Florida Keys Aqueduct Authority Navy Systems Upgrades Wastewater Pumping Systems
Total Page:16
File Type:pdf, Size:1020Kb
FLORIDA KEYS AQUEDUCT AUTHORITY NAVY SYSTEMS UPGRADES WASTEWATER PUMPING SYSTEMS BOCA CHICA KEY SIGSBEE PARK FLEMING KEY BOARD OF DIRECTORS J. Robert Dean CHAIRMAN Richard J. Toppino PROJECT LOCATIONS VICE-CHAIRMAN David C. Ritz SECRETARY-TREASURER Antoinette M. Appell Cara Higgins Kirk C. Zuelch EXECUTIVE DIRECTOR CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA TITLE SHEET TITLE N.T.S. OPERATIONS GENERAL NOTES: INDEX OF DRAWINGS A. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES WITH FACILITIES IN PROXIMITY TO THE PROPOSED WORK 48 HOURS PRIOR TO STARTING WORK AND SHALL COORDINATE WORK SHEET G1 GENERAL NOTES & SHEET INDEX WITH UTILITY REPRESENTATIVES. SHEET A-647_1 A-647 SITE OVERVIEW B. THE CONTRACTOR SHALL NOTIFY THE FKAA CONTRACT OFFICE 48 HOURS PRIOR TO STARTING WORK SO THAT INSPECTION MAY BE PROVIDED. INSPECTIONS WILL BE MADE BETWEEN 8:00 A.M. AND 5:00 P.M. MONDAY THROUGH FRIDAY EXCLUDING LEGAL HOLIDAYS. WHEN INSPECTORS ARE REQUIRED AT OTHER TIMES, THE CONTRACTOR WILL BE SHEET A-647_2 A-647 PLAN VIEW RESPONSIBLE FOR ALL COSTS INCURRED BY THE FKAA FOR SUCH INSPECTIONS. SHEET A-647_3 A-647 EXISTING CONDITIONS C. THE CONTRACTOR SHALL NOT INTERRUPT SERVICE TO CUSTOMERS WHILE MAKING CONNECTIONS TO EXISTING COLLECTION SYSTEM UNLESS AUTHORIZED BY THE FKAA. SUCH SHEET A-647_4 A-647 PROPOSED REPAIR/REPLACEMENT TIE-INS SHALL BE SCHEDULED WITH THE FKAA 48 HOURS IN ADVANCE. CONTRACTOR MAY BE REQUIRED IN CERTAIN INSTANCES TO SCHEDULE HIS WORK AT OFF-PEAK HOURS. SHEET A-939_1 A-939 SITE OVERVIEW D. THE CONTRACTOR SHALL METER ALL WATER TAKEN FROM FKAA WATER MAINS FOR FLUSHING, TESTING AND DISINFECTION OF MAINS. METERS MUST BE OBTAINED FROM FKAA. SHEET A-939_2 A-939 PLAN VIEW E. THE CONTRACTOR SHALL HAVE A SUPERVISOR PRESENT ON THE JOB SITE AT ALL TIMES WHO IS CAPABLE OF SPEAKING, READING AND WRITING IN THE ENGLISH LANGUAGE. SHEET A-939_3 A-939 EXISTING CONDITIONS F. NO REVISIONS SHALL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE FKAA ENGINEERING DEPARTMENT. SHEET A939_4 A-647 PROPOSED REPAIR/REPLACEMENT G. LOCATION OF EXISTING UTILITIES HAS BEEN PREPARED FROM THE MOST RELIABLE DATA AVAILABLE TO THE ENGINEER. HOWEVER, THIS INFORMATION IS NOT GUARANTEED AND IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION, CHARACTER, AND DEPTH OF ANY EXISTING UTILITIES. EXTREME CAUTION SHALL BE EXERCISED SHEET V-4155_1 V-4155 SITE OVERVIEW TO PREVENT DAMAGE TO EXISTING UTILITIES. REPAIRS TO DAMAGED UTILITIES WILL BE MADE BEFORE CONSTRUCTION CONTINUES. SHEET V-4155_2 V-4155 PLAN VIEW H. NO EXCAVATION SHALL BE PERMITTED IN THE AREA OF THE TRANSMISSION PIPELINE WITHOUT AN FKAA REPRESENTATIVE AT THE SITE. SHEET V-4155_3 V-4155 EXISTING CONDITIONS I. CONSTRUCTION SHALL BE PERFORMED IN SUCH A MANNER AS TO PROVIDE A MINIMUM OF INCONVENIENCE TO THE OCCUPANTS AND RESIDENTS OF THE AREA. AT NO TIME SHALL SHEET V-4155_4 V-4155 PROPOSED REPAIR/REPLACEMENT THE ROADWAYS BE BLOCKED WITHOUT PROVIDING A WELL MARKED AND EASILY ACCESSIBLE ALTERNATE ROUTE. SIGNS AND MARKINGS SHALL BE PROVIDED IN DESIGN STANDARDS. (TOPIC #625-010-003-6). CONTRACTOR SHALL SUBMIT TO THE FKAA A MAINTENANCE OF TRAFFIC (M.O.T.) PLAN THAT SHOWS THE SCHEME(S) THAT IS INTENDED FOR USE ONSITE. THIS SHEET K-100_1 K-100 SITE OVERVIEW SHALL INCLUDE BARRICADES, SIGNING, AND/OR TEMPORARY STRIPING. A 24 HOUR/DAY CONTACT NAME AND PHONE NUMBER SHALL ALSO BE PROVIDED TO THE FKAA CONTRACT OFFICE. BOTH M.O.T. PLAN AND CONTACT SHALL BE