List of known issues for winIDEA 9.21.6.0.117591 Issue ID Severity Description General S001177 Medium winIDEA connection stops working after several hours of active debug session. S003966 Low Callstack is not displayed correctly if ARM Cortex application is compiled with DiabData compiler. S003658 Medium Go to... after download operation is not supported for secondary cores. S002844 Low winIDEA becomes unresponsive if CPU Options are changed when winIDEA terminal is connected to SoC and SoC is running. Infineon S003288 Medium winIDEA trace unreliable if interrupt hits on traced function exit (Infineon TC3xx). S003351 Medium Trace synchronization time error between CAN and AGBT trace gradually increases with recording length, (Infineon TC399XE). S003996 Medium Reset is not stable (Infineon TLE9844). S003803 Medium Flash Blank Check after Mass Erase does not work if secondary cores are running (Infineon TC298TP). S003792 Medium winIDEA cannot stop CPU core after external reset is triggered to SoC (Infineon TC298TF). S003330 Medium Start of trace session over AGBT trace protocol fails with faulty error message (Infineon TC277TE). iSYSTEM FBridge debug sync doesn't work when Infineon TC3xx is configured as a master workspace and used in conjunction with S003225 Medium Infineon AGBT Aurora Active Probe (Infineon TC3xx). Swapping tracing data from multiple cores, then in the next trace session from single core and in the next trace session again from S003174 Medium multiple cores, data are not traced from all configured cores (Infineon TC399XE). Correlation between AOM CAN trace and SoC data trace yields incorrect timeline ordering of the events (Infineon TriCore TC2xx and S000221 Low TC3xx). NXP S003548 Medium Programming very large files to the QSPI flash can fail (NXP LS1021A). List of known issues for winIDEA 9.21.6.0.117591 NXP S002344 Medium Recording longer application loop with MTB trace hangs winIDEA (NXP Kinetis MKM34Z256) S003993 Medium SWO data trace is not working with automatic Analyzer configuration (NXP i.MX7ULP). S003441 Medium Program trace works unreliably (NXP i.MX6UL). S002813 Low Flash Blank Check also checks 0x400-0x40F flash region, even though it should never be erased (NXP Kinetis KL03). S002797 Medium Debug reset executes unreliably (NXP i.MX RT0162). S002732 Medium Flash programming doesn't work (NXP Kinetis KL25Z). S001954 Medium Download sometimes fails (NXP i.MX RT1050). S000673 Low testIDEA fails to modify floating point registers (NXP LPC54114). ST S001771 Medium Stopping the CPU fails while it’s in Standby low power mode (ST STM32L053). S004000 Low Using vTAG memory access doesn't work correctly (ST SPC56EC74). S003945 Medium SWO trace doesn't work (ST STM32H723). S003900 Medium Mass erase slow on external QSPI, if SWD protocol is used to connect to SoC (ST STM32MP157). S003805 Medium winIDEA reset does not reset secondary cores (ST STA1385). S003713 Medium Synced Stop/Run of both cores via CTI does not work in some scenarios (ST STM32H755). S002738 Medium Cortex-M4 data trace from primary Cortex-A7 Analyzer session doesn't work (ST STM32MP157). S001331 Low Coverage does not work if 'All' is selected for Scope in the Coverage configuration (ST STA1385). List of known issues for winIDEA 9.21.6.0.117591 Renesas S001396 Low Timestamps of STM trace via HSSTP do not start from 0 on new trace recording (Renesas R-CAR H3v2). S003991 Low Establishing debug session isn't always successful if executed quickly via scripts (Renesas RH850/F1H). S003802 Medium Programming of Cypress S26Kx512 HyperFlash memory unstable (Renesas R-CAR V3H). S003680 Medium Any flash operation doesn't work (Renesas RH850/F1Kx). S003527 Low Attach to SoC after winIDEA Detach operation resets SoC (Renesas RH850/P1M). If winIDEA Analyzer is first run with enabled on-chip trace and then with disabled on-chip trace (Manual Trigger Configuration) in same S003202 Medium debug session, second run will still record on-chip trace (Renesas RH850). Trigger on both, data write and specific data value match, doesn't work on ARM CoreSight ETMv4 trace source component (Renesas R- S002901 Medium Car V3H). S002695 Medium Aurora trace stops working after a while if maximum Aurora trace clock is used (Renesas RH850/P1H-C). S001978 Low Floating point structure is not handled correctly in testIDEA (Renesas RZ/A1LU). S001485 Low Sometimes data trace is incomplete if iC6000 is connected to PC via USB (Renesas RH850/P1H-C). Cypress S001353 Medium Setting/clearing execution breakpoint doesn't work while in Standby low power mode (Cypress Traveo-II CYT2B7). S003824 Medium Application doesn't run on Run debug action (primary core) when started from Reset exception vector (Cypress CYT2B9). S003783 Medium If application is run already before programming the Flash, programming can fail (Cypress CY8C4245). S003662 Medium Data trace on secondary core doesn't work (Cypress