Fluorescence Off-On Sensors for F-, K+, Fe3+, and Ca2+

Binglin Sui University of Central Florida

Part of the Chemistry Commons Find similar works at: https://stars.library.ucf.edu/etd University of Central Florida Libraries http://library.ucf.edu

This Doctoral Dissertation (Open Access) is brought to you for free and open access by STARS. It has been accepted for inclusion in Electronic Theses and Dissertations, 2004-2019 by an authorized administrator of STARS. For more information, please contact [email protected].

STARS Citation Sui, Binglin, " Off-On Sensors for F-, K+, Fe3+, and Ca2+ Ions" (2014). Electronic Theses and Dissertations, 2004-2019. 1250. https://stars.library.ucf.edu/etd/1250 FLUORESCENCE OFF-ON SENSORS FOR F-, K+, Fe3+, AND Ca2+ IONS

by

BINGLIN SUI M.S. Southwest University, China, 2009

A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the Department of Chemistry in the College of Sciences at the University of Central Florida Orlando, Florida

Fall Term 2014

Major Professor: Kevin D. Belfield

© 2014 Binglin Sui

ii

ABSTRACT

Fluorescence spectroscopy has been considered to be one of the most important research techniques in modern , biochemistry, and biophysics. At present, fluorescence is a dominant methodology widely used in a great number of research domains, including biotechnology, medical diagnostics, genetic analysis, DNA sequencing, flow cytometry, and forensic analysis, to name just a few. In the past decade, with the rapid development of fluorescence microscopy, there has been a considerable growth in applying fluorescence technique to cellular imaging. The distinguished merits of fluorescence techniques, such as high sensitivity, non- invasiveness, low cytotoxicity, low cost, and convenience, make it a promising tool to replace radioactive tracers for most biochemical measurements, avoiding the high expense and difficulties of handling radioactive tracers.

Among the wide range of applications of fluorescence technique, fluorescent sensing of various cations and anions is one of the most important and active areas.

This dissertation is all about developing fluorescent sensors for physiologically significant ions, including F-, K+, Fe3+, and Ca2+. All of these sensors demonstrate fluorescence “turn-on” response upon interacting with their respective ions, which makes them much more appealing than those based on fluorescence quenching mechanisms.

In Chapter II, a novel highly selective fluorescence turn-on F- sensor (FS), comprised of a fluorene platform serving as the chromophore, and two 1,2,3-triazolium

iii

groups functioning as the signaling moieties, is described. The function of FS is established on the basis of deprotonation of the C-H bonds of 1,2,3-triazolium groups, which makes FS the first reported anion sensor based on the deprotonation of a C-H bond. Easy-to-prepare test strips were prepared for determining F- in aqueous media, providing an inexpensive and convenient approach to estimate whether the concentration of F- contained in drinking water is at a safe level.

Chapter III contains an optimized synthesis of a reported K+-selective group (TAC), and the development of two TAC-based fluorescence turn-on K+ sensors (KS1 and

KS2). The synthetic route of TAC is shortened and its overall yield is enhanced from 3.6% to 19.5%. Both KS1 and KS2 exhibited excellent selectivity toward K+ over other physiological metal cations, high sensitivity for K+ sensing, and pH insensitivity in the physiological pH range. Confocal fluorescence microscopy experiments demonstrate that they are capable of sensing K+ within living cells. 2PA determination reveals that

KS2 has a desirable 2PA cross section of 500 GM at 940 nm, which makes it a two- photon red-emitting fluorescent sensor for K+.

Chapter IV describes the development of a novel BODIPY-based fluorescence turn-on Fe3+ sensor (FeS). FeS is a conjugate of two moieties, a BODIPY platform serving as the and a 1,10-diaza-18-crown-6 based cryptand acting as the

Fe3+ recognition moiety. FeS displays good selectivity, high sensitivity, reversibility, and pH insensitivity toward Fe3+ sensing. Based on its excellent performance in determining

Fe3+ and very low cytotoxicity, FeS was effectively applied to sensing Fe3+ in living cells.

iv

In Chapter V, a new BODIPY-based fluorescence turn-on sensor (CaS) was designed and synthesized for selectively and sensitively determining Ca2+. CaS is comprised of two moieties, a BODIPY fluorophore and a Ca2+ complexing unit. CaS demonstrated selective fluorescence turn-on response towards Ca2+ over other biological metal cations. Moreover, CaS exhibited desirable sensitivity for Ca2+ detection, which makes it more suitable for extracellular Ca2+ determination. In addition, CaS was insensitive to the pH of the physiological environment, especially in the pH range of blood and serum. Therefore, CaS has potential to be applied to sensing Ca2+ ions in extracellular environments.

Chapter VI discusses potential future work of KS2 and CaS, following the results achieved in this dissertation. Based on the desirable performances of both sensors in sensing their respective ions, future work could largely be focused on their applications in cellular imaging.

v

To my parents

vi

ACKNOWLEDGMENTS

First and foremost, I must give my sincerest thanks to my advisor, Dr. Kevin D.

Belfield, without whom this dissertation would never have been possible. It was Dr.

Belfield who opened the door and paved the way for me to achieve all the fruits during my PhD study. Today, I can still clearly remember the first conversation we had in his office on Aug. 15th, 2011. His words motivated me to try my best every minute in the past three years. They will keep motivating me in my future life. In the process of my research, there was full of Dr. Belfield’s enlightenment, guidance, support, encouragement, patience, and enthusiasm. For me, Dr. Belfield is not only a PhD advisor but also a career mentor.

I thank Dr. Aniket Bhattacharya, Dr. D. Howard Miles, Dr. Shengli Zou, and Dr.

Andrew Frazer for being my committee members.

I also thank all the members of our research group for the friendly laboratory atmosphere they created, which made us a big harmonious family. Special thanks to

Bosung Kim, Xiling Yue, and Simon Tang for the collaboration and help.

vii

TABLE OF CONTENTS

LIST OF FIGURES ...... xii

LIST OF TABLES ...... xvii

LIST OF SCHEMES ...... xviii

LIST OF ACRONYMS AND ABBREVIATIONS ...... xx

CHAPTER I : BACKGROUND AND INTRODUCTION...... 1

I.1 Introduction to Fluorescence ...... 1

I.2 Fluorescence Sensing ...... 4

I.3 Metal Cation Sensing ...... 5

I.4 Anion Sensing ...... 10

I.4.1 Anion recognition ...... 12

I.4.2 Anion sensors ...... 14

I.5 Click Chemistry ...... 18

I.5.1 Application of click chemistry in anion recognition ...... 18

CHAPTER II : A FLUORESCENCE TURN-ON SENSOR FOR F- ...... 20

II.1 Introduction ...... 20

II.2 Results and Discussion ...... 26

II.3 Conclusion ...... 39

viii

II.4 Experimental ...... 40

II.4.1 General ...... 40

II.4.2 Synthesis ...... 40

II.4.3 Preparation of test strips ...... 46

CHAPTER III : FLUORESCENCE TURN-ON SENSORS FOR K+...... 47

III.1 Introduction ...... 47

III.2 Results and Discussion ...... 53

III.2.1 Potassium sensor 1 (KS1) ...... 58

III.2.2 Potassium sensor 2 (KS2) ...... 64

III.3 Conclusion ...... 72

III.4 Experimental ...... 72

III.4.1 General ...... 72

III.4.2 Synthesis ...... 73

III.4.3 Cell culture for imaging ...... 81

CHAPTER IV : A FLUORESCENCE TURN-ON SENSOR FOR Fe3+ ...... 82

IV.1 Introduction ...... 82

IV.2 Results and Discussion ...... 86

IV.3 Conclusion ...... 98

IV.4 Experimental...... 99 ix

IV.4.1 General ...... 99

IV.4.2 Synthesis ...... 100

IV.4.3 Cell culture for imaging...... 104

CHAPTER V : A FLUORESCENCE TURN-ON SENSOR FOR Ca2+ ...... 105

V.1 Introduction ...... 105

V.2 Results and Discussion ...... 111

V.3 Conclusion ...... 116

V.4 Experimental...... 117

V.4.1 General ...... 117

V.4.2 Synthesis ...... 117

CHAPTER VI : FUTURE WORK ...... 121

VI.1 Potassium sensor KS2 ...... 121

VI.2 Calcium sensor CaS ...... 121

APPENDIX A: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER II

...... 123

APPENDIX B: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER III

...... 141

APPENDIX C: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER IV

...... 156

x

APPENDIX D: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER V

...... 169

APPENDIX E: COPYRIGHT PERMISSIONS ...... 178

LIST OF REFERENCES ...... 180

xi

LIST OF FIGURES

Figure I-1. Jablonski diagram...... 2

Figure I-2. Simplified Jablonski diagram for two-photon excitation...... 3

Figure II-1. UV-vis absorption spectra of FS (1.0 × 10-5 M) in DMSO upon addition of

200 equiv of various anions...... 29

Figure II-2. UV-vis spectral changes of FS (1.0 × 10-5 M) in DMSO observed upon addition of 0-200 equiv of F-...... 30

Figure II-3. (A) A photograph of FS (6.0 μM) in DMSO with 20 equiv. of various anions.

(B) Visual fluorescence responses of FS (6.0 μM) in DMSO with 20 equiv. of various anions under excitation at 365 nm using a hand-held UV lamp...... 31

Figure II-4. Fluorescence emission spectra of FS (6.0 μM) in DMSO upon the addition of 20 equiv. of various anions (λex = 385 nm)...... 32

Figure II-5. Fluorescence emission Changes for FS (6.0 μM) upon the addition of 0-

- 1000 equiv. of F in DMSO (λex = 385 nm)...... 32

Figure II-6. (A) Fluorescence intensity of FS as a function of the equiv. of ions.

Inset: enlargement corresponding to 0-20 equiv. of F-. (B) Plot of log FI (fluorescence intensity) versus log [F-] in the range of 4-10 equiv. of F-...... 34

Figure II-7. Partial 1H NMR (400 Hz) spectra of FS (5.0 mM) upon addition of F- in

DMSO-d6...... 35

Figure II-8. The appearance of FHF- signal in 1H NMR (400 Hz) titration spectra of FS

- (5.0 mM) upon addition of F in DMSO-d6...... 35

xii

13 - Figure II-9. Partial C NMR (101 Hz) spectra of FS upon adding F in DMSO-d6...... 36

Figure II-10. Fluorescence response of test strips under irradiation at 365 nm using a hand-held UV lamp while determining fluoride ions at different concentrations in aqueous solution...... 38

Figure III-1. Fluorescence emission spectra of KS1 (10 μM) in 5 mM HEPES buffer (pH

7.2)/MeCN (4:1, v/v) upon addition of various biological metal cations at their physiological concentrations: Li+ (1.0 mM), Na+ (150 mM), K+ (150 mM), Mg2+ (2.0 mM),

Ca2+ (2.0 mM), Zn2+ (50 μM), Cu2+ (50 μM), Fe3+ (50 μM), Co2+ (50 μM), Ni2+ (50 μM).

λex = 480 nm...... 60

Figure III-2. Enhancements in fluorescence emission spectra of KS1 (10 μM) in 5 mM

HEPES buffer (pH 7.2)/MeCN (4:1, v/v) upon continuous addition of 150 mM K+ ions.

Ionic strength was maintained at 150 mM by addition of NaCl. λex = 480 nm...... 61

Figure III-3. Fluorescence emission spectra of KS1 (10 μM) in H2O/MeCN (4:1, v/v) at different pH. λex = 480 nm...... 62

Figure III-4. Images of live U87MG cells in MEM medium (A-E), and in an MEM medium solution of nigericin (5 µM), ouabain octahydrate (10 µM), and bumetanide (10

µM) (F-J), at 0 min (A, F), 30 min (B, G), 60 min (C, H), 90 min (D, I), and 120 min (E, J) after incubation with KS1 (5 µM)...... 63

Figure III-5. Average fluorescence intensity of cell images as a function of time. (A) control experiment (Images III-4A to III-4E); and (B) cells treated with nigericin, ouabain octahydrate, and bumetanide (Images III-4F to III-4J)...... 64

xiii

Figure III-6. Fluorescence emission spectra of KS2 (10 μM) in 5 mM HEPES buffer (pH

7.2)/MeCN (3:1, v/v) upon addition of various biologically-important metal cations at their physiological concentrations: Li+ (1.0 mM), Na+ (150 mM), K+ (150 mM), Mg2+ (2.0 mM), Ca2+ (2.0 mM), Zn2+ (50 μM), Cu2+ (50 μM), Fe3+ (50 μM), Co2+ (50 μM), Ni2+ (50

μM). λex = 600 nm...... 67

Figure III-7. Absorption spectra of KS2 (10 μM) in 5 mM HEPES buffer (pH 7.2)/MeCN

(3:1, v/v) upon progressive addition of K+...... 68

Figure III-8. Fluorescence emission spectra of KS2 (10 μM) in 5 mM HEPES buffer (pH

+ 7.2)/MeCN (3:1, v/v) upon progressive addition of K . λex = 600 nm...... 69

Figure III-9. Fluorescence emission spectra of KS2 (10 μM) in H2O/MeCN (3:1, v/v) as a function of pH. λex = 600 nm...... 70

Figure III-10. One-photon absorption (red) and 2PA (green circles) spectra of KS2. ... 71

Figure IV-1. UV-vis absorption spectra of FeS (7 µM) in H2O-CH3CN (9:1, v/v) upon addition of 100 equiv. of various metal cations...... 88

Figure IV-2. UV-vis spectral changes of FeS (7 µM) in H2O-CH3CN (9:1, v/v) observed upon addition of 1-700 equiv. of Fe3+ ions...... 89

Figure IV-3. Visual fluorescence responses of FeS (7 µM) in H2O-CH3CN (9:1, v/v) upon addition of 100 equiv. of various metal cations with excitation at 365 nm using a hand-held UV lamp...... 90

Figure IV-4. Fluorescence emission spectra of FeS (7 µM) in H2O-CH3CN (9:1, v/v) upon addition of 100 equiv. of various metal cations. Inset: Emission intensity of fluorescence emission triggered by different metal cations. 1, blank; 2, Li+; 3, Na+; 4, K+; xiv

5, Rb+; 6, Cs+; 7, Mg2+; 8, Ca2+; 9, Sr2+; 10, Ba2+; 11, Cr3+; 12, Mn2+; 13, Fe2+; 14, Fe3+;

15, Co2+; 16, Ni2+; 17, Cu2+; 18, Zn2+; 19, Ag+; 20, Cd2+; 21, Hg2+; 22, Pb2+; 23, Nd3+; 24,

3+ 3+ Sm ; 25, Er .λex = 480 nm...... 91

Figure IV-5. Enhancements in fluorescence emission spectra of FeS (7 µM) in H2O-

3+ CH3CN (9:1, v/v) upon continuous addition of 1-700 equiv. of Fe ions. λex = 480 nm. 92

Figure IV-6. (A) Fluorescence emission intensity of FeS as a function of the equiv. of

3+ 3+ added Fe . (B) Plot of FI-FI0 (FI: fluorescence intensity) versus the equiv. of Fe in the range of 1-20 equiv. of Fe3+ ions...... 93

Figure IV-7. Fluorescence response reversibility of FeS (7 µM) in H2O-CH3CN (9:1, v/v).

Fluorescence emission spectra of free FeS, FeS with 20 equiv. of Fe3+, and FeS with 20

3+ equiv. of Fe and 60 equiv. of TPEN. λex = 480 nm...... 94

Figure IV-8. Fluorescence emission spectra of FeS (7 μM) in H2O-MeCN (9:1, v/v) at different pH. λex = 480 nm...... 95

Figure IV-9. Viability of HCT-116 cells incubated with different concentrations of FeS. 96

Figure IV-10. Images of live HCT-116 cells in a 30 µM Fe3+ solution in MEM medium (a- c) and in only MEM medium (d-f) at 0 min (a, d) and 60 min (b, e) after incubated with

FeS (20 µM). Images c and f are the phase contrast images of b and e, respectively. . 97

Figure IV-11. Average fluorescence intensity of cell images at different time points. (A)

Control experiment; (B) Fe3+ sensing experiment...... 98

Figure V-1. Fluorescence emission spectra of CaS (5 μM) in 30 mM HEPES buffer (pH

7.4) upon addition of various biological metal cations at their physiological concentrations: Li+ (1.0 mM), Na+ (150 mM), K+ (150 mM), Mg2+ (2.0 mM), Ca2+ (1.0 xv

2+ 2+ 3+ 2+ 2+ mM), Zn (50 μM), Cu (50 μM), Fe (50 μM), Co (50 μM), Ni (50 μM). λex = 480 nm...... 113

Figure V-2. Absorption spectra of CaS (5 μM) in 30 mM HEPES buffer (pH 7.4) upon continuous addition of 7.0 mM Ca2+ ions...... 114

Figure V-3. Enhancement in fluorescence emission spectra of CaS (5 μM) in 30 mM

2+ HEPES buffer (pH 7.4) upon continuous addition of 7.0 mM Ca . λex = 480 nm...... 115

Figure V-4. Fluorescence emission spectra of CaS (5 μM) in water at different pH. λex =

480 nm...... 116

xvi

LIST OF TABLES

Table I-1. Radii of isoelectronic anions and cations...... 12

Table III-1. Optimization of reaction conditions for the synthesis of 40.a ...... 58

xvii

LIST OF SCHEMES

Scheme I-1. Schematic illustration of the conceptual mechanism and components of fluorescent sensors...... 5

Scheme I-2. Response mechanism of a FRET probe (1) for Zn2+. Ref 21, copyright

2013 American Chemical Society...... 7

Scheme I-3. Response mechanism of an ICT probe (2) for Ca2+. Ref 21, copyright 2013

American Chemical Society...... 8

Scheme I-4. Response mechanism of a PET probe (3) for Zn2+. Ref 21, copyright 2013

American Chemical Society...... 10

Scheme I-5. Structures of compounds 4, 5, 6, and 7...... 13

Scheme I-6. Structures of anion binding compounds 8, 9, and 10...... 14

Scheme I-7. Structures of compounds 11 and 12...... 15

Scheme I-8. Structures of compounds 13 and 14...... 17

Scheme I-9. Proposed scheme for CuAAC reactions. Ref 260, copyright 2004 American

Chemical Society...... 18

Scheme I-10. The structure of compound 15...... 19

Scheme II-1. The binding of compound 16 with fluoride ion. Ref 287, copyright 2002

The Royal Society of Chemistry...... 22

Scheme II-2. The structure of compound 17...... 23

Scheme II-3. The structure of compound 18...... 24

xviii

Scheme II-4. The reaction of compound 19 with fluoride ion. Ref 309, copyright 2012

American Chemical Society...... 24

Scheme II-5. The deprotonation of compound 20 by fluoride ion. Ref 315, copyright

2010 American Chemical Society...... 25

Scheme II-6. Synthetic route of FS.a ...... 28

Scheme III-1. The structure of PBFI...... 49

Scheme III-2. Structures of compounds 30 and 31...... 50

Scheme III-3. Structures of TAC and compound 32...... 50

Scheme III-4. Structures of compounds 33 and 34...... 52

Scheme III-5. Reported synthetic route of TAC.a ...... 54

Scheme III-6. Optimized synthetic route of TAC.a...... 56

Scheme III-7. Synthetic route for KS1.a ...... 59

Scheme III-8. Synthetic route for KS2.a ...... 66

Scheme IV-1. Structures of compounds 47 and 48...... 83

Scheme IV-2. Structures of compounds 49 and 50...... 84

Scheme IV-3. Synthetic route of FeS.a ...... 87

Scheme V-1. Structures of Stil-1, Stil-2, Indo-1, Fura-1, Fura-2, Fura-3, Rhod-1, Rhod-2.

...... 107

Scheme V-2. Structures of Fluo-1, Fluo-2, and Fluo-3...... 108

Scheme V-3. Structures of compounds 56, 57, 58, and 59...... 110

Scheme V-4. Synthetic route of CaS.a ...... 112

xix

LIST OF ACRONYMS AND ABBREVIATIONS

1H Hydrogen 1 isotope

1PA One-photon absorption

2PA Two-photon absorption

2PFM Two-photon fluorescence

microscopy

13C Carbon 13 isotope

Ǻ Angstrom (10-10 m)

ACN Acetonitrile

AcO- Acetate ion

AIDS Acquired immunodeficiency

syndrome

AM Acetoxymethyl

APCI Atmospheric pressure chemical

ionization

Ar Argon atm. Atmospheric pressure

ATP Adenosine triphosphate

BAPTA 1,2-Bis(o-aminophenoxy)ethane-

N,N,N’,N’-tetraacetic acid

- BF4 Tetrafluoroborate anion

xx

BH3/THF Borane tetrahydrofuran complex

BODIPY 4,4-Difluoro-4-bora-3a,4a-diaza-

s-indacene

BrCH2CH2Br 1,2-Dibromoethane

+ n-Bu4N Tetrabutylammonium ion n-BuLi n-Butyllithium t-BuOK Potassium tert-butoxide t-BuONa Sodium tert-butoxide

CaCO3 Calcium carbonate calcd Calculated

CaS Calcium sensor

CD2Cl2 Deuterated dichloromethane

CDCl3 Deuterated chloroform

CH2Cl2 Dichloromethane

CH3CN Acetonitrile

Cs2CO3 Cesium carbonate

CuAAC Copper(I) catalyzed azide alkyne

Huisgen cycloaddition

CuI Copper(I) iodide d Days or doublet

DART Direct analysis in real time

xxi

DCM Dichloromethane dd Doublet-doublet

DDQ 2,3-Dichloro-5,6-dicyano-1,4-

benzoquinone

DMF N,N-Dimethylformamide

DMSO Dimethyl sulfoxide

DMSO-d6 Deuterated dimethyl sulfoxide

DNA Deoxyribonucleic acid

DODC 3,6-Dioxaoctanedioic acid

dichloride

DPBS Dulbecco's phosphate-buffered

saline dppf 1,1′-Bis(diphenylphosphino)-

ferrocene

EGTA Ethylene glycol-bis(2-

aminoethylether)-N,N,N′,N′-

tetraacetic acid

Em Emission

EPA Environmental protection agency equiv. Equivalent

ESI Electrospray ionization

xxii

EtOH Ethanol

Ex Excitation

FeCl3·6H2O Iron(III) chloride hexahydrate

FeCl3/C A mixture of FeCl3 and activated

carbon

FeS Iron sensor

FHF- Bi-fluoride ion

FI Fluorescence intensity

FRET Fluorescence resonance energy

transfer

FS Fluoride sensor g Grams

GM Goppert-Mayer unit for the 2PA

cross section (1 × 10-50 cm4 s

photon-1·molecule-1) h Hours

H2NNH2·H2O Hydrazine monohydrate

HCT-116 cells Epithelial colorectal carcinoma

cells

HEPES 4-(2-Hydroxyethyl)-1-

piperazineethanesulfonic acid

xxiii

HOMO Highest occupied molecular

orbital

HR-MS High resolution mass

spectrometry

Hz Hertz

ICT Internal charge transfer

J Coupling constant

K2CO3 Potassium carbonate

KF Potassium fluoride

KI Potassium iodide

KS1 Potassium sensor 1

KS2 Potassium sensor 2

L Liter

LC-MS Liquid chromatography-mass

spectrometry

Lit. Literature

LUMO Lowest unoccupied molecular

orbital m Multiplet

M-1 L/mol (liter per mole)

MALDI Matrix-assisted laser

xxiv

desorption/ionization

MCL Maximum contaminant level

Me3O·BF4 Trimethyloxonium

tetrafluoroborate

MeCN Acetonitrile

MEM Minimal essential medium

MeOH Methanol

MgSO4 Magnesium sulfate

MHz Mega Hertz

μM Micromole per liter (10-6 moles

per liter) min Minute mL Milliliter (10-3 L) mM Millimolar mm2 Square millimeters mmol Millimoles (10-3 moles)

MS Mass spectrum

Na2CO3 Sodium carbonate

NaCl Sodium chloride

NaH Sodium hydride

NaHCO3 Sodium bicarbonate

xxv

NaI Sodium iodide

NaN3 Sodium azide

NaOH Sodium hydroxide

NH4OAc Ammonium acetate

NIR Near infrared

NIS N-iodosuccinimide nm Nanometer (10-9 m) nM Nanomolar

NMR Nuclear magnetic resonance

PBFI Potassium-binding benzofuran

isophthalate

Pd/C Palladium on carbon

Pd(dba)2 Bis(dibenzylideneacetone)

palladium(0)

Pd(PPh3)2Cl2 Bis(triphenylphosphine)

palladium(II) dichloride

Pd(PPh3)4 Tetrakis(triphenylphosphine)

palladium(0)

PEG Polyethylene glycol

PET Photo-induced electron transfer

POCl3 Phosphorus(V) oxychloride

xxvi

ppm Parts per million

R2 R-squared value

RNA Ribonucleic acid

RPMI Roswell park memorial institute s Seconds or singlet

SOCl2 Thionyl chloride t Triplet

TAC [2.2.3]-Triazacryptand

TEA Triethylamine

TFA Trifluoroacetic acid

THF Tetrahydrofurane

TLC Thin layer chromatography

TMS Tetramethylsilane

TOF Time of flight

TPEN N,N,N’,N’-Tetrakis(2-

pyridylmethyl)ethylenediamine

TsCl p-Toluenesulfonyl chloride

UV Ultraviolet v/v Volume/volume vis Visible wt % Weight percentage

xxvii

δ ppm or 2PA cross section

ε Molar absorption coefficient

λex Excitation wavelength

λmax Wavelength of maximum

absorption/emission

xxviii

CHAPTER I: BACKGROUND AND INTRODUCTION

I.1 Introduction to Fluorescence

As early as in 1565, the observation of fluorescence from a liquid solution was reported, in this instance by Nicolás Monardes, a Spanish physician and botanist, who found this phenomenon as a blue tinge of the infusion of a wood from Mexico and used it to attempt to treat kidney and urinary diseases, known as Lignum nephriticum (Latin for “kidney wood”).1-4 In the ensuing centuries, the unusual optical properties of the wood caught the interest of Kircher, Grimaldi, Boyle, Newton, Herschel, and many other scientists.1-2 Edward D. Clarke in 1819 and René Just Haüy in 1822 observed fluorescence in fluorites. David Brewster described the same phenomenon for chlorophyll in 1833. John Frederick William Herschel reported the first observation of fluorescence from a quinine solution in sunlight in 1845.5-6 In 1852, it was George

Gabriel Stokes who first introduced the term “fluorescence” in his report and correctly identified fluorescence as an emission process.7 Therefore, this work marked a milestone in fluorescence research. In the first lines of the paper, Stokes mentioned that his research was motivated by Herschel’s previous report about the quinine solution.

In 1935, Alexander Jablonski illustrated the processes that occur between the absorption and emission of light using a diagram, now known as a Jablonski diagram

(Figure I-1) named after Alexander Jablonski.8 Alexander Jablonski is regarded as the father of fluorescence spectroscopy because of his great accomplishments in this field.

Jablonski diagrams provide a theoretical basis for the development of fluorescence and

1

are often used as the starting point for discussing light absorption and emission. As the mechanism of fluorescence was widely understood, fluorescence received more and more attention and started to be explored as a technique.

Figure I-1. Jablonski diagram.

In the past three decades, there has been a dramatic growth in the application of fluorescence in the field of biological sciences. Fluorescence spectroscopy is considered to be one of the most important research tools in biochemistry and biophysics. At present, fluorescence is a dominant methodology widely used in a great number of research domains, including biotechnology, medical diagnostics, genetic analysis, DNA sequencing, flow cytometry, and forensic analysis, to name just a few.

Due to the high sensitivity of fluorescence detection, there has been a remarkable growth in the use of fluorescence for cellular imaging, which renders fluorescence techniques promising tools to replace radioactive tracers for most biochemical measurements, avoiding the high expense and difficulties of handling radioactive tracers. Moreover, fluorescence imaging can also effectively reveal the localization of intracellular molecules.

2

During the past 20 years, two-photon excitation techniques have emerged and grown rapidly.9 Usually, fluorescence is generated by absorbing a single photon with a wavelength within its conventional or linear absorption band. Pulsed lasers with femtosecond pulse widths are capable of exciting fluorophores through a two-photon absorption (2PA) process. 2PA is a simultaneous absorption of two photons of identical or different frequencies in order to excite a molecule from one state (usually the ground state) to a higher energy electronic state. The energy difference between the involved lower and upper states of the molecule is equal to the sum of the energies of the two photons. When the laser intensity is high enough, a fluorophore can simultaneously absorb two long-wavelength photons to reach the first singlet state

(Figure I-2). This process occurs only at the focal point of the laser beam. Such lasers have become convenient to use and integrated with microscopes. Two-photon excitation microscopy is a fluorescence imaging technique that allows imaging of living tissues at a very high depth, which can be up to two mm.10 Two-photon excitation microscopy can be a superior alternative to due to its efficient light detection, reduced phototoxicity, and deeper tissue penetration.

Figure I-2. Simplified Jablonski diagram for two-photon excitation. 3

I.2 Fluorescence Sensing

Fluorescence sensing of chemical and biological analytes is an active research field.11-15 The efforts devoted on this subject were initially driven by the desire to reduce the use of radioactive tracers. Nowadays, the high sensitivity of fluorescence sensing techniques is another important reason for attracting so much attention. Fluorescence sensing also meets the need for rapid and low-cost determination methods for a wide range of chemical, biochemical, clinical, and environmental processes.

Fluorescence sensing requires a change in a spectral property, such as fluorescence intensity, , excitation spectrum, fluorescence lifetime, or anisotropy, as a response to an analyte. The most popular fluorescence sensing approach is the fluorescence intensity based strategy, that is, fluorescence intensity of the probe changes in response to an analyte. A great number of this type of sensors have been developed for pH, cations, anions, DNA, RNA, ATP, enzymes, amino acids, glucose, etc.16-22

Typically, as illustrated in Scheme I-1, fluorescent probes are comprised of three different moieties: (1) a recognition moiety, responsible for the selective reaction with analyte; (2) a signaling unit, transducing the interaction between the recognition moiety and the analyte into fluorescence signal change; and (3) a suitable linker that connects the two former moieties.16,22-23 There are generally four types of reaction mechanisms between fluorescent probes and the corresponding analytes: (1) complexation; (2)

4

formation or cleavage of a covalent bond; (3) redox reaction; and (4) protonation- deprotonation.22

Scheme I-1. Schematic illustration of the conceptual mechanism and components of fluorescent sensors.

I.3 Metal Cation Sensing

Extensive efforts have been devoted to the development of fluorescent probes for various metal cations. The research on metal cation sensing can be traced back to the discovery of crown ethers and their ability to form complexes with metal cations.24-26

After Pedersen first reported the cation-complexing property of crown ethers in 1967, a large amount of subsequent work was performed to create more complex structures to bind a variety of metal cations.27-33 Among various metal cations, alkali and cations, especially Na+, K+, Mg2+, and Ca2+, attracted most of the public attention because of their well-known biological significance.27-28,30-63 With the discovery of the important roles that cations play in a myriad of biological and environmental processes, more and more attention began to be focused on developing

5

sensors for transition metal cations, such as Cr3+,64-66 Fe3+,67-75 Co2+,76-78 Ni2+,79-81

Cu2+,82-92 Zn2+,93-144 Pd2+,145-147 Ag+,148-161 Cd2+,162-176 Hg2+,177-200 and Pt2+.201

Complexation is the most widely used strategy to develop fluorescent sensors for various metal cations by virtue of their strong binding affinities with electronegative heteroatoms such as N, O, S.202 There are some general principles for probes based on this strategy: (1) matchable ring/cavity size for a given metal cation, e.g., crown ethers with different ring sizes bind different cations; (2) suitable ligands forming five- or six-membered ring complexes with metal cations, such as probes with an EGTA

(ethylene glycol tetra-acetic acid) unit complexing Ca2+; and (3) soft−hard acid−base principle, for instance, soft sulfur-containing receptors exhibit high affinities for soft metal cations such as Ag+ and Hg2+.

For transducing the complexation reaction into a fluorescence signal change, a photophysical process is necessarily involved. Fluorescence resonance energy transfer

(FRET), internal charge transfer (ICT), or photo-induced electron transfer (PET) is generally incorporated to translate cation recognition into a spectroscopic signal.

FRET is a mechanism describing energy transfer between a pair of different fluorophores, a fluorescence donor and a fluorescence acceptor. In the FRET process, the donor chromophore in its transfers its energy to a nearby ground state fluorescence acceptor through a non-radiative dipole-dipole coupling process. Then the excited acceptor fluorophore relaxes back to its ground state, emitting fluorescence.

FRET is mainly determined by four factors: (1) the spectral overlap between the emission spectrum of the donor and the absorption spectrum of the acceptor; (2) the 6

distance between the fluorescence donor and the acceptor; (3) the relative orientation of the donor and acceptor transition dipoles; and (4) the quantum yield of the donor.203-205

Scheme I-2 shows a FRET-based fluorescent probe (1) for Zn2+, which is a combination of fluorescein acting as the fluorescence donor and rhodamine as the acceptor.206 The emission spectrum of fluorescein overlaps well with the absorption spectrum of rhodamine. In compound 1, the rhodamine unit is in a spirolactam form that displays almost no absorption in the visible region. Consequently, no FRET occurs between the fluorescein and the rodamine moieties. When 1 is excited at 485 nm (the maximum absorption wavelength of fluorescein), only green fluorescence emission at 518 nm can be observed, which is a characteristic of fluorescein. However, in the presence of Zn2+, the rodamine moiety is turned into the ring-opened form, which exhibits an absorption peak at 560 nm. As a result, the FRET process occurs between the fluorescein and the rodamine moieties, and, thus, fluorescence emission at 590 nm emerges. It should be noted that the ring opening of rhodamine has proven to be an efficient way for developing various fluorescence off−on sensors for metal cations.207

Scheme I-2. Response mechanism of a FRET probe (1) for Zn2+. Ref 21, copyright 2013 American Chemical Society.

7

In probes based on the ICT process, an electron-donating group, which in most cases is an amino group, in the analyte recognition moiety is linked directly to a fluorophore, which acts as an electron-accepting unit. The lone pair electrons of the electron-donating group are in conjugation with the fluorophore. In such a “push-pull” case, excitation by light brings about a serious redistribution of electron density of the probe, i.e., ICT process from the electron donor to the fluorophore occurs.208-209 When binding with metal cations, both the energy gap between LUMO and HOMO of the molecule and the efficiency of ICT are changed, resulting in absorption and emission intensity changes as well as spectral shifts. Scheme I-3 shows a typical example of an

ICT-based probe, Fura 2 (2).210-211 Upon complexing with Ca2+, Fura 2 exhibits a remarkable blue-shifted fluorescence and increased fluorescence intensity.

Scheme I-3. Response mechanism of an ICT probe (2) for Ca2+. Ref 21, copyright 2013 American Chemical Society.

8

In PET probes, the analyte recognition moiety (the receptor) is often connected to a fluorophore via a spacer, rendering the receptor and the fluorophore unconjugated, which essentially differs from ICT-based probes. The electronegative atom, usually a nitrogen atom, contained in the receptor moiety has high-energy lone pair electrons, which can transfer an electron to the fluorophore in the excited state, resulting in fluorescence quenching to the fluorophore. Upon complexing metal cations, the reduction potential of the receptor is enhanced and, thus, the HOMO of the receptor becomes lower in energy than that of the fluorophore. As a result, the PET process from the receptor to the fluorophore is restricted, and consequently fluorescence quenching of the fluorophore is reduced, leading to increased fluorescence intensity of the fluorophore.16,212-213 Therefore, the PET mechanism has potential to be explored to develop fluorescence “turn-on” sensors. Scheme I-4 depicts a typical example of a PET probe, FluoZin-3 (3).214 In the absence of Zn2+, FluoZin-3 emits rather weak fluorescence because of the PET process from the receptor moiety to the fluorescein fluorophore. However, upon binding Zn2+ ions, fluorescence of the fluorophore can be considerably increased by prohibiting the PET process. FluoZin-3 has been applied to selective imaging of Zn2+ in living cells.214-215 Due to the advantages of fluorescence

“turn-on” sensors in cell imaging applications, the PET mechanism has been the most frequently applied one and is attracting more and more attention in developing various fluorogenic probes for metal cations.

