ARIES Netlink™ Multi-Loop Intelligent Fire Alarm-Suppression Control Unit Effective: March 2017 K-76-800

Total Page:16

File Type:pdf, Size:1020Kb

ARIES Netlink™ Multi-Loop Intelligent Fire Alarm-Suppression Control Unit Effective: March 2017 K-76-800 ARIES NETLink™ Multi-Loop Intelligent Fire Alarm-Suppression Control Unit Effective: March 2017 K-76-800 FEATURES • Intelligent addressable multi-loop, suppression-focused control unit • Triple R redundancy provides maximum protection against inadvertent release • Out-of-the-box features: - 2 SLCs with 255 unrestricted addresses each (510 total) - 4 x 40 Display-Keypad - 4 Programmable soft-switches - 2 NACs and 2 R-NACs - 3 Programmable and 1 Trouble Form-C Relays - 2 Auxiliary Power Outputs, 2 amps each - USB ports for PC and printer - RS-232 ports for graphics - 120/240V, 50/60 Hz AC input - 5.4 A Power Supply Unit - Charging Capacity of 165 AH DESCRIPTION - CONTROL UNIT - RS-485 Annunciator bus The ARIES NETLink™ is one of the most technologically - 2-Tier or 3-Tier NEMA 1 Enclosure – fits between 16”studs advanced intelligent fire alarm suppression-focused con- • Suppression systems include: trol units available to the industry today. It combines the - FM-200, FE-13, 3M Novec 1230 Fire Protection Fluid, high quality, system reliability, and flexibility required by mod- Carbon Dioxide, Argonite & Halon Clean Agents ern commercial, high-tech and industrial applications in an - Dry Chemical, Wet Chemical aesthetically-pleasing and physically-robust package. Its - Water-Mist - Sprinkler Supervisory Service modular architecture enables easy field expansion from the - Deluge, Pre-Action, Foam, Foam-Water Systems base 2-SLC unit that supports 510 addressable devices (255 • Modular and expandable per circuit) to an 8-SLC system that supports 2,040 address- - From 3 to 8 SLCs (2,040 addresses) able devices; 130,560 addresses available for a 64-node net- - Up to 96 relays work. - Up to 72 release/NAC circuits The ARIES NETLink is compact, fits between wall stud - Combinations of the above and/or functional modules dimensions, and is designed to be quick and easy to • Networkable up to 64 nodes (130,560 addresses) install. Cutting edge technologies incorporated in the elec- • Flexible programming • High level serviceability and diagnostics tronics design enable diagnostics for time-efficient com- - Ground fault detection by circuit missioning. - 10,000 event log capacity Main Controller Board - MCB - Internet connectivity with e-mail notification feature The ARIES NETLink’s main printed circuit board contains • Modbus RTU, Modbus TCP/IP, BACnet MS/TP and BACnet the system’s central processing unit (CPU) and all of the IP compatibility • Backwards compatible with installed investment primary circuits. The MCB is the heart of the system, con- - SmartOne SLC devices & protocol trolling the operation and supervision of all the system - Kidde Control Heads modules and software. It receives loop device data, pro- -Actuators cesses the data based on pre-programmed instructions, - Legacy PEGAsys panels via simple retrofit kit and transmits output commands to the output modules, • Seamlessly integrated HSSD, ASD and LHD field devices, and display(s). The MCB is mounted to the • Pluggable terminal blocks enclosure