Known Issues Winidea
Total Page:16
File Type:pdf, Size:1020Kb
List of known issues for winIDEA 9.21.9.0.118566 Issue ID Severity Description General Certain function(s) can be missing in the Callstack view when stepping in the body part of the function (MPC5777M application compiled S004073 Medium with GHS). S001177 Medium winIDEA connection stops working after several hours of active debug session. S004061 Medium Call Stack doesn't work (ARM Cortex-M application compiled with GHS compiler). S004058 Medium Cannot view float type variables in Locals view (ARM Cortex-M code compiled with GHS compiler). S003658 Medium Go to... after download operation is not supported for secondary cores. S002844 Low winIDEA becomes unresponsive if CPU Options are changed when winIDEA terminal is connected to SoC and SoC is running. Infineon S003288 Medium winIDEA trace unreliable if interrupt hits on traced function exit (Infineon TC3xx). S004163 Medium winIDEA hangs after writing to Flash memory via memory window (Infineon TC298TP). S004136 Medium Download does not program application correctly to PFlash if PFlash Program Empty Cells option is deselected (Infineon TC3xx). S003996 Medium Reset is not stable (Infineon TLE9844). S003803 Medium Flash Blank Check after Mass Erase does not work if secondary cores are running (Infineon TC298TP). S003792 Medium BlueBox loses control over the CPU when an external target reset is applied (Infineon TC298TF). S003330 Medium Start of trace session over AGBT trace protocol fails with faulty error message (Infineon TC277TE). iSYSTEM FBridge debug sync doesn't work when Infineon TC3xx is configured as a master workspace and used in conjunction with S003225 Medium Infineon AGBT Aurora Active Probe (Infineon TC3xx). Swapping tracing data from multiple cores, then in the next trace session from single core and in the next trace session again from S003174 Medium multiple cores, data are not traced from all configured cores (Infineon TC399XE). List of known issues for winIDEA 9.21.9.0.118566 Infineon Correlation between AOM CAN trace and SoC data trace yields incorrect timeline ordering of the events (Infineon TriCore TC2xx and S000221 Low TC3xx). Other S004088 Medium Flash mass erase doesn't work (Vorago VA10800). NXP S003548 Medium Programming very large files to the QSPI flash can fail (NXP LS1021A). S002344 Medium Recording longer application loop with MTB trace hangs winIDEA (NXP Kinetis MKM34Z256) S004151 Medium Terminal window doesn't display ITM trace data. (NXP S32K148). S004111 Medium End of the ETB trace recording missing when recording in continuous mode (NXP LPC4357). S003441 Medium Program trace works unreliably (NXP i.MX6UL). S002813 Low Flash Blank Check also checks 0x400-0x40F flash region, even though it should never be erased (NXP Kinetis KL03). S002797 Medium Debug reset executes unreliably (NXP i.MX RT0162). S002732 Medium Flash programming doesn't work (NXP Kinetis KL25Z). S001954 Medium Download sometimes fails (NXP i.MX RT1050). S000673 Low testIDEA fails to modify floating point registers (NXP LPC54114). ST S001771 Medium Stopping the CPU fails while it’s in Standby low power mode (ST STM32L053). S004066 Medium Secondary core goes to exception handler after reset on primary core (ST STA1385). List of known issues for winIDEA 9.21.9.0.118566 ST S003900 Medium Mass erase slow on external QSPI, if SWD protocol is used to connect to SoC (ST STM32MP157). S003805 Medium winIDEA reset does not reset secondary cores (ST STA1385). S001331 Low Coverage does not work if 'All' is selected for Scope in the Coverage configuration (ST STA1385). Renesas S001396 Low Timestamps of STM trace via HSSTP do not start from 0 on new trace recording (Renesas R-CAR H3v2). S004120 Medium daqIDEA data acquisition doesn't work (Renesas RH850). S004091 Medium Endless Coverage Auto Resume does not work (Renesas RH850). S003991 Low Establishing debug session isn't always successful if executed quickly via scripts (Renesas RH850/F1H). S003802 Medium Programming of Cypress S26Kx512 HyperFlash memory unstable (Renesas R-CAR V3H). S003527 Low Attach to SoC after winIDEA Detach operation resets SoC (Renesas RH850/P1M). If winIDEA Analyzer is first run with enabled on-chip trace and then with disabled on-chip trace (Manual Trigger Configuration) in same S003202 Medium debug session, second run will still record on-chip trace (Renesas RH850). Trigger on both, data write and specific data value match, doesn't work on ARM CoreSight ETMv4 trace source component (Renesas R- S002901 Medium Car V3H). S002695 Medium Aurora trace stops working after a while if maximum Aurora trace clock is used (Renesas RH850/P1H-C). S001978 Low Floating point structure is not handled correctly in testIDEA (Renesas RZ/A1LU). S001485 Low Sometimes data trace is incomplete if iC6000 is connected to PC via USB (Renesas RH850/P1H-C). Cypress S004142 Medium Starting the SWO Trace on Cortex-M4 core breaks the debug session (Cypress CYT2B7) List of known issues for winIDEA 9.21.9.0.118566 Cypress