Ttk 110 Hepa

Total Page:16

File Type:pdf, Size:1020Kb

Ttk 110 Hepa TTK 110 HEPA EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK110HEPA-TC-002-EN Table of contents You can download the current version of the operating manual and the EU declaration of conformity via the following link: Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 Information about the device................................................ 3 TTK 110 HEPA Transport and storage........................................................... 4 Assembly and installation..................................................... 5 https://hub.trotec.com/?id=39663 Operation ............................................................................... 6 Available accessories.......................................................... 11 Safety Errors and faults.................................................................. 11 Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity Maintenance ........................................................................ 13 of the device or its site of use! Technical annex................................................................... 18 Warning Disposal ............................................................................... 18 Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and / or serious injury. Save all warnings and instructions for future Notes regarding the operating manual reference. This appliance can be used by children aged from 8 years and above and persons with reduced physical, Symbols sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or Warning of electrical voltage instruction concerning use of the appliance in a safe This symbol indicates dangers to the life and health of way and understand the hazards involved. persons due to electrical voltage. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children Warning without supervision. This signal word indicates a hazard with an average • Do not use the device in potentially explosive rooms. risk level which, if not avoided, can result in serious injury or death. • Do not use the device in aggressive atmosphere. • Set the device up in an upright and stable position. Caution • Let the device dry out after a wet clean. Do not operate it This signal word indicates a hazard with a low risk when wet. level which, if not avoided, can result in minor or moderate injury. • Do not use the device with wet or damp hands. • Do not expose the device to directly squirting water. Notice • Never insert any objects or limbs into the device. This signal word indicates important information (e.g. material damage), but does not indicate hazards. • Do not cover or transport the device during operation. • Do not sit on the device. Info • This appliance is not a toy! Keep away from children and Information marked with this symbol helps you to carry animals. Do not leave the device unattended during out your tasks quickly and safely. operation. Follow the manual • Check accessories and connection parts for possible Information marked with this symbol indicates that the damage prior to every use of the device. Do not use any operating manual must be observed. defective devices or device parts. 1 Operating manual – dehumidifier TTK 110 HEPA EN • Ensure that all electric cables outside of the device are Intended use protected from damage (e.g. caused by animals). Never Use the device for dehumidifying, drying and cleaning indoor air, use the device if electric cables or the power connection while adhering to and following the technical data. are damaged! In addition, the device may also be used as a kind of clothes • The electrical connection must correspond to the dryer to dry wet laundry. specifications in chapter Technical data. Intended use comprises: • Insert the mains plug into a properly secured mains • dehumidifying, drying and cleaning the air in: socket. – living rooms, bedrooms, bathrooms or basements • Observe the device's power input, cable length and – laundries, holiday homes, camper vans, boats intended use when selecting extensions to the power • maintaining the dryness of: cable. Completely unroll extension cables. Avoid electrical – storage spaces, archives, laboratories, garages overload. – bathrooms, wash rooms, changing rooms etc. • Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Improper use Hold onto the mains plug while doing so. • Do not place the device on wet or flooded ground. • Switch the device off and disconnect the power cable from • Do not place any objects, e.g. clothing, on the device. the mains socket when the device is not in use. • Do not use the device outdoors. • Do not under any circumstances use the device if you • Any unauthorised modifications, alterations or structural detect damages on the mains plug or power cable. changes to the device are forbidden. If the supply cord is damaged, it must be replaced by the • Any operation other than as described in this manual is manufacturer, its service agent or similarly qualified prohibited. Non-observance renders all claims for liability persons in order to avoid a hazard. and guarantee null and void. Defective power cables pose a serious health risk. • When positioning the device, observe the minimum Personnel qualifications distances from walls and other objects as well as the People who use this device must: storage and operating conditions