Analysis of Thin Film Piezoelectric Microaccelerometer Using

Total Page:16

File Type:pdf, Size:1020Kb

Analysis of Thin Film Piezoelectric Microaccelerometer Using Sensors and Actuators A 113 (2004) 1–11 Analysis of thin film piezoelectric microaccelerometer using analytical and finite element modeling Qing-Ming Wang∗, Zhaochun Yang, Fang Li, Patrick Smolinski Department of Mechanical Engineering, University of Pittsburgh, 639 Benedum Hall, Pittsburgh, PA 15261, USA Received 5 November 2003; received in revised form 11 February 2004; accepted 28 February 2004 Available online 24 May 2004 Abstract Microaccelerometers using piezoelectric lead zirconate titanate (PZT) thin films have attracted much interest due to their simple structure and potentially high sensitivity. In this paper, we present a theoretical model for a microaccelerometer with four suspended flexural PZT-on-silicon beams and a central proof mass configuration. The model takes into account the effect of device geometry and elastic properties of the piezoelectric film, and agrees well with the results obtained by the finite element analysis. This study shows that the accelerometer sensitivity decreases with increases in the beam width, in the thickness of the bilayer beams, and in the elastic modulus of the mechanical microstructure. Increases in the beam length increase sensitivity. For a fixed beam thickness, a maximum sensitivity exists for appropriate PZT/Si thickness ratio. In addition, it is found that with appropriate geometrical dimensions, both high sensitivity and broad frequency bandwidth can be achieved. The calculation of the stress distribution in the suspended PZT/Si beam structure when the device is subjected to large vibrational acceleration indicates that the thin film microaccelerometer can stand extremely large g conditions with very good mechanical reliability. In the dynamic analysis, it is found that both analytical model and finite element modeling give very close results of the resonance frequency of the device. The results of this study can be readily applied to on-chip piezoelectric microaccelerometer design and its structural optimization. © 2004 Elsevier B.V. All rights reserved. Keywords: Piezoelectric accelerometer; MEMS; Sensitivity; Lead zirconate titanate (PZT) thin film 1. Introduction piezoelectric accelerometers have been widely used in con- dition monitoring systems to measure machinery vibration. Piezoelectric accelerometers use the direct piezoelectric Recently, microaccelerometers using piezoelectric thin film effect of a piezoelectric ceramic, crystal or thin film to gen- have drawn much research interest due to the miniaturiza- erate an electrical charge output that is proportional to ap- tion trend of electronic devices, their low cost and their suit- plied acceleration [1–3]. In an accelerometer, the stress in ability for batch manufacturing [4–7]. Research has focused the device occurs as a result of the seismic mass vibration on the thin film accelerometer design [8], fabrication [9], imposing a force on the piezoelectric materials. The total device’s measurement capabilities [10] and structural anal- amount of accumulated charge is proportional to the applied ysis and modeling to increase the sensitivity of the devices. force and the applied force is proportional to acceleration. For example, Eichner et al. [11] have measured the me- The electrodes on the piezoelectric device collect the charge chanical vibration and electromechanical sensitivity of mi- that can be transmitted to a signal conditioner that is remote cromachined accelerometer devices with four piezoelectric or built into the accelerometer. Once the charge is condi- read-out capacitors; Ries and Smith [12] have used the finite tioned, the signal is available for display, recording, analysis element method to analyze a deformable array transducer; or control as a varying voltage [2]. and Yu and Lan [13] presented system modeling for the de- Piezoelectric accelerometers have the advantages of low sign of a microaccelerometer. However, it should be pointed cost, simple structure, easy integration with electronic cir- out that all of these studies simply assume that the piezo- cuitry, wide frequency response and high sensitivity. Thus, electric PZT thin films are very thin and can be neglected in the mechanical analysis. Considering that the thickness of ∗ Corresponding author. Tel.: +1-412-6244885; fax: +1-412-6244846. PZT films deposited on-chip by sol–gel spin-on deposition, E-mail address: [email protected] (Q.-M. Wang). or screen printing are typically from 0.5 to 5 ␮m, even up to 0924-4247/$ – see front matter © 2004 Elsevier B.V. All rights reserved. doi:10.1016/j.sna.2004.02.041 2 Q.