An Overview of Renewable Smart District Heating and Cooling Applications with Thermal Storage in Europe
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Consider Installing a Condensing Economizer, Energy Tips
ADVANCED MANUFACTURING OFFICE Energy Tips: STEAM Steam Tip Sheet #26A Consider Installing a Condensing Economizer Suggested Actions The key to a successful waste heat recovery project is optimizing the use of the recovered energy. By installing a condensing economizer, companies can im- ■■ Determine your boiler capacity, prove overall heat recovery and steam system efficiency by up to 10%. Many average steam production, boiler applications can benefit from this additional heat recovery, such as district combustion efficiency, stack gas heating systems, wallboard production facilities, greenhouses, food processing temperature, annual hours of plants, pulp and paper mills, textile plants, and hospitals. Condensing economiz- operation, and annual fuel ers require site-specific engineering and design, and a thorough understanding of consumption. the effect they will have on the existing steam system and water chemistry. ■■ Identify in-plant uses for heated Use this tip sheet and its companion, Considerations When Selecting a water, such as boiler makeup Condensing Economizer, to learn about these efficiency improvements. water heating, preheating, or A conventional feedwater economizer reduces steam boiler fuel requirements domestic hot water or process by transferring heat from the flue gas to the boiler feedwater. For natural gas-fired water heating requirements. boilers, the lowest temperature to which flue gas can be cooled is about 250°F ■■ Determine the thermal to prevent condensation and possible stack or stack liner corrosion. requirements that can be met The condensing economizer improves waste heat recovery by cooling the flue through installation of a gas below its dew point, which is about 135°F for products of combustion of condensing economizer. -
An Overview of the State of Microgeneration Technologies in the UK
An overview of the state of microgeneration technologies in the UK Nick Kelly Energy Systems Research Unit Mechanical Engineering University of Strathclyde Glasgow Drivers for Deployment • the UK is a signatory to the Kyoto protocol committing the country to 12.5% cuts in GHG emissions • EU 20-20-20 – reduction in EU greenhouse gas emissions of at least 20% below 1990 levels; 20% of all energy consumption to come from renewable resources; 20% reduction in primary energy use compared with projected levels, to be achieved by improving energy efficiency. • UK Climate Change Act 2008 – self-imposed target “to ensure that the net UK carbon account for the year 2050 is at least 80% lower than the 1990 baseline.” – 5-year ‘carbon budgets’ and caps, carbon trading scheme, renewable transport fuel obligation • Energy Act 2008 – enabling legislation for CCS investment, smart metering, offshore transmission, renewables obligation extended to 2037, renewable heat incentive, feed-in-tariff • Energy Act 2010 – further CCS legislation • plus more legislation in the pipeline .. Where we are in 2010 • in the UK there is very significant growth in large-scale renewable generation – 8GW of capacity in 2009 (up 18% from 2008) – Scotland 31% of electricity from renewable sources 2010 • Microgeneration lags far behind – 120,000 solar thermal installations [600 GWh production] – 25,000 PV installations [26.5 Mwe capacity] – 28 MWe capacity of CHP (<100kWe) – 14,000 SWECS installations 28.7 MWe capacity of small wind systems – 8000 GSHP systems Enabling Microgeneration -
GRID-INTERACTIVE EFFICIENT BUILDINGS TECHNICAL REPORT SERIES: Overview of Research Challenges and Gaps
Grid-interactive Efficient Buildings Technical Report Series Overview of Research Challenges and Gaps December 2019 (This page intentionally left blank) GRID-INTERACTIVE EFFICIENT BUILDINGS TECHNICAL REPORT SERIES: Overview of Research Challenges and Gaps Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency, contractor, or subcontractor thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. iii GRID-INTERACTIVE EFFICIENT BUILDINGS TECHNICAL REPORT SERIES: Overview of Research Challenges and Gaps Authors The authors of this report are: Monica Neukomm, U.S. Department of Energy (DOE) Valerie Nubbe, Navigant Consulting, Inc. Robert Fares, former American Association for the Advancement of Science (AAAS) fellow at DOE Acknowledgments The authors would like to acknowledge the valuable guidance and input provided during the preparation of this report. The authors are also grateful to the following list of contributors. Their feedback, guidance, and review proved invaluable in preparing this report. -
District Heating System, Which Is More Efficient Than