specified in the Technical • be aware of the dangers that occur when working with data chapter. electric devices in damp areas. • Ensure that the air inlet and outlet are not obstructed. • have read and understood the operating manual, especially • Ensure that the side of the device where the air inlet is the Safety chapter. found is kept free of dirt and loose objects. Maintenance tasks which require the housing to be opened • Only transport the device in an upright position with an must only be carried out by specialist companies for cooling and emptied condensation tank or drain hose. air-conditioning or by Trotec. • Discharge the collected condensate before transport and storage. Do not drink it. Health hazard! EN Operating manual – dehumidifier TTK 110 HEPA 2 Residual risks Another feature is the device's self-cleaning function. This function serves to dry the interior of the device in order to Warning of electrical voltage prevent the formation of mould or similar inside the device due Work on the electrical components must only be to residual moisture. carried out by an authorised specialist company! The device uses the principle of condensation to automatically Warning of electrical voltage dehumidify rooms. Before any work on the device, remove the mains plug The fan sucks damp room air through the air inlet, the air filter, from the mains socket! the evaporator and to the condenser located behind it. The air is Hold onto the mains plug while pulling the power cable cooled at the cold evaporator until it is below the dew point. out of the mains socket. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, Warning cooled air is slightly warmed at the condenser and blown out Dangers can occur at the device when it is used by again. The drier air thus conditioned mixes with the air in the untrained people in an unprofessional or improper way! room. The humidity in the room where the device is positioned Observe the personnel qualifications! is reduced as air constantly circulates through the device. Warning Depending on the air temperature and the relative humidity, the The device is not a toy and does not belong in the condensed water either drops continuously or only during the hands of children. defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the Warning filling level. Risk of suffocation! The device has a control panel for operating and controlling the Do not leave the packaging lying around. Children may functions. use it as a dangerous toy. Once the maximum filling level of the condensation tank is Notice reached or in case the condensation tank is not installed Do not operate the device without an inserted air filter! correctly, the condensation tank indicator light (see chapter Without the air filter, the inside of the device will be Operating elements) on the control panel is illuminated. The heavily contaminated. This could reduce the device switches off. The condensation tank indicator light only performance and result in damage to the device. goes out again once the emptied condensation tank is reinserted. Behaviour in the event of an emergency Optionally, the condensed water can be drained by attaching a 1. In an emergency, disconnect the device from the mains hose at the condensation connection. feed-in: Switch the device off and disconnect the power cable from the mains socket. Hold onto the mains plug The device can reduce the relative humidity of a room to approx. while doing so. 40 %. 2. Do not reconnect a defective device to the mains. The device provides additional assistance for drying wet laundry or clothing in living or working spaces. Information about the device Because of the heat radiation generated during operation, the room temperature
Recommended publications
  • How to Comply with CDC Guidelines
    1101 W. 13th St, Riviera Beach, Florida Phone: 561.848.1826 https://www.rgf.com/rgf-biocontrols How to comply with CDC Guidelines OVERVIEW Sections of text are extracted directly from the Federal Register Vol. 59, No. 208, 10/28194, to compile this pamphlet. This is not meant to be a substitute for the Guidelines, but a general overview of specific sections relevant to RGF BioControls and its products. Click here for a link: https://www.cdc.gov/mmwr/preview/mmwrhtml/rr5417a1.htm OUR MISSION We believe, once you understand the new CDC guidelines, you’ll understand why our products offer you the best means of compliance. This is based upon a design philosophy that each piece of equipment is designed to satisfy a particular problem and each problem can be satisfied by an individual or combination of products that complement each other. CDC ON NEGATIVE PRESSURE "To control the direction of airflow between the room and adjacent areas, thereby preventing contaminated air from escaping from the room into other areas of the facility. The direction of air flow is controlled by creating a lower (negative) pressure in the area into which the flow of air is desired. For air to flow from one area to another, the air pressure in the two areas must be different. Air will flow from a higher pressure area to a lower pressure area. " HOW RGF BIOCONTROLS CREATES NEGATIVE PRESSURE Our MICROCON ® ExC7 utilizes HEPA filtration and UV light (option) for various room exhaust options. Wall, window or ceiling mounted, they direct air to either outside, back to return air system or corridor.
