Chapter 4, Solution 1C.

In transfer analysis, some bodies are observed to behave like a "lump" whose entire body temperature remains essentially uniform at all times during a process. The temperature of such bodies can be taken to be a function of time only. Heat transfer analysis which utilizes this idealization is known as the lumped system analysis. It is applicable when the Biot number (the ratio of conduction resistance within the body to resistance at the surface of the body) is less than or equal to 0.1.

Chapter 4, Solution 2C.

The lumped system analysis is more likely to be applicable for the body cooled naturally since the Biot number is proportional to the convection heat transfer coefficient, which is proportional to the air velocity. Therefore, the Biot number is more likely to be less than 0.1 for the case of natural convection.

Chapter 4, Solution 3C.

The lumped system analysis is more likely to be applicable for the body allowed to cool in the air since the Biot number is proportional to the convection heat transfer coefficient, which is larger in water than it is in air because of the larger of water. Therefore, the Biot number is more likely to be less than 0.1 for the case of the solid cooled in the air

Chapter 4, Solution 4C.

The temperature drop of the potato during the second minute will be less than 4°C since the temperature of a body approaches the temperature of the surrounding medium asymptotically, and thus it changes rapidly at the beginning, but slowly later on.

Chapter 4, Solution 5C.

The temperature rise of the potato during the second minute will be less than 5°C since the temperature of a body approaches the temperature of the surrounding medium asymptotically, and thus it changes rapidly at the beginning, but slowly later on.

Chapter 4, Solution 6C.

Biot number represents the ratio of conduction resistance within the body to convection resistance at the surface of the body. The Biot number is more likely to be larger for poorly conducting solids since such bodies have larger resistances against heat conduction.

Chapter 4, Solution 7C.

The heat transfer is proportional to the surface area. Two half pieces of the roast have a much larger surface area than the single piece and thus a higher rate of heat transfer. As a result, the two half pieces will cook much faster than the single large piece. Chapter 4, Solution 8C.

The cylinder will cool faster than the sphere since heat transfer rate is proportional to the surface area, and the sphere has the smallest area for a given volume.

Chapter 4, Solution 9C.

The lumped system analysis is more likely to be applicable in air than in water since the convection heat transfer coefficient and thus the Biot number is much smaller in air.

Chapter 4, Solution 10C.

The lumped system analysis is more likely to be applicable for a golden apple than for an actual apple since the thermal conductivity is much larger and thus the Biot number is much smaller for gold.

Chapter 4, Solution 11C.

The lumped system analysis is more likely to be applicable to slender bodies than the well-rounded bodies since the characteristic length (ratio of volume to surface area) and thus the Biot number is much smaller for slender bodies.

Chapter 4, Solution 19.

A long copper rod is cooled to a specified temperature. The cooling time is to be determined.

Assumptions 1 The thermal properties of the geometry are constant. 2 The heat transfer coefficient is constant and uniform over the entire surface. 3 Properties The properties of copper are k = 401 W/m⋅ºC, ρ = 8933 kg/m , and cp = 0.385 kJ/kg⋅ºC (Table A-3). Analysis For cylinder, the characteristic length and the Biot number are V π 2 )4/( LD D 02.0 m Lc == === 005.0 m Asurface πDL 4 4 D = 2 cm 2 hLc W/m200( ° 005.0)(C. )m Bi == 0025.0 <= 1.0 Ti = 100 ºC k W/m.401( ° )C Since Bi 0.1< , the lumped system analysis is applicable. Then the cooling time is determined from hA h W/m200 2 °C. b === = 01163.0 s 1- 3 c pV ρρ Lc cp (8933 385)(kg/m J/kg. °C)(0.005 m)

)( −TtT − 2025 1- ∞ e −bt ⎯= ⎯→ = e − 01163.0( )s t ⎯⎯→ t 238 s == 4.0 min i −TT ∞ − 20100

Chapter 4, Solution 21E.

A person shakes a can of drink in a iced water to cool it. The cooling time of the drink is to be determined. Assumptions 1 The can containing the drink is cylindrical in shape with a radius of ro = 1.25 in. 2 The Water thermal properties of the drink are taken to be the same 32°F as those of water. 3 Thermal properties of the drinkare constant at room temperature. 4 The heat transfer DrinkMilk coefficient is constant and uniform over the entire 903°°FC surface. 5 The Biot number in this case is large (much larger than 0.1). However, the lumped system analysis is still applicable since the drink is stirred constantly, so that its temperature remains uniform at all times. Properties The density and specific heat of water at 3 room temperature are ρ = 62.22 lbm/ft , and cp = 0.999 Btu/lbm.°F (Table A-9E). Analysis Application of lumped system analysis in this case gives V π 2 Lr π 12/25.1( 2 12/5(ft) ft) L == o = = 04167.0 ft c A 2 2 s o + 22 ππ rLr o π 12/25.1(2 ft)(5/12 π 12/25.1(2+ft) ft)

hA h 30 2 °F.Btu/h.ft b s === = 583.11 1- = 00322.0h s 1- 3 c pV ρρ Lc cp (62.22 999.0)(lbm/ft Btu/lbm. °F)(0.04167 ft)

)( −TtT − 3240 1- ∞ e −bt ⎯= ⎯→ = e − 00322.0( )s t ⎯⎯→ t = 615 s i −TT ∞ − 3290 Therefore, it will take 10 minutes and 15 seconds to cool the canned drink to 45°F.

Chapter 4, Solution 25.

A number of carbon steel balls are to be annealed by heating them first and then allowing them to cool slowly in ambient air at a specified rate. The time of annealing and the total rate of heat transfer from the balls to the ambient air are to be determined.

Assumptions 1 The balls are spherical in shape with a radius of ro = 4 mm. 2 The thermal properties of the balls are constant. 3 The heat transfer coefficient is constant and uniform over the entire surface. 4 The Biot number is Bi < 0.1 so that the lumped system analysis is applicable (this assumption will be verified). Properties The thermal conductivity, density, and specific heat of the balls are given to 3 be k = 54 W/m.°C, ρ = 7833 kg/m , and cp = 0.465 kJ/kg.°C. Analysis The characteristic length of the balls and the Biot number are V πD 3 6/ D 008.0 m L ===== 0013.0 m c 2 As πD 6 6 Furnace Steel balls Air, 35°C hL W/m75( 2 ° 0013.0)(C. )m Bi c == 0018.0 <= 1.0 900°C k W/m.54( ° )C Therefore, the lumped system analysis is applicable. Then the time for the annealing process is determined to be hA h W/m75 2 °C. b s === = 01584.0 s 1- c V ρρ Lc 3 p cp (7833 465)(kg/m J/kg. °C)(0.0013 m) )( −TtT − 35100 1- ∞ e −bt ⎯= ⎯→ = e − 01584.0( )ts ⎯⎯→ t 163 == 2.7s min i −TT ∞ − 35900 The amount of heat transfer from a single ball is πD 3 π 008.0( m) 3 m V ρρ === 7833( 3 )kg/m = 0021.0 kg 6 6

TTmcQ ifp =−= 0021.0(][ 465)(kg =°−° 781C)100900)(CJ/kg. J = 0.781 kJ ball)(per Then the total rate of heat transfer from the balls to the ambient air becomes

& &ballQnQ == 2500( × 781.0(balls/h) = 953,1)kJ/ball kJ/h = W543