ARIES NETLink™ Multi-Loop Intelligent Fire Alarm-Suppression Control Unit Effective: March 2017 K-76-800 FEATURES • Intelligent addressable multi-loop, suppression-focused control unit • Triple R redundancy provides maximum protection against inadvertent release • Out-of-the-box features: - 2 SLCs with 255 unrestricted addresses each (510 total) - 4 x 40 Display-Keypad - 4 Programmable soft-switches - 2 NACs and 2 R-NACs - 3 Programmable and 1 Trouble Form-C Relays - 2 Auxiliary Power Outputs, 2 amps each - USB ports for PC and printer - RS-232 ports for graphics - 120/240V, 50/60 Hz AC input - 5.4 A Power Supply Unit - Charging Capacity of 165 AH DESCRIPTION - CONTROL UNIT - RS-485 Annunciator bus The ARIES NETLink™ is one of the most technologically - 2-Tier or 3-Tier NEMA 1 Enclosure – fits between 16”studs advanced intelligent fire alarm suppression-focused con- • Suppression systems include: trol units available to the industry today. It combines the - FM-200, FE-13, 3M Novec 1230 Fire Protection Fluid, high quality, system reliability, and flexibility required by mod- Carbon Dioxide, Argonite & Halon Clean Agents ern commercial, high-tech and industrial applications in an - Dry Chemical, Wet Chemical aesthetically-pleasing and physically-robust package. Its - Water-Mist - Sprinkler Supervisory Service modular architecture enables easy field expansion from the - Deluge, Pre-Action, Foam, Foam-Water Systems base 2-SLC unit that supports 510 addressable devices (255 • Modular and expandable per circuit) to an 8-SLC system that supports 2,040 address- - From 3 to 8 SLCs (2,040 addresses) able devices; 130,560 addresses available for a 64-node net- - Up to 96 relays work. - Up to 72 release/NAC circuits The ARIES NETLink is compact, fits between wall stud - Combinations of the above and/or functional modules dimensions, and is designed to be quick and easy to • Networkable up to 64 nodes (130,560 addresses) install. Cutting edge technologies incorporated in the elec- • Flexible programming • High level serviceability and diagnostics tronics design enable diagnostics for time-efficient com- - Ground fault detection by circuit missioning. - 10,000 event log capacity Main Controller Board - MCB - Internet connectivity with e-mail notification feature The ARIES NETLink’s main printed circuit board contains • Modbus RTU, Modbus TCP/IP, BACnet MS/TP and BACnet the system’s central processing unit (CPU) and all of the IP compatibility • Backwards compatible with installed investment primary circuits. The MCB is the heart of the system, con- - SmartOne SLC devices & protocol trolling the operation and supervision of all the system - Kidde Control Heads modules and software. It receives loop device data, pro- -Actuators cesses the data based on pre-programmed instructions, - Legacy PEGAsys panels via simple retrofit kit and transmits output commands to the output modules, • Seamlessly integrated HSSD, ASD and LHD field devices, and display(s). The MCB is mounted to the • Pluggable terminal blocks enclosure using special design hinged standoffs which • User Interface 4 x 40 display supports 4 languages: permit the board to swing left and enable easy access to English, French Canadian, Spanish and Portuguese the PMU/PSU assembly behind. • French Canadian, Spanish and Portuguese Language kit • Approvals/Listings*: User Interface - FM Approved to ANSI/UL864 The user interface consists of a built-in keypad and display - UL Listed No. S2422 which provide physical means by which an operator and/or - cUL Listed No. S2422 installer performs system functions, enters the security - CSFM Approved: No. 7165-1076:0195 password, operates soft keys, navigates the system - California OSHPD Special Seismic Certification Pre- menus, configures and tests the entire ARIES NETLink Approval, No. OSP-0286-10 system. The LCD display supports four languages: English, - NYC Fire Department Certificate of Approval: No. 6092 - City of Chicago Acceptable for Class 1 Applications French, Spanish, and Portuguese (selected from the top- • RoHS compliant level menu). SmartOne Signaling Line Circuit (SLC)-255 devices per circuit (No restrictions on Device Type) 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 B A (-) (+) + - + (-) (-) (+) (+) B A + - + (-) (-) (+) (+) (-) (+) AlarmLin e B A + - + (-) (-) (+) (+) (-) (+) LED LED SW SW CP CPC PC PC PC CP CPC PC PC PC LED LED SW SW CP CPC PC PC PC LED LED SW SW SmartOne APIC TM TM TM 8 7 6 5 4 3 2 1 B A (-) (+) + - + (-) (-) (+) (+) Sm ar tOne Sm ar tOne MODE L A I, N/O MODE L A I, N/O LED LED SW SW 06-235578-001 PC PC PC PC INSTRUCTIONS 06-235578-001 INSTRUCTIONS Sm ar tOne SmartOne MODE L A I, N/O 06-235578-001 INSTRUCTIONS KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 FOR SERVICE SEND TO: DATE OF MANUFACTURE: A.NO.CAT. 70-407008-001 SEE INSTALLATION FOR SERVICE