using special design hinged standoffs which • User Interface 4 x 40 display supports 4 languages: permit the board to swing left and enable easy access to English, French Canadian, Spanish and Portuguese the PMU/PSU assembly behind. • French Canadian, Spanish and Portuguese Language kit • Approvals/Listings*: User Interface - FM Approved to ANSI/UL864 The user interface consists of a built-in keypad and display - UL Listed No. S2422 which provide physical means by which an operator and/or - cUL Listed No. S2422 installer performs system functions, enters the security - CSFM Approved: No. 7165-1076:0195 password, operates soft keys, navigates the system - California OSHPD Special Seismic Certification Pre- menus, configures and tests the entire ARIES NETLink Approval, No. OSP-0286-10 system. The LCD display supports four languages: English, - NYC Fire Department Certificate of Approval: No. 6092 - City of Chicago Acceptable for Class 1 Applications French, Spanish, and Portuguese (selected from the top- • RoHS compliant level menu). SmartOne Signaling Line Circuit (SLC)-255 devices per circuit (No restrictions on Device Type) 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 B A (-) (+) + - + (-) (-) (+) (+) B A + - + (-) (-) (+) (+) (-) (+) AlarmLin e B A + - + (-) (-) (+) (+) (-) (+) LED LED SW SW CP CPC PC PC PC CP CPC PC PC PC LED LED SW SW CP CPC PC PC PC LED LED SW SW SmartOne APIC TM TM TM 8 7 6 5 4 3 2 1 B A (-) (+) + - + (-) (-) (+) (+) Sm ar tOne Sm ar tOne MODE L A I, N/O MODE L A I, N/O LED LED SW SW 06-235578-001 PC PC PC PC INSTRUCTIONS 06-235578-001 INSTRUCTIONS Sm ar tOne SmartOne MODE L A I, N/O 06-235578-001 INSTRUCTIONS KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 FOR SERVICE SEND TO: DATE OF MANUFACTURE: A.NO.CAT. 70-407008-001 SEE INSTALLATION FOR SERVICE SEND TO: DATE OF MANUFACTURE: A.NO.CAT. 70-407008-001 SEE INSTALLATION MAX. INSTALL. TEMP. 120°F MAX. INSTALL. TEMP. 120°F ALL TERMINALS ARE POWER LIMITED ALL TERMINALS ARE POWER LIMITE D CAT. NO. 70- 407008-SEE INSTALLATION 001 FOR SERVICE SEND TO: DATE OF MANUFACTURE: MAX . INSTALL. TE MP. 120° F ALL TERMINALS ARE POWER LIMITED TM Sm ar tOne MODE L A I, N/O 06-235578-001 INSTRUCTIONS KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 CAT. NO. 70-407008-001 SEE INSTALLATION FOR SERVICE SEND TO: DATE OF MANUFACTURE: MAX. INSTALL. TEMP. 120°F ION PHOTO THERMAL ALL TERMINALS ARE POWER LIMITED (CPD-7052) (PSD-7152) (THD-7252) SUPPRES SION SYSTEM ABOR T PUSH PULL Abort LHS AlarmLine DAF Station ORION XT Manual AIR-Intelligence High Sensitivity Release Air Sampling Smoke Detection Remote Display Detection Control Modules (RDCMs),1-15 Remote Releasing - HVAC R 7 6 5 3 2 1 A E 4 + - + (-) (-) (+) (+) N/C N/O Module COM - Shutdowns G L PC PC PC PC E E N A : TM 1 ADDRESSABLE RELEASE MODULE T S E 120°F TEMP. 7 ARE POWER LIMITED - Doors and Dampers RVICE SENDRVICE TO: MODEL AO SmartOne 06-235577-001 INSTRUCTIONS KIDDE-FENWAL, INC. KIDDE-FENWAL, 400 MAIN ST. ASHLAND, MA 0172 CAT. NO. 70-408004-001 CAT. SEE INSTALLATION FOR SE DATE OF MANUFACTURE DATE MAX. INSTALL. TERMINALS 5- TERMINALS 1-4 ARE POWER LIMITED - Elevator Recall LED Annunciator ASM Horns/ Relay Modules (LAMs), Suppression Release Strobes Module 1-16 Release Additional SLCs Relay Outputs Internet Communications