-M. Wang et al. / Sensors and Actuators A 113 (2004) 1–11 20 ␮m [14,15], the effect of thickness and the elastic prop- PZT thin film elements, thus, greatly enhance the sensitivity erties of piezoelectric films should be taken into considera- of the device. Each piezoelectric transducer is composed tion in structural analysis and device performance modeling. of an upper electrode, a piezoelectric thin film and a lower Inclusion of the effects of film thickness in analysis would electrode. The two PZT elements on each beam are poled provide a more accurate estimation of device performance in opposite directions along the thickness. To collect the and, therefore, would aid in device design. generative electric charge from the thin film piezoelectric The aim of this paper is to study both the static and dy- elements when the accelerometer is subjected to an applied namic behavior of the microaccelerometer accounting for acceleration, the two PZT thin film transducer elements on the effect of PZT film thickness. Both an analytical and a each beam can be connected electrically either in parallel or computational model are developed and the results are com- in series. In the case of series connection, the two PZT thin pared. Using the analytical model, the effects of device ge- film elements are connected through the lower electrodes, ometry and the elastic properties of PZT thin film on the while output electrical terminals (connections) are made sensitivity of the accelerometer are evaluated. The results of through the two top electrodes, as shown in Fig. 2(a). Since, this analysis can be used as a base for thin film piezoelectric the stresses of the two PZT elements are in the opposite di- microaccelerometer design and performance optimization. rections due to bending of the beam, i.e. one is subjected to tensile stress and the other compressive stress; the two series connected elements behave like two series voltage sources. 2. Analytical models of thin film piezoelectric In the case of parallel connection, the electrical terminals accelerometer are made through the top electrode and the bottom electrode. The two piezoelectric thin film elements connected in par- 2.1. Static analysis allel behave like two current sources in parallel. In order to connect the two elements in parallel, the two elements need Generally, the two important parameters in evaluating ac- not to be separated physically by etching processing, but the celerometer sensors are sensitivity and operating frequency top electrodes for each element need be separated during range. Sensitivity can be defined as the generative charge per poling process so that opposite polarization can be produced applied acceleration. Operating frequency range is the flat for the two elements. After poling, the top electrodes can frequency response region below the fundamental resonance be connected by depositing a thin film conductive layer on frequency of the sensor. We consider a microaccelerometer the top of the two devices so that it serves as one electrical configuration with four suspended symmetric beams and terminal. In this paper, for simplicity, we will focus on the a central proof mass. The PZT thin film on each flexural first case with the coordinate system is shown in Fig. 2(a). beam is patterned into two transducer elements, thus eight In practical fabrication of PZT thin film devices on silicon piezoelectric transducers are arranged on four beams sym- chip, sol–gel spin-on coating for PZT films is commonly metrically to form the sensing devices in the structures, as used. A few micrometer up to 10 ␮m thick PZT films and shown in Fig. 1. Yu and Lan [13] have adopted a similar con- their properties have been reported [15–18]. The piezoelec- figuration in their device analysis. When the central mass is tric PZT thin film devices are usually with the multilayer subjected to vertical vibration (acceleration), the suspending structure Pt/Ti/PZT/Pt/Ti/SiO2/Si(1 0 0), in which Pt/Ti elec- flexural beam structure can effectively convert and amplify trodes are very thin, typically from 100 to 150 nm. It is the vertical force (or vibration) of the central mass into the well known that the use of Ti thin film (∼10–40 nm) adhe- planar stress in the transverse direction of the piezoelectric sion layer greatly promotes the bonding strength between the platinum layers with SiO2 and PZT [19]. For simplicity, we ignore the effect of electrode layers in our analysis in this paper, with only PZT/Si two-layer structure for the sus- pended beams being considered for the thin film microac- celerometer modeling. The geometry of the accelerometer structure used for our modeling is given in Table 1. Table 1 Component dimensions in a piezoelectric accelerometer Length of suspension beam, l (␮m) 400 Width of suspension beam, b (␮m) 200 Thickness of suspension beam, h (␮m) 5 Length of seismic mass, lm (␮m) 800 Thickness of seismic mass, hm (␮m) 300 Thickness of PZT film, hPZT (␮m) 0.5–5 Seismic mass, m (mg) 0.26 Fig. 1. A 3D view of the piezoelectric thin film microaccelerometer. Q.-M. Wang et al. / Sensors and Actuators A 113 (2004) 1–11 3 Fig. 2. Piezoelectric thin film elements are connected in (a) series or (b) in parallel. The following assumptions are made in establishing the the beam suspension. Fig. 3 shows the schematic free-body mechanical model of the PZT thin film microaccelerometer: diagram of one of the supporting beams.
