Cisco Cable Modem Termination System Feature Guide

Total Page:16

File Type:pdf, Size:1020Kb

Cisco Cable Modem Termination System Feature Guide Cisco Cable Modem Termination System Feature Guide September 2004 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 Text Part Number: 0L-1467-04 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California. NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. CCSP, the Cisco Square Bridge logo, Cisco Unity, Follow Me Browsing, FormShare, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, Registrar, ScriptShare, SlideCast, SMARTnet, StrataView Plus, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries. All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0406R) Cisco Cable Modem Termination System Feature Guide Copyright © 2001-2004, Cisco Systems, Inc. All rights reserved. CONTENTS Preface xv Purpose xv Audience xvi Document Organization xvi Conventions xviii Terms and Acronyms xix Related Documentation xix Cisco uBR Series Documentation xix Additional Documentation Resources xx Obtaining Documentation xx Cisco.com xx Documentation CD-ROM xxi Ordering Documentation xxi Documentation Feedback xxi Obtaining Technical Assistance xxi Cisco TAC Website xxii Opening a TAC Case xxii TAC Case Priority Definitions xxii Obtaining Additional Publications and Information xxiii Cable Interface Bundling for the Cisco CMTS 1 Contents 2 Prerequisites for Cable Bundling 2 Restrictions for Cable Bundling 2 Information About Cable Bundling 3 Benefits 4 Configuring Cable Bundling 4 Monitoring Cable Interface Bundling 7 Configuration Examples for Cable Interface Bundling 9 Basic Cable Interface Bundling Example 9 Additional References 10 Related Documents 10 Standards 11 MIBs 11 Cisco Cable Modem Termination System Feature Guide 0L-1467-04 iii Contents RFCs 12 Technical Assistance 12 Cable Monitor and Intercept Features for the Cisco CMTS 13 Contents 14 Prerequisites for Cable Monitor and Intercept 14 Restrictions for Cable Monitor and Intercept 14 Information About Cable Monitor and Intercept 14 Overview of the cable interface Command 15 Overview of the cable monitor Command 15 Benefits 17 How to Configure for Cable Intercept and Monitoring 17 Configuring the cable intercept Command 17 Configuring the cable monitor Command 19 Monitoring the Cable Intercept and Monitor Features 21 Displaying Information About Intercepted Traffic 21 Displaying Information About Monitored Traffic 21 DOCSIS Data Packets Example 22 Timestamped Packets Example 22 Configuration Examples 23 Cable Intercept Configuration Example 23 Cable Monitor Configuration Example (MAC Address) 23 Cable Monitor Configuration Example (Ethernet, MAC-Layer, and DOCSIS-Data Packets) 24 Additional References 24 Related Documents 24 Standards 25 MIBs 25 RFCs 25 Technical Assistance 26 DHCP, ToD, and TFTP Services for the Cisco CMTS 27 Contents 28 Prerequisites for DHCP, ToD, and TFTP Services 28 Restrictions for DHCP, ToD, and TFTP Services 28 Information About DHCP, ToD, and TFTP Services 29 Feature Overview 29 Internal DHCP Server 30 Cisco Cable Modem Termination System Feature Guide iv 0L-1467-04 Contents External DHCP Servers 32 Time-of-Day Server 33 TFTP Server 35 Benefits 36 How to Configure DHCP, ToD, and TFTP Services 37 Configuring DHCP Service 37 Configuring Time-of-Day Service 43 Configuring TFTP Service 45 Configuring A Basic All-in-One Configuration (optional) 48 Configuring an Advanced All-in-One Configuration (optional) 49 Optimizing the Use of an External DHCP Server 49 Configuration Examples 55 DHCP Server Examples 55 ToD Server Example 57 TFTP Server Example 57 Basic All-in-One Configuration Example 58 Advanced All-in-One Configuration Example 62 Additional References 68 Related Documents 68 Standards 70 MIBs 71 RFCs 71 Technical Assistance 71 Configuring DOCSIS 1.1 on the Cisco CMTS 73 Contents 74 Prerequisites for DOCSIS 1.1 Operations 74 Restrictions for DOCSIS 1.1 Operations 75 Information about DOCSIS 1.1 78 Feature Overview 78 DOCSIS 1.1 Quality of Service 80 Benefits 86 How to Configure the Cisco CMTS for DOCSIS 1.1 Operations 87 Configuring Baseline Privacy Interface (optional) 88 Downloading the DOCSIS Root Certificate to the CMTS (required) 91 Adding a Manufacturer’s Certificate as a Trusted Certificate (optional) 94 Adding a Manufacturer’s or CM Certificate to the Hotlist (required) 96 Cisco Cable Modem Termination System Feature