9

Scheme I-4. Response mechanism of a PET probe (3) for Zn2+. Ref 21, copyright 2013 American Chemical Society.

I.4 Anion Sensing

Anion sensing chemistry can be traced back to the late 1960s, around almost the same time when the preparation and cation coordination studies of crown ethers were first reported by Pedersen.24 In the 1970s, cation coordination chemistry received a great deal of attention and cation recognition research began to attract considerable interest. As a result, both the academic study and industrial applications of cation sensing have been well developed. By contrast, little attention had been paid to anion recognition chemistry until the beginning of 1990s.216-217 In the last twenty years, substantial strides have been made in the field of anion recognition and detection. The rapid growth of this subject is attributed to the recognized significance of anions, which was previously underappreciated. Anions are ubiquitous and have been proven to play manifold and indispensable roles in a great number of chemical, biological, and 10

environmental processes.18,218-225 For example, it is well known that DNA and ATP are both polyanions; and the over use of phosphate compounds leads to the eutrophication of rivers.

The design of anion receptors is much more challenging compared with that of cation receptors, which is an important reason for the tardy development of anion detection. Anions have lower charge density (charge to ionic radius ratio) because of their larger sizes in comparison to their isoelectronic cations (Table I-1).226

Consequently, electrostatic binding interaction between anions and their respective receptors is much less effective than it would be for smaller isoelectronic cations.227 In addition, numerous anions are sensitive to pH, being protonated by H+ and, therefore, losing the negative charge. Thus, the probes must have the ability to perform the sensing function within the pH range of their target anion. Moreover, solvents also play a significant role in anion recognition. Anions are solvated in solution and strong hydrogen bonds are formed between anions and hydroxylic solvents. Therefore, a useful anion receptor must compete efficiently with the solvation of the target anion and/or hydrogen bonds. For instance, a neutral anion receptor based solely on ion- dipole interactions can only bind anions in aprotic solvents, whereas charged receptors, which have stronger interactions with anions, may be able to recognize highly solvated, even hydrated anions in protic solvents.

11

Table I-1. Radii of isoelectronic anions and cations. Cation r [Å] Anion r [Å]

Na+ 1.16 F- 1.19

K+ 1.52 Cl- 1.67

Rb+ 1.66 Br- 1.82

Cs+ 1.81 I- 2.06

I.4.1 Anion recognition

Based on the different mechanisms of interactions between anions and their receptors, these interactions can be divided into several categories, including electrostatic interactions, complexation with metal ions, hydrogen binding, and combinations of some of these interactions working together. Polyamines are the first anion receptors produced to recognize anions through electrostatic interactions between anions and positively charged receptors. About 40 years ago, Schmidtchen prepared macrotricyclic quaternary ammonium compounds 4 and 5.228-229 Receptor 4, which has an internal diameter of 4.6 Ǻ, was found to be able to hold iodide ion

(diameter: 4.12 Å), while larger anions such as p-nitrophenolate can be encapsulated within the macrotricycle of receptor 5 due to the larger cavity size of 5. It is necessary to point out that receptors on the basis of electrostatic interactions generally suffer from low selectivity for a specific anion due to the similar binding affinities of a receptor for its analyte and other anions with similar structures.230

12

Scheme I-5. Structures of compounds 4, 5, 6, and 7.

Another type of anion receptor is based on the interaction between anions and organometallic compounds. Electron-deficient metal ion centers can bind to anions through bonding interactions caused by orbital overlaps.227 By exploiting this strategy, macrocyclic anion receptors containing metal atoms such as mercury,231-235 germanium,236-237 and tin238-241 have been produced. Among these metals, mercury is an especially advantageous candidate for use in the construction of artificial anion hosts because it is able to form remarkably stable carbon-metal bonds extending collinearly from the mercury atom. Compound 6, a 10-membered pentamercuramacrocycle, is one of the most elegant examples of mercury-based anion receptors.232 It can bind halide ions, forming a flat plate-like macro-ring.

Hydrogen bonding is another dependable approach for anion recognition.

Compared with other approaches, hydrogen bonding has an important advantage. It allows for designing anion receptors with particular shapes that can potentially differentiate between anions with diverse geometries because hydrogen bonds are directional. Pascal reported the first anion receptor via hydrogen bonding in 1986.242

13

Compound 7 is a purely amide-based receptor that shows a capacity of binding fluoride in DMSO. Subsequently, various N-H-containing structures have been exploited as good donors for constructing receptors for anions, including amide, urea, thiourea, pyrrole, and indole.223-224,243-247 Compound 8 is capable of forming a complex

-1 248 with fluoride with a stability constant of 17200 M in CH2Cl2 and compounds 9 and 10

- 249 are able to bind very strongly with H2PO4 ion in DMSO.

Scheme I-6. Structures of anion binding compounds 8, 9, and 10.

I.4.2 Anion sensors

As the development of anion receptors has been growing rapidly, considerable attention has recently been focused on developing anion sensors with the goal of improving chemical sensor technology. These sensors are designed to have the capability of selectively recognizing certain anions and sensing the anion recognition event by providing a macroscopic optical or electrochemical response.250-252 As schematically shown in Figure I-3, an effective and widely adopted approach for designing anion sensors is to couple an anion receptor to certain groups which have the ability to signal the anion binding process. The role that the signaling units play in the 14

process is a transducer that transduces an anion recognition event into an electrochemical or optical signal.

Electrochemical anion detection is a well-studied approach among all kinds of anion sensing techniques. Three main strategies have proven effective for electrochemically sensing anions: 1) potentiometric anion sensors (extracting an anion into a membrane through a non-electroactive anion receptor and determining the resulting potential of the membrane); 2) voltammetric/amperometric anion sensors

(detecting the potential/current perturbation of a redox-active anion receptor upon anion binding); 3) chemically modified electrodes (attaching an anion receptor to an electrode through chemical reactions or electro-polymerization). For example, both compound 11 and compound 12 are electrochemical anion sensors based on Cp2Co/Cp2Co redox couple.253-255 Compound 11 is a good electrochemical sensor for AcO- ion, whereas

- - compound 12 is capable of sensing H2PO4 ion much better than AcO ion.

Scheme I-7. Structures of compounds 11 and 12.

15

In addition to electrochemical anion sensing, optical anion sensing is another technique for anion detection. Optical anion sensors are compounds that are capable of exhibiting changes in either fluorescence or color in the presence of certain anions.

Anion sensors displaying color changes are termed colorimetric anion sensors and those showing changes in fluorescence are named fluorescent anion sensors.

Using color changes as a signaling approach has been widely adopted since it does not require the use of a specific instrument as color changes can be directly observed by the naked eye. In this aspect, colorimetric sensors have apparent advantages over other types of molecular sensors. As a matter of fact, there are many examples of colorimetric sensors for anions, especially for fluoride ions.

It was reported by Sessler and co-workers that 2,3-dipyrrol-2'-ylquinoxalines, such as compound 13, can be explored as a class of anion sensors that are able to

256 detect fluoride ions in CH2Cl2 and DMSO. In fact, compound 13 demonstrated a remarkable color variation from clear yellow (λmax = 455 nm) to purple (λmax = 560 nm) on addition of fluoride ions, which was in agreement with the large binding stability constant found between compound 13 and fluoride ions, whereas other anions did not provide any noteworthy color change.

16

Scheme I-8. Structures of compounds 13 and 14.

The other branch of optical anion sensors is fluorescent anion sensors, which signal the anion recognition event by changing fluorescence properties. Compared with other types of chemical sensors, fluorescent sensors are advantageous for their high detection limit and high sensitivity, which has stimulated a great amount of interest in covalently attaching fluorophores in proximity to guest-recognition groups. Generally speaking, there are two modes of fluorescent sensors, fluorescence quenching (“on-off”) mode and fluorescence enhancing (“off-on”) mode. For fluorescent quenching sensors, the lack of high signal outputs seriously limit their application. Compound 14 was reported to be a good fluorescent sensor for phosphate ions.257 It provides multiple hydrogen bonding sites to generate a pseudo-tetrahedron cleft which can hold phosphate by forming a 1:1 complex. In comparison with other anions (F-, Cl-, Br-, SCN-,

- - - - AcO , NO3 , ClO4 , and HSO4 ), phosphate ions can be recognized by compound 14 in a highly selective manner. Upon the addition of phosphate ions, the fluorescent emission of compound 14 shifts from λmax = 477 nm to λmax = 377 nm.

17

I.5 Click Chemistry

Click chemistry is a term describing chemical synthesis tailored to quickly and reliably generate substances by joining small units together. The term was first coined in

1998 and fully described in 2001 by K. Barry Sharpless.258 Within the click chemistry concept, one of the most popular reactions is the copper(I) catalyzed azide alkyne

Huisgen cycloaddition (CuAAC) at room temperature,259 which was discovered independently and concurrently by Morten Meldal,260 Valery V. Fokin and K. Barry

Sharpless.261 Scheme I-9 shows the reaction scheme of CuAAC reaction proposed by

Valery V. Fokin and K. Barry Sharpless.262

Scheme I-9. Proposed scheme for CuAAC reactions. Ref 260, copyright 2004 American Chemical Society.

I.5.1 Application of click chemistry in anion recognition

With the emergence and fast development of the Cu(I)-catalyzed 1,3-dipolar cycloaddition of a terminal alkyne and an azide forming a 1,4-disubstituted 1,2,3-triazole ring,260-261 its application has been rapidly growing, particularly in the fields of synthetic,

18

medicinal, biological, and materials chemistry.263-270 After alkylation, the 1,2,3-triazole ring is transformed into a 1,2,3-triazolium group. The unique properties of the 1,2,3- triazole and 1,2,3-triazolium groups in terms of their abilities to participate in hydrogen bonding with anions has made click chemistry even more appealing. Compared with that of a 1,2,3-triazole ring, the hydrogen of a 1,2,3-triazolium group is much more acidic, and, consequently, has higher hydrogen bond donating ability due to the positive charge introduced in the process of the alkylation reaction. Compound 15 is a 1,2,3-

- triazolium-based anion receptor that shows remarkable ability to recognize H2PO4 ions through hydrogen bonding interactions.271

Scheme I-10. The structure of compound 15.

19

CHAPTER II: A FLUORESCENCE TURN-ON SENSOR FOR F-

Reproduced with permission from: Sui, B.; Kim, B.; Zhang, Y.; Frazer, A.; Belfield, K. D.

“Highly Selective Fluorescence Turn-On Sensor for Fluoride Detection” ACS Appl.

Mater. Interfaces 2013, 5, 2920-2923. Copy right [2013] America Chemical Society.

II.1 Introduction

Among biologically important anions, fluoride ion has caught particular attention because of its duplicitous nature. On one hand, fluoride has beneficial effects in dental health and treatment for osteoporosis.272-276 For this reason, fluoride anion salts are commonly used in toothpaste, water fluoridation, topical and systemic fluoride therapy for preventing and reducing tooth decay, and various products associated with oral hygiene. The fluoridation of water is considered as "one of 10 great public health achievements of the 20th century" by the U.S. Centers for Disease Control and

Prevention. On the other hand, pathological studies show that excessive fluoride intake can trigger adverse effects, such as dental and skeletal fluorosis,277 gastric and kidney disorders, and even cancers.278-279 The toxicity of fluoride ions involves the combination of fluoride with the calcium ions in blood, which are indispensable for the function of the nervous system, to form insoluble calcium fluoride, giving rise to hypocalcemia.

Moreover, cellular studies show that excessive fluoride uptake can result in cell growth inhibition and even cell apoptosis.280 Therefore, the U.S. Environmental Protection

Agency gives standards that an enforceable MCL (maximum contaminant level) for

20

fluoride in drinking water is 4.0 ppm to prevent osteofluorosis, and a non-enforceable secondary fluoride MCL is 2.0 ppm to protect against dental and skeletal fluorosis.

Owing to its significance for human health, the quantitative determination of the levels of fluoride is of growing interest. Ion chromatography and ion-selective electrode have been generally used in quantitative analysis of fluoride. However, these approaches involve disadvantages, for example, relatively complicated procedures and cumbersome equipment, high costs, extending operating time, etc. Therefore, optical sensors, especially fluorescent sensors, which are potential to be highly selective, sensitive, rapid, inexpensive, and convenient, have been designed for fluoride detection.281-296

Compound 16, a simple anthracene based urea derivative, was reported to be the first highly selective fluorescent chemosensor for fluoride ions.289 As shown in

Scheme II-1, the four N-H bonds of the two urea moieties are able to form a binding pocket, which can complex fluoride ions through hydrogen bonds. Compound 16 exhibits a selective fluorescent quenching effect only upon binding with fluoride ions in

ACN-DMSO mixture. Afterwards, a variety of urea/thiourea containing fluorescent sensors have been developed for fluoride ion detection.283,290-292

21

Scheme II-1. The binding of compound 16 with fluoride ion. Ref 287, copyright 2002 The Royal Society of Chemistry.

Another type of fluorescent fluoride sensors is designed on the basis of a well- known fact that fluoride ions have a high affinity to silicon. This unique chemical property has been widely applied in the development of various fluorescent sensors for fluoride ions.281-282,284,287-288,293-296 Compound 17 is an effective fluorescent sensor based on a BODIPY-coumarin platform for fluoride sensing.282 A triisopropylsilyl group is exploited as the potential reaction unit for fluoride ions because of the high reactivity of fluoride to silicon. Compound 17 exhibits an intense fluorescent emission band at 606 nm when excited at 420 nm. Upon reaction with fluoride ions, the triisopropylsilyl group is unmasked and compound 17 is converted into a deprotected product.

Correspondingly, addition of fluoride ions results in a considerable decrease in the emission at 606 nm and simultaneous emergence of a blue-shifted fluorescent emission band at 472 nm. Therefore, compound 17 is a ratiometric fluorescent sensor for fluoride ions.

22

Scheme II-2. The structure of compound 17.

Besides silicon, fluoride has also a high affinity to boron. This phenomenon has already been explored to develop fluoride sensors too. Since the first report about fluorescent sensing of fluoride ions using in 1998,297 many other fluorescent sensors based on the boron-fluoride interaction have been reported.298-310

Compared with boronic acids, the more stable triarylborons with high Lewis acidity have been proved to be more suitable for being explored as fluoride probes in aqueous or alcohol solvents because they have the ability to overcome the competitive binding of aqueous protons with fluoride ions.307-310 Moreover, diborane compounds have received more attention since they are more efficient at capturing fluoride ions than monoborane receptors.299,301-302,306-307 Compound 18 is bis-triarylboron based fluorescent sensor for fluoride ions.307 Compound 18 is highly fluorescent with a maximum emission wavelength at 414 nm. Upon the addition of fluoride ion, its fluorescence emission is dramatically quenched, which is due to the occupation of the empty pπ orbital of boron by F-.307 Therefore, Compound 18 is a “turn-off” sensor for fluoride ions.

23

Scheme II-3. The structure of compound 18.

Recently, a new fluorescence turn-on fluoride sensor, compound 19, is reported.311 The fluoride sensing function of compound 19 is established on the interaction between antimony and fluoride (Scheme II-4). Compound 19 is a stibonium salt, weakly fluorescent with an anthryl-based emission band at 427 nm. Upon binding to fluoride, its fluorescence emission intensity is highly increased, which makes it a good fluoride sensor even in aqueous environment.

Scheme II-4. The reaction of compound 19 with fluoride ion. Ref 309, copyright 2012 American Chemical Society.

24

As the most electronegative atom, fluoride has some unique chemical properties due to its small size and high charge density. Among various anions, fluoride ions have the highest affinity to protons and are capable of deprotonating hydrogen-containing polar moieties, such as O-H and N-H groups. These unique properties make fluoride sensors based on the deprotonation mechanism display high selectivity for F− over

- - - other competitive anions, such as H2PO4 , CN , and AcO , which generally interfere harmfully in sensing fluoride with hydrogen-bonding based fluoride sensors.312-316 As a result, a variety of N-H containing groups such as sulfonamide313, imidazole,315 urea314, and pyrrole316-317, have been exploited to construct deprotonation based fluoride sensors. As illustrated in Scheme II-5, the N-H group of compound 20, which is a 1,4- diketo-3,6-diphenylpyrrolo[3,4-c]pyrrole derivative, can be deprotonated by fluoride ions in CH2Cl2. Upon the addition of fluoride, a drastic decrease of the fluorescent emission band at 563 nm and the appearance of a red-shifted emission band at 635 nm were observed.317

Scheme II-5. The deprotonation of compound 20 by fluoride ion. Ref 315, copyright 2010 American Chemical Society.

25

On the basis of the foregoing background information, a novel fluorescence turn- on fluoride sensor (FS) is designed, taking advantage of the unique deprotonation ability of fluoride ions. As mentioned above, various fluoride sensors have been developed involving deprotonation of N-H groups.312-316 However, employing deprotonation of C-H bond for detecting fluoride ions is still a challenge owing to the low acidity of C-H bond.

Although Cao et al. attempted to use the deprotonation of C-H bond by fluoride to explain the problem they met,318 they failed to provide any evidence to support it. To the best of our knowledge, no anion sensors have been reported by exploiting the deprotonation of C-H bond before FS.

As explained in I.5.1, the acidity of the hydrogen of a 1,2,3-triazolium group is relatively high compared with other types of C-H bond. Consequently, it is potential to be deprotonated by anions, especially fluoride ions, which makes it a promising candidate for being exploited as an anion recognizer through the deprotonation mechanism instead of hydrogen bonding. By adopting the recognition moiety-signaling unit combination strategy, as demonstrated in Scheme I-1, we designed a conjugate of

1,2,3-triazolium groups and a fluorene derivative which serves as the fluorescent signaling unit.

II.2 Results and Discussion

As shown in Scheme II-6, the synthesis of FS started with 3,5-dibromobenzyl alcohol. It reacted with trimethylsilylacetylene via a Sonogashira coupling reaction to form compound 21, followed by a desilylation reaction with KF to produce compound 22. 26

Then the hydroxyl group of compound 22 was converted to chlorine by thionyl chloride, providing compound 23. Compound 24 was prepared through phosphonylation of the chloromethyl group of compound 23 with NaI as the catalyst. Compounds 25,319 26,320 and 27321 were synthesized according to reported literature procedures with 2,7- dibromofluorene as the starting material. Compound 28 was obtained from a Horner-

Wadsworth-Emmons reaction between compounds 24 and 27. Then it reacted with iodobenzene via a copper(I)-catalyzed alkyne-azide cycloaddition reaction to generate compound 29 in the presence of sodium ascorbate, N1,N2-dimethylethane-1,2-diamine, and NaN3 in a solvent mixture of DMSO:toluene:H2O (5:4:1). The methylation of compound 29 with 2.5 equiv. of Me3O·BF4 in anhydrous CH2Cl2 provided the final product FS in a yield of 35% after repeated recrystallization from chloroform.

27

Scheme II-6. Synthetic route of FS.a

a Reagents and conditions: (a) CuI, Pd(PPh3)2Cl2, trimethylsilylacetylene, THF:triethylamine (4:1), reflux, 12 h; (b) KF, methanol, room temperature, 10 h; (c) SOCl2, triethylamine, CH2Cl2, 0 °C, 30 min; then reflux, 2 h; (d) NaI, triethyl phosphite, acetone, 60 °C, 24 h; (e) 1-bromohexane, t-BuOK, DMF, 40 °C, 30 min; (f) diphenylamine, t-BuONa, Pd(dba)2, dppf, toluene, reflux, 16 h; (g) n-BuLi, THF, −78 °C, 40 min; then DMF, −78 °C, 1.5 h; (h) t-BuOK, THF, 0 °C, 30 min; then room temperature, 3 h; (i) iodobenzene, 1 2 NaN3, CuI, sodium ascorbate, N ,N -dimethylethane-1,2-diamine, toluene:DMSO:H2O (4:5:1), room temperature, 2 h; (j) trimethyloxonium tetrafluoroborate, CH2Cl2, room temperature, 3 d.

The photophysical and photochemical properties of FS were first examined with

UV-vis spectroscopy. FS exhibited an absorption peak at 398 nm in DMSO. A series of

28

------anions (F , Cl , Br , I , CN , OCN , SCN , N3 , NO2 , NO3 , ClO4 , IO4 , AcO , HSO4 , and

- + H2PO4 , as n-Bu4N salts) were added to the solution of FS to investigate its selectivity for certain anions. Figure II-1 shows the absorption spectra of FS before and after adding those anions. Upon the addition of fluoride ions, the absorption wavelength of

FS blue-shifted from 398 nm to 385 nm and the absorption intensity increased. In contrast, the addition of other anions brought about no considerable change to the absorption spectra of FS. These results indicate that FS displays remarkable selectivity for fluoride ions over the other anions. Moreover, as illustrated in Figure II-2, with the increasing of the equiv. of fluoride ions, both the absorption intensity and the maximum absorption wavelength of the absorption spectra of FS were changed gradually.

Figure II-1. UV-vis absorption spectra of FS (1.0 × 10-5 M) in DMSO upon addition of 200 equiv of various anions.

29

Figure II-2. UV-vis spectral changes of FS (1.0 × 10-5 M) in DMSO observed upon addition of 0-200 equiv of F-.

In addition to UV-vis spectroscopy, fluorescent emission spectroscopy was also utilized to investigate the photophysical and photochemical properties of FS.

Fluorescent emission spectroscopy is more effective and reliable than absorption spectroscopy for fluoride ions detection. The fluorescent emission properties of FS in the absence and presence of various anions were examined in DMSO. FS displayed a specific fluorescent emission response to fluoride ions, which was in good agreement with the results found in absorption spectroscopy experiments. Figures II-3A and II-3B show the pictures of FS before and after excitation at 365 nm using a hand-held UV lamp, respectively. The free FS is not fluorescent. Upon the addition of fluoride ions, a striking blue-green fluorescence was emitted. However, the addition of other anions 30

brought about no fluorescent emission and the samples with these anions displayed no change in solution colors before and after excitation at 365 nm.

Figure II-3. (A) A photograph of FS (6.0 μM) in DMSO with 20 equiv. of various anions. (B) Visual fluorescence responses of FS (6.0 μM) in DMSO with 20 equiv. of various anions under excitation at 365 nm using a hand-held UV lamp.

The fluorescence properties of FS in the absence and presence of various anions were further investigated with fluorescent emission spectroscopy. Figure II-4 shows fluorescence spectra of FS recorded with excitation at 385 nm in the presence of

20 equiv. of various anions. In agreement with the results obtained from visual fluorescence response experiments (Figure II-3B), FS with 20 equiv. of fluoride ions added displayed an intense fluorescent emission band at 498 nm with a high quantum yield up to 0.66. In contrast, no fluorescence signal was detected from the free FS and

FS with 20 equiv. of other anions. All these results demonstrate that FS exhibits very high selectivity for fluoride ions over other anions and it is promising to be used as a specific fluorescent sensor for fluoride ions. 31

Figure II-4. Fluorescence emission spectra of FS (6.0 μM) in DMSO upon the addition of 20 equiv. of various anions (λex = 385 nm).

Figure II-5. Fluorescence emission Changes for FS (6.0 μM) upon the addition of 0- - 1000 equiv. of F in DMSO (λex = 385 nm). 32

Following the fluoride selectivity experiments, the sensitivity of FS toward sensing fluoride ions was also examined with fluorescent emission spectroscopy. The fluorescence responses of FS induced by the addition of fluoride ions were determined with excitation at 385 nm in DMSO. As shown in Figure II-5, the fluorescent emission intensity increased gradually with the progressive addition of fluoride ions (from 0 to

1000 equiv.). The fluorescence intensity of FS as a function of the equiv. of fluoride ions is illustrated in Figure II-6A. The inset curve is an enlarged segment of Figure II-6A in correspondence to 0–20 equiv. of fluoride ions. As displayed in the inset, the addition of the first 4 equiv. of fluoride ions resulted in no fluorescent emission response in comparison to the free FS. However, a remarkable fluorescence emission was recorded after 5 equiv. of fluoride ions was added. As the added amount of fluoride ions increased, the fluorescent emission intensity was enhanced with the concentration of fluoride ions. In detail, the fluorescence intensity increased dramatically in the range of

4-10 equiv. of fluoride ions. After that, the increasing rate of the fluorescent emission intensity was reduced. More significantly, it was found that the plot of log(FI)

(fluorescence intensity) versus log[F-] (concentration of fluoride ions) is linear (R2 =

0.9985) in the range of 4-10 equiv. of fluoride ions (Figure II-6B). These results indicate that FS is a sensitive and effective sensor that can be utilized to determine the concentration of fluoride ions.

33

Figure II-6. (A) Fluorescence intensity of FS as a function of the equiv. of fluoride ions. Inset: enlargement corresponding to 0-20 equiv. of F-. (B) Plot of log FI (fluorescence intensity) versus log [F-] in the range of 4-10 equiv. of F-.

Before exploring applications of FS for fluoride ions determination, the interactions between FS and fluoride ion were further investigated by NMR titration experiments. The NMR spectra of FS were recorded with different equiv. of fluoride ions in DMSO-d6. Figure II-7 shows the partial 1H NMR fluoride ion titration spectra of FS in the presence of 0-20 equiv. of fluoride ions. Upon the addition of fluoride ions, the signal of triazolium CH protons (9.99 ppm) shifted downfield, gradually decreased, and eventually disappeared. As shown in Figure II-8, along with the changes of triazolium

CH proton signal, a significant triplet signal (1:2:1) at 16.1 ppm with a coupling constant of J ≈ 120 Hz emerged after 5 equiv. of fluoride ions was added. This is a characteristic

1H NMR signal of the bi-fluoride ion (FHF-), which proves the formation of FHF-.315,322-323

These results indicated that the CH group of the triazolium ring was deprotonated by fluoride.

34

Figure II-7. Partial 1H NMR (400 Hz) spectra of FS (5.0 mM) upon addition of F- in DMSO-d6.

Figure II-8. The appearance of FHF- signal in 1H NMR (400 Hz) titration spectra of FS - (5.0 mM) upon addition of F in DMSO-d6. 35

The results obtained from 1H NMR were also confirmed by the changes recorded in 13C NMR spectra of FS as a result of the addition of fluoride ions (Figure II-9).

Furthermore, the NMR results and the forgoing fact that the first fluorescence response of FS induced by fluoride ions was also detected right after the addition of 5 equiv. of fluoride ions suggest that the emergence of fluorescence emission originates from the deprotonation of the C-H bond.

13 - Figure II-9. Partial C NMR (101 Hz) spectra of FS upon adding F in DMSO-d6.

Based on all the results demonstrated above, a plausible explanation about the interactions between FS and fluoride ions is proposed here. Two different kinds of interactions, H-bonded complexation and deprotonation, are involved in the titration process of FS with gradually increased equiv. of fluoride. The first addition of fluoride ions produces hydrogen-bonding complexes, whereas subsequently added fluoride

36

leads to deprotonation of the triazolium groups. In the deprotonation process, bi-fluoride ion FHF- and two deprotonated species of FS, mono- and bis-deprotonated products, are generated. When 1 equiv. of fluoride ion is added, a complex is formed via hydrogen bonding. As a result, a slight decrease is induced in the 1H NMR signal of the triazolium CH proton (Figure II-7). With following fluoride ions added, a considerable decrease and obvious downfield shift in the 1H NMR signal of the CH proton of the triazolium ring is observed, which results from the even stronger hydrogen bonding interaction between fluoride ion and the proton of triazolium C-H bond. The results obtained from fluorescence titration experiments indicate that the hydrogen-bonding based species are not fluorescent since the initial addition of fluoride ions triggered no fluorescence response. However, as further more fluoride is added, deprotonated forms of FS are generated. Upon the addition of 4 equiv. of fluoride ions, the mono- deprotonated form of FS may be produced, which is not fluorescent. The formation of non-fluorescent mono-deprotonated FS explains why, no fluorescence response was detected (Figure II-6), but a very weak 1H NMR signal of bi-fluoride ion FHF- was recorded (Figure II-8) after the addition of up to 4 equiv. of fluoride. When more equivalents of fluoride ions are added, a neutral bis-deprotonated form of FS is produced, emitting strong fluorescence. It is necessary to be noted here that compound

29, the precursor of FS, is a highly fluorescent dye (quantum yield: 1.0). However FS, the methylation product of 29, bearing two positive charges, is non-fluorescent. This phenomenon is consistent with a well-known fact that cationic dyes have very weak fluorescence because of the greater bond length alternation character. Deprotonation 37

can effectively reduce this effect through removing the positive charge from the chromophore, resulting in fluorescence recovery. Therefore, after deprotonation of the triazolium groups, FS becomes neutral and fluorescent.

Figure II-10. Fluorescence response of test strips under irradiation at 365 nm using a hand-held UV lamp while determining fluoride ions at different concentrations in aqueous solution.

Encouraged by those promising results, filter paper based test strips of FS were prepared for facilitating F− sensing in aqueous environment. As exhibited in Figure II-10, the fluorescence emission intensity of test strips increased with the concentration of fluoride ions in aqueous solution. The concentration of fluoride ion can be detected as low as ca. 10-4 M (1.9 ppm). U.S. EPA has two standards for the fluoride concentration in drinking water. The first standard, which is enforceable, is that maximum contaminant level (MCL) for fluoride is 4.0 ppm, and the secondary non-enforceable MCL is 2.0 ppm.

Therefore, according to EPA’s standards, the test strips of FS are potential to be

38

explored to effectively determine whether the fluoride ion concentration in drinking water exceeds acceptable standards.

II.3 Conclusion

In summary, a novel highly selective fluorescence turn-on sensor was developed for fluoride anion detection. This new sensor is a combination of a fluorene platform, serving as the chromophore, and 1,2,3-triazolium groups, functioning as signaling moieties. The function of the sensor was established on the basis of deprotonation of the C-H bonds of 1,2,3-triazolium rings, which makes FS the first reported anion sensor based on the deprotonation of a C-H bond. In this work, fluoride-induced deprotonation of a C-H bond is evidenced and further applied to fluoride ion detection. FS exhibited specific fluorescence turn-on response toward fluoride anion, making it an excellent sensor for differentiating fluoride ions from other anions. Also, FS demonstrated high sensitivity for fluoride sensing. Furthermore, interactions between fluoride and the C-H bond of 1,2,3-triazolium group were examined by 1H NMR and fluorescence spectroscopy. On the basis of the results obtained from 1H NMR titration and fluorescence emission titration experiments, a reasonable explanation is suggested for the interactions between FS and fluoride anion. We anticipate that this interaction model will be explored to develop other sensing systems for selectively detecting various anions. Easy-to-prepare test strips based on FS were prepared for detecting the presence of fluoride ions in aqueous media. These test strips can be easily explored to determine fluoride anion at concentrations down to 1.9 ppm, which may provide the 39

basis inexpensively and conveniently to estimate whether the concentration of fluoride ions in drinking water is at a safe level.

II.4 Experimental

II.4.1 General

All reagents were purchased from commercial suppliers and all solvents were used as received without any further purification. All anions were used as their tetrabutylammonium salts. 2,7-Dibromo-9,9-dihexyl-9H-fluorene (25)319 and 7-bromo-

9,9-dihexyl-N,N-diphenyl-9H-fluoren-2-amine (26)320 were synthesized following the exact procedures reported in their respective literatures. 1H and 13C NMR spectroscopic measurements were carried out using a Bruker AVANCE 400 MHz spectrometer in

DMSO-d6 or CDCl3 solution with tetramethysilane (TMS) as internal reference. UV-vis absorption spectra were measured using an Agilent 8453 spectrophotometer.

Fluorescent emission spectra were recorded on a PTI QuantaMaster

Spectrofluorometer.

II.4.2 Synthesis

3,5-Di(trimethylsilylethynyl)benzyl alcohol (21). To a mixture of 3,5- dibromobenzyl alcohol (2.66 g, 10.0 mmol), CuI (0.19 g, 1.0 mmol), and Pd(PPh3)2Cl2

(0.35 g, 0.5 mmol) was added 60 mL degassed solvent mixture THF:triethylamine (4:1) followed by the dropwise addition of trimethylsilylacetylene (4.24 mL, 30.0 mmol) in an argon atmosphere. The reaction mixture was heated to reflux and stirred for 12 h. After cooling to room temperature, the solvent was removed under reduced pressure and the 40

residue was extracted with CH2Cl2/brine. The organic layer was dried over MgSO4, then filtered and dried. The crude product was further purified by flash column chromatography on silica gel using CH2Cl2 as eluent to give 21 as a yellow liquid (2.88 g,

1 96%). H NMR (400 MHz, CDCl3): δ (ppm) 7.52 – 7.48 (m, 1H), 7.41 – 7.39 (m, 2H),

4.63 (d, J = 6.0 Hz, 2H), 1.71 (t, J = 6.0 Hz, 1H), 0.24 – 0.22 (m, 18H). 13C NMR (101

MHz, CDCl3): δ (ppm) 141.31, 134.61, 130.24, 123.74, 104.04, 95.23, 64.53, 0.02.

+ HRMS (DART, m/z): calcd for C17H24OSi2 ([M+H] ) 301.1438; found 301.1428.

3,5-Diethynylbenzyl alcohol (22). A solution of 21 (2.70 g, 9.0 mmol) and KF

(2.61 g, 45.0 mmol) in 150 mL methanol was stirred at room temperature for 10 h. Then the solvent was removed under reduced pressure and the residue was extracted with

CH2Cl2/H2O. The organic layer was dried over MgSO4, filtered and concentrated in vacuo. Purification by flash column chromatography on silica gel using CH2Cl2 provided

1 22 as a yellow liquid (1.34 g, 95%). H NMR (400 MHz, CDCl3): δ (ppm) 7.54 – 7.52 (m,

1H), 7.50 – 7.45 (m, 2H), 4.67 (d, J = 6.0 Hz, 2H), 3.09 (s, 2H), 1.77 (t, J = 6.0 Hz, 1H).

13 C NMR (101 MHz, CDCl3): δ (ppm) 141.58, 134.84, 130.81, 122.86, 82.59, 78.15,

+ 64.39. HRMS (DART, m/z): calcd for C11H8O ([M+NH4] ) 174.0913; found 174.0919.

3,5-Diethynylbenzyl chloride (23). To a solution of 22 (1.25 g, 8.0 mmol) in 5 mL triethylamine and 25 mL anhydrous CH2Cl2 was added SOCl2 (0.73 mL, 10.0 mmol) dropwise under argon atmosphere at 0 °C. After stirring for 0.5 h at 0 °C, the reaction mixture was heated to reflux and stirred for 2 h. Then it was poured into ice water and extracted with CH2Cl2. The organic layer was dried over MgSO4, filtered and concentrated in vacuo. The crude mixture was purified by flash column chromatography 41

on silica gel using CH2Cl2, giving the desired compound 23 as a white solid (0.73g, yield

1 52-%). H NMR (400 MHz, CDCl3): δ (ppm) 7.56 (t, J = 1.4 Hz, 1H), 7.49 (d, J = 1.3 Hz,

13 2H), 4.52 (s, 2H), 3.11 (s, 2H). C NMR (101 MHz, CDCl3): δ (ppm) 138.21, 135.54,

+ 132.50, 123.21, 82.15, 78.60, 44.99. HRMS (DART, m/z): calcd for C11H7Cl ([M+H] )

175.0313; found 175.0315.