Supported by ECOHEATCOOL Work package 3 Guidelines for assessing the efficiency of district heating and district cooling systems This report is published by Euroheat & Power whose aim is to inform about district heating and cooling as efficient and environmentally benign energy solutions that make use of resources that otherwise would be wasted, delivering reliable and comfortable heating and cooling in return. The present guidelines have been developed with a view to benchmarking individual systems and enabling comparison with alternative heating/cooling options. This report is the report of Ecoheatcool Work Package 3 The project is co-financed by EU Intelligent Energy Europe Programme. The project time schedule is January 2005-December 2006. The sole responsibility for the content of this report lies with the authors. It does not necessarily reflect the opinion of the European Communities. The European Commission is not responsible for any use that may be made of the information contained therein. Up-to-date information about Euroheat & Power can be found on the internet at www.euroheat.org More information on Ecoheatcool project is available at www.ecoheatcool.org © Ecoheatcool and Euroheat & Power 2005-2006 Euroheat & Power Avenue de Tervuren 300, 1150 Brussels Belgium Tel. +32 (0)2 740 21 10 Fax. +32 (0)2 740 21 19 Produced in the European Union ECOHEATCOOL The ECOHEATCOOL project structure Target area of EU28 + EFTA3 for heating and cooling Information resources: Output: IEA EB & ES Database Heating and cooling Housing statistics -
Technical Challenges and Innovative Solutions for Integrating Solar Thermal Into District Heating
Solar Energy Systems GmbH Technical challenges and innovative solutions for integrating solar thermal into district heating P. Reiter SOLID Solar Energy Systems GmbH 06.12.2019 Solar Energy Systems GmbH Solar Heat and DH Solar Cooling Solare Process Heat 26 YEARS EXPERIENCE IN LARGE-SCALE SOLAR THERMAL 300 SYSTEMS BUILT IN MORE THAN 20 COUNTRIES OFFICES IN THE USA, SINGAPORE, GERMANY Energy used by sector: heat - mobility - electricity Solar Energy Systems GmbH Renewable Energy in Total Final Energy Consumption, by Sector, 2016; Source: REN21 Global Status Report 2019 Current supply of DH worldwide Solar Energy Systems GmbH Werner (2017), https://doi.org/10.1016/j.energy.2017.04.045 Energy mix of the future Solar Energy Systems GmbH Limited renewable electricity More wind needed to cover Seasonal current electricity demand mismatch Limited availability Recycling reduces energy from waste Industry tries Operation based on to reduce Limited electricity needs => waste heat availability does not match heat profile Differences between basic SDH and BigSolar Solar Energy Systems GmbH Basic solar district heating (SDH) for covering DHW demand Current SDH systems for covering summer DHW demand Solar Energy Systems GmbH AEVG/Fernheizwerk, Graz, AT Collector field test under real conditions! 10 collector types from 7different manufacturers: • HT-flat plate collectors (foil/double glass) Commiss Collector Nominal Solar CO2- ioning surface power yield savings • Vacuum-tube collectors area Heat • Concentrating collector 2007 8,215 m² 5.7 MW ca. 3,000 1,400 t / 2014-18 MWh/a year Differences between basic SDH and BigSolar Solar Energy Systems GmbH Solar district heating including seasonal storage (BigSolar) Scenario 2 The BigSolar concept Solar Energy Systems GmbH CITYCITY Boiler Boiler Potentials with high solar coverage ratios Solar Energy Systems GmbH SDH for DHW in summer BigSolar (incl. -
Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control
energies Article Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control Simone Buffa 1,*, Anton Soppelsa 1 , Mauro Pipiciello 1, Gregor Henze 2,3,4 and Roberto Fedrizzi 1 1 Eurac Research, Institute for Renewable Energy, Viale Druso 1, 39100 Bolzano, Italy; [email protected] (A.S.); [email protected] (M.P.); [email protected] (R.F.) 2 Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, Boulder, CO 80309-0428, USA; [email protected] 3 National Renewable Energy Laboratory, Golden, CO 80401, USA 4 Renewable and Sustainable Energy Institute, Boulder, CO 80309, USA * Correspondence: simone.buff[email protected]; Tel.: +39-0471-055636 Received: 16 July 2020; Accepted: 11 August 2020; Published: 21 August 2020 Abstract: District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. -
The Potential Air Quality Impacts from Biomass Combustion
