Intel® Quick Sync Video and Ffmpeg Installation and Validation Guide
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Intel® Quick Sync Video Technology Guide
WP80 Superguide 3: THE CLOUD VIDEO SUPERGUIDE JANUARY/FEBRUARY 2015 SPONSORED CONTENT Intel® Quick Sync Video Technology and Intel® Xeon® Processor Based Servers— Flexible Transcode Performance and Quality Video transcoding involves converting provides enterprise-quality HEVC and and boost image quality. Some key one compressed video format to audio codecs, Intel® VTune™ Amplifier improvements include the following: another. In the past this process has XE performance analysis tools and Video • Additional JPEG/MJPEG decode in been a compute-intensive task which Quality Caliper stream quality analyzer. the multi-format codec engine. This demanded a large amount of precious Additionally, product family members, support is on top of existing energy- CPU resources. Intel® Quick Synch Video Intel® Video Pro Analyzer and Intel® efficient, high-performance AVC (QSV) can enable hardware-accelerated Stress Bitstreams and Encoder bundles encode/decode that sustains multiple transcoding to deliver better performance enable production–scale validation and 4K and Ultra HD video streams. than transcoding on the CPU without debug of encode, transcode, and decode • A dedicated new video quality engine sacrificing quality. and playback applications. to provide extensive video processing First introduced in 2011, Intel Quick Intel Media Server Studio SDK at low power consumption Sync technology is available in the Intel® implements many codec and tools • Programmable and media-optimized Xeon® Processor E3-1200 v3 with Intel components initially in software, and EU (execution units)/samplers for HD Graphics P4600/4700 and Iris™ Pro later as hybrid (software and hardware) high quality P5200. (From here on, we’ll simply refer to or entirely in hardware. -
GPU Developments 2018
GPU Developments 2018 2018 GPU Developments 2018 © Copyright Jon Peddie Research 2019. All rights reserved. Reproduction in whole or in part is prohibited without written permission from Jon Peddie Research. This report is the property of Jon Peddie Research (JPR) and made available to a restricted number of clients only upon these terms and conditions. Agreement not to copy or disclose. This report and all future reports or other materials provided by JPR pursuant to this subscription (collectively, “Reports”) are protected by: (i) federal copyright, pursuant to the Copyright Act of 1976; and (ii) the nondisclosure provisions set forth immediately following. License, exclusive use, and agreement not to disclose. Reports are the trade secret property exclusively of JPR and are made available to a restricted number of clients, for their exclusive use and only upon the following terms and conditions. JPR grants site-wide license to read and utilize the information in the Reports, exclusively to the initial subscriber to the Reports, its subsidiaries, divisions, and employees (collectively, “Subscriber”). The Reports shall, at all times, be treated by Subscriber as proprietary and confidential documents, for internal use only. Subscriber agrees that it will not reproduce for or share any of the material in the Reports (“Material”) with any entity or individual other than Subscriber (“Shared Third Party”) (collectively, “Share” or “Sharing”), without the advance written permission of JPR. Subscriber shall be liable for any breach of this agreement and shall be subject to cancellation of its subscription to Reports. Without limiting this liability, Subscriber shall be liable for any damages suffered by JPR as a result of any Sharing of any Material, without advance written permission of JPR. -
Keepixo’S Genova Live:Speed Is the Latest Addition to Genova Virtualizable Software Family of Products
