US MSRP PRICE BOOK Effective: June 1, 2021 HEARTH | 2021 US MSRP PRICE BOOK Effective: June 1, 2021 HEARTH DIVISION Please export pricebook spreadsheet from Napoleon's AD-PB-MSRP-HEARTH-NAPUS-21B dealer portal for most current content and prices. TABLE OF CONTENTS 04 81 FIREPLACES GAS LOG SETS Direct Vent Gas Fireplaces Wood Fireplaces Direct Vent ™ 4 Luxuria™ Series 62 High Country 8000 81 Fiberglow™ Series (LVX38, LVX50, LVX62, LVX74) (NZ8000) (GL18, GL24, GL30) ™ 6 Vector™ Series 63 High Country 6000 (LV38, LV50, LV62, LV74) (NZ6000 Vent Free ™ ™ ™ 65 High Country 5000 82 Fiberglow Series 8 Acies Series (GVFL18, GVFL24, GVFL30) (L38, L50) (NZ5000) ™ 10 Ascent™ Linear Series 66 High Country 3000 (BL36, BL46) (NZ3000) 13 Elevation™ X Series 84 (EX36, EX42) ™ STOVES 16 NEW Elevation Series (E36, E42) 69 Direct Vent Gas ™ INSERTS ™ 20 Altitude X Series 84 Havelock Series (AX36, AX42) (GDS50) ™ Direct Vent Gas 24 STARfire Series ™ ™ 85 Haliburton Series (HDX52) 69 Oakville Series (GDS28) (GDI3N, GDI3NE, GDIG3N, 28 High Definition Series GDIX3N, GDIX4N) 86 Knightsbridge™ Series (HD81) 73 Roxbury™ Series (GDS60) ™ 32 NEW Ascent Deep Series (GI3600) 87 Castlemore™ Series (D42, DX42) 76 Inspiration™ Series (GDS26) ™ 36 Ascent X Series (GDIZC) 88 Bayfield™ Series (GX70, GX42, GX36, (GDS25) NEW BX36, NEW BX42) Wood ™ ™ 89 Arlington Series 44 Ascent Series 79 NEW S Series (GDS20) (B30, B36, B42, B46) (S20i, S25i) ™ 46 Ascent Multi-View Series 80 Oakdale™ Series Wood (BHD4) (EPI3C, EPI3T, EPI3TN) 91 NEW S Series 51 Vertical Series (S20, S25) (GD82, GT8, GD19) 57 Torch Series (GVFT8) 59 Grandville™ Series (GVF36, GVF42) 2 2021 US HEARTH PRICE BOOK 93 105 117 OUTDOOR ELECTRICS TIMBERWOLF® Outdoor Fireplaces Built-in Wood Stoves 93 Riverside™ Series 105 CLEARion™ Elite Series 117 Timberwolf® Economizer™ Series (GSS42CF) 106 Trivista™ Series (2100-1, 2200-1) ® ™ 95 Patioflame Series 107 Element Series Wood Inserts (GPFL48MHP, GPFL48, GPFS60, GPFR60) ™ 108 NEW Cineview Series 118 Timberwolf® Economizer™ Series ™ 109 Ascent Electric Series (EPI22-1) Wall Hanging 98 110 NEW Stylus™ Series VENTING 111 Alluravision™ Deep Series ™ 120 98 Direct Vent Flex 112 Alluravision Slimline Series 120 Product Return Policy ™ 100 Direct Vent Rigid 113 Entice Series ™ 101 Gas Inserts 114 Allure Vertical Series 102 Gas Stoves Electric Fireplace 102 Power Vent Mantel Packages 121 121 Minimum Advertised Price 102 Stove Pipe 115 Decor Series 104 NEW Ducted Heat Management (MAP) Policy Electric Log Sets 116 Woodland™ Series Prices listed in US dollars. Napoleon strives for accuracy and the information in this Price Book reflects the information available at the time of publication. Occasionally, product specifications are updated or prices change without notice due to circumstances beyond our control. A correction notice will be issued if inaccuracies occur. The most current version of the Price Book can always be accessed through the dealer portal on my.napoleon.com. Wolf Steel Ltd reserves the right to makes changes to prices and products without notice. 