Guide 0L-1467-04 v Contents Enabling Concatenation (optional) 99 Enabling DOCSIS Fragmentation (optional) 100 Monitoring DOCSIS Operations 101 Monitoring the DOCSIS Network 101 Monitoring the RF Network and Cable Interfaces 107 Monitoring BPI+ Operations 111 Command Summary 114 Configuration Examples for DOCSIS 1.1 Operations 115 DOCSIS 1.1 Configuration for Cisco uBR7246VXR Router (without BPI+) 115 DOCSIS 1.1 Configuration for Cisco uBR7246VXR Router (with BPI+) 117 DOCSIS 1.1 Configuration for Cisco uBR10012 Router (with BPI+) 121 Additional References 125 Related Documents 125 Standards 126 MIBs 127 RFCs 127 Technical Assistance 127 EtherChannel for the Cisco Cable Modem Termination System 129 Contents 130 Prerequisites for EtherChannel on the Cisco CMTS 130 Restrictions for EtherChannel on the Cisco CMTS 131 Information About EtherChannel on the Cisco CMTS 131 Introduction to EtherChannel on the Cisco CMTS 131 Cisco FastEtherChannel (FEC) and GigabitEtherChannel (GEC) on the Cisco uBR7246VXR Router 132 Cisco GigabitEtherChannel (GEC) on the Cisco uBR10012 Router 132 How to Configure EtherChannel on the Cisco CMTS 133 Configuring FEC or GEC EtherChannel on the Cisco CMTS 133 Verifying EtherChannel on the Cisco CMTS 136 Configuration Examples for EtherChannel on the Cisco CMTS 136 Additional References 140 Related Documents 140 Standards 142 MIBs 142 Technical Assistance 142 Command Reference for EtherChannel on the Cisco CMTS 143 Glossary 149 Cisco Cable Modem Termination System Feature Guide vi 0L-1467-04 Contents Flap List Troubleshooting for the Cisco CMTS 151 Contents 152 Prerequisites for Flap List Troubleshooting 152 Restrictions for Flap List Troubleshooting 152 Information About Flap List Troubleshooting 152 Feature Overview 153 Information in the Flap List 153 Cisco Cable Manager and Cisco Broadband Troubleshooter 154 Benefits 155 How to Configure Flap List Troubleshooting 155 Configuring Flap List Operation Using the CLI (optional) 155 Clearing the Flap List and Counters Using the CLI (optional) 157 Enabling or Disabling Power Adjustment Using the CLI (optional) 158 Configuring Flap List Operation Using SNMP (optional) 161 Clearing the Flap List and Counters Using SNMP (optional) 161 How to Monitor and Troubleshoot Using Flap Lists 162 Displaying the Flap List Using the show cable flap-list Command 162 Displaying the Flap List Using the show cable modem flap Command 166 Displaying the Flap List Using SNMP 166 Displaying Flap-List Information for Specific Cable Modems 167 Troubleshooting Suggestions 169 Configuration Examples for Flap List Troubleshooting 171 Additional References 172
Recommended publications
  • Application Description PROCONTROL P 87TS01-E/R1313 Coupling Module
    Application Description PROCONTROL P Communication Coupling Module Time Master Publication No. D KWL 6316 96 E, Edition 10/96 Replacing D KWL 6316 96 E, Edition 05/96 87TS01-E/R1313 Application Every 59th second, a DCF77 time receiver coupled to the 87TS01-E/ R1313 module through an RS232c interface, conĆ forming to the prescribed time data format and transfer protoĆ Within the PROCONTROL system, module 87TS01-E/R1313col, sends the complete time telegram of the following full minĆ functions as a master clock which is set by a radioute clock and, (over in the 60th second, sends a synchronization characĆ a serial interface; reception is from the DCF77 timeter. transmitĆ This synchronization character is evaluated, and the interĆ ter), and which needs to be synchronized. The timenal received clock in module 87TS01-E/R1313 is synchronized. from the radio clock is made available to the entire PROCONĆ TROL system and is used as system time. It isThe transmitted master clock follows a 5-msec-rhythm and is synchroĆ cyclically in the form of time telegrams. nized to the DCF77 time receiver every 60 sec. Disturbance signals are generated if the time receiver or the internal clock The time telegrams containing the system time mayshould be reĆ fail. If synchronization takes place every 60 sec, the ceived and processed by modules specifically designedmaster for clock tends to go slow by < 5 msec. In the event of a this purpose. failure of the time receiver, the typical inaccuracy of the internal master clock is 3.4 sec/24 hrs. If an inaccuracy of a maximum of ± 1 sec is detected, the master clock is immediately switched over to the time received from the DCF77 time receiver.