UPDATED AS NEEDED. ALL FLAG PERSON OPERATIONS WILL BE IN STRICT COMPLIANCE WITH F.D.O.T. REGULATIONS. SHEET K-100_2 K-100 PLAN VIEW J. THE CONTRACTOR SHALL NOT OPERATE ANY SEWER MAIN VALVE OR MAKE A TAP ON ANY SEWER MAIN UNLESS AN FKAA REPRESENTATIVE IS PRESENT. SHEET K-100_3 K-100 EXISTING CONDITIONS K. THE CONTRACTOR SHALL SUBMIT A BAR CHART SCHEDULE OF CONSTRUCTION ACTIVITIES INDICATING ALL ITEMS OF WORK, COMMENCEMENT AND COMPLETION DATES. THE SHEET K-100_4 K-100 PROPOSED REPAIR/REPLACEMNT SCHEDULE WILL BE SUBMITTED FIVE (5) WORKING DAYS PRIOR TO THE PRE-CONSTRUCTION MEETING WITH FKAA. L. SEWER MAINS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SEWER. WHEN IT IS NOT POSSIBLE TO OBTAIN THE PROPER VERTICAL SEPARATION AND THE WATER MAIN IS ABOVE THE SEWER, MAINTAIN A MINIMUM VERTICAL SEPARATION OF 6 INCHES AND INSTALL THE WATER MAIN SO THAT THE JOINTS ARE EQUIDISTANT AND AS FAR AS POSSIBLE (NOT LESS THAN 10 FEET) FROM THE SEWER. M. INSTALL SEWER MAINS WITH A MINIMUM 30 INCHES OF COVER. IF IT BECOMES NECESSARY TO INSTALL A WATER MAIN WITH LESS THAN 24 INCHES OF COVER, THE WATER MAIN SHALL BE CONSTRUCTED OF CLASS 350 DUCTILE IRON PIPE PER AWWA C151. NEVER INSTALL A SEWER MAIN WITH LESS THAN 20 INCHES OF COVER. N. SEWER MAINS SHALL BE LAID AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING WATER MAINS. THE DISTANCE SHALL BE MEASURED EDGE TO EDGE. IN CASES WHERE IT IS NOT PRACTICAL TO MAINTAIN A 10 FOOT SEPARATION, THE SEWER MAIN MAY BE INSTALLED CLOSER TO THE WATER MAIN ( NOT LESS THAN 5 FEET), PROVIDED THAT THE SEWER MAIN IS LAID IN A SEPARATE TRENCH OR AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE WATER MAIN AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. P. ALL WORK MUST CONFORM TO FKAA MINIMUM DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS, LATEST REVISION. CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA NOTES & DRAWING INDEX NOTES N.T.S. OPERATIONS A-647 SITE OVERVIEW (BOCA CHICA KEY) CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA A-647 SITE OVERVIEW A-647_1 N.T.S. OPERATIONS FORRESTAL AVE HORNET AVE HORNET AVE LS A-647 TICONDEROGA AVE SARATOGA AVE TICONDEROGA AVE HORNET AVE RANDOLF LANGLEY AVE NOTE: PLAN VIEW PROVIDED TO ILLUSTRATE APPROXIMATE LIFT STATION LOCATION AND INFLUENT & EFFLUENT ROUTING ONLY. IT IS NOT INTENDED TO REPRESENT ALL UTILITIES AND CONFLICTS PRESENT. CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA A-647 PLAN VIEW A-647_2 N.T.S. OPERATIONS LS A-647 Wet Well LS A-647 Valve Box 1 LS A-647 Valve Box 2 LS A-647 Site 1 LS A-647 Site 2 LS A-647 Site 3 CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA A-647 EXISTING CONDITIONS A-647_3 N.T.S. OPERATIONS PLUG VALVE PLUG VALVE REPLACEMENT SCOPE 15012 AND 15018 PUMP BASE ASSEMBLIES: Myers base assembly model SRA44HH CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA A-647 PROPOSED REPAIR/REPLACEMENT A-647_4 N.T.S. OPERATIONS A-939 SITE OVERVIEW (BOCA CHICA KEY) CAD MAP # - 1-071, 1-060, 2-009 DRAWN: DATE: FKAA PROJECT NO. REVISIONS LBB 03/05/2018 APPROVALS DRAWING TITLE 4072-17 DATE MARKBY DESCRIPTION CHECKED: DATE: FLORIDA KEYS AQUEDUCT AUTHORITY FKAA DRAWING NO. B-3062 JCD 03/05/2018 1100 KENNEDY DRIVE NAVY SYSTEMS UPGRADES DESIGN: DATE: ENGINEERING WASTEWATER PUMPING SYSTEMS FKAA NavySystemsUpgradeWW_ FILE ID. LBB 03/05/2018 LOWER KEYS B-3062_CONST.dwg SCALE: SHEET KEY WEST, FLORIDA A-939 SITE OVERVIEW A-939_1 N.T.S. OPERATIONS MIDWAY AVE LS A-939 POST OFFICE NOTE: PLAN VIEW PROVIDED TO ILLUSTRATE APPROXIMATE LIFT STATION LOCATION AND INFLUENT & EFFLUENT ROUTING ONLY.