2021 US HEARTH PRICE BOOK 3 DIRECT VENT GAS FIREPLACES Luxuria™ Series Venting Top 5" / 8" Single Sided LVX38 Single Sided LVX50 Single Sided LVX62 Single Sided LVX74 See Through LVX38 See Through LVX50 See Through LVX62 See Through LVX74 FEATURES › From 32,000 BTU's to 50,000 BTU's › Flame/Heat Adjustment › President's Limited Lifetime Warranty › Easy Access Air Control › Patented Dynamic Heat Control™ › MIRRO-FLAME™ Porcelain Reflective Radiant Panels (Included) › ProFlame II and eFire Controller › Battery Back-Up Control System › Flame/Heat Adjustment › Firestop / Vent Shield › Ember Bed Featuring Multi-Colored LED Lights › ACS Switch Included › Divinity™ Flame Pattern › Stainless Steel Flex Connector STEP 1 - LUXURIA™ SERIES FIREPLACE MODELS (MANDATORY. CHOOSE BASE UNIT.) Product Description LVX38 LVX50 LVX62 LVX74 $5,999 $7,399 $10,599 $12,199 Single Sided, Direct Vent, Electronic Ignition - Natural Gas (LP kit sold separately) LVX38NX-1 LVX50NX-1 LVX62NX-1 LVX74NX-1 $7,199 $8,499 $11,999 $13,799 See Through, Direct Vent, Electronic Ignition - Natural Gas (LP kit sold separately) LVX38N2X-1 LVX50N2X-1 LVX62N2X-1 LVX74N2X-1 $12,199 Single Sided, Direct Vent, Electronic Ignition - Propane N/A N/A N/A LVX74PX $13,799 See Through, Direct Vent, Electronic Ignition - Propane N/A N/A N/A LVX74P2X 4 2021 US HEARTH PRICE BOOK DIRECT VENT GAS FIREPLACES Luxuria™ Series Venting Top 5" / 8" STEP 2 - MEDIA KITS AND GLASS KITS (MANDATORY. CHOOSE ONE TO COMPLETE UNIT.) Product Description LVX38 LVX50 LVX62 LVX74 $275 $275 $380 $380 Beach Fire Kit (Recommended with Shore Fire Kit) BFKM BFKM BFKXL BFKXL $370 $435 $565 $710 Birch Log Kit (Recommended with Shore Fire Kit) BLKS BLKM BLKL BLKXL $360 $440 $570 $710 Contemporary Log Kit (Recommended with Shore Fire Kit) CLKS CLKM CLKL CLKXL $170 $240 $265 $320 Mineral Rock Kit (Recommended with Shore Fire Kit) MRKS MRKM MRKL MRKXL $160 $160 $180 $180 Shore Fire Kit, Mixture Of Rocks, Sand, Vermiculite & Glass SFKM SFKM SFKL SFKL $105 $105 $105 $105 Amber Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBA MKBA MKBA MKBA $105 $105 $105 $105 Black Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBK MKBK MKBK MKBK $105 $105 $105 $105 Blue Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBB MKBB MKBB MKBB $105 $105 $105 $105 Clear Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBC MKBC MKBC MKBC $105 $105 $105 $105 Topaz Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBT MKBT MKBT MKBT STEP 3 - ADDITIONAL PARTS AND ACCESSORIES (OPTIONAL) Product Description LVX38 LVX50 LVX62 LVX74 $680 $680 $680 $680 Nickel Stix Designer Fire Art (Recommended 2 Kits for 62/74) LDNS LDNS LDNS LDNS $285 $285 $570 $570 Wrought Iron Globes - Naturally Rusted WIGM WIGM WIGL WIGL $100 $145 $155 Conversion Kit - Natural Gas To Propane N/A W175-0650 W175-0652 W175-0654 $2,300 $2,545 $2,755 $3,010 Indoor/Outdoor Kit (Require 6-8 weeks lead time) IOL38K IOL50K IOL62K IOL74K STEP 4 - LINEAR SERIES ADDITIONAL OPTIONS (GO TO PAGE 11) STEP 5 - 5"/8" DIRECT VENT FLEX VENT COMPONENTS (GO TO PAGE 99) Notes: These units are suitable for Power Vent Adaptor Kit (go to page 102) Round wall vent terminal is required - Please order GD422R-2 LVX62 & LVX74 require 4 weeks lead time 2021 US HEARTH PRICE BOOK 5 DIRECT VENT GAS FIREPLACES Vector™ Series Venting Top 5" / 8" Single Sided LV38 Single Sided LV50 Single Sided LV62 Single Sided LV74 See Through LV38 See Through LV50 See Through LV62 See