Module (ICM) BACnet/Modbus USB and/or Serial Connection for Laptop and Printer Interface Backplane ARIES NETLink Control Panel Card Cage 1 2 3 4 5 6 1 Signal Line Circuit (SLC) Card 2 Network Interface Card (NIC) 3 Relay Card 4 City Tie Card 5 Release/Notification Appliance Circuit (R-NAC) Card 6 Digital Alarm Communicator Transmitter (DACT) Figure 1. Modular Design to Meet the Most Demanding Applications - 2 - MAIN CONTROLLER BOARD SPECIFICATION (Continued) User Interface Maximum Output Current: Non-Synchronized: 2.0 A Synchronized: 1.5 A Maximum Output Circuit 28 VDC Terminal Voltage: Minimum Output Circuit 20 VDC Terminal Voltage: End-of-Line Resistor: 10 K, 5%, 1/2 W Maximum Allowable Voltage 2 V at End-of-Line Drop: MCB Release/Notification Appliance Circuits Number of Circuits: Two Individually Configurable for Notification or Release: Yes Notification Specifications: Same as NAC Release Specifications: Main Controller Board (MCB) Compatible devices: • Kidde Control head: max 1 Figure 2. Main Controller Board and User Interface • Water Mist Solenoid valve: max 1 • FM Group A, B, D, E, F, G, MAIN CONTROLLER BOARD SPECIFICATION I, J or K Solenoid: max 1 • Metron actuator: -P/N 83-132500-500 max 1 MCB Signaling Line Circuits -P/N 83-131082-001 max 1 Number of Circuits: Two Device type configurable: Yes, with device on- Device Capacity: 255 devices per SLC time after activation Device Type Restriction: None Wiring Classes: Wiring Classes: Class A, B or X • Solenoids: Class A or B T-Tapping Allowed: Class B only •Actuators: Class B Circuit Voltage: Nominal 24 VDC Power Limited: Yes, requires In-Line Maximum Line Resistance: 40 ohms per loop diode device Maximum Capacitance: 0.5 µF Maximum Output Circuit Terminal Voltage: 28 VDC Maximum Current: 350 mA (short circuit) End-of-Line Resistor: 10 K, 5%, 1/2 W Wiring Specifications: Twisted #14AWG - #18AWG, unshielded, Allowable Voltage Drop: 2 V low-capacitance wire with a nominal wire-to- MCB Relays wire capacitance of Number and type: 3 Programmable and approximately 20 pf. 1 Trouble Relay Relay Form: Form-C (1 NO + 1 NC) MCB Notification Appliance Circuits Rating: 3A @ 30 VDC/120 VAC Number of Circuits: Two Compatible devices: 24 VDC polarized horns, strobes, bells, etc. Wiring Classes: Class A or B Power Limited: Yes Synchronized Strobes: Yes, configurable - 3 - MAIN CONTROLLER BOARD SPECIFICATION (Continued) POWER SUPPLY & MANAGEMENT SPECIFICATION MCB RS-232 Serial Ports Number of PMUs per Minimum: 1 Number of Ports: 2 control unit Maximum: 4 Specifications: Bi-Directional 9600 Number of PSUs per PMU Minimum: 1 Baud, 8 Data Bits, 1 Maximum: 2 Stop Bit, No Parity Primary AC Input Power: • 1 PSU: 120 VAC, 50/60 Hz, MCB RS-485 Annunciator Port 3.2 A Number of Ports: 1 240 VAC, 50/60 Hz, 1.6 A Compatible Devices: •RDCM Max. 15 devices • 2 PSU: 120 VAC, 50/60 Hz, •R-LAM Max. 16 devices 6.4 A •ATM-L Max. 16 devices 240 VAC, 50/60 Hz, •ATM-R Max. 16 devices 3.2 A Compatible Device 31 in any order Allowable Input Voltage 115 + 5% VAC Maximum: Variation: 230 + 4% VAC Wiring Type: Twisted, shielded, low- Secondary DC Output: capacitance fire alarm • 1 PSU: 5.4 A @ 27.6 VDC wire • 2 PSU: 10.8 A @ 27.6 VDC Wiring Minimum Size: AWG 18 Voltage Selection: Slide switch on PSU Maximum wire length: 4,000 ft.
