Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites 1

Total Page:16

File Type:pdf, Size:1020Kb

Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites 1 Contents 1. Introduction ....................................................................................................... 1 2. Why use passive samplers? The advantages .................................................. 2 3. What passive samplers tell us ........................................................................... 5 4. Types of passive samplers ................................................................................ 7 5. Some theory on how passive samplers work .................................................... 9 6. Preparing, deploying, recovering, and storing passive samplers .....................11 7. Selecting passive samplers ............................................................................. 15 8. Analyzing passive sampler data ...................................................................... 15 9. Brief case study ............................................................................................... 19 10. Remaining scientific challenges in using passive samplers ............................ 20 11. US EPA contacts working with passive samplers ........................................... 22 12. Summary ......................................................................................................... 22 13. Acknowledgements ......................................................................................... 24 14. References used in this document ................................................................. 25 Appendix A ........................................................................................................... 29 Mention of trade names or commercial products in this document does not constitute the U.S. Environmental Protection Agency’s endorsement or recommendation for use. i Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites 1. Introduction The objective of this Sediment Assessment and Monitoring Sheet (SAMS) is to provide introductory information on the use of passive samplers at Superfund sediment sites contaminated with hydrophobic organic contaminants. The concept of passive sampling in the environment was first developed in the 1980s, and samplers started to be deployed in the field for research purposes in the 1990s. Since then, passive samplers have been used for monitoring contaminant concentrations in the water column, soil and sediment interstitial waters, and air at sites around the world. Their use in sediments to date has been primarily for research, however. As discussed below, passive samplers are useful new tools for assessing contaminant exposures and evaluating the potential for adverse environmental effects at Superfund sites. After reading this SAMS, users will have a fundamental understanding of some common passive samplers and their potential applications at Superfund sites. This SAMS discusses passive samplers that can be used in both water column and sediment deployments, and in some cases both simultaneously. These passive samplers use polyethylene (PE), polyoxymethylene (POM), and solid phase micro-extraction (SPME) materials. Another type of passive sampler called semi-permeable membrane devices (SPMDs) have been used primarily in the water column as surrogates for biota such as fish, but will not be discussed here in any depth. When deployed together, passive samplers placed in the water column and in the sediment can provide information about contaminant gradients between the sediment and the water. For example, when an engineered cap is used as part of a site cleanup, passive samplers can be used as a monitoring tool to evaluate the contaminant flux from the underlying contaminated sediment, into the cap layers and into the overlying water. Passive samplers collect information about the dissolved concentrations of contaminants. The dissolved concentration is a useful measure of the amount of contaminant that is bioavailable to aquatic organisms. Passive samplers do not provide information about the concentrations of contaminants associated with bedded, suspended or colloidal particles in aquatic systems and therefore do not address directly the transport of contaminants associated with such particles. The focus of this document is on a subset of those contaminants of concern (COC) often found at Superfund sites that, chemically speaking, are known as the hydrophobic or nonionic organic chemicals. These include polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), polychlorinated dioxins and furans (PCDD/Fs) and chlorinated pesticides such as DDT. These chemicals are particularly persistent in the environment and bioaccumulate in aquatic organisms, often drive the risks as Superfund sediment sites, and are the focus of this SAMS. Metal COC such as cadmium, copper, lead, mercury and zinc are not discussed. There is a growing scientific literature on using other types of passive samplers to monitor metals, but the field is not as established, and that work is beyond the scope of this SAMS. This document briefly discusses the use of passive samplers but does not provide specific protocols on deployment and recovery, nor does it describe the chemical analysis procedures for passive samplers (it is not a U.S. Environmental Protection Agency [EPA] standard method or operating procedure). However, with the increasing use of passive samplers at sites around the United States and the world, these types of specialized protocols and procedures are likely to be available in the near future. United States Office of Superfund Remediation and OSWER Directive 9200.1-110 FS Environmental Protection Technology Innovation, and