Through LV74 FEATURES › From 30,000 BTU's to 48,000 BTU's › Easy Access Air Control › Heat Radiating Ceramic Glass › ProFlame II and eFire Controller › Black Premium Safety Barrier › Tube Style Burner with Flame/Heat Adjustment › Multi-Color LED Lighting and Accent Lighting › MIRRO-FLAME™ Porcelain Reflective Radiant Panels included › Battery Back-Up Control System › Firestop / Vent Shield › Stainless Steel Flex Connector › ACS Switch Included STEP 1 - VECTOR™ SERIES FIREPLACE MODELS (MANDATORY. CHOOSE BASE UNIT.) Product Description LV38 LV50 LV62 LV74 $3,799 $4,099 $6,699 $8,249 Single Sided, Direct Vent, Electronic Ignition - Natural Gas (LP kit sold separately) LV38N-1 LV50N-2 LV62N LV74N $4,649 $5,349 $7,949 $10,299 See Through, Direct Vent, Electronic Ignition - Natural Gas (LP kit sold separately) LV38N2-1 LV50N2-2 LV62N2 LV74N2 $8,249 Single Sided, Direct Vent, Electronic Ignition - Propane N/A N/A N/A LV74P $10,299 See Through, Direct Vent, Electronic Ignition - Propane N/A N/A N/A LV74P2 STEP 2 - MEDIA KITS AND GLASS KITS (MANDATORY. CHOOSE ONE TO COMPLETE UNIT.) Product Description LV38 LV50 LV62 LV74 $275 $275 $380 $380 Beach Fire Kit (Recommended with Shore Fire Kit) BFKM BFKM BFKXL BFKXL $370 $435 $565 $710 Birch Log Kit (Recommended with Shore Fire Kit) BLKS BLKM BLKL BLKXL 6 2021 US HEARTH PRICE BOOK DIRECT VENT GAS FIREPLACES Vector™ Series Venting Top 5" / 8" STEP 2 - MEDIA KITS AND GLASS KITS CONTINUED (MANDATORY. CHOOSE ONE TO COMPLETE UNIT.) Product Description LV38 LV50 LV62 LV74 $360 $440 $570 $710 Contemporary Log Kit (Recommended with Shore Fire Kit) CLKS CLKM CLKL CLKXL $170 $240 $265 $320 Mineral Rock Kit (Recommended with Shore Fire Kit) MRKS MRKM MRKL MRKXL $160 $160 $180 $180 Shore Fire Kit, Mixture Of Rocks, Sand, Vermiculite & Glass SFKM SFKM SFKL SFKL $105 $105 $105 $105 Amber Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBA MKBA MKBA MKBA $105 $105 $105 $105 Black Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBK MKBK MKBK MKBK $105 $105 $105 $105 Blue Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBB MKBB MKBB MKBB $105 $105 $105 $105 Clear Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBC MKBC MKBC MKBC $105 $105 $105 $105 Topaz Glass Beads Media Kit (Recommended 2 Kits for 38/50, 3 Kits for 62/74) MKBT MKBT MKBT MKBT STEP 3 - ADDITIONAL PARTS AND ACCESSORIES (OPTIONAL) Product Description LV38 LV50 LV62 LV74 $680 $680 $680 $680 Nickel Stix Designer Fire Art (Recommended 2 Kits for 62/74) LDNS LDNS LDNS LDNS $285 $285 $570 $570 Wrought Iron Globes - Naturally Rusted WIGM WIGM WIGL WIGL $995 $1,230 Brushed Stainless Steel Surround with Premium Safety Barrier N/A N/A SLF38SS SLF50SS $670 $805 Classic Black Surround with Premium Safety Barrier N/A N/A SLF38K SLF50K $940 $1,165 $1,230 $1,325 Brushed Stainless Steel Premium Safety Barrier PSB38SS PSB50SS PSB62SS PSB74SS $140 $140 $140 $140 End Panel Kit (Single Sided
Recommended publications
  • Consider Installing a Condensing Economizer, Energy Tips