    [Show full text]
  • GPS170PEX User Manual
    Technical Information Operating Instructions GPS170PEX Contact Information Meinberg Funkuhren GmbH & Co. KG Lange Wand 9 D-31812 Bad Pyrmont Phone: ++49 52 81 - 9309-0 Fax: ++49 52 81 - 9309-30 Internet: http://www.meinberg.de Email: [email protected] September 16, 2009 Table of Contents Contact Information............................................................................. 2 Content of the USB stick ..................................................................... 5 General information............................................................................. 6 PCI Express (PCIe) .............................................................................. 7 Block diagram GPS170PEX ................................................................ 8 GPS170PEX features ........................................................................... 9 Time zone and daylight saving .................................................. 9 Asynchronous serial ports ........................................................ 10 Time capture inputs.................................................................. 10 Pulse and frequency outputs .................................................... 10 DCF77 emulation ..................................................................... 12 Connectors and LEDs in the rear slot cover ...................................... 13 Installing the GPS170PEX in your computer.................................... 14 Configuring the 9 pin connector .............................................. 14 Mounting the
    [Show full text]
  • 7502.9039-MANUAL-Montgomery-MIPROM-21.Pdf
    This is Your Software Security Access Key: DO NOT LOSE IT ! DO NOT PLUG THE SECURITY KEY INTO ANY ELEVATOR INTERFACE PORT This security device must be plugged into the notebook computer’s PRINTER port whenever the FREEDOM Tool Software is to be run. List of Trademarks Microsoft Windows, Windows 95, and MS-DOS are registered trademarks/products of Microsoft Corporation. Megatech and MIPROM 21 are trademarks of the Montgomery-Kone Elevator Corporation. IBM and PS/2 are registered trademarks of International Business Machines Corporation WORLD electronics, the WORLD electronics logo, FREEDOM Tool and FREEDOMWare are registered trademarks of WORLD electronics Sales and Service, Inc. All other trademarks mentioned in this manual are the sole property of their respective manufacturers. Copyright © 1998-2003 by WORLD electronics®. All rights reserved. Printed in the United States of America. Except as permitted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system, without the prior written permission of WORLD electronics. Further, this publication and features described herein are subject to change without notice from the publisher. WORLD electronics Table of Contents Introduction ................................................................................................ 2 Features ................................................................................................................................
    [Show full text]
  • Conversion from Decimal There Is a Simple Method That Allows Conversions from the Decimal to a Target Number System
    APPENDICES A Number Systems This appendix introduces background material on various number systems and representations. We start the appendix with a discussion of various number systems, including the binary and hexadecimal systems. When we use multiple number systems, we need to convert numbers from system to another We present details on how such number conversions are done. We then give details on integer representations. We cover both unsigned and signed integer representations. We close the appendix with a discussion of the floating-point numbers. Positional Number Systems The number systems that we discuss here are based on positional number systems. The decimal number system that we are already familiar with is an example of a positional number system. In contrast, the Roman numeral system is not a positional number system. Every positional number system has a radix or base, and an alphabet. The base is a positive number. For example, the decimal system is a base-10 system. The number of symbols in the alphabet is equal to the base of the number system. The alphabet of the decimal system is 0 through 9, a total of 10 symbols or digits. In this appendix, we discuss four number systems that are relevant in the context of computer systems and programming. These are the decimal (base-10), binary (base-2), octal (base-8), and hexadecimal (base-16) number systems. Our intention in including the familiar decimal system is to use it to explain some fundamental concepts of positional number systems. Computers internally use the binary system. The remaining two number systems—octal and hexadecimal—are used mainly for convenience to write a binary number even though they are number systems on their own.
