Outside Cable Filled Core. Moisture Barrier.

Description

Soft copper insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield and external jacket in polyethylene type moisture barrier. Construction

Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs) Spare pairs One spare pair white-red colored at the interstices of each 100 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Non-hygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Jacket Black polyethylene, abrasion, weather, and penetration to water resistant

7 Moisture Barrier Filled Core with elastomeric compound, aluminum tape both sides covered with copolymer and polyethylene external jacket, firmly bonded to external side of aluminum tape Options Manufacturing according to REA and/or Bellcore specifications Shield in Flat Aluminum tape. Armor in corrugated and copolymer covered Steel tape for direct buried and for rodent protection. Galvanized steel wires armor for vertical installations. Other Core Assemblies are available upon request. Applications Trunk cable and distribution cable networks. Special for wet locations; the elastomeric compound filler prevents the entrance of moisture to the core. Installation in ducts or raceways; for buried direct in locations without heavy traffic. CENTELSA Outside Telephone Cable, are able for voice and data transmission up to 6.3 MHz, optimizing the of copper cables.

Standards and Specifications

CENTELSA Outside Telephone Cable, are manufactured under the following standards: ANSI/ICEA S-84-608 cable filled, polyolefin insulated . ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Norma NTC 2061.

Note: Other configurations, sizes, colors and length not specified herein are available upon request.

8 Outside Telephone Cable. Filled Core. Moisture Barrier. Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL LENGTH (mm) (mm) (mm) (mm) WEIGTH BY REEL (kg/km) (m)

10 - 0.40 0.18 1.40 9.75 94 1500 20 - 0.40 0.18 1.40 11.56 141 1500 30 - 0.40 0.18 1.40 12.96 187 1500 40 - 0.40 0.18 1.40 14.13 231 1500 50 - 0.40 0.18 1.40 15.17 275 1500 70 - 0.40 0.18 1.40 16.96 356 1500 100 1 0.40 0.18 1.40 19.30 479 1000 150 2 0.40 0.18 1.60 22.87 692 1000 200 2 0.40 0.18 1.60 25.48 886 1000 300 3 0.40 0.18 1.60 29.91 1270 750 400 4 0.40 0.18 1.80 34.06 1668 500 500 5 0.40 0.18 1.80 37.35 2044 500 600 6 0.40 0.18 1.80 40.32 2419 500 900 9 0.40 0.18 2.00 48.48 3565 350 1200 12 0.40 0.18 2.20 55.32 4699 300 1500 15 0.40 0.18 2.40 61.43 5837 250 1800 18 0.40 0.18 2.40 66.73 6941 250 2400 24 0.40 0.18 2.40 75.88 9126 250 10 - 0.50 0.20 1.40 10.67 120 1500 20 - 0.50 0.20 1.40 12.86 188 1500 30 - 0.50 0.20 1.40 14.55 252 1500 40 - 0.50 0.20 1.40 15.97 316 1500 50 - 0.50 0.20 1.40 17.23 378 1500 70 - 0.50 0.20 1.40 19.40 498 1500 100 1 0.50 0.20 1.40 22.22 682 1000 150 2 0.50 0.20 1.60 26.46 996 1000 200 2 0.50 0.20 1.60 29.62 1283 1000 300 3 0.50 0.20 1.80 35.40 1876 750 400 4 0.50 0.20 1.80 39.92 2446 500 500 5 0.50 0.20 2.00 44.39 3037 500 600 6 0.50 0.20 2.00 47.99 3606 500 900 9 0.50 0.20 2.20 57.64 5312 350 1200 12 0.50 0.20 2.40 66.03 7018 300 1500 15 0.50 0.20 2.40 72.92 8684 250 1800 18 0.50 0.20 2.60 79.57 10386 250 2400 24 0.50 0.20 2.60 90.63 13682 250 10 - 0.60 0.26 1.40 12.08 158 1500 20 - 0.60 0.26 1.40 14.86 257 1500 30 - 0.60 0.26 1.40 17.00 350 1500 40 - 0.60 0.26 1.40 18.80 442 1500 50 - 0.60 0.26 1.40 20.38 531 1500 70 - 0.60 0.26 1.60 23.55 724 1500 100 1 0.60 0.26 1.60 27.13 994 1000 150 2 0.60 0.26 1.80 32.38 1452 1000 200 2 0.60 0.26 1.80 36.39 1880 1000 300 3 0.60 0.26 1.80 43.25 2732 750 400 4 0.60 0.26 2.00 49.38 3605 500 500 5 0.60 0.26 2.20 54.80 4475 500 600 6 0.60 0.26 2.20 59.35 5309 500 900 9 0.60 0.26 2.40 71.67 7848 350 1200 12 0.60 0.26 2.60 81.99 10374 300 1500 15 0.60 0.26 2.60 90.72 12846 250 1800 18 0.60 0.26 2.80 99.02 15371 250 2400 24 0.60 0.26 2.80 113.03 20280 250

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances. 9 Outside Telephone Cable. Filled Core. Moisture Barrier. Solid polyethylene insulation.

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL LENGTH (mm) (mm) (mm) (mm) WEIGTH BY REEL (kg/km) (m) 10 - 0.40 0.23 1.40 10.34 106 1500 20 - 0.40 0.23 1.40 12.40 160 1500 30 - 0.40 0.23 1.40 13.98 211 1500 40 - 0.40 0.23 1.40 15.32 262 1500 50 - 0.40 0.23 1.40 16.49 311 1500 70 - 0.40 0.23 1.40 18.53 405 1500 100 1 0.40 0.23 1.40 21.18 548 1000 150 2 0.40 0.23 1.60 25.18 792 1000 200 2 0.40 0.23 1.60 28.15 1015 1000 300 3 0.40 0.23 1.80 33.59 1476 750 400 4 0.40 0.23 1.80 37.83 1913 500 500 5 0.40 0.23 2.00 42.05 2377 500 600 6 0.40 0.23 2.00 45.43 2812 500 900 9 0.40 0.23 2.20 54.51 4128 350 1200 12 0.40 0.23 2.40 62.26 5440 300 1500 15 0.40 0.23 2.40 68.88 6714 250 1800 18 0.40 0.23 2.60 75.13 8026 250 2400 24 0.40 0.23 2.60 85.52 10547 250 10 - 0.50 0.30 1.40 11.83 142 1500 20 - 0.50 0.30 1.40 14.51 224 1500 30 - 0.50 0.30 1.40 16.57 306 1500 40 - 0.50 0.30 1.40 18.30 384 1500 50 - 0.50 0.30 1.40 19.83 459 1500 70 - 0.50 0.30 1.60 22.90 620 1500 100 1 0.50 0.30 1.60 26.34 850 1000 150 2 0.50 0.30 1.80 31.42 1232 1000 200 2 0.50 0.30 1.80 35.27 1590 1000 300 3 0.50 0.30 1.80 41.88 2300 750 400 4 0.50 0.30 2.00 47.81 3033 500 500 5 0.50 0.30 2.20 53.04 3762 500 600 6 0.50 0.30 2.20 57.42 4454 500 900 9 0.50 0.30 2.40 69.31 6561 350 1200 12 0.50 0.30 2.60 79.26 8663 300 1500 15 0.50 0.30 2.60 87.67 10713 250 1800 18 0.50 0.30 2.80 95.68 12813 250 2400 24 0.50 0.30 2.80 109.18 16877 250 10 - 0.60 0.35 1.40 13.13 177 1500 20 - 0.60 0.35 1.40 16.35 294 1500 30 - 0.60 0.35 1.40 18.82 407 1500 40 - 0.60 0.35 1.40 20.90 514 1500 50 - 0.60 0.35 1.40 22.74 624 1500 70 - 0.60 0.35 1.60 26.33 849 1500 100 1 0.60 0.35 1.60 30.47 1168 1000 150 2 0.60 0.35 1.80 36.49 1710 1000 200 2 0.60 0.35 1.80 41.11 2215 1000 300 3 0.60 0.35 2.00 49.45 3262 750 400 4 0.60 0.35 2.20 56.44 4292 500 500 5 0.60 0.35 2.40 62.83 5324 500 600 6 0.60 0.35 2.40 68.10 6320 500 900 9 0.60 0.35 2.60 82.11 9325 350 1200 12 0.60 0.35 2.60 93.57 12270 300 1500 15 0.60 0.35 2.80 104.08 15260 250 1800 18 0.60 0.35 2.80 113.20 18183 250 2400 24 0.60 0.35 3.00 129.82 24082 250

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances. 10 Outside Telephone Cable Filled Core. Double Jacket. Moisture Barrier.