    ADVANCED MANUFACTURING OFFICE Energy Tips: STEAM Steam Tip Sheet #26A Consider Installing a Condensing Economizer Suggested Actions The key to a successful waste heat recovery project is optimizing the use of the recovered energy. By installing a condensing economizer, companies can im- ■■ Determine your boiler capacity, prove overall heat recovery and steam system efficiency by up to 10%. Many average steam production, boiler applications can benefit from this additional heat recovery, such as district combustion efficiency, stack gas heating systems, wallboard production facilities, greenhouses, food processing temperature, annual hours of plants, pulp and paper mills, textile plants, and hospitals. Condensing economiz- operation, and annual fuel ers require site-specific engineering and design, and a thorough understanding of consumption. the effect they will have on the existing steam system and water chemistry. ■■ Identify in-plant uses for heated Use this tip sheet and its companion, Considerations When Selecting a water, such as boiler makeup Condensing Economizer, to learn about these efficiency improvements. water heating, preheating, or A conventional feedwater economizer reduces steam boiler fuel requirements domestic hot water or process by transferring heat from the flue gas to the boiler feedwater. For natural gas-fired water heating requirements. boilers, the lowest temperature to which flue gas can be cooled is about 250°F ■■ Determine the thermal to prevent condensation and possible stack or stack liner corrosion. requirements that can be met The condensing economizer improves waste heat recovery by cooling the flue through installation of a gas below its dew point, which is about 135°F for products of combustion of condensing economizer.
    [Show full text]
  • Use Feedwater Economizers for Waste Heat Recovery, Energy Tips
    ADVANCED MANUFACTURING PROGRAM Energy Tips: STEAM Steam Tip Sheet #3 Use Feedwater Economizers for Waste Heat Recovery Suggested Actions ■■ Determine the stack temperature A feedwater economizer reduces steam boiler fuel requirements by transferring after the boiler has been tuned heat from the flue gas to incoming feedwater. Boiler flue gases are often to manufacturer’s specifications. rejected to the stack at temperatures more than 100°F to 150°F higher than The boiler should be operating the temperature of the generated steam. Generally, boiler efficiency can at close-to-optimum excess be increased by 1% for every 40°F reduction in flue gas temperature. By air levels with all heat transfer recovering waste heat, an economizer can often reduce fuel requirements by 5% surfaces clean. to 10% and pay for itself in less than 2 years. The table provides examples of ■■ Determine the minimum the potential for heat recovery. temperature to which stack gases Recoverable Heat from Boiler Flue Gases can be cooled subject to criteria such as dew point, cold-end Recoverable Heat, MMBtu/hr corrosion, and economic heat Initial Stack Gas transfer surface. (See Exhaust Temperature, °F Boiler Thermal Output, MMBtu/hr Gas Temperature Limits.) 25 50 100 200 ■■ Study the cost-effectiveness of installing a feedwater economizer 400 1.3 2.6 5.3 10.6 or air preheater in your boiler. 500 2.3 4.6 9.2 18.4 600 3.3 6.5 13.0 26.1 Based on natural gas fuel, 15% excess air, and a final stack temperature of 250˚F. Example An 80% efficient boiler generates 45,000 pounds per hour (lb/hr) of 150-pounds-per-square-inch-gauge (psig) steam by burning natural gas.