December 2012 Agency Office of Research and Development 1 Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites 2. Why Use Passive Samplers? The Advantages At Superfund sites, there often is the need to know the concentrations of hydrophobic organic contaminants in the water column and sediment interstitial water, and to understand the relationship between these levels and the total levels in the sediment (i.e., bulk sediment chemistry). Depending on the contaminant, there may be several ways to Information Box 1 Environmental phases are often measure these concentrations. The typical used to divide the aquatic environment into separate analytical methods are gas chromatography components, each with its own unique characteristics. with mass spectroscopy (GC/MS) or electron Understanding environmental phases and where a capture detection (GC/ECD) for most of the contaminant resides in these phases can assist in contaminants considered in this SAMS. These establishing whether the contaminants will be in a methods measure the quantity of these form resulting in exposure to aquatic organisms, wildlife and humans. Principal environmental phases contaminants in a selected matrix like water or important to contaminated sediment sites are defined sediment. However, before the analysis can be in Table 1. Definitions are generally based on the performed, it is necessary to collect the sample particle size or chemical qualities (e.g., sorption matrix and extract the contaminants from that strength of carbon types) of the substances making-up matrix. For the last 40 years, these hydrophobic the phase. Hydrophobic organic chemicals partition contaminants have been extracted from a between these environmental phases. In general, the volume of water or mass of sediment using majority of these contaminants will be associated with organic solvents. This conventional approach the particulate phase and are not typically readily has several disadvantages. First, for water bioavailable to result in an exposure. A portion of samples, even at the most contaminated sites, these contaminants will also associate with the colloidal and dissolved organic carbon (DOC) phases, contaminant concentrations are frequently so where they are also not readily bioavailable. Often the low that they are not detectable with the GC/MS least amount of contaminants will be in the truly or GC/ECD unless very large volumes of water dissolved phase, but this is the phase where they are (e.g., tens to thousands of liters) are extracted. the most readily bioavailable for exposure and uptake Furthermore, even when contaminants can be by organisms. detected, the results are often affected by Particulate sample artifacts like the presence of very small sediment particles, colloids and dissolved organic carbon (DOC), and thus the measured Dissolved Contaminant Truly concentrations do not represent the truly Organic of Dissolved Carbon Concern dissolved and bioavailable concentrations. These additional environmental phases (defined Information Box #1 Colloids in Table 1 and discussed in ) can result in overestimations of the dissolved The image above shows the partitioning of a concentrations in the water column and hydrophobic COC between the principal interstitial water. Second, for sediments, environmental phases, with the thickness of the solvent extraction removes nearly all of the arrows indicating the relative degree to which a contaminants from the sediment, including that contaminant associates with a given phase (based on Schwarzenbach and others (2003)). portion tightly bound or sequestered in the sediment matrix. While this type of information is useful for quantifying the total mass of United States Office of Superfund Remediation and OSWER Directive 9200.1-110 FS Environmental Protection Technology Innovation, and December
Recommended publications
  • Development and Application of Passive Samplers for Assessing Air and Freely Dissolved Concentrations of Hydrophobic Organic Contaminants
    Development and Application of Passive Samplers for Assessing Air and Freely Dissolved Concentrations of Hydrophobic Organic Contaminants by Adesewa A. Odetayo, B.Tech., M.Sc. A Dissertation In Civil, Environmental and Construction Engineering Submitted to the Graduate Faculty of Texas Tech University in Partial Fulfillment of the Requirements for the Degree of DOCTOR OF PHILOSOPHY Approved Dr. Danny D. Reible Chair of Committee Dr. Chongzong Na Dr. Weile Yan Dr. Mark Sheridan Dean of the Graduate School December 2020 Copyright 2020, Adesewa Odetayo Texas Tech University, Adesewa Odetayo, December 2020 Acknowledgements This research was supported by funding from U.S Army Corps of Engineer (USACE) and U.S Army Engineer Research Development Center (ERDC) (contract # W912HZ-17-2-0019), and the Environmental Security Technology Certificate Program (ESTCP) (contract # ER 201735). Special thanks to the crew from ERDC for their support during all the field sampling trips. Firstly, my sincere appreciation goes to my supervisor, Dr. Danny Reible for his help, guidance, and tremendous support throughout the course of my doctoral study, without whom I would have accomplished this milestone. I would like to also extend my gratitude to my committee members for their time and constructive inputs to my research. My Doctoral research experience was made possible because of so many individuals starting with Magdalena Rakowska, who is always available to help and provide intellectual insights pertaining my research. My adopted brother, Uriel de Jesús Garza Rubalcava who cheered me up and always available to help. Tariq Hussain and Alex Smith who I would most likely meet in the Lab at nights or weekends working on their individual research and fellow passive sampling buddy.