Diethyl 3,5-diethynylbenzylphosphonate (24). To a mixture of 23 (0.70 g, 4.0 mmol) and NaI (0.75 g, 5.0 mmol) was added 20 mL acetone, followed by the addition of triethyl phosphite (1.04 mL, 6.0 mmol). The resulting mixture was heated to 60 °C and stirred for 24 h. After cooling to room temperature, the solvent was removed under reduced pressure and the residue was extracted with ethyl acetate/H2O. The organic layer was washed three times with distilled water and then once with brine. The organic layer was dried over MgSO4, then filtered and dried. The crude product was further purified by flash column chromatography on silica gel using methanol/CH2Cl2 (1/100) as

1 eluent to give 24 as a yellow liquid (0.88 g, 80%). H NMR (400 MHz, CDCl3): δ (ppm)

7.52 – 7.49 (m, 1H), 7.44 – 7.35 (m, 2H), 4.07 – 4.00 (m, 4H), 3.13 – 3.04 (m, 4H), 1.28

13 – 1.24 (m, 6H). C NMR (101 MHz, CDCl3): δ (ppm) 134.29, 133.77, 132.75, 122.87,

82.44, 78.24, 62.44, 34.14, 32.77, 16.47. HRMS (DART, m/z): calcd for C15H17O3P

([M+H]+) 277.0988; found 277.0988.

7-(Diphenylamino)-9,9-dihexyl-9H-fluorene-2-carbaldehyde (27). To a solution of

26 (2.90 g, 5.0 mmol) in 20 mL anhydrous THF was added n-BuLi (3.0 mL of a 2.5 M solution in hexane, 7.5 mmol), within 15 min at −78 °C under argon atmosphere. The reaction mixture was stirred for 40 min before 1.0 mL of DMF was added dropwise. 42

After stirring for 1.5 h at −78 °C, the temperature was allowed to rise to 0 °C. The mixture was treated with dilute hydrochloric acid (5.0 mL, 2.0 M) at 0 °C. The organic phase was washed with water, aqueous NaHCO3, and brine. The combined organic layer was dried over MgSO4. After filtration and evaporation of the solvent, the crude product was purified by flash column chromatography on silica gel using ethyl acetate/hexanes (1/30) to give 27 as a yellow liquid (1.72 g, 65%). 1H NMR (400 MHz,

CDCl3): δ (ppm) 10.02 (s, 1H), 7.82 (dd, J = 6.3, 1.7 Hz, 2H), 7.74 – 7.69 (m, 1H), 7.61

(d, J = 8.3 Hz, 1H), 7.30 – 7.23 (m, 4H), 7.16 – 7.09 (m, 5H), 7.07 – 7.02 (m, 3H), 1.98 –

1.80 (m, J = 18.8, 4H), 1.17 – 1.00 (m, 12H), 0.79 (t, J = 7.2 Hz, 6H), 0.69 – 0.54 (m,

13 4H). C NMR (101 MHz, CDCl3): δ (ppm) 192.45, 153.85, 151.46, 149.02, 147.81,

134.66, 134.20, 130.96, 129.45, 124.54, 123.27, 123.02, 121.85, 119.28, 118.40, 55.31,

40.19, 31.64, 29.68, 23.90, 22.67, 14.15. HRMS (DART, m/z): calcd for C38H43ON

([M+H]+) 530.3414; found 530.3420.

(E)-7-(3,5-Diethynylstyryl)-9,9-dihexyl-N,N-diphenyl-9H-fluoren-2-amine (28). To a mixture of 27 (1.32 g, 2.5 mmol) and 24 (0.83 g, 3.0 mmol) in 50 mL anhydrous THF at 0 °C was added dropwise 3.5 mL of 1.0 M t-BuOK (3.5 mmol) in THF in an argon atmosphere. The reaction mixture was stirred for 30 min at 0 °C, followed by 3 h at room temperature. Then it was quenched by adding distilled water and extracted with ethyl acetate. The organic layer was washed three times with distilled water and then once with brine. The organic layer was dried over MgSO4, filtered and concentrated in vacuo. Purification by flash column chromatography on silica gel using CH2Cl2/hexanes

1 (1/7) as eluents provided 28 as a yellow solid (1.16 g, 71%). H NMR (400 MHz, CDCl3): 43

δ (ppm) 7.69 (d, J = 1.3 Hz, 2H), 7.65 – 7.58 (m, 2H), 7.55 (t, J = 1.3 Hz, 1H), 7.52 –

7.48 (m, 2H), 7.32 – 7.28 (m, 4H), 7.24 – 7.17 (m, 6H), 7.11 – 7.04 (m, 4H), 3.13 (s, 2H),

2.02 – 1.88 (m, 4H), 1.23 – 1.10 (m, 12H), 0.85 (t, J = 7.1 Hz, 6H), 0.78 – 0.74 (m, 4H).

13 C NMR (101 MHz, CDCl3): δ (ppm) 152.61, 151.35, 148.07, 147.46, 141.48, 138.30,

135.89, 134.91, 134.16, 131.45, 130.30, 129.30, 126.04, 125.46, 124.00, 123.63,

122.96, 122.69, 120.96, 120.63, 119.50, 119.34, 82.76, 78.03, 55.13, 40.42, 31.64,

+ 29.77, 23.91, 22.69, 14.18. HRMS (MALDI, m/z): calcd for C49H49N ([M+H] ) 651.3859; found 651.3853.

(E)-7-(3,5-Bis(1-phenyl-1H-1,2,3-triazol-4-yl)styryl)-9,9-dihexyl-N,N-diphenyl-9H- fluoren-2-amine (29). A mixture of degassed toluene:DMSO:H2O (4:5:1, 30 mL) was added to a mixture of 28 (0.98 g, 1.5 mmol), iodobenzene (1.22 g, 6.0 mmol), NaN3

(0.29 g, 4.5 mmol) and sodium ascorbate (59.4 mg, 0.3 mmol). Then CuI (0.11 g, 0.6 mmol) and N1,N2-dimethylethane-1,2-diamine (79.3 mg, 0.9 mmol) were added to the mixture in an argon atmosphere. The reaction mixture was stirred at room temperature and the progress of the reaction was followed by TLC. When compound 28 was completely consumed (about 2 hours), the reaction mixture was concentrated in vacuo to remove toluene and H2O. Then the residue was extracted with CH2Cl2/brine and washed with distilled water. The organic layer was dried over MgSO4, filtered and concentrated in vacuo. The crude mixture was purified by flash column chromatography on silica gel using methanol/CH2Cl2 (1/20), giving the desired compound 29 as a yellow

1 solid (1.02 g, yield 76%). H NMR (400 MHz, CDCl3): δ (ppm) 8.38 (s, 2H), 8.32 (s, 1H),

8.16 (d, J = 1.3 Hz, 2H), 7.89 – 7.81 (m, 4H), 7.63 – 7.40 (m, 11H), 7.30 – 7.24 (m, 5H), 44

7.13 (d, J = 7.3 Hz, 5H), 7.02 (t, J = 7.4 Hz, 3H), 1.98 – 1.85 (m, 4H), 1.20 – 1.04 (m,

13 12H), 0.80 (t, J = 7.1 Hz, 6H), 0.71 (s, 4H). C NMR (101 MHz, CDCl3): δ (ppm) 152.68,

151.40, 148.13, 147.39, 141.30, 139.31, 137.22, 136.08, 135.32, 131.44, 131.00,

130.01, 129.32, 129.05, 126.72, 126.00, 123.99, 123.77, 122.66, 122.09, 121.02,

120.72, 119.53, 118.23, 55.17, 40.49, 31.69, 29.83, 23.97, 22.73, 14.20. HRMS (APCI,

+ m/z): calcd for C61H59N7 ([M+H] ) 890.4906; found 890.4905.

(E)-4,4'-(5-(2-(7-(Diphenylamino)-9,9-dihexyl-9H-fluoren-2-yl)vinyl)-1,3- phenylene)bis(3-methyl-1-phenyl-1H-1,2,3-triazol-3-ium) bis(tetrafluoroborate) (FS). Dry and degassed CH2Cl2 (30 mL) was added to a mixture of 29 (0.71 g, 0.8 mmol) and trimethyloxonium tetrafluoroborate (0.30 g, 2.0 mmol) in an argon atmosphere. The resulting mixture was stirred for 3 days at room temperature under argon. The reaction mixture was quenched by adding distilled water and extracted with CH2Cl2. The solvent was removed in vacuo and the residue was dissolved into 2 mL CH2Cl2. Then 20 mL diethyl ether was added to the solution and a yellow precipitate formed. After filtration, the crude product was recrystallized from chloroform 3 times to give FS as a yellow

1 solid (0.31 g, 35%). H NMR (400 MHz, CDCl3): δ (ppm) 9.18 (s, 2H), 8.08 (d, J = 1.4

Hz, 2H), 7.98 (s, 1H), 7.86 (dd, J = 8.1, 1.7 Hz, 4H), 7.62 – 7.54 (m, 7H), 7.46 – 7.39 (m,

2H), 7.36 (d, J = 6.9 Hz, 1H), 7.30 – 7.21 (m, 5H), 7.17 – 7.13 (m, 6H), 7.06 – 6.99 (m,

3H), 4.46 (s, 6H), 2.05 – 1.84 (m, 4H), 1.19 – 1.05 (m, 12H), 0.79 (t, J = 7.0 Hz, 6H),

1 0.71 (s, 4H). H NMR (400 MHz, DMSO-d6): δ (ppm) 9.99 (s, 2H), 8.36 (d, J = 1.2 Hz,

2H), 8.12 – 8.10 (m, 5H), 7.88 – 7.75 (m, 8H), 7.69 – 7.63 (m, 3H), 7.55 (d, J = 16.0 Hz,

1H), 7.29 (t, J = 8.0 Hz, 4H), 7.12 (d, J = 2.0 Hz, 1H), 7.07 – 7.01 (m, 6H), 6.96 (dd, J = 45

8.0 Hz, 2.0 Hz, 1H), 4.59 (s, 6H), 1.93 (s, 4H), 1.10 – 1.02 (m, 12H), 0.75 (t, J = 7.2 Hz,

13 6H), 0.60 (s, 4H). C NMR (101 MHz, CDCl3): δ (ppm) 152.87, 151.81, 148.05, 147.71,

143.01, 142.02, 141.09, 135.52, 134.67, 133.99, 132.11, 130.59, 129.37, 129.22,

128.87, 126.54, 125.91, 124.15, 123.87, 123.76, 123.40, 122.87, 121.86, 121.23,

120.71, 119.44, 119.31, 55.33, 40.17, 39.66, 31.78, 29.80, 24.12, 22.74, 14.21. HRMS

+ (APCI, m/z): calcd for C63H65N7BF4 ([M-BF4] ) 1006.5342; found 1006.5336.

II.4.3 Preparation of test strips

2 A well-cut filter paper (12 × 3 mm ) was immersed into a solution of FS in CH2Cl2

(1.0 × 10-3 M) for 5 s and then dried by exposure to air. For sensing fluoride ions in water, the test strip was dipped into a fluoride-containing aqueous solution for 3 min and then dried in the air.

46

CHAPTER III: FLUORESCENCE TURN-ON SENSORS FOR K+

III.1 Introduction

Potassium, the most abundant intracellular metal cation, makes up about 0.4% of the mass of human body. Intracellular and extracellular concentrations of K+ are about

150 and 4.5 mM for mammal cells, respectively.324-325 Potassium ions play diverse roles in a number of biological processes. They are not only involved in the regulation of blood pressure and intracellular concentrations of other ions, for example, chloride and calcium ions, which are transported across the plasma membrane, but also associated with the maintenance of proper pH balance and extracellular osmolarity.326-328 Moreover, the significance of potassium ions in heartbeat regulation has been discovered.329

Potassium also plays indispensable roles in cell proliferation, muscle contraction, epithelial fluid transport, and nerve transmission.330-334

On the other hand, an unbalance in the potassium level in the human body can bring about certain human diseases such as renal disease, stroke, hypertension, seizures, and myasthenia.335-339 Furthermore, abnormal potassium fluctuations are a potential sign for the onset of several other diseases, including anorexia, bulimia, diabetes, alcoholism, heart disease, cancer, and AIDS.335-343 Hence, a delicate balance of potassium concentration is vital for human health.

However, the molecular mechanisms of potassium pathology and physiology are still inadequately examined to date. This situation is partly because of the lack of effective methods for accurately determining intracellular and extracellular potassium

47

concentration changes with good temporal and spatial fidelity. Therefore, selective and sensitive detection of potassium levels in human body fluids is of great importance, and developing an approach to achieve that is meaningful.

Continuous efforts have been devoted to extracellular and intracellular potassium detection due to the biological significance of potassium. Although various potassium sensors have been developed, none of them meet all the requirements for practical imaging applications. Common analytical methods, e.g., the potassium electrode, provide reliable results with high sensitivity.344 However, those techniques cannot be utilized for non-invasive study in biological systems. Also, they are not suitable for conducting experiments with small amount of cells, not to mention at the single cell level.

Compared with other methods, fluorescence techniques have some distinct advantages, including high sensitivity, non-invasiveness, and convenience, and thus have attracted growing attention. In 1989, Tsien et al. reported the first, and so far the best known, fluorescent potassium sensor, potassium-binding benzofuran isophthalate

(PBFI), which is currently the only commercially available potassium probe.29,345 PBFI is comprised of a benzofuran derivative, serving as the fluorophore, and a diaza-18- crown-6 ether as the recognition moiety. PBFI is capable of sensing intracellular potassium level, whereas it is not suitable for extracellular potassium sensing because of the poor sensitivity that results from its insufficient potassium binding strength.

Moreover, the selectivity of PBFI for K+ over Na+ is only modest,346 which highly limits its application in biological environments where K+ and Na+ always coexist.

48

Scheme III-1. The structure of PBFI.

Enlightened by the design of PBFI, further efforts were devoted to develop potassium probes with better properties. To increase the potassium binding strength, cryptands were synthesized and used as potassium recognition units. By coupling such a cryptand to a fluorophore, the potassium complexation of the cryptand is translated into a fluorescent signal change of the fluorophore. Masilamani et al. reported a fluorogenic potassium probe (30), which is a combination of a [222] cryptand and a coumarin fluorophore. Although the design of probe 30 successfully enhances the potassium binding strength, it still suffers from the interference from sodium. Moreover, this probe is pH-sensitive in physiological pH range, which is due to the protonation of the two aliphatic nitrogen atoms. Afterwards, Sammes et al. developed another [222] cryptand to overcome the pH interference problem.347 Instead of aliphatic nitrogens, probe 31 incorporated two aromatic nitrogens to reduce the pH sensitivity. While probe

31 is not sensitive to pH at physiological pHs, it still suffered from the sodium interference issue. In addition, probe 31 showed relatively small fluorescence signal change upon binding potassium ions.

49

Scheme III-2. Structures of compounds 30 and 31.

On the basis of the advantages and disadvantages of the foregoing potassium probes, He et al. developed a [2.2.3]-triazacryptand (TAC) as a potassium recognition unit and connected it to an amino-naphthalimide fluorophore to produce probe 32.33 As a potassium sensor, 32 has some desirable properties: (1) high selectivity against sodium and other biological cations; (2) strong potassium binding strength; (3) large fluorescence signal change upon binding potassium ions; (4) no pH interference within physiological pH range. These advantages render it a better potassium sensor than the former ones and a good candidate for sensing extracellular potassium concentration changes in blood and serum.

Scheme III-3. Structures of TAC and compound 32.

50

Attracted by the excellent performance of TAC in recognizing potassium ions,

Verkman et al. and Tian et al. subsequently developed several fluorescent potassium sensors based on different fluorophores, using TAC as the potassium-complexing moiety.36-37,39-40 All of these TAC-based potassium probes exhibit high K+/Na+ selectivity and no pH interference. Probe 33, a conjugate of TAC and xanthylium, was the first fluorescence turn-on potassium sensor reported by Verkman.36 In the presence of 0-50 mM K+, the fluorescence intensity of 33 (7 μM) increased up to 14-fold. Probe 33 was explored to monitor K+ waves in the brain cortex. However, its easy uptake by many cell types seriously limits its extracellular application. Tian et al. synthesized probe 34, which is a combination of TAC and a strong electron-withdrawing group, 2- dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran.40 Probe 34 was capable of sensing K+ up to 1600 mM. In the presence of K+ with concentrations of 140 and 1400 mM, the fluorescence intensity of 34 was increased by 4- and 50-fold, respectively. The ability of sensing K+ over such a broad concentration range makes it the first fluorescent

K+ sensor that is suitable for detecting highly concentrated K+ and selectively sensing intracellular K+ level. Confocal fluorescence microscopy experiments demonstrated that probe 34 could be utilized for detecting K+ within living cells.

51

Scheme III-4. Structures of compounds 33 and 34.

All of the reported TAC-based potassium probes demonstrate that the TAC platform is the most desirable potassium recognition unit so far. However, there is a serious drawback of TAC. It is difficult to be reproduced because of its complicated multistep synthesis and low overall yield. Consequently, widespread application is limited. After carefully examining its synthetic route, we found that the synthesis of TAC is possible to be optimized. Hence, our first goal was to improve the synthesis of TAC, shortening its synthetic route and enhancing the overall yield. After that, TAC-based fluorescent potassium sensors were synthesized, characterized, and examined in solution and then cellular environment. Moreover, since there is no two-photon absorbing fluorescent potassium sensors reported so far (the merits of two-photon excitation microscopy are illustrated in section I.1), efforts were devoted to develop a new potassium sensor that can be excited by two-photon absorption.

52

III.2 Results and Discussion

The synthetic route of TAC reported by He et al. is shown in Scheme III-5. In the original synthetic route, compound 36 was synthesized in 2 steps with 2-nitrophenol as the starting material. Since compound 36 is commercially available, the work herein will not include its synthesis. In the reported synthesis, TAC was obtained in 7 steps with a

3.6% overall yield, starting from 5-methyl-2-nitrophenol, which was first reacted with 1,2- dibromoethane in DMF at 120 °C in the presence of K2CO3 to produce compound 35.

Then 2 equiv. of 35 and 1 equiv. of compound 36 were refluxed in acetonitrile with KI as catalyst and K2CO3 as base to form compound 37. The nitro groups of compound 37 were reduced to amino groups by 2.2 atm hydrogen gas in DMF, using 5% Pd/C as the catalyst, affording compound 38. Subsequently, a 21-membered macrocycle compound

39 was produced through the reaction between compound 38 and DODC, which was obtained from reaction of 3,6-dioxaoctanedioic acid with oxalyl chloride, in CH2Cl2 with

TEA as the base. In this reaction, two amide groups were synchronically formed, generating the 21-membered macrocycle. The newly formed amides were then reduced to amines by BH3/THF, producing compound 40. Compound 41 was prepared through the same reaction that provided compound 39, with compound 40 instead of 38 reacting with DODC in CH2Cl2 and TEA. Another 21-membered macrocycle was formed in compound 41 with two amide groups that were also further reduced to amino groups by

BH3/THF to produce the desired product TAC.

53

Scheme III-5. Reported synthetic route of TAC.a

a Reagents and conditions: (a) BrCH2CH2Br, K2CO3, DMF, 120 °C, 50%; (b) K2CO3, KI, CH3CN, reflux, 3 d, 55%; (c) H2, 5% Pd/C, DMF, 97%; (d) DODC, TEA, CH2Cl2, 69%; (e) BH3/THF, 61%; (f) DODC, pyridine, CH2Cl2, 51%; (g) BH3/THF, 63%.

After examining the procedures of each of the above steps, some modifications and optimizations were made to the synthesis of TAC. The improved synthetic route of

TAC is shown in Scheme III-6. For the first step, the reaction temperature is the key point. By increasing the reaction temperature from the reported 120 °C to reflux in DMF, the yield of the reaction was increased from 50% to 81%. Considering the possibility that the starting material 5-methyl-2-nitrophenol may be oxidized by oxygen at high temperature, the reaction was performed under argon atmosphere. For the second step, 54

the literature procedure involved refluxing a mixture of 35 and 36 in acetonitrile in the presence of KI and K2CO3. Unfortunately, this approach is very inefficient. After refluxing for 16 h, mono-substituted aniline was produced as the major product and only trace desired product (bis-substituted aniline) was formed. Repeatedly adding compound 35 every 20 h 3 times resulted in a modest yield (around 50%) of compound

37. To achieve better reaction conditions, DMF was employed as the reaction medium rather than MeCN, and the reaction temperature was increased to 120 °C, but similar results were obtained.

Finally, a totally different reaction system was adopted to perform this reaction, using a mixture of 1,4-dioxane and water (2:3) as the reaction medium and CaCO3 as base. As a result, the desired compound 37 was provided in a much higher yield (91%).

For the step of reducing nitro groups of 37 to amino groups, hydrogen gas was used as the reductive reagent and compound 38 was obtained in a 97% yield. Our goal was also to find a more convenient approach, avoiding utilizing the volatile hydrogen gas. To achieve this goal, hydrazine monohydrate was employed as the reducing reagent. An equivalent yield (97%) of the product resulted when the reaction was catalyzed by Pd/C.

Furthermore, an equally efficient and more economic catalyst FeCl3/C (a mixture of

FeCl3 and activated carbon) also provided compound 38 in a good yield (96%).

55

Scheme III-6. Optimized synthetic route of TAC.a

a Reagents and conditions: (a) BrCH2CH2Br, K2CO3, DMF, reflux, 2 h; (b) KI, CaCO3, water:dioxane (3:2), reflux, 36 h; (c) H2NNH2·H2O, activated carbon, FeCl3·6H2O, THF:MeOH (1:1), reflux, 20 h; (d) 1,2-bis(2- iodoethoxy)ethane, K2CO3, MeCN, reflux, 4 d; (e) 1,2-bis(2-iodoethoxy)ethane, CaCO3, water:dioxane (1:2), reflux, 4 d.

Macrocyclization reactions are extraordinarily important in the synthesis of TAC.

In the reported synthetic route, both of the macrocyclization reactions were achieved by means of amide synthesis (steps d and f in Scheme III-5). Following each of these two steps, there was a reduction reaction, reducing the newly formed amides (compounds

39 and 41 in Scheme III-5) to amines (compound 40 and TAC), respectively. Here we attempted to synthesize compound 40 directly from compound 38 and TAC directly from

40, as displayed in Scheme III-6, skipping the synthesis of compounds 39 and 41.

Enlightened by the results obtained from synthesizing compound 37 in which the

K2CO3/MeCN system worked well in producing mono-substituted anilines but poorly in forming bis-substituted anilines, these conditions were employed to prepare compound

40. In order to find an efficient way to synthesize 40, different conditions were screened,

56

including reactants, solvents, bases, and reaction temperatures. As shown in Table III-1, the K2CO3/MeCN system (entry 1) turned out to be the most efficient one among those examined. Compound 40 was realized through the reaction between 38 and 1,2-bis(2- iodoethoxy)ethane with K2CO3 as the base in MeCN under reflux. Although the yield

(40%) of this reaction was not very high, it shortened the synthetic route of TAC and the yield was nearly equal to the overall yield (42%) of steps d (69%) and e (61%) in

Scheme III-5. Therefore, to some extent, this new synthetic approach is more efficient.

The direct synthesis of TAC from 40 adopted the same approach that was applied to preparing 37 since it proved to be a good method for synthesizing bis- substituted anilines. By refluxing a mixture of 40, 1,2-bis(2-iodoethoxy)ethane, and

CaCO3 in 1,4-dioxane/water (2:1), TAC was produced in a good yield (69%), which is much higher than the combined overall yield (32%) of steps f (51%) and g (63%) in

Scheme III-5.

57

Table III-1. Optimization of reaction conditions for the synthesis of 40.a

entry A/B Base solvent T yield (%)

b c d 1 A K2CO3 MeCN reflux 63 , 47 , 40

b c d 2 B K2CO3 MeCN reflux 50 , 40 , 31

3 A TEA MeCN reflux 14c

4 B TEA MeCN reflux 8c

5 A TEA toluene reflux 35b, 29c

6 B TEA toluene reflux 31b, 26c

c 7 A K2CO3 DMF 120 °C 9

c 8 B K2CO3 DMF 120 °C 4 aReaction conditions: 38 (1.0 mmol), A/B (1.1 equiv.), base (3.0 equiv.), solvent (100 mL), 4 d, Ar. bDetermined by 1H NMR analysis. cDetermined by LC-MS analysis. dIsolated yield.

III.2.1Potassium sensor 1 (KS1)

Having improved the synthesis of TAC, TAC-CHO was obtained following a literature procedure (Scheme III-7).33 KS1 was then synthesized for K+ sensing in 10% yield through a condensation reaction of TAC-CHO with 2,4-dimethylpyrrole in CH2Cl2 in the presence of a catalytic amount of TFA at room temperature, followed by an

58

oxidation reaction with DDQ (2,3-dichloro-5,6-dicyano-1,4-benzoquinone) and a subsequent reaction with BF3·OEt2 in the presence of TEA at room temperature.

Scheme III-7. Synthetic route for KS1.a

a Reagents and conditions: (a) DMF, POCl3, 0 °C to room temperature, overnight; then 70 °C, 1 h; (b) 2,4- dimethylpyrrole, TFA, CH2Cl2, room temperature, overnight; then DDQ, 4 h; then TEA, BF3·OEt2, overnight.

The fluorescence response of KS1 to K+ ion was investigated in 5 mM HEPES buffer (pH 7.2)/MeCN (4:1, v/v). Figure III-1 shows the fluorescence emission spectra of

KS1 in the presence of various biologically-significant metal cations at their physiological concentrations. As expected, KS1 exhibited very high selectivity for K+ over other metal cations. In the absence of cations, the free KS1 emitted a very weak fluorescence at 512 nm. Upon the addition of K+ ions, the fluorescence intensity was dramatically increased, whereas the addition of any other metal cations induced little to no changes in the fluorescence intensity or spectrum of KS1.

59

Figure III-1. Fluorescence emission spectra of KS1 (10 μM) in 5 mM HEPES buffer (pH 7.2)/MeCN (4:1, v/v) upon addition of various biological metal cations at their physiological concentrations: Li+ (1.0 mM), Na+ (150 mM), K+ (150 mM), Mg2+ (2.0 mM), Ca2+ (2.0 mM), Zn2+ (50 μM), Cu2+ (50 μM), Fe3+ (50 μM), Co2+ (50 μM), Ni2+ (50 μM). λex = 480 nm.

To further examine the efficiency of KS1 towards sensing K+ ions, fluorescence emission titration experiments were carried out in 5 mM HEPES buffer (pH 7.2)/MeCN

(4:1, v/v). Solutions were balanced with NaCl to maintain a constant ionic strength of

150 mM. As demonstrated in Figure III-2, gradual enhancement of the fluorescence intensity of KS1 was observed upon progressive addition of K+ ions. The fluorescence intensity was increased by 14-fold in the presence of 150 mM K+. Higher concentrations of K+ ions were not able to further increase the fluorescence intensity of KS1. Moreover,

KS1 was capable of detecting 1 mM K+ with co-existence of a high concentration of Na+.

Since the extracellular and intracellular concentrations of potassium are ca. 4.5 mM and 60

150 mM,324,348 respectively, KS1 is potentially suitable for determining physiological K+ levels.

Figure III-2. Enhancements in fluorescence emission spectra of KS1 (10 μM) in 5 mM HEPES buffer (pH 7.2)/MeCN (4:1, v/v) upon continuous addition of 150 mM K+ ions. Ionic strength was maintained at 150 mM by addition of NaCl. λex = 480 nm.

Moreover, the pH sensitivity of KS1 was determined in H2O/MeCN (4:1, v/v) solutions with various pH values between 3.0 and 8.0. As shown in Figure III-3, no obvious changes of the fluorescence emission spectra of KS1 were observed in the pH range of 6.2-8.0. When the pH was reduced to 6.0, a small enhancement in the fluorescence intensity of KS1 was recorded. Further lower pH values induced stronger fluorescence emission until the pH of the solution reached 3.0. Significantly, these results indicate that KS1 is insensitive to pH in the physiological pH range (6.8-7.4).

61

Figure III-3. Fluorescence emission spectra of KS1 (10 μM) in H2O/MeCN (4:1, v/v) at different pH. λex = 480 nm.

Encouraged by the above results, KS1 was explored to detect the change of intracellular potassium. Figure III-4 shows images of cells taken at different time points

(0, 30, 60, 90, 120 min) and the average fluorescence emission intensity of each image is shown in Figure III-5. U87MG cells were incubated with a 5 µM solution of KS1 in complete MEM medium for 10 min. As expected, cells were highly fluorescent as shown in images III-4A and III-4F, which is consistent with intracellular K+ levels high enough to trigger strong fluorescence of KS1.

It has been shown that the combination of nigericin, ouabain octahydrate, and bumetanide can effectively bring about K+ efflux of cells.40,349 To examine the ability of

KS1 to respond to levels of K+ changes in living cells, a mixture of a solution of nigericin (5 µM), ouabain octahydrate (10 µM), and bumetanide (10 µM) in complete 62

MEM medium was pumped into cell chambers and images of living cells were taken at different times. With the K+ depletion induced by nigericin, ouabain octahydrate, and bumetanide, the fluorescence intensity from cells gradually decreased to a very weak state (from image III-4F to III-4J). For the control experiment, after the same time, cells remained highly fluorescent (images III-4B to III-4E), exhibiting little visible change compared to their original state (image III-4A). These results indicate that KS1 is promising to be utilized to monitor intracellular K+ levels of living cells.

Figure III-4. Images of live U87MG cells in MEM medium (A-E), and in an MEM medium solution of nigericin (5 µM), ouabain octahydrate (10 µM), and bumetanide (10 µM) (F-J), at 0 min (A, F), 30 min (B, G), 60 min (C, H), 90 min (D, I), and 120 min (E, J) after incubation with KS1 (5 µM).

63

Figure III-5. Average fluorescence intensity of cell images as a function of time. (A) control experiment (Images III-4A to III-4E); and (B) cells treated with nigericin, ouabain octahydrate, and bumetanide (Images III-4F to III-4J).

III.2.2 Potassium sensor 2 (KS2)

After verifying the effectiveness of the TAC group as a K+ recognition unit and obtaining desirable properties of KS1 as a promising K+ sensor for sensing intracellular potassium, a hydrophilic TAC-based fluorescent sensor was designed and synthesized for K+ sensing. This new potassium sensor (KS2) was also established on a BODIPY platform, but its design strategy is different from that of KS1. First, two long polyethylene glycol chains (PEG) were introduced to the BODIPY core to increase the water solubility of the dye. Second, the TAC group was conjugated to the BODIPY core via a double bond to extend the conjugation extent of the dye and increase its two-

64

photon absorption (2PA) cross section to make it a two-photon excitable fluorescent potassium sensor.

The synthetic route for KS2 is shown in Scheme III-8. The synthesis of KS2 began with PEG 550, which was used to prepare compound 42 according to a literature procedure.350 Compound 42 was then treated with 2,4-dihydroxybenzaldehyde in the presence of potassium carbonate at 130 °C, producing compound 43 in DMF.

Compound 44 was synthesized via a condensation of 43 with 2,4-dimethylpyrrole in

CH2Cl2 in the presence of a catalytic amount of TFA at room temperature, followed by an oxidation reaction with DDQ and subsequent chelation reaction with BF3·OEt2 in the presence of TEA at room temperature. Iodination of 44 with NIS (N-iodosuccinimide) in the dark at room temperature in CH2Cl2 afforded 45 as red liquid. A Sonogashira coupling reaction was performed between 45 and phenylacetylene with Pd(PPh3)4 and

CuI as catalysts at 45 °C in THF:TEA (4:1 v/v), affording 46 as a purple liquid. The target product (KS2) was obtained through a Knoevenagel condensation reaction between compound 46 and TAC-CHO in the presence of piperidine and glacial acetic acid in n-butanol:toluene (1:1 v/v).

65

Scheme III-8. Synthetic route for KS2.a

a Reagents and conditions: (a) TsCl, NaOH, THF, H2O, 0 °C ; (b) K2CO3, DMF, 130 °C, overnight; (c) 2,4- dimethylpyrrole, TFA, CH2Cl2, room temperature, overnight; then DDQ, 4 h; then TEA, BF3·OEt2, overnight; (d) NIS, CH2Cl2, in the dark, room temperature, 5 h; (e) phenylacetylene, CuI, Pd(PPh3)4, THF:TEA (4:1), in the dark, 45 °C, 16 h; (f) TAC-CHO, piperidine, glacial acetic acid, n-butanol:toluene (1:1), reflux, overnight.

66

The K+ sensing ability of KS2 was examined in 5 mM HEPES buffer (pH

7.2)/MeCN (3:1, v/v). The fluorescence emission spectra of KS2, in the presence of various biological metal cations at their physiological concentrations, are shown in

Figure III-6. The free KS2 emitted almost no fluorescence in the absence of cations.

Upon the addition of K+, a striking red fluorescence with a maximum emission wavelength at 644 nm was immediately observed. However, the addition of other metal cations brought about no considerable change in the fluorescence spectra of KS2.

Therefore, similar to KS1, KS2 presented very high selectivity for K+ ion over other biologically-relevant cations.

Figure III-6. Fluorescence emission spectra of KS2 (10 μM) in 5 mM HEPES buffer (pH 7.2)/MeCN (3:1, v/v) upon addition of various biologically-important metal cations at their physiological concentrations: Li+ (1.0 mM), Na+ (150 mM), K+ (150 mM), Mg2+ (2.0 mM), Ca2+ (2.0 mM), Zn2+ (50 μM), Cu2+ (50 μM), Fe3+ (50 μM), Co2+ (50 μM), Ni2+ (50 μM). λex = 600 nm.

67

K+ titration experiments were carried out to investigate the efficiency of KS2 towards K+ sensing in 5 mM HEPES buffer (pH 7.2)/MeCN (3:1, v/v) solutions. To maintain a constant ionic strength of 150 mM, sample solutions were balanced with

NaCl. UV-vis absorption spectroscopy was first used to conduct titration experiments.

As displayed in Figure III-7, the solution of KS2 without adding K+ ions exhibited an absorption peak at 633 nm. Upon the progressive addition of K+ ions, the absorption maximum wavelength of KS2 gradually blue-shifted to 617 nm. At the same time, the absorption intensity of the sample was moderately increased. The behavior of KS2 in absorption titration experiments was different from that of KS1, which demonstrated no change in the absorption spectra upon the addition of K+ ions.

Figure III-7. Absorption spectra of KS2 (10 μM) in 5 mM HEPES buffer (pH 7.2)/MeCN (3:1, v/v) upon progressive addition of K+.

68

To further examine the K+ sensing ability of KS2, fluorescence emission titration experiments were performed in 5 mM HEPES buffer (pH 7.2)/MeCN (3:1, v/v). Solutions were balanced with NaCl to maintain a constant ionic strength. Figure III-8 shows the fluorescence emission spectra of KS2 in the absence and presence of different concentrations of K+ ions. With increased concentration of K+, the fluorescence emission intensity was enhanced accordingly until the concentration of K+ reached 20 mM. In the presence of 20 mM K+, the fluorescence intensity of KS2 was increased by

29-fold, further addition of K+ ions resulted in no additional change in the fluorescence spectra of KS2. In addition, KS2 was capable of detecting 0.1 mM K+ with co-existence of a high concentration of Na+.

Figure III-8. Fluorescence emission spectra of KS2 (10 μM) in 5 mM HEPES buffer (pH + 7.2)/MeCN (3:1, v/v) upon progressive addition of K . λex = 600 nm.

69

Also, the pH sensitivity of KS2 was investigated at various pH between 3.0 and

8.0 in H2O/MeCN (3:1, v/v) solutions. Figure III-9 shows the fluorescence emission spectra of KS2 at pH 3.0, 4.0, 5.0, 5.8, 6.0, 6.5, 7.0, and 8.0. In the solutions of KS2 with pH values between 6.0 and 8.0, no considerable fluorescence emission signal was detected. However, when the pH of a sample was lower than 6.0, a characteristic fluorescence signal of KS2 was recorded. As the pH decreased, the fluorescence emission intensity of KS2 became stronger until the pH of the solution reached 3.0.