High Density Video Transcoding Keepixo’s Genova Live:Speed is the latest addition to Genova Virtualizable Software family of products. It runs on the Kontron SYMKLOUD platform and leverages Intel’s Quick Sync Video (QSV) technology to dramatically increase transcoding density; minimize power consumption while meeting professional service grade levels. Media Processing Acceleration Genova Live:Speed The explosive growth of Internet video traffic has put Keepixo worked with Kontron to leverage the Kontron pressure on video transcoding infrastructures to SYMKLOUD Converged Infrastructure platform and optimize bandwidth, power consumption and cost of developed a comprehensive package that optimizes the operations. High density transcoding solutions such as performance of QSV and allows smooth deployment of Intel’s Quick Sync Video technology have emerged to highly dense transcoding infrastructures comprising of address these challenges. They introduce various levels hundreds of services. of HW acceleration to off-load computationally intensive tasks. Initially targeted at consumer Keepixo selected the Kontron SymKloud MS2910 applications, high density transcoding has become a platform to implement its high density transcoding viable option for professional transcoding solution. The MS2910 platform comes in a 2U (21” infrastructures when included in suitable packages that depth) chassis, dual hot-swappable 10GbE switches, address the requirements of professional applications. and can accommodate up to 9 modular compute servers, each hosting 2 independent CPUs for a total of Intel Quick Sync Video (QSV) is available on a range of up to 18 CPUs per chassis. The SymKloud compute Intel i7 and Xeon E3 processors fitted with on-chip nodes can be of different mix-and-match processor graphics. -
Rethinking Visual Cloud Workload Distribution
WHITE PAPER Media and Communications Content Creation and Distribution RethinkingVisualCloud WorkloadDistribution Creating a New Model With visual computing workloads growing at an accelerating pace, cloud service providers (CSPs), communications service providers (CoSPs), and enterprises are rethinking the physical and virtual distribution of compute resources to more effectively balance cost and deployment efficiency while achieving exceptional performance. Visual cloud deployments accommodate a diverse range of streaming workloads, encompassing media processing and delivery, cloud graphics, cloud gaming, media analytics, and immersive media. Contending with the onslaught of new visual workloads will require more nimble, scalable, virtualized infrastructures; the capability of shifting workloads to the network edge when appropriate; and a collection of tools, software, and hardware components to support individual use cases fluidly. Advanced network technologies and cloud architectures are essential for agile distribution of visual cloud workloads. A 2017 report, Cisco Visual Networking Index: Forecast and Methodology, 2016–2021, projected strong growth in all Internet and managed IP video- related sectors. Compound annual growth rate (CAGR) figures during this time span, calculated in petabytes per month, included these predictions: • Content delivery network (CDN) traffic: 44 percent increase globally • Consumer-managed IP video traffic: 19,619 petabytes per month (14 percent increase) by 2021 • Consumer Internet video: 27 percent increase for fixed, 55 percent increase for mobile The impact of this media growth on cloud-based data centers will produce a burden on those CSPs, CoSPs, and enterprises that are not equipped to deal with TableofContents large-scale media workloads dynamically. Solutions to this challenge include: Creating a New Model . 1 • Increasingflexibilityandoptimizingprocessing: Virtualization and software- defined infrastructure (SDI) make it easier to balance workloads on available OpenSourceSoftware resources. -
Hardware Based Compression in Ceph OSD with BTRFS
Hardware Based Compression in Ceph OSD with BTRFS Weigang Li ([email protected]) Tushar Gohad ([email protected]) Data Center Group Intel Corporation 2016 Storage Developer Conference. © Intel Corp. All Rights Reserved. Credits This work wouldn’t have been possible without contributions from – Reddy Chagam ([email protected]) Brian Will ([email protected]) Praveen Mosur ([email protected]) Edward Pullin ([email protected]) 2 2016 Storage Developer Conference. © Intel Corp. All Rights Reserved. Agenda Ceph A Quick Primer Storage Efficiency and Security Features Offload Mechanisms – Software and Hardware Compression in Ceph OSD with BTRFS Compression in BTRFS and Ceph Hardware Acceleration with QAT PoC implementation Performance Results Key Takeaways 3 2016 