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid. Core conformed by groups of pairs or by unit of groups of pairs. Filled core Aluminum shield and double Jacket (inner and outer) in polyethylene type moisture barrier.

Construction

Conductor Soft copper wires

Insulation Foam skin or solid high density polyethylene.

Twisted Pairs Insulated conductors are twisted into pairs

Core Assembly Up to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs)

Spare pairs One spare pair white-red colored at the interstices of each 100 pairs unit, to guarantee nominal numbers of pairs.

Identification Pairs, groups and units that conform the core, are identified by color code (Attached)

Inner Jacket Black polyethylene, abrasion, weather, and penetration to water resistant

11 Core Wrap Non-hygroscopic dielectric tape. Offers dielectric strength between core and sheath

Shield Corrugated Aluminum tape both sides covered with copolymer

Outer Jacket Black polyethylene, abrasion, weather, and penetration to water resistant

Moisture Barrier Filled Core with elastomeric compound, inner polyethylene jacket, aluminum tape both sides covered with copolymer and outer polyethylene external jacket, firmly bonded to external side of aluminum tape.

Options

Manufacturing according to REA and/or Bellcore specifications Shield in Flat Aluminum tape. Armor in corrugated and copolymer covered Steel tape for direct buried and for rodent protection. Galvanized steel wires armor for vertical installations. Other Core Assemblies are available upon request.

Applications

Trunk cable and distribution cable networks. Special for wet locations; the elastomeric compound filler prevents the entrance of moisture to the core.

Trunk cable and distribution cable networks. Special for wet locations; the elastomeric compound filler prevents the entrance of moisture to the core.

The inner jacket offers additional blocking to the entrance of humidity to the core, increases the dielectric strength pair-shield and improves cable resistance to penetration of sharp objects.

CENTELSA Outside Telephone Cable, are able for voice and data transmission up to 6.3 MHz, optimizing the bandwidth of copper cables.

12 Standards and Specifications

CENTELSA Outside Telephone Cable, are manufactured under the following standards:

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Standard NTC 2061.

Note: Other configurations, sizes, colors and length not specified herein are available upon request.

13 Outside Telephone Cable. Filled Core. Moisture Barrier. Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. TOTAL STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL WEIGTH LENGTH (mm) (mm) (mm) (mm) WEIGTH (kg/km) BY REEL (kg/km) (m)

10 - 0.40 0.18 0.70 1.40 11.15 116 1500 20 - 0.40 0.18 0.70 1.40 12.96 166 1500 30 - 0.40 0.18 0.70 1.40 14.36 215 1500 40 - 0.40 0.18 0.70 1.40 15.53 261 1500 50 - 0.40 0.18 0.70 1.40 16.57 307 1500 70 - 0.40 0.18 0.70 1.40 18.36 392 1500 100 1 0.40 0.18 0.70 1.40 20.70 519 1000 150 2 0.40 0.18 0.80 1.60 24.47 746 1000 200 2 0.40 0.18 0.80 1.60 27.08 947 1000 300 3 0.40 0.18 0.80 1.60 31.51 1341 750 400 4 0.40 0.18 0.90 1.80 35.86 1759 500 500 5 0.40 0.18 0.90 1.80 39.15 2144 500 600 6 0.40 0.18 0.90 1.80 42.12 2526 500 900 9 0.40 0.18 1.00 2.00 50.48 3712 350 1200 12 0.40 0.18 1.10 2.20 57.52 4882 300 1500 15 0.40 0.18 1.20 2.40 63.83 6057 250 1800 18 0.40 0.18 1.20 2.40 69.13 7173 250 2400 24 0.40 0.18 1.20 2.40 78.28 9390 250 10 - 0.50 0.20 0.70 1.40 12.07 143 1500 20 - 0.50 0.20 0.70 1.40 14.26 216 1500 30 - 0.50 0.20 0.70 1.40 15.95 283 1500 40 - 0.50 0.20 0.70 1.40 17.37 350 1500 50 - 0.50 0.20 0.70 1.40 18.63 415 1500 70 - 0.50 0.20 0.70 1.40 20.80 539 1500 100 1 0.50 0.20 0.70 1.40 23.62 729 1000 150 2 0.50 0.20 0.80 1.60 28.06 1059 1000 200 2 0.50 0.20 0.80 1.60 31.22 1354 1000 300 3 0.50 0.20 0.90 1.80 37.20 1971 750 400 4 0.50 0.20 0.90 1.80 41.72 2552 500 500 5 0.50 0.20 1.00 2.00 46.39 3178 500 600 6 0.50 0.20 1.00 2.00 49.99 3751 500 900 9 0.50 0.20 1.10 2.20 59.84 5502 350 1200 12 0.50 0.20 1.20 2.40 68.43 7254 300 1500 15 0.50 0.20 1.20 2.40 75.32 8938 250 1800 18 0.50 0.20 1.30 2.60 82.17 10686 250 2400 24 0.50 0.20 1.30 2.60 93.23 14031 250 10 - 0.60 0.26 0.70 1.40 13.48 183 1500 20 - 0.60 0.26 0.70 1.40 16.26 285 1500 30 - 0.60 0.26 0.70 1.40 18.40 386 1500 40 - 0.60 0.26 0.70 1.40 20.20 481 1500 50 - 0.60 0.26 0.70 1.40 21.78 574 1500 70 - 0.60 0.26 0.80 1.60 25.15 780 1500 100 1 0.60 0.26 0.80 1.60 28.73 1059 1000 150 2 0.60 0.26 0.90 1.80 34.18 1539 1000 200 2 0.60 0.26 0.90 1.80 38.19 1977 1000 300 3 0.60 0.26 0.90 1.80 45.05 2850 750 400 4 0.60 0.26 1.00 2.00 51.38 3754 500 500 5 0.60 0.26 1.10 2.20 57.00 4656 500 600 6 0.60 0.26 1.10 2.20 61.55 5504 500 900 9 0.60 0.26 1.20 2.40 74.07 8104 350 1200 12 0.60 0.26 1.30 2.60 84.59 10690 300 1500 15 0.60 0.26 1.30 2.60 93.32 13196 250 1800 18 0.60 0.26 1.40 2.80 101.82 15775 250 2400 24 0.60 0.26 1.40 2.80 115.83 20748 250

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances. 14 Outside Telephone Cable Air Core. Moisture Barrier.

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid. Air core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield and external jacket in polyethylene type moisture barrier.