These results suggest that KS2, similar to KS1, is not sensitive to pH in physiological ranges.

Figure III-9. Fluorescence emission spectra of KS2 (10 μM) in H2O/MeCN (3:1, v/v) as a function of pH. λex = 600 nm.

70

Moreover, 2PA experiments were carried out to determine the 2PA cross section of KS2. The open-aperture Z-scan method351 was used for direct 2PA cross section measurements over a broad spectral region, 940-1260 nm, with a single laser beam as the irradiation light source. Figure III-10 shows the one-photon and two-photon absorption spectra of KS2 in DCM. The maximum absorption wavelength in the 1PA spectrum is 637 nm. For 2PA, KS2 exhibited a maximum 2PA cross section (δ2PA) of ≈

500 GM [1 GM (Göpper Meyer) = 10-50 cm4∙ s∙ photon-1] at 940 nm. Compared to the data of reported for 2PA fluorescent probes for other metal cations (no 2PA fluorescent probe for K+ has been reported so far), the high 2PA cross section, long NIR absorption wavelength, and red-emitting fluorescence of KS2 make it an excellent prospective 2PA fluorescent K+ sensor.

Figure III-10. One-photon absorption (red) and 2PA (green circles) spectra of KS2.

71

III.3 Conclusion

In summary, the synthesis of TAC was successfully optimized. The synthetic route was shortened, and the overall yield was enhanced from 3.6% to 19.5%. Two BODIPY- based fluorescent K+-selective sensors, KS1 and KS2, were synthesized and characterized. Both exhibited excellent selectivity toward K+ ion over other physiological metal cations and high sensitivity for K+ sensing. In comparison to KS2, KS1 was able to determine K+ at higher concentration. In contrast to that of KS1, the absorption profile of KS2 can also be affected by the addition of K+ ions. Moreover, both dyes were pH insensitive in the physiological pH range. KS1 and KS2 were investigated to cell imaging. Confocal microscopy experiments demonstrated that they were both capable of sensing K+ within living cells. Furthermore, 2PA determination revealed that KS2 possessed a desirable 2PA cross section of 500 GM at 940 nm. Therefore, KS2 is a promising two-photon red-emitting fluorescent sensor for K+ ions.

III.4 Experimental

III.4.1 General

All reagents and solvents were purchased from commercial suppliers and used without further purification. 1H and 13C NMR spectra were carried out on a Bruker

AVANCE spectrometer (400 MHz). LC-MS analysis was recorded on an Agilent 1260

Infinity – 6230 TOF LC/MS. HR-MS analyses were performed at the Department of

Chemistry, University of Florida. Flash column chromatography was performed on a

72

CombiFlash® Rf+ automated flash chromatography using RediSep Rf Gold® normal- phase HP silica columns. UV-vis absorption spectra were recorded on an Agilent 8453 spectrophotometer. Fluorescence emission spectra were measured using an FLS980 fluorescence spectrometer. Fluorescence microscopy images were recorded on an

Olympus IX-81 DSU microscope equipped with a Hamamatsu EM-CCD C9100 digital camera using a FITC filter cube (Ex: 477/50; DM: 507; Em: 536/40) and a 20x (Olympus

LUCplanFLN 20x, N.A. = 0.45) objective lens. Two-photon absorption measurements were performed using a Coherent Legend Elite system (amplified Ti:Sapphire system) and an optical parametric generator/amplifier (Coherent OPerA Solo), providing laser pulses of 100 fs (FWHM) duration with 1 kHz repetition rate. A single laser beam from the first OPA was used for direct 2PA cross section measurements by the open- aperture Z-scan method. The 2PA measurements were performed in 1 mm spectrofluorometric quartz cuvette with concentration of 3×10-3 M ≤ C ≤ 4×10-3 M at room temperature.

III.4.2 Synthesis

Synthesis of compound 35. To a mixture of 5-methyl-2-nitrophenol (7.66 g, 50 mmol), 1,2-dibromoethane (47.0 g, 250 mmol), K2CO3 (13.8 g, 100 mmol) was added

50 mL degased anhydrous DMF under argon atmosphere. The reaction mixture was heated to reflux and stirred for 2 h. After cooling to room temperature, the solvent was removed under reduced pressure. Then the residue was added 100 mL CH2Cl2 and filtered. The filtrate was washed with 1N NaOH (100 mL × 3) and brine (100 mL × 2).

The organic layer was dried over MgSO4, then filtered and condensed to give a brown 73

liquid, which crystalized after cooling to room temperature to provide 35 as a yellow solid (10.5 g, 81%). The NMR data are in accord with the literature values.33

Synthesis of compound 37. A mixture of CaCO3 (2.0 g, 20 mmol) and KI (3.32 g,

20 mmol) in 30 mL distilled water was heated to reflux under argon atmosphere. Then a solution of 35 (7.80 g, 30 mmol) and 36 (1.67 g, 10 mmol) in 20 mL degased 1,4- dioxane was added. The resulting reaction mixture was stirred under reflux for 16 h.

More 35 (2.60 g, 10 mmol) was added and the reaction mixture was refluxed for another

20 h. After cooling to room temperature, the mixture was filtered and the filtrate was condensed to 20 mL. Then the filtrate was extracted with CH2Cl2 (20 mL × 3). The organic layer was dried over MgSO4, filtered and concentrated in vacuo. Purification by flash column chromatography using CH2Cl2 provided 37 as yellow solid (4.76 g, 91%).

The NMR data are in accord with the literature values.33

Synthesis of compound 38. To a solution of 37 (4.73 g, 9.0 mmol) in 25 mL anhydrous THF was added activated carbon (0.27 g) and a pre-dissolved 25 mL methanol solution of FeCl3·6H2O (0.49 g, 1.8 mmol) under argon atmosphere. The resulting reaction mixture was heated to reflux and then hydrazine monohydrate (9.0 g,

180 mmol) was added dropwise. After refluxing for 20 h, the reaction mixture was cooled to room temperature and filtered. The residue was washed with 10 mL THF and the combined filtrate was condensed. Then the crude mixture was dissolved into 50 mL

CH2Cl2 and washed with brine (50 mL × 2). The organic layer was dried over MgSO4, filtered and condensed to give 38 as a light yellow liquid (4.03 g, yield 96%). The NMR data were in accord with the literature values.33 74

Synthesis of compound 40. A mixture of K2CO3 (0.42 g, 3.0 mmol) and 50 mL degased acetonitrile was heated to reflux under argon atmosphere. Then a solution of

38 (0.47 g, 1.0 mmol) and 1,2-bis(2-iodoethoxy)ethane (0.41 g, 1.1 mmol) in 50 mL degased acetonitrile was added dropwise over 4 h. The resulting reaction mixture was stirred under reflux and the reaction progress was monitored by LC-MS. After four days, the LC-MS results indicated that the reaction was complete. After cooling to room temperature, the solvent was removed under reduced pressure and the residue was extracted with CH2Cl2/H2O and washed three times with brine. The organic layer was dried over MgSO4, then filtered and condensed. The crude product was further purified by flash column chromatography using 2.5% methanol/CH2Cl2 as eluent to give 40 as an off-white solid (0.23 g, 40%). The NMR data are in accord with the literature values.33

Synthesis of TAC. A mixture of CaCO3 (0.30 g, 3.0 mmol) and 50 mL distilled water was heated to reflux under argon atmosphere followed by the addition of 50 mL degased 1,4-dioxane. Then a solution of 40 (0.58 g, 1.0 mmol) and 1,2-bis(2-iodoethoxy) ethane (0.37 g, 1.0 mmol) in 50 mL degased 1,4-dioxane was added dropwise over 4 h.

The resulting reaction mixture was stirred under reflux and the reaction progress was monitored by LC-MS. 4 days later, the LC-MS results indicated that the reaction completed. After cooling to room temperature, the mixture was filtered and the filtrate was condensed to 50 mL. Then the filtrate was extracted with CH2Cl2 (50 mL × 3). The organic layer was dried over MgSO4, filtered and concentrated in vacuo. Purification by flash column chromatography using 3.0% methanol/CH2Cl2 provided TAC as a colorless foamy solid (0.48 g, 69%). The NMR data are in accord with the literature values.33 75

Synthesis of KS1. To a solution of TAC-CHO (0.36 g, 0.5 mmol) and 2,4- dimethylpyrrole (0.11 g, 1.1 mmol) in CH2Cl2 (50 mL) was added 2 drops of trifluoroacetic acid. The mixture was stirred at room temperature overnight, then a mixture of 2,3-dichloro-5,6-dicyano-p-benzoquinone (0.14 g, 0.6 mmol) in CH2Cl2 (10 mL) was added. The reaction mixture was stirred continuously for another 4 h. After the addition of 3 mL triethylamine, 3 mL BF3·OEt2 was added dropwise to the mixture. The mixture was kept stirring at room temperature overnight, then filtered through a celite pad. The residue was washed with 20 mL CH2Cl2 and the combined filtrate was rotary evaporated to dryness. The residue was dissolved in 30 mL CH2Cl2 and the solution was washed with 30 mL 5% aqueous NaHCO3 solution followed with water (30 mL × 2).

The organic layer was dried over anhydrous MgSO4, filtered and then evaporated in vacuo. The crude product was purified by flash column chromatography using 2.0%

1 methanol/CH2Cl2 as the eluent to give the desired KS1 as a red solid (0.048 g, 10%). H

NMR (400 MHz, CDCl3): δ (ppm) 7.25 (d, J = 8.0 Hz, 1H), 6.87 (d, J = 7.7 Hz, 2H), 6.78

(d, J = 1.7 Hz, 1H), 6.74 (dd, J = 8.0, 1.7 Hz, 1H), 6.66 (d, J = 7.7 Hz, 2H), 6.54 (s, 2H),

5.97 (s, 2H), 4.15 – 3.28 (m, 39H), 2.54 (s, 6H), 2.24 (s, 6H), 1.45 (s, 6H). 13C NMR

(101 MHz, CDCl3): δ (ppm) 155.39, 153.28, 152.56, 143.11, 141.88, 139.08, 138.33,

132.63, 131.75, 128.32, 121.97, 121.54, 121.38, 121.20, 113.94, 113.52, 71.37, 71.23,

70.17, 68.28, 66.96, 59.25, 53.98, 52.97, 21.21, 14.70, 14.45. HRMS (MALDI-TOF, m/z):

+ calcd for C52H68N5O8BF2 ([M+H] ) 940.5210; found 940.5233.

Synthesis of compound 42. Sodium hydroxide (7.8 g, 196.0 mmol) in 40 mL water and PEG 550 (38.0 g, 70.0 mmol) in 40 mL THF were mixed and cooled in an ice- 76

water bath with stirring and p-toluenesulfonyl chloride (24.0 g, 126.0 mmol) in 40 mL

THF was added dropwise over 2 h. The reaction mixture was stirred for an additional 2 h at 5 °C, poured into 100 mL ice-water and extracted with CH2Cl2 (50 mL × 2). The combined organic extracts were washed with water (50 mL × 2) and brine (50 mL × 2), dried over MgSO4 and the solvent was removed in vacuo to yield 42 as a colorless

1 liquid (40.7 g, 99%). H NMR (400 MHz, CDCl3): δ (ppm) 7.78 (d, J = 8.6 Hz, 2H), 7.33

(d, J = 8.6 Hz, 2H), 4.17 – 4.11 (m, 2H), 3.69 – 3.50 (m, 48H), 3.36 (s, 3H), 2.43 (s, 3H).

13 C NMR (101 MHz, CDCl3): δ (ppm) 144.87, 133.13, 129.92, 128.08, 72.03, 70.84,

70.70, 70.67, 70.61, 69.34, 68.77, 59.13, 21.74.

Synthesis of compound 43. To a mixture of 42 (17.6 g, 25 mmol), 2,4- dihydroxybenzaldehyde (1.38 g, 10 mmol), K2CO3 (3.04 g, 22 mmol) was added 50 mL degased anhydrous DMF under argon atmosphere. The reaction mixture was heated to

130 °C and stirred overnight. After cooling to room temperature, the solvent was removed under reduced pressure. Then the residue was added 100 mL CH2Cl2 and filtered. The filtrate was washed with brine (100 mL × 2). The organic layer was dried over MgSO4, then filtered and condensed under vacuum. The crude product was further purified by flash column chromatography using 3.0% methanol/CH2Cl2 as eluent to give

1 compound 43 as a colorless liquid (10.7 g, 89%). H NMR (400 MHz, CDCl3): δ (ppm)

10.32 (s, 1H), 7.79 (d, J = 8.7 Hz, 1H), 6.55 (dd, J = 8.7, 2.2 Hz, 1H), 6.48 (d, J = 2.2 Hz,

1H), 4.18 (dd, J = 9.8, 5.8 Hz, 4H), 3.91 – 3.84 (m, 4H), 3.76 – 3.57 (m, 87H), 3.54 (dd,

13 J = 6.1, 3.3 Hz, 4H), 3.37 (s, 6H). C NMR (101 MHz, CDCl3): δ (ppm) 188.26, 165.28,

77

162.92, 130.22, 119.30, 106.68, 99.55, 72.54, 71.94, 71.00, 70.87, 70.63, 70.61, 70.58,

70.52, 70.36, 69.46, 69.43, 68.25, 67.79, 61.72, 59.04.

Synthesis of compound 44. To a solution of 43 (6.01 g, 5.0 mmol) and 2,4- dimethylpyrrole (1.05 g, 11.0 mmol) in 500 mL CH2Cl2 was added 5 drops of trifluoroacetic acid. The mixture was stirred at room temperature overnight, then a mixture of 2,3-dichloro-5,6-dicyano-p-benzoquinone (1.36 g, 6.0 mmol) in 100 mL

CH2Cl2 was added. The reaction mixture was stirred continuously for another 4 h. After the addition of 30 mL triethylamine, 30 mL BF3·OEt2 was added dropwise to the mixture.

The mixture was kept stirring at room temperature overnight, then filtered through a celite pad. The residue was washed with 200 mL CH2Cl2 and the combined filtrate was rotary evaporated to dryness. The residue was dissolved in 300 mL CH2Cl2 and the solution was washed with 300 mL 5% aqueous NaHCO3 solution followed with water

(300 mL × 2). The organic layer was dried over anhydrous MgSO4, filtered and then evaporated in vacuo. The crude product was purified by flash column chromatography using 2.5% methanol/CH2Cl2 as the eluent to give 44 as a dark red liquid (1.53 g, 22%).

1 H NMR (400 MHz, CDCl3): δ (ppm) 6.98 (d, J = 8.2 Hz, 1H), 6.62 – 6.52 (m, 2H), 5.93

(s, 2H), 4.17 – 4.12 (m, 2H), 4.05 – 4.01 (m, 2H), 3.89 – 3.86 (m, 2H), 3.75 – 3.50 (m,

13 125H), 3.42 – 3.34 (m, 10H), 2.51 (s, 6H), 1.47 (s, 6H). C NMR (101 MHz, CDCl3): δ

(ppm) 161.09, 156.72, 154.74, 142.85, 139.12, 132.12, 130.00, 120.78, 116.66, 106.32,

100.49, 72.46, 72.00, 71.06, 70.94, 70.59, 70.55, 70.43, 70.28, 69.80, 69.15, 69.09,

67.67, 61.65, 59.12, 14.64, 14.17.

78

Synthesis of compound 45. To a solution of compound 44 (1.42 g, 1.0 mmol) in

10 mL anhydrous CH2Cl2 was added N-iodosuccinimide (0.45 g, 2.0 mmol), and the resulting mixture was stirred for 5 h in the dark at room temperature. Then the reaction mixture was diluted with 20 mL CH2Cl2 and washed with brine (50 mL × 2). The organic layer was dried over MgSO4, and concentrated under reduced pressure. The residue was purified by flash column chromatography using 3.0% methanol/CH2Cl2 as the

1 eluent to give 45 as a red liquid (1.19 g, 71%). H NMR (400 MHz, CDCl3): δ (ppm) 6.93

(d, J = 8.1 Hz, 1H), 6.64 – 6.56 (m, 2H), 4.19 – 4.15 (m, 2H), 4.06 – 4.02 (m, 2H), 3.90 –

3.88 (m, 2H), 3.73 – 3.52 (m, 132H), 3.40 – 3.31 (m, 10H), 2.60 (s, 6H), 1.50 (s, 6H).

13 C NMR (101 MHz, CDCl3): δ (ppm) 161.53, 156.68, 156.02, 145.10, 139.17, 132.01,

129.82, 116.26, 106.56, 100.66, 85.17, 72.01, 71.08, 70.97, 70.63, 70.47, 69.77, 69.06,

67.77, 59.13, 16.62, 16.05.

Synthesis of compound 46. To a mixture of compound 45 (1.67 g, 1.0 mmol), phenylacetylene (0.31 g, 3.0 mmol), CuI (0.038 g, 0.2 mmol), and Pd(PPh3)4 (0.12 g,

0.1 mmol) was added 10 mL degassed solvent mixture THF:triethylamine (4:1) under argon atmosphere. The resulting mixture was heated to 45 °C and stirred for 16 h in the dark. After cooling to room temperature, the solvent was removed under reduced pressure and the residue was extracted with CH2Cl2/brine. The organic layer was dried over MgSO4, then filtered and condensed. The crude mixture was purified by flash column chromatography using 5.0% methanol/CH2Cl2 to provide 46 as a purple liquid

1 (1.25 g, 77%). H NMR (400 MHz, CDCl3): δ (ppm) 7.44 (m, 4H), 7.34 – 7.27 (m, 6H),

6.99 (d, J = 8.2 Hz, 1H), 6.63 (m, 2H), 4.20 – 4.16 (m, 2H), 4.06 (t, J = 4.6 Hz, 2H), 3.92 79

– 3.88 (m, 2H), 3.77 – 3.48 (m, 106H), 3.43 – 3.35 (m, 10H), 2.68 (s, 6H), 1.64 (s, 6H).

13 C NMR (101 MHz, CDCl3): δ (ppm) 161.37, 157.69, 156.64, 143.73, 140.12, 131.85,

131.30, 129.81, 128.37, 128.10, 123.44, 115.93, 115.66, 106.39, 100.56, 96.31, 81.77,

72.60, 71.93, 71.07, 70.89, 70.57, 70.37, 69.70, 69.01, 67.67, 59.03, 13.66, 13.09.

Synthesis of KS2. To a solution of 46 (0.16 g, 0.1 mmol) and TAC-CHO (0.072 g,

0.1 mmol) in 10 mL solvent mixture n-butanol:toluene (1:1) was added 0.24 mL piperidine and 0.20 mL glacial acetic acid. The resulting mixture was refluxed, and the water formed during the reaction was removed azeotropically by heating overnight in a

Dean-Stark apparatus. Then the solvents were removed under vacuum, and the residue was purified by flash column chromatography using 10% methanol/CH2Cl2. The desired

1 product KS2 was obtained as green gum (0.024 g, 10%). H NMR (400 MHz, CD2Cl2): δ

(ppm) 8.35 (m, 1H), 7.53 – 7.47 (m, 4H), 7.34 (m, 6H), 7.18 – 7.06 (m, 5H), 6.86 (d, J =

7.9 Hz, 2H), 6.73 – 6.62 (m, 6H), 4.26 – 4.03 (m, 16H), 3.77 – 3.05 (m, 197H), 2.72 (s,

13 3H), 2.22 (s, 6H), 1.72 (d, 6H). C NMR (101 MHz, CD2Cl2): δ (ppm) 162.00, 157.38,

153.70, 153.34, 152.72, 151.77, 145.88, 138.88, 137.75, 135.76, 133.18, 131.71,

131.67, 131.45, 131.40, 130.64, 129.06, 128.91, 128.73, 128.62, 125.18, 124.11,

123.96, 122.87, 122.57, 121.99, 121.48, 116.18, 114.55, 113.74, 112.68, 107.05,

100.94, 98.47, 96.91, 84.99, 84.41, 82.45, 72.40, 71.58, 71.45, 71.32, 71.01, 70.88,

70.51, 70.10, 69.77, 69.53, 69.26, 68.49, 68.28, 67.70, 67.15, 59.13, 21.25, 14.27,

13.40, 13.20.

80

III.4.3 Cell culture for imaging

U87MG cells were seeded on poly-D-lysine functionalized 40 mm coverslips in

Petri dishes and incubated in complete MEM medium for 2 d. KS1 was first dissolved in

DMSO to make a stock solution of 2.5 mM, and then diluted with complete MEM medium into 5 µM. Then cells were incubated with 5 µM of KS1 for 10 min. The coverslips were then washed with DPBS and mounted onto a bioptics live cell imaging chamber. For the potassium depletion experiment, a mixture solution of nigericin (5 µM), ouabain octahydrate (10 µM), and bumetanide (10 µM) in complete MEM medium was pumped into cell chambers. For the control experiment, only complete MEM medium was pumped into cell chambers. Cells were kept at 37 °C and imaged with using an

Olympus IX-81 DSU microscope every 30 min.

81

CHAPTER IV: A FLUORESCENCE TURN-ON SENSOR FOR Fe3+

IV.1 Introduction

As the most common element on the earth by mass and the most abundant transition metal in human body, iron is omnipresent in the universe, from the core of the earth to cells of living organisms.352 As an essential element for life, iron plays indispensable roles in a wide range of chemical and biological processes at the cellular level and holds a central position in virtually all organisms.353-354 Both its deficiency and overloading can lead to a variety of diseases.355-356 With the identification of iron as a body constituent in the past century, the importance of iron for mammalian health became clear. The relationship between adequate iron ingest and prevention of certain diseases was well realized.357 Iron performs a major role in electron transfer, oxygen uptake, oxygen metabolism, enzymatic catalysis, and transcriptional regulation.358-366

On the other hand, iron is capable of promoting oxidation of proteins, lipids, and other cellular components. Therefore, iron will be harmful if its level exceeds the capacity of organisms to securely consume it. It has been reported that excessive Fe3+ ions within human body are associated with increased incidence of dysfunction of organs, such as pancreas, liver, and heart, and development of certain diseases including hepatitis, hemochromatosis, and cancers.367-370 Moreover, some recent research has suggested that Fe3+ ions are also involved in the underlying mechanisms of many neurodegenerative diseases, such as Alzheimer’s disease and Parkinson’s disease.371-

374 Therefore, the determination of this biologically significant ion in physiological

82

environment has important consequences and the development of an efficient and reliable approach for the analysis of Fe3+ in biological samples is of much importance and urgency in biological and environmental concerns.

Owing to the advantages of fluorescence technique in comparison to other analytical methods, as introduced in Section I.2, considerable efforts have been devoted to developing fluorescent probes for Fe3+. However, the fluorescent indication of these

Fe3+ probes is mostly signaled by fluorescence quenching due to the paramagnetic nature of Fe3+ ion,375-379 which seriously limits the biological applications of the probes.

Probe 47 is an example of such probes.379 In the absence of Fe3+ ion, probe 47 emits strong fluorescence with a maximum wavelength at 732 nm. Upon the addition of Fe3+, the fluorescence of 47 is dramatically quenched. In the presence of 100 equiv. of Fe3+ ions, almost no fluorescence could be observed from probe 47.

Scheme IV-1. Structures of compounds 47 and 48.

In the past decade, a new type of rhodamine-based fluorescence “turn-on” sensors for Fe3+ ion was developed.74,380-382 The “off-on” fluorescence responses of these dyes are generated from Fe3+-induced transformation from the spirocyclic form,

83

which is not fluorescent, to the highly fluorescent ring-open form of the rhodamine platform. Probe 48 is a rhodamine 6G based “off-on” fluorescent probe for detecting

Fe3+.380 In the absence of Fe3+, probe 48 displays very weak fluorescence, whereas upon the addition of Fe3+ to 48 in an aqueous solution, Fe3+-catalyzed hydrolysis of rhodamine 6G Schiff base occurs, which brings about a strong green fluorescence emission band at 551 nm, corresponding to the spirolactam ring-opened 48. Probe 48 shows high sensitivity and selectivity towards Fe3+ sensing. However, it is not suitable for being explored to sense the dynamic changes of Fe3+ ion concentration due to the irreversible nature of the catalytic hydrolysis reaction.

Scheme IV-2. Structures of compounds 49 and 50.

Recently, an anthracene-bearing bisdiene macrocycle (49) was reported as a

“off-on” fluorescent Fe3+ sensor.383 Probe 49 exhibits reversible fluorescent response when interacting with Fe3+ ions. In an aqueous solution of 49 without Fe3+, very weak fluorescence can be observed. After 4 equiv. of Fe3+ is added, the Fe3+-triggered

84

fluorescence emission enhancement factor is around 5.6-fold according to the emission at 425 nm. After that, the fluorescent emission of probe 49 stabilizes gradually. Upon adding N,N,N’,N’-tetrakis(2-pyridylmethyl)-ethylenediamine (TPEN), which is a strong transition metal chelator, the fluorescent emission spectrum of 49 complexed with Fe3+ is recovered back to its original state.

It’s worth to note here that Bricks et al. synthesized a size-restricted dithiaaza- oxa macrocycle as a recognition unit for Fe3+.384 Probe 50 was obtained through connecting the dithiaaza-oxa macrocycle to a BODIPY fluorophore via a phenyl linker.

The fluorescence response of probe 50 towards Fe3+ is established on a PET process.

As a fluorescence “off-on” probe for Fe3+, 50 displays a moderately selective fluorescence response to Fe3+ ion over the other tested metal cations. Although its sensitivity for Fe3+ sensing is not very high, the design of probe 50 provides an effective prototype for developing PET-based fluorescent Fe3+ sensors via connecting a Fe3+- selective macrocycle to a fluorophore.

Although various fluorescent sensors were designed and synthesized for Fe3+ detection, so far, none of them is able to meet all the requirements for biological application. Therefore, fluorescence “turn-on” sensors, which have high selectivity, sensitivity, and reversibility, and are biocompatible enough to be used in physiological environment, are still in great need.

The goal of this work here is to attempt to develop a fluorescent Fe3+ sensor possessing those above-mentioned required properties. A novel 1,10-diaza-18-crown-6 based cryptand will be synthesized as the Fe3+ recognition unit. Then the cryptand will 85

be conjugated to a BODIPY fluorophore to produce a fluorescent Fe3+-selective sensor

(FeS) which is potential to be used in biological imaging.

IV.2 Results and Discussion

FeS was prepared in 6 steps, beginning with 2-(2-Methoxyethoxy)aniline and

1,10-diaza-18-crown-6 (Scheme IV-3). 2-(2-Methoxyethoxy)aniline reacted with 2- chloroethanol in the presence of CaCO3 and KI under reflux in water to provide compound 51. Then compound 51 was formylated by POCl3 via a Vilsmeier-Haack reaction in DMF to produce compound 52. At the same time, the hydroxyl groups of compound 51 were chlorinated into chloro groups by POCl3. Compound 53 was obtained from the reaction between 1,10-diaza-18-crown-6 and o-acetylsalicyloyl chloride with TEA as the base in CH2Cl2. Then the acetyl groups of compound 53 were hydrolyzed by refluxing with a mixture of NaHCO3 and NH4OAc in aqueous methanol

(1:1) and compound 54 was produced. Compound 55 was prepared through a macrocyclization reaction between compounds 52 and 54 in the presence of KI and

Cs2CO3 in a highly diluted DMF solution at 105 °C. The desired final product FeS in a

13% yield was achieved through a trifluoroacetic acid catalyzed condensation reaction of compound 55 with 2,4-dimethylpyrrole, followed by an oxidation reaction with DDQ and then a chelation reaction with BF3·OEt2 in the presence of TEA.

86

Scheme IV-3. Synthetic route of FeS.a

a Reagents and conditions: (a) 2-chlorethanol, CaCO3, KI, water, reflux, overnight; (b) DMF, POCl3, 0 °C to 60 °C, overnight; (c) TEA, CH2Cl2, room temperature, 2 h; (d) NaHCO3, NH4OAc, aqueous methanol (1:1), reflux, overnight; (e) KI, Cs2CO3, DMF, 105 °C, 6 d; (f) 2,4-dimethylpyrrole, TFA, CH2Cl2, room temperature, overnight; then DDQ, 4 h; then TEA, BF3·OEt2, overnight.

The selectivity of FeS for Fe3+ was first investigated through UV-vis spectroscopy by adding various metal cations , including Li+, Na+, K+, Rb+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+,

Mn2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Ag+, Cd2+, Pb2+, Nd3+, Sm3+, and Er3+, to a solution of

FeS in H2O-CH3CN (9:1, v/v). As shown in Figure IV-1, the free FeS displayed an

87

absorption band at 499 nm. Upon adding Fe3+ ions, the absorption intensity of FeS decreased, while no considerable change was induced to the absorption spectra by the addition of other cations except Cr3+ and Hg2+ ions. The addition of Cr3+ ions resulted in a slight decrease to the absorption intensity of FeS, which however was much weaker than that resulted from Fe3+ ions. Besides Fe3+ and Cr3+ ions, Hg2+ also brought about some changes to the absorption spectra of FeS, including a small red-shift to its maximum absorption wavelength and at the same time a little reduction to its absorption intensity. These results indicate that FeS shows selectivity for detecting Fe3+ over other metal cations.

Figure IV-1. UV-vis absorption spectra of FeS (7 µM) in H2O-CH3CN (9:1, v/v) upon addition of 100 equiv. of various metal cations.

88

In addition, as displayed in Figure IV-2, upon the addition of the first 4 equiv. of

Fe3+ ions, the absorption intensity of FeS decreased gradually. After that, further addition of Fe3+ resulted in no more change to the absorption spectra of FeS.

Figure IV-2. UV-vis spectral changes of FeS (7 µM) in H2O-CH3CN (9:1, v/v) observed upon addition of 1-700 equiv. of Fe3+ ions.

Since fluorescent emission spectroscopy is a more useful tool than absorption spectroscopy in sensing ions, the selectivity of FeS towards Fe3+ detection was further investigated with fluorescent emission spectroscopy. The fluorescent properties of FeS in the presence of the above-mentioned metal cations were studied in a H2O-CH3CN

(9:1, v/v) solution. In good agreement with the findings observed in absorption experiments, FeS exhibited emission responses only to Fe3+, Cr3+, and Hg2+ ions. 89

Figure IV-3 shows visual fluorescence responses of FeS with excitation at 365 nm using a hand-held UV lamp. The free FeS emitted very weak fluorescence in the absence of metal cations. However, different fluorescence responses were induced by the addition of various metal cations. When Fe3+ ions were introduced to a solution of FeS, a striking yellow-green fluorescence emerged very fast, which is a characteristic fluorescent emission of BODIPY dye. Weaker fluorescent emission of FeS was observed in the presence of Cr3+ and Hg2+ ions. The addition of other metal cations of interest induced no apparent fluorescence change.

Figure IV-3. Visual fluorescence responses of FeS (7 µM) in H2O-CH3CN (9:1, v/v) upon addition of 100 equiv. of various metal cations with excitation at 365 nm using a hand-held UV lamp.

Figure IV-4 shows detailed changes in the fluorescent emission spectra of FeS resulted from the addition of various metal cations. Corresponding to the results of visual fluorescence response shown in Figure IV-3, FeS with Fe3+ exhibited an intense emission band at 512 nm. The fluorescence emission intensity was enhanced by 28-fold in the presence of 100 equiv. of Fe3+ ions. In contrast, the addition of 100 equiv. of Cr3+ and Hg2+ ions brought about only 4-fold and 3-fold enhancement in the fluorescence emission intensity of FeS, respectively. In agreement with the forgoing fact that Hg2+ ions resulted in a small red-shift to the maximum absorption wavelength of FeS, the

90

addition of Hg2+ ions also shifted the maximum fluorescence emission wavelength of

FeS from 512 nm to 522 nm besides increasing the fluorescence intensity of FeS. Little to no changes in fluorescence emission spectra of FeS was recorded upon the addition of 100 equiv. of other metal cations. These results demonstrated the desirable selectivity of FeS to Fe3+ ion.

Figure IV-4. Fluorescence emission spectra of FeS (7 µM) in H2O-CH3CN (9:1, v/v) upon addition of 100 equiv. of various metal cations. Inset: Emission intensity of fluorescence emission triggered by different metal cations. 1, blank; 2, Li+; 3, Na+; 4, K+; 5, Rb+; 6, Cs+; 7, Mg2+; 8, Ca2+; 9, Sr2+; 10, Ba2+; 11, Cr3+; 12, Mn2+; 13, Fe2+; 14, Fe3+; 15, Co2+; 16, Ni2+; 17, Cu2+; 18, Zn2+; 19, Ag+; 20, Cd2+; 21, Hg2+; 22, Pb2+; 23, Nd3+; 24, 3+ 3+ Sm ; 25, Er .λex = 480 nm.

To study the sensitivity of FeS toward Fe3+ ion sensing, fluorescence responses of the interaction of FeS with Fe3+ were examined through fluorescence emission titration experiments in a H2O-CH3CN (9:1, v/v) solution. As shown in Figure IV-5, upon

91

progressive addition of 1-700 equiv. of Fe3+ ions, the fluorescence intensity of FeS was gradually increased.

Figure IV-5. Enhancements in fluorescence emission spectra of FeS (7 µM) in H2O- 3+ CH3CN (9:1, v/v) upon continuous addition of 1-700 equiv. of Fe ions. λex = 480 nm.

Figure IV-6A exhibits the fluorescent intensity of FeS as a function of the equiv. of added Fe3+ ions. The initial addition of 20 equiv. of Fe3+ ions brought about a dramatic enhancement in the fluorescence emission intensity of FeS. Following that, the rate of Fe3+-induced fluorescence increase slowed down as more Fe3+ ions added to the solution of FeS in the subsequent titration procedure till 300 equiv. of Fe3+ ions was added. Then the fluorescent emission intensity gradually stabilized. More importantly,

92

as displayed in Figure IV-6B, in the range of 1-20 equiv. of added Fe3+ ions, a linear relationship was found between the fluorescence intensity enhancement (FI-FI0, FI: fluorescence intensity) of FeS and the equiv. of Fe3+ ions (R2 = 0.9977). Therefore, FeS is potential to be a quantitative sensor for measuring the concentration of Fe3+ ion.

Figure IV-6. (A) Fluorescence emission intensity of FeS as a function of the equiv. of 3+ 3+ added Fe . (B) Plot of FI-FI0 (FI: fluorescence intensity) versus the equiv. of Fe ion in the range of 1-20 equiv. of Fe3+ ions.

Besides selectivity and sensitivity, the reversibility of FeS was also investigated because it is an important property for an ion sensor. TPEN (N,N,N’,N’-tetrakis(2- pyridylmethyl)ethylenediamine), a strong Fe3+ chelator, was used to free FeS from its

Fe3+-complexed form. As shown in Figure IV-7, when 20 equiv. of Fe3+ ions was added to FeS in H2O-CH3CN (9:1, v/v), a remarkable fluorescent emission increase was observed. Then TPEN was added to the solution and it instantly decreased the fluorescence intensity of the solution. Upon the addition of 60 equiv. of TPEN (3 equiv. for Fe3+), the fluorescence emission spectrum of FeS with 20 equiv. of Fe3+ ions was 93

recovered back to the original spectrum of free FeS. These results indicate the good reversibility of FeS for Fe3+ ion detection.

Figure IV-7. Fluorescence response reversibility of FeS (7 µM) in H2O-CH3CN (9:1, v/v). Fluorescence emission spectra of free FeS, FeS with 20 equiv. of Fe3+, and FeS with 20 3+ equiv. of Fe and 60 equiv. of TPEN. λex = 480 nm.