Recommended publications
  • Distributed Programming I (Socket - Nov'09)
    Distributed programming I (socket - nov'09) Warning for programmers network programming is dangerously close to O.S. Network programming: sockets kernel, and therefore: It can easily hang the O.S. verify the results of every operation, without assuming anything as granted Antonio Lioy < [email protected] > APIs can vary in details that are minimal but important consider every possible situation to create english version created and modified by “portable” programs Marco D. Aime < [email protected] > we will try to use Posix 1.g Politecnico di Torino Dip. Automatica e Informatica ISO/OSI, TCP/IP, network programming Exercise – copying data copy the content of file F1 (first parameter on the application command line) into file F2 (second parameter on the 7. application details application command line) user 6. presentation (l6: XDR/XML/... process l5: RPC/SOAP/...) 5. session network programming 4. transport TCP UDP SCTP interface 3. network IPv4, IPv6 kernel communication 2. data link device driver details 1. physical and hardware OSI model IP suite ref. UNP Intro copyfile.c Error messages Error functions must contain at least: best to define standard error reporting functions [ PROG ] program name which accept: [ LEVEL ] error level (info, warning, error, bug) a format string for the error [ TEXT ] error signalling, the most specific as possible a list of parameters to be printed (e.g. input file name and line where the problem has UNP, appendix D.4 (D.3 in 3rd edition) occurred) errno? termination? log level [ ERRNO ] system error number and/or name (if applicable) err_msg no no LOG_INFO err_quit no exit(1) LOG_ERR suggested format: err_ret yes no LOG_INFO err_sys yes exit(1) LOG_ERR ( PROG ) LEVEL - TEXT : ERRNO err_dump yes abort( ) LOG_ERR errlib.h errlib.c © A.Lioy - Politecnico di Torino (2009) B-1 Distributed programming I (socket - nov'09) stdarg.h stdarg.h usage example variable list of arguments (ANSI C) create a function named my_printf declared with an ellipsis (.
    [Show full text]
  • Beej's Guide to Unix IPC
    Beej's Guide to Unix IPC Brian “Beej Jorgensen” Hall [email protected] Version 1.1.3 December 1, 2015 Copyright © 2015 Brian “Beej Jorgensen” Hall This guide is written in XML using the vim editor on a Slackware Linux box loaded with GNU tools. The cover “art” and diagrams are produced with Inkscape. The XML is converted into HTML and XSL-FO by custom Python scripts. The XSL-FO output is then munged by Apache FOP to produce PDF documents, using Liberation fonts. The toolchain is composed of 100% Free and Open Source Software. Unless otherwise mutually agreed by the parties in writing, the author offers the work as-is and makes no representations or warranties of any kind concerning the work, express, implied, statutory or otherwise, including, without limitation, warranties of title, merchantibility, fitness for a particular purpose, noninfringement, or the absence of latent or other defects, accuracy, or the presence of absence of errors, whether or not discoverable. Except to the extent required by applicable law, in no event will the author be liable to you on any legal theory for any special, incidental, consequential, punitive or exemplary damages arising out of the use of the work, even if the author has been advised of the possibility of such damages. This document is freely distributable under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 License. See the Copyright and Distribution section for details. Copyright © 2015 Brian “Beej Jorgensen” Hall Contents 1. Intro................................................................................................................................................................1 1.1. Audience 1 1.2. Platform and Compiler 1 1.3.