    [Show full text]
  • Agent Builder Troubleshooting Guide Chapter 1
    IBM Agent Builder Version 6.3.1 Troubleshooting Guide IBM Agent Builder Version 6.3.1 Troubleshooting Guide ii Agent Builder Troubleshooting Guide Chapter 1. Gathering product information for IBM Software Support Gather certain product information before you contact IBM® Software Support. About this task Gather the product information that is detailed in: Table 1. Procedure Gather the following information before you contact IBM Software Support: Table 1. Information to gather before you contact IBM Software Support Information type Description Log files Collect trace log files from failing systems. Most logs are in a logs subdirectory on the host computer. See Chapter 2, “Agent Builder Trace logging,” on page 3 for lists of all trace log files and their locations. Operating system Operating system version number and patch level Messages Messages and other information that is displayed on the screen Version numbers for an IBM Tivoli® Monitoring environment Version number of the following members of the monitoring environment v Tivoli Monitoring. Also, provide the patch level, if available. v Tivoli Monitoring: Windows OS Agent v Tivoli Monitoring: UNIX OS Agent v Tivoli Monitoring: Linux OS Agent Version numbers for an IBM Performance Management Version number of the following members of the environment monitoring environment v Operating System agent installed on the monitored system. v Monitoring Infrastructure Node (if installed on your premises). Tip: If you are using IBM Performance Management (SaaS), you do not install the Monitoring Infrastructure Node on your premises. Instead, a version hosted in the cloud is used. In this case, you do not need to provide the version number for this component.
    [Show full text]
  • Digital Alarm Communicator/Transmitters 411/411UD Manual
    Digital Alarm Communicator/Transmitters 411/411UD Manual Document LS10105-000GE-E 1/29/2014 Rev: A P/N LS10105-000GE-E:A ECN 13-875 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! An automatic fire alarm system—typically made up of smoke (caused by escaping gas, improper storage of flammable materi- detectors, heat detectors, manual pull stations, audible warning als, etc.). devices, and a fire alarm control panel (FACP) with remote notifi- Heat detectors do not sense particles of combustion and alarm cation capability—can provide early warning of a developing fire. only when heat on their sensors increases at a predetermined Such a system, however, does not assure protection against rate or reaches a predetermined level. Rate-of-rise heat detec- property damage or loss of life resulting from a fire. tors may be subject to reduced sensitivity over time. For this An emergency communication system—typically made up of reason, the rate-of-rise feature of each detector should be tested an automatic fire alarm system (as described above) and a life at least once per year by a qualified fire protection specialist. safety communication system that may include an autonomous Heat detectors are designed to protect property, not life. control unit (ACU), local operating console (LOC), voice commu- IMPORTANT! Smoke detectors must be installed in the same nication, and other various interoperable communication meth- room as the control panel and in rooms used by the system for ods—can broadcast a mass notification message.
    [Show full text]
  • Embedded Systems Programming with the Microchip PIC16F877 Microcontroller
    EMBEDDED SYSTEMS PROGRAMMING WITH THE PIC16F877 Second Edition By Timothy D. Green Copyright 2008 by Timothy D. Green All Rights Reserved. Table of Contents Preface …………………………………………………………………. 5 List of Figures …………………………………………………………. 6 Abbreviations and Acronyms …………………………………………. 7 Trademarks ……………………………………………………………. 10 Chapter 1 Introduction to ESP and the PIC …………………………. 11 Chapter 2 Microcontrollers and the PIC16F877 ……………………. 15 Section 2.0 Chapter Summary ……………………………….. 15 Section 2.1 Memory and Memory Organization ……………. 15 Section 2.2 The PIC16F877 …………………………………. 16 Section 2.3 Programming the PIC …………………………… 17 Chapter 3 Simple PIC Hardware & Software (“Hello World”) …….. 20 Section 3.0 Chapter Summary ……………………………….. 20 Section 3.1 A Simple Example System ……………………… 20 Section 3.2 Summary of Instructions and Concepts …………. 25 Chapter 4 The PIC Instruction Set (Part I) ………………………….. 27 Section 4.0 Chapter Summary ………………………………. 27 Section 4.1 The PIC16F877 Instruction Set ………………… 27 Section 4.2 Summary of Instructions and Concepts …………. 33 Chapter 5 The PIC Instruction Set (Part II) …………………………. 34 Section 5.0 Chapter Summary ……………………………….. 34 Section 5.1 Introduction ……………………………………… 34 Section 5.2 Keypad and Display Interface …………………… 35 Section 5.3 The STATUS Register and Flag Bits ……………. 39 Section 5.4 The Keypad Software ……………………………. 40 Section 5.5 The LED Display Software ……………………… 43 Section 5.6 Improved Display and Indirect Addressing ……… 46 Section 5.7 Odds & Ends …………………………………….. 50 Section 5.8 Using KEY_SCAN and DISPLAY Together ……. 54 Section 5.9 A Last Look at the Advanced Security System ….. 56 Section 5.10 Summary of Instructions and Concepts ………… 57 Chapter 6 Fundamental ESP Techniques ……………………………. 59 Section 6.0 Chapter Summary ………………………………… 59 Section 6.1 Introduction ………………………………………. 59 Section 6.2 Software Readability …………………………… 59 Section 6.3 Software Maintainability ………………………….