AIR QUALITY EXPERT GROUP The Potential Air Quality Impacts from Biomass Combustion Prepared for: Department for Environment, Food and Rural Affairs; Scottish Government; Welsh Government; and Department of the Environment in Northern Ireland AIR QUALITY EXPERT GROUP The Potential Air Quality Impacts from Biomass Combustion Prepared for: Department for Environment, Food and Rural Affairs; Scottish Government; Welsh Government; and Department of the Environment in Northern Ireland This is a report from the Air Quality Expert Group to the Department for Environment, Food and Rural Affairs; Scottish Government; Welsh Government; and Department of the Environment in Northern Ireland, on the potential air quality impacts from biomass combustion. The information contained within this report represents a review of the understanding and evidence available at the time of writing. © Crown copyright 2017 Front cover image credit: left – Jamie Hamel-Smith, middle – Katie Chase, right – Tom Rickhuss on Stocksnap.io. Used under Creative Commons. United Kingdom air quality information received from the automatic monitoring sites and forecasts may be accessed via the following media: Freephone Air Pollution Information 0800 556677 Service Internet http://uk-air.defra.gov.uk PB14465 Terms of reference The Air Quality Expert Group (AQEG) is an expert committee of the Department for Environment, Food and Rural Affairs (Defra) and considers current knowledge on air pollution and provides advice on such things as the levels, sources and characteristics of air pollutants in the UK. AQEG reports to Defra’s Chief Scientific Adviser, Defra Ministers, Scottish Ministers, the Welsh Government and the Department of the Environment in Northern Ireland (the Government and devolved administrations). -
Performance Prediction of a Solar District Cooling System in Riyadh, Saudi T Arabia – a Case Study ⁎ G
Energy Conversion and Management 166 (2018) 372–384 Contents lists available at ScienceDirect Energy Conversion and Management journal homepage: www.elsevier.com/locate/enconman Performance prediction of a solar district cooling system in Riyadh, Saudi T Arabia – A case study ⁎ G. Franchini , G. Brumana, A. Perdichizzi Department of Engineering and Applied Sciences, University of Bergamo, 5 Marconi Street, Dalmine 24044, Italy ARTICLE INFO ABSTRACT Keywords: The present paper aims to evaluate the performance of a solar district cooling system in typical Middle East Solar cooling climate conditions. A centralized cooling station is supposed to distribute chilled water for a residential com- District cooling pound through a piping network. Two different solar cooling technologies are compared: two-stage lithium- Parabolic trough bromide absorption chiller (2sABS) driven by Parabolic Trough Collectors (PTCs) vs. single-stage lithium-bro- Absorption chiller mide absorption chiller (1sABS) fed by Evacuated Tube Collectors (ETCs). A computer code has been developed Thermal storage in Trnsys® (the transient simulation software developed by the University of Wisconsin) to simulate on hourly basis the annual operation of the solar cooling system, including building thermal load calculation, thermal losses in pipes and control strategy of the energy storage. A solar fraction of 70% was considered to size the solar field aperture area and the chiller capacity, within a multi-variable optimization process. An auxiliary com- pression chiller is supposed to cover the peak loads and to be used as backup unit. The two different solar cooling plants exhibit strongly different performance. For each plant configuration, the model determined the optimal size of every component leading to the primary cost minimization. -
Submission to the DCCAE's Consultation “Ireland's Draft
Submission to the DCCAE’s Consultation “Ireland’s Draft National Energy and Climate Plan (NECP) 2021-2030” Submission prepared by the Irish District Energy Association February 2019 www.districtenergy.ie [email protected] Submission to ‘Draft NECP’ Consultation from DCCAE: February 2019 Contents Contents ........................................................................................................................................................ 2 1 Introduction .......................................................................................................................................... 3 2 IrDEA welcomes the support for District Heating in the responses to the Initial NECP Consultation .. 3 3 The Potential for District Heating is much higher than proposed in the NECP .................................... 4 4 District Heating is a key enabler of Renewable Heat ............................................................................ 5 4.1 Excess Heat Should be Considered along with Renewable Heat as it also offsets carbon emitting fuels such as oil and gas ............................................................................................................................ 8 5 The Flexibility of District Heating Should be valued under Energy Security ......................................... 9 6 Increasing Renewable Heat will require stronger signals and/or support ......................................... 12 7 Bioenergy should be prioritised where it adds most value ............................................................... -
Policies and Measures on Renewable Heating and Cooling in Europe