Recommended publications
  • Piezoelectric Pressure Sensor Based on Enhanced Thin-Film PZT Diaphragm Containing Nanocrystalline Powders
    Chapter 6 Piezoelectric Pressure Sensor Based on Enhanced Thin-Film PZT Diaphragm Containing Nanocrystalline Powders Vahid Mohammadi, Saeideh Mohammadi and Fereshteh Barghi Additional information is available at the end of the chapter http://dx.doi.org/10.5772/54755 1. Introduction During recent years, the study of micro-electromechanical systems (MEMS) has shown that there are significant opportunities for micro sensors and microactuators based on various physical mechanisms such as piezoresistive, capacitive, piezoelectric, magnetic, and electro‐ static. In addition, specialized processes, novel materials, and customized packaging meth‐ ods are routinely used. MEMS themes include miniaturization, multiplicity, and microelectronic manufacturing and integration. Huge technology opportunities for MEMS are present in automotive applications, medicine, defense, controls, and communications. Other applications include biomedical pressure sensors and projection displays. For several excellent MEMS overviews of both core technologies and emerging applications, the readers are encouraged to consult references [1–4]. MEMS can be classified in two major categories: sensors and actuators. MEMS sensors, or microsensors, usually rely on integrated microfabrication methods to realize mechanical structures that predictably deform or respond to a specific physical or chemical variable. Such responses can be observed through a variety of physical detection methods including electronic and optical effects. Structures and devices are designed to be sensitive to changes in resistance (piezoresistivity), changes in capacitance, and changes in charge (piezoelectrici‐ ty), with an amplitude usually proportional to the magnitude of the stimulus sensed. Exam‐ ples of microsensors include accelerometers, pressure sensors, strain gauges, flow sensors, thermal sensors, chemical sensors, and biosensors. MEMS actuators, or microactuators, are usually based on electrostatic, piezoelectric, magnetic, thermal, and pneumatic forces.
    [Show full text]
  • Piezoelectric Chemical Sensors
    Pure Appl. Chem., Vol. 76, No. 6, pp. 1139–1160, 2004. © 2004 IUPAC INTERNATIONAL UNION OF PURE AND APPLIED CHEMISTRY ANALYTICAL CHEMISTRY DIVISION* PIEZOELECTRIC CHEMICAL SENSORS (IUPAC Technical Report) Prepared for publication by RICHARD P. BUCK1, ERNO˝ LINDNER2,‡, WLODZIMIERZ KUTNER3, AND GYÖRGY INZELT4 1Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA; 2Department of Biomedical Engineering, The University of Memphis, Herff College of Engineering, Memphis, TN 38512, USA; 3Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, PL-01 224 Warszawa, Poland; 4Department of Physical Chemistry, Eötvös Loránd University, Budapest, Pázmány Péter sétány 1/A, H-1117, Hungary *Membership of the Analytical Chemistry Division during the final preparation of this report (2002–2003) was as follows: President: D. Moore (USA); Titular Members: F. Ingman (Sweden); K. J. Powell (New Zealand); R. Lobinski (France); G. G. Gauglitz (Germany); V. P. Kolotov (Russia); K. Matsumoto (Japan); R. M. Smith (UK); Y. Umezawa (Japan); Y. Vlasov (Russia); Associate Members: A. Fajgelj (Slovenia); H. Gamsjäger (Austria); D. B. Hibbert (Australia); W. Kutner (Poland); K. Wang (China); National Representatives: E. A. G. Zagatto (Brazil); M.-L. Riekkola (Finland); H. Kim (Korea); A. Sanz-Medel (Spain); T. Ast (Yugoslavia). ‡Corresponding author Republication or reproduction of this report or its storage and/or dissemination by electronic means is permitted without the need for formal IUPAC permission on condition that an acknowledgment, with full reference to the source, along with use of the copyright symbol ©, the name IUPAC, and the year of publication, are prominently visible. Publication of a translation into another language is subject to the additional condition of prior approval from the relevant IUPAC National Adhering Organization.
