Arxiv:2003.10672V1 [Astro-Ph.IM] 24 Mar 2020
Total Page:16
File Type:pdf, Size:1020Kb
View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Caltech Authors A frequency-dependent squeezed vacuum source for broadband quantum noise reduction in advanced gravitational-wave detectors Yuhang Zhao1;2, Naoki Aritomi3, Eleonora Capocasa1,∗ Matteo Leonardi1,y Marc Eisenmann4, Yuefan Guo5, Eleonora Polini4, Akihiro Tomura6, Koji Arai7, Yoichi Aso1, Yao-Chin Huang8, Ray-Kuang Lee8, Harald L¨uck9, Osamu Miyakawa10, Pierre Prat11, Ayaka Shoda1, Matteo Tacca5, Ryutaro Takahashi1, Henning Vahlbruch9, Marco Vardaro5;12;13, Chien-Ming Wu8, Matteo Barsuglia11, and Raffaele Flaminio4;1 1National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo, 181-8588, Japan 2The Graduate University for Advanced Studies(SOKENDAI), 2-21-1, Osawa, Mitaka, Tokyo 181-8588, Japan 3 Department of Physics, University of Tokyo, 7-3-1 Hongo, Tokyo, 113-0033, Japan 4Laboratoire d'Annecy-le-Vieux de Physique des Particules (LAPP), Universit Savoie Mont Blanc, CNRS/IN2P3, F-74941 Annecy-le-Vieux, France 5Nikhef, Science Park, 1098 XG Amsterdam, Netherlands 6The University of Electro-Communications 1-5-1 Chofugaoka, Chofu, Tokyo 182-8585, Japan 7LIGO, California Institute of Technology, Pasadena, California 91125, USA 8Institute of Photonics Technologies, National Tsing-Hua University, Hsinchu 300, Taiwan 9Institut f¨urGravitationsphysik, Leibniz Universit¨atHannover and Max-Planck-Institut f¨ur Gravitationsphysik (Albert-Einstein-Institut), Callinstraße 38, 30167 Hannover, Germany 10Institute for Cosmic Ray Research (ICRR), KAGRA Observatory, The University of Tokyo, Kamioka-cho, Hida City, Gifu 506-1205, Japan 11Laboratoire Astroparticule et Cosmologie (APC), 10 rue Alice Domon et L´eonieDuquet, 75013 Paris, France 12Institute for High-Energy Physics, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, Netherlands and 13Universit di Padova, Dipartimento di Fisica e Astronomia, I-35131 Padova, Italy (Dated: March 25, 2020) The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300 m long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz. INTRODUCTION nature of light. It manifests itself in two components: quantum shot noise, dominating at high frequencies of Gravitational-wave astronomy, started in 2015 with the detector spectrum and quantum radiation pressure the first detection of a black hole merger by LIGO [1], noise, dominating at low frequencies. In 1981 Carlton has rapidly become a mature research field. After the Caves clarified that quantum noise is originated by quan- groundbreaking observation of the binary neutron star tum vacuum fluctuations entering the interferometer an- tisymmetric port [9]. He also suggested that quantum arXiv:2003.10672v1 [astro-ph.IM] 24 Mar 2020 coalescence GW170817 [2]and the publication of the first gravitational-wave sources catalog [3], the network of ad- noise could be reduced by replacing ordinary vacuum vanced interferometric detectors (comprised of the two states with the so-called squeezed vacuum states, whose Advanced LIGO [4] and Advanced Virgo [5]) is now per- noise is reshaped in order to reduce it in one quadrature forming a third period of data taking (O3), detecting and increase it in the orthogonal one, in accordance with several candidates per month and sending open alerts to Heisenberg's uncertainty principle. A squeezed state can the astronomical community [6]. The Japanese detector, be represented in the quadrature plane as an ellipse, char- KAGRA [7], is about to join the network and is expected acterized by two frequency-dependent parameters: the to be followed by a fifth detector, LIGO India, in 2024 squeezing magnitude (the ratio of the ellipse axes with [8]. respect to the unsqueezed state) and the squeezing angle (the ellipse orientation). One of the main limitations to the detector sensitiv- ity is quantum noise, which originates from the quantum More than thirty years of experimental developments 2 were needed before such technology could be integrated EXPERIMENTAL SETUP in the detectors [10, 11]. Since the beginning of O3, in April 2019, both Advanced Virgo and Advanced LIGO feature a frequency-independent squeezing source which The experiment is realized at the National Astronom- is enhancing their performances [12], bringing an increase ical Observatory of Japan (NAOJ), using the infrastruc- in the detection rate of up to 50% [13]. However, the ture of the former TAMA 300 interferometer [23]. squeezed vacuum currently used in advanced detectors cannot reduce simultaneously both quantum noise com- The