Lab Equipment 13

Total Page:16

File Type:pdf, Size:1020Kb

Lab Equipment 13 Directions: Identify each lab equipment. ID: C LAB EQUIPMENT TEST 13. 30. 34. 33. 21. 17. 42. 26. 19. 35. 14. 31. 28. 40. 29. 39. 24. 32. 44. 16. 22. 36. 23. 20. 38. 37. 25. 45. 41. 27. 18. 15. 43. HOW TO CORRECTLY FOLD FILTER PAPER FOR FUNNEL Chemistry Test: Lab Equipment Identification Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. What lab equipment is used to safely and conveniently perform reactions that require heating using a Bunsen Burner? A. B. C. D. Crucible Ring Stand Dropping Pipet Cleaning Brush 2. What lab equipment holds solids or liquids that may release gases during a reaction or that are likely splatter if stirred or heated. A. B. C. D. Erlenmeyer Flask Beaker Florence Flask Wide Mouthed Bottle 3. What lab equipment is used for holding and organizing test tubes on the laboratory counter? Also a good place to store test tubes while they dry. A. B. C. D. Buret Clamp Clamp Holder Extension Clamp Test Tube Rack 4. What lab equipment is rarely used by first year chemist and is used to mix chemicals that may splatter? It has a narrow neck to prevent splatter? A. B. C. D. Erlenmeyer Flask Beaker Florence Flask Wide Mouthed Bottle 5. What lab equipment is used for the heating of stable solid compounds and elements? Also used to seperate a solid suspended in a liquid by boiling away the liquid. A. B. C. D. Watch Glass Volumetric Flask Evaporating Dish Wash Bottle 6. What lab equipment is used to measure volumes of liquid? A. Graduated Cylinder B. Separatory Funnel C. Test Tubes D. Volumetric Pipet 7. What lab equipment is used to manually stir solutions? A. B. C. D. Thermometer Forceps Stirring Rod Striker 8. What lab equipment is used to collect large amounts of gas and is done so by the displacement of water? A. B. C. D. Erlenmeyer Flask Beaker Florence Flask Wide Mouthed Bottle 9. What long tube with a small diameter is used to measure and deliver exact volumes of liquids? It is designed to measure different amounts of the liquid and uses a bulb to draw the liquid into it? A. B. C. D. Buret Graduated Pipet Condenser Funnel 10. What lab equipment is used to provide heat for experimentation? A. B. C. D. Test Tube Rack Mortar and Pestle Wire Gauze Bunsen Burner 11. What lab equipment is used to move a crucible from the heat? A. B. C. D. Crucible Tongs Test Tube Tongs Beaker Tongs Triangle 12. What lab equipment holds solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated? A. Erlenmeyer Flask B. Beaker C. Florence Flask D. Wide Mouthed Bottle .
Recommended publications
  • AOAC Official Method 2011.25 Insoluble, Soluble, and Total Dietary Fiber in Foods
    AOAC Official Method 2011.25 supplies/fisherbrand.html) or 250 mL polypropylene bottles with Insoluble, Soluble, and Total Dietary Fiber in Foods polypropylene caps. Enzymatic-Gravimetric-Liquid Chromatography (c) Fritted crucible.—Gooch, fritted disk, Pyrex® 50 mL, First Action 2011 pore size, coarse, ASTM 40–60 µm (Corning No. 32940-50C® [Applicable to plant material, foods, and food ingredients or equivalent; http://www.labplanet.com/corning-crucible-gooch- consistent with CODEX Alimentarius Commission high-c-50-ml-32940-50c.html). Prepare four for each sample as Definition adopted in 2009 and modified slightly in 2010 follows: Ash overnight at 525°C in muffle furnace. Cool furnace to (ALINORM 09/32/REP and ALINORM 10/33/REP, respectively), 130°C before removing crucibles to minimize breakage. Remove including naturally occurring, isolated, modified, and synthetic any residual Celite and ash material by using a vacuum. Soak in 2% polymers meeting that definition.] cleaning solution, C(i), at room temperature for 1 h. Rinse crucibles See Tables 2011.25A–H for the results of the interlaboratory with water and deionized water. For final rinse, use 15 mL acetone study supporting acceptance of the method. and air dry. Add approximately 1.0 g Celite to dried crucibles and A. Principle dry at 130°C to constant weight. Cool crucible in desiccators for approximately 1 h and record mass of crucible containing Celite. A method is described for the measurement of insoluble, (d) Filtering flask.—Heavy-walled, 1 L with side arm. soluble, and total dietary fiber (IDF, SDF, and TDF, respectively), (e) Rubber ring adaptors.—For use to join crucibles with inclusive of the resistant starch (RS) and the water:alcohol soluble filtering flasks.