    [Show full text]
  • Energy and Exergy Analysis of Data Center Economizer Systems
    San Jose State University SJSU ScholarWorks Master's Theses Master's Theses and Graduate Research Spring 2011 Energy and Exergy Analysis of Data Center Economizer Systems Michael Elery Meakins San Jose State University Follow this and additional works at: https://scholarworks.sjsu.edu/etd_theses Recommended Citation Meakins, Michael Elery, "Energy and Exergy Analysis of Data Center Economizer Systems" (2011). Master's Theses. 3944. DOI: https://doi.org/10.31979/etd.bf7d-khxd https://scholarworks.sjsu.edu/etd_theses/3944 This Thesis is brought to you for free and open access by the Master's Theses and Graduate Research at SJSU ScholarWorks. It has been accepted for inclusion in Master's Theses by an authorized administrator of SJSU ScholarWorks. For more information, please contact [email protected]. ENERGY AND EXERGY ANALYSIS OF DATA CENTER ECONOMIZER SYSTEMS A Thesis Presented to The Faculty of the Department of Mechanical and Aerospace Engineering San José State University In Partial Fulfillment of the Requirements for the Degree Master of Science By Michael E. Meakins May 2011 © 2011 Michael E. Meakins ALL RIGHTS RESERVED The Designated Thesis Committee Approves the Thesis Titled ENERGY AND EXERGY ANALYSIS OF DATA CENTER ECONOMIZER SYSTEMS by Michael E. Meakins APPROVED FOR THE DEPARTMENT OF MECHANICAL AND AEROSPACE ENGINEERING SAN JOSÉ STATE UNIVERSITY May 2011 Dr. Nicole Okamoto Department of Mechanical and Aerospace Engineering Dr. Jinny Rhee Department of Mechanical and Aerospace Engineering Mr. Cullen Bash Hewlett Packard Labs ABSTRACT ENERGY AND EXERGY ANALYSIS OF DATA CENTER ECONOMIZER SYSTEMS By Michael E. Meakins Electrical consumption for data centers is on the rise as more and more of them are being built.
    [Show full text]
  • Thermal Optimization of Solar Biomass Hybrid Cogeneration Plants
    Journal of Scientific & Industrial Research Vol. 65 April 2006, pp. 355-363 Thermal optimization of solar biomass hybrid cogeneration plants Anuradha Mishra 1, M N Chakravarty 2 and N D Kaushika 2, * 1IEC College of Engineering and Technology, Greater Noida 2School of Research and Development, Bharati Vidyapeeth College of Engineering, Paschim Vihar, New Delhi Received 10 February 2005; accepted 25 January 2006 Thermal optimization and performance matching of subsystems in solar biomass hybrid plant are investigated. The plant incorporates solar collector field, multiple fuel boiler, steam turbine, deaerator and economizer units. The solar field consists of line focus parabolic trough collectors. The thermal model is used for comparative study of various variations of parabolic trough collectors; LS3, Euro Trough (ET) and Duke solar excel over others. The matching of the output heat Qu and the temperature to the feed water conditions indicate that ET is the most suitable for the application; its inlet temperature requirement also matches the energy balance of the deaerator. Keywords : Biogas, Cogeneration, Hybrid power plant, Parabolic trough collector Introduction Cogeneration Plant Configuration India produces abundant quantities of agro residues A solar biomass hybrid plant would incorporate (rice husk, coffee husk, cashew shells, groundnut solar collector field, multiple fuel boiler, steam shells) and wastes (distillery waste). Co-generation of turbine, deaerator and economizer units (Fig. 1). The process heat and power is an important energy saving solar field consists of concentrating collectors. Three approach. It is particularly suitable for paper, solar thermal collector technologies (parabolic trough, chemicals, textiles, food and petroleum refining parabolic dish and solar tower) have reached the stage industries.