    [Show full text]
  • On the Design of a MEMS Piezoelectric Accelerometer
    www.nature.com/scientificreports OPEN On the design of a MEMS piezoelectric accelerometer coupled to the middle ear as an Received: 8 January 2018 Accepted: 19 February 2018 implantable sensor for hearing Published: xx xx xxxx devices A. L. Gesing1, F. D. P. Alves2, S. Paul1 & J. A. Cordioli1 The presence of external elements is a major limitation of current hearing aids and cochlear implants, as they lead to discomfort and inconvenience. Totally implantable hearing devices have been proposed as a solution to mitigate these constraints, which has led to challenges in designing implantable sensors. This work presents a feasibility analysis of a MEMS piezoelectric accelerometer coupled to the ossicular chain as an alternative sensor. The main requirements of the sensor include small size, low internal noise, low power consumption, and large bandwidth. Diferent designs of MEMS piezoelectric accelerometers were modeled using Finite Element (FE) method, as well as optimized for high net charge sensitivity. The best design, a 2 × 2 mm2 annular confguration with a 500 nm thick Aluminum Nitride (AlN) layer was selected for fabrication. The prototype was characterized, and its charge sensitivity and spectral acceleration noise were found to be with good agreement to the FE model predictions. Weak coupling between a middle ear FE model and the prototype was considered, resulting in equivalent input noise (EIN) lower than 60 dB sound pressure level between 600 Hz and 10 kHz. These results are an encouraging proof of concept for the development of MEMS piezoelectric accelerometers as implantable sensors for hearing devices. Over 10% of the world’s population is afected by hearing losses1, a disability which incurs in lower quality life and even reduced income.
    [Show full text]
  • Charge Amplifier Type 5050B
    Electronics and Software Charge Amplifier Type 5050B... In-line TEDS Charge Amplifier Module A signal processing device that converts the charge signal from a high impedance piezoelectric sensor into a voltage signal at a low impedance level. Used with high impedance acceleration sensors for performing dynamic measurements in a wide variety of applications. • Two-wire, single-ended device • Rugged, stainless steel case • Wide frequency response • Five gain versions • ä conforming • IEPE compatibility • TEDS option available 2.79 Description 0.17 0.47 The 5050B... in-line TEDS charge amplifier series contains ø0.625 miniature charge amplifiers that convert the charge signal from a stand-alone high impedance piezoelectric sensor into a high level voltage signal at a low impedance output. This two-wire, single-ended device is in five fixed gain settings 0.1, 0.5, 1, 10, and 25 mV/pC with a frequency response of KIAG 10-32 neg. Connector BNC neg. Connector 0.5 Hz ... 50 kHz. Type 5050B... T-version includes a TEDS (sensor input) (output) (Transducer Electronic Data Sheet) chip for storage and retrieval of information. The charge converters can be powered by several Kistler Piezotron power supply couplers or any industry standard IEPE (Integrated Electronic Piezo-Electric) compatible power source. Installation Application Typically, the sensor is placed in a high temperature environment The combination of Type 5050B... in-line TEDS charge amplifier and the charge converter is located some distance away at a and power supply/coupler is a less expensive alternative to location within its operating temperature range. laboratory style charge amplifiers. The charge amplifier is inserted in the signal line between a high impedance sensor and follow- High temperature cable such as the Type 1635Csp is used to on signal conditioning.
    [Show full text]
  • Industrial Vibration Accelerometer Performance Considerations: Shear Versus Compression Designs
    Industrial Vibration Accelerometer Performance Considerations: Shear versus Compression Designs By: David A. Corelli Category IV Vibration Analyst Director of Application Engineering IMI Sensors Molly Bakewell Global PR, Advertising & Image Manager PCB Piezotronics, Inc. www.pcb.com The implementation of industrial vibration monitoring sensors and associated signal conditioning as an integral part of industrial predictive maintenance programs has proven for many maintenance and plant engineers to be an effective strategy for reducing downtime and improving overall machinery health. Vibration monitoring technology is widely used because of its ability to detect and diagnose a wide variety of machinery faults, such as bearing faults, gear problems, misalignment, looseness, mass imbalance, and others, on a wide variety of rotating machinery, and its relative ease of integration with portable data collectors, online vibration monitoring systems, PLC’s, qne SCADA and Plant Information (PI) systems. For the proper implementation of sensors into a vibration monitoring program, one must first understand the differences in the two most common designs of industrial piezoelectric sensors, as well as various considerations in selection and mounting. A piezoelectric accelerometer produces a measurable electrical signal when an inertial mass stresses, or applies a force to, its integral crystal sensing element. The two main types of piezoelectric sensor designs most typically used for industrial vibration monitoring applications are shear and compression, which define the actual mode, or crystal axis, in which an inertial mass stresses the piezoelectric crystal. While both types operate in a similar fashion, one of these designs provides much more reliable and repeatable performance when acted upon by certain external influences within the demanding industrial application environment.