    [Show full text]
  • Redalyc.Passive Sampling in the Study of Dynamic and Environmental
    Revista Facultad de Ingeniería Universidad de Antioquia ISSN: 0120-6230 [email protected] Universidad de Antioquia Colombia Narvaez V., Jhon F.; Lopez, Carlos A.; Molina P., Francisco J. Passive sampling in the study of dynamic and environmental impact of pesticides in water Revista Facultad de Ingeniería Universidad de Antioquia, núm. 68, febrero-septiembre, 2013, pp. 147- 159 Universidad de Antioquia Medellín, Colombia Disponible en: http://www.redalyc.org/articulo.oa?id=43029811014 Cómo citar el artículo Número completo Sistema de Información Científica Más información del artículo Red de Revistas Científicas de América Latina, el Caribe, España y Portugal Página de la revista en redalyc.org Proyecto académico sin fines de lucro, desarrollado bajo la iniciativa de acceso abierto Rev. Fac. Ing. Univ. Antioquia N.° 68 pp. 147-159. Septiembre, 2013 Passive sampling in the study of dynamic and environmental impact of pesticides in water Muestreadores pasivos en el estudio de la dinámica de plaguicidas y el impacto ambiental en el agua Jhon F. Narvaez V. *1 Carlos A. Lopez2 Francisco J. Molina P.1 1Grupo de Investigación en Gestión y Modelación Ambiental-GAIA. Facultad de Ingeniería, Universidad de Antioquia A.A. 1226. Calle 67 Nº 53-108. Medellín, Colombia. 2Laboratorio Análisis de Residuos. Instituto de Química. Universidad de Antioquia A.A. 1226. Calle 67 Nº 53-108. Medellín, Colombia. (Recibido el 9 de agosto de 2012. Aceptado el 5 de agosto de 2013) Abstract Pesticides are the most applied substances in agricultural activities which can contaminate water bodies by direct or indirect discharge, but large volumes and natural transformation processes can decrease the concentration of these substances and their degradates in watershed.
    [Show full text]
  • Passive Sampling of Groundwater Wells for Determination of Water Chemistry
    Passive Sampling of Groundwater Wells for Determination of Water Chemistry Chapter 8 of Section D. Water Quality Book 1. Collection of Water Data by Direct Measurement Techniques and Methods 1–D8 U.S. Department of the Interior U.S. Geological Survey A B C D E F H G Cover. (A) Figure 15 from report, AGI Sample Module®. Photograph from Mark Arnold, Amplified Geophysical Imaging, LLC. (B) Figure 11A from report, an EON Products, Inc. Dual Membrane (DM) sampler®. Photograph by Bradley P. Varhol, EON Products, Inc. (C) Figure 7B from report a 2.5-inch-diameter regenerated cellulose dialysis membrane sampler with external supports after assembly. Photograph by Thomas E. Imbrigiotta, U.S. Geological Survey. (D) Figure 17A from report, A downhole semi-permeable membrane device (SPMD) sampler. Photograph and diagram by David A. Alvarez, U.S. Geological Survey. (E) A series of nylon screen samplers retrieved from a profile of the water column of a well showing capped bottles and the removed tops. The variation of iron-staining on the removed tops indicates stratified flow with different redox conditions occurs under ambient flow conditions in the well. Photograph by Philip T. Harte, U.S. Geological Survey. (F) Figure 5A from report, a polyethylene diffusion bag sampler. Photograph by Bradley P. Varhol, EON Products, Inc. (G) Figure 9 from report, a rigid porous polyethylene sampler, without protective mesh and with protective mesh, in a water-filled tube for shipment. Photographs by Leslie Venegas, ALS Global. (H) Figure 13A from report, QED Environmental Systems, Inc. Snap Sampler® with volatile organic compound bottle (40-milliliter vial).