    [Show full text]
  • ASHRAE Position Document on Filtration and Air Cleaning
    ASHRAE Position Document on Filtration and Air Cleaning Approved by ASHRAE Board of Directors January 29, 2015 Reaffirmed by Technology Council January 13, 2018 Expires January 23, 2021 ASHRAE 1791 Tullie Circle, NE • Atlanta, Georgia 30329-2305 404-636-8400 • fax: 404-321-5478 • www.ashrae.org © 2015 ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. COMMITTEE ROSTER The ASHRAE Position Document on Filtration and Air Cleaning was developed by the Society's Filtration and Air Cleaning Position Document Committee formed on January 6, 2012, with Pawel Wargocki as its chair. Pawel Wargocki, Chair Dean A. Saputa Technical University of Denmark UV Resources Kongens Lyngby, Denmark Santa Clarita, CA Thomas H. Kuehn William J. Fisk University of Minnesota Lawrence Berkeley National Laboratory Minneapolis, MN Berkeley, CA H.E. Barney Burroughs Jeffrey A. Siegel Building Wellness Consultancy, Inc. The University of Toronto Johns Creek, GA Toronto, ON, Canada Christopher O. Muller Mark C. Jackson Purafil Inc. The University of Texas at Austin Doraville, GA Austin, TX Ernest A. Conrad Alan Veeck BOMA International National Air Filtration Association Washington DC Virginia Beach, VA Other contributors: Dean Tompkins Madison, WI for his contribution on photocatalytic oxidizers Paul Francisco, Ex-Officio Cognizant Committee Chair Environmental Health Committee University of Illinois Champaign, IL ASHRAE is a registered trademark in the U.S. Patent and Trademark Office, owned by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. © 2015 ASHRAE (www.ashrae.org). For personal use only.
    [Show full text]
  • Indoor Air Quality Products Offering Healthy Home Solutions
    Indoor Air Quality Products Offering Healthy Home Solutions Carrier clears the air for enhanced indoor comfort What You Can Expect From Carrier Innovation, efficiency, quality: Our Carrier® Healthy Home Solutions offers superior control over the quality of your indoor air and as a result, improved comfort. From air purification and filtration to humidity control, ventilation and more, these products represent the Carrier quality, environmental stewardship and lasting durability that have endured for more than a century. In 1902, that’s the year a humble but determined engineer solved one of mankind’s most elusive challenges – controlling indoor comfort. A leading engineer of his day, Dr. Willis Carrier would file more than 80 patents over the course of his career. His genius would enable incredible advancements in health care, manufacturing processes, food preservations, art and historical conservation, indoor comfort and much more. Carrier’s foresight changed the world forever and paved the way for over a century of once-impossible innovations. Designed with Your Comfort in Mind Carrier® Healthy Home Solutions represents years of design, development and testing with one goal in mind – maximizing your family’s comfort. Along the way, we have taken the lead with new technologies that deliver the superior performance you demand while staying ahead of industry trends and global initiatives. With innovations like Captures & Kills™ technology and superior humidity and airflow control, whatever your need, Carrier has a solution that’s perfectly tailored for you. 2 Ready to Clear the Air? The EPA has found that indoor levels of many air pollutants are often higher than outdoor levels.
    [Show full text]
  • Fast Facts (PDF)
    FAST FACTS According to the National Fire Protection Association, the leading factor contributing to home heating fires (30%) was mainly due to having a dirty chimney (i.e., creosote buildup). Heating equipment (including wood stoves) is the second leading cause of home fires, and third leading cause of home fire deaths. Most fireplace and chimney fires are caused by creosote buildup, and could be prevented. EPA believes there are approximately 13 million fireplaces, 250,000 hydronic heaters, and 8.5 million wood stoves in use nationwide. Five million (57 percent) of the nation’s wood stoves are older, inefficient devices. EPA estimates that if all of the old wood stoves in the United States were replaced with cleaner- burning hearth appliances, an estimated $56-126 billion in health benefits per year would be realized. Smoke from wood-burning stoves and fireplaces contain a mixture of harmful gases and particle matter (PM2.5). Breathing these small particles can cause asthma attacks and severe bronchitis, aggravate heart and lung disease, and may increase the likelihood of respiratory illnesses. Changing out one old dirty, inefficient wood stove is equivalent to the PM2.5 reduction of taking five old diesel trucks off the road. The benefits of replacing old wood stoves and fireplaces: • Saves money, fuel, time, and resources • Up to 50 percent more energy efficient, uses 1/3 less wood • Cuts creosote build-up in chimneys that helps reduce the risk of fire • Reduces PM2.5 indoors and out After start-up, a properly installed, correctly used EPA-certified wood stove should be smoke free.