Eionet Report - ETC/ACM 2018/17 Policies and measures on renewable heating and cooling in Europe December 2018 Authors: Tom Dauwe, Katrina Young, Magdalena Jóźwicka ETC/ACM consortium partners: National Institute for Public Health and the Environment (RIVM), Aether, Czech Hydrometeorological Institute (CHMI), Institute of Environmental Assessment and Water Research (CSIC/IDAEA), EMISIA, Institut National de l’Environnement Industriel et des Risques (INERIS), Norwegian Institute for Air Research (NILU), Öko-Institute, Öko-Recherche, Netherlands Environmental Assessment Agency (PBL), Universitat Autónoma de Barcalona 1 (UAB), Umweltbundesamt Wien (UBA-V), Vlaamse Instelling voor Technologisch Onderzoek (VITO), 4sfera Innova Cover photo © solar thermal installation Legal notice The contents of this publication do not necessarily reflect the official opinions of the European Commission or other institutions of the European Union. Neither the European Environment Agency, the European Topic Centre on Air Pollution and Climate Change Mitigation nor any person or company acting on behalf of the Agency or the Topic Centre is responsible for the use that may be made of the information contained in this report. Copyright notice © European Topic Centre on Air Pollution and Climate Change Mitigation (2018) Reproduction is authorized provided the source is acknowledged. More information on the European Union is available on the Internet (http://europa.eu). Authors Tom Dauwe: VITO/EnergyVille (BE) Katrina Young: Aether (UK) Magdalena Jóźwicka: EEA (DK) European Topic Centre on Air Pollution and Climate Change Mitigation PO Box 1 3720 BA Bilthoven The Netherlands Tel.: +31 30 274 8562 Fax: +31 30 274 4433 Web: http://acm.eionet.europa.eu Email: [email protected] Contents Executive summary ...................................................................................................................................... -
FACTSHEET 3: Introduction to Solar Thermal Heating
FACTSHEET 3: Introduction to Solar Thermal Heating Introduction The sun’s energy is free and abundant, and can be used to provide green and renewable hot water for a variety of domestic and commercial situations. For Solar Thermal Water Heating systems solar collector panels are installed on roofs facing between South West and South East (the more south facing the bet- ter the performance). These collectors absorb the sun’s energy and change it into heat, which is then used to heat water. There are two main types of col- lector plates, and several different ways these can be used to provide hot water. 1. Types of Solar Collector Plates a) Flat Plate Collectors The most common panels for solar water heating are FIGURE 1: INSTALLATION OF EVACUATED TUBES flat-plate collectors. These consist of a thin metal box (SOURCE – SOLAR FLAIR) with insulated sides and back, a glass or plastic cov- er (the glazing), and a dark coloured absorber plate. The glazing allows most of the solar energy into the 2. System Requirements box whilst preventing much of the heat gained escap- There are several necessary features that each sys- ing. The insulation on the sides and back minimizes tem must have. Systems must have freeze protection further heat loss to the surroundings. The absorber - if the water in a system freezes it can damage the plate is in the box painted with a selective dark col- solar collector, so this needs to be guarded against. oured coating, designed to maximize the amount of solar energy absorbed as heat. -
A Little About Limits…
FOREST-Handbook, chapter 03-00 1 District heating – Introduction 03-00: Introduction to small-scale district heating… As a “small” district heating network, one would consider anything with a peak thermal power less than about 5-10 MW, but there is no strict limit. The fundamental idea with district heating is simple enough, as shown by the schematic below: Thus, the system consists basically of three serial circuits, a boiler circuit, a distribution circuit and a customer circuit. In practice, there will be two customer circuits – one for the tap water and one for the comfort heating system water. These will be manifest as two separate coils in the customer heat exchanger but for simplicity only one is included in the schematic. The main components and their roles The boiler-end heat exchanger Looking at the schematic above it is obvious that the district heating system contains two heat exchangers – one at the boiler end and one with the customer. From a purely theoretical point of view, it might seem wise to exclude the boiler-end heat exchanger and to use the boiler circuit water also for the distribution, but this is not recommended for two reasons: 1) The part in the system most exposed to and most vulnerable to leakages is the distribution network, which may well extent for several kilometres across the township. In case of a major leakage – and if the boiler water is also the circulating water – the boiler will be dry and may suffer severe damage. Hence, the heat exchanger protects the boiler. 2) For maximum efficiency in the system as a whole it is important that the return water in the distribution system is as cold as possible – preferably below 50 oC.