Construction

Conductor Soft copper wires

Insulation Foam skin or solid high density polyethylene.

Twisted Pairs Insulated conductors are twisted into pairs

Core Assembly Up to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs)

Spare pairs One spare pair white-red colored at the interstices of each 100 pairs unit, to guarantee nominal numbers of pairs.

Identification Pairs, groups and units that conform the core, are identified by color code (Attached)

Core Wrap Non-hygroscopic dielectric tape. Offers dielectric strength between core and sheath

Shield Corrugated Aluminum tape both sides covered with copolymer

Jacket Black polyethylene, abrasion, weather, and penetration to water resistant

15 Moisture Barrier Filled Core with elastomeric compound, aluminum tape both sides covered with copolymer and polyethylene external jacket, firmly bonded to external side of aluminum tape

Options

Manufacturing according to REA and/or Bellcore specifications Shield in Flat Aluminum tape. Armor in corrugated and copolymer covered Steel tape for direct buried and for rodent protection. Galvanized steel wires armor for vertical installations. Other Core Assemblies are available upon request.

Applications

Trunk cable and distribution cable networks. For use in pressurized networks. Installation in ducts or raceways

CENTELSA Outside Telephone Cable, are able for voice and data transmission up to 6.3 MHz, optimizing the bandwidth of copper cables.

Standards and Specifications CENTELSA Outside Telephone Cable, are manufactured under the following standards:

ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Standard NTC 2061.

Note: Other configurations, sizes, colors and length not specified herein are available upon request.

16 Outside Telephone Cable. Air Core. Moisture Barrier. Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL LENGTH (mm) (mm) (mm) (mm) WEIGTH BY REEL (kg/km) (m) 10 - 0.40 0.15 1.40 9.41 86 1500 20 - 0.40 0.15 1.40 11.09 125 1500 30 - 0.40 0.15 1.40 12.38 163 1500 40 - 0.40 0.15 1.40 13.46 200 1500 50 - 0.40 0.15 1.40 14.42 232 1500 70 - 0.40 0.15 1.40 16.08 300 1500 100 1 0.40 0.15 1.40 18.24 404 1000 150 2 0.40 0.15 1.60 21.57 579 1000 200 2 0.40 0.15 1.60 23.98 734 1000 300 3 0.40 0.15 1.60 28.08 1047 750 400 4 0.40 0.15 1.60 31.53 1353 500 500 5 0.40 0.15 1.80 34.98 1678 500 600 6 0.40 0.15 1.80 37.73 1977 500 900 9 0.40 0.15 2.00 45.31 2908 350 1200 12 0.40 0.15 2.00 51.28 3800 300 1500 15 0.40 0.15 2.20 56.92 4716 250 1800 18 0.40 0.15 2.20 61.68 5595 250 2400 24 0.40 0.15 2.60 71.10 7438 250 10 - 0.50 0.17 1.40 10.26 108 1500 20 - 0.50 0.17 1.40 12.28 164 1500 30 - 0.50 0.17 1.40 13.84 217 1500 40 - 0.50 0.17 1.40 15.15 270 1500 50 - 0.50 0.17 1.40 16.30 318 1500 70 - 0.50 0.17 1.40 18.31 419 1500 100 1 0.50 0.17 1.40 20.91 566 1000 150 2 0.50 0.17 1.60 24.86 823 1000 200 2 0.50 0.17 1.60 27.77 1054 1000 300 3 0.50 0.17 1.80 33.13 1541 750 400 4 0.50 0.17 1.80 37.30 1998 500 500 5 0.50 0.17 2.00 41.39 2478 500 600 6 0.50 0.17 2.00 44.78 2941 500 900 9 0.50 0.17 2.20 53.71 4323 350 1200 12 0.50 0.17 2.20 60.93 5662 300 1500 15 0.50 0.17 2.40 67.85 7040 250 1800 18 0.50 0.17 2.40 73.60 8372 250 2400 24 0.50 0.17 2.60 84.22 11070 250 10 - 0.60 0.21 1.40 11.47 133 1500 20 - 0.60 0.21 1.40 14.00 214 1500 30 - 0.60 0.21 1.40 15.94 288 1500 40 - 0.60 0.21 1.40 17.58 361 1500 50 - 0.60 0.21 1.40 19.02 433 1500 70 - 0.60 0.21 1.60 21.94 587 1500 100 1 0.60 0.21 1.60 25.19 801 1000 150 2 0.60 0.21 1.60 29.59 1147 1000 200 2 0.60 0.21 1.60 33.23 1478 1000 300 3 0.60 0.21 1.80 39.82 2165 750 400 4 0.60 0.21 1.80 45.09 2829 500 500 5 0.60 0.21 2.00 50.09 3515 500 600 6 0.60 0.21 2.00 54.23 4164 500 900 9 0.60 0.21 2.20 65.44 6139 350 1200 12 0.60 0.21 2.40 74.86 8113 300 1500 15 0.60 0.21 2.60 83.21 10087 250 1800 18 0.60 0.21 2.60 90.39 12004 250 2400 24 0.60 0.21 2.80 103.54 15884 250

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

17 Outside Telephone Cable. Air Core. Moisture Barrier. Solid polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL LENGTH (mm) (mm) (mm) (mm) WEIGTH BY REEL (kg/km) (m) 10 - 0.40 0.15 1.40 11.15 107 1500 20 - 0.40 0.15 1.40 13.55 160 1500 30 - 0.40 0.15 1.40 15.39 208 1500 40 - 0.40 0.15 1.40 16.94 254 1500 50 - 0.40 0.15 1.40 18.30 298 1500 70 - 0.40 0.15 1.40 20.67 385 1500 100 1 0.40 0.15 1.40 23.75 515 1000 150 2 0.40 0.15 1.60 28.34 738 1000 200 2 0.40 0.15 1.60 31.79 938 1000 300 3 0.40 0.15 1.60 37.63 1334 750 400 4 0.40 0.15 1.80 43.05 1752 500 500 5 0.40 0.15 1.80 47.39 2138 500 600 6 0.40 0.15 1.80 51.32 2520 500 900 9 0.40 0.15 2.00 62.01 3694 350 1200 12 0.40 0.15 2.20 70.92 4858 300 1500 15 0.40 0.15 2.40 78.85 6024 250 1800 18 0.40 0.15 2.40 85.65 7142 250 2400 24 0.40 0.15 2.60 98.13 9417 250 10 - 0.50 0.19 1.40 12.66 137 1500 20 - 0.50 0.19 1.40 15.68 213 1500 30 - 0.50 0.19 1.40 17.99 284 1500 40 - 0.50 0.19 1.40 19.95 352 1500 50 - 0.50 0.19 1.40 21.67 418 1500 70 - 0.50 0.19 1.40 24.66 548 1500 100 1 0.50 0.19 1.40 28.54 742 1000 150 2 0.50 0.19 1.60 34.21 1075 1000 200 2 0.50 0.19 1.60 38.56 1378 1000 300 3 0.50 0.19 1.80 46.42 2009 750 400 4 0.50 0.19 1.80 52.63 2605 500 500 5 0.50 0.19 2.00 58.51 3228 500 600 6 0.50 0.19 2.00 63.61 3818 500 900 9 0.50 0.19 2.20 76.74 5602 350 1200 12 0.50 0.19 2.40 87.91 7383 300 1500 15 0.50 0.19 2.40 97.39 9106 250 1800 18 0.50 0.19 2.60 106.37 10882 250 2400 24 0.50 0.19 2.60 121.58 14297 250 10 - 0.60 0.22 1.40 14.21 172 1500 20 - 0.60 0.22 1.40 17.87 276 1500 30 - 0.60 0.22 1.40 20.68 374 1500 40 - 0.60 0.22 1.40 23.05 468 1500 50 - 0.60 0.22 1.40 25.14 560 1500 70 - 0.60 0.22 1.60 29.18 758 1500 100 1 0.60 0.22 1.60 33.89 1034 1000 150 2 0.60 0.22 1.80 40.68 1501 1000 200 2 0.60 0.22 1.80 46.02 1933 1000 300 3 0.60 0.22 1.80 54.96 2787 750 400 4 0.60 0.22 2.00 63.06 3670 500 500 5 0.60 0.22 2.20 70.07 4545 500 600 6 0.60 0.22 2.20 76.07 5380 500 900 9 0.60 0.22 2.40 91.95 7914 350 1200 12 0.60 0.22 2.60 105.41 10442 300 1500 15 0.60 0.22 2.60 116.91 12895 250 1800 18 0.60 0.22 2.80 127.71 15414 250 2400 24 0.60 0.22 2.80 146.16 20283 250