Storage Developer Conference. © Intel Corp. All Rights Reserved. Ceph Open-source, object-based scale-out storage system Software-defined, hardware-agnostic – runs on commodity hardware Object, Block and File support in a unified storage cluster Highly durable, available – replication, erasure coding Replicates and re-balances dynamically 4 Image source: http://ceph.com/ceph-storage 2016 Storage Developer Conference. © Intel Corp. All Rights Reserved. Ceph Scalability – CRUSH data placement, no single POF Enterprise features – snapshots, cloning, mirroring Most popular block storage for Openstack use cases 10 years of hardening, vibrant community 5 Source: http://www.openstack.org/assets/survey/April-2016-User-Survey-Report.pdf 2016 Storage Developer Conference. © Intel Corp. All Rights Reserved. Ceph: Architecture OSD OSD OSD OSD OSD btrfs xfs ext4 POSIX Backend Backend Backend Backend Backend Bluestore KV DISK DISK DISK DISK DISK Commodity Servers M M M 6 2016 Storage Developer Conference. -
GNUPG Open Source Encryption on HP Nonstop
GNUPG Open Source Encryption on HP NonStop Damian Ward NonStop Solutions Architect / BITUG Vice Chairman Confidential Introduction What am I going to talk about today • About Me • About VocaLink • History of encryption • PGP to GNUPG • PGP encryption walkthrough • Installing GNUPG • Use Case • Questions..? Please feel free to ask as we go through the presentation. Confidential 2 Introduction About your presenter • Damian Ward • 20+ years HP NonStop and Payments experience • Career spanning: − Operations, Application Programming, System Management, Programme Management, Technical Specialist, Solutions Architect, Enterprise Architect, Infrastructure Architect • Specialities: − HP NonStop systems and architecture, Enterprise Architecture, Encryption, Availability Management, ATM Systems, Payments Processing, Capacity Planning, System modelling, Fraud, Mobile and Internet technologies, Programming, Emerging Technologies and Robotics • BITUG Vice Chairman 2011 • BITUG Chairman 2012 Confidential 3 Introduction VocaLink: cards processing landscape Direct connection to in house processing system Indirect ATM acquirer and card issuer connection (via VocaLinkCSB) FIS Connex Advantage Connections to Mobile Switch with resillient Operators Indirect ATM connection (via third telecommunication party processor) connections to each customer Connections to Direct connection overseas to Post Office via TNS CSB schemes and systems ATM and POS international banks acquiring and issuing connections via gateway connections to international schemes Confidential -
FPGA-Based ZLIB/GZIP Compression As an Nvme Namespace
FPGA-Based ZLIB/GZIP Compression as an NVMe Namespace Saeed Fouladi Fard Eideticom 2018 Storage Developer Conference. © Eidetic Communications Inc. All Rights Reserved. 1 Why NVMe ❒ NVMe: A standard specification for accessing non-volatile media over PCIe ❒ High-speed and CPU efficient ❒ In-box drivers available for major OSes ❒ Allows peer-to-peer data transfers ❒ Reduces system memory access ❒ Frees CPU time 2018 Storage Developer Conference. © Eidetic Communications Inc. All Rights Reserved. 2 Why NVMe, Cont’d Host ❒ NVMe can be used as a high speed Memory CPU platform for using PCIe and sharing NVMe SSD NVMe SSD NVMe SSD NVMe accelerators with Accelerator Accelerator Accelerator NVMe NVMe NVMe low overhead ❒ Easy to use Accels 2018 Storage Developer Conference. © Eidetic Communications Inc. All Rights Reserved. 3 Hardware Platform TM ❒ Called NoLoad = NVMe Offload TM ❒ NoLoad can present FPGA accelerators as NVMe namespaces to the host computer or peers ❒ Accelerator integration, verification, and discovery is mostly automated ❒ Host software can be added to use the accelerator Streamlined Accelerator Integration 2018 Storage Developer Conference. © Eidetic Communications Inc. All Rights Reserved. 4 NoLoadTM Software Management Applications ❒ Userspace: both kernel nvme-cli & userspace frameworks nvme-of supported etc libnoload SPDK ❒ OS: use inbox NVMe driver (no changes) TM ❒ Hardware: NoLoad Hardware Eval Kits 2018 Storage Developer Conference. © Eidetic Communications Inc. All Rights Reserved. 5 Accelerators as NVMe devices NVMe NSs: 3 Optane SSDs, 3 Compression Accels, 1 RAM-Drive 2018 Storage Developer Conference. © Eidetic Communications Inc. All Rights Reserved. 6 Peer-to-Peer Access ❒ P2P Transfers bypass DRAM DRAM CPU memory and other DDR DDR PCIe subsystems CPU CPU ❒ P2P uses PCIe EP’s memory (e.g., CMB,BAR) PCIe PCIe PCIe PCIe NoLoad NVMe NVMe NVMe ❒ A P2P capable Root CMB Complex or PCIe switch is needed SSD A SSD B SSD A NoLoad with Compression Legacy Datapath Peer-2-Peer Datapath 2018 Storage Developer Conference. -