    [Show full text]
  • Technical Description 6036
    Technical Description Radio Clock for IBM PC XT/AT and Compatible 6036 version 04.02 30.08.99 Radio Clock 6036 KRSIBElektronik KRSIBElektronik Nottebohmstr. 41 58511 Lüdenscheid post box 1847 58468 Lüdenscheid fon: 02351 / 938686 fax: 02351 / 459590 Internet: http://www.hopf-time.com e-mail: [email protected] version 04.02 page 2 Radio Clock 6036 KRSIBElektronik CONTENS Page 1 General Information about the Circuit Board 6036 5 2 Starting the Radio Clock Circuit Board 6036 5 2.1 Hardware Setting Base Address and Mode 5 2.1.1 Mode 6030 = Limited Address Range of Hex 10 Addresses 6 2.1.2 Mode 6035/6036 = Extended Address Range of Hex 40 Addresses 6 2.1.3 UTC-Offset 6 3 Organisation of the Internal Clock Data 7 3.1 Example Reading of Time Data 8 3.2 Data Format 8 3.3 Setting the Clock with a New Time (in mode 6035/6036 only) 9 3.4 Millisecond 9 4 Status of the Clock and Reception Quality 10 4.1 Radio Operation 11 4.2 Quartz Operation 11 4.3 Reception Quality and Control Accuracy 11 5 Interrupt Possibilities 12 5.1 Activation of the Interrupt Output (only in mode 6035/6036) 12 5.2 Secondsynchronous Interrupts 13 5.3 Stopping the Interrupt Output 13 6 Reset of the Clock (only in Mode 6035/6036) 13 7 Master / Slave Operation of the Clock (in mode 6035/6036 only) 14 8 Antenna Installation 15 8.1 Usable Types of Antennas 15 8.2 Alignment of the antenna 15 8.3 Indirect Lightning Protection 18 9 Programming Help, Precautionary Measures and Source of Errors 19 10 Pulse Output 19 11 Description of the Front Panel of the Board 20 12 Technical Data 21 version 04.02 page 3 Radio Clock 6036 KRSIBElektronik second page for table of contents version 04.02 page 4 Radio Clock 6036 KRSIBElektronik 1 General Information about the Circuit Board 6036 • latest receiver design with faultless decoding of the signal even in difficult reception situations • plugging jumpers not necessary! All address and mode settings are carried out by the software included in the delivery.
    [Show full text]
  • Cobox Network Time Server
    CoBox Network Time Server Installation Guide CONTENTS 1 DESCRIPTION OF THE NETWORK TIME SERVER (NTS) 2 RELIABLE CLOCK SOURCES GLOBAL POSITIONING SATELLITE (GPS) SYSTEM .................................. 2-1 DCF-77 LF RADIO TRANSMITTER......................................................... 2-1 WWVB RADIO TRANSMITTER .............................................................. 2-1 3 HARDWARE INSTALLATION REQUIREMENTS CONTROLLER........................................................................................ 3-1 ANTENNA............................................................................................. 3-1 ANTENNA CABLE.................................................................................. 3-1 4 CONTROLLER SETUP NETWORK CONFIGURATION .................................................................. 4-1 FACTORY IP ADDRESS .......................................................................... 4-1 INITIAL IP ADDRESS SETTING ............................................................... 4-1 SERIAL CONFIGURATION....................................................................... 4-2 CONFIGURATION PARAMETERS ............................................................. 4-3 BASIC PARAMETERS ............................................................................. 4-3 Ethernet Interface ......................................................................... 4-3 Token Ring Interface .................................................................... 4-3 Locally Administered Hardware Address .....................................