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

18 Outside Telephone Cable Self-supported Figure 8. Air Core. Moisture Barrier.

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid. Air core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield, support messenger and external jacket in polyethylene type moisture barrier. Construction

Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs) Spare pairs One spare pair white-red colored at the interstices of each 100 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Non-hygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Support Messenger 7 Strand high strength galvanized steel . Jacket Black polyethylene, abrasion, weather, and penetration to water resistant

19 Moisture Barrier Air Core (for pressurerd systems) with elastomeric compound, aluminum flat tape both sides covered with copolymer and polyethylene external jacket, firmly bonded to external side of aluminum tape Options

Manufacturing according to REA and/or Bellcore specifications Shield in corrugated Aluminum tape. Filled Core. Galvanized steel wires fully flooded for corrosion protection. Other Core Assemblies are available upon request. Applications

For pressured systems overhead trunk cable and distribution cable networks. Aerial installation suspended from Messenger CENTELSA Outside Telephone Cable, are able for voice and data transmission up to 6.3 MHz, optimizing the bandwidth of copper cables.

Standards and Specifications

CENTELSA Outside Telephone Cable Figure 8, are manufactured under the following standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by: ICONTEC (Colombia). Standard NTC 2061.

Note: Other configurations, sizes, colors and length not specified herein are available upon request.

20 Outside Telephone Cable. Figure 8. Air Core. Self Supported. Moisture Barrier. Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION EXTERNAL APPROX. STANDARD JACKET MESSENGER PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIMENSIONS TOTAL LENGTH (mm) (mm) (mm) (mm) STRANDS DIAMETER WEIGTH BY REEL No. (mm) (kg/km) (m) 10 - 0.40 0.15 1.40 8.03 x 18.67 7 1.57 221 1500 20 - 0.40 0.15 1.40 9.71 x 20.35 7 1.57 261 1500 30 - 0.40 0.15 1.40 11.00 x 21.64 7 1.57 298 1500 40 - 0.40 0.15 1.40 12.08 x 22.72 7 1.57 334 1500 50 - 0.40 0.15 1.40 13.04 x 23.68 7 1.57 368 1500 70 - 0.40 0.15 1.40 14.70 x 25.34 7 1.57 435 1500 100 1 0.40 0.15 1.40 16.86 x 27.50 7 1.57 536 1000 150 2 0.40 0.15 1.60 20.19 x 32.15 7 2.03 789 1000 200 2 0.40 0.15 1.60 22.61 x 34.57 7 2.03 946 1000 300 3 0.40 0.15 1.60 26.70 x 38.66 7 2.03 1256 750 10 - 0.50 0.17 1.40 8.88 x 19.52 7 1.57 242 1500 20 - 0.50 0.17 1.40 10.90 x 21.54 7 1.57 298 1500 30 - 0.50 0.17 1.40 12.46 x 23.10 7 1.57 352 1500 40 - 0.50 0.17 1.40 13.77 x 24.41 7 1.57 403 1500 50 - 0.50 0.17 1.40 14.93 x 25.57 7 1.57 453 1500 70 - 0.50 0.17 1.40 16.93 x 27.57 7 1.57 552 1500 100 1 0.50 0.17 1.40 19.54 x 31.50 7 2.03 780 1000 150 2 0.50 0.17 1.60 23.48 x 35.44 7 2.03 1033 1000 200 2 0.50 0.17 1.60 26.39 x 38.35 7 2.03 1266 1000 300 3 0.50 0.17 1.60 31.34 x 43.30 7 2.03 1728 750

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

21 Outside Telephone Cable. Figure 8. Air Core. Self Supported. Moisture Barrier. Solid polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor. NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled and dry.

NOMINAL SPARE CONDUCTOR INSULATION EXTERNAL APPROX. STANDARD JACKET MESSENGER PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIMENSIONS TOTAL LENGTH (mm) (mm) (mm) (mm) STRANDS DIAMETER WEIGTH BY REEL No. (mm) (kg/km) (m) 10 - 0.40 0.15 1.40 8.03 x 18.67 7 1.57 222 1500 20 - 0.40 0.15 1.40 9.71 x 20.35 7 1.57 263 1500 30 - 0.40 0.15 1.40 11.00 x 21.64 7 1.57 300 1500 40 - 0.40 0.15 1.40 12.08 x 22.72 7 1.57 336 1500 50 - 0.40 0.15 1.40 13.04 x 23.68 7 1.57 371 1500 70 - 0.40 0.15 1.40 14.70 x 25.34 7 1.57 439 1500 100 1 0.40 0.15 1.40 16.86 x 27.50 7 1.57 543 1000 150 2 0.40 0.15 1.60 20.19 x 32.15 7 2.03 799 1000 200 2 0.40 0.15 1.60 22.61 x 34.57 7 2.03 959 1000 300 3 0.40 0.15 1.60 26.70 x 38.66 7 2.03 1277 750 10 - 0.50 0.19 1.40 9.10 x 19.74 7 1.57 246 1500 20 - 0.50 0.19 1.40 11.22 x 21.86 7 1.57 305 1500 30 - 0.50 0.19 1.40 12.85 x 23.49 7 1.57 361 1500 40 - 0.50 0.19 1.40 14.22 x 24.86 7 1.57 414 1500 50 - 0.50 0.19 1.40 15.43 x 26.07 7 1.57 467 1500 70 - 0.50 0.19 1.40 17.52 x 28.16 7 1.57 570 1500 100 1 0.50 0.19 1.40 20.25 x 32.21 7 2.03 805 1000 150 2 0.50 0.19 1.60 24.35 x 36.31 7 2.03 1071 1000 200 2 0.50 0.19 1.60 27.40 x 39.36 7 2.03 1315 1000 300 3 0.50 0.19 1.60 32.57 x 44.53 7 2.03 1800 750

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

22 Outside Telephone Wire DWP Drop Wire Paralell

Description

Drop Wire Paralleled. Hard copper conductors or steel copper covered, polyethylene or PVC insulated. Construction

Conductor Hard copper or steel copper covered (CCS) Insulation Single layer Polyethylene for DWP-PE and insulation – jacket integral for DWP- 2PE, weather resistant. Polyethylene Insulation and PVC jacket for DWP PE-PVC. Flame retardant PVC for DWP-PVC. Paralleled conductors with polarization ridge and conductor separator membrane. Application

Self supporting one pair parallel conductor Drop Wire intended for aerial service connection to the subscriber Standards

CENTELSA telephone wires DWP are manufactured under the following standards: NTC 1300 Service Drop telephone wire, inside installations and jumper. Certifications

CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC 1300. Package 100 or 200 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.