    [Show full text]
  • POSIX Signals
    CSE 410: Systems Programming POSIX Signals Ethan Blanton Department of Computer Science and Engineering University at Buffalo Introduction Signals Blocking Concurrency Sending Signals Summary References POSIX Signals POSIX signals are another form of interprocess communication. They are also a way to create concurrency in programs. For these two reasons, they are rather complicated and subtle! Signals provide a simple message passing mechanism. © 2018 Ethan Blanton / CSE 410: Systems Programming Introduction Signals Blocking Concurrency Sending Signals Summary References Signals as Messages POSIX signals are asynchronous messages. Asynchronous means that their reception can occur at any time.1 The message is the reception of the signal itself. Each signal has a number, which is a small integer. POSIX signals carry no other data. 1Almost. We’ll see how to control it later. © 2018 Ethan Blanton / CSE 410: Systems Programming Introduction Signals Blocking Concurrency Sending Signals Summary References Signal Types There are two basic types of POSIX signals: Reliable signals Real-time signals Real-time signals are much more complicated. In particular, they can carry data. We will discuss only reliable signals in this lecture. © 2018 Ethan Blanton / CSE 410: Systems Programming Introduction Signals Blocking Concurrency Sending Signals Summary References Asynchronous Reception From the point of view of the application: Signals can be blocked or ignored Enabled signals may be received between any two processor instructions A received signal can run a user-defined function called a signal handler This means that enabled signals and program code must very carefully manipulate shared or global data! © 2018 Ethan Blanton / CSE 410: Systems Programming Introduction Signals Blocking Concurrency Sending Signals Summary References Signals POSIX defines a number of signals by name and number.
    [Show full text]
  • Programming with POSIX Threads II
    Programming with POSIX Threads II CS 167 IV–1 Copyright © 2008 Thomas W. Doeppner. All rights reserved. Global Variables int IOfunc( ) { extern int errno; ... if (write(fd, buffer, size) == –1) { if (errno == EIO) fprintf(stderr, "IO problems ...\n"); ... return(0); } ... } CS 167 IV–2 Copyright © 2008 Thomas W. Doeppner. All rights reserved. Unix was not designed with multithreaded programming in mind. A good example of the implications of this is the manner in which error codes for failed system calls are made available to a program: if a system call fails, it returns –1 and the error code is stored in the global variable errno. Though this is not all that bad for single-threaded programs, it is plain wrong for multithreaded programs. Coping • Fix Unix’s C/system-call interface • Make errno refer to a different location in each thread – e.g. #define errno __errno(thread_ID) CS 167 IV–3 Copyright © 2008 Thomas W. Doeppner. All rights reserved. The ideal way to solve the “errno problem” would be to redesign the C/system-call interface: system calls should return only an error code. Anything else to be returned should be returned via result parameters. (This is how things are done in Windows NT.) Unfortunately, this is not possible (it would break pretty much every Unix program in existence). So we are stuck with errno. What can we do to make errno coexist with multithreaded programming? What would help would be to arrange, somehow, that each thread has its own private copy of errno. I.e., whenever a thread refers to errno, it refers to a different location from any other thread when it refers to errno.