Scripting the Openssh, SFTP, and SCP Utilities on I Scott Klement
Scripting the OpenSSH, SFTP, and SCP Utilities on i Presented by Scott Klement http://www.scottklement.com © 2010-2015, Scott Klement Why do programmers get Halloween and Christmas mixed-up? 31 OCT = 25 DEC Objectives Of This Session • Setting up OpenSSH on i • The OpenSSH tools: SSH, SFTP and SCP • How do you use them? • How do you automate them so they can be run from native programs (CL programs) 2 What is SSH SSH is short for "Secure Shell." Created by: • Tatu Ylönen (SSH Communications Corp) • Björn Grönvall (OSSH – short lived) • OpenBSD team (led by Theo de Raadt) The term "SSH" can refer to a secured network protocol. It also can refer to the tools that run over that protocol. • Secure replacement for "telnet" • Secure replacement for "rcp" (copying files over a network) • Secure replacement for "ftp" • Secure replacement for "rexec" (RUNRMTCMD) 3 What is OpenSSH OpenSSH is an open source (free) implementation of SSH. • Developed by the OpenBSD team • but it's available for all major OSes • Included with many operating systems • BSD, Linux, AIX, HP-UX, MacOS X, Novell NetWare, Solaris, Irix… and yes, IBM i. • Integrated into appliances (routers, switches, etc) • HP, Nokia, Cisco, Digi, Dell, Juniper Networks "Puffy" – OpenBSD's Mascot The #1 SSH implementation in the world. • More than 85% of all SSH installations. • Measured by ScanSSH software. • You can be sure your business partners who use SSH will support OpenSSH 4 Included with IBM i These must be installed (all are free and shipped with IBM i **) • 57xx-SS1, option 33 = PASE • 5733-SC1, *BASE = Portable Utilities • 5733-SC1, option 1 = OpenSSH, OpenSSL, zlib • 57xx-SS1, option 30 = QShell (useful, not required) ** in v5r3, had 5733-SC1 had to be ordered separately (no charge.) In v5r4 or later, it's shipped automatically. -
Zlib Home Site
zlib Home Site http://zlib.net/ A Massively Spiffy Yet Delicately Unobtrusive Compression Library (Also Free, Not to Mention Unencumbered by Patents) (Not Related to the Linux zlibc Compressing File-I/O Library) Welcome to the zlib home page, web pages originally created by Greg Roelofs and maintained by Mark Adler . If this page seems suspiciously similar to the PNG Home Page , rest assured that the similarity is completely coincidental. No, really. zlib was written by Jean-loup Gailly (compression) and Mark Adler (decompression). Current release: zlib 1.2.6 January 29, 2012 Version 1.2.6 has many changes over 1.2.5, including these improvements: gzread() can now read a file that is being written concurrently gzgetc() is now a macro for increased speed Added a 'T' option to gzopen() for transparent writing (no compression) Added deflatePending() to return the amount of pending output Allow deflateSetDictionary() and inflateSetDictionary() at any time in raw mode deflatePrime() can now insert bits in the middle of the stream ./configure now creates a configure.log file with all of the results Added a ./configure --solo option to compile zlib with no dependency on any libraries Fixed a problem with large file support macros Fixed a bug in contrib/puff Many portability improvements You can also look at the complete Change Log . Version 1.2.5 fixes bugs in gzseek() and gzeof() that were present in version 1.2.4 (March 2010). All users are encouraged to upgrade immediately. Version 1.2.4 has many changes over 1.2.3, including these improvements: -
System Design for Telecommunication Gateways