    [Show full text]
  • Extraction of Water Samples by Separatory Funnel 1. Scope And
    Alpha Analytical, Inc. ID No.:2165 Facility: Mansfield Revision 8 Department: Organic Extractions Published Date:8/9/2013 10:58:53 AM Title: Extraction of Water Samples by Separatory Funnel 3510 Page 1 of 11 Extraction of Water Samples by Separatory Funnel References: EPA 3510C, SW-846, Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, EPA SW-846, Update III, 1997. Method 8081B , Reference: SW-846, Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, EPA SW-846, Update IV, February 2007. Method 8082A , Reference: SW-846, Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, EPA SW-846, Update IV, February 2007. Method 8270D , Reference: SW-846, Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, EPA SW-846, Update IV, February 2007 1. Scope and Application Matrices: This method is applicable to aqueous samples. Definitions: Refer to Alpha Analytical Quality Manual. This method describes the procedure for extracting water-insoluble and lightly water-soluble organic compounds from aqueous samples. The method also describes concentration techniques suitable for preparing the extract for the various determinative methods listed in Table 1. The data report packages present the documentation of any method modification related to the samples tested. Depending upon the nature of the modification and the extent of intended use, the laboratory may be required to demonstrate that the modifications will produce equivalent results for the matrix. Approval of all method modifications is by one or more of the following laboratory personnel before performing the modification: Area Supervisor, Department Supervisor, Laboratory Director, or Quality Assurance Officer. This method is restricted to use by or under the supervision of trained analysts.
    [Show full text]
  • Laboratory Glassware N Edition No
    Laboratory Glassware n Edition No. 2 n Index Introduction 3 Ground joint glassware 13 Volumetric glassware 53 General laboratory glassware 65 Alphabetical index 76 Índice alfabético 77 Index Reference index 78 [email protected] Scharlau has been in the scientific glassware business for over 15 years Until now Scharlab S.L. had limited its sales to the Spanish market. However, now, coinciding with the inauguration of the new workshop next to our warehouse in Sentmenat, we are ready to export our scientific glassware to other countries. Standard and made to order Products for which there is regular demand are produced in larger Scharlau glassware quantities and then stocked for almost immediate supply. Other products are either manufactured directly from glass tubing or are constructed from a number of semi-finished products. Quality Even today, scientific glassblowing remains a highly skilled hand craft and the quality of glassware depends on the skill of each blower. Careful selection of the raw glass ensures that our final products are free from imperfections such as air lines, scratches and stones. You will be able to judge for yourself the workmanship of our glassware products. Safety All our glassware is annealed and made stress free to avoid breakage. Fax: +34 93 715 67 25 Scharlab The Lab Sourcing Group 3 www.scharlab.com Glassware Scharlau glassware is made from borosilicate glass that meets the specifications of the following standards: BS ISO 3585, DIN 12217 Type 3.3 Borosilicate glass ASTM E-438 Type 1 Class A Borosilicate glass US Pharmacopoeia Type 1 Borosilicate glass European Pharmacopoeia Type 1 Glass The typical chemical composition of our borosilicate glass is as follows: O Si 2 81% B2O3 13% Na2O 4% Al2O3 2% Glass is an inorganic substance that on cooling becomes rigid without crystallising and therefore it has no melting point as such.
    [Show full text]
  • Single Pass Cooling Systems
    A Sustainable Alternative to Single Pass Cooling Systems Amorette Getty, PhD Co-Director, LabRATS What is Single Pass Cooling? ● Used for distillation/reflux condensers, ice maker condensers, autoclaves, cage washers… ● Use a continuous flow of water from faucet to sewer o 0.25-2 gallons per minute, o up to 1,000,000 gallons of water/year if left on continuously Single Pass Cooling: Support ● “U.S. Environmental Protection Agency has ranked the elimination of single-pass cooling systems #4 on its list of top ten water management techniques” -Steve Buratto, Chair of Chemistry and Biochemistry department NOT Just a Sustainability Issue! California Nanosystems Institute (CNSI) flood in a second-floor laboratory in July, 2014. Water ran at ~1-2 gallons per minute for 6-10 hours, overflowing into a ground floor electron microscopy lab CNSI Flood Losses ● $ 2.2 Million in custom built research equipment ● Research shutdown for 4 months ● over 200 hours of staff time ● Insurance no longer covering this type of incident again Campus Responses to the Incident • CNSI ban on single pass cooling systems • TGIF grant financial incentive for optional change of single replacement systems • Chemistry and Material Research Laboratory (MRL) • Additional Grants being sought • Conversation at Campus and UC-level to regulate and replace these types of systems. Seeking Allies… ● “The replacement of single-pass cooling systems with closed-loop and water free systems would save water and represent a major advance in the sustainability efforts of the campus.” -Steve Buratto, Chair of Chemistry and Biochemistry department Barriers to Replacement ● “...major obstacle to replacing the single-pass cooling systems with closed-loop and water- free systems is cost.