S001353 Medium Setting/clearing execution breakpoint doesn't work while in Standby low power mode (Cypress Traveo-II CYT2B7). S003824 Medium Application doesn't run on Run debug action (primary core) when started from Reset exception vector (Cypress CYT2B9). S003783 Medium If application is run already before programming the Flash, programming can fail (Cypress CY8C4245). S003662 Medium Data trace on secondary core doesn't work (Cypress Traveo-II) S003485 Medium SWO trace doesn't work (Cypress CYT2B6) S003482 Medium MTB trace doesn't work (Cypress CYT2B6) S003313 Low Debug session initialization sometimes takes 10 or more seconds (Cypress Traveo-II CYT4BF). S001684 Low 1-bit parallel trace works unreliably, 4-bit parallel trace works fine (Cypress Traveo-II CYT2B7). ARM Cortex S003652 Medium Every 50th reset in average fails (Analog Devices ADuCM33x). S003429 Medium Access to RAM memory unreliable (Microsemi M2S050). Microchip S003957 Medium Synchronization lost error occurs in Analyzer recording if Recorder is configured to start On Trigger (Microchip SAMv7). S003909 Medium Debugging is not operational (Microchip SAMv7). S002215 Medium Program trace might contain errors when Profiler is configured to Trigger at 'Function execution' (Microchip SAMV7). Memory window shows as values were successfully written when writing to a disabled flash which is being mass erased before. After S000972 Low refreshing the window "manually", correct (erased) values are displayed (Microchip ATSAME54). List of known issues for winIDEA 9.21.9.0.118566 Texas Instruments S004114 Medium Write to any Flash location causes Flash programming or verification error (TI TMS570LS20216). S004083 Medium Parts of RAM unaccessible after Reset, but not after Download from winIDEA (TI RM57L843). S004006 Medium TMS570LS30336 download fails using iC5700. iC5000 works ok. (TI TMS570LS30336). S003738 Medium Every second download fails (TI MSP432). S001091 Medium FLASH write via memory window fails sometimes (TI MSP432E). Xilinx S000667 Low Programming bitstream to the FPGA doesn't work (Xilinx Zynq UltraScale+). S002567 Low Primary core goes to "RESET - DAP Access Failed" state after trace recording is stopped (Xilinx Zynq UltraScale+). Trace S004067 Medium Trace not working on certain RH850 devices. On-Chip Trace and Analyzer S004146 Medium Randomly Profiler Timeline & Statistics show certain OS Objects as duplicated. S003632 Medium Cannot profile OS objects that execute on other cores, rather than on the core where Analyzer is started. S002358 Low Trace window content is sometimes not refreshed properly after the trace recording is finished and uploaded. S001397 Low Default Coverage HTML export configuration does not contain any Coverage measurement data. AOM CAN/LIN and AOM ADIO S003386 Medium AOM (FNet) trace does not work on RH850 when Analyzer is in On-Chip operation mode. List of known issues for winIDEA 9.21.9.0.118566 AOM CAN/LIN and AOM ADIO S003297 Medium Time correlation between OS object trace and AOM ADIO trace is faulty when tracing OS objects from Infineon TC3xx SoC. S001908 Medium ADIO digital output trace sometimes doesn’t work if the signal was changed as a consequence of configured Trigger-Action in winIDEA. ADIO AIN configuration on which channel is recorded, is not applied right away. New debug session initialization is needed to apply the S001464 Low configuration. Digital output signals (DIO) values cannot be changed on configured outputs when ADIO is configured to record both digital inputs and S001136 Medium outputs. S001046 Medium ADIO AIN Voltage level triggers do not trigger every time when configured level is reached. S001043 Medium LIN recording enable/disable qualifiers are not taken into account when recording. S000694 Medium CAN-FD messages with 4 Mbps data baud rate are not recorded correctly by AOM CAN/LIN. S000579 Medium AOM ADIO SPI recording stops after 1024 clock cycles. S000084 Medium AOM ADIO analog input sampling rate is not always periodic. SDK S003867 Medium Path to SFR database changes if winIDEA instance is opened via SDK. S003455 Medium isystem.connect CDataController::batchAccess is not operational. S002736 Medium SDK CTraceController::applyTriggerWizard() does not produce same result as GUI Wizard (Renesas R-CAR M3-W). Graphical User Interface S003943 Low winIDEA incorrectly displays special characters with umlauts. S003710 Low Old winIDEA 9.17 icon is visible in certain scenarios in winIDEA 9.21 (Microsoft Windows taskbar, installation directory,...). S003178 Low Can't close autocomplete list in winIDEA editor by using keyboard only. List of known issues for winIDEA 9.21.9.0.118566 Graphical User Interface If the left arrow button of the horizontal scroll bar is pressed in the debug connection Progress window while the thumb is located in the S001109 Low leftmost position, the thumb relocates to the rightmost position. GDB Debug S000948 Low Breakpoint set in multiple threads that execute the same code, sometimes doesn’t stop in all spawned threads..