    [Show full text]
  • HEPA) Filter - Ultra Low Penetration Air (ULPA) Filter (Also Referred to As Extended Media
    EPA-452/F-03-023 Air Pollution Cocntrol Technology Fact Sheet Name of Technology: Paper/Nonwoven Filter - High Efficiency Particle Air (HEPA) Filter - Ultra Low Penetration Air (ULPA) Filter (also referred to as Extended Media) Type of Technology: Control Device - Capture/Disposal Applicable Pollutants: Submicron Particulate Matter (PM) greater than or equal to 0.3 micrometer (µm) in aerodynamic diameter, and PM greater than or equal to 0.12 µm in aerodynamic diameter that is chemically, biologically, or radioactively toxic; hazardous air pollutants (HAPs) that are in particulate form, such as most metals (mercury is the notable exception, as a significant portion of emissions are in the form of elemental vapor). Achievable Emission Limits/Reductions: HEPA and ULPA filters are classified by their minimum collection efficiency. Many international standards and classes currently exist for high efficiency filters (Osborn, 1989). In general, HEPA and ULPA filters are defined as having the following minimum efficiency rating (Heumann, 1997): HEPA: 99.97% efficiency for the removal of 0.3 µm diameter or larger PM, ULPA: 99.9995% efficiency for the removal of 0.12 µm diameter or larger PM. Some extended media filters are capable of much higher efficiencies. Commercially available filters can control PM with 0.01 µm diameter at efficiencies of 99.99+% and PM with 0.1 µm diameter at efficiencies of 99.9999+% (Gaddish, 1989; Osborn, 1989). Several factors determine HEPA and ULPA filter collection efficiency. These include gas filtration, velocity, particle characteristics, and filter media characteristics. In general, the collection efficiency increases with increasing filtration velocity and particle size.
    [Show full text]
  • Model 1830, 1850 & 1850W Dehumidifier Owner's Manual
    Model 1830, 1850 & 1850W Dehumidifier Owner’s Manual PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER Installed by: _________________________________ Installer Phone: _______________________ Date Installed: _______________ ON/OFF button Up/Down Dehumidifer Control Outlet used to turn buttons used to dehumidifier on change humidity and off setting MODE button used for optional ventilation feature Inlet Filter Access Drain Power Door Switch 90-1874 WHOLE HOME Dehumidification The Aprilaire® Dehumidifier controls the humidity level in your entire home. A powerful blower inside the dehumidifier draws air into the cabinet, filters the air and removes moisture, then discharges the dry air into the HVAC system or dedicated area of the home. Inside the cabinet, a sealed refrigeration system removes moisture by moving the air through a series of tubes and fins that are kept colder than the dew point of the incoming air. The dew point is the temperature at which moisture in the air will condense, much like what occurs on the outside of a cold glass on a hot summer day. The condensed moisture drips into the dehumidifier drain pan to a drain tube routed to the nearest floor drain or condensate pump. After the moisture is removed, the air moves through a second coil where it is reheated before being sent back into the home. The air leaving the dehumidifier will be warmer and drier than the air entering the dehumidifier. SETTING THE DESIRED HUMIDITY LEVEL The dehumidifier on-board control will display the humidity setting when not running, and ENERGY SavinGS TIPS displays the measured humidity when running. Energy Savings Tip #1: Adjust the humidity setting to be as high as is comfortable to reduce dehumidifier run time.