    [Show full text]
  • Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction May 2017
    PNNL-25985 Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction May 2017 N Fernandez Y Xie S Katipamula M Zhao W Wang C Corbin Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 PNNL-25985 Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction N Fernandez Y Xie S Katipamula M Zhao W Wang C Corbin May 2017 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Pacific Northwest National Laboratory Richland, Washington 99352 Summary Background Commercial buildings in the United States consume approximately 18 quadrillion British thermal units (quads) of primary energy annually (EIA 2016). Inadequate building operations leads to preventable excess energy consumption along with failure to maintain acceptable occupant comfort. Studies have shown that as much as 30% of building energy consumption can be eliminated through more accurate sensing, more effective use of existing controls, and deployment of advanced controls (Fernandez et al. 2012; Fernandez et al. 2014; AEDG 2008). Studies also have shown that 10% to 20% of the commercial building peak load can be temporarily managed or curtailed to provide grid services (Kiliccote et al. 2016; Piette et al. 2007). Although many studies have indicated significant potential for energy savings in commercial buildings by deploying sensors and controls, very few have documented the actual measured savings (Mills 2009; Katipamula and Brambley 2008). Furthermore, previous studies only provided savings at the whole-building level (Mills 2009), making it difficult to assess the savings potential of each individual measure deployed. Purpose Pacific Northwest National Laboratory (PNNL) conducted this study to systematically estimate and document the potential energy savings from Re-tuning™ commercial buildings using the U.S.
    [Show full text]
  • Economizers in Chiller Systems
    Ekaterina Vinogradova T662KA ECONOMIZERS IN CHILLER SYSTEMS Bachelor’s Thesis Building Services Engineering November 2012 DESCRIPTION Date of the bachelor's thesis 17.12.12 Author(s) Degree programme and option Ekaterina Vinogradova Double Degree Programme in Building Services Engineering Name of the bachelor's thesis Economizers in Chiller Systems Abstract There are many buildings that have cooling demands for different purposes. They can be hospitals, administrative and office buildings, shopping centers, data centers and also industrial buildings. Cooling of processes and products, cool rooms, ice halls, and air-conditioning systems require chiller system application. Chiller system is usually the substantial part of energy consumption of the build- ing. That’s why different ways of increasing of the chiller systems efficiency began to be used more often. Due to the widespread use a lot of schemes to optimize and improve the effectiveness of chiller sys- tems have been developed. One possibility is the installation of an additional low-cost equipment like the economizer systems. They may be applied in the refrigeration cycle of the chiller or in the rest chiller system. In the theoretical part of the thesis measures and methods of the chiller systems efficiency increasing and different types of economizers were described. Influencing on the economizers efficiency factors were noted. Study case contains the simulation of the office building in different modes with IDA Indoor Climate and Energy software. Some results of the simulations are presented in the tables. The benefit from the economizer operation is calculated as compared with traditional chiller system. Also influence of the economizer set-point temperature on its benefits was evaluated.
    [Show full text]
  • Alfa Laval VHE Economizer
    305021_PFT00177EN:252873_VHE Economizer 02/09/10 9:17 Side 1 VHE Economizer For deodorization and physical refining of fats and oils The VHE Economizer Application the tube side and flows through a multipass tube system This high-performance heat exchanger is specially designed until it reaches the outlet connection at the other end. to recover heat by cooling the deodorized edible fats and oils in deodorization and physical refining plants and – at the Counter-current flow between the incoming oil and same time – heating the incoming oil. This cooling takes deodorized oil is maintained by a special design of the place under vacuum and sparging steam conditions. tubes and baffles on the shell side. The VHE Economizer is part of the Alfa Laval deodorization To avoid cross-contamination and provide fast draining during concept, but is also available as a retrofit component for stock changes, the heat exchanger is fitted with a special installation in other deodorization systems – irrespective of fast-drain valve arrangement on both sides. origin. Design features Operating principles The VHE Economizer is designed to achieve a high level of The hot deodorized oil enters the VHE Economizer at one heat recovery by cooling the deodorized oil under vacuum end of the shell side, which is under vacuum, and flows and sparge steam conditions, while heating the incoming oil. through a special system of channels and baffles until it Under full sparge steam conditions, this gradual cooling reaches the outlet connection at the other end. It is then means the oil is treated gently and the quality improves.