Furthermore, the pH sensitivity of FeS was also investigated in H2O-MeCN (9:1, v/v) solutions with different pH values between 2.0 and 9.0. As displayed in Figure IV-8, no apparent change of the fluorescence emission spectra of FeS was observed in the pH range of 3.2-9.0. When the pH of the sample was reduced to 3.0, a mild enhancement in the fluorescence intensity of FeS was recorded. Further decreased pH values brought about stronger fluorescence emission. These results indicate that FeS is pH insensitive in the physiological pH range (6.8-7.4). 94

Figure IV-8. Fluorescence emission spectra of FeS (7 μM) in H2O-MeCN (9:1, v/v) at different pH. λex = 480 nm.

Encouraged by the above results, FeS was applied to sensing Fe3+ ion in living cells. HCT-116 cells were used to conduct these experiments. Figure IV-9 shows the viability of HCT-116 cells after incubation with different concentrations of FeS. No obvious toxicity was found from cells incubated with up to 25 µM of FeS, which means

FeS is potentially suitable for sensing Fe3+ ions in living cells.

95

Figure IV-9. Viability of HCT-116 cells incubated with different concentrations of FeS.

Cell imaging experiments were performed to determine the sensing ability of FeS for Fe3+ ions in living cells. Based on the results obtained from cell viability experiments,

FeS was used at a concentration of 20 µM in cell imaging experiments. Fluorescence images and phase contrast images of HCT-116 cells incubated with FeS are shown in

Figure IV-10. First, HCT-116 cells were incubated with a 20 µM solution of FeS in MEM medium for 10 min. Then a 30 µM solution of Fe3+ in MEM medium was injected into the chambers containing HCT-116 cells and cells were immediately imaged (image IV-10a).

The same MEM medium without Fe3+ ions was used in the control experiment (image

IV-10d). Then cells were imaged every 10 min. 60 min later, a much stronger fluorescence signal was recorded for cells incubated with Fe3+ solution (image IV-10b).

96

However, cells treated with only MEM medium in the control experiment exhibited no obvious change in images (image IV-10e).

Figure IV-10. Images of live HCT-116 cells in a 30 µM Fe3+ solution in MEM medium (a- c) and in only MEM medium (d-f) at 0 min (a, d) and 60 min (b, e) after incubated with FeS (20 µM). Images c and f are the phase contrast images of b and e, respectively.

Figure IV-11 shows the average fluorescence emission intensity of images of

HCT-116 cells taken at different time points. The fluorescence signal change of cells is quantitatively demonstrated by comparing the fluorescence intensity data of cell images taken at different time. As displayed by curve B in Figure IV-11, cells incubated with

Fe3+ solution emitted gradually increased fluorescence as the incubation time getting longer. In contrast, fluorescence emission intensity of HCT-116 cells without Fe3+ incubation stayed fairly constant (curve A in Figure IV-11). Besides, the phase contrast images (images IV-10c and IV-10f) showed that those cells were still in good conditions. 97

These results demonstrate that FeS is capable of sensing Fe3+ ion in living cells without causing considerable damages to cells.

Figure IV-11. Average fluorescence intensity of cell images at different time points. (A) Control experiment; (B) Fe3+ sensing experiment.

IV.3 Conclusion

In summary, a novel BODIPY-based selective, sensitive and reversible fluorescence turn-on sensor (FeS) for Fe3+ ion detection was synthesized and characterized. FeS is a conjugate of two moieties, a BODIPY platform serving as the fluorophore and a 1,10-diaza-18-crown-6 based cryptand acting as the Fe3+ recognition moiety. FeS exhibited selective fluorescence turn-on response toward Fe3+ over other

98

metal cations of interest, including Cr3+ and Hg2+ ions, which are the most common interfering metal cations for Fe3+ detection. Also, FeS demonstrated high sensitivity for

Fe3+ sensing. A linear relationship was found between the fluorescence intensity enhancement and the equiv. of added Fe3+ ion. Moreover, the turn-on fluorescence response of FeS to Fe3+ ion was reversible. Treatment of Fe3+-loaded FeS with TPEN restores the fluorescence emission back to baseline levels. In addition, FeS is insensitive to the pH of the physiological environment. Based on its excellent performance in Fe3+ sensing and very low cytotoxicity, FeS was successfully applied to live cell imaging of Fe3+.

IV.4 Experimental

IV.4.1 General

All reagents and solvents were purchased from commercial suppliers and used without further purification. All metal cations were purchased as their chloride, sulfate or nitrate salts and used as received. 1H and 13C NMR spectra were carried out on a

Bruker AVANCE spectrometer (400 MHz). HR-MS analyses were performed at the

Department of Chemistry, University of Florida. Fluorescence emission spectra were measured using an FLS980 fluorescence spectrometer. Fluorescence microscopy images were recorded on an Olympus IX-81 DSU microscope equipped with a

Hamamatsu EM-CCD C9100 digital camera using a FITC filter cube (Ex: 477/50; DM:

507; Em: 536/40) and a 20x (Olympus LUCplanFLN 20x, N.A. = 0.45) objective lens.

99

IV.4.2 Synthesis

Synthesis of compound 51. A mixture of 2-methoxyethoxyaniline (16.7 g, 100 mmol), 2-chloroethanol (40.3 g, 500 mmol), KI (33.2 g, 200 mmol) and CaCO3 (20.0 g,

200 mmol) in water (150 mL) was refluxed overnight under argon atmosphere. After cooling to room temperature, the resulting mixture was filtered and the filtrate was extracted with ethyl acetate (150 mL × 3). The combined organic phase was dried over

MgSO4, concentrated in vacuo, and the residue was purified by flash column chromatography on silica gel using ethyl acetate/methanol (99/1) to give compound 51

1 as colorless liquid (30.1 g, 90%). H NMR (400 MHz, CDCl3): δ (ppm) 7.22 (dd, J = 7.8,

1.7 Hz, 1H), 7.13 (td, J = 8.1, 1.7 Hz, 1H), 7.00 (td, J = 7.8, 1.4 Hz, 1H), 6.92 (dd, J =

8.1, 1.4 Hz, 1H), 4.15 – 4.10 (m, 2H), 3.78 – 3.74 (m, 2H), 3.61 (s, 2H), 3.51 – 3.46 (m,

13 4H), 3.45 (s, 3H), 3.20 – 3.13 (m, 4H). C NMR (101 MHz, CDCl3): δ (ppm) 155.38,

139.27, 126.18, 125.62, 122.35, 113.37, 70.76, 67.87, 59.70, 59.02, 58.08.

Synthesis of compound 52. To a solution of 51 (2.55 g, 10 mmol) in dry DMF (20 mL) was added POCl3 (7.77 g, 50 mmol) dropwise under argon atmosphere at 0 °C.

The resulting mixture was warmed to room temperature and then slowly heated to 60 °C.

After stirring at 60 °C overnight, the reaction mixture was cooled to room temperature and then slowly poured into ice water. The excess POCl3 was quenched by the addition of Na2CO3 powder. The mixture was extracted with CH2Cl2 (100 mL × 2) and the combined extracts were concentrated. The residue was then dissolved in ethyl acetate

(100 mL) and the solution was washed with brine (100 mL × 2), dried over MgSO4, and evaporated. The crude mixture was purified by flash column chromatography on silica 100

gel using hexane/ethyl acetate (4/1), giving the desired compound 52 as light yellow

1 liquid (1.60 g, 50%). H NMR (400 MHz, CDCl3): δ (ppm) 3.44 (s, 3H), 3.64 – 3.73 (m,

8H), 3.76 – 3.80 (m, 2H), 4.16 – 4.22 (m, 2H), 6.94 (d, J = 8.2, 1H), 7.35 – 7.43 (m, 2H),

13 9.80 (s, 1H). C NMR (101 MHz, CDCl3): δ (ppm) 41.44, 55.04, 59.12, 67.96, 70.79,

111.36, 117.17, 126.69, 130.11, 144.00, 150.69, 190.67. HRMS (ESI, m/z): calcd for

+ C14H19Cl2NO3 ([M+H] ) 320.0815; found 320.0830.

Synthesis of compound 53. To a solution of 1,10-diaza-18-crown-6 (2.62 g, 10 mmol) in 5 mL triethylamine and 40 mL anhydrous CH2Cl2 was added o-acetylsalicyloyl chloride (4.97 g, 25 mmol) in one portion at room temperature. A white suspension formed rapidly. The reaction mixture was stirred for 2 h at room temperature and then was diluted with CH2Cl2 (60 mL). The solution was transferred to a separation funnel and washed with brine (100 mL × 2), dried over MgSO4, and concentrated under reduced pressure. The residue was purified by flash column chromatography on silica gel using CH2Cl2/methanol (50/1) as the eluent to give 53 as yellow liquid (4.94 g, 84%).

1 H NMR (400 MHz, CDCl3): δ (ppm) 2.25 (d, J = 8.5, 6H), 3.44 – 3.87 (m, 24H), 7.13 –

7.20 (m, 2H), 7.21 – 7.26 (m, 2H), 7.27 – 7.32 (m, 2H), 7.36 – 7.43 (m, 2H). 13C NMR

(101 MHz, CDCl3): δ (ppm) 20.99, 45.91, 49.49, 49.57, 69.57, 70.20, 70.65, 70.72,

123.15, 126.06, 127.67, 130.04, 130.18, 146.92, 168.44, 169.00. HRMS (ESI, m/z):

+ calcd for C30H38N2O10 ([M+H] ) 587.2599; found 587.2605.

Synthesis of compound 54. 80 ml aqueous methanol (1:1) was added to a mixture of compound 53 (4.11 g, 7 mmol), ammonium acetate (2.16 g, 28 mmol) and

NaHCO3 (2.35 g, 28 mmol). The resulting mixture was heated to reflux and stirred 101

overnight. After cooling to room temperature, the reaction mixture was diluted with 40 mL water and then filtered. The white residue was washed with H2O and dried under vacuum, providing the desired compound 54 as white solid (3.24 g, 92%). 1H NMR (400

MHz, CDCl3): δ (ppm) 3.64 (s, 8H), 3.79 (t, J = 2.7, 16H), 6.81 – 6.86 (m, 2H), 6.97 (d, J

13 = 8.0, 2H), 7.28 – 7.33 (m, 4H), 9.22 (s, 2H). C NMR (101 MHz, CDCl3): δ (ppm) 69.66,

70.74, 118.00, 118.59, 118.82, 127.86, 132.28, 157.90, 172.14. HRMS (ESI, m/z): calcd

+ for C26H34N2O8 ([M+H] ) 503.2388; found 503.2407.

Synthesis of compound 55. A solution of compound 52 (0.32 g, 1.0 mmol) and KI

(0.37 g, 2.2 mmol) in 100 ml dry DMF was heated to 60 °C and stirred for 2 h at that temperature to make solution 1. A mixture of compound 54 (0.50 g, 1.0 mmol) and

Cs2CO3 (0.98 g, 3.0 mmol) in 100 ml dry DMF was degased by argon for 30 min and then heated to 105 °C. After stirring for 1.5 h, the resulting mixture was added solution 1 dropwise over 4 h under argon atmosphere. The reaction mixture was stirred at 105 °C for 6 d. After cooling to room temperature, DMF was removed under reduced pressure.

The residue was added 20 mL water and extracted with CH2Cl2 (20 mL × 2). The combined extracts were washed three times with water and then once with brine. The organic layer was dried over MgSO4, filtered and concentrated in vacuo. Purification by flash column chromatography on silica gel using ethyl acetate/methanol (20/1) provided

1 55 as yellow solid (0.15 g, 20%). H NMR (400 MHz, CDCl3): δ (ppm) 3.34 – 4.21 (m,

39H), 6.90 (d, J = 8.1, 2H), 6.95 – 7.03 (m, 3H), 7.16 – 7.21 (m, 2H), 7.27 – 7.32 (m,

13 2H), 7.35 – 7.41 (m, 2H), 9.77 (d, 1H). C NMR (101 MHz, CDCl3): δ (ppm) 46.58,

49.22, 54.33, 59.02, 59.12, 67.68, 69.04, 69.59, 70.84, 70.91, 71.17, 71.32, 110.33, 102

112.60, 113.28, 115.56, 121.40, 121.85, 126.74, 127.29, 127.49, 127.77, 129.33,

130.47, 145.11, 150.19, 154.34, 154.57, 169.66, 169.86, 190.69. HRMS (ESI, m/z):

+ calcd for C40H51N3O11 ([M+H] ) 750.3596; found 750.3613.

Synthesis of FeS. To a solution of compound 55 (0.38 g, 0.5 mmol) and 2,4- dimethylpyrrole (0.11 g, 1.1 mmol) in degased CH2Cl2 (50 mL) was added 2 drops of trifluoroacetic acid under argon atmosphere. The mixture was stirred at ambient temperature overnight, then a mixture of 2,3-dichloro-5,6-dicyano-p-benzoquinone (0.14 g, 0.6 mmol) in CH2Cl2 (10 mL) was added. The reaction mixture was stirred continuously for another 4 h. After the addition of 3 mL triethylamine, 3 mL BF3·OEt2 was added dropwise to the mixture. The mixture was kept stirring at ambient temperature overnight, then filtered through a celite pad. The residue was washed with

20 mL CH2Cl2 and the combined filtrate was rotary evaporated to dryness. The residue was dissolved in 30 mL CH2Cl2 and the solution was washed with 30 mL 5% aqueous

NaHCO3 solution followed with water (30 mL × 2). The organic portion was dried over anhydrous MgSO4, filtered and then evaporated in vacuo. The crude product was purified by flash column chromatography on silica gel using CH2Cl2/methanol (25/1) as

1 the eluent to give FeS as red solid (0.063 g, 13%). H NMR (400 MHz, CDCl3): δ (ppm)

1.48 (s, 6H), 2.55 (s, 6H), 2.95 – 4.34 (m, 39H), 5.98 (s, 2H), 6.76 – 7.02 (m, 6H), 7.08

13 – 7.24 (m, 3H), 7.26 – 7.31 (m, 2H). C NMR (101 MHz, CDCl3): δ (ppm) 14.46, 14.57,

14.73, 46.64, 49.25, 49.64, 54.45, 59.12, 59.18, 67.79, 68.38, 68.98, 69.66, 69.95,

70.19, 70.82, 70.88, 70.99, 71.14, 71.24, 71.37, 112.40, 112.62, 112.97, 114.05, 119.75,

121.03, 121.18, 121.28, 121.51, 121.59, 126.83, 127.25, 127.62, 127.78, 128.63, 103

128.83, 130.37, 131.78, 138.75, 139.92, 141.66, 143.09, 152.45, 152.87, 154.49,

+ 154.67, 155.54, 169.70, 169.83. HRMS (ESI, m/z): calcd for C52H64N5O10BF2 ([M+H] )

968.4796; found 968.4832.

IV.4.3 Cell culture for imaging

Epithelial colorectal carcinoma cells (HCT-116) were cultured in RPMI cell medium supplemented with 10% fetal bovine serum and 1% penicillin and streptomycin at 37 °C and 5% CO2. Then cells were seeded onto a 40 mm glass slide, which was later mounted onto a bioptics live cell imaging chamber after cells were incubated with a

20 µM solution of FeS in MEM medium for 10 min. For the Fe3+ sensing experiment, a

30 µM Fe3+ solution in MEM medium was pumped into cell chambers. For the control experiment, only MEM medium was pumped into cell chambers. Cells were kept at

37 °C and imaged with Olympus IX-81 DSU microscope every 10 min.

104

CHAPTER V: A FLUORESCENCE TURN-ON SENSOR FOR Ca2+

V.1 Introduction

Calcium, a major component in the mineralization of teeth, shells, and bones, is the most abundant metal by mass in many animals. Approximately 99% of calcium in human body is stored in teeth and bones. Calcium is also the fifth-most-abundant element in the earth's crust by mass, and the fifth-most-abundant ion by both mass and molarity in seawater.

Calcium is an essential mineral for living organisms and an important component of a healthy diet. The National Osteoporosis Foundation states, "Calcium plays an important role in building stronger, denser bones early in life and keeping bones strong and healthy later in life." Except the roughly 99% calcium stored in teeth and bones, the rest of calcium in human body has some other important functions. In cell physiology, calcium ions are important second messengers used in signal transduction.60 Their movement in and out of cytoplasm works as a signal for many cellular processes.385

Calcium plays a pivotal role in muscle contraction, which was discovered as early as in

1882. Also, calcium ions are important for maintaining the potential difference across excitable cell membranes. Moreover, calcium ions are required as a cofactor for many enzymes to function regularly, for example, the enzymes of blood-clotting cascade.

Calcium is of such importance to the physiology and biochemistry of animals that its levels are tightly maintained within specific limits, with bones as the storage site.386

Both calcium deficiency and calcium overloading can bring about harmful

105

consequences. Low concentrations of extracellular calcium may lead to hypokalemic tetany. Long-term calcium deficiency can result in poor blood coagulation, rickets, and even osteoporosis. On the other hand, calcium overloading may cause damage to cells, leading to apoptosis or death by necrosis. Furthermore, long-term calcium overloading is associated with hyperkalemia, decreased neuromuscular excitability, impaired kidney function, cardiac arrhythmias, and decreased absorption of other minerals. It has also been reported that high calcium intake is in relation to prostate cancer.387

Due to the vital role of calcium for human health, developing fluorescent calcium probes for physiological applications has been the focus of chemical and biological researchers for a quite long time. In this regard, Tsien et al. made significant contributions. In 1980, Tsien reported the synthesis of 1,2-bis(o-aminophenoxy)ethane-

N,N,N’,N’-tetraacetic acid (BAPTA), which is a well-known recognition unit for calcium ions.388 By conjugating BAPTA to different chromophores, Tsien et al. synthesized various fluorescent calcium probes.28,210 The first series of fluorescent probes for calcium reported by Tsien et al. include Stil-1, Stil-2, Indo-1, Fura-1, Fura-2, and Fura-3, which are all UV light-excited probes.210 Among these fluorescent probes, Indo-1and

Fura-2 are the most preferred because of their relatively large fluorescence signal changes upon binding calcium ions. However, their absorption in the UV region seriously limits their applications in cellular environment. To solve this problem, Tsien et al. afterwards developed some other fluorescent calcium probes that can be excited by visible light, including Rhod-1, Rhod-2, Fluo-1, Fluo-2, and Fluo-3.28 In these probes, a

BAPTA group is typically linked to a rhodamine or fluorescein fluorophore. The 106

maximum absorption and emission wavelengths of these probes are all in the visible region. These probes exhibit high selectivity and sensitivity towards calcium ion sensing.

They are capable of detecting calcium at a concentration as low as 100 nM. As known, the intracellular and extracellular levels of calcium ion are around 100 nM and 1.0 mM, respectively.386 Therefore, these probes are potential for sensing intracellular calcium ions.

Scheme V-1. Structures of Stil-1, Stil-2, Indo-1, Fura-1, Fura-2, Fura-3, Rhod-1, Rhod-2.

107

Scheme V-2. Structures of Fluo-1, Fluo-2, and Fluo-3.

However, the salt forms of these probes are not able to permeate the cell membrane, which prevents them from being up-taken by cells. As a consequence, it is necessary to use some techniques such as microinjection and electrophoration to put the probes into cells, which highly limits their application in cellular environment because of the inconvenience of those techniques. To address this problem, Tsien et al. developed a non-disruptive approach for loading these calcium probes into cells.27 The

BAPTA group of the probes is made temporarily membrane permeable by masking its four carboxylates with esterifying groups, producing the so-called acetoxymethyl esters

(AM esters). The AM ester form of the calcium probes can easily get into cells and then hydrolyses inside the cells with intracellular esterases as the catalyst, regenerating and trapping the original probes in the cells.

Following Tsien’s work, a variety of new BAPTA-based fluorescent probes for calcium ion determination were reported over the past decade.43-44,52,55-56,59-61,389-390

Some of these probes have been used to image calcium ions in vivo and monitor the change of intracellular levels of calcium ions in various cells, consequently leading to considerable improvements in understanding the functions of calcium ion in physiology

108

and biology.43-44,389 Compound 56 is a fluorescence “turn-on” calcium probe prepared by attaching a BAPTA group to a BODIPY fluorophore at the meso-position.59 Upon binding with calcium ions, the probe displays a 250-fold increase in fluorescence emission intensity. This probe is suitable for monitoring the intracellular calcium level change with high spatiotemporal resolution due to its high sensitivity for calcium detection. Compound 57 is another BODIPY-based fluorescent probe for calcium ions, using BAPTA as the recognition moiety.61 This probe exhibits desirable spectroscopic properties. In the presence of calcium ions, probe 57 shows very intense NIR fluorescence emission at 670 nm. It has been explored in real-time imaging of intracellular calcium ions. Compound 58 is also an NIR fluorescence “turn-on” sensor for calcium ions.60 This probe incorporates a Si-rhodamine platform as the fluorophore and a BAPTA unit as the calcium chelator. Upon complexation with calcium ions, probe

58 demonstrated over 1000-fold fluorescence emission intensity enhancement. The most important advantages of probe 58 in comparison to other existing fluorescent calcium probes, including its high signal-to-background ratio and NIR fluorescence characteristic, make it a much more suitable sensor for fluorescence imaging of calcium ions in neuronal systems.

Due to the attractive properties of two-photon excitation microscopy, as introduced in Section I.1, some 2PA fluorescent calcium probes have been developed in recent years by connecting the BAPTA group to certain fluorophores with high 2PA cross sections.52,55-56 Compound 59 is a 2PA fluorescent probe for calcium ions.52 The maximum 2PA wavelength of 59 is 780 nm and the cross section is 110 GM. The 109

complexation of probe 59 with calcium ions brings about a 44-fold increase in its fluorescent emission intensity. This probe is capable of selectively detecting dynamic levels of intracellular free calcium ions in living cells and monitoring the Ca2+ waves at a depth of about 150 mm in living tissues through two-photon excitation microscopy.

Scheme V-3. Structures of compounds 56, 57, 58, and 59.

Although the fluorescent calcium probes developed by Tsien et al. are often used as the gold standard and are currently the most widely used sensors in intracellular calcium detection due to their commercial availability, other progress has been made in this field to date. All these above-mentioned calcium probes (compounds 56-59) and other newly developed ones have exhibited preferable properties. They are promising for applications in the areas of biological and physiological calcium study. 110

However, these probes are only suitable for sensing intracellular levels of calcium ions because of their high bonding strength with calcium. Therefore, fluorescent calcium probes with weaker binding affinity to calcium ions are still in great need. Such probes should be capable of determining calcium ions at extracellular concentrations in whole blood, serum, and plasma. Herein, the goal of this work is to design and synthesize a fluorescent calcium sensor that will be suitable for sensing calcium levels in extracellular environments.

V.2 Results and Discussion

As shown in Scheme V-4, synthesis of the calcium sensor (CaS) started with 2-

(2-methoxyethoxy)aniline that was reacted with 2-chloroethanol in the presence of

CaCO3 and KI under reflux in water to provide compound 51. Then 51 was treated with

NaH in THF at room temperature for 1 h, followed by the dropwise addition of t-butyl bromoacetate at 0 °C. The resulting reaction mixture was stirred at room temperature overnight to produce compound 60 as a colorless liquid. Compound 61 was obtained through a Vilsmeier–Haack reaction of compound 60 in the presence of POCl3 in DMF.

Compound 62 was prepared via a condensation reaction of compound 61 with 2,4- dimethylpyrrole in CH2Cl2 in the presence of a catalytic amount of TFA at room temperature, followed by an oxidation reaction with DDQ and a subsequent chelation reaction with BF3·OEt2 in the presence of TEA at room temperature. Then a TFA catalyzed hydrolysis reaction was performed to compound 62 at room temperature in

CH2Cl2 to achieve the desired final product CaS as a red solid. 111

Scheme V-4. Synthetic route of CaS.a

a Reagents and conditions: (a) 2-chlorethanol, CaCO3, KI, water, reflux, overnight; (b) NaH, THF, room temperature, 1 h, then 0 °C, t-butyl bromoacetate, then room temperature, overnight; (c) DMF, POCl3, 0 °C to 60 °C, overnight; (d) 2,4-dimethylpyrrole, TFA, CH2Cl2, room temperature, overnight; then DDQ, 4 h; then TEA, BF3·OEt2, overnight; (e) TFA:CH2Cl2 (1:3), room temperature, 1 h.

After CaS was synthesized, its selectivity as a sensor for Ca2+ was first studied in

30 mM HEPES buffer (pH 7.4). Figure V-1 shows the fluorescent emission spectra of

CaS in the presence of various biological metal cations at their physiological concentrations. Without metal cations added, the free CaS emitted only weak fluorescence at 511 nm. Upon the addition of Ca2+ ions, a dramatically enhanced fluorescence emission signal was observed. Besides Ca2+, the presence of Zn2+ also brought about a mild increase in the fluorescence intensity of CaS, which was much 112

weaker than that induced by Ca2+. Little to no changes in the fluorescence spectra of

CaS was recorded upon the addition of other metal cations. These results demonstrated the desirable selectivity of CaS towards Ca2+ determination. In addition, the same phenomena were also found in widely used BAPTA-based fluorescent Ca2+ probes, which also suffer from the interference of Zn2+.28,52,390

Figure V-1. Fluorescence emission spectra of CaS (5 μM) in 30 mM HEPES buffer (pH 7.4) upon addition of various biological metal cations at their physiological concentrations: Li+ (1.0 mM), Na+ (150 mM), K+ (150 mM), Mg2+ (2.0 mM), Ca2+ (1.0 2+ 2+ 3+ 2+ 2+ mM), Zn (50 μM), Cu (50 μM), Fe (50 μM), Co (50 μM), Ni (50 μM). λex = 480 nm.

To investigate the efficiency of CaS towards Ca2+ sensing, titration experiments were performed in 30 mM HEPES buffer (pH 7.4) solutions. Initially, UV-vis absorption spectroscopy was utilized to conduct titration experiments. As displayed in Figure V-2, in the absence of Ca2+ ions, the solution of CaS exhibited an absorption peak at 498 nm. 113

Upon the progressive addition of Ca2+ ions, the absorption intensity of the sample was slightly decreased.

Figure V-2. Absorption spectra of CaS (5 μM) in 30 mM HEPES buffer (pH 7.4) upon continuous addition of 7.0 mM Ca2+ ions.

As fluorescence emission spectroscopy is a more effective and reliable approach than absorption spectroscopy for titration experiments, the Ca2+ sensing efficiency of

CaS was further examined by fluorescence emission titration experiments in 30 mM

HEPES buffer (pH 7.4). As demonstrated in Figure V-3, a gradual increase in the fluorescence intensity of CaS was observed upon continuous addition of Ca2+ ions. The fluorescence intensity was enhanced by 18-fold in the presence of 7.0 mM Ca2+. The addition of more Ca2+ ions was not able to further enhance the fluorescence intensity of

CaS. Furthermore, CaS was capable of detecting 0.1 mM Ca2+, which indicated good sensitivity. Given that the average concentration of ionized calcium is around 1.0 mM in 114

blood, serum, and plasma, CaS is potentially suitable for determining Ca2+ levels in those fluids.

Figure V-3. Enhancement in fluorescence emission spectra of CaS (5 μM) in 30 mM 2+ HEPES buffer (pH 7.4) upon continuous addition of 7.0 mM Ca . λex = 480 nm.

In addition, the sensitivity of CaS to pH was investigated in aqueous solutions within a pH range between 4.0 and 8.0. As displayed in Figure V-4, when the pH of the solution was over 6.8, no apparent change was observed in the fluorescence emission spectra of CaS. However, when the pH value was as low as 6.6, fluorescence intensity of CaS was moderately increased. Even lower pH values resulted in stronger fluorescence emission until the pH of the solution reached 4.0. These results demonstrate that CaS is pH insensitive in the physiological pH range, especially in blood and serum where the pH is buffered at 7.4.

115

Figure V-4. Fluorescence emission spectra of CaS (5 μM) in water at different pH. λex = 480 nm.

V.3 Conclusion

In summary, a novel BODIPY-based fluorescence turn-on sensor (CaS) has been designed and synthesized for selectively and sensitively determining Ca2+. CaS is comprised of two moieties, a BODIPY fluorophore and a Ca2+ complexing unit. CaS demonstrates selective fluorescence off-on response towards Ca2+ over other metal cations of interest. Although Zn2+ can also trigger a fluorescence response, the increase in fluorescence intensity induced by Zn2+ is much weaker than that by Ca2+. Moreover,

CaS demonstrated desirable sensitivity for Ca2+ detection, which makes it more suitable for extracellular Ca2+ determination than other known probes. In addition, CaS is insensitive to the pH of the physiological environment, especially to that in blood and

116

serum. Therefore, based on the advantages of CaS, it holds great potential for sensing

Ca2+ ions in extracellular environments.

V.4 Experimental

V.4.1 General

All reagents and solvents were purchased from commercial suppliers and used without further purification. All metal cations were purchased as their chloride, sulfate or nitrate salts and used as received. 1H and 13C NMR spectra were carried out on a

Bruker AVANCE spectrometer (400 MHz). HR-MS analyses were performed at the

Department of Chemistry, University of Florida. Flash column chromatography was performed on a CombiFlash® Rf+ automated flash chromatography using RediSep Rf

Gold® normal-phase HP silica columns. UV-vis absorption spectra were recorded on an

Agilent 8453 spectrophotometer. Fluorescence emission spectra were measured using an FLS980 fluorescence spectrometer.

V.4.2 Synthesis

Synthesis of compound 60. To a solution of 51 (5.11 g, 20 mmol) in 100 mL anhydrous THF was added 60% NaH in mineral oil (0.84 g, 21 mmol) in one portion under argon atmosphere at room temperature. The reaction mixture was stirred for 1 h at room temperature and then was cooled to 0 °C. A solution of tert-butyl bromoacetate

(4.68 g, 24 mmol) in 5 mL anhydrous THF was added dropwise at 0 °C. The resulting mixture was warmed to room temperature and stirred for 4 h. Then the reaction was quenched by 100 mL water and transferred to a separation funnel. The water layer was 117

extracted with ethyl acetate (50 mL × 2). The combined organic layer was washed with brine (100 mL × 2), dried over MgSO4, and concentrated under reduced pressure. The residue was purified by flash column chromatography using hexane/ethyl acetate (3/1)

1 as the eluent to give 60 as colorless liquid (1.94 g, 20%). H NMR (400 MHz, CDCl3): δ

(ppm) 7.04 (dd, J = 7.5, 1.9 Hz, 1H), 6.94 – 6.83 (m, 3H), 4.12 (dd, J = 5.5, 4.4 Hz, 2H),

3.92 (s, 4H), 3.74 (dd, J = 5.5, 4.4 Hz, 2H), 3.61 (t, J = 6.2 Hz, 4H), 3.47 (t, J = 6.2 Hz,

13 4H), 3.42 (s, 3H), 1.45 (s, 18H). C NMR (101 MHz, CDCl3): δ (ppm) 169.87, 152.77,

139.69, 122.79, 122.19, 121.47, 114.28, 81.48, 71.30, 69.99, 69.09, 67.89, 59.13, 52.74,

+ 28.23. HRMS (ESI, m/z): calcd for C25H41NO8 ([M+H] ) 484.2905; found 484.2916.

Synthesis of compound 61. To a solution of 60 (4.84 g, 10 mmol) in dry DMF (20 mL) was added POCl3 (7.77 g, 50 mmol) dropwise under argon atmosphere at 0 °C.

The resulting mixture was warmed to room temperature and then slowly heated to 60 °C.

After stirring at 60 °C overnight, the reaction mixture was cooled to room temperature and then slowly poured into ice water. The excess POCl3 was quenched by the addition of NaOH. The mixture was extracted with CH2Cl2 (100 mL × 2) and the combined extracts were concentrated. The residue was then dissolved in ethyl acetate (100 mL) and the solution was washed with brine (100 mL × 2), dried over MgSO4, and evaporated. The crude mixture was purified by flash column chromatography using hexane/ethyl acetate (3/1), giving the desired compound 61 as light yellow liquid (2.08 g,

1 41%). H NMR (400 MHz, CDCl3): δ (ppm) 9.75 (s, 1H), 7.36 (dd, J = 8.3, 1.8 Hz, 1H),

7.32 (d, J = 1.8 Hz, 1H), 7.02 (d, J = 8.3 Hz, 1H), 4.15 (dd, J = 5.4, 3.8 Hz, 2H), 3.94 (s,

13 4H), 3.76 – 3.67 (m, 10H), 3.41 (s, 3H), 1.45 (s, 18H). C NMR (101 MHz, CDCl3): δ 118

(ppm) 190.66, 169.71, 150.22, 145.96, 128.90, 127.11, 117.34, 111.35, 81.68, 70.91,

70.10, 69.11, 67.83, 58.99, 52.55, 28.23. HRMS (ESI, m/z): calcd for C26H41NO9

([M+H]+) 512.2854; found 512.2852.

Synthesis of compound 62. To a solution of compound 61 (0.26 g, 0.5 mmol) and

2,4-dimethylpyrrole (0.11 g, 1.1 mmol) in degased CH2Cl2 (50 mL) was added 2 drops of trifluoroacetic acid under argon atmosphere. The mixture was stirred at ambient temperature overnight, then a mixture of 2,3-dichloro-5,6-dicyano-p-benzoquinone (0.14 g, 0.6 mmol) in CH2Cl2 (10 mL) was added. The reaction mixture was stirred continuously for another 4 h. After the addition of 3 mL triethylamine, 3 mL BF3·OEt2 was added dropwise to the mixture. The mixture was kept stirring at ambient temperature overnight, then filtered through a celite pad. The residue was washed with

20 mL CH2Cl2 and the combined filtrate was rotary evaporated to dryness. The residue was dissolved in 30 mL CH2Cl2 and the solution was washed with 30 mL 5% aqueous

NaHCO3 solution followed with water (30 mL × 2). The organic portion was dried over anhydrous MgSO4, filtered and then evaporated in vacuo. The crude product was purified by flash column chromatography using hexane/ethyl acetate (4/1) as the eluent

1 to give 62 as red gum (0.054 g, 15%). H NMR (400 MHz, CDCl3): δ (ppm) 7.14 (d, J =

8.1 Hz, 1H), 6.82 – 6.72 (m, 2H), 5.97 (s, 2H), 4.09 – 4.05 (m, 2H), 3.92 (s, 4H), 3.74 –

3.71 (m, 2H), 3.66 (t, J = 6.0 Hz, 4H), 3.55 (t, J = 6.0 Hz, 4H), 3.40 (s, 3H), 2.54 (s, 6H),

13 1.49 – 1.45 (m, 24H). C NMR (101 MHz, CDCl3): δ (ppm) 169.76, 155.35, 152.79,

143.22, 142.04, 140.48, 131.82, 128.32, 121.76, 121.17, 121.06, 113.59, 81.62, 71.15,

119

69.91, 69.07, 68.21, 59.13, 52.52, 28.25, 14.71, 14.50. HRMS (ESI, m/z): calcd for

+ C38H54N3O8BF2 ([M+H] ) 729.4081; found 729.4089.

Synthesis of CaS. A solution of compound 62 (0.37 g, 0.5 mmol) in 5 mL solvent mixture TFA/CH2Cl2 (1:3) was stirred for 1 h at room temperature. Then the reaction mixture was condensed to remove solvents under vacuum. The residue was purified by flash column chromatography using CH2Cl2/methanol (5/1) as the eluent to give CaS as

1 red gum (0.039 g, 13%). H NMR (400 MHz, CD3CN): δ (ppm) 7.39 (d, J = 8.0 Hz, 1H),

7.02 (d, J = 1.8 Hz, 1H), 6.91 (dd, J = 8.0, 1.8 Hz, 1H), 6.10 (s, 2H), 4.14 (dd, J = 5.4,

3.7 Hz, 2H), 3.99 (s, 4H), 3.69 – 3.67 (m, 2H), 3.59 – 3.53 (m, 8H), 3.32 (s, 3H), 2.48 (s,

13 6H), 1.49 (s, 6H). C NMR (101 MHz, CD3CN): δ (ppm) 173.78, 156.52, 154.63, 144.52,

142.24, 134.07, 132.11, 126.10, 122.35, 121.77, 118.37, 114.57, 71.33, 69.29, 69.04,

+ 68.29, 59.01, 54.65, 14.75, 14.66. HRMS (ESI, m/z): calcd for C30H38N3O8BF2 ([M+H] )

617.2829; found 617.2831.