    [Show full text]
  • DEHUMIDIFIER with BUILT-IN PUMP
    DEHUMIDIFIER with BUILT-IN PUMP MODELS: SD-52PE / SD-72PE INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference. CONTENTS SAFETY PRECAUTUIONS…...……………………………………………………………2 ELECTRICAL INFORMATION .……………………………………………………………3 CONTROL PANEL ….………………………………………………………………………4 FEATURES ………….……………………………………………………………………….5 IDENTIFICATION OF PARTS …………………………….……………………………….6 OPERATING THE UNIT ………..………………………….……………………………….7 WATER DRAINAGE ……….………..…………………………………………………….8 CARE AND MAINTENANCE ………..………………………………………………….10 TECHNICAL SPECIFICATIONS ……………………….………………………………11 TROUBLE SHOOTING …………………………………………………………………..11 SOCIABLE REMARK DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at free of charge to the user. B) The manufacturer will take back the old appliance for disposal at free of charge to the user. C) As old products contain valuable resources, they may be sold to scrap metal dealers. Wild disposal of waste in forest and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain. 1 BEFORE YOU USE YOUR DEHUMIDIFIER , PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY. SAFETY PRECAUTIONS To prevent injury and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damages. The seriousness is classified by the following indications: WARNING: This symbol indicates the possibility of death or serious injury. CAUTION: This symbol indicates the possibility of injury or damage to property. ------------------------------------------ WARNING --------------------------------------------------- 1. Do not exceed the rating of the power outlet or connection device.
    [Show full text]
  • A Hybrid Air Purifier and Dehumidifier for the Best Possible Indoor Air
    AD20 Hybrid / Air purifier & Dehumidifier A hybrid air purifier and dehumidifier for the best possible indoor air. & ER D AN EH Wood´s AD20 hybrid is a revolutionary innovation that LE UM C ID IF I R E I R E A CL AN E R A R I R I R E I A F combines Wood´s high standards for energy-effecient I D I C M L E U A H N E E D R & and reliable dehumidification, with Wood´s unique & R E N A E D L SWEDISH TECHNIQUE E C N U M I R D I I A F I E R Swedish filtration system and give you the best possible indoor air. Thanks to the patented filter system Active ION HEPA, manufactured in Sweden, AD20 Hybrid gives you an effective air cleaning-without compromising on power consumption or noise levels. Wood’s AD-20 Hybrid Specifications dehumidification AD20 Hybrid is reliable, efficient and energy-saving. Max. working area 100 m² Recommended area 2 - 60 m² AD20 Hybrid protects against moisture and mold dam- Capacity at 20ºC & 70% RF 10,6 litres/day age and also serve you with an air purifier in the same Capacity at 35ºC & 80% RF 20 litres/day Power at 27ºC & 60% RF 260 W machine. AD20 Hybrid is one of the smartest hybrid Power at 30ºC & 80% RF 310 W dehumidifiers / air purifiers on the market. Fan speeds 4 Airflow 100-200 m³/h Speed 1 100 m³/h Speed 2 130 m³/h Advantages: Speed 3 160 m³/h Speed 4 200 m³/h • Powerful and energy efficient dehumidification.
    [Show full text]
  • Cabin Air Quality Brief
    Briefing paper Cabin air quality – Risk of communicable diseases transmission The overall risk of contracting a disease from an ill person onboard an airplane is similar to that in other confined areas with high occupant density, such as a bus, a subway, or movie theatre for a similar time of exposure. anywhere where a person is in close contact with others. That said, the risk on airplanes is probably lower than in many confined spaces because modern airplanes have cabin air filtration systems equipped with HEPA filters. HEPA or high efficiency particulate air filters have similar performance to those used to keep the air clean in hospital operating rooms and industrial clean rooms. These filters are very effective at trapping microscopic particles as small as bacteria and viruses. HEPA filters are effective at capturing greater than 99 percent of the airborne microbes in the filtered air. Filtered, recirculated air provides higher cabin humidity levels and lower particulate levels than 100% outside air systems. The cabin air system is designed to operate most efficiently by delivering approximately 50 percent outside air and 50 percent filtered, recirculated air. This normally provides between 15 to 20 cubic feet of total air supply per minute per person in economy class. The total air supply is essentially sterile and particle-free. Cabin air circulation is continuous. Air is always flowing into and out of the cabin. Total airflow to the cabin is supplied at a bulk flow rate equivalent to 20 to 30 air changes per hour. This provides temperature control and minimizes temperature gradients within the cabin.