    [Show full text]
  • Table of Contents
    Manufacturing Science and Technology, ICMST2011 ISBN(softcover): 978-3-03785-295-8 ISBN(eBook): 978-3-03813-758-0 Table of Contents Preface and Organizing Committee Chapter 1: Computer-Aided Manufacturing Automatic On-Line Detection and Sorting System Design and Implementation for Paper- Making Printing R.X. Sun, L. Gao, J. Kang, P.P. Huang, Y. Tian and X.F. Chen 3 Design and Realization of Monitoring System for Multiway pH Value R.X. Sun, P.P. Huang, N. Ran, J. Kang, X.F. Chen and Y. Tian 6 The CAD/CAM of Hydraulic Valve Block Based on Pro/Engineer W.L. Wu, X.J. Jin and K.L. Xing 12 Design and Implementation of a Computer Vision Based Inspection System Using CUDA Y. Shi, A.G. Li and L. Wang 18 Structure Reverse Design and CFD Analysis on Agitated Flow Field of Submersible Mixer W.X. Xu and M.Y. Fan 25 Robust State-Feedback Controller Design for Uncertainty Singular Systems L.M. Liang, F.L. Weng and Y.C. Ding 32 An Estimation Approach Based on Predictive Filtering to Missile Guidance Y.Y. Song, W.C. Chen and X.L. Yin 38 Controller Design for Spinning Missile with the Actuator Limit F. Liu and W.C. Chen 45 The Time-Delay Study on Vehicle Active Control Suspension F.R. Kou 52 The Research on High-Voltage Transmission Line Relay Protection Setting Related to OLTC Anti-Icing S.Q. Liu, H. Wang, X.M. Li and D.X. Zhou 59 Development of Islanding Detection Based on Power Controlling for Grid-Connected of Dispersed Power Generation W.M.
    [Show full text]
  • FS/2018 ORGANIC CHEMISTRY I LAB CHEM 226 (2219) Instructor
    FS/2018 ORGANIC CHEMISTRY I LAB CHEM 226 (2219) Instructor: Terry Bone 120-B Schrenk Hall [email protected] 341-4820 http://www.mst.edu/~tbone 9:00-10:00, Tu-Th, or by appt. Cynthia Bolon 213 Schrenk Hall [email protected] 341-4439 OBJECTIVES: Course objectives are to develop facility with performing laboratory techniques involving the handling of organic chemicals safely and the keeping of proper records of experiments conducted in the laboratory. Crystallization, distillation, extraction and chromatography are emphasized as separation and purification techniques. Melting points, boiling points, and refractive indices are used routinely as measures of purity. Safe handling of chemicals and proper disposal of waste products are priority goals in this course. To help in attaining such goals, the first week of the semester is devoted to SAFETY in the chemistry laboratory. For the remainder of the semester, most of the experiments are conducted on a micro scale. BOOKS: 1. 100 pg. set Organic Chemistry Laboratory Notebook 2. “Organic Chemistry Laboratory Laboratory Techniques, 2nd ed”. Available as free pdf download at https://open.umn.edu/opentextbooks/BookDetail.aspx?bookId=369 3. “Microscale Techniques for the Organic Laboratory, 2nd ed”, (MTOL), Mayo, Pike, Butcher and Trumper, John Wiley & Sons, Inc.,2001 (on reserve at library circulation desk-currently out of print but available on Amazon) 4. “Right to Know pocket guide for School & University Employees”, Genium Publishing Corp., 1990. (optional) (#1 can be purchased from the book store) LAB SYLLABUS: Originally prepared by Prof. S. B. Hanna, modified by D. E. Hoiness, T.Bone. GENERAL GUIDELINES SAFETY Goggles must be worn at all times in the lab.