    [Show full text]
  • Velocity Measurements Using a Piezoelectric Plate As a Sensor
    University of Texas at El Paso ScholarWorks@UTEP Open Access Theses & Dissertations 2020-01-01 Velocity Measurements Using A Piezoelectric Plate As A Sensor Paul Perez University of Texas at El Paso Follow this and additional works at: https://scholarworks.utep.edu/open_etd Part of the Mechanical Engineering Commons Recommended Citation Perez, Paul, "Velocity Measurements Using A Piezoelectric Plate As A Sensor" (2020). Open Access Theses & Dissertations. 3020. https://scholarworks.utep.edu/open_etd/3020 This is brought to you for free and open access by ScholarWorks@UTEP. It has been accepted for inclusion in Open Access Theses & Dissertations by an authorized administrator of ScholarWorks@UTEP. For more information, please contact [email protected]. VELOCITY MEASUREMENTS USING A PIEZOELECTRIC PLATE AS A SENSOR PAUL ALFREDO PEREZ ITURRALDE Master’s Program in Mechanical Engineering APPROVED: Norman Love, Ph.D., Chair Yirong Lin, Ph.D. Tzu-Liang (Bill) Tseng, Ph.D. Stephen L. Crites, Jr., Ph.D. Dean of the Graduate School Copyright © by Paul Alfredo Perez Iturralde 2020 Dedication I dedicated this work to my parents and siblings because they are the main foundation of my values, they laid my foundations of responsibility and desires for professional improvement. EXPERIMENTAL SET UP FOR THE TESTING OF A PIEZOELECTRIC MASS FLOW RATE SENSOR by PAUL ALFREDO PEREZ ITURRALDE THESIS Presented to the Faculty of the Graduate School of The University of Texas at El Paso in Partial Fulfillment of the Requirements for the Degree of MASTER OF SCIENCE Department of Mechanical Engineering THE UNIVERSITY OF TEXAS AT EL PASO May 2020 Acknowledgements This thesis has been funded by National Energy Technology Laboratory (NETL).
    [Show full text]
  • Design of a Piezoelectric Accelerometer with High Sensitivity and Low Transverse Effect
    sensors Article Design of a Piezoelectric Accelerometer with High Sensitivity and Low Transverse Effect Bian Tian, Hanyue Liu *, Ning Yang, Yulong Zhao and Zhuangde Jiang State Key Laboratory for Mechanical Manufacturing Systems Egineering, Xi’an Jiaotong University, Xi’an 710049, China; [email protected] (B.T.); [email protected] (N.Y.); [email protected] (Y.Z.); [email protected] (Z.J.) * Correspondence: [email protected]; Tel.: +86-29-8339-5171 Academic Editor: Jörg F. Wagner Received: 19 July 2016; Accepted: 21 September 2016; Published: 26 September 2016 Abstract: In order to meet the requirements of cable fault detection, a new structure of piezoelectric accelerometer was designed and analyzed in detail. The structure was composed of a seismic mass, two sensitive beams, and two added beams. Then, simulations including the maximum stress, natural frequency, and output voltage were carried out. Moreover, comparisons with traditional structures of piezoelectric accelerometer were made. To verify which vibration mode is the dominant one on the acceleration and the space between the mass and glass, mode analysis and deflection analysis were carried out. Fabricated on an n-type single crystal silicon wafer, the sensor chips were wire-bonged to printed circuit boards (PCBs) and simply packaged for experiments. Finally, a vibration test was conducted. The results show that the proposed piezoelectric accelerometer has high sensitivity, low resonance frequency, and low transverse effect. Keywords: piezoelectric accelerometer; high sensitivity; low resonance frequency; low transverse effect 1. Introduction With the development of urbanization, cables have gradually been replacing overhead lines due to their merits of being a reliable power supply, having a simple operation, and being a less occupying area.