23 Outside Telephone Wire (International System Unit) Drop Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

STRAND CROSS INSULATIONMATERIALINSULATION SEPARATOR JACKET EXTERNAL APPROX. DC INSULATION ONE SIZE DIAMETER SECTION MATERIALAISLAMIENTOTHICKNESS (mm) THICKNESS DIMENSIONS TOTAL RESISTANCE RESISTANCE CONDUCTOR TYPE CONDUCTOR TENSILE STRENGTH No. x AWG (mm) (mm2) (mm) (mm) (mm) WEIGTH AT 20° C1 (Mohm-km) (Nominal) (kg/km) (ohm/km) (MPa) 2 x 18 Hard Copper 1.02 0.82 PVC 0.800.80 1.00 - 2.62 x6.25 29 22.2 249 460 DWP PVC 2 x 20 Hard Copper 0.81 0.52 PVC 0.800.80 1.00 - 2.41 x 5.83 22 35.2 288 473 Copper DWP PVC CCS 2 x 18 1.02 0.82 PVC 0.800.80 1.00 - 2.62 x 6.25 28 72.6 249 875 Clad Steel Copper 0.80 DWP PE CCS 2 x 18 1.02 0.82 PE 0.80 1.00 - 2.62 x 6.25 23 72.6 6229 875 Clad Steel 0.80 2 x 18 Hard Copper 1.02 0.82 PE 0.80 1.00 - 2.62 x 6.25 24 22.2 6229 460 DWP PE 1.50 2 x 20 Hard Copper 0.81 0.52 PE 0.80 1.00 - 2.41 x 5.83 18 35.2 7202 473 DWP 2PE 2 x 18 Hard Copper 1.02 0.82 PE 1.60 - - 4.22 x 7.17 36 22.2 7167 460 2 x 18 Hard Copper 1.02 0.82 PE 0.70 - 0.80 4.02 x 8.05 49 22.2 362 460 DWP PE-PVC 2 x 20 Hard Copper 0.81 0.52 PE 0.70 - 0.80 3.81 x 7.63 40 35.2 409 473

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Hard cooper and 33.91 ohm-cmil/ft for steel copper covered. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Outside Telephone Wire (International System Unit) Drop Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

STRAND CROSS INSULATION INSULATION SEPARATOR JACKET EXTERNAL APPROX. DC INSULATION ONE SIZE DIAMETER SECTION MATERIAL THICKNESS (mils) THICKNESS DIMENSIONS TOTAL RESISTANCE RESISTANCE CONDUCTOR TYPE CONDUCTOR No. x AWG (mils) (kcmil) (mils) (mils) (mils) WEIGTH AT 20° C1 (Mohm/kft) TENSILE STRENGTH (Nominal) (pound/kft) (ohm/kft) (ksi) 2 x 18 Hard Copper 40 1.63 PVC 31 39 - 103 x 246 20 6.77 817 67 DWP PVC 2 x 20 Hard Copper 32 1.02 PVC 31 39 - 95 x 229 15 10.7 944 69 Copper DWP PVC CCS 2 x 18 40 1.63 PVC 31 39 - 103 x 246 19 22.1 817 127 Clad Steel Copper DWP PE CCS 2 x 18 40 1.63 PE 31 39 - 103 x 246 15 22.1 6229 875 Clad Steel 2 x 18 Hard Copper 40 1.63 PE 31 39 - 103 x 246 16 6.77 20437 67 DWP PE 2 x 20 Hard Copper 32 1.02 PE 31 39 - 95 x 229 12 10.7 23628 69 DWP 2PE 2 x 18 Hard Copper 40 1.63 PE 63 - - 166 x 282 25 6.77 23514 67 2 x 18 Hard Copper 40 1.63 PE 28 - 31 158 x 317 33 6.77 1188 67 DWP PE-PVC 2 x 20 Hard Copper 32 1.02 PE 28 - 31 150 x 300 27 10.7 1342 69

Notas: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Hard cooper and 58.62 ohm-mm2/km for steel copper covered. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

24 Outside Telephone Wire DWT Drop Wire Twisted

Description

Drop Wire Twisted. Hard copper conductor, individually insulated with polyethylene or PVC.

Construction

Conductor Hard copper

Insulation Black Polyethylene weather resistant or flame retardat PVC.

Application

Self supporting one pair twisted conductor Drop Wire intended for aerial service connection to the subscriber

Standards

CENTELSA telephone wires DWT are manufactured under the following standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

Certifications

CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC 1300.

Package 100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue are available upon request.

25 Outside Telephone Wire (International System Unit) Drop Wire Twisted

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

TYPE SIZE STRAND CROSS INSULATION DIAMETER EXTERNAL APPROX. DC INSULATION ONE CONDUCTOR No. x AWG DIAMETER SECTION THICKNESS OVER DIAMETER TOTAL RESISTANT RESISTANCE TENSILE STRENGTH (mm) (mm2) (mm) INSULATION (mm) WEIGTH AT 20°C1 (Mohm-km) (Nominal) (mm) (kg/km) (ohm/km) (MPa)

DWT PVC 2 x 18 1.02 0.82 0.80 2.62 5.25 28 22.7 249 460 DWT PVC 2 x 20 0.81 0.52 0.80 2.41 4.83 21 35.9 288 473 DWT PE 2 x 18 1.02 0.82 0.80 2.62 5.25 23 22.7 6229 460 DWT PE 2 x 20 0.81 0.52 0.80 2.41 4.83 17 35.9 7202 473

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Hard cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Outside Telephone Wire Drop Wire Twisted

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

TYPE SIZE STRAND CROSS INSULATION SEPARATOR EXTERNAL APPROX. DC INSULATION ONE CONDUCTOR No. x AWG DIAMETER SECTION THICKNESS (mils) DIAMETER TOTAL RESISTANT RESISTANCE TENSILE STRENGTH (mils) (kcmil) (mils) (mils) WEIGTH AT 20°C1 (Mohm-kft) (Nominal) (pound/kft) (ohm/kft) (ksi)

DWT PVC 2 x 18 40 1.63 31 103 207 19 6.90 817 67 DWT PVC 2 x 20 32 1.02 31 95 190 14 11.0 944 69 DWT PE 2 x 18 40 1.63 31 103 207 16 6.90 20437 67 DWT PE 2 x 20 32 1.02 31 95 190 11 11.0 23628 69

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Hard cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

26 Inside Telephone Cables

Description

Soft copper wires insulated with flame retardant PVC, paired, unshielded or shielded with aluminum foil and drain wire, external PVC jacket. Construction

Conductor Soft copper Insulation Flame retardant PVC Pairs Two insulated conductor twisted together Core Up to 25 pairs one group of pairs, for 30 pairs and more, groups of 10 or 25 pairs. Spare pairs One pair color coded White-Red for 10 pairs or more. Identification Pairs, groups an units in the assembly core, are identified by color code (included in this catalogue) Core Wrap Non hygroscopic polyester tape Shield Unshielded or shielded with aluminum foil and tinned copper drain wire Jacket Flame retardant PVC, gray colored. Characteristics

Mutual capacitance 120 nF/km. Capacitive Unbalance 400 pF (referred to 500 m).

27 DC Conductor Resistance 97.8 ohm/km. Maximum Operating Voltage 60 V. Insulation Resistance 500 Mohm-km. Dielectric Strength (60 seg) 1000 V AC, 1500 V DC.