    [Show full text]
  • UNIT: 4 DISTRIBUTED COMPUTING Introduction to Distributed Programming
    UNIT: 4 DISTRIBUTED COMPUTING Introduction To Distributed Programming: • Distributed computing is a model in which components of a software system are shared among multiple computers. Even though the components are spread out across multiple computers, they are run as one system. This is done in order to improve efficiency and performance. • Distributed computing allows different users or computers to share information. Distributed computing can allow an application on one machine to leverage processing power, memory, or storage on another machine. Some applications, such as word processing, might not benefit from distribution at all. • In parallel computing, all processors may have access to a shared memory to exchange information between processors. In distributed computing, each processor has its own private memory (distributed memory). Information is exchanged by passing messages between the processors. • Distributed computing systems are omnipresent in today’s world. The rapid progress in the semiconductor and networking infrastructures have blurred the differentiation between parallel and distributed computing systems and made distributed computing a workable alternative to high- performance parallel architectures. • However attractive distributed computing may be, developing software for such systems is hardly a trivial task. Many different models and technologies have been proposed by academia and industry for developing robust distributed software systems. • Despite a large number of such systems, one fact is clear that the software
    [Show full text]
  • Introduction to POSIX Signals
    Introduction to POSIX Signals Michael Jantz Prasad Kulkarni Douglas Niehaus Introduction ● This lab is an introduction to signals in Unix systems. – In it, you will learn about some common uses for signals. – You will also construct a small program that uses signals. ● Unpack the starter code, then make and tag it: – bash> tar zxvf eecs678-signals-lab.tar.gz – cd signals/; make; ctags -R EECS 678 Signals Lab 2 Signals ● A signal is a short message that may be sent to a process or a group of processes. ● The only information given to a process is usually the number identifying the signal; there is no room in standard signals for arguments, a message or other accompanying information. ● Signals serve two main purposes: – To make a process aware that a specific event has occurred. – To cause a process to execute a signal handler function included in its code. EECS 678 Signals Lab 3 Interrupts vs. Signals ● Signals and interrupts are very similar in their behavior ● Important difference: interrupts are sent to the operating system by the hardware, signals are sent to the process by the operating system, or other processes through the OS ● Important similarity: both signals and interrupts associate handlers with asynchronous events which interrupt current processing, thus inserting the handler into current code path ● Signals can thus be thought of as an interrupt in software: – However, note that signals have nothing to do with Soft-IRQs. The name seems related, but these are a method for deferring much of the processing associated with a hardware-interrupt into a less restrictive execution context inside the OS.
    [Show full text]
  • POSIX Signal Handling in Java
    Technical Document Series POSIX Signal Handling in Java POSIX Signal Handling In Java Introduction POSIX signals inform a running process of external events, such as the user wishing to kill the process, or the operating system signaling an impending shutdown, or the process being suspended or reinstated; or the process may have violated a resource constraint, such as excessive CPU usage or attempts to access areas outside its permitted memory space, and is asked to shutdown. In short, POSIX signals serve many different purposes. Some are even up to interpretation, such as the HUP (HangUP) signal, which is commonly used to inform a process that something about its environment has changed and the process should adjust accordingly. Some programs may interpret this to mean that the configuration has changed and needs to be reloaded; or the log file has been moved for archiving purposes and a new one should be started. The use of signals is widespread, especially on Unix-based operating systems, but Java provides no standard interface for a Java application to hear and react to them. This document shows you how to get around this limitation. The Good, the Bad, and the Ugly The good news is that there is a way to intercept POSIX signals and react to them in Java. This would allow your Java program to avoid being killable with ^C (SIGINT), for example, even ignore termination requests from the operating system (SIGTERM). Neither of these is necessarily a good idea, of course, unless you know exactly why you would want to catch these signals and either handle them yourself or ignore them altogether.
    [Show full text]
  • Lecture 14: Paging