P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come SYSTEM DESIGN FOR TELECOMMUNICATION GATEWAYS Alexander Bachmutsky Nokia Siemens Networks, USA A John Wiley and Sons, Ltd., Publication P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come SYSTEM DESIGN FOR TELECOMMUNICATION GATEWAYS P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come SYSTEM DESIGN FOR TELECOMMUNICATION GATEWAYS Alexander Bachmutsky Nokia Siemens Networks, USA A John Wiley and Sons, Ltd., Publication P1: OTE/OTE/SPH P2: OTE FM BLBK307-Bachmutsky August 30, 2010 15:13 Printer Name: Yet to Come This edition first published 2011 C 2011 John Wiley & Sons, Ltd Registered office John Wiley & Sons Ltd, The Atrium, Southern Gate, Chichester, West Sussex, PO19 8SQ, United Kingdom For details of our global editorial offices, for customer services and for information about how to apply for permission to reuse the copyright material in this book please see our website at www.wiley.com. The right of the author to be identified as the author of this work has been asserted in accordance with the Copyright, Designs and Patents Act 1988. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, except as permitted by the UK Copyright, Designs and Patents Act 1988, without the prior permission of the publisher. -
Z/OS Openssh User's Guide
z/OS Version 2 Release 4 z/OS OpenSSH User's Guide IBM SC27-6806-40 Note Before using this information and the product it supports, read the information in “Notices” on page 503. This edition applies to Version 2 Release 4 of z/OS (5650-ZOS) and to all subsequent releases and modifications until otherwise indicated in new editions. Last updated: 2020-11-16 © Copyright International Business Machines Corporation 2015, 2019. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Figures................................................................................................................. ix Tables.................................................................................................................. xi About this document...........................................................................................xiii Who should use this document?............................................................................................................... xiii z/OS information........................................................................................................................................xiii Discussion list...................................................................................................................................... xiii How to send your comments to IBM......................................................................xv If you have a technical problem.................................................................................................................xv -
H P Intel® Quick Sync Video Tec Nology on Intel® Iris™ Graphics
WHITE PAPER Intel Quick Sync Video Intel® Quick Sync Video Tech n ology on Intel® Iris™ Graphics and Intel® HD Grap h ics family—Flexible Transcode Performance an d Quality The 4th generation Intel® Core™ Processor introduces Intel® Iris™ Pro Graphics, Intel® Iris™ Graphics and Intel® HD Graphics (4200+ Series), featuring the newest iteration of Intel® Quick Sync Video technology. In addition, Intel Quick Sync technology is also available in the Intel Xeon® Processor E3-1200 v3 product family with Intel HD Graphics P4600/P4700. For the purposes of this whitepaper, we will refer simply to Intel Quick Sync technology. This advanced graphics solution sets a milestone in performance by delivering a blazingly fast transcode experience, and balances image quality and performance through a series of optimized user targets for easy adoption. This paper explains the changes in Intel Quick Sync Video transcode target usages, describes the new high-performance hardware acceleration engine, and sets performance and quality expectations for each target usage. Introduction In the past, transcoding has been a Video transcoding involves converting one compute-intensive task that demanded a compressed video format to another. The large amount of precious CPU resources. process can apply changes to the format, With multiple cores and more powerful such as moving from MPEG2 to H.264, or processors driving today’s systems, transcoding can change the properties of transcoding happens faster, and is a given format, like bit rate or resolution. commonly used to support the format Conversions cannot generally happen in a requirements of a whole range of video single step; rather, a series of transitions consumption devices.