Applications

For inside residential commercial and industrial applications. Appropriate for locations with electric interference produced by near power electric circuit. Installation in dry locations in ducts trays and race ways.

Standards

CENTELSA Inside Cables are manufactured under the following standards: NTC-983, IEC 189. Cables e hilos para bajas frecuencias con aislamiento y cubierta en PVC. Notes: 1. Optionally with tinned copper conductor 2. Other configurations and sizes not specified in this catalogue are available upon request.

28 Inside Unshielded Telephone Cable

Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL WEIGTH LENGTH (mm) (mm) (mm) (mm) (kg/km) BY REEL (m)

1 - 0.50 0.20 0.60 3.18 15 100 2 - 0.50 0.20 0.60 3.93 22 1000 3 - 0.50 0.20 0.60 4.50 28 1000 4 - 0.50 0.20 0.60 4.98 34 1000 5 - 0.50 0.20 0.60 5.40 40 1000 6 - 0.50 0.20 0.70 6.00 49 1000 10 1 0.50 0.20 0.70 7.26 79 2000 20 1 0.50 0.20 0.80 9.46 139 2000 25 1 0.50 0.20 0.80 10.32 168 2000 30 1 0.50 0.20 0.90 11.32 200 2000 40 1 0.50 0.20 0.90 12.72 255 1500 50 1 0.50 0.20 0.90 13.95 310 1000 70 1 0.50 0.20 1.00 16.31 424 1000 100 1 0.50 0.20 1.00 19.03 584 1000

Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Unshielded Telephone Cable

Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat.

NOMINAL SPARE CONDUCTOR INSULATION JACKET OVERALL APPROX. STANDARD PAIRS PAIRS DIAMETER THICKNESS THICKNESS DIAMETER TOTAL WEIGTH LENGTH (mm) (mm) (mm) (mm) (kg/km) BY REEL (m) 1 - 0.50 0.20 0.60 3.36 16 100 2 - 0.50 0.20 0.60 4.11 23 1000 3 - 0.50 0.20 0.60 4.68 30 1000 4 - 0.50 0.20 0.60 5.16 36 1000 5 - 0.50 0.20 0.60 5.58 42 1000 6 - 0.50 0.20 0.70 6.18 51 1000 10 1 0.50 0.20 0.70 7.44 81 2000 20 1 0.50 0.20 0.80 9.64 142 2000 25 1 0.50 0.20 0.80 10.50 171 2000 30 1 0.50 0.20 0.90 11.50 204 2000 40 1 0.50 0.20 0.90 12.90 259 1500 50 1 0.50 0.20 0.90 14.13 314 1000 70 1 0.50 0.20 1.00 16.49 429 1000 100 1 0.50 0.20 1.00 19.21 590 1000

Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances.

29 Inside Telephone Wire JWT Jumper Wire Twisted

Description

Twisted pair for cross connections, for inside use. Soft tinned copper insulated with PVC or PVC and Nylon, assembly in pairs, triads or quads.

Construction

Conductor Soft tinned copper wire

Insulation Flame retardant PVC for JWT. Flame retardant PVC insulation; abrasion oil and gasoline resistant Nylon jacket for JWT PVC-NY.

Applications

JWT: twisted telephone wire for inside use, cross connections, telephonic derivations and radio and TV equipment wiring.

JWT PVC-NY: connection wire in distributors, mini-distributors and telephonic equipment. Nylon jacket provides abrasion resistance.

JWT NY: connection wire in distributors, mini-distributors and telephonic equipment.

Radio and TV equipment wiring, weld able without remove the insulation, Diameter reduced tightness and low friction advantages given by Nylon insulation. Installation in dry locations, ducts or open installation.

Standards

CENTELSA telephone wires JWT are manufactured under the following standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

30 Certifications CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC 1300.

Package 100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue are available upon request.

Inside Telephone Wire JWT PVC (International System Units) Jumper Wire Twisted PVC

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION OVERALL EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS DIAMETER DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mm) (mm²) (mm) (mm) (mm) (kg/km) AT 20° C¹ (Mohm/km) (ohm/km) 2 x 22 0.64 0.32 0.30 1.24 2.49 8.4 57.4 174 3 x 22 0.64 0.32 0.30 1.24 2.68 12.6 57.4 174 4 x 22 0.64 0.32 0.30 1.24 3.00 16.8 57.4 174 2 x 24 0.51 0.21 0.25 1.01 2.02 5.4 91.0 180 3 x 24 0.51 0.21 0.25 1.01 2.18 8.1 91.0 180 4 x 24 0.51 0.21 0.25 1.01 2.44 10.9 91.0 180 2 x 0.6 0.60 0.28 0.30 1.20 2.40 7.6 66.0 183 3 x 0.6 0.60 0.28 0.30 1.20 2.59 11.3 66.0 183 4 x 0.6 0.60 0.28 0.30 1.20 2.90 15.1 66.0 183 2 x 0.5 0.50 0.20 0.25 1.00 2.00 5.2 95.0 183 3 x 0.5 0.50 0.20 0.25 1.00 2.16 7.9 95.0 183 4 x 0.5 0.50 0.20 0.25 1.00 2.41 10.5 95.0 183

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

31 Inside Telephone Wire JWT PVC Jumper Wire Twisted PVC

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION OVERALL EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS DIAMETER DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mils) (sq inches) (mils) (mils) (mils) (pound/kft) AT 20° C¹ (Mohm/kft) (ohm/kft)

2 x 22 25 0.64 11.8 48.9 97.9 5.7 17.5 572 3 x 22 25 0.64 11.8 48.9 105.5 8.5 17.5 572 4 x 22 25 0.64 11.8 48.9 118.1 11.3 17.5 572 2 x 24 20 0.40 9.8 39.8 79.6 3.6 27.7 592 3 x 24 20 0.40 9.8 39.8 85.8 5.5 27.7 592 4 x 24 20 0.40 9.8 39.8 96.1 7.3 27.7 592

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWT PVC-NY (International System Units) Jumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS NSULATION DIAMETER JACKET DIAMETER EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS OVER THICKNESS OVER JACKET DIAMETER TOTAL RESISTANCE RESISTANCE (mm) (mm2) (mm) INSULATION (mm) (mm) (mm) WEIGTH AT 20°C1 (Mohm-km) (mm) (kg/km) (ohm/km)

2 x 26 0.40 0.13 0.17 0.74 0.11 0.96 1.93 3.8 146 39 2 x 24 0.51 0.21 0.17 0.85 0.11 1.07 2.14 5.5 91.0 33 2 x 22 0.64 0.32 0.17 0.98 0.11 1.20 2.41 7.9 57.4 28 2 x 0.4 0.40 0.13 0.17 0.74 0.11 0.96 1.92 3.8 148 39 2 x 0.5 0.50 0.20 0.17 0.84 0.11 1.06 2.12 5.3 95.0 33 2 x 0.6 0.60 0.28 0.17 0.94 0.11 1.16 2.32 7.1 66.0 29

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWT PVC-NY Jumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS NSULATION DIAMETER JACKET DIAMETER EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS OVER THICKNESS OVER JACKET DIAMETER TOTAL RESISTANCE RESISTANCE (mils) (sq inches) (mils) INSULATION (mils) (mils) (mils) WEIGTH AT 20°C1 (Mohm-km) (mils) (kg/km) (ohm/km)

2 x 26 15.9 0.25 6.7 29.3 4.3 38.0 75.9 2.6 44.4 126 2 x 24 20.1 0.40 6.7 33.5 4.3 42.2 84.3 3.7 27.7 108 2 x 22 25.3 0.64 6.7 38.7 4.3 47.4 94.7 5.3 17.5 91