    Lecture 14: Paging Fall 2018 Jason Tang Slides based upon Operating System Concept slides, http://codex.cs.yale.edu/avi/os-book/OS9/slide-dir/index.html Copyright Silberschatz, Galvin, and Gagne, 2013 "1 Topics • Memory Mappings! • Page Table! • Translation Lookaside Bu$ers! • Page Protection "2 Memory Mapped • Logical address translated not to memory but some other location! • Memory-mapped I/O (MMIO): hardware redirects read/write of certain addresses to physical device! • For example, on x86, address 0x3F8 usually mapped to first serial port! • Memory-mapped file (mmap): OS redirects read/write of mapped memory region to file on disk! • Every call to read() / write() involves a system call! • Writing to a pointer faster, and OS can translate in the background (also see upcoming lecture) "3 Memory-Mapped File • In Linux, typical pattern is to:! • Open file, using open() function! • Optional: preallocate file size, using ftruncate()! • Create memory mapping, using mmap() function! • Do work, and then release mapping using munmap() function! • Kernel might not write data to disk until munmap() "4 mmap() function void *mmap(void *addr, size_t length, int prot, int flags, int fd, off_t offset) • addr is target address of mapping, or NULL to let kernel decide! • length is number of bytes to map! • prot defines what mapping protection (read-only or read/write)! • flags sets other options! • fd is file descriptor that was returned by open()! • offset is o$set into file specified by fd "5 mmap() example part 1 • See man page for each of these functions
    [Show full text]
  • Interprocess Communication 1 Processes • Basic Concept to Build
    Interprocess Communication 1 Processes • Basic concept to build the OS, from old IBM mainframe OS to the most modern Windows • Used to express the requirements to be met by an OS – Interleave the execution of multiple processes, to maximize CPU utilization while providing good response time – Allocate resources to processes using a policy while avoiding deadlocks – Support interprocess communications and user creation of processes to help structuring applications • Background – Computer platform * Collection of hardware resources – CPU, memory, I/O modules, timers, storage devices – Computer applications * Developed to perform some task * Input, processing, output – Efficient to write applications for a given CPU * Common routines to access computer resources across platforms * CPU provides only limited support for multiprogramming; software manages sharing of CPU and other re- sources by multiple applications concurrently * Data and resources for multiple concurrent applications must be protected from other applications • Process – Abstraction of a running program – Unit of work in the system – Split into two abstractions in modern OS * Resource ownership (traditional process view) * Stream of instruction execution (thread) – Pseudoparallelism, or interleaved instructions – A process is traced by listing the sequence of instructions that execute for that process • Modeling sequential process/task – Program during execution – Program code – Current activity – Process stack * Function parameters * Return addresses * Temporary variables –
    [Show full text]
  • Dressing up Data For
    Dressing up data for Hannes Mühleisen DSC 2017 Problem? • People push large amounts of data into R • Databases, Parquet/Feather … • Need native SEXP for compatibility • R has no abstraction for data access • INTEGER(A)[i] * INTEGER(B)[j] etc. • Data possibly never actually used 2 Sometimes lucky • Perfectly compatible bits: • int my_int_arr[100]; • double my_dbl_arr[100]; • Doctor SEXP header in front of data and good to go • Implemented in MonetDBLite with custom allocator • Next version on CRAN will have this https://github.com/hannesmuehleisen/MonetDBLite 3 Zero-Copy in MonetDBLite Page 1 Page 2 Page 3 Page 4 Page 5 addr = mmap(col_file, len, NULL) col_file addr addr1 = mmap(NULL, len + PAGE_SIZE, NULL) addr2 = mmap(col_file, len, addr1 + 4096) addr3 = addr1 + PAGE_SIZE - sizeof(SEXPREC_ALIGN) SEXP res = allocVector3(INTSXP, len/sizeof(int), &allocator); Page 0 Page 1 Page 2 Page 3 Page 4 Page 5 col_file addr1 res & addr3 4 Demo 1 Stock R, MonetDBLite & zero-copy library(“DBI”) con <- dbConnect(MonetDBLite::MonetDBLite(), "/tmp/dscdemo") dbGetQuery(con, "SELECT COUNT(*) FROM onebillion”) # 1 1e+09 system.time(a <- dbGetQuery(con, "SELECT i FROM onebillion”)) # user system elapsed # 0.032 0.000 0.033 .Internal(inspect(a$i)) # @20126efd8 13 INTSXP g0c6 [NAM(2)] (len=1000000000, tl=0) 1,2,3,4,5,... Native R Vector w. zero-copy! 5 Not always so lucky • What if we have to actually convert? • Strings, TIMESTAMP to POSIXct etc. • NULL/NA mismatches • More involved data representations • compressed, batched, hybrid row/col, … • Need to convert all data before handing control over to R. • Can take forever, takes memory, non-obvious wait time 6 ALTREP • Luke Tierney, Gabe Becker & Tomas Kalibera • Abstract vectors, ELT()/GET_REGION() methods • Lazy conversion! static void monetdb_altrep_init_int(DllInfo *dll) { R_altrep_class_t cls = R_make_altinteger_class(/* .
