B9512G Control Panels B9512G Control Panels
Total Page:16
File Type:pdf, Size:1020Kb
Intrusion Alarm Systems | B9512G Control Panels B9512G Control Panels www.boschsecurity.com u Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three u Provides up to 599 points using a combination of hardwired or wireless devices for installation flexibility, and up to 32 areas and 32 doors for up to 2,000 users u On-board Ethernet port for Conettix IP alarm communication and remote programming, compatible with modern IP networks including IPv6/ IPv4, Auto-IP, and Universal Plug and Play u Installer-friendly features for simple installation and communications, including plug-in PSTN and cellular communication modules u Remote Security Control app which allows users to control their security systems - and view system cameras - remotely from mobile devices such as phones and tablets The B9512G Control Panel and the B8512G Control • Monitor alarm points for intruder, gas, or fire alarms. Panel are the new premier commercial control panels • Program all system functions local or remote using from Bosch. B9512G control panels integrate Remote Programming Software (RPS) or the Installer intrusion, fire, and access control providing one simple Services Portal programming tool (available in user interface for all systems. Europe, Middle East, Africa, and China) or by using With the ability to adapt to large and small basic programming through the keypad. applications, the B9512G provides up to 599 • Add up to 32 doors of access control using the optional B901 Access Control Module. Optionally use individually identified points that can be split into 32 the D9210C Access Control Interface Module for up areas. to eight of the 32 doors. The control panel can communicate through its built-in The B9512G is a direct replacement for previous Ethernet port (not applicable to “E” control panels), or control panel models D9412GV4, D9412GV3, through compatible plug-in modules that can send D9412GV2, and D9412G. events over the public switched telephone network (PSTN) or over cellular network communications. Functions For users, programmable keypad shortcuts, situation sensitive on-screen help, and a bilingual user interface Programmable outputs make system operation simple and easy. • Four alarm-output patterns • Programmable bell test With the B9512G Control Panel, you can: 2 | B9512G Control Panels Point response rearmed, and are disarmed for no longer than a • Selectable point response time specific, configurable, amount of time (for example, • Selectable EOL values and configuration service time). • Cross point capability • Fire alarm verification Custom functions • Dangerous gas indicator includes carbon monoxide For added convenience, the installer can program (NFPA 720) custom functions that allow customers to complete • Watch mode complex tasks with one simple action. For example, a • 63 point profiles custom function can bypass a group of points and arm the system, allowing the user to perform these User interface • Supervision of up to 32 keypads functions with one easy command. Users can activate • Custom keypad text is fully programmable through custom functions with a keypad, keyfob, token, or RPS or the Installer Services Portal programming tool card, or the control panel can activate a function in (available in Europe, Middle East, Africa, and China) reaction to a faulted point, or automatically through a • Full function menu including customizable shortcuts scheduled event (SKED). • Authority by area and 32 character name for each Passcode security user • Two-man rule. Requires two people with two unique • 14 custom authority levels to restrict system features passcodes to be present at the time of opening. that each user can access • Early ambush. Allows users to verify that the facility is • Programmable primary and secondary language by safe by requiring two passcodes. The control panel user and keypad sends a duress event if the user does not enter the • 12 available languages (any two can be concurrently passcode a second time after inspecting the used) premises. User interface languages • Dual authentication. Requires two forms of The following table shows the available languages per identification before processing certain system keypad type. commands, including turning off the system and opening doors. A standard system user must have a B915/ B920 B921C B930 B940 passcode, a credential (token or card), and B915I W/ appropriate command authority permissions. B942/ B942 Door control W Using the B901 Access Control Module or D9210C English ✔ ✔ ✔ ✔ ✔ Access Control Interface Module, the control panel provides a fully supervised access control solution. Chinese ✔ ✔ The solution offers 14 programmable levels of access authority. Authority