    [Show full text]
  • Microbiological Control 2 Intro | Table of Contents Content
    Microbiological Control 2 Intro | Table of Contents Content Table of Contents Microbiological Enumeration 6 Membrane Filters 28 Filtration Equipment Sterility Testing 60 Sterisart® Universal Pump 61 Sterisart® NF – Sterility Test Disposables 65 Reusable Sterility Test System Mycoplasma Contamination Control 70 Microsart® AMP Mycoplasma Air Monitoring 74 MD8 airscan® 75 AirPort MD8 76 Gelatine Membrane Filters 77 BACTair™ – Big Impact 78 Accessories Chemical Compatibility 84 Filter Materials & Mini Cartridges 86 Filter Holder | Cartridge Housing | O-ring Materials 88 Ready-to-Connect Filtration Units 90 Index Intro AirMicrobiological Monitoring Enumeration 5 Microbiological Enumeration Table of Contents 6 Membrane Filters 28 Filtration Equipment 6 Microbiological Enumeration Membrane Filters Membrane Filters 7 Gridded Cellulose Nitrate Membrane Filters (Cellulose Mixed Ester) acc. to ISO Standards 8 Cellulose Nitrate (Cellulose Mixed Ester) Membrane Filters 12 Microsart® e.motion Membrane Filters 13 Microsart® e.motion Dispenser 14 Cellulose Nitrate and Cellulose Acetate Membrane Filters 16 Hydrophobic Edged Membrane Filters 18 Nutrient Pad Sets 22 Culture Media in Bottles and Tubes 24 Biosart® 100 Monitors 27 Biosart® 100 Nutrient Media Membrane Filters Microbiological Enumeration 7 Gridded Cellulose Nitrate Membrane Filters (Cellulose Mixed Ester) acc. to ISO Standards Sterile and Individually Packaged, the methods of the Central European for Colony Counting Brewery Commission, the MNO Sterile, individually packed filters have (Mineral|Table Water Guideline), the long become standard for routine microbi- National Canners Association, the testing ological quality control because of the procedures for packaging stuff, the user benefits they offer. U.S. Environmental Protection Agency, the United States Pharmacopoeia, the They are pre-sterilized and ready-to-use US Department of Agriculture, the VLB and save preparatory time.
    [Show full text]
  • Environmental Chemistry Method Methoxyfenozide & Degradates In
    Dow AgroSciences LLC Study ID: 110356 Page 12 Method Validation Study for the Detennination of Residues of Methoxyfenozide and its A-ring • Phenol Metabolite and B-ring Mono Acid Metabolite in Surface Water, Ground Water and Drinking Water by Liquid Chromatography with Tandem Mass Spectrometry INTRODUCTION J This method is applicable for the quantitative detennination of residues of methoxyfenozide and its A-ring phenol metabolite and B-ring mono acid metabolite in surface, ground and drinking water. The method was validated over the concentration range of 0.05-1.0 µg/L with a validated limit of quantitation of 0.05 µg/L. Common names, chemical names, and molecular formulas for the analytes are given in Table I. This study was conducted to fulfill data requirements outlined in the EPA Residue Chemistry Test Guidelines, OPPTS 850. 7100 (/). The validation will also comply with the requirements of EU Council Regulation (EC) No. 1107/2009 with particular regard to Section 3 of SANCO/3029/99 rev.4 and Section 3 of SANCO/825/00 rev.8.1 as well as PMRA Regulatory Directive Dir98-02 (2-4). The validation was conducted following Dow AgroSciences SOP ECL-24 with exceptions noted in the protocol or by protocol amendment. Method Principle Residues of methoxyfenozide, its A-ring phenol metabolite and its B-ring mono acid metabolite • are extracted from water samples by taking a l 0.0-mL aliquot and placing in an I I -dram (45-mL) glass vial equipped with a PTFE-lined cap or a 50-mL polypropylene centrifuge tube equipped with a cap.