    [Show full text]
  • Preparation and Performance Features of Wristband Samplers and Considerations for Chemical Exposure Assessment
    OPEN Journal of Exposure Science and Environmental Epidemiology (2017) 27, 551–559 www.nature.com/jes ORIGINAL ARTICLE Preparation and performance features of wristband samplers and considerations for chemical exposure assessment Kim A. Anderson1, Gary L. Points III1, Carey E. Donald1, Holly M. Dixon1, Richard P. Scott1, Glenn Wilson1, Lane G. Tidwell1, Peter D. Hoffman1, Julie B. Herbstman2 and Steven G. O’Connell1 Wristbands are increasingly used for assessing personal chemical exposures. Unlike some exposure assessment tools, guidelines for wristbands, such as preparation, applicable chemicals, and transport and storage logistics, are lacking. We tested the wristband’s capacity to capture and retain 148 chemicals including polychlorinated biphenyls (PCBs), pesticides, flame retardants, polycyclic aromatic hydrocarbons (PAHs), and volatile organic chemicals (VOCs). The chemicals span a wide range of physical–chemical properties, with log octanol–air partitioning coefficients from 2.1 to 13.7. All chemicals were quantitatively and precisely recovered from initial exposures, averaging 102% recovery with relative SD ≤ 21%. In simulated transport conditions at +30 °C, SVOCs were stable up to 1 month (average: 104%) and VOC levels were unchanged (average: 99%) for 7 days. During long-term storage at − 20 °C up to 3 (VOCs) or 6 months (SVOCs), all chemical levels were stable from chemical degradation or diffusional losses, averaging 110%. Applying a paired wristband/active sampler study with human participants, the first estimates of wristband–air partitioning coefficients for PAHs are presented to aid in environmental air concentration estimates. Extrapolation of these stability results to other chemicals within the same physical–chemical parameters is expected to yield similar results.
    [Show full text]
  • Passive Sampling of Polychlorinated Biphenyls (Pcb) in Indoor Air: Towards a Cost-Effective Screening Tool
    PASSIVE SAMPLING OF POLYCHLORINATED BIPHENYLS (PCB) IN INDOOR AIR: TOWARDS A COST-EFFECTIVE SCREENING TOOL Scientifi c Report from DCE – Danish Centre for Environment and Energy No. 128 2014 AARHUS AU UNIVERSITY DCE – DANISH CENTRE FOR ENVIRONMENT AND ENERGY [Blank page] PASSIVE SAMPLING OF POLYCHLORINATED BIPHENYLS (PCB) IN INDOOR AIR: TOWARDS A COST-EFFECTIVE SCREENING TOOL Scientifi c Report from DCE – Danish Centre for Environment and EnergyNo. 128 2014 Katrin Vorkamp1 Philipp Mayer2 1 Aarhus University, Department of Environmental Science 2 Technical University of Denmark (DTU), Department of Environmental Engineering AARHUS AU UNIVERSITY DCE – DANISH CENTRE FOR ENVIRONMENT AND ENERGY Data sheet Series title and no.: Scientific Report from DCE – Danish Centre for Environment and Energy No. 128 Title: Passive sampling of polychlorinated biphenyls (PCB) in indoor air: Towards a cost- effective screening tool Author: Katrin Vorkamp1 and Philipp Mayer2 Institutions: 1Aarhus University, Department of Environmental Science 2Technical University of Denmark (DTU), Department of Environmental Engineering Publisher: Aarhus University, DCE – Danish Centre for Environment and Energy © URL: http://dce.au.dk/en Year of publication: January 2015 Editing completed: December 2014 Quality assurance, DCE: Susanne Boutrup Financial support: Danish Energy Agency Please cite as: Vorkamp, K. & Mayer, P. 2015. Passive sampling of polychlorinated biphenyls (PCB) in indoor air: Towards a cost-effective screening tool. Aarhus University, DCE – Danish Centre for Environment and Energy, 118 pp. Scientific Report from DCE – Danish Centre for Environment and Energy No. 128. http://dce2.au.dk/pub/SR128.pdf Abstract: PCBs were widely used in construction materials in the 1906s and 1970s, a period of high building activity in Denmark.