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Tinned cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

32 Inside Telephone Wire JWT NY (International System Units) Jumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION DIAMETER EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS OVER DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mm) (mm²) (mm) INSULATION (mm) (kg/km) AT 20° C¹ (Mohm/km) (mm) (ohm/km) 2 x 26 0.40 0.13 0.17 0.74 1.49 3.0 146 10 2 x 24 0.51 0.21 0.17 0.85 1.83 4.5 91.0 10 2 x 22 0.64 0.32 0.17 0.98 2.37 6.8 57.4 10 2 x 0.4 0.40 0.13 0.17 0.74 1.48 3.0 148 10 2 x 0.5 0.50 0.20 0.17 0.84 1.81 4.3 95.0 10 2 x 0.6 0.60 0.28 0.17 0.94 2.27 6.0 66.0 10

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWT NY Jumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION DIAMETER EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS OVER DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mils) (sq inches) (mils) INSULATION (mils) (pound/kft) AT 20° C¹ (Mohm/kft) (mils) (ohm/kft)

2 x 26 15.9 0.25 6.7 29.3 58.6 2.0 44.4 33 2 x 24 20.1 0.40 6.7 33.5 72.2 3.0 27.7 33 2 x 22 25.3 0.64 6.7 38.7 93.4 4.6 17.5 33

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Tinned cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

33 Inside Telephone Wire JWP Jumper Wire Parallel

Description

Inside drop wire paralleled. Soft copper insulated with PVC. Construction

Conductor Soft copper wire Insulation Flame retardant white PVC, paralleled conductors with polarization ridge.

Applications

Paralleled telephone wire for inside use from the interior box to exterior box; telephonic derivations. Installation in dry locations, ducts or open installation. Standards

CENTELSA telephone wires JWP are manufactured under the following standards: NTC 1300 Service Drop telephone wire, inside installations and jumper. Certifications

CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC 1300. Package 100 or 200 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.

34 Inside Telephone Wire JWP (International System Units) Jumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mm) (mm²) (mm) (mm) (kg/km) AT 20° C¹ (Mohm/km) (ohm/km) 2 x 20 0.81 0.52 0.60 2.01 x 4.03 18.1 33.9 240 2 x 22 0.64 0.32 0.60 1.84 x 3.69 13.5 54.2 279

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for Soft cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWP Jumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mm) (kcmil) (mils) (mils) (pound/kft) AT 20° C¹ (Mohm/kft) (ohm/kft) 2 x 20 32.0 1.02 23.6 79.3 x 158.5 12.2 10.3 787 2 x 22 25.3 0.64 23.6 72.6 x 145.1 9.1 16.5 914

Notes: 1. DC resistance calculated based on a 10.371 ohm-cmil/ft resistivity for Soft cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

35 Inside Telephone Wire JWP Jumper Wire Parallel

Description

Inside drop wire paralleled. Soft copper insulated with PVC. Construction

Conductor Soft copper wire Insulation Flame retardant white PVC, paralleled conductors with polarization ridge.

Applications

Paralleled telephone wire for inside use from the interior box to exterior box; telephonic derivations. Installation in dry locations, ducts or open installation. Standards

CENTELSA telephone wires JWP are manufactured under the following standards: NTC 1300 Service Drop telephone wire, inside installations and jumper. Certifications

CENTELSA Outside Telephone Wire, are certified by: CIDET (Colombia). Standard NTC 1300. Package 100 or 200 meters spools in corrugated carton boxes Note: other configurations and sizes not specified in this catalogue are available upon request.

34 Inside Telephone Wire JWP (International System Units) Jumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mm) (mm²) (mm) (mm) (kg/km) AT 20° C¹ (Mohm/km) (ohm/km) 2 x 20 0.81 0.52 0.60 2.01 x 4.03 18.1 33.9 240 2 x 22 0.64 0.32 0.60 1.84 x 3.69 13.5 54.2 279

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for Soft cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWP Jumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZE STRAND CROSS INSULATION EXTERNAL APPROX. DC INSULATION AWG or mm DIAMETER SECTION THICKNESS DIAMETER TOTAL WEIGTH RESISTANCE RESISTANCE (mm) (kcmil) (mils) (mils) (pound/kft) AT 20° C¹ (Mohm/kft) (ohm/kft) 2 x 20 32.0 1.02 23.6 79.3 x 158.5 12.2 10.3 787 2 x 22 25.3 0.64 23.6 72.6 x 145.1 9.1 16.5 914

Notes: 1. DC resistance calculated based on a 10.371 ohm-cmil/ft resistivity for Soft cooper. 2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

35 Electrical Characteristics Outside Telephone Cables

MUTUAL CAPACITANCE SIZE (mm) (nF/km) 0.4 0.5 0.6 Nominal1 52 52 52 Maximum average 55 55 55 Maximum individual 64 64 64

CAPACITIVE UNBALANCE INDIVIDUAL 95% (pF refered to 500m) VALUE OF VALUES Pair to pair (pF refered to 500m) 250 150 Pair to shield1 (pF/km) 2625 -

CROSSTALK Power Sum dB/305m ELFEXT ELNEXT Frequency Average Worst Pair Average Worst Pair kHz 0.4 mm 0.5 mm 0.6 mm 0.4, 0.5 and 0.6 mm 0.4, 0.5 and 0.6 mm 0.4, 0.5 and 0.6 mm 150 61 63 63 57 58 53 772 47 49 49 43 47 42 1600 41 42 43 37 43 38 3150 35 37 37 31 38 33 6300 29 31 31 25 34 29

Conductor DC Resistance SIZE (mm) (ohm/km) 0.4 0.5 0.6 Maximum average 144.0 92.1 63.9 Maximum individual 150.0 95.9 66.6

RESISTIVE UNBALANCE1 SIZE (mm) (%) 0.4 0.5 0.6 Maximum average 2.0 1.5 1.5 Maximum individual 5.0 5.0 4.0

DIELECTRIC STRENGTH SOLID FOAM SKIN (Volts) POLYETHYLENE POLYETHYLENE

Conductor A vs Conductor B 2000V, 3s 1000V, 3s 1000V, 60s 500V, 60s 6000V, 3s 2000V, 3s Conductor vs Shield 3000V, 60s 1000V, 60s

INSULATION RESISTANCE (Mohm-km) Filled Core Air Core 1500 5000

MAXIMUM AVERAGE SIZE (mm) ATENUATION1 (db/km) 0.4 0.5 0.6 A 1000 Hz 1.88 1.51 1.26 A 150 kHz 12.1 8.90 6.90 A 772 kHz 23.0 18.4 15.5

Notes: 1. Test or value not indicated in Standard NTC 2061. 2. Data herein indicated are subject to normal tolerances.