120

CHAPTER VI: FUTURE WORK

The investigation of some of the sensors, such as KS2 and CaS, can be continued in more depth. Considering their advantageous behavior in sensing their respective metal cations, additional investigations may be warranted.

VI.1 Potassium sensor KS2

For KS2, its selectivity towards probing potassium over other biological metal cations has been proven to be high. The fluorescence emission titration experiments indicate that it also has good sensitivity in sensing potassium. Moreover, it is insensitive to physiological pHs. Also, it has desirable two-photon absorption cross section.

Combining all the merits that KS2 has in sensing potassium, it is highly potential to be a two-photon absorption, red-emitting, fluorescence turn-on sensor for physiological potassium determination.

The toxicity of KS2 in cells should be evaluated. After that, cells will be incubated with KS2 and cell images will be taken at different concentrations of cellular potassium.

Both one-photon and two-photon excitation microscopy will be used to image cells.

VI.2 Calcium sensor CaS

For CaS, the following study will also be focused on biological applications.

Similar to the future plan for KS2, the toxicity of CaS will first be examined. Given that

CaS is a carboxylic salt, it should be difficult for it to pass through cell membranes.

121

Considering the potency that CaS has already exhibited for sensing calcium in extracellular environments, fluorescence emission microscopy will be used to determine extracellular levels of calcium. CaS may also be used to image calcium in tissues.

122

APPENDIX A: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER II

123

1 Figure A1. H NMR spectrum (400 MHz) of 21 in CDCl3.

124

13 Figure A2. C NMR spectrum (101 MHz) of 21 in CDCl3.

125

1 Figure A3. H NMR spectrum (400 MHz) of 22 in CDCl3.

126

13 Figure A4. C NMR spectrum (101 MHz) of 22 in CDCl3.

127

1 Figure A5. H NMR spectrum (400 MHz) of 23 in CDCl3.

128

13 Figure A6. C NMR spectrum (101 MHz) of 23 in CDCl3.

129

1 Figure A7. H NMR spectrum (400 MHz) of 24 in CDCl3.

130

13 Figure A8. C NMR spectrum (101 MHz) of 24 in CDCl3.

131

1 Figure A9. H NMR spectrum (400 MHz) of 27 in CDCl3.

132

13 Figure A10. C NMR spectrum (101 MHz) of 27 in CDCl3.

133

1 Figure A11. H NMR spectrum (400 MHz) of 28 in CDCl3.

134

13 Figure A12. C NMR spectrum (101 MHz) of 28 in CDCl3.

135

1 Figure A13. H NMR spectrum (400 MHz) of 29 in CDCl3.

136

13 Figure A14. C NMR spectrum (101 MHz) of 29 in CDCl3.

137

1 Figure A15. H NMR spectrum (400 MHz) of FS in CDCl3.

138

1 Figure A16. H NMR spectrum (400 MHz) of FS in DMSO-d6.

139

13 Figure A17. C NMR spectrum (101 MHz) of FS in CDCl3.

140

APPENDIX B: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER III

141

1 Figure B1. H NMR spectrum (400 MHz) of KS1 in CDCl3.

142

13 Figure B2. C NMR spectrum (101 MHz) of KS1 in CDCl3.

143

1 Figure B3. H NMR spectrum (400 MHz) of 42 in CDCl3.

144

13 Figure B4. C NMR spectrum (101 MHz) of 42 in CDCl3.

145

1 Figure B5. H NMR spectrum (400 MHz) of 43 in CDCl3.

146

13 Figure B6. C NMR spectrum (101 MHz) of 43 in CDCl3.

147

1 Figure B7. H NMR spectrum (400 MHz) of 44 in CDCl3.

148

13 Figure B8. C NMR spectrum (101 MHz) of 44 in CDCl3.

149

1 Figure B9. H NMR spectrum (400 MHz) of 45 in CDCl3.

150

13 Figure B10. C NMR spectrum (101 MHz) of 45 in CDCl3.

151

1 Figure B11. H NMR spectrum (400 MHz) of 46 in CDCl3.

152

13 Figure B12. C NMR spectrum (101 MHz) of 46 in CDCl3.

153

1 Figure B13. H NMR spectrum (400 MHz) of KS2 in CD2Cl2.

154

13 Figure B14. C NMR spectrum (101 MHz) of KS2 in CD2Cl2.

155

APPENDIX C: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER IV

156

1 Figure C1. H NMR spectrum (400 MHz) of 51 in CDCl3.

157

13 Figure C2. C NMR spectrum (101 MHz) of 51 in CDCl3.

158

1 Figure C3. H NMR spectrum (400 MHz) of 52 in CDCl3.

159

13 Figure C4. C NMR spectrum (101 MHz) of 52 in CDCl3.

160

1 Figure C5. H NMR spectrum (400 MHz) of 53 in CDCl3.

161

13 Figure C6. C NMR spectrum (101 MHz) of 53 in CDCl3.

162

1 Figure C7. H NMR spectrum (400 MHz) of 54 in CDCl3.

163

13 Figure C8. C NMR spectrum (101 MHz) of 54 in CDCl3.

164

1 Figure C9. H NMR spectrum (400 MHz) of 55 in CDCl3.

165

13 Figure C10. C NMR spectrum (101 MHz) of 55 in CDCl3.

166

1 Figure C11. H NMR spectrum (400 MHz) of FeS in CDCl3.

167

13 Figure C12. C NMR spectrum (101 MHz) of FeS in CDCl3.

168

APPENDIX D: 1H AND 13C NMR SPECTRA OF NEW COMPOUNDS IN CHAPTER V

169

1 Figure D1. H NMR spectrum (400 MHz) of 60 in CDCl3.

170

13 Figure D2. C NMR spectrum (101 MHz) of 60 in CDCl3.

171

1 Figure D3. H NMR spectrum (400 MHz) of 61 in CDCl3.

172

13 Figure D4. C NMR spectrum (101 MHz) of 61 in CDCl3.

173

1 Figure D5. H NMR spectrum (400 MHz) of 62 in CDCl3.

174

13 Figure D6. C NMR spectrum (101 MHz) of 62 in CDCl3.

175

1 Figure D7. H NMR spectrum (400 MHz) of CaS in CD3CN.

176

13 Figure D8. C NMR spectrum (101 MHz) of CaS in CD3CN.

177

APPENDIX E: COPYRIGHT PERMISSIONS

178

179

LIST OF REFERENCES

(1) Acuña, A. U.; Amat-Guerri, F. In Fluorescence of Supermolecules, , and Nanosystems; Berberan-Santos, M. N., Ed.; Springer Berlin Heidelberg: 2008; Vol. 4, p 3-20.

(2) Acuña, A. U.; Amat-Guerri, F.; Morcillo, P.; Liras, M.; Rodríguez, B. Structure and Formation of the Fluorescent Compound of Lignum Nephriticum. Organic Letters 2009, 11, 3020-3023.

(3) Muyskens, M.; Ed, V. The Fluorescence of Lignum Nephriticum: A Flash Back to the Past and a Simple Demonstration of Natural Substance Fluorescence. Journal of Chemical Education 2006, 83, 765.

(4) Valeur, B.; Berberan-Santos, M. r. N. A Brief History of Fluorescence and Phosphorescence before the Emergence of Quantum Theory. Journal of Chemical Education 2011, 88, 731-738.

(5) Herschel, J. F. W. On a Case of Superficial Colour Presented by a Homogeneous Liquid Internally Colourless. Philosophical Transactions of the Royal Society of London 1845, 135, 143-145.

(6) Herschel, J. F. W. On the Epipolic Dispersion of Light, Being a Supplement to a Paper Entitled, "on a Case of Superficial Colour Presented by a Homogeneous Liquid Internally Colourless". Philosophical Transactions of the Royal Society of London 1845, 135, 147-153.

(7) Stokes, G. G. On the Change of Refrangibility of Light. Philosophical Transactions of the Royal Society of London 1852, 142, 463-562.

(8) Jabłoński, A. Über Den Mechanismus Der Photolumineszenz Von Farbstoffphosphoren. Z. Physik 1935, 94, 38-46.

(9) Zipfel, W. R.; Williams, R. M.; Webb, W. W. Nonlinear Magic: Multiphoton Microscopy in the Biosciences. Nat Biotech 2003, 21, 1369-1377.

(10) Ciceron O. Yanez; Alma R. Morales; Xiling Yue; Takeo Urakami; Masanobu Komatsu; Tero A. H. Järvinen; Belfield, K. D. Deep Vascular Imaging in Wounds by Two-Photon Fluorescence Microscopy. PLoS ONE 2013, 8, e67559.

(11) de Silva, A. P.; Fox, D. B.; Moody, T. S.; Weir, S. M. The Development of Molecular Fluorescent Switches. Trends in Biotechnology, 19, 29-34.

180

(12) Rich, R. L.; Myszka, D. G. Survey of the Year 2001 Commercial Optical Literature. Journal of 2002, 15, 352-376.

(13) Cammann, K. Sensors and Analytical Chemistry Sensitivity Versus Quality. Physical Chemistry Chemical Physics 2003, 5, 5159-5168.

(14) Badugu, R. Fluorescence Sensor Design for Transition Metal Ions: The Role of the Piet Interaction Efficiency. J Fluoresc 2005, 15, 71-83.

(15) Wang, X.-D.; Wolfbeis, O. S. Fiber-Optic Chemical Sensors and (2008– 2012). Analytical Chemistry 2012, 85, 487-508.

(16) de Silva, A. P.; Gunaratne, H. Q. N.; Gunnlaugsson, T.; Huxley, A. J. M.; McCoy, C. P.; Rademacher, J. T.; Rice, T. E. Signaling Recognition Events with Fluorescent Sensors and Switches. Chemical Reviews 1997, 97, 1515-1566.

(17) Nolan, E. M.; Lippard, S. J. Tools and Tactics for the Optical Detection of Mercuric Ion. Chemical Reviews 2008, 108, 3443-3480.

(18) Duke, R. M.; Veale, E. B.; Pfeffer, F. M.; Kruger, P. E.; Gunnlaugsson, T. Colorimetric and Fluorescent Anion Sensors: An Overview of Recent Developments in the Use of 1,8-Naphthalimide-Based Chemosensors. Chemical Society Reviews 2010, 39, 3936-3953.

(19) Chen, X.; Pradhan, T.; Wang, F.; Kim, J. S.; Yoon, J. Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives. Chemical Reviews 2011, 112, 1910-1956.

(20) Hargrove, A. E.; Nieto, S.; Zhang, T.; Sessler, J. L.; Anslyn, E. V. Artificial Receptors for the Recognition of Phosphorylated Molecules. Chemical Reviews 2011, 111, 6603-6782.

(21) Boens, N.; Leen, V.; Dehaen, W. Fluorescent Indicators Based on Bodipy. Chemical Society Reviews 2012, 41, 1130-1172.

(22) Li, X.; Gao, X.; Shi, W.; Ma, H. Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes. Chemical Reviews 2013, 114, 590-659.

(23) Shi, W.; Ma, H. Spectroscopic Probes with Changeable [π]-Conjugated Systems. Chemical Communications 2012, 48, 8732-8744.

(24) Pedersen, C. J. Cyclic Polyethers and Their Complexes with Metal Salts. Journal of the American Chemical Society 1967, 89, 7017-7036.

181

(25) Cram, D. The Design of Molecular Hosts, Guests, and Their Complexes. Science 1988, 240, 760-767.

(26) Pedersen, C. J. The Discovery of Crown Ethers. Science 1988, 241, 536-540.

(27) Tsien, R. Y. A Non-Disruptive Technique for Loading Calcium Buffers and Indicators into Cells. Nature 1981, 290, 527-528.

(28) Minta, A.; Kao, J. P.; Tsien, R. Y. Fluorescent Indicators for Cytosolic Calcium Based on Rhodamine and Fluorescein Chromophores. Journal of Biological Chemistry 1989, 264, 8171-8178.

(29) Minta, A.; Tsien, R. Y. Fluorescent Indicators for Cytosolic Sodium. Journal of Biological Chemistry 1989, 264, 19449-19457.

(30) de Silva, A. P.; Gunaratne, H. Q. N.; Gunnlaugsson, T.; Nieuwenhuizen, M. Fluorescent Switches with High Selectivity Towards Sodium Ions: Correlation of Ion-Induced Conformation Switching with Fluorescence Function. Chemical Communications 1996, 1967-1968.

(31) Miyawaki, A.; Llopis, J.; Heim, R.; McCaffery, J. M.; Adams, J. A.; Ikura, M.; Tsien, R. Y. Fluorescent Indicators for Ca2+Based on Green Fluorescent Proteins and Calmodulin. Nature 1997, 388, 882-887.

(32) He, H.; Mortellaro, M. A.; Leiner, M. J. P.; Young, S. T.; Fraatz, R. J.; Tusa, J. K. A Fluorescent Chemosensor for Sodium Based on Photoinduced Electron Transfer. Analytical Chemistry 2002, 75, 549-555.

(33) He, H.; Mortellaro, M. A.; Leiner, M. J. P.; Fraatz, R. J.; Tusa, J. K. A Fluorescent Sensor with High Selectivity and Sensitivity for Potassium in Water. Journal of the American Chemical Society 2003, 125, 1468-1469.

(34) Harootunian, A. T.; Kao, J. P.; Eckert, B. K.; Tsien, R. Y. Fluorescence Ratio Imaging of Cytosolic Free Na+ in Individual Fibroblasts and Lymphocytes. Journal of Biological Chemistry 1989, 264, 19458-19467.

(35) Kaur, N.; Singh, N.; Cairns, D.; Callan, J. F. A Multifunctional Tripodal Fluorescent Probe: “Off−on” Detection of Sodium as Well as Two-Input and Molecular Logic Behavior. Organic Letters 2009, 11, 2229-2232.

(36) Padmawar, P.; Yao, X.; Bloch, O.; Manley, G. T.; Verkman, A. S. K+ Waves in Brain Cortex Visualized Using a Long-Wavelength K+-Sensing Fluorescent Indicator. Nat Meth 2005, 2, 825-827.

182

(37) Namkung, W.; Padmawar, P.; Mills, A. D.; Verkman, A. S. Cell-Based Fluorescence Screen for K+ Channels and Transporters Using an Extracellular Triazacryptand-Based K+ Sensor. Journal of the American Chemical Society 2008, 130, 7794-7795.

(38) Hirata, T.; Terai, T.; Komatsu, T.; Hanaoka, K.; Nagano, T. Development of a Potassium Ion-Selective Fluorescent Sensor Based on 3-Styrylated Bodipy. Bioorganic & Medicinal Chemistry Letters 2011, 21, 6090-6093.

(39) Zhou, X.; Su, F.; Gao, W.; Tian, Y.; Youngbull, C.; Johnson, R. H.; Meldrum, D. R. Triazacryptand-Based Fluorescent Sensors for Extracellular and Intracellular K+ Sensing. Biomaterials 2011, 32, 8574-8583.

(40) Zhou, X.; Su, F.; Tian, Y.; Youngbull, C.; Johnson, R. H.; Meldrum, D. R. A New Highly Selective Fluorescent K+ Sensor. Journal of the American Chemical Society 2011, 133, 18530-18533.

(41) Rusakov, D. A.; Fine, A. Extracellular Ca2+ Depletion Contributes to Fast Activity- Dependent Modulation of Synaptic Transmission in the Brain. Neuron, 37, 287-297.

(42) Suzuki, Y.; Komatsu, H.; Ikeda, T.; Saito, N.; Araki, S.; Citterio, D.; Hisamoto, H.; Kitamura, Y.; Kubota, T.; Nakagawa, J.; Oka, K.; Suzuki, K. Design and Synthesis of Mg2+-Selective Fluoroionophores Based on a Coumarin Derivative and Application for Mg2+ Measurement in a Living Cell. Analytical Chemistry 2002, 74, 1423-1428.

(43) Csordás, G.; Hajnóczky, G. Plasticity of Mitochondrial Calcium Signaling. Journal of Biological Chemistry 2003, 278, 42273-42282.

(44) Leite, M. F.; Thrower, E. C.; Echevarria, W.; Koulen, P.; Hirata, K.; Bennett, A. M.; Ehrlich, B. E.; Nathanson, M. H. Nuclear and Cytosolic Calcium Are Regulated Independently. Proceedings of the National Academy of Sciences 2003, 100, 2975-2980.

(45) Bronson, R. T.; Montalti, M.; Prodi, L.; Zaccheroni, N.; Lamb, R. D.; Dalley, N. K.; Izatt, R. M.; Bradshaw, J. S.; Savage, P. B. Origins of ‘On–Off’ Fluorescent Behavior of 8-Hydroxyquinoline Containing Chemosensors. Tetrahedron 2004, 60, 11139-11144.

(46) Komatsu, H.; Iwasawa, N.; Citterio, D.; Suzuki, Y.; Kubota, T.; Tokuno, K.; Kitamura, Y.; Oka, K.; Suzuki, K. Design and Synthesis of Highly Sensitive and Selective Fluorescein-Derived Magnesium Fluorescent Probes and Application to Intracellular 3d Mg2+ Imaging. Journal of the American Chemical Society 2004, 126, 16353-16360.

183

(47) Behanna, H. A.; Stupp, S. I. Synthesis of Stilbene Carboxylic Acids as Scaffolds for Calcium Sensors. Chemical Communications 2005, 4845-4847.

(48) Farruggia, G.; Iotti, S.; Prodi, L.; Montalti, M.; Zaccheroni, N.; Savage, P. B.; Trapani, V.; Sale, P.; Wolf, F. I. 8-Hydroxyquinoline Derivatives as Fluorescent Sensors for Magnesium in Living Cells. Journal of the American Chemical Society 2005, 128, 344-350.

(49) Komatsu, H.; Miki, T.; Citterio, D.; Kubota, T.; Shindo, Y.; Kitamura, Y.; Oka, K.; Suzuki, K. Single Molecular Multianalyte (Ca2+, Mg2+) Fluorescent Probe and Applications to Bioimaging. Journal of the American Chemical Society 2005, 127, 10798-10799.

(50) Kubota, T.; Shindo, Y.; Tokuno, K.; Komatsu, H.; Ogawa, H.; Kudo, S.; Kitamura, Y.; Suzuki, K.; Oka, K. Mitochondria Are Intracellular Magnesium Stores: Investigation by Simultaneous Fluorescent Imagings in Pc12 Cells. Biochimica et Biophysica Acta (BBA) - Molecular Cell Research 2005, 1744, 19-28.

(51) Kim, H. M.; Jung, C.; Kim, B. R.; Jung, S.-Y.; Hong, J. H.; Ko, Y.-G.; Lee, K. J.; Cho, B. R. Environment-Sensitive Two-Photon Probe for Intracellular Free Magnesium Ions in Live Tissue. Angewandte Chemie International Edition 2007, 46, 3460- 3463.

(52) Kim, H. M.; Kim, B. R.; Hong, J. H.; Park, J.-S.; Lee, K. J.; Cho, B. R. A Two- Photon Fluorescent Probe for Calcium Waves in Living Tissue. Angewandte Chemie International Edition 2007, 46, 7445-7448.

(53) Kim, H. M.; Yang, P. R.; Seo, M. S.; Yi, J.-S.; Hong, J. H.; Jeon, S.-J.; Ko, Y.-G.; Lee, K. J.; Cho, B. R. Magnesium Ion Selective Two-Photon Fluorescent Probe Based on a Benzo[H]Chromene Derivative for in Vivo Imaging. The Journal of Organic Chemistry 2007, 72, 2088-2096.

(54) Jin, J.; Desai, B. N.; Navarro, B.; Donovan, A.; Andrews, N. C.; Clapham, D. E. Deletion of Trpm7 Disrupts Embryonic Development and Thymopoiesis without Altering Mg2+ Homeostasis. Science 2008, 322, 756-760.

(55) Kim, H. M.; Kim, B. R.; An, M. J.; Hong, J. H.; Lee, K. J.; Cho, B. R. Two-Photon Fluorescent Probes for Long-Term Imaging of Calcium Waves in Live Tissue. Chemistry – A European Journal 2008, 14, 2075-2083.

(56) Dong, X.; Yang, Y.; Sun, J.; Liu, Z.; Liu, B.-F. Two-Photon Excited Fluorescent Probes for Calcium Based on Internal Charge Transfer. Chemical Communications 2009, 3883-3885.

184

(57) Namkung, W.; Song, Y.; Mills, A. D.; Padmawar, P.; Finkbeiner, W. E.; Verkman, A. S. In Situ Measurement of Airway Surface Liquid [K+] Using a Ratioable K+- Sensitive Fluorescent Dye. Journal of Biological Chemistry 2009, 284, 15916- 15926.

(58) Zhou, H.; Clapham, D. E. Mammalian Magt1 and Tusc3 Are Required for Cellular Magnesium Uptake and Vertebrate Embryonic Development. Proceedings of the National Academy of Sciences 2009, 106, 15750-15755.

(59) Kamiya, M.; Johnsson, K. Localizable and Highly Sensitive Calcium Indicator Based on a Bodipy Fluorophore. Analytical Chemistry 2010, 82, 6472-6479.

(60) Egawa, T.; Hanaoka, K.; Koide, Y.; Ujita, S.; Takahashi, N.; Ikegaya, Y.; Matsuki, N.; Terai, T.; Ueno, T.; Komatsu, T.; Nagano, T. Development of a Far-Red to near-Infrared Fluorescence Probe for Calcium Ion and Its Application to Multicolor Neuronal Imaging. Journal of the American Chemical Society 2011, 133, 14157- 14159.

(61) Matsui, A.; Umezawa, K.; Shindo, Y.; Fujii, T.; Citterio, D.; Oka, K.; Suzuki, K. A near-Infrared Fluorescent Calcium Probe: A New Tool for Intracellular Multicolour Ca2+ Imaging. Chemical Communications 2011, 47, 10407-10409.

(62) Marraccini, C.; Farruggia, G.; Lombardo, M.; Prodi, L.; Sgarzi, M.; Trapani, V.; Trombini, C.; Wolf, F. I.; Zaccheroni, N.; Iotti, S. Diaza-18-Crown-6 Hydroxyquinoline Derivatives as Flexible Tools for the Assessment and Imaging of Total Intracellular Magnesium. Chemical Science 2012, 3, 727-734.

(63) Liu, Q.; Bian, W.; Shi, H.; Fan, L.; Shuang, S.; Dong, C.; Choi, M. M. F. A Novel Ratiometric Emission Probe for Ca2+ in Living Cells. Organic & Biomolecular Chemistry 2013, 11, 503-508.

(64) Mao, J.; Wang, L.; Dou, W.; Tang, X.; Yan, Y.; Liu, W. Tuning the Selectivity of Two Chemosensors to Fe(III) and Cr(III). Organic Letters 2007, 9, 4567-4570.

(65) Huang, K.; Yang, H.; Zhou, Z.; Yu, M.; Li, F.; Gao, X.; Yi, T.; Huang, C. Multisignal Chemosensor for Cr3+ and Its Application in Bioimaging. Organic Letters 2008, 10, 2557-2560.

(66) Zhou, Z.; Yu, M.; Yang, H.; Huang, K.; Li, F.; Yi, T.; Huang, C. Fret-Based Sensor for Imaging Chromium(III) in Living Cells. Chemical Communications 2008, 3387- 3389.

(67) Xiang, Y.; Tong, A. A New Rhodamine-Based Chemosensor Exhibiting Selective FeIII-Amplified Fluorescence. Organic Letters 2006, 8, 1549-1552.

185

(68) Bae, S.; Tae, J. Rhodamine-Hydroxamate-Based Fluorescent Chemosensor for FeIII. Tetrahedron Letters 2007, 48, 5389-5392.

(69) Moon, K.-S.; Yang, Y.-K.; Ji, S.; Tae, J. Aminoxy-Linked Rhodamine Hydroxamate as Fluorescent Chemosensor for Fe3+ in Aqueous Media. Tetrahedron Letters 2010, 51, 3290-3293.

(70) Dong, L.; ChongWu; Zeng, X.; Mu, L.; Xue, S.-F.; Tao, Z.; Zhang, J.-X. The Synthesis of a Rhodamine B Schiff-Base Chemosensor and Recognition Properties for Fe3+ in Neutral Ethanol Aqueous Solution. Sensors and Actuators B: Chemical 2010, 145, 433-437.

(71) Weerasinghe, A. J.; Schmiesing, C.; Varaganti, S.; Ramakrishna, G.; Sinn, E. Single- and Multiphoton Turn-on Fluorescent Fe3+ Sensors Based on Bis(Rhodamine). The Journal of Physical Chemistry B 2010, 114, 9413-9419.

(72) Chartres, J. D.; Busby, M.; Riley, M. J.; Davis, J. J.; Bernhardt, P. V. A Turn-on Fluorescent Iron Complex and Its Cellular Uptake. Inorganic Chemistry 2011, 50, 9178-9183.

(73) Chen, W.; Shi, W.; Li, Z.; Ma, H.; Liu, Y.; Zhang, J.; Liu, Q. Simple and Fast Fluorescence Detection of Benzoyl Peroxide in Wheat Flour by N-Methoxy Rhodamine-6g Spirolactam Based on Consecutive Chemical Reactions. Analytica Chimica Acta 2011, 708, 84-88.

(74) Yang, Z.; She, M.; Yin, B.; Cui, J.; Zhang, Y.; Sun, W.; Li, J.; Shi, Z. Three Rhodamine-Based “Off–On” Chemosensors with High Selectivity and Sensitivity for Fe3+ Imaging in Living Cells. The Journal of Organic Chemistry 2011, 77, 1143-1147.

(75) Huang, L.; Hou, F.; Cheng, J.; Xi, P.; Chen, F.; Bai, D.; Zeng, Z. Selective Off-On Fluorescent Chemosensor for Detection of Fe3+ Ions in Aqueous Media. Organic & Biomolecular Chemistry 2012, 10, 9634-9638.

(76) Maity, D.; Govindaraju, T. Highly Selective Colorimetric Chemosensor for Co2+. Inorganic Chemistry 2011, 50, 11282-11284.

(77) Zhen, S. J.; Guo, F. L.; Chen, L. Q.; Li, Y. F.; Zhang, Q.; Huang, C. Z. Visual Detection of Cobalt(II) Ion in Vitro and Tissue with a New Type of Leaf-Like Molecular Microcrystal. Chemical Communications 2011, 47, 2562-2564.

(78) Shiraishi, Y.; Matsunaga, Y.; Hirai, T. Selective Colorimetric Sensing of Co(II) in Aqueous Media with a Spiropyran-Amide-Dipicolylamine Linkage under UV Irradiation. Chemical Communications 2012, 48, 5485-5487.

186

(79) Dodani, S. C.; He, Q.; Chang, C. J. A Turn-on Fluorescent Sensor for Detecting Nickel in Living Cells. Journal of the American Chemical Society 2009, 131, 18020-18021.

(80) Banerjee, A.; Sahana, A.; Guha, S.; Lohar, S.; Hauli, I.; Mukhopadhyay, S. K.; Sanmartín Matalobos, J.; Das, D. Nickel(II)-Induced Formation of a Naphthalene-Based Fluorescent Probe for Living Cell Imaging. Inorganic Chemistry 2012, 51, 5699-5704.

(81) Kang, M. Y.; Lim, C. S.; Kim, H. S.; Seo, E. W.; Kim, H. M.; Kwon, O.; Cho, B. R. Detection of Nickel in Fish Organs with a Two-Photon Fluorescent Probe. Chemistry – A European Journal 2012, 18, 1953-1960.

(82) Royzen, M.; Dai, Z.; Canary, J. W. Ratiometric Displacement Approach to Cu(II) Sensing by Fluorescence. Journal of the American Chemical Society 2005, 127, 1612-1613.

(83) Xiang, Y.; Tong, A.; Jin, P.; Ju, Y. New Fluorescent Rhodamine Hydrazone Chemosensor for Cu(II) with High Selectivity and Sensitivity. Organic Letters 2006, 8, 2863-2866.

(84) Kim, H. J.; Hong, J.; Hong, A.; Ham, S.; Lee, J. H.; Kim, J. S. Cu2+-Induced Intermolecular Static Excimer Formation of Pyrenealkylamine. Organic Letters 2008, 10, 1963-1966.

(85) Ballesteros, E.; Moreno, D.; Gómez, T.; Rodríguez, T.; Rojo, J.; García-Valverde, M.; Torroba, T. A New Selective Chromogenic and Turn-on Fluorogenic Probe for Copper(II) in Water−Acetonitrile 1:1 Solution. Organic Letters 2009, 11, 1269-1272.

(86) Zhao, Y.; Zhang, X.-B.; Han, Z.-X.; Qiao, L.; Li, C.-Y.; Jian, L.-X.; Shen, G.-L.; Yu, R.-Q. Highly Sensitive and Selective Colorimetric and Off−On Fluorescent Chemosensor for Cu2+ in Aqueous Solution and Living Cells. Analytical Chemistry 2009, 81, 7022-7030.

(87) Goswami, S.; Sen, D.; Das, N. K. A New Highly Selective, Ratiometric and Colorimetric Fluorescence Sensor for Cu2+ with a Remarkable Red Shift in Absorption and Emission Spectra Based on Internal Charge Transfer. Organic Letters 2010, 12, 856-859.

(88) Zhang, J. F.; Zhou, Y.; Yoon, J.; Kim, Y.; Kim, S. J.; Kim, J. S. Naphthalimide Modified Rhodamine Derivative: Ratiometric and Selective Fluorescent Sensor for Cu2+ Based on Two Different Approaches. Organic Letters 2010, 12, 3852-3855.

187

(89) Chen, X.; Wang, J.; Cui, J.; Xu, Z.; Peng, X. A Ratiometric and Exclusively Selective CuII Fluorescent Probe Based on Internal Charge Transfer (ICT). Tetrahedron 2011, 67, 4869-4873.

(90) Li, P.; Duan, X.; Chen, Z.; Liu, Y.; Xie, T.; Fang, L.; Li, X.; Yin, M.; Tang, B. A near- Infrared Fluorescent Probe for Detecting Copper(II) with High Selectivity and Sensitivity and Its Biological Imaging Applications. Chemical Communications 2011, 47, 7755-7757.

(91) You, Y.; Han, Y.; Lee, Y.-M.; Park, S. Y.; Nam, W.; Lippard, S. J. Phosphorescent Sensor for Robust Quantification of Copper(II) Ion. Journal of the American Chemical Society 2011, 133, 11488-11491.

(92) Liu, Z.; Zhang, C.; Wang, X.; He, W.; Guo, Z. Design and Synthesis of a Ratiometric Fluorescent Chemosensor for Cu(II) with a Fluorophore Hybridization Approach. Organic Letters 2012, 14, 4378-4381.

(93) Atilgan, S.; Ozdemir, T.; Akkaya, E. U. A Sensitive and Selective Ratiometric near Ir Fluorescent Probe for Zinc Ions Based on the Distyryl−Bodipy Fluorophore. Organic Letters 2008, 10, 4065-4067.

(94) Sivaraman, G.; Anand, T.; Chellappa, D. Turn-on Fluorescent Chemosensor for Zn(II) Via Ring Opening of Rhodamine Spirolactam and Their Live Cell Imaging. Analyst 2012, 137, 5881-5884.

(95) Sasaki, H.; Hanaoka, K.; Urano, Y.; Terai, T.; Nagano, T. Design and Synthesis of a Novel Fluorescence Probe for Zn2+ Based on the Spirolactam Ring-Opening Process of Rhodamine Derivatives. Bioorganic & Medicinal Chemistry 2011, 19, 1072-1078.

(96) Zhou, Y.; Li, Z.-X.; Zang, S.-Q.; Zhu, Y.-Y.; Zhang, H.-Y.; Hou, H.-W.; Mak, T. C. W. A Novel Sensitive Turn-On Fluorescent Zn2+ Chemosensor Based on an Easy to Prepare C3-Symmetric Schiff-Base Derivative in 100% Aqueous Solution. Organic Letters 2012, 14, 1214-1217.

(97) Zhang, Z.; Wang, F.-W.; Wang, S.-Q.; Ge, F.; Zhao, B.-X.; Miao, J.-Y. A Highly Sensitive Fluorescent Probe Based on Simple Pyrazoline for Zn2+ in Living Neuron Cells. Organic & Biomolecular Chemistry 2012, 10, 8640-8644.

(98) Li, N.; Xiang, Y.; Chen, X.; Tong, A. Salicylaldehyde Hydrazones as Fluorescent Probes for Zinc Ion in Aqueous Solution of Physiological Ph. Talanta 2009, 79, 327-332.

188

(99) Dhara, K.; Karan, S.; Ratha, J.; Roy, P.; Chandra, G.; Manassero, M.; Mallik, B.; Banerjee, P. A Two-Dimensional Coordination Compound as a Zinc Ion Selective Luminescent Probe for Biological Applications. Chemistry – An Asian Journal 2007, 2, 1091-1100.

(100) Felton, C. E.; Harding, L. P.; Jones, J. E.; Kariuki, B. M.; Pope, S. J. A.; Rice, C. R. A Wavelength and Lifetime Responsive Cryptate-Containing Fluorescent Probe for Zinc Ions in Water. Chemical Communications 2008, 6185-6187.

(101) Ajayaghosh, A.; Carol, P.; Sreejith, S. A Ratiometric Fluorescence Probe for Selective Visual Sensing of Zn2+. Journal of the American Chemical Society 2005, 127, 14962-14963.

(102) Tamanini, E.; Flavin, K.; Motevalli, M.; Piperno, S.; Gheber, L. A.; Todd, M. H.; Watkinson, M. Cyclam-Based “Clickates”: Homogeneous and Heterogeneous Fluorescent Sensors for Zn(II). Inorganic Chemistry 2010, 49, 3789-3800.

(103) Koike, T.; Kajitani, S.; Nakamura, I.; Kimura, E.; Shiro, M. The Catalytic Carboxyester Hydrolysis by a New Zinc(II) Complex with an Alcohol-Pendant Cyclen (1-(2-Hydroxyethyl)-1,4,7,10-Tetraazacyclododecane): A Novel Model for Indirect Activation of the Serine Nucleophile by Zinc(II) in Zinc Enzymes. Journal of the American Chemical Society 1995, 117, 1210-1219.

(104) Aoki, S.; Sakurama, K.; Matsuo, N.; Yamada, Y.; Takasawa, R.; Tanuma, S.-i.; Shiro, M.; Takeda, K.; Kimura, E. A New Fluorescent Probe for Zinc(II): An 8- Hydroxy-5-N,N-Dimethylaminosulfonylquinoline-Pendant 1,4,7,10-Tetraazacyclo- dodecane. Chemistry – A European Journal 2006, 12, 9066-9080.

(105) Carol, P.; Sreejith, S.; Ajayaghosh, A. Ratiometric and near-Infrared Molecular Probes for the Detection and Imaging of Zinc Ions. Chemistry – An Asian Journal 2007, 2, 338-348.

(106) Kimura, E.; Aoki, S.; Kikuta, E.; Koike, T. A Macrocyclic Zinc(II) Fluorophore as a Detector of Apoptosis. Proceedings of the National Academy of Sciences 2003, 100, 3731-3736.

(107) Sensi, S. L.; Ton-That, D.; Weiss, J. H.; Rothe, A.; Gee, K. R. A New Mitochondrial Fluorescent Zinc Sensor. Cell Calcium 2003, 34, 281-284.

(108) Gee, K. R.; Zhou, Z. L.; Ton-That, D.; Sensi, S. L.; Weiss, J. H. Measuring Zinc in Living Cells.: A New Generation of Sensitive and Selective Fluorescent Probes. Cell Calcium 2002, 31, 245-251.