    [Show full text]
  • Aquatic Global Passive Sampling
    University of Rhode Island DigitalCommons@URI Graduate School of Oceanography Faculty Graduate School of Oceanography Publications 2017 Aquatic Global Passive Sampling (AQUA-GAPS) Revisited – First Steps towards a Network of Networks for Organic Contaminants in the Aquatic Environment Rainer Lohmann University of Rhode Island, [email protected] Derek Muir See next page for additional authors Follow this and additional works at: https://digitalcommons.uri.edu/gsofacpubs The University of Rhode Island Faculty have made this article openly available. Please let us know how Open Access to this research benefits oy u. This is a pre-publication author manuscript of the final, published article. Terms of Use This article is made available under the terms and conditions applicable towards Open Access Policy Articles, as set forth in our Terms of Use. Citation/Publisher Attribution Lohmann, Rainer; Muir, Derek; Zeng, Eddy; Bao, Lian-Jun; Allan, Ian; Arinaitwe, Kenneth; Booij, Kees; Helm, Paul; Kaserzon, Sarit; Mueller, Jochen; Shibata, Yasuyuki; Smedes, Foppe; Tsapakis, Manolis; Wong, Charles; You, Jing. "Aquatic Global Passive Sampling (AQUA-GAPS) Revisited – First Steps towards a Network of Networks for Organic Contaminants in the Aquatic Environment". Environ Sci Technol 2017, 51, 1060-1067. DOI: 10.1021/acs.est.6b05159 Available at: http://dx.doi.org/10.1021/acs.est.6b05159 This Article is brought to you for free and open access by the Graduate School of Oceanography at DigitalCommons@URI. It has been accepted for inclusion in Graduate School of Oceanography Faculty Publications by an authorized administrator of DigitalCommons@URI. For more information, please contact [email protected]. Authors Rainer Lohmann, Derek Muir, Eddy Y.
    [Show full text]
  • Time-Integrated Passive Sampling As a Complement to Conventional
    Prepared in cooperation with the Eugene Water & Electric Board Time-Integrated Passive Sampling as a Complement to Conventional Point-in-Time Sampling for Investigating Drinking-Water Quality, McKenzie River Basin, Oregon, 2007 and 2010–11 Scientific Investigations Report 2013–5215 U.S. Department of the Interior U.S. Geological Survey Time-Integrated Passive Sampling as a Complement to Conventional Point-in-Time Sampling for Investigating Drinking-Water Quality, McKenzie River Basin, Oregon, 2007 and 2010–11 By Kathleen A. McCarthy and David A. Alvarez Prepared in cooperation with the Eugene Water & Electric Board Scientific Investigations Report 2013–5215 U.S. Department of the Interior U.S. Geological Survey U.S. Department of the Interior SALLY JEWELL, Secretary U.S. Geological Survey Suzette M. Kimball, Acting Director U.S. Geological Survey, Reston, Virginia: 2014 For more information on the USGS—the Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment, visit http://www.usgs.gov or call 1–888–ASK–USGS. For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod To order this and other USGS information products, visit http://store.usgs.gov Any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Although this information product, for the most part, is in the public domain, it also may contain copyrighted materials as noted in the text. Permission to reproduce copyrighted items must be secured from the copyright owner. Suggested citation: McCarthy, K.A., and Alvarez, D.A., 2014, Time-integrated passive sampling as a complement to conventional point- in-time sampling for investigating drinking-water quality, McKenzie River Basin, Oregon, 2007 and 2010–11: U.S.