36 Pairs Codes in 25 Pairs Groups Inside¹ and Outside Telephone Cables

PAIRS CODES IN 25 PAIRS GROUPS

INSULATION COLOR PAIR No. CONDUCTOR A CONDUCTOR B 1 WHITE BLUE 2 WHITE ORANGE 10 PAIRS GROUP COLOR CODE 3 WHITE GREEN 4 WHITE BROWN INSULATION COLOR WHITE GREY PAIR No. 5 RED BLUE CONDUCTOR A CONDUCTOR B 6 7 RED ORANGE 1 WHITE BLUE 8 RED GREEN 2 WHITE ORANGE 9 RED BROWN 3 WHITE GREEN 10 RED GREY 4 WHITE BROWN 11 BLACK BLUE 5 WHITE GREY 12 BLACK ORANGE 6 RED BLUE 13 BLACK GREEN 7 RED NARANJA 14 BLACK BROWN 8 RED GREEN 15 BLACK GREY 9 RED BROWN 16 YELLOW BLUE 10 RED GREY 17 YELLOW ORANGE 18 YELLOW GREEN 19 YELLOW BROWN 20 YELLOW GREY 21 PURPLE BLUE 22 PURPLE ORANGE 23 PURPLE GREEN 24 PURPLE BROWN 25 PURPLE GREY

GROUP IDENTIFICATION

CONSTRUCTION GROUP No. PAIRS BINDER COLOR 1 1 to 10 WHITE - BLUE 2 11 to 20 WHITE - ORANGE 3 21 to 30 WHITE - GREEN 10 PAIR 4 31 to 40 WHITE - BROWN GROUPS 5 41 to 50 WHITE- GREY 6 51 to 60 RED - BLUE 7 61 to 70 RED - ORANGE 1 1 to 25 WHITE - BLUE 2 26 to 50 WHITE - ORANGE 3 51 to 75 WHITE - GREEN 4 76 to 100 WHITE - BROWN 5 101 to 125 WHITE- GREY 6 126 to 150 RED - BLUE 7 151 to 175 RED - ORANGE 25 PAIR 8 176 to 200 RED - GREEN GROUPS 9 201 to 225 RED - BROWN 10 226 to 250 RED - GREY 11 251 to 275 BLACK - BLUE 12 276 to 300 BLACK - ORANGE

Note: 1. Specifications for inside telephone cables up to 100 pairs.

37 Unit Color Code Identification Outside Telephone Cables

IDENTIFICATION FOR 4 GROUPS IN 100 PAIRS UNITS

CONSTRUCTION GROUP No. BINDER COLOR

1 WHITE - BLUE 2 WHITE - ORANGE 25 PAIRS 3 WHITE - GREEN 4 WHITE - BROWN

UNITS IDENTIFICATION

CONSTRUCTION UNIT No. PAIRS BINDER COLOR

1 1 to 100 WHITE - BLUE 2 101 to 200 WHITE - ORANGE 3 201 to 300 WHITE - GREEN 4 301 to 400 WHITE - BROWN 5 401 to 500 WHITE - GREY 6 501 to 600 RED - BLUE 7 601 to 700 RED - ORANGE 8 701 to 800 RED - GREEN 9 801 to 900 RED - BROWN 10 901 to 1000 RED - GREY 100 PAIRS UNIT 11 1001 to 1100 BLACK - BLUE (4 GROUPS 12 1101 to 1200 BLACK - ORANGE OF 25 PAIRS 13 1201 to 1300 BLACK - GREEN EACH) 14 1301 to 1400 BLACK - BROWN 15 1401 to 1500 BLACK - GREY 16 1501 to 1600 YELLOW - BLUE 17 1601 to 1700 YELLOW - ORANGE 18 1701 to 1800 YELLOW - GREEN 19 1801 to 1900 YELLOW - BROWN 20 1901 to 2000 YELLOW - GREY 21 2001 to 2100 PURPLE - BLUE 22 2101 to 2200 PURPLE - ORANGE 23 2201 to 2300 PURPLE - GREEN 24 2301 to 2400 PURPLE - BROWN

38 Unit Color Code Identification Outside Telephone Cables

CORE ASSEMBLY IN GROUPS OR UNITS

PAIRS ASSEMBLY PAIRS BY GROUP GROUPS BY UNIT

10 (0+1) GROUPS 10 - 20 (0+2) GROUPS 10 - 30 (0+3) GROUPS 10 - 40 (0+4) GROUPS 10 - 50 (0+5) GROUPS 10 - 70 (1+6) GROUPS 10 - 100 (0+4) GROUPS 25 - 150 (1+5) GROUPS 25 - 200 (2+6) GROUPS 25 - 300 (3+9) GROUPS 25 - 400 (0+4) UNITS 25 4 500 (0+5) UNITS 25 4 600 (1+5) UNITS 25 4 900 (2+7) UNITS 25 4 1200 (3+9) UNITS 25 4 1500 (1+5+9) UNITS 25 4 1800 (2+6+10) UNITS 25 4 2100 (2+8+11) UNITS 25 4 2400 (2+8+14) UNITS 25 4

39 Assembly and Identification for Multipair Telephone Cable Core Inside¹ and Outside Telephone Cables

10 PAIRS GROUP CABLES 25 PAIRS GROUP CABLES

20 to 70 pairs 100 to 300 pairs 20 Pairs Assembly (0+2) 100 Pairs Assembly (0+4)

White White Brown Blue White White Orange Blue White White Green Orange

30 Pairs Assembly (0+3) 150 Pairs Assembly (1+5) Red Blue White White White Green Blue White White Orange Grey Blue White White Green White Orange Brown

40 Pairs Assembly (0+4) 200 Pairs Assembly (2+6)

Red Green White White Red White Brown Blue Orange Green White White Orange Blue White White Red White Green Orange Blue Brown White Grey

50 Pairs Assembly (0+5) 300 Pairs Assembly (3+9)

White Black Black Blue Orange Grey White Red Blue Grey White White White White Brown Green Blue Brown Red White Brown White White Grey White Orange Red Orange Red Green Red Green Blue Orange

70 Pairs Assembly (1+6) Red Orange Red White Blue White Orange White Blue Blanco Grey Verde White Brown

Note:: 1.Specifications for telephone cables up to 100 pairs.

40 Assembly and Identification for Multipair Telephone Cable Core Inside¹ and Outside Telephone Cables

100 PAIRS UNIT CABLES (EACH UNIT 4 GROUPS OF 25 PAIRS) 400 to 2400 pairs 400 Pairs Assembly (0+4) 1500 Pairs Assembly (1+5+9) Black Brown Black Black Grey White White Red Green Blue Orange Blue White Red Orange Orng White White Black White White Green Brown Orng Grey Blue White Red White Green Green Black Brown Blue Red 500 Pairs Assembly (0+5) Red Brown Grey White Grey White 1800 Pairs Assembly (2+6+10) Blue Yellow Orange White Yellow Yellow Brown White Blue Red Green Green Orange White Black Red White Red Green Grey Orange Green Brown White White Orange Blue Black Red White Red 600 Pairs Assembly (1+5) Brown Blue Brown Grey White Red Black Grey Black Blue Green Blue White Black Orange Orange White White Grey Blue 2100 Pairs Assembly (2+8+11) Yellow White Yellow Grey White Green Brown Purple Red Red Brown Yellow Blue Brown Grey Green Red White Black 900 Pairs Assembly (2+7) Green Green Blue Yellow White White Orange Orange Blue Red Red White Black Red Brown Orange Brown Orange Green White Yellow Red White Green Blue Blue Grey Black Red White White Orange Blue Black Green Orange Black White Grey Brown Brown Red Blue White Grey 2400 Pairs Assembly (2+8+14) Purple Purple Orange Purple Blue Green 1200 Pairs Assembly (3+9) Yellow Red Red Purple Grey Brown Grey Brown Black Black Yellow Red White Black Blue Orange Green Green Rojo Brown Blue White White Gris White White White Orange Blue Brown Black Yellow Red White Red Green Blue Orange Green Orange Brown Brown White White Red White Orange Grey Yellow Orange Red Blue Grey Green Red Orange Green Red Blue Yellow Black Orange Blue Black Brown Grey

41