189

(109) Comby, S.; Tuck, S. A.; Truman, L. K.; Kotova, O.; Gunnlaugsson, T. New Trick for an Old Ligand! The Sensing of Zn(II) Using a Lanthanide Based Ternary Yb(III)-Cyclen-8-Hydroxyquinoline System as a Dual Emissive Probe for Displacement Assay. Inorganic Chemistry 2012, 51, 10158-10168.

(110) Luo, J.; Li, W.-S.; Xu, P.; Zhang, L.-Y.; Chen, Z.-N. Zn2+ Responsive Bimodal Magnetic Resonance Imaging and Fluorescent Imaging Probe Based on a Gadolinium(III) Complex. Inorganic Chemistry 2012, 51, 9508-9516.

(111) McQuade, L. E.; Lippard, S. J. Cell-Trappable Quinoline-Derivatized Fluoresceins for Selective and Reversible Biological Zn(II) Detection. Inorganic Chemistry 2010, 49, 9535-9545.

(112) Nolan, E. M.; Jaworski, J.; Okamoto, K.-I.; Hayashi, Y.; Sheng, M.; Lippard, S. J. Qz1 and Qz2: Rapid, Reversible Quinoline-Derivatized Fluoresceins for Sensing Biological Zn(II). Journal of the American Chemical Society 2005, 127, 16812- 16823.

(113) Zhang, Y.; Guo, X.; Si, W.; Jia, L.; Qian, X. Ratiometric and Water-Soluble Fluorescent Zinc Sensor of Carboxamidoquinoline with an Alkoxyethylamino Chain as Receptor. Organic Letters 2008, 10, 473-476.

(114) Kimura, E.; Koike, T. Recent Development of Zinc-Fluorophores. Chemical Society Reviews 1998, 27, 179-184.

(115) Xue, L.; Li, G.; Yu, C.; Jiang, H. A Ratiometric and Targetable Fluorescent Sensor for Quantification of Mitochondrial Zinc Ions. Chemistry – A European Journal 2012, 18, 1050-1054.

(116) Masanta, G.; Lim, C. S.; Kim, H. J.; Han, J. H.; Kim, H. M.; Cho, B. R. A Mitochondrial-Targeted Two-Photon Probe for Zinc Ion. Journal of the American Chemical Society 2011, 133, 5698-5700.

(117) Kiyose, K.; Kojima, H.; Urano, Y.; Nagano, T. Development of a Ratiometric Fluorescent Zinc Ion Probe in near-Infrared Region, Based on Tricarbocyanine Chromophore. Journal of the American Chemical Society 2006, 128, 6548-6549.

(118) Guo, Z.; Kim, G.-H.; Shin, I.; Yoon, J. A Cyanine-Based Fluorescent Sensor for Detecting Endogenous Zinc Ions in Live Cells and Organisms. Biomaterials 2012, 33, 7818-7827.

(119) Tang, B.; Huang, H.; Xu, K.; Tong, L.; Yang, G.; Liu, X.; An, L. Highly Sensitive and Selective Near-Infrared Fluorescent Probe for Zinc and Its Application to Macrophage Cells. Chemical Communications 2006, 3609-3611.

190

(120) Qian, F.; Zhang, C.; Zhang, Y.; He, W.; Gao, X.; Hu, P.; Guo, Z. Visible Light Excitable Zn2+ Fluorescent Sensor Derived from an Intramolecular Charge Transfer Fluorophore and Its in Vitro and in Vivo Application. Journal of the American Chemical Society 2009, 131, 1460-1468.

(121) Koide, Y.; Urano, Y.; Hanaoka, K.; Terai, T.; Nagano, T. Evolution of Group 14 Rhodamines as Platforms for Near-Infrared Fluorescence Probes Utilizing Photoinduced Electron Transfer. ACS Chemical Biology 2011, 6, 600-608.

(122) Kwon, J. E.; Lee, S.; You, Y.; Baek, K.-H.; Ohkubo, K.; Cho, J.; Fukuzumi, S.; Shin, I.; Park, S. Y.; Nam, W. Fluorescent Zinc Sensor with Minimized Proton- Induced Interferences: Photophysical Mechanism for Fluorescence Turn-on Response and Detection of Endogenous Free Zinc Ions. Inorganic Chemistry 2012, 51, 8760-8774.

(123) Hirano, T.; Kikuchi, K.; Urano, Y.; Nagano, T. Improvement and Biological Applications of Fluorescent Probes for Zinc, Znafs. Journal of the American Chemical Society 2002, 124, 6555-6562.

(124) Chang, C. J.; Jaworski, J.; Nolan, E. M.; Sheng, M.; Lippard, S. J. A Tautomeric Zinc Sensor for Ratiometric Fluorescence Imaging: Application to Nitric Oxide- Induced Release of Intracellular Zinc. Proceedings of the National Academy of Sciences of the United States of America 2004, 101, 1129-1134.

(125) Woodroofe, C. C.; Lippard, S. J. A Novel Two-Fluorophore Approach to Ratiometric Sensing of Zn2+. Journal of the American Chemical Society 2003, 125, 11458-11459.

(126) Ghosh, S. K.; Kim, P.; Zhang, X.-a.; Yun, S.-H.; Moore, A.; Lippard, S. J.; Medarova, Z. A Novel Imaging Approach for Early Detection of Prostate Cancer Based on Endogenous Zinc Sensing. Cancer Research 2010, 70, 6119-6127.

(127) Buccella, D.; Horowitz, J. A.; Lippard, S. J. Understanding Zinc Quantification with Existing and Advanced Ditopic Fluorescent Zinpyr Sensors. Journal of the American Chemical Society 2011, 133, 4101-4114.

(128) Frederickson, C. J.; Burdette, S. C.; Frederickson, C. J.; Sensi, S. L.; Weiss, J. H.; Yin, H. Z.; Balaji, R. V.; Truong-Tran, A. Q.; Bedell, E.; Prough, D. S.; Lippard, S. J. Method for Identifying Neuronal Cells Suffering Zinc Toxicity by Use of a Novel Fluorescent Sensor. Journal of Neuroscience Methods 2004, 139, 79-89.

(129) Burdette, S. C.; Frederickson, C. J.; Bu, W.; Lippard, S. J. Zp4, an Improved Neuronal Zn2+ Sensor of the Zinpyr Family. Journal of the American Chemical Society 2003, 125, 1778-1787.

191

(130) You, Y.; Lee, S.; Kim, T.; Ohkubo, K.; Chae, W.-S.; Fukuzumi, S.; Jhon, G.-J.; Nam, W.; Lippard, S. J. Phosphorescent Sensor for Biological Mobile Zinc. Journal of the American Chemical Society 2011, 133, 18328-18342.

(131) Tomat, E.; Lippard, S. J. Ratiometric and Intensity-Based Zinc Sensors Built on Rhodol and Rhodamine Platforms. Inorganic Chemistry 2010, 49, 9113-9115.

(132) Wong, B. A.; Friedle, S.; Lippard, S. J. Solution and Fluorescence Properties of Symmetric Dipicolylamine-Containing Dichlorofluorescein-Based Zn2+ Sensors. Journal of the American Chemical Society 2009, 131, 7142-7152.

(133) Woodroofe, C. C.; Masalha, R.; Barnes, K. R.; Frederickson, C. J.; Lippard, S. J. Membrane-Permeable and -Impermeable Sensors of the Zinpyr Family and Their Application to Imaging of Hippocampal Zinc in Vivo. Chemistry & Biology 2004, 11, 1659-1666.

(134) Burdette, S. C.; Walkup, G. K.; Spingler, B.; Tsien, R. Y.; Lippard, S. J. Fluorescent Sensors for Zn2+ Based on a Fluorescein Platform: Synthesis, Properties and Intracellular Distribution. Journal of the American Chemical Society 2001, 123, 7831-7841.

(135) Du, P.; Lippard, S. J. A Highly Selective Turn-on Colorimetric, Red Fluorescent Sensor for Detecting Mobile Zinc in Living Cells. Inorganic Chemistry 2010, 49, 10753-10755.

(136) Kawabata, E.; Kikuchi, K.; Urano, Y.; Kojima, H.; Odani, A.; Nagano, T. Design and Synthesis of Zinc-Selective Chelators for Extracellular Applications. Journal of the American Chemical Society 2004, 127, 818-819.

(137) Xu, Z.; Kim, G.-H.; Han, S. J.; Jou, M. J.; Lee, C.; Shin, I.; Yoon, J. An Nbd-Based Colorimetric and Fluorescent Chemosensor for Zn2+ and Its Use for Detection of Intracellular Zinc Ions. Tetrahedron 2009, 65, 2307-2312.

(138) Sumalekshmy, S.; Henary, M. M.; Siegel, N.; Lawson, P. V.; Wu; Schmidt, K.; Brédas, J.-L.; Perry, J. W.; Fahrni, C. J. Design of Emission Ratiometric Metal-Ion Sensors with Enhanced Two-Photon Cross Section and Brightness. Journal of the American Chemical Society 2007, 129, 11888-11889.

(139) Jiang, W.; Fu, Q.; Fan, H.; Wang, W. An Nbd Fluorophore-Based Sensitive and Selective Fluorescent Probe for Zinc Ion. Chemical Communications 2008, 259- 261.

(140) Kim, H. M.; Seo, M. S.; An, M. J.; Hong, J. H.; Tian, Y. S.; Choi, J. H.; Kwon, O.; Lee, K. J.; Cho, B. R. Two-Photon Fluorescent Probes for Intracellular Free Zinc

192

Ions in Living Tissue. Angewandte Chemie International Edition 2008, 47, 5167- 5170.

(141) Henary, M. M.; Wu, Y.; Fahrni, C. J. Zinc(II)-Selective Ratiometric Fluorescent Sensors Based on Inhibition of Excited-State Intramolecular Proton Transfer. Chemistry – A European Journal 2004, 10, 3015-3025.

(142) Taki, M.; Wolford, J. L.; O'Halloran, T. V. Emission Ratiometric Imaging of Intracellular Zinc: Design of a Benzoxazole Fluorescent Sensor and Its Application in Two-Photon Microscopy. Journal of the American Chemical Society 2003, 126, 712-713.

(143) Maruyama, S.; Kikuchi, K.; Hirano, T.; Urano, Y.; Nagano, T. A Novel, Cell- Permeable, Fluorescent Probe for Ratiometric Imaging of Zinc Ion. Journal of the American Chemical Society 2002, 124, 10650-10651.

(144) Aoki, S.; Kagata, D.; Shiro, M.; Takeda, K.; Kimura, E. Metal Chelation-Controlled Twisted Intramolecular Charge Transfer and Its Application to Fluorescent Sensing of Metal Ions and Anions. Journal of the American Chemical Society 2004, 126, 13377-13390.

(145) Li, H.; Fan, J.; Du, J.; Guo, K.; Sun, S.; Liu, X.; Peng, X. A Fluorescent and Colorimetric Probe Specific for Palladium Detection. Chemical Communications 2010, 46, 1079-1081.

(146) Li, H.; Fan, J.; Song, F.; Zhu, H.; Du, J.; Sun, S.; Peng, X. Fluorescent Probes for Pd2+ Detection by Allylidene–Hydrazone Ligands with Excellent Selectivity and Large Fluorescence Enhancement. Chemistry – A European Journal 2010, 16, 12349-12356.

(147) Goswami, S.; Sen, D.; Das, N. K.; Fun, H.-K.; Quah, C. K. A New Rhodamine Based Colorimetric 'Off-On' Fluorescence Sensor Selective for Pd2+ Along with the First Bound X-Ray Crystal Structure. Chemical Communications 2011, 47, 9101-9103.

(148) Yang, R.-H.; Chan, W.-H.; Lee, A. W. M.; Xia, P.-F.; Zhang, H.-K. A Ratiometric Fluorescent Sensor for Agi with High Selectivity and Sensitivity. Journal of the American Chemical Society 2003, 125, 2884-2885.

(149) Schmittel, M.; Lin, H. Luminescent Iridium Phenanthroline Crown Ether Complex for the Detection of Silver(I) Ions in Aqueous Media. Inorganic Chemistry 2007, 46, 9139-9145.

193

(150) Bhardwaj, V. K.; Pannu, A. P. S.; Singh, N.; Hundal, M. S.; Hundal, G. Synthesis of New Tripodal Receptors—a ‘PET’ Based ‘Off–On’ Recognition of Ag+. Tetrahedron 2008, 64, 5384-5391.

(151) Huang, C.; Peng, X.; Lin, Z.; Fan, J.; Ren, A.; Sun, D. A Highly Selective and Sensitive Two-Photon Chemosensor for Silver Ion Derived from 3,9-Dithia-6- Azaundecane. Sensors and Actuators B: Chemical 2008, 133, 113-117.

(152) Iyoshi, S.; Taki, M.; Yamamoto, Y. Rosamine-Based Fluorescent Chemosensor for Selective Detection of Silver(I) in an Aqueous Solution. Inorganic Chemistry 2008, 47, 3946-3948.

(153) Park, C. S.; Lee, J. Y.; Kang, E.-J.; Lee, J.-E.; Lee, S. S. A Highly Selective Fluorescent Chemosensor for Silver(I) in Water/Ethanol Mixture. Tetrahedron Letters 2009, 50, 671-675.

(154) Pandey, M. D.; Mishra, A. K.; Chandrasekhar, V.; Verma, S. Silver-Guided Excimer Emission in an Adenine−Pyrene Conjugate: Fluorescence Lifetime and Crystal Studies. Inorganic Chemistry 2010, 49, 2020-2022.

(155) Sakamoto, H.; Ishikawa, J.; Osuga, H.; Doi, K.; Wada, H. Highly Silver Ion Selective Fluorescence Ionophore: Fluorescent Properties of Polythiazaalkane Derivatives Bearing 8-(7-Hydroxy-4-Methyl)Coumarinyl Moiety in Aqueous Solution and in Liquid-Liquid Extraction Systems. Analyst 2010, 135, 550-558.

(156) Xu, Z.; Zheng, S.; Yoon, J.; Spring, D. R. Discovery of a Highly Selective Turn-on Fluorescent Probe for Ag+. Analyst 2010, 135, 2554-2559.

(157) Huang, S.; He, S.; Lu, Y.; Wei, F.; Zeng, X.; Zhao, L. Highly Sensitive and Selective Fluorescent Chemosensor for Ag+ Based on a Coumarin-Se2n Chelating Conjugate. Chemical Communications 2011, 47, 2408-2410.

(158) Wang, F.; Nandhakumar, R.; Moon, J. H.; Kim, K. M.; Lee, J. Y.; Yoon, J. Ratiometric Fluorescent Chemosensor for Silver Ion at Physiological Ph. Inorganic Chemistry 2011, 50, 2240-2245.

(159) Zhang, J. F.; Zhou, Y.; Yoon, J.; Kim, J. S. Recent Progress in Fluorescent and Colorimetric Chemosensors for Detection of Precious Metal Ions (Silver, Gold and Platinum Ions). Chemical Society Reviews 2011, 40, 3416-3429.

(160) Jang, S.; Thirupathi, P.; Neupane, L. N.; Seong, J.; Lee, H.; Lee, W. I.; Lee, K.-H. Highly Sensitive Ratiometric Fluorescent Chemosensor for Silver Ion and Silver in Aqueous Solution. Organic Letters 2012, 14, 4746-4749.

194

(161) Zheng, H.; Yan, M.; Fan, X.-X.; Sun, D.; Yang, S.-Y.; Yang, L.-J.; Li, J.-D.; Jiang, Y.-B. A Heptamethine Cyanine-Based Colorimetric and Ratiometric Fluorescent Chemosensor for the Selective Detection of Ag+ in an Aqueous Medium. Chemical Communications 2012, 48, 2243-2245.

(162) Liu, Z.; Zhang, C.; He, W.; Yang, Z.; Gao, X.; Guo, Z. A Highly Sensitive Ratiometric Fluorescent Probe for Cd2+ Detection in Aqueous Solution and Living Cells. Chemical Communications 2010, 46, 6138-6140.

(163) Taki, M.; Desaki, M.; Ojida, A.; Iyoshi, S.; Hirayama, T.; Hamachi, I.; Yamamoto, Y. Fluorescence Imaging of Intracellular Cadmium Using a Dual-Excitation Ratiometric Chemosensor. Journal of the American Chemical Society 2008, 130, 12564-12565.

(164) Xue, L.; Li, G.; Liu, Q.; Wang, H.; Liu, C.; Ding, X.; He, S.; Jiang, H. Ratiometric Fluorescent Sensor Based on Inhibition of Resonance for Detection of Cadmium in Aqueous Solution and Living Cells. Inorganic Chemistry 2011, 50, 3680-3690.

(165) Xue, L.; Liu, C.; Jiang, H. Highly Sensitive and Selective Fluorescent Sensor for Distinguishing Cadmium from Zinc Ions in Aqueous Media. Organic Letters 2009, 11, 1655-1658.

(166) Lu, C.; Xu, Z.; Cui, J.; Zhang, R.; Qian, X. Ratiometric and Highly Selective Fluorescent Sensor for Cadmium under Physiological Ph Range: A New Strategy to Discriminate Cadmium from Zinc. The Journal of Organic Chemistry 2007, 72, 3554-3557.

(167) Jia, J.; Xu, Q.-C.; Li, R.-c.; Tang, X.; He, Y.-F.; Zhang, M.-Y.; Zhang, Y.; Xing, G.- W. Tetrahydroindazolone Substituted 2-Aminobenzamides as Fluorescent Probes: Switching Metal Ion Selectivity from Zinc to Cadmium by Interchanging the Amino and Carbamoyl Groups on the Fluorophore. Organic & Biomolecular Chemistry 2012, 10, 6279-6286.

(168) Yang, Y.; Cheng, T.; Zhu, W.; Xu, Y.; Qian, X. Highly Selective and Sensitive Near-Infrared Fluorescent Sensors for Cadmium in Aqueous Solution. Organic Letters 2010, 13, 264-267.

(169) Cheng, T.; Xu, Y.; Zhang, S.; Zhu, W.; Qian, X.; Duan, L. A Highly Sensitive and Selective Off-On Fluorescent Sensor for Cadmium in Aqueous Solution and Living Cell. Journal of the American Chemical Society 2008, 130, 16160-16161.

(170) Cheng, T.; Wang, T.; Zhu, W.; Yang, Y.; Zeng, B.; Xu, Y.; Qian, X. Modulating the Selectivity of Near-IR Fluorescent Probes toward Various Metal Ions by Judicious

195

Choice of Aqueous Buffer Solutions. Chemical Communications 2011, 47, 3915- 3917.

(171) Kim, H. N.; Ren, W. X.; Kim, J. S.; Yoon, J. Fluorescent and Colorimetric Sensors for Detection of Lead, Cadmium, and Mercury Ions. Chemical Society Reviews 2012, 41, 3210-3244.

(172) Bao, Y.; Liu, B.; Wang, H.; Du, F.; Bai, R. A Highly Sensitive and Selective Ratiometric Cd2+ Fluorescent Sensor for Distinguishing Cd2+ from Zn2+ Based on Both Fluorescence Intensity and Emission Shift. Analytical Methods 2011, 3, 1274-1276.

(173) Mameli, M.; Aragoni, M. C.; Arca, M.; Caltagirone, C.; Demartin, F.; Farruggia, G.; De Filippo, G.; Devillanova, F. A.; Garau, A.; Isaia, F.; Lippolis, V.; Murgia, S.; Prodi, L.; Pintus, A.; Zaccheroni, N. A Selective, Nontoxic, Off–On Fluorescent Molecular Sensor Based on 8-Hydroxyquinoline for Probing Cd2+ in Living Cells. Chemistry – A European Journal 2010, 16, 919-930.

(174) Liu, W.; Xu, L.; Sheng, R.; Wang, P.; Li, H.; Wu, S. A Water-Soluble “Switching On” Fluorescent Chemosensor of Selectivity to Cd2+. Organic Letters 2007, 9, 3829-3832.

(175) Gunnlaugsson, T.; Lee, T. C.; Parkesh, R. Cd(II) Sensing in Water Using Novel Aromatic Iminodiacetate Based Fluorescent Chemosensors. Organic Letters 2003, 5, 4065-4068.

(176) Peng, X.; Du, J.; Fan, J.; Wang, J.; Wu, Y.; Zhao, J.; Sun, S.; Xu, T. A Selective Fluorescent Sensor for Imaging Cd2+ in Living Cells. Journal of the American Chemical Society 2007, 129, 1500-1501.

(177) Zheng, H.; Zhang, X.-J.; Cai, X.; Bian, Q.-N.; Yan, M.; Wu, G.-H.; Lai, X.-W.; Jiang, Y.-B. Ratiometric Fluorescent Chemosensor for Hg2+ Based on Heptamethine Cyanine Containing a Thymine Moiety. Organic Letters 2012, 14, 1986-1989.

(178) Ono, A.; Togashi, H. Highly Selective Oligonucleotide-Based Sensor for Mercury(II) in Aqueous Solutions. Angewandte Chemie International Edition 2004, 43, 4300-4302.

(179) Neupane, L. N.; Kim, J. M.; Lohani, C. R.; Lee, K.-H. Selective and Sensitive Ratiometric Detection of Hg2+ in 100% Aqueous Solution with Triazole-Based Dansyl Probe. Journal of Materials Chemistry 2012, 22, 4003-4008.

196

(180) Chen, L.; Yang, L.; Li, H.; Gao, Y.; Deng, D.; Wu, Y.; Ma, L.-j. Tridentate Lysine- Based Fluorescent Sensor for Hg(II) in Aqueous Solution. Inorganic Chemistry 2011, 50, 10028-10032.

(181) Wang, J.; Qian, X. A Series of Polyamide Receptor Based Pet Fluorescent Sensor Molecules: Positively Cooperative Hg2+ Ion Binding with High Sensitivity. Organic Letters 2006, 8, 3721-3724.

(182) Wang, J.; Qian, X. Two Regioisomeric and Exclusively Selective Hg(II) Sensor Molecules Composed of a Naphthalimide Fluorophore and an O- Phenylenediamine Derived Triamide Receptor. Chemical Communications 2006, 109-111.

(183) Guo, X.; Qian, X.; Jia, L. A Highly Selective and Sensitive Fluorescent Chemosensor for Hg2+ in Neutral Buffer Aqueous Solution. Journal of the American Chemical Society 2004, 126, 2272-2273.

(184) Tang, B.; Cui, L. J.; Xu, K. H.; Tong, L. L.; Yang, G. W.; An, L. G. A Sensitive and Selective Near-Infrared Fluorescent Probe for Mercuric Ions and Its Biological Imaging Applications. ChemBioChem 2008, 9, 1159-1164.

(185) Ou, S.; Lin, Z.; Duan, C.; Zhang, H.; Bai, Z. A Sugar-Quinoline Fluorescent Chemosensor for Selective Detection of Hg2+ Ion in Natural Water. Chemical Communications 2006, 4392-4394.

(186) Yuan, M.; Li, Y.; Li, J.; Li, C.; Liu, X.; Lv, J.; Xu, J.; Liu, H.; Wang, S.; Zhu, D. A Colorimetric and Fluorometric Dual-Modal Assay for Mercury Ion by a Molecule. Organic Letters 2007, 9, 2313-2316.

(187) Li, Q.; Peng, M.; Li, H.; Zhong, C.; Zhang, L.; Cheng, X.; Peng, X.; Wang, Q.; Qin, J.; Li, Z. A New “Turn-On” Naphthalenedimide-Based Chemosensor for Mercury Ions with High Selectivity: Successful Utilization of the Mechanism of Twisted Intramolecular Charge Transfer, near-Ir Fluorescence, and Cell Images. Organic Letters 2012, 14, 2094-2097.

(188) Yoon, S.; Albers, A. E.; Wong, A. P.; Chang, C. J. Screening Mercury Levels in Fish with a Selective Fluorescent Chemosensor. Journal of the American Chemical Society 2005, 127, 16030-16031.

(189) Nolan, E. M.; Lippard, S. J. Turn-On and Ratiometric Mercury Sensing in Water with a Red-Emitting Probe. Journal of the American Chemical Society 2007, 129, 5910-5918.

197

(190) Nolan, E. M.; Lippard, S. J. Ms4, a Seminaphthofluorescein-Based Chemosensor for the Ratiometric Detection of Hg(II). Journal of Materials Chemistry 2005, 15, 2778-2783.

(191) Nolan, E. M.; Racine, M. E.; Lippard, S. J. Selective Hg(II) Detection in Aqueous Solution with Thiol Derivatized Fluoresceins. Inorganic Chemistry 2006, 45, 2742- 2749.

(192) Nolan, E. M.; Lippard, S. J. A “Turn-On” Fluorescent Sensor for the Selective Detection of Mercuric Ion in Aqueous Media. Journal of the American Chemical Society 2003, 125, 14270-14271.

(193) Yan, F.; Cao, D.; Yang, N.; Yu, Q.; Wang, M.; Chen, L. A Selective Turn-On Fluorescent Chemosensor Based on Rhodamine for Hg2+ and Its Application in Live Cell Imaging. Sensors and Actuators B: Chemical 2012, 162, 313-320.

(194) Gao, B.; Gong, W.-T.; Zhang, Q.-L.; Ye, J.-W.; Ning, G.-L. A Selective “Turn-On” Fluorescent Sensor for Hg2+ Based on “Reactive” 7-Hydroxycoumarin Compound. Sensors and Actuators B: Chemical 2012, 162, 391-395.

(195) Suresh, M.; Mishra, S.; Mishra, S. K.; Suresh, E.; Mandal, A. K.; Shrivastav, A.; Das, A. Resonance Energy Transfer Approach and a New Ratiometric Probe for Hg2+ in Aqueous Media and Living Organism. Organic Letters 2009, 11, 2740- 2743.

(196) Lee, Y. H.; Lee, M. H.; Zhang, J. F.; Kim, J. S. Pyrene Excimer-Based Calix[4]Arene Fret Chemosensor for Mercury(II). The Journal of Organic Chemistry 2010, 75, 7159-7165.

(197) Huang, W.; Song, C.; He, C.; Lv, G.; Hu, X.; Zhu, X.; Duan, C. Recognition Preference of Rhodamine-Thiospirolactams for Mercury(II) in Aqueous Solution. Inorganic Chemistry 2009, 48, 5061-5072.

(198) Wu, D.; Huang, W.; Duan, C.; Lin, Z.; Meng, Q. Highly Sensitive Fluorescent Probe for Selective Detection of Hg2+ in Dmf Aqueous Media. Inorganic Chemistry 2007, 46, 1538-1540.

(199) Kim, H. N.; Nam, S.-W.; Swamy, K. M. K.; Jin, Y.; Chen, X.; Kim, Y.; Kim, S.-J.; Park, S.; Yoon, J. Rhodamine Hydrazone Derivatives as Hg2+ Selective Fluorescent and Colorimetric Chemosensors and Their Applications to Bioimaging and Microfluidic System. Analyst 2011, 136, 1339-1343.

(200) Kim, S. K.; Swamy, K. M. K.; Chung, S.-Y.; Kim, H. N.; Kim, M. J.; Jeong, Y.; Yoon, J. New Fluorescent and Colorimetric Chemosensors Based on the

198

Rhodamine and Boronic Acid Groups for the Detection of Hg2+. Tetrahedron Letters 2010, 51, 3286-3289.

(201) Kim, H.; Lee, S.; Lee, J.; Tae, J. Rhodamine Triazole-Based Fluorescent Probe for the Detection of Pt2+. Organic Letters 2010, 12, 5342-5345.

(202) Callan, J. F.; de Silva, A. P.; Magri, D. C. Luminescent Sensors and Switches in the Early 21st Century. Tetrahedron 2005, 61, 8551-8588.

(203) Yekta, A.; Duhamel, J.; Winnik, M. A. Dipole-Dipole Electronic Energy Transfer. Fluorescence Decay Functions for Arbitrary Distributions of Donors and Acceptors: Systems with Planar Geometry. Chemical Physics Letters 1995, 235, 119-125.

(204) Steinberg, I. Z. Long-Range Nonradiative Transfer of Electronic Excitation Energy in Proteins and Polypeptides. Annual Review of Biochemistry 1971, 40, 83-114.

(205) Stryer, L. Fluorescence Energy Transfer as a Spectroscopic Ruler. Annual Review of Biochemistry 1978, 47, 819-846.

(206) Han, Z.-X.; Zhang, X.-B.; Li, Z.; Gong, Y.-J.; Wu, X.-Y.; Jin, Z.; He, C.-M.; Jian, L.- X.; Zhang, J.; Shen, G.-L.; Yu, R.-Q. Efficient Fluorescence Resonance Energy Transfer-Based Ratiometric Fluorescent Cellular Imaging Probe for Zn2+ Using a Rhodamine Spirolactam as a Trigger. Analytical Chemistry 2010, 82, 3108-3113.

(207) Beija, M.; Afonso, C. A. M.; Martinho, J. M. G. Synthesis and Applications of Rhodamine Derivatives as Fluorescent Probes. Chemical Society Reviews 2009, 38, 2410-2433.

(208) Valeur, B.; Leray, I. Design Principles of Fluorescent Molecular Sensors for Cation Recognition. Coordination Chemistry Reviews 2000, 205, 3-40.

(209) Komatsu, K.; Urano, Y.; Kojima, H.; Nagano, T. Development of an Iminocoumarin-Based Zinc Sensor Suitable for Ratiometric Fluorescence Imaging of Neuronal Zinc. Journal of the American Chemical Society 2007, 129, 13447- 13454.

(210) Grynkiewicz, G.; Poenie, M.; Tsien, R. Y. A New Generation of Ca2+ Indicators with Greatly Improved Fluorescence Properties. Journal of Biological Chemistry 1985, 260, 3440-3450.

(211) Tsien, R. Y. Fluorescence Measurement and Photochemical Manipulation of Cytosolic Free Calcium. Trends in Neurosciences 1988, 11, 419-424.

(212) Nolan, E. M.; Lippard, S. J. Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry. Accounts of Chemical Research 2008, 42, 193-203. 199

(213) El Majzoub, A.; Cadiou, C.; D champs-Olivier, I.; Tinant, B.; Chuburu, F. o. Cyclam-Methylbenzimidazole: A Selective Off-on Fluorescent Sensor for Zinc. Inorganic Chemistry 2011, 50, 4029-4038.

(214) Gee, K. R.; Zhou, Z.-L.; Qian, W.-J.; Kennedy, R. Detection and Imaging of Zinc Secretion from Pancreatic Β-Cells Using a New Fluorescent Zinc Indicator. Journal of the American Chemical Society 2002, 124, 776-778.

(215) Zhao, J.; Bertoglio, B. A.; Gee, K. R.; Kay, A. R. The Zinc Indicator Fluozin-3 Is Not Perturbed Significantly by Physiological Levels of Calcium or Magnesium. Cell Calcium 2008, 44, 422-426.

(216) Schmidtchen, F. P.; Berger, M. Artificial Organic Host Molecules for Anions. Chemical Reviews 1997, 97, 1609-1646.

(217) Lankshear, M. D.; Beer, P. D. Strategic Anion Templation. Coordination Chemistry Reviews 2006, 250, 3142-3160.

(218) Moragues, M. E.; Martinez-Manez, R.; Sancenon, F. Chromogenic and Fluorogenic Chemosensors and Reagents for Anions. A Comprehensive Review of the Year 2009. Chemical Society Reviews 2011, 40, 2593-2643.

(219) Martínez-Máñez, R.; Sancenón, F. Fluorogenic and Chromogenic Chemosensors and Reagents for Anions. Chemical Reviews 2003, 103, 4419-4476.

(220) Kubik, S. Amino Acid Containing Anion Receptors. Chemical Society Reviews 2009, 38, 585-605.

(221) Katayev, E. A.; Ustynyuk, Y. A.; Sessler, J. L. Receptors for Tetrahedral Oxyanions. Coordination Chemistry Reviews 2006, 250, 3004-3037.

(222) Kang, S. O.; Begum, R. A.; Bowman-James, K. Amide-Based Ligands for Anion Coordination. Angewandte Chemie International Edition 2006, 45, 7882-7894.

(223) Gunnlaugsson, T.; Glynn, M.; Tocci, G. M.; Kruger, P. E.; Pfeffer, F. M. Anion Recognition and Sensing in Organic and Aqueous Media Using Luminescent and Colorimetric Sensors. Coordination Chemistry Reviews 2006, 250, 3094-3117.

(224) Gale, P. A.; Garcia-Garrido, S. E.; Garric, J. Anion Receptors Based on Organic Frameworks: Highlights from 2005 and 2006. Chemical Society Reviews 2008, 37, 151-190.

(225) Gale, P. A. Anion Receptor Chemistry: Highlights from 2008 and 2009. Chemical Society Reviews 2010, 39, 3746-3771.

200

(226) Shannon, R. D. Revised Effective Ionic Radii and Systematic Studies of Interatomic Distances in Halides and Chalcogenides. Acta Crystallographica Section A 1976, 32, 751-767.

(227) Beer, P. D.; Gale, P. A. Anion Recognition and Sensing: The State of the Art and Future Perspectives. Angewandte Chemie International Edition 2001, 40, 486-516.

(228) Schmidtchen, F. P. Inclusion of Anions in Macrotricyclic Quaternary Ammonium Salts. Angewandte Chemie International Edition 1977, 16, 720-721.

(229) Schmidtchen, F. P. Synthese Makrotricyclischer Amine. Chemische Berichte 1980, 113, 864-874.

(230) Müller-Dethlefs, K.; Hobza, P. Noncovalent Interactions: A Challenge for Experiment and Theory. Chemical Reviews 1999, 100, 143-168.

(231) Beauchamp, A. L.; Olivier, M. J.; Wuest, J. D.; Zacharie, B. Multidentate Lewis Acids. Crystal Structure of the 2:1 Adduct of 1,2-Phenylenedimercury Dichloride with Tetraphenylphosphonium Chloride. Journal of the American Chemical Society 1986, 108, 73-77.

(232) Shur, V. B.; Tikhonova, I. A.; Dolgushin, F. M.; Yanovsky, A. I.; Struchkov, Y. T.; Volkonsky, A. Y.; Solodova, E. V.; Panov, S. Y.; Petrovskii, P. V.; Vol'pin, M. E. Crown Compounds for Anions. A Spinning Top-Shaped Complex of Cyclic Pentameric Perfluoroisopropylidenemercury with Two Chloride Anions. Journal of Organometallic Chemistry 1993, 443, C19-C21.

(233) Shur, V. B.; Tikhonova, I. A.; Yanovsky, A. I.; Struchkov, Y. T.; Petrovskii, P. V.; Panov, S. Y.; Furin, G. G.; Vol'pin, M. E. Crown Compounds for Anions. Unusual Complex of Trimetric Perfluoro-O-Phenylenemercury with the Bromide Anion Having a Polydecker Sandwich Structure. Journal of Organometallic Chemistry 1991, 418, C29-C32.

(234) Tikhonova, I. A.; Dolgushin, F. M.; Yanovsky, A. I.; Struchkov, Y. T.; Gavrilova, A. N.; Saitkulova, L. N.; Shubina, E. S.; Epstein, L. M.; Furin, G. G.; Shur, V. B. Crown Compounds for Anions. A Polymeric Complex of Cyclic Trimeric Perfluoro- O-Phenylenemercury with Thiocyanate Anion Containing an Infinite Helical Chain of Alternating Molecules of Mercury-Containing Macrocycle and SCN− Ions. Journal of Organometallic Chemistry 1996, 508, 271-273.

(235) Wuest, J. D.; Zacharie, B. Multidentate Lewis Acids. Halide Complexes of 1,2- Phenylenedimercury Dihalides. Organometallics 1985, 4, 410-411.