    [Show full text]
  • Review of the Background and Application of Triolein-Containing Semipermeable Membrane Devices in Aquatic Environmental Study
    University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln USGS Staff -- Published Research US Geological Survey 2002 Review of the background and application of triolein-containing semipermeable membrane devices in aquatic environmental study Yibing Lu Research Center for Eco-Enironmental Sciences Zijian Wang Research Center for Eco-Enironmental Sciences, [email protected] James Huckins Columbia Enironmental Research Center, [email protected] Follow this and additional works at: https://digitalcommons.unl.edu/usgsstaffpub Lu, Yibing; Wang, Zijian; and Huckins, James, "Review of the background and application of triolein- containing semipermeable membrane devices in aquatic environmental study" (2002). USGS Staff -- Published Research. 552. https://digitalcommons.unl.edu/usgsstaffpub/552 This Article is brought to you for free and open access by the US Geological Survey at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in USGS Staff -- Published Research by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln. Aquatic Toxicology 60 (2002) 139–153 www.elsevier.com/locate/aquatox Review Review of the background and application of triolein-containing semipermeable membrane devices in aquatic environmental study Yibing Lu a, Zijian Wang a,*, James Huckins b a State Key Laboratory of En6ironmental Aquatic Chemistry, Research Center for Eco-En6ironmental Sciences, Beijing 100085, China b Columbia En6ironmental Research Center, USGS, Columbia, MO, USA Received 5 March 2002; accepted 15 April 2002 Abstract This paper briefly reviews research on passive in situ samplers for aquatic environments but focuses on the development and application of the triolein-containing semipermeable membrane device in aquatic environmental monitoring. Special attention is paid to the calibration of the devices, quality control issues, and its potential uses in environmental assessments of aquatic contaminants.
    [Show full text]
  • Passive Sampling Methods for Contaminated Sediments: State Of
    Integrated Environmental Assessment and Management — Volume 10, Number 2—pp. 179–196 © 2014 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of SETAC. 179 Passive Sampling Methods for Contaminated Sediments: State of the Science for Metals Willie JGM Peijnenburg,*yz Peter R Teasdale,§ Danny Reible,k Julie Mondon,# William W Bennett,§ and Peter GC Campbellyy yInstitute of Environmental Sciences (CML), University of Leiden, Leiden, The Netherlands zNational Institute for Public Health and the Environment, Center for Safety of Substances and Products, Bilthoven, The Netherlands §Environmental Futures Research Institute, School of Environment, Griffith University, Gold Coast Campus, Southport, Australia kDepartment of Civil and Environmental Engineering, Texas Tech University, Lubbock, Texas, USA #Center for Integrated Ecology, Environmental Sustainability Research Cluster, Deakin University, Warrnambool Campus, Warrnambool, Victoria, Australia yyUniversité du Québec, Institut National de la Recherche Scientifique, Centre Eau, Terre et Environnement, Québec, Canada (Submitted 18 July 2013; Returned for Revision 23 August 2013; Accepted 1 November 2013) Special Series EDITOR'S NOTE: This paper represents 1 of 6 papers in the special series “Passive Sampling Methods for Contaminated Sediments,” which was generated from the SETAC Technical Workshop “Guidance on Passive Sampling Methods to Improve Management of Contaminated Sediments,” held November 2012 in Costa Mesa, California, USA. Recent advances in passive sampling methods (PSMs) offer an improvement in risk‐based decision making, since bioavailability of sediment contaminants can be directly quantified. Forty‐five experts, representing PSM developers, users, and decision makers from academia, government, and industry, convened to review the state of science to gain consensus on PSM applications in assessing and supporting management actions on contaminated sediments.
