner of the wall.

Drywall Installation Drywall is installed over InSoFast panels in the same way as traditional wood framing. Attach drywall to the InSoFast studs using standard coarse thread all-purpose drywall screws. The InSoFast panel pro- vides solid backing for drywall around the perimeter. The ceiling drywall is locked in place when the dry- wall is applied to the walls. As with all foam insulation products, a 15 minute Heat register furred out fl ush with InSoFast panels thermal barrier, such as 1/2” drywall, is required.

Finished project. Finish register and trim.

InSoFast LLC Limits of Liability and Disclaimer of Warranty: Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for use and are in compliance with applicable laws and other government enactments. InSoFast LLC assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MER- CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. INSOFAST LLC SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. InSoFast LLC reserves the right to make any changes according to technological progress or further developments and assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. It is the responsibility of both the specifi er and the purchaser to determine if a product is suitable for its intended use.

Made in USA · US Patent No. 8,635,824 · CA Patent No. 2,761,810 · US & Foreign Patent Pending © 2017 InSoFast, LLC · All Rights Reserved