    [Show full text]
  • Acclima TDR Sensor User Manual
    Acclima TDR Sensor User Manual Contents About the TDR Sensor ................................................................................................................................... 2 TDR Sensor Models ....................................................................................................................................... 2 TDR315x Description and Installation ....................................................................................................... 3 TDR315x Optimum Application ................................................................................................................ 3 TDR310x Description and Installation ....................................................................................................... 3 TDR310x Optimum Application ................................................................................................................ 4 TDR305x Description, Installation and Optimum Application .................................................................. 4 Sensor Connection and Setup ....................................................................................................................... 4 Sensor Connections .................................................................................................................................. 4 Setting the Sensor Address ....................................................................................................................... 5 Setting Addresses using the Acclima SDI-12 Reader ............................................................................
    [Show full text]
  • EASY204-DP, PROFIBUS-DP Slave Interface
    Rückenbreite bis 10 mm (1 Blatt = 0,106 mm für XBS) EASY204-DP Moeller GmbH PROFIBUS-DP Industrieautomation Hein-Moeller-Straße 7–11 D-53115 Bonn Slave Interface E-Mail: [email protected] Internet: www.moeller.net © 2002 by Moeller GmbH Änderungen vorbehalten AWB2528-1401GB xx/xx/XBS 03/05 Printed in the Federal Republic of Germany (0x/02) Article No.: xxxxxx 4 *patpks#nycmyn* Operating manual Operating manual 03/05 AWB2528-1401GB A A Think future. Switch to green. Think future. Switch to green. A Rückenbreite festlegen! (1 Blatt = 0,106 mm) All brand and product names are trademarks or registered trademarks of the owner concerned. 1st published 2001, edition date 04/01 2nd edition 05/2003 3rd edition 07/2004 See revision protocol in the “About this manual“ chapter © Moeller GmbH, 53105 Bonn Authors: Ronny Happ, Dieter Bauerfeind Editor: Thomas Kracht Translator: Terence Osborn All rights reserved, including those of the translation. No part of this manual may be reproduced in any form (printed, photocopy, microfilm or any other process) or processed, duplicated or distributed by means of electronic systems without written permission of Moeller GmbH, Bonn. Warning! Dangerous electrical voltage! Before commencing the installation • Disconnect the power supply of the device. • Suitable safety hardware and software • Ensure that devices cannot be accidentally measures should be implemented for the restarted. I/O interface so that a line or wire breakage on the signal side does not result in • Verify isolation from the supply. undefined states in the automation • Earth and short circuit. devices. • Cover or enclose neighbouring units that • Ensure a reliable electrical isolation of the are live.
    [Show full text]
  • Overview of ASCII/RS-485 Time Protocol
    TN-108 Sep-2017 TECHNICAL NOTE Overview of ASCII/RS-485 Time Protocol Introduction Summary ASCII/RS-485 is based on a simple time protocol originally defined by Arbiter Some power meters use an ASCII character string Systems called “ASCII + QUAL.” An ASCII string is communicated over RS-485 and transmitted over RS-485 for time synchronization. consists of an on-time mark (OTM) transmitted once per second, followed by an ASCII representation of the date/time and time quality. This document describes the protocol, and gives ex- amples of how Cyber Sciences products are used to This protocol is used by some power meters for time synchronization via a spare synchronize devices require this protocol, including RS-485 data communications port. Devices which support ASCII/RS-485 include: TM PM8000 and ION7550/7650 meters by Schneider PowerLogic PM8000 and ION7550/7650 meters by Schneider Electric and 9410 and Electric and 9410 and 9510/9610 meters by Siemens. 9510/9610 meters by Siemens. CyTimeTM SER-3200/2408 Sequence of Events Recorders can generate ASCII/RS-485 to synchronize these power meters, greatly simplifying time sync design. PROTOCOL DESCRIPTION ASCII Time Code ASCII/RS-485 is the name for an ASCII-based time protocol distributed over a stan- dard RS-485 2-wire network. The ASCII code (called “ASCII + QUAL”) consists of an on-time mark (OTM) once per second followed by ASCII representation of the date/ time and time quality as follows: <soh>ddd:hh:mm:ssQ<cr><lf> where: <soh> = hex 01 (start of header = OTM) ddd:hh:mm:ss = date/time (day of the year, hour, min, sec) Q = time quality flag (space = locked, ? = unknown) <cr> = hex 0d (carriage return code) <lf> = hex 0a (line feed code) Note: As shown above, the ASCII code includes an ambiguity of one year, and so the device must first be set to the correct year through other means.
    [Show full text]