experimental setup, sketched in Fig. 1, consists of ponents. The increase of radiation pressure noise due to two parts: a source of frequency-independent squeezed frequency-independent squeezing has been recently ob- vacuum and a suspended filter cavity. The two are con- served in both Advanced Virgo and Advanced LIGO nected by an in-vacuum injection system, including sus- [14, 15]. The reason is the opto-mechanical coupling with pended mirrors, which couples the squeezing into the fil- the suspended test masses, which induces a rotation of ter cavity. A detailed description of the cavity and the the squeeze ellipse by 90◦ across the frequency spectrum, injection apparatus can be found in [24]. so that the noise-reduced quadrature cannot be aligned with the gravitational-wave signal at all frequencies [16]. Even if the current degradation of the sensitivity induced at low frequency is barely observable due to the presence 1064 nm 532 nm Squeezed Vacuum of technical noises and to the limited amount of power Coherent Control OPO length control used, it is expected to become more and more detrimen- Suspended Mirror Faraday Isolator tal as the detectors approach their design sensitivity. EOM PZT actuated mirror Photodiode A possible solution to reduce quantum noise in the whole spectrum is the injection of frequency-dependent Fiber based PLL PBS BS squeezed vacuum, where the squeeze ellipse rotates as In-vacuumm FilterCavity 300 a function of frequency, to counteract the rotation in- duced by the interferometer. Such reduction is opti- mal if the rotation is at the crossover frequency be- tween the radiation-pressure dominated and the shot- noise dominated regions, around 30-70 Hz for advanced gravitational-wave detectors. In-vacuum Injection Telescope Homodyne The interaction of a frequency-independent squeezed state with an optical Fabry-Perot resonator, referred to as filter cavity, is able to induce such rotation of the squeeze ellipse [17]. In the past, squeeze ellipse rotation AOM has been realized in the MHz [18] and kHz [19] regions using rigid, meter-scale filter cavities. OPO MZ In this letter, we report the first demonstration of a frequency-dependent squeezed vacuum source able to re- SHG duce quantum noise of advanced gravitational-wave de- tectors in their whole observation bandwidth. The exper- iment uses a filter cavity capable of rotating the squeez- AUX2 ing ellipse below 100 Hz, in the region needed for ad- AUX1 vanced detectors. The validation of this technology using Main Laser a 300 m filter cavity is especially significant as KAGRA, In-air Squeezed Vacuum Source and Filter Cavity control Advanced LIGO and Advanced Virgo, all plan to inte- grate filter cavities of comparable length in the upcoming FIG. 1. Schematic diagram of the experimental setup. The squeezed vacuum beam is produced by the OPO and injected upgrading phase [20, 21]. into the filter cavity through the in-vacuum injection tele- scope. The reflected frequency-dependent squeezing is re- Concurrent with, and independent of, this work, a sim- jected by the in-vacuum Faraday and characterized by the ilar experiment, carried out in the US with a 16 m filter homodyne detector. The green beam produced by the SHG cavity, shows a 30 Hz rotation frequency and includes is used to pump the OPO and as auxiliary beam for the con- a new control system, capable of meeting the stringent trol of the filter cavity. noise requirements of LIGO and other gravitational-wave detectors [22]. 3 Frequency-independent squeezed vacuum source residual length noise [31, 32]. The frequency at which the rotation takes place depends on the cavity linewidth, The in-air squeezed vacuum source, assembled specif- which is inversely proportional to its length and finesse. ically for this experiment, follows the design of the Given the 300 m length of the cavity, the finesse is chosen GEO600 squeezer [25]. The core part is the optical to be 4400 at 1064 nm wavelength, to provide a squeeze parametric oscillator (OPO): a linear hemilithic cavity ellipse rotation at approximately 75 Hz, corresponding hosting a PPKTP (Periodically Poled Potassium Titanyl to an optimal quantum noise reduction for KAGRA [32]. Phosphate) crystal in which the squeezed vacuum is pro- Since cavity losses are a major threat to squeezing [31], duced through a parametric down-conversion process. requirements on the mirror surface quality were first de- This requires a pump beam at twice the squeezing fre- termined by numerical simulations, using realistic mirror quency, which is produced by injecting a 1064 nm laser maps [32].