Traveo-II) S003485 Medium SWO trace doesn't work (Cypress CYT2B6) S003482 Medium MTB trace doesn't work (Cypress CYT2B6) List of known issues for winIDEA 9.21.6.0.117591 Cypress S003313 Low Debug session initialization sometimes takes 10 or more seconds (Cypress Traveo-II CYT4BF). S001684 Low 1-bit parallel trace works unreliably, 4-bit parallel trace works fine (Cypress Traveo-II CYT2B7). ARM Cortex S004007 Medium ARM Cortex trace via trace buffer (ETF, ETB) doesn't work. S003652 Medium Every 50th reset in average fails (Analog Devices ADuCM33x). S003429 Medium Access to RAM memory unreliable (Microsemi M2S050). Microchip S003957 Medium Synchronization lost error occurs in Analyzer recording if Recorder is configured to start On Trigger (Microchip SAMv7). S003909 Medium Debug not operational (Microchip SAMv7). S002215 Medium Program trace might contain errors when Profiler is configured to Trigger at 'Function execution' (Microchip SAMV7). Memory window shows as values were successfully written when writing to a disabled flash which is being mass erased before. After S000972 Low refreshing the window "manually", correct (erased) values are displayed (Microchip ATSAME54). Texas Instruments S004006 Medium Download fails using iC5700. iC5000 works ok. (TI TMS570LS30336). S004003 Medium Data trace works unreliably (TI TMS570LS20216) S003756 Medium Hot attach doesn't work (TI RM48L950). S003738 Medium Every second download fails (TI MSP432). S001091 Medium FLASH write via memory window fails sometimes (TI MSP432E). List of known issues for winIDEA 9.21.6.0.117591 Xilinx S000667 Low Programming bitstream to the FPGA doesn't work (Xilinx Zynq UltraScale+). S002567 Low Primary core goes to "RESET - DAP Access Failed" state after trace recording is stopped (Xilinx Zynq UltraScale+). On-Chip Trace and Analyzer S003632 Medium Cannot profile OS objects that execute on other cores, rather than on the core where Analyzer is started. S003947 Low winIDEA Analyzer coverage doesn't ignore unreachable code in statistics, even if configured to do so. S002358 Low Trace window content is sometimes not refreshed properly after the trace recording is finished and uploaded. S001397 Low Default Coverage HTML export configuration does not contain any Coverage measurement data. AOM CAN/LIN and AOM ADIO S003351 Medium Trace synchronization time error between CAN and AGBT trace gradually increases with recording length, (Infineon TC399XE). When tracing on-chip trace and AOM CAN/LIN network with Analyzer, there is a delay at start of the recording roughly the same length as S004012 Low current debug session (Infineon TriCore). S003880 Medium Not all CAN messages are recorded when analyzing CAN network with AOM CAN/LIN. S003386 Medium AOM (FNet) trace does not work on RH850 when Analyzer is in On-Chip operation mode. S003297 Medium Time correlation between OS object trace and AOM ADIO trace is faulty when tracing OS objects from Infineon TC3xx SoC. S001908 Medium ADIO digital output trace sometimes doesn’t work if the signal was changed as a consequence of configured Trigger-Action in winIDEA. ADIO AIN configuration on which channel is recorded, is not applied right away. New debug session initialization is needed to apply the S001464 Low configuration. Digital output signals (DIO) values cannot be changed on configured outputs when ADIO is configured to record both digital inputs and S001136 Medium outputs. S001046 Medium ADIO AIN Voltage level triggers do not trigger every time when configured level is reached. List of known issues for winIDEA 9.21.6.0.117591 AOM CAN/LIN and AOM ADIO S001043 Medium LIN recording enable/disable qualifiers are not taken into account when recording. S000694 Medium CAN-FD messages with 4 Mbps data baud rate are not recorded correctly by AOM CAN/LIN. S000579 Medium AOM ADIO SPI recording stops after 1024 clock cycles. S000084 Medium AOM ADIO analog input sampling rate is not always periodic. SDK S003867 Medium Path to SFR database changes if winIDEA instance is opened via SDK. S003455 Medium isystem.connect CDataController::batchAccess is not operational. S002736 Medium SDK CTraceController::applyTriggerWizard() does not produce same result as GUI Wizard (Renesas R-CAR M3-W). Graphical User Interface S003943 Low winIDEA incorrectly displays characters with umlauts. Old 9.17 winIDEA icon can still be spotted in certain scenarios on 9.21 winIDEA installation (Microsoft Windows taskbar, installation S003710 Low directory,...). S003178 Low Can't close autocomplete list in winIDEA editor by using keyboard only. If the left arrow button of the horizontal scroll bar is pressed in the debug connection Progress window while the thumb is located in the S001109 Low leftmost position, the thumb relocates to the rightmost position. GDB Debug S000948 Low Breakpoint set in multiple threads that execute the same code, sometimes doesn’t stop in all spawned threads..