SEND TO: DATE OF MANUFACTURE: A.NO.CAT. 70-407008-001 SEE INSTALLATION MAX. INSTALL. TEMP. 120°F MAX. INSTALL. TEMP. 120°F ALL TERMINALS ARE POWER LIMITED ALL TERMINALS ARE POWER LIMITE D CAT. NO. 70- 407008-SEE INSTALLATION 001 FOR SERVICE SEND TO: DATE OF MANUFACTURE: MAX . INSTALL. TE MP. 120° F ALL TERMINALS ARE POWER LIMITED TM Sm ar tOne MODE L A I, N/O 06-235578-001 INSTRUCTIONS KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 CAT. NO. 70-407008-001 SEE INSTALLATION FOR SERVICE SEND TO: DATE OF MANUFACTURE: MAX. INSTALL. TEMP. 120°F ION PHOTO THERMAL ALL TERMINALS ARE POWER LIMITED (CPD-7052) (PSD-7152) (THD-7252) SUPPRES SION SYSTEM ABOR T PUSH PULL Abort LHS AlarmLine DAF Station ORION XT Manual AIR-Intelligence High Sensitivity Release Air Sampling Smoke Detection Remote Display Detection Control Modules (RDCMs),1-15 Remote Releasing - HVAC R 7 6 5 3 2 1 A E 4 + - + (-) (-) (+) (+) N/C N/O Module COM - Shutdowns G L PC PC PC PC E E N A : TM 1 ADDRESSABLE RELEASE MODULE T S E 120°F TEMP. 7 ARE POWER LIMITED - Doors and Dampers RVICE SENDRVICE TO: MODEL AO SmartOne 06-235577-001 INSTRUCTIONS KIDDE-FENWAL, INC. KIDDE-FENWAL, 400 MAIN ST. ASHLAND, MA 0172 CAT. NO. 70-408004-001 CAT. SEE INSTALLATION FOR SE DATE OF MANUFACTURE DATE MAX. INSTALL. TERMINALS 5- TERMINALS 1-4 ARE POWER LIMITED - Elevator Recall LED Annunciator ASM Horns/ Relay Modules (LAMs), Suppression Release Strobes Module 1-16 Release Additional SLCs Relay Outputs Internet Communications Module (ICM) BACnet/Modbus USB and/or Serial Connection for Laptop and Printer Interface Backplane ARIES NETLink Control Panel Card Cage 1 2 3 4 5 6 1 Signal Line Circuit (SLC) Card 2 Network Interface Card (NIC) 3 Relay Card 4 City Tie Card 5 Release/Notification Appliance Circuit (R-NAC) Card 6 Digital Alarm Communicator Transmitter (DACT) Figure 1. Modular Design to Meet the Most Demanding Applications - 2 - MAIN CONTROLLER BOARD SPECIFICATION (Continued) User Interface Maximum Output Current: Non-Synchronized: 2.0 A Synchronized: 1.5 A Maximum Output Circuit 28 VDC Terminal Voltage: Minimum Output Circuit 20 VDC Terminal Voltage: End-of-Line Resistor: 10 K, 5%, 1/2 W Maximum Allowable Voltage 2 V at End-of-Line Drop: MCB Release/Notification Appliance Circuits Number of Circuits: Two Individually Configurable for Notification or Release: Yes Notification Specifications: Same as NAC Release Specifications: Main Controller Board (MCB) Compatible devices: • Kidde Control head: max 1 Figure 2. Main Controller Board and User Interface • Water Mist Solenoid valve: max 1 • FM Group A, B, D, E, F, G, MAIN CONTROLLER BOARD SPECIFICATION I, J or K Solenoid: max 1 • Metron actuator: -P/N 83-132500-500 max 1 MCB Signaling Line Circuits -P/N 83-131082-001 max 1 Number of Circuits: Two Device type configurable: Yes, with device on- Device Capacity: 255 devices per SLC time after activation Device Type Restriction: None Wiring Classes: Wiring Classes: Class A, B or X • Solenoids: Class A or B T-Tapping Allowed: Class B only •Actuators: Class B Circuit Voltage: Nominal 24 VDC Power Limited: Yes, requires In-Line Maximum Line Resistance: 40 ohms per loop diode device Maximum Capacitance: 0.5 µF Maximum Output Circuit Terminal Voltage: 28 VDC Maximum Current: 350 mA (short circuit) End-of-Line Resistor: 10 K, 5%, 1/2 W Wiring Specifications: Twisted #14AWG - #18AWG, unshielded, Allowable Voltage Drop: 2 V low-capacitance wire with a nominal wire-to- MCB Relays wire capacitance of Number and type: 3 Programmable and approximately 20 pf. 1 Trouble Relay Relay Form: Form-C (1 NO + 1 NC) MCB Notification Appliance Circuits Rating: 3A @ 30 VDC/120 VAC Number of Circuits: Two Compatible devices: 24 VDC polarized horns, strobes, bells, etc. Wiring Classes: Class A or B Power Limited: Yes Synchronized Strobes: Yes, configurable - 3 - MAIN CONTROLLER BOARD SPECIFICATION (Continued) POWER SUPPLY & MANAGEMENT SPECIFICATION MCB RS-232 Serial Ports Number of PMUs per Minimum: 1 Number of Ports: 2 control unit Maximum: 4 Specifications: Bi-Directional 9600 Number of PSUs per PMU Minimum: 1 Baud, 8 Data Bits, 1 Maximum: 2 Stop Bit, No Parity Primary AC Input Power: • 1 PSU: 120 VAC, 50/60 Hz, MCB RS-485 Annunciator Port 3.2 A Number of Ports: 1 240 VAC, 50/60 Hz, 1.6 A Compatible Devices: •RDCM Max. 15 devices • 2 PSU: 120 VAC, 50/60 Hz, •R-LAM Max. 16 devices 6.4 A •ATM-L Max. 16 devices 240 VAC, 50/60 Hz, •ATM-R Max. 16 devices 3.2 A Compatible Device 31 in any order Allowable Input Voltage 115 + 5% VAC Maximum: Variation: 230 + 4% VAC Wiring Type: Twisted, shielded, low- Secondary DC Output: capacitance fire alarm • 1 PSU: 5.4 A @ 27.6 VDC wire • 2 PSU: 10.8 A @ 27.6 VDC Wiring Minimum Size: AWG 18 Voltage Selection: Slide switch on PSU Maximum wire length: 4,000 ft.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages14 Page
-
File Size-