    [Show full text]
  • Modelling and Trials of Pyroelectric Sensors for Improving Its Application for Biodevices
    MODELLING AND TRIALS OF PYROELECTRIC SENSORS FOR IMPROVING ITS APPLICATION FOR BIODEVICES Andrés Díaz Lantada, Pilar Lafont Morgado, Héctor Hugo del Olmo, Héctor Lorenzo-Yustos Javier Echavarri Otero, Juan Manuel Munoz-Guijosa, Julio Muñoz-García and José Luis Muñoz Sanz Grupo de Investigación en Ingeniería de Máquinas – E.T.S.I. Industriales – Universidad Politécnica de Madrid C/ José Gutiérrez Abascal, nº 2. 28006 – Madrid, Spain Keywords: Pyroelectricity, Ferroelectric Polymers, Sensors Behaviour, Medical Devices. Abstract: Active or “Intelligent” Materials are capable of responding in a controlled way to different external physical or chemical stimuli by changing some of their properties. These materials can be used to design and develop sensors, actuators and multifunctional systems with a large number of applications for developing medical devices. Pyroelectric materials, with thermoelectrical properties coupling, can be used as temperature sensors with applications in the development of several biodevices, including the combination with other thermally active materials, whose actuation can be improved by means of precise temperature registration. This paper makes an introduction to pyroelectricity and its main applications in the development of biodevices, focusing also in the pyroelectric properties of polyvinylidene fluoride or PVDF and presenting some results related with sensors’ behaviour modelling and characterization. 1 INTRODUCTION TO During the last decades important progress has been made in creating artificial pyroelectric PYROELECTRICITY materials, usually in the form of a thin film, out of gallium nitride (GaN), caesium nitrate (CsNO3), Pyroelectricity is the ability of certain materials to polyvinylidene fluorides (PVDF and copolymers), generate an electrical potential when they are heated derivatives of phenylpyrazine cobalt phthalocyanine or cooled.
    [Show full text]
  • Piezoelectric Accelerometer with Improved Temperature Stability By
    Title Page Piezoelectric Accelerometer with Improved Temperature Stability by Wenhao Huang B.E., University of Pittsburgh, 2019 Submitted to the Graduate Faculty of the Swanson School of Engineering in partial fulfillment of the requirements for the degree of Master of Science in Mechanical Engineering University of Pittsburgh 2021 Committee Page UNIVERSITY OF PITTSBURGH SWANSON SCHOOL OF ENGINEERING This thesis was presented by Wenhao Huang It was defended on April 8, 2021 and approved by Qing-Ming Wang, Ph.D., Professor Department of Mechanical Engineering and Materials Science Patrick Smolinski, Ph.D., Assosiate Professor Department of Mechanical Engineering and Materials Science Heng Ban, Ph.D., Professor Department of Mechanical Engineering and Materials Science Thesis Advisor: Qing-Ming Wang, Ph.D., Professor Department of Mechanical Engineering and Materials Science ii Copyright © by Wenhao Huang 2021 iii Abstract Piezoelectric Accelerometer with Improved Temperature Stability Wenhao Huang, M.S. University of Pittsburgh, 2021 Piezoceramic materials like PZT allow the manufacturing of piezoelectric sensors with advantages including high sensitivity, low price, and easy to shape. However, it is also featured with the pyroelectric effect, which brings extra charge generation with temperature variations. Those charges caused by the thermal effect contribute to errors in the sensor measurement result. Theoretically, the appropriate configuration of the sensor would neutralize the thermal effect. In this thesis, a triple layer piezoelectric sensor with a parallel connection would be used to check its thermal stability at elevated temperatures. The thesis begins with reviewing the fundamental concepts of piezoelectricity. The following section contains the analysis of the relationship between the different external inputs and the output of a triple layer sensor.