    [Show full text]
  • Dehumidifiers' Common Phenomenon and Troubleshooting Manual
    Dehumidifiers’ Common Phenomenon and Troubleshooting Manual AlorAir Solutions,Inc Web: www.alorair.com E-mail: [email protected] Restoration&Moisture&Ventilation Dehumidifiers’ Common Phenomenon and Troubleshooting Manual Welcome to Alorair company. Alorair focuses mainly on Dehumidifier’s Common Phenomenon and Troubleshooting.. inner air quality solutions with quite professional dehumidifiers’ LGR ............................................................... .. PAGE 01-03 technology, SLGR technology, super efficient air mover and air scrubber. As the staff train file and customers after-sale instruction, Dehumidifiers’ Common Phenomenon and Troubleshooting manual aims to bring a serial of expertise suggestions in facing with confused Error codes............................................................................ dehumidifier operation errors. ................................................................ PAGE 03-06 This manual contains three parts: 1).Dehumidifiers’ Common Phenomenon and Troubleshooting FAQ........................................................................................ 2). Error codes .................................................................. PAGE 06 3). FAQ Please refer to according contents for your reference needs. Humidity sensor failure Replace the humidity sensor Dehumidifiers’ Common Phenomenon Frequent starting of The humidity sensor is influenced by the moisture Adjust the position of the sensor to the right unit from evaporator position to avoid interference and Troubleshooting Humidity
    [Show full text]
  • (HDH) Desalination System with Air-Cooling Condenser and Cellulose Evaporative Pad
    water Article Humidification–Dehumidification (HDH) Desalination System with Air-Cooling Condenser and Cellulose Evaporative Pad Li Xu * , Yan-Ping Chen, Po-Hsien Wu and Bin-Juine Huang Mechanical Engineering Department, National Taiwan University, 708 Engineering Building, No.1 Section 4 Roosevelt Rd., Taipei 106, Taiwan; [email protected] (Y.-P.C.); [email protected] (P.-H.W.); [email protected] (B.-J.H.) * Correspondence: [email protected] Received: 27 October 2019; Accepted: 30 December 2019; Published: 2 January 2020 Abstract: This paper presents a humidification–dehumidification (HDH) desalination system with an air-cooling condenser. Seawater in copper tubes is usually used in a condenser, but it has shown the drawbacks of pipe erosion, high cost of the copper material, etc. If air could be used as the cooling medium, it could not only avoid the above drawbacks but also allow much more flexible structure design of condensers, although the challenge is whether the air-cooing condenser can provide as much cooling capability as water cooling condensers. There is no previous work that uses air as cooling medium in a condenser of a HDH desalination system to the best of our knowledge. In this paper we designed a unique air-cooling condenser that was composed of closely packed hollow polycarbonate (PC) boards. The structure was designed to create large surface area of 13.5 m2 with the volume of only 0.1 m3. The 0.2 mm thin thickness of the material helped to reduce the thermal resistance between the warm humid air and cooling air. A fan was used to suck the ambient air in and out of the condenser as an open system to the environment.
    [Show full text]
  • 13-08 the Wild Center Renewable Heating Demonstration
    New York State Energy Research and Development Authority The Wild Center Renewable Heating Demonstration: High-Efficiency, Commercial-Scale, Wood-Pellet Boiler Integrated with a Solar Thermal System Final Report March 2013 NYSERDA Report 13-08 NYSERDA’s Promise to New Yorkers: NYSERDA provides resources, expertise, and objective information so New Yorkers can make confident, informed energy decisions. Our Mission: Advance innovative energy solutions in ways that improve New York’s economy and environment. Our Vision: Serve as a catalyst—advancing energy innovation and technology, transforming New York’s economy, empowering people to choose clean and efficient energy as part of their everyday lives. Our Core Values: Objectivity, integrity, public service, partnership, and innovation. Our Portfolios NYSERDA programs are organized into five portfolios, each representing a complementary group of offerings with common areas of energy-related focus and objectives. Energy Efficiency and Renewable Energy Deployment Energy and the Environment Helping New York State to achieve its aggressive energy efficiency Helping to assess and mitigate the environmental impacts and renewable energy goals – including programs to motivate of energy production and use in New York State– including increased efficiency in energy consumption by consumers (residential, environmental research and development, regional initiatives commercial, municipal, institutional, industrial, and transportation), to improve environmental sustainability, and West Valley to increase
    [Show full text]