for door access is controlled by Dutch ✔ ✔ ✔ ✔ ✔ the user level, the group of the user, the time of day, French ✔ ✔ ✔ ✔ ✔ the door state, and the area armed (On/Off) state. German ✔ ✔ ✔ ✔ ✔ Easy exit control The control panel changes from one On (armed) state Greek ✔ ✔ to another without turning off (disarming) the system. For example, if you change the state from Part On Hungarian ✔ ✔ ✔ ✔ ✔ (Perimeter Arm) to All On (Master Arm), the control Italian ✔ ✔ ✔ ✔ ✔ panel complies and reports the change. Easy exit control reduces the number of keystrokes, simplifying ✔ ✔ Polish system operation. Portuguese ✔ ✔ ✔ ✔ ✔ Programmable passcode-controlled menu list Passcode-controlled shortcuts provide users only with Spanish ✔ ✔ ✔ ✔ ✔ the options and information pertinent to them, Swedish ✔ ✔ ✔ ✔ ✔ simplifying system operation. Flexible control Area configurations The system provides the flexibility to choose added Link multiple areas to a shared area such as a lobby or convenience or high security. For example, you can common entryway. The shared area then automatically restrict to a keypad's immediate local area turning on turns On (arms) when all associate areas are armed (arming) and turning off (disarming) the system with a and turns Off (disarms) when any one associate area passcode, even if the user has access to other areas. is disarmed. For higher security applications, the Area This is particularly useful for high security areas, Re-Arm feature guarantees that areas are always 3 | B9512G Control Panels where a user may have access to the area, but would prefer to only turn off (disarm) the area individually Notice rather than with the rest of the system. For premises equipment used in the communication path, such as routers, use only UL Monitor Delay/Delayed Response listed equipment. Create a special point profile that delays the reaction of a point for a specified time (up to 1 hour in minutes IP communication and seconds). This delay provides time for the The control panel can use IP to communicate with a specified condition to reset before activating any Conettix D6600 or a Conettix D6100IPv6 annunciation. The system can annunciate locally and communications receiver/gateway. Use one of the send a report, if desired. When the system is armed, following for IP: the point can respond like a normal point - providing • The on-board Ethernet connection (not applicable to dual functionality. Use this feature to ensure that “E” control panels) perimeter doors have not been propped open, or to • Ethernet Communication Module: B426 monitor critical areas such as computer rooms and • Plug-in cellular communicator: B440/B441/B442/ safes, for example. B443/B444/B444-A/B444-V Conettix IP communication provides a secure path that System users includes anti-replay/anti-substitution features, and The system supports up to 2,000 users. Each user can enhanced security with up to AES 256-bit encryption have a personalized passcode, a wireless keyfob, and (using Cipher Block Chaining (CBC)). an access credential to control the system. You can The control panel supports Domain Name System assign passcodes to one of 14 customized authority (DNS) for both remote programming and central levels in each area that can be restricted to operate station communication. DNS provides ease of use, only during certain times. You can program a primary eliminating the need to use static IP addresses as your and secondary language for each user and by keypad reporting destination, and accommodates a simple (select from English, Chinese, French, Greek, solution for central station disaster recovery. The Hungarian, Italian, Polish, Portuguese, and Spanish). control panel supports both IPv6 and IPv4 networks. The keypad changes to the user’s programmed language when the user enters his passcode or holds Communication paths the Help key. The control panel accommodates up to four separate phone and four separate network paths to the central Route groups and destinations station receiver. When resetting alarms or turning a The control panel can send reports to four different system on and off, the user is identified by name and route groups using one primary and up to three number. backup destination devices for each route group. Personal notification Reporting capabilities The control panel can send text messages and emails The control panel has flexible communications for for personal notification over Ethernet or using a most central station receivers with reporting cellular communicator. You can configure up to 32 capabilities such as: • Individual point numbers destinations using a combination of cellular phone • Opening or closing reports by user and area number numbers and email addresses. The control panel sends • Remote programming attempts notifications in the