    [Show full text]
  • Signals and Pipes
    Signals and Pipes Signals and Pipes 1/20 Learning Objectives Signals and Pipes I Understand synchronization issues with respect to signals I Learn about the client-server model using pipes and named pipes I Understand basic concepts of servers and daemons 2/20 More on Signals Signals and Pipes I Two main system calls that deal with signals: signal() and sigaction(). The sigaction() call is consistent across various systems whereas signal() is not necessarily consistent across systems but is simpler to use. See man page for details on both. I Examples: I signal-ex1.c I signal-ex2.c 3/20 Signal Handling after Exec Signals and When a program is exec’d the status of all signals is either default or Pipes ignore. The exec functions changes the disposition of any signals that are being caught to their default action (why?) and leaves the status of all other signals alone. For example: if (fork()==0) {// the child process if(signal(SIGINT, SIG_IGN) == SIG_ERR) err_ret ("failed␣to␣set␣SIGINT␣behavior"); if(signal(SIGTSTP, SIG_IGN) == SIG_ERR) err_ret ("failed␣to␣set␣SIGTSTP␣behavior"); execvp(program, argv); // the exec 'd program will ignore the // signalsSIGINT andSIGTSTP 4/20 Signal Handling for an Application Signals and How an application ought to set its signal handling: Pipes An application process should catch the signal only if the signal is not currently being ignored. int sig_int(), sig_quit(); if(signal(SIGINT, SIG_IGN) != SIG_IGN) signal(SIGINT, sig_int); if(signal(SIGQUIT, SIG_IGN) != SIG_IGN) signal(SIGQUIT, sig_quit); See code example: signal-ex3.c 5/20 Other Signal Issues Signals and Pipes I Signals are set to their default after being caught (under Linux and System V UNIX semantics).
    [Show full text]
  • 6.828: Virtual Memory for User Programs
    6.828: Virtual Memory for User Programs Adam Belay <[email protected]> Plan for today • Previously: Discussed using virtual memory tricks to optimize the kernel • This lecture is about virtual memory for user programs: • Concurrent garbage collection • Generational garbage collection • Concurrent checkpointing • Data-compression paging • Persistent stores What primitives do we need? • Trap: handle page-fault traps in usermode • Prot1: decrease the accessibility of a page • ProtN: decrease the accessibility of N pages • Unprot: increase the accessibility of a page • Dirty: returns a list of dirtied pages since previous call • Map2: map the same physical page at two different virtual addresses, at different levels of protection, in the same address space What about UNIX? • Processes manage virtual memory through higher- level abstractions • An address space consists of a non-overlapping list of Virtual Memory Areas (VMAs) and a page table • Each VMA is a contiguous range of virtual addresses that shares the same permissions and is backed by the same object (e.g. a file or anonymous memory) • VMAs help the kernel decide how to handle page faults Unix: mmap() • Maps memory into the address space • Many flags and options • Example: mapping a file mmap(NULL, len, PROT_READ | PROT_WRITE, MAP_PRIVATE, fd, offset); • Example: mapping anonymous memory mmap(NULL, len, PROT_READ | PROT_WRITE, MAP_PRIVATE | MAP_ANONYMOUS, -1, 0); Unix: mprotect() • Changes the permissions of a mapping • PROT_READ, PROT_WRITE, and PROT_EXEC • Example: make mapping read-only mprotect(addr, len, PROT_READ); • Example: make mapping trap on any acCess mprotect(addr, len, PROT_NONE); Unix: munmap() • Removes a mapping • Example: munmap(addr, len); Unix: sigaction() • Configures a signal handler • Example: get signals for memory access violations act.sa_sigaction = handle_sigsegv; act.sa_flags = SA_SIGINFO; sigemptyset(&act.sa_mask); sigaction(SIGSEGV, &act, NULL); Unix: Modern implementations are very complex e.g.
    [Show full text]