    [Show full text]
  • ARC Laboratory Manual for Architectural Conservators
    A LABORATORY MANUAL FOR ARCHITECTURAL CONSERVATORS Jeanne Marie Teutonico ICCROM Rome 1988 CONTENTS Foreword v Preface vii General Principles: Laboratory Science 1. Sampling 3 2. Measurement and Error: Precision, Accuracy, Statistics 7 3. Measurement: Mass (Use of the Balance) 11 4. Measurement: Length (Use of the Vernier Caliper and Micrometer) 16 5. Measurement: Volume 21 6. Measurement: Solutions 26 7. Measurement: pH 30 Porous Building Materials 8. Water Absorption by Total Immersion 35 9. Water Drop Absorption 41 10. Penetration of Water: Capillary Action 43 11. Porosity of Granular Beds 45 12. Porosity in Solids: Indirect Measurement by Water Absorption 50 13. Porosity in Solids: Hydrostatic Weighing 52 14. Movement of Salts 56 15. Salt Crystallization 57 16. Qualitative Analysis of Water-soluble Salts and This publication was printed with a generous Carbonates 58 contribution from the government of 17. Semiquantititive Analysis of Water-soluble Salts 68 Finland. Earthen Building Materials 18A. Particle Size Analysis: Part I Sieving Procedure 73 ISBN 92-9077-083-X Via di San Michele 13 00153 Rome RM, Italy Printed in Italy III Earthen Building Materials (continued) FOREWORD 18B. Particle Size Analysis: Part II Sedimentation Procedure: Hydrometer Method 83 19. Plastic Limit of Soils 96 After his appointment as director of ICCROM in 1977, Sir Bernard FEILDEN proposed to emphasize the interdisciplinary 20. Liquid Limit of Soils 102 character of conservation by introducing scientists to field work and architects to laboratories. Consequently it was decided to introduce a series of laboratory exercises Stone. Brick and Mortars designed for the needs of architectural conservators and conservation architects in the program of the International 21.
    [Show full text]
  • EXPERIMENT 15 TF Notes
    EXPERIMENT 15 TF Notes 1. Have students log onto LoggerPro3 and start heating water as soon as they arrive 2. This reaction is easily contaminated so students must never insert the thermometer directly into the cuvette containing the reaction. Instead they should rather measure the temperature of the water and equate that to the temperature of the solution in the cuvette. 3. We will be using hot gloves in this experiment. 4. Make sure you are familiar with the calculations necessary to fill out the chart. All the necessary equations are given at the top fo the page. Note that the temperature must be converted from °C to K. EXPERIMENT 15 Thermodynamics of Complex-Ion Equilibria Introduction Thermodynamic data for a reaction system provides researchers with information that is important from both theoretical and practical points of view. There are several thermodynamic properties that chemists pay close attention to when designing or carrying out experiments such as thermodynamic stability, the change in free energy of a reaction, and temperature dependence. For example, if a chemist wants to create a new type of solar cell that combines a semiconductor material with a novel conductive oxide and wants to make sure that the two materials will not react with each other, thermodynamics provide the answer. By finding the free energy change associated with the reaction, s/he can determine how stable the layers are in contact with each other and to what temperature. In this experiment, you will learn how to determine those parameters from a controlled experiment by using spectrometry to find concentration data at various temperatures.
    [Show full text]
  • 22 Bull. Hist. Chem. 8 (1990)
    22 Bull. Hist. Chem. 8 (1990) 15 nntn Cn r fr l 4 0 tllOt f th r h npntd nrpt ltd n th brr f th trl St f nnlvn n thr prt nd ntn ntl 1 At 1791 1 frn 7 p 17 AS nntn t h 3 At 179 brr Cpn f hldlph 8Gztt f th Untd Stt Wdnd 3 l 1793 h ntr nnnnt rprdd n W Ml "njn h Cht"Ch 1953 37-77 h pn pr dtd 1 l 179 nd nd b Gr Whntn th frt ptnt d n th Untd Stt S M ntr h rt US tnt" Ar rt Invnt hn 199 6(2 1- 19 ttrfld ttr fnjn h Arn hl- phl St l rntn 1951 pp 7 9 20h drl Gztt 1793 (20 Sptbr Qtd n Ml rfrn 1 1 W Ml rfrn 1 pp 7-75 William D. Williams is Professor of Chemistry at Harding r brt tr University, Searcy, Al? 72143. He collects and studies early American chemistry texts. Wyndham D. Miles. 24 Walker their British cultural heritage. To do this, they turned to the Avenue, Gaithersburg, MD 20877, is winner of the 1971 schools (3). This might explain why the Virginia assembly Dexter Award and is currently in the process of completing the took time in May, 1780 - during a period when their highest second volume of his biographical dictionary. "American priority was the threat of British invasion following the fall of Chemists and Chemical Engineers". Charleston - to charter the establishment of Transylvania Seminary, which would serve as a spearhead of learning in the wilderness (1).
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]