    [Show full text]
  • "Free" Cooling Using Water Economizers
    engineers newsletter volume 37–3 • providing insights for today’s hvac system designer "free" cooling using Standard 90.1 requirements Water Economizers The following sections of the Standard 90.1 prescriptive path are relevant for water economizers.[4] from the editor … Why economize? In past newsletters, we addressed the ability to accomplish "free" cooling by There are times of the year when a Section 6.5.1 Economizers. "Each artfully rearranging traditional cooling cooling system…" over the size equipment [1] and other ways to achieve system can use outdoor conditions to byproduct cooling virtually for free.[2] cool the building or process using the thresholds shown below "that has a fan We’ve also provided newsletters that standard cooling components to shall include either an air or water discussed air economizers and energy distribute its cooling effect. economizer." There are nine exceptions: code requirements.[3] small individual fan cooling units, In this EN, Susanna Hanson (Trane The most prevalent technique is an air spaces humidified above 35°F (2ºC) applications engineer) focuses on the economizer. When the temperature, or dew point for processes, systems with traditional methods of water-side enthalpy, of the outdoor air is low, condenser heat recovery, some economizing and associated energy code requirements. cooler outdoor air is used to reduce the residential applications, and systems temperature (or enthalpy) of air entering with minimal hours or cooling loads. the cooling coil. This can reduce or There is also an option to use higher eliminate mechanical cooling for much Let’s start with some definitions. efficiency equipment in lieu of an of the year in many climates.
    [Show full text]
  • A Series Arrangement of Economizer – Evaporator Flat Solar Collectors As an Enhancement for Solar Steam Generator
    Journal of Ecological Engineering Journal of Ecological Engineering 2021, 22(5), 121–128 Received: 2021.02.16 https://doi.org/10.12911/22998993/135874 Accepted: 2021.04.14 ISSN 2299–8993, License CC-BY 4.0 Published: 2021.05.01 A Series Arrangement of Economizer – Evaporator Flat Solar Collectors as an Enhancement for Solar Steam Generator Mahmmod Al-Saiydee1*, Ali Alhamadani2, Waleed Allamy1 1 Engineering Technical College in Maysan, Electromechanical Engineering Department, Southern Technical University, Basra, Iraq 2 Engineering College, Mechanical Engineering Department, Wasit University, Wasit, Kut, Iraq * Corresponding author’s email: [email protected] ABSTRACT Two flat solar collectors were designed and connected in series in order to achieve a moderately high outlet temper- ature. This high temperature is to be considered as the inlet temperature to a concentrated collector which is able of generating superheated steam. The first collector plays a role as a preheater; hence, it is called an economizer and the other plays a role as a temperature riser, thus it is called an evaporator. The economizer is a closed steel tank equipped with internal baffles distributed equally to ensure perfect circulation of water inside the tank. However, the evaporator consists of an array of vertical pipes connected to two horizontal manifolds (risers and headers) and bonded to a steel sheet. Both collectors are coated black with a granulated carbon layer and exposed to sun through two glass layers. Two water flow rates were applied at the evaporator 100 L/hr and 200 L/hr. The result shows that a maximum outlet temperature of 73°C and a maximum efficiency of 82% at the beginning of the experiment and 55% by the end of experiment were achieved when the flow rate was 100 L/hr.