    [Show full text]
  • Groundwater Quality Measurement with Passive Samplers Code of Best Practices
    Groundwater quality measurement with passive samplers Code of best practices Groundwater quality measurement with passive samplers - Code of best practices 2 Summary In Europe, passive sampling is an emerging way of measuring groundwater quality and therefore of characterizing and monitoring polluted sites. In the USA, the scientific literature is abundant on the subject and a lot of studies were conducted to assess their efficiency to measure groundwater quality. Nevertheless, in the frame of a previous project (the METROCAP project), a survey was conducted amongst French consultants and showed that passive samplers were not widely used in France because there was a need to provide feedback and guidelines to promote the use of passive samplers in a regulatory context. The situation seems quite similar in the other European countries. In this context, after a general presentation of the different groundwater sampling techniques and particularly passive sampling, this report provides some feedback on the use of 4 passive samplers in the frame of the CityChlor project: PDBs (polyethylene diffusion bags), regenerated cellulose dialysis membranes, ceramic dosimeters and Gore sorber modules. In general, passive samplers seem technically and economically interesting to measure groundwater quality at contaminated sites because they showed a lot of advantages comparing to the conventional sampling technique: they were easy to install and retrieve, no external energy source or additional equipment was needed, no purge water was produced, no filtration was required on site and no cross contamination occurred. In addition they were generally more cost-effective than the conventional sampling technique. They could be seen as complementary tools to the conventional sampling technique, giving access to information that are not or hardly available with the conventional sampling technique, such as depth discrete samples or vertical contaminant profiling when deployed in series.
    [Show full text]
  • Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods
    applied sciences Review Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods Liyang Wang 1,2 , Ruixia Liu 1,2,*, Xiaoling Liu 1 and Hongjie Gao 1 1 State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; [email protected] (L.W.); [email protected] (X.L.); [email protected] (H.G.) 2 College of Water Sciences, Beijing Normal University, Beijing 100875, China * Correspondence: [email protected]; Tel.: +86-10-8491-9726-601; Fax: +86-10-8491-7906 Received: 28 June 2020; Accepted: 7 August 2020; Published: 11 August 2020 Abstract: As a passive sampling device, the polar organic chemical integrative sampler (POCIS) has the characteristics of simple operation, safety, and reliability for assessing the occurrence and risk of persistent and emerging trace organic pollutants. The POCIS, allowing for the determination of time-weighted average (TWA) concentration of polar organic chemicals, exhibits good application prospects in aquatic environments. Before deploying the device in water, the sampling rate (Rs), which is a key parameter for characterizing pollutant enrichment, should be determined and calibrated accurately. However, the Rs values strongly depend on experimental hydrodynamic conditions. This paper provides an overview of the current situation of the POCIS for environmental monitoring of organic pollutants in an aquatic system. The principle and theory of the POCIS are outlined. In particular, the effect factors such as the ambient conditions, pollutant properties, and device features on the Rs are analyzed in detail from aspects of impact dependence and mechanisms.
    [Show full text]
  • Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User’S Manual
    EPA-600-R-16-357 Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User’s Manual February 2017 Final Web Version (1.0) Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User’s Manual Robert M. Burgess U.S. Environmental Protection Agency National Health and Environmental Effects Research Laboratory Atlantic Ecology Division, Narragansett, RI, USA Susan B. Kane Driscoll Exponent, Inc. Maynard, MA, USA G. Allen Burton Cooperative Institute for Limnology & Ecosystems Research University of Michigan Water Center Ann Arbor, MI, USA Upal Ghosh Department of Chemical, Biochemical, & Environmental Engineering University of Maryland Baltimore County Baltimore, MD, USA Philip M. Gschwend Parsons Laboratory for Environmental Science and Engineering Massachusetts Institute of Technology Cambridge, MA, USA Danny Reible Department of Civil and Environmental Engineering Texas Tech University Lubbock, TX, USA Sungwoo Ahn Exponent, Inc. Bellevue, WA, USA Tim Thompson Science and Engineering for the Environment, LLC Seattle, WA 98105 U.S. Environmental Protection Agency Office of Research and Development National Health and Environmental Effects Research Laboratory Atlantic Ecology Division, Narragansett, RI 02882 Strategic Environmental Research and Development Program (SERDP)/ Environmental Security Technology Certification Program (ESTCP) 4800 Mark Center Dr. Alexandria, VA 22350 PASSIVE SAMPLING: USER’S MANUAL Notice The Department of Defense’s Strategic Environmental Research and Development Program (SERDP)/Environmental Security Technology Certification Program (ESTCP) and U.S. EPA’s Office of Research and Development (ORD) produced this document as a guide for using passive sampling to evaluate contaminated sediments. The document is intended to cover the laboratory, field, and analytical aspects of passive sampler applications.
    [Show full text]