201

(236) Aoyagi, S.; Tanaka, K.; Zicmane, I.; Takeuchi, Y. Nuclear Magnetic Resonance Spectra of Organogermanium Compounds. Part 11. Synthesis and Nuclear Magnetic Resonance Spectra of Tetramethyldigerma- and Octamethyltetragerma- Cycloalkanes. Journal of the Chemical Society, Perkin Transactions 2 1992, 2217- 2220.

(237) Ogawa, K.; Aoyagi, S.; Takeuchi, Y. Molecular Structure of 1,1,8,8-Tetramethyl- 1,8-Digermacyclotetradecane: The First 14-Membered Germacycles. Journal of the Chemical Society, Perkin Transactions 2 1993, 2389-2392.

(238) Azuma, Y.; Newcomb, M. Macrocycles Containing Tin. Syntheses of Symmetrical Macrocycles Containing Two or Four Diphenylstanna Units. Organometallics 1984, 3, 9-14.

(239) Newcomb, M.; Blanda, M. T.; Azuma, Y.; Delord, T. J. Macrocycles Containing Tin. Synthesis and Structure of 1,10-Diphenyl-1,10-Distannabicyclo[8.8.8]Hexacosane. Journal of the Chemical Society, Chemical Communications 1984, 1159-1160.

(240) Newcomb, M.; Horner, J. H.; Blanda, M. T. Macrocycles Containing Tin. Through Space Cooperative Binding and High Size Selectivity in the Complexation of Chloride Ion by Lewis Acidic Macrobicyclic Hosts. Journal of the American Chemical Society 1987, 109, 7878-7879.

(241) Newcomb, M.; Madonik, A. M.; Blanda, M. T.; Judice, J. K. Macrocycles Containing Tin. Tin-119 NMR Studies of Chloride Binding by Lewis Acidic Tin Compounds. Organometallics 1987, 6, 145-150.

(242) Pascal Jr, R. A.; Spergel, J.; Van Engen, D. Synthesis and X-Ray Crystallographic Characterization of a (1,3,5)Cyclophane with Three Amide N-H Groups Surrounding a Central Cavity. A Neutral Host for Anion Complexation. Tetrahedron Letters 1986, 27, 4099-4102.

(243) Amendola, V.; Bonizzoni, M.; Esteban-Gómez, D.; Fabbrizzi, L.; Licchelli, M.; Sancenón, F.; Taglietti, A. Some Guidelines for the Design of Anion Receptors. Coordination Chemistry Reviews 2006, 250, 1451-1470.

(244) Gale, P. A. Structural and Molecular Recognition Studies with Acyclic Anion Receptors†. Accounts of Chemical Research 2006, 39, 465-475.

(245) Gale, P. A.; Quesada, R. Anion Coordination and Anion-Templated Assembly: Highlights from 2002 to 2004. Coordination Chemistry Reviews 2006, 250, 3219- 3244.

202

(246) Caltagirone, C.; Gale, P. A. Anion Receptor Chemistry: Highlights from 2007. Chemical Society Reviews 2009, 38, 520-563.

(247) Li, A.-F.; Wang, J.-H.; Wang, F.; Jiang, Y.-B. Anion Complexation and Sensing Using Modified Urea and Thiourea-Based Receptors. Chemical Society Reviews 2010, 39, 3729-3745.

(248) Gale, P. A.; Sessler, J. L.; Král, V.; Lynch, V. Calix[4]Pyrroles: Old yet New Anion- Binding Agents. Journal of the American Chemical Society 1996, 118, 5140-5141.

(249) Bühlmann, P.; Nishizawa, S.; Xiao, K. P.; Umezawa, Y. Strong Hydrogen Bond- Mediated Complexation of H2PO4− by Neutral Bis-Thiourea Hosts. Tetrahedron 1997, 53, 1647-1654.

(250) Beer, P. D. Anion Selective Recognition and Optical/Electrochemical Sensing by Novel Transition-Metal Receptor Systems. Chemical Communications 1996, 689- 696.

(251) Beer, P. D. Transition-Metal Receptor Systems for the Selective Recognition and Sensing of Anionic Guest Species. Accounts of Chemical Research 1998, 31, 71- 80.

(252) M. G. Antonisse, M.; N. Reinhoudt, D. Neutral Anion Receptors: Design and Application. Chemical Communications 1998, 443-448.

(253) Beer, P. D.; Drew, M. G. B.; Hesek, D.; Shade, M.; Szemes, F. Anion Recognition Properties of New-Rim Bis[Rhenium(I) Bipyridyl, Ruthenium(II) Bis(Bipyridyl), Cobaltocenium]Calix[4]Arene Receptors Dictated by Lower-Rim Substituents. Chemical Communications 1996, 2161-2162.

(254) Beer, P. D.; Hesek, D.; Nam, K. C.; Drew, M. G. B. Anion Recognition Properties of New Upper-Rim Cobaltocenium Calix[4]Arene Receptors. Organometallics 1999, 18, 3933-3943.

(255) D. Beer, P.; G. B. Drew, M.; Hesek, D.; Chun Nam, K. A New Carboxylate Anion Selective Cobaltocenium Calix[4]Arene Receptor. Chemical Communications 1997, 107-108.

(256) Black, C. B.; Andrioletti, B.; Try, A. C.; Ruiperez, C.; Sessler, J. L. Dipyrrolylquinoxalines: Efficient Sensors for Fluoride Anion in Organic Solution. Journal of the American Chemical Society 1999, 121, 10438-10439.

(257) Liao, J.-H.; Chen, C.-T.; Fang, J.-M. A Novel Phosphate Chemosensor Utilizing Anion-Induced Fluorescence Change. Organic Letters 2002, 4, 561-564.

203

(258) Kolb, H. C.; Finn, M. G.; Sharpless, K. B. Click Chemistry: Diverse Chemical Function from a Few Good Reactions. Angewandte Chemie International Edition 2001, 40, 2004-2021.

(259) Kolb, H. C.; Sharpless, K. B. The Growing Impact of Click Chemistry on Drug Discovery. Drug Discovery Today 2003, 8, 1128-1137.

(260) Tornøe, C. W.; Christensen, C.; Meldal, M. Peptidotriazoles on Solid Phase: [1,2,3]-Triazoles by Regiospecific Copper(I)-Catalyzed 1,3-Dipolar Cycloadditions of Terminal Alkynes to Azides. The Journal of Organic Chemistry 2002, 67, 3057- 3064.

(261) Rostovtsev, V. V.; Green, L. G.; Fokin, V. V.; Sharpless, K. B. A Stepwise Huisgen Cycloaddition Process: Copper(I)-Catalyzed Regioselective “Ligation” of Azides and Terminal Alkynes. Angewandte Chemie International Edition 2002, 41, 2596-2599.

(262) Himo, F.; Lovell, T.; Hilgraf, R.; Rostovtsev, V. V.; Noodleman, L.; Sharpless, K. B.; Fokin, V. V. Copper(I)-Catalyzed Synthesis of Azoles. Dft Study Predicts Unprecedented Reactivity and Intermediates. Journal of the American Chemical Society 2004, 127, 210-216.

(263) Bodine, K. D.; Gin, D. Y.; Gin, M. S. Synthesis of Readily Modifiable Cyclodextrin Analogues Via Cyclodimerization of an Alkynyl−Azido Trisaccharide. Journal of the American Chemical Society 2004, 126, 1638-1639.

(264) Ladmiral, V.; Mantovani, G.; Clarkson, G. J.; Cauet, S.; Irwin, J. L.; Haddleton, D. M. Synthesis of Neoglycopolymers by a Combination of “Click Chemistry” and Living Radical Polymerization. Journal of the American Chemical Society 2006, 128, 4823-4830.

(265) Link, A. J.; Tirrell, D. A. Cell Surface Labeling of Escherichia Coli Via Copper(I)- Catalyzed [3+2] Cycloaddition. Journal of the American Chemical Society 2003, 125, 11164-11165.

(266) Lutz, J.-F. 1,3-Dipolar Cycloadditions of Azides and Alkynes: A Universal Ligation Tool in and Materials Science. Angewandte Chemie International Edition 2007, 46, 1018-1025.

(267) Punna, S.; Kuzelka, J.; Wang, Q.; Finn, M. G. Head-to-Tail Peptide Cyclodimerization by Copper-Catalyzed Azide–Alkyne Cycloaddition. Angewandte Chemie International Edition 2005, 44, 2215-2220.

204

(268) Rodionov, V. O.; Fokin, V. V.; Finn, M. G. Mechanism of the Ligand-Free CuI- Catalyzed Azide–Alkyne Cycloaddition Reaction. Angewandte Chemie International Edition 2005, 44, 2210-2215.

(269) Wang, Q.; Chan, T. R.; Hilgraf, R.; Fokin, V. V.; Sharpless, K. B.; Finn, M. G. Bioconjugation by Copper(I)-Catalyzed Azide-Alkyne [3 + 2] Cycloaddition. Journal of the American Chemical Society 2003, 125, 3192-3193.

(270) Wu, P.; Feldman, A. K.; Nugent, A. K.; Hawker, C. J.; Scheel, A.; Voit, B.; Pyun, J.; Fréchet, J. M. J.; Sharpless, K. B.; Fokin, V. V. Efficiency and Fidelity in a Click- Chemistry Route to Triazole Dendrimers by the Copper(I)-Catalyzed Ligation of Azides and Alkynes. Angewandte Chemie International Edition 2004, 43, 3928- 3932.

(271) Kumar, A.; Pandey, P. S. Anion Recognition by 1,2,3-Triazolium Receptors: Application of Click Chemistry in Anion Recognition. Organic Letters 2007, 10, 165-168.

(272) Farley; Wergedal, J.; Baylink, D. Fluoride Directly Stimulates Proliferation and Alkaline Phosphatase Activity of Bone-Forming Cells. Science 1983, 222, 330-332.

(273) Griffin, S. O.; Regnier, E.; Griffin, P. M.; Huntley, V. Effectiveness of Fluoride in Preventing Caries in Adults. Journal of Dental Research 2007, 86, 410-415.

(274) Horowitz, H. S. The 2001 Cdc Recommendations for Using Fluoride to Prevent and Control Dental Caries in the United States. Journal of Public Health Dentistry 2003, 63, 3-8.

(275) McDonagh, M. S.; Whiting, P. F.; Wilson, P. M.; Sutton, A. J.; Chestnutt, I.; Cooper, J.; Misso, K.; Bradley, M.; Treasure, E.; Kleijnen, J. Systematic Review of Water Fluoridation. BMJ 2000, 321, 855-859.

(276) Winston, A. E.; Bhaskar, S. N. Caries Prevention in the 21st Century. The Journal of the American Dental Association 1998, 129, 1579-1587.

(277) Kleerekoper, M. The Role of Fluoride in the Prevention of Osteoporosis. Endocrinology and Metabolism Clinics of North America 1998, 27, 441-452.

(278) Arhima, M. H.; Gulati, O. P.; Sharma, S. C. The Effect of Pycnogenol on Fluoride Induced Rat Kidney Lysosomal Damage in Vitro. Phytotherapy Research 2004, 18, 244-246.

(279) Matsui, H.; Morimoto, M.; Horimoto, K.; Nishimura, Y. Some Characteristics of Fluoride-Induced Cell Death in Rat Thymocytes: Cytotoxicity of Sodium Fluoride. Toxicology in Vitro 2007, 21, 1113-1120. 205

(280) Hirano, S.; Ando, M. Apoptotic Cell Death Following Exposure to Fluoride in Rat Alveolar Macrophages. Arch Toxicol 1996, 70, 249-251.

(281) Bao, Y.; Liu, B.; Wang, H.; Tian, J.; Bai, R. A "Naked Eye" and Ratiometric Fluorescent Chemosensor for Rapid Detection of F- Based on Combination of Desilylation Reaction and Excited-State Proton Transfer. Chemical Communications 2011, 47, 3957-3959.

(282) Cao, X.; Lin, W.; Yu, Q.; Wang, J. Ratiometric Sensing of Fluoride Anions Based on a Bodipy-Coumarin Platform. Organic Letters 2011, 13, 6098-6101.

(283) Cho, E. J.; Ryu, B. J.; Lee, Y. J.; Nam, K. C. Visible Colorimetric Fluoride Ion Sensors. Organic Letters 2005, 7, 2607-2609.

(284) Kim, S. Y.; Park, J.; Koh, M.; Park, S. B.; Hong, J.-I. Fluorescent Probe for Detection of Fluoride in Water and Bioimaging in A549 Human Lung Carcinoma Cells. Chemical Communications 2009, 4735-4737.

(285) Lee, M. H.; Agou, T.; Kobayashi, J.; Kawashima, T.; Gabbai, F. P. Fluoride Ion Complexation by a Cationic Borane in Aqueous Solution. Chemical Communications 2007, 1133-1135.

(286) Lin, Z.-h.; Ou, S.-j.; Duan, C.-y.; Zhang, B.-g.; Bai, Z.-p. Naked-Eye Detection of Fluoride Ion in Water: A Remarkably Selective Easy-to-Prepare Test Paper. Chemical Communications 2006, 624-626.

(287) Zhang, J. F.; Lim, C. S.; Bhuniya, S.; Cho, B. R.; Kim, J. S. A Highly Selective Colorimetric and Ratiometric Two-Photon Fluorescent Probe for Fluoride Ion Detection. Organic Letters 2011, 13, 1190-1193.

(288) Zhu, B.; Yuan, F.; Li, R.; Li, Y.; Wei, Q.; Ma, Z.; Du, B.; Zhang, X. A Highly Selective Colorimetric and Ratiometric Fluorescent Chemodosimeter for Imaging Fluoride Ions in Living Cells. Chemical Communications 2011, 47, 7098-7100.

(289) Kim, S. K.; Yoon, J. A New Fluorescent Pet Chemosensor for Fluoride Ions. Chemical Communications 2002, 770-771.

(290) Cho, E. J.; Moon, J. W.; Ko, S. W.; Lee, J. Y.; Kim, S. K.; Yoon, J.; Nam, K. C. A New Fluoride Selective Fluorescent as Well as Chromogenic Chemosensor Containing a Naphthalene Urea Derivative. Journal of the American Chemical Society 2003, 125, 12376-12377.

(291) Chen, Q.-Y.; Chen, C.-F. A New Fluorescent as Well as Chromogenic Chemosensor for Anions Based on an Anthracene Carbamate Derivative. Tetrahedron Letters 2004, 45, 6493-6496. 206

(292) Jun, E. J.; Swamy, K. M. K.; Bang, H.; Kim, S.-J.; Yoon, J. Anthracene Derivatives Bearing Thiourea Group as Fluoride Selective Fluorescent and Colorimetric Chemosensors. Tetrahedron Letters 2006, 47, 3103-3106.

(293) Hu, R.; Feng, J.; Hu, D.; Wang, S.; Li, S.; Li, Y.; Yang, G. A Rapid Aqueous Fluoride Ion Sensor with Dual Output Modes. Angewandte Chemie International Edition 2010, 49, 4915-4918.

(294) Kim, S. Y.; Hong, J.-I. Chromogenic and Fluorescent Chemodosimeter for Detection of Fluoride in Aqueous Solution. Organic Letters 2007, 9, 3109-3112.

(295) Bozdemir, O. A.; Sozmen, F.; Buyukcakir, O.; Guliyev, R.; Cakmak, Y.; Akkaya, E. U. Reaction-Based Sensing of Fluoride Ions Using Built-in Triggers for Intramolecular Charge Transfer and Photoinduced Electron Transfer. Organic Letters 2010, 12, 1400-1403.

(296) Sokkalingam, P.; Lee, C.-H. Highly Sensitive Fluorescence “Turn-On” Indicator for Fluoride Anion with Remarkable Selectivity in Organic and Aqueous Media. The Journal of Organic Chemistry 2011, 76, 3820-3828.

(297) R. Cooper, C.; Spencer, N.; D. James, T. Selective Fluorescence Detection of Fluoride Using Boronic Acids. Chemical Communications 1998, 1365-1366.

(298) Wade, C. R.; Broomsgrove, A. E. J.; Aldridge, S.; Gabbaï, F. P. Fluoride Ion Complexation and Sensing Using Organoboron Compounds. Chemical Reviews 2010, 110, 3958-3984.

(299) Arimori, S.; Davidson, M. G.; Fyles, T. M.; Hibbert, T. G.; James, T. D.; Kociok- Kohn, G. I. Synthesis and Structural Characterisation of the First Bis(Bora)Calixarene: A Selective, Bidentate, Fluorescent Fluoride Sensor. Chemical Communications 2004, 1640-1641.

(300) Xu, Z.; Kim, S. K.; Han, S. J.; Lee, C.; Kociok-Kohn, G.; James, T. D.; Yoon, J. Ratiometric Fluorescence Sensing of Fluoride Ions by an Asymmetric Bidentate Receptor Containing a Boronic Acid and Imidazolium Group. European Journal of Organic Chemistry 2009, 2009, 3058-3065.

(301) Melaïmi, M.; Solé, S.; Chiu, C.-W.; Wang, H.; Gabbaï, F. P. Structural and Electrochemical Investigations of the High Fluoride Affinity of Sterically Hindered 1,8-Bis(Boryl)Naphthalenes. Inorganic Chemistry 2006, 45, 8136-8143.

(302) Katz, H. E. Hydride Sponge: Complexation of 1,8- Naphthalenediylbis(Dimethylborane) with Hydride, Fluoride, and Hydroxide. The Journal of Organic Chemistry 1985, 50, 5027-5032.

207

(303) Kubo, Y.; Kobayashi, A.; Ishida, T.; Misawa, Y.; James, T. D. Detection of Anions Using a Fluorescent Alizarin-Phenylboronic Acid Ensemble. Chemical Communications 2005, 2846-2848.

(304) Swamy, K. M. K.; Lee, Y. J.; Lee, H. N.; Chun, J.; Kim, Y.; Kim, S.-J.; Yoon, J. A New Fluorescein Derivative Bearing a Boronic Acid Group as a Fluorescent Chemosensor for Fluoride Ion. The Journal of Organic Chemistry 2006, 71, 8626- 8628.

(305) Melaimi, M.; Gabbaï, F. P. A Heteronuclear Bidentate Lewis Acid as a Phosphorescent Fluoride Sensor. Journal of the American Chemical Society 2005, 127, 9680-9681.

(306) Liu, Z.-Q.; Shi, M.; Li, F.-Y.; Fang, Q.; Chen, Z.-H.; Yi, T.; Huang, C.-H. Highly Selective Two-Photon Chemosensors for Fluoride Derived from Organic Boranes. Organic Letters 2005, 7, 5481-5484.

(307) Liu, X. Y.; Bai, D. R.; Wang, S. Charge-Transfer Emission in Nonplanar Three- Coordinate Organoboron Compounds for Fluorescent Sensing of Fluoride. Angewandte Chemie International Edition 2006, 45, 5475-5478.

(308) Sundararaman, A.; Venkatasubbaiah, K.; Victor, M.; Zakharov, L. N.; Rheingold, A. L.; Jäkle, F. Electronic Communication and Negative Binding Cooperativity in Diborylated Bithiophenes. Journal of the American Chemical Society 2006, 128, 16554-16565.

(309) Yamaguchi, S.; Akiyama, S.; Tamao, K. Colorimetric Fluoride Ion Sensing by Boron-Containing π-Electron Systems. Journal of the American Chemical Society 2001, 123, 11372-11375.

(310) Yamaguchi, S.; Shirasaka, T.; Akiyama, S.; Tamao, K. Dibenzoborole-Containing π-Electron Systems: Remarkable Fluorescence Change Based on the “On/Off” Control of the Pπ−π* Conjugation. Journal of the American Chemical Society 2002, 124, 8816-8817.

(311) Ke, I.-S.; Myahkostupov, M.; Castellano, F. N.; Gabbaï, F. P. Stibonium Ions for the Fluorescence Turn-On Sensing of F– in Drinking Water at Parts Per Million Concentrations. Journal of the American Chemical Society 2012, 134, 15309- 15311.

(312) Amendola, V.; Esteban-Gómez, D.; Fabbrizzi, L.; Licchelli, M. What Anions Do to N−H-Containing Receptors. Accounts of Chemical Research 2006, 39, 343-353.

208

(313) Bhosale, S. V.; Bhosale, S. V.; Kalyankar, M. B.; Langford, S. J. A Core- Substituted Naphthalene Diimide Fluoride Sensor. Org Lett 2009, 11, 5418-5421.

(314) Esteban-Gómez, D.; Fabbrizzi, L.; Licchelli, M. Why, on Interaction of Urea-Based Receptors with Fluoride, Beautiful Colors Develop. J. Org. Chem. 2005, 70, 5717- 5720.

(315) Peng, X.; Wu, Y.; Fan, J.; Tian, M.; Han, K. Colorimetric and Ratiometric Fluorescence Sensing of Fluoride: Tuning Selectivity in Proton Transfer. J. Org. Chem. 2005, 70, 10524-10531.

(316) Wang, Q.; Xie, Y.; Ding, Y.; Li, X.; Zhu, W. Colorimetric Fluoride Sensors Based on Deprotonation of Pyrrole-Hemiquinone Compounds. Chem Commun 2010, 46, 3669-3671.

(317) Qu, Y.; Hua, J.; Tian, H. Colorimetric and Ratiometric Red Fluorescent Chemosensor for Fluoride Ion Based on Diketopyrrolopyrrole. Organic Letters 2010, 12, 3320-3323.

(318) Cao, Q.-Y.; Pradhan, T.; Lee, M. H.; No, K.; Kim, J. S. Ferrocene-Based Anion Receptor Bearing Amide and Triazolium Donor Groups. Analyst 2012, 137, 4454- 4457.

(319) Grisorio, R.; Allegretta, G.; Mastrorilli, P.; Suranna, G. P. On the Degradation Process Involving Polyfluorenes and the Factors Governing Their Spectral Stability. Macromolecules 2011, 44, 7977-7986.

(320) Chen, C.-H.; Hsu, Y.-C.; Chou, H.-H.; Thomas, K. R. J.; Lin, J. T.; Hsu, C.-P. Dipolar Compounds Containing Fluorene and a Heteroaromatic Ring as the Conjugating Bridge for High-Performance Dye-Sensitized Solar Cells. Chemistry – A European Journal 2010, 16, 3184-3193.

(321) Lee, K. H.; Kwon, Y. S.; Kang, L. K.; Kim, G. Y.; Seo, J. H.; Kim, Y. K.; Yoon, S. S. Blue Organic Light-Emitting Materials Based on Diphenylaminofluorene and N- Phenylcarbazole Derivatives. Synthetic Met 2009, 159, 2603-2608.

(322) Descalzo, A. B.; Rurack, K.; Weisshoff, H.; Martínez-Máñez, R.; Marcos, M. D.; Amorós, P.; Hoffmann, K.; Soto, J. Rational Design of a Chromo- and Fluorogenic Hybrid Chemosensor Material for the Detection of Long-Chain Carboxylates. J Am Chem Soc 2004, 127, 184-200.

(323) Shenderovich, I. G.; Limbach, H.-H.; Smirnov, S. N.; Tolstoy, P. M.; Denisov, G. S.; Golubev, N. S. H/D Isotope Effects on the Low-Temperature NMR Parameters

209

and Hydrogen Bond Geometries of (Fh)2f- and (Fh)3f- Dissolved in Cdf3/Cdf2cl. Phys Chem Chem Phys 2002, 4, 5488-5497.

(324) Burnell, J. M.; Villamil, M. F.; Uyeno, B. T.; Scribner, B. H. The Effect in Humans of Extracellular Ph Change on the Relationship between Serum Potassium Concentration and Intracellular Potassium. The Journal of Clinical Investigation 1956, 35, 935-939.

(325) Elkinton, J. R.; Winkler, A. W. Transfers of Imtracellular Potassium in Experimental Dehydration. The Journal of Clinical Investigation 1944, 23, 93-101.

(326) Teresa, M.; Gomes, S. R.; Tavares, K. S.; Oliveira, J. A. B. P. The Quantification of Potassium Using a Quartz Crystal Microbalance. Analyst 2000, 125, 1983-1986.

(327) Ueyama, H.; Takagi, M.; Takenaka, S. A Novel Potassium Sensing in Aqueous Media with a Synthetic Oligonucleotide Derivative. Fluorescence Resonance Energy Transfer Associated with Guanine Quartet−Potassium Ion Complex Formation. Journal of the American Chemical Society 2002, 124, 14286-14287.

(328) He, F.; Tang, Y.; Wang, S.; Li, Y.; Zhu, D. Fluorescent Amplifying Recognition for DNA G-Quadruplex Folding with a Cationic Conjugated Polymer: A Platform for Homogeneous Potassium Detection. Journal of the American Chemical Society 2005, 127, 12343-12346.

(329) Kuo, H.-C.; Cheng, C.-F.; Clark, R. B.; Lin, J. J. C.; Lin, J. L. C.; Hoshijima, M.; Nguyêñ-Trân, V. T. B.; Gu, Y.; Ikeda, Y.; Chu, P.-H.; Ross Jr, J.; Giles, W. R.; Chien, K. R. A Defect in the Kv Channel-Interacting Protein 2 (Kchip2) Gene Leads to a Complete Loss of Ito and Confers Susceptibility to Ventricular Tachycardia. Cell 2001, 107, 801-813.

(330) Bonnet, S.; Archer, S. L.; Allalunis-Turner, J.; Haromy, A.; Beaulieu, C.; Thompson, R.; Lee, C. T.; Lopaschuk, G. D.; Puttagunta, L.; Bonnet, S.; Harry, G.; Hashimoto, K.; Porter, C. J.; Andrade, M. A.; Thebaud, B.; Michelakis, E. D. A Mitochondria-K+ Channel Axis Is Suppressed in Cancer and Its Normalization Promotes Apoptosis and Inhibits Cancer Growth. Cancer Cell 2007, 11, 37-51.

(331) Hudgins, P. M.; Weiss, G. B. Differential Effects of Calcium Removal Upon Vascular Smooth Muscle Contraction Induced by Norepinephrine, Histamine and Potassium. Journal of Pharmacology and Experimental Therapeutics 1968, 159, 91-97.

(332) Kofuji, P.; Newman, E. A. Potassium Buffering in the Central Nervous System. Neuroscience 2004, 129, 1043-1054.

210

(333) Shieh, C.-C.; Coghlan, M.; Sullivan, J. P.; Gopalakrishnan, M. Potassium Channels: Molecular Defects, Diseases, and Therapeutic Opportunities. Pharmacological Reviews 2000, 52, 557-594.

(334) Wickenden, A. D. K+ Channels as Therapeutic Drug Targets. Pharmacology & Therapeutics 2002, 94, 157-182.

(335) Laurent, L. P. E.; Walther, W. W. The Influence of Large Doses of Potassium Chloride on Myasthenia Gravis. The Lancet 1935, 225, 1434-1435.

(336) Somjen, G. G.; Giacchino, J. L. Potassium and Calcium Concentrations in Interstitial Fluid of Hippocampal Formation During Paroxysmal Responses. Journal of Neurophysiology 1985, 53, 1098-1108.

(337) Grimm, R. H.; Neaton, J. D.; Elmer, P. J.; Svendsen, K. H.; Levin, J.; Segal, M.; Holland, L.; Witte, L. J.; Clearman, D. R.; Kofron, P.; LaBounty, R. K.; Crow, R.; Prineas, R. J. The Influence of Oral Potassium Chloride on Blood Pressure in Hypertensive Men on a Low-Sodium Diet. New England Journal of Medicine 1990, 322, 569-574.

(338) Kager, H.; Wadman, W. J.; Somjen, G. G. Simulated Seizures and Spreading Depression in a Neuron Model Incorporating Interstitial Space and Ion Concentrations. Journal of Neurophysiology 2000, 84, 495-512.

(339) Gonçalves, A. R.; Nahas, A. M. High Serum Potassium Levels after Using Losartan Can Reflect More Severe Renal Disease. Diabetologia 2011, 54, 2963- 2964.

(340) Brennan, C. H.; Lewis, A.; Littleton, J. M. Membrane Receptors, Involved in up- Regulation of Calcium Channels in Bovine Adrenal Chromaffin Cells, Chronically Exposed to Ethanol. Neuropharmacology 1989, 28, 1303-1307.

(341) Kunzelmann, K. Ion Channels and Cancer. J Membrane Biol 2005, 205, 159-173.

(342) MacGregor, L. C.; Matschinsky, F. M. Altered Retinal Metabolism in Diabetes. Ii. Measurement of Sodium-Potassium Atpase and Total Sodium and Potassium in Individual Retinal Layers. Journal of Biological Chemistry 1986, 261, 4052-4058.

(343) Mitchell, J. E.; Pyle, R. L.; Eckert, E. D.; Hatsukami, D.; Lentz, R. Electrolyte and Other Physiological Abnormalities in Patients with Bulimia. Psychological Medicine 1983, 13, 273-278.

(344) Frant, M. S.; Ross, J. W. Potassium Ion Specific Electrode with High Selectivity for Potassium over Sodium. Science 1970, 167, 987-988.

211

(345) Meuwis, K.; Boens, N.; De Schryver, F. C.; Gallay, J.; Vincent, M. Photophysics of the Fluorescent K+ Indicator Pbfi. Biophysical Journal 1995, 68, 2469-2473.

(346) Jezek, P.; Mahdi, F.; Garlid, K. D. Reconstitution of the Beef Heart and Rat Liver Mitochondrial K+/H+ (Na+/H+) Antiporter. Quantitation of K+ Transport with the Novel Fluorescent Probe, PBFI. Journal of Biological Chemistry 1990, 265, 10522- 10526.

(347) Crossley, R.; Goolamali, Z.; Sammes, P. G. Synthesis and Properties of a Potential Extracellular Fluorescent Probe for Potassium. Journal of the Chemical Society, Perkin Transactions 2 1994, 1615-1623.

(348) Sachs, J. R.; Welt, L. G. The Concentration Dependence of Active Potassium Transport in the Human Red Blood Cell. The Journal of Clinical Investigation 1967, 46, 65-76.

(349) Andersson, B.; Janson, V.; Behnam-Motlagh, P.; Henriksson, R.; Grankvist, K. Induction of Apoptosis by Intracellular Potassium Ion Depletion: Using the Fluorescent Dye PBFI in a 96-Well Plate Method in Cultured Lung Cancer Cells. Toxicology in Vitro 2006, 20, 986-994.

(350) Heathcote, R.; Howell, J. A. S.; Jennings, N.; Cartlidge, D.; Cobden, L.; Coles, S.; Hursthouse, M. Gold(I)-Isocyanide and Gold(I)-Carbene Complexes as Substrates for the Laser Decoration of Gold onto Ceramic Surfaces. Dalton Transactions 2007, 1309-1315.

(351) Sheik-Bahae, M.; Said, A. A.; Wei, T. H.; Hagan, D. J.; Van Stryland, E. W. Sensitive Measurement of Optical Nonlinearities Using a Single Beam. Quantum Electronics, IEEE Journal of 1990, 26, 760-769.

(352) Howard, J. B.; Rees, D. C. In Advances in Protein Chemistry; C.B. Anfinsen, J. T. E. F. M. R., David, S. E., Eds.; Academic Press: 1991; Vol. Volume 42, p 199-280.

(353) Aisen, P.; Wessling-Resnick, M.; Leibold, E. A. Iron Metabolism. Current Opinion in Chemical Biology 1999, 3, 200-206.

(354) Eisenstein, R. S. Iron Regulatory Protein and the Molecular Control of Mammalian Iron Metabolism. Annual Review of Nutrition 2000, 20, 627-662.

(355) Andrews, N. C. Disorders of Iron Metabolism. New England Journal of Medicine 1999, 341, 1986-1995.

(356) Touati, D. Iron and Oxidative Stress in Bacteria. Archives of Biochemistry and Biophysics 2000, 373, 1-6.

212

(357) Neilands, J. B. A Brief History of Iron Metabolism. Biol Metals 1991, 4, 1-6.

(358) Hsia, C. C. W. Respiratory Function of Hemoglobin. New England Journal of Medicine 1998, 338, 239-248.

(359) Rouault, T. A. The Role of Iron Regulatory Proteins in Mammalian Iron Homeostasis and Disease. Nat Chem Biol 2006, 2, 406-414.

(360) Netz, D. J. A.; Stümpfig, M.; Doré, C.; Mühlenhoff, U.; Pierik, A. J.; Lill, R. Tah18 Transfers Electrons to Dre2 in Cytosolic Iron-Sulfur Protein Biogenesis. Nat Chem Biol 2010, 6, 758-765.

(361) Lucas, M. F.; Rousseau, D. L.; Guallar, V. Electron Transfer Pathways in Cytochrome C Oxidase. Biochimica et Biophysica Acta (BBA) - Bioenergetics 2011, 1807, 1305-1313.

(362) Dai, S.; Schwendtmayer, C.; Schürmann, P.; Ramaswamy, S.; Eklund, H. Redox Signaling in Chloroplasts: Cleavage of Disulfides by an Iron-Sulfur Cluster. Science 2000, 287, 655-658.

(363) Beutler, E. "Pumping" Iron: The Proteins. Science 2004, 306, 2051-2053.

(364) Atkinson, A.; Winge, D. R. Metal Acquisition and Availability in the Mitochondria. Chemical Reviews 2009, 109, 4708-4721.

(365) Kaplan, C. D.; Kaplan, J. Iron Acquisition and Transcriptional Regulation. Chemical Reviews 2009, 109, 4536-4552.

(366) Theil, E. C.; Goss, D. J. Living with Iron (and Oxygen): Questions and Answers About Iron Homeostasis. Chemical Reviews 2009, 109, 4568-4579.

(367) Halliwell, B. Reactive Oxygen Species and the Central Nervous System. Journal of Neurochemistry 1992, 59, 1609-1623.

(368) Weinberg, E. D. The Role of Iron in Cancer. European journal of cancer prevention : the official journal of the European Cancer Prevention Organisation (ECP) 1996, 5, 19-36.

(369) Swaminathan, S.; Fonseca, V. A.; Alam, M. G.; Shah, S. V. The Role of Iron in Diabetes and Its Complications. Diabetes Care 2007, 30, 1926-1933.

(370) Galaris, D.; Skiada, V.; Barbouti, A. Redox Signaling and Cancer: The Role of "Labile" Iron. Cancer letters 2008, 266, 21-29.

213

(371) Gaeta, A.; Hider, R. C. The Crucial Role of Metal Ions in Neurodegeneration: The Basis for a Promising Therapeutic Strategy. British Journal of Pharmacology 2005, 146, 1041-1059.

(372) Molina-Holgado, F.; Hider, R.; Gaeta, A.; Williams, R.; Francis, P. Metals Ions and Neurodegeneration. Biometals 2007, 20, 639-654.

(373) Crichton, R. R.; Dexter, D. T.; Ward, R. J. Metal Based Neurodegenerative Diseases—from Molecular Mechanisms to Therapeutic Strategies. Coordination Chemistry Reviews 2008, 252, 1189-1199.

(374) Dornelles, A.; Garcia, V.; Lima, M. M.; Vedana, G.; Alcalde, L.; Bogo, M.; Schröder, N. Mrna Expression of Proteins Involved in Iron Homeostasis in Brain Regions Is Altered by Age and by Iron Overloading in the Neonatal Period. Neurochem Res 2010, 35, 564-571.

(375) Weizman, H.; Ardon, O.; Mester, B.; Libman, J.; Dwir, O.; Hadar, Y.; Chen, Y.; Shanzer, A. Fluorescently-Labeled Ferrichrome Analogs as Probes for Receptor- Mediated, Microbial Iron Uptake. Journal of the American Chemical Society 1996, 118, 12368-12375.

(376) Ma, Y.; Luo, W.; Quinn, P. J.; Liu, Z.; Hider, R. C. Design, Synthesis, Physicochemical Properties, and Evaluation of Novel Iron Chelators with Fluorescent Sensors. Journal of Medicinal Chemistry 2004