    [Show full text]
  • Technology Review CSU DECARBONIZATION FRAMEWORK TASK 4: TECHNOLOGY REVIEW TABLE of CONTENTS SECTION 4.1: Introduction
    CSU Office of the Chancellor CSU Decarbonization Framework: Technology Review CSU DECARBONIZATION FRAMEWORK TASK 4: TECHNOLOGY REVIEW TABLE OF CONTENTS SECTION 4.1: Introduction ........................................................................................................................ 3 SECTION 4.2: Space Heating Technologies .............................................................................................. 4 4.2.1 Heat Pump Overview .................................................................................................................. 6 4.2.2 Hydronic Heat Pumps ................................................................................................................. 7 Air-to-Water Heat Pump (AWHP)............................................................................................................ 7 Water-to-Water Heat Pump (WWHP) .................................................................................................... 13 4.2.3 Non-Hydronic Heat Pumps ....................................................................................................... 21 Water source heat pump (WSHP)......................................................................................................... 21 Air-to-Air Heat Pump ............................................................................................................................ 25 Variable Refrigerant Flow (VRF/VRV) .................................................................................................... 27
    [Show full text]
  • Solar Energy As an Alternative Source in Boiler Economizers
    19th International Conference on Renewable Energies and Power Quality (ICREPQ’21) Almeria (Spain), 28th to 30th July 2021 Renewable Energy and Power Quality Journal (RE&PQJ) ISSN 2172-038 X, Volume No.19, September 2021 Solar Energy as an alternative source in boiler economizers A. Daniel Pereira de Oliveira1, B. Aylton José Alves1, C. Bárbara Morais Arantes2 1. Pós-Graduação em Tecnologia de Processos Sustentáveis, Instituto Federal de Goiás, Goiânia, Brasil, phone: +55062981231123, e-mail: A. [email protected], B. [email protected] 2Pós-Graduação em Ciências da Saúde, Universidade Federal de Goiás, Goiânia, Brasil, phone: +55062981231123, e-mail: C. [email protected] Abstract. This study sought to analyze the viability of the use of solar energy, for the operation in boiler economizers, in the Despite the market importance of the coal-fired industrial replacement of the thermal energy of the exhaust gases. The units, it is worth noting that there is a high environmental experiment was divided in two steps: analysis of the boiler yield cost, among which can be highlight [5]. with different feed water temperatures and addition of the solar field to the initial set. For the modeling of the economizer-boiler set, the software used was Engineering Equation Solver (Software Process of cleaning flue gases with heavy water, which can F-Chart, Wisconsin, USA). The technology chosen for the second contaminate as water basins and consequently affect the stage was the high-pressure vacuum solar collector, installed at environmental balance; With the burning of coal there are the inlet of the feed water heater.
    [Show full text]
  • Economizer Logic
    Commercial Rooftop HVAC Energy Savings Research Program Bench Test Report June 2008 Prepared by: Mark Cherniack – Senior Program Manager Howard Reichmuth PE – Senior Engineer Prepared for: Northwest Power and Conservation Council 851 SW Sixth Avenue, Suite 11100 Portland, Oregon 97204 (503) 222-5161 Acknowledgements Acknowledgements The design and set up of the testing chamber, testing of the components/systems, and initial data assessment was completed by David Robison, P.E., Stellar Processes, Bob Davis, Ecotope and Dennis Landwehr, P.E. under subcontract to New Buildings Institute (NBI). NBI staff is responsible for the final report and conclusions. The following organizations provided funding to make this phase of the ongoing research possible. They responded to an invitation to participate in this opportunity to further the potential for cooperative research partnerships among interested participants nationwide on small commercial HVAC system issues. Their contributions are much appreciated. From the Pacific Northwest through the Northwest Power and Conservation Council Avista Utilities Bonneville Power Administration Eugene (OR) Water and Electric Board Energy Trust of Oregon Idaho Power PacifiCorp (non-Energy Trust area) Puget Sound Energy Snohomish Public Utility District From the Northeast Cape Light Compact (through Northeast Energy Efficiency Partnership-NEEP) Connecticut Light & Power (NEEP) Long Island Power Authority (NEEP) The United Illuminating Company (NEEP) Western Massachusetts Electric (NEEP) Efficiency Maine Efficiency Vermont National Grid New York State Energy Research and Development Authority NSTAR The Project Team also acknowledges the responsiveness of Honeywell Product Manager Adrienne Thomle and her engineering staff for making recommendations that strengthened the research, as well as responding with new product designs that will allow economizers to fully function as intended in saving energy.