    [Show full text]
  • Piezotron Coupler Type 5118B2 Piezoelectric Sensor Power Supply/Coupler
    Pressure Piezotron coupler Type 5118B2 Piezoelectric sensor power supply/coupler A flexible, easy-to-use signal conditioner that provides excitation power, signal tailoring, and acts as an interface between voltage mode piezoelectric sensors and measuring instru ments. Single channel unit powered by internal AA bat- teries or an AC/DC adaptor. • Selectable gain and low-pass, plug-in filters • High-pass filtering, panel selectable • Monitor the condition of the sensors and cables • Exclusive “Rapid Zero” feature • AC, DC or battery powered • Conforming to ä Description Dimensions The signal conditioner provides the constant current 12,8 excitation required by low impedance, voltage mode sensors with 165 built-in electronics (i.e. Piezotron, PiezoBeam, K-Shear, and Ceramic Shear) or for high impedance sensors with an external impedance converter. Sensor power is supplied by the same 44,7 2-wire cable that provides the low impedance output signal. Type 5118B2 decouples the DC bias voltage from the output 25,4 signal and provides a 2 mA constant current source, which SIDE VIEW can also be factory adjusted from 2 ... 18 mA. Bias indicators display the condition of the sensor and cable. Amplifier gains TOP VIEW of 1x, 10x and 100x are selectable from a front panel switch. High-pass filter cutoff frequencies (–3 dB) 0.006 and 0.03 Hz are also selectable by a switch on the front panel. Plug-in, low-pass filters are available to limit the frequency response of the amplifier. These low-pass filters can be used to atten- 90,4 uate unwanted frequency and/or to improve signal-to-noise ratio.
    [Show full text]
  • "Signal Conditioning Piezoelectric Sensors"
    Application Report SLOA033A - September 2000 Signal Conditioning Piezoelectric Sensors James Karki Mixed Signal Products ABSTRACT Piezoelectric elements are used to construct transducers for a vast number of different applications. Piezoelectric materials generate an electrical charge in response to mechanical movement, or vice versa, produce mechanical movement in response to electrical input. This report discusses the basic concepts of piezoelectric transducers used as sensors and two circuits commonly used for signal conditioning their output. Contents 1 Introduction . 1 2 Theory and Modeling . 2 3 Signal Conditioning . 2 3.1 Voltage Mode Amplifier. 3 3.2 Charge Mode Amplifier. 4 3.3 Signal Conditioning Made Easier. 4 Appendix A . 5 List of Figures 1 Sensor Models . 2 2 Voltage Mode Amplifier Circuit. 3 3 Charge Mode Amplifier Circuit. 4 1 Introduction The word piezo comes from the Greek word piezein, meaning to press or squeeze. Piezoelectricity refers to the generation of electricity or of electric polarity in dielectric crystals when subjected to mechanical stress and conversely, the generation of stress in such crystals in response to an applied voltage. In 1880, the Curie brothers found that quartz changed its dimensions when subjected to an electrical field and generated electrical charge when pressure was applied. Since that time, researchers have found piezoelectric properties in hundreds of ceramic and plastic materials. Many piezoelectric materials also show electrical effects due to temperature changes and radiation. This report is limited to piezoelectricity. More detailed information on particular sensors can be found by contacting the manufacturer. 2 Theory and Modeling The basic theory behind piezoelectricity is based on the electrical dipole.
    [Show full text]
  • Piezotron Coupler Type 5114
    Electronics & Software Piezotron Coupler Type 5114... Versatile voltage mode piezoelectric sensor power supply/coupler A self contained power source that provides excitation power and acts as an interface between voltage mode piezoelectric sensors and measuring instruments. Single channel unit pow- ered by internal 9 volt battery or an AC/DC adaptor. • Provides constant current excitation • Monitors condition of sensors and cables • 3.5 digit LCD display • AC, DC or battery powered • Conforming to CE Description Type 5114 is a single channel signal conditioner that provides- constant current excitation required by low impedance voltage mode sensors with built-in electronics (i.e. Piezotron, Piezo- Beam, K-Shear, and Ceramic Shear) or for high impedance sensors with an external impedance converter. Sensor power is supplied by the same two-wire cable that provides the low impedance, output signal. Type 5114 decouples the DC bias voltage from the output signal. A 3.5 digit LCD with 0.5 inch high digits indicates sensor DC bias voltage. Three light-emitting diode on the display panel indicate the basic status of the sensor circuit. Bias voltages in the range of 4 to 16 volts are normal and result in a “Normal” (green) indication; bias voltages below 4 volts (see model ex- ception note 2) produce a “Short” (red) indication; and, a volt- age above 16 volts will result in an “Open” (yellow) indication. The unit operates from a single 9 volt battery or DC power from an external AC/DC power adapter. “LOBAT” is indicated on the LCD readout when battery replacement is required. One 9 volt battery is installed in a compartment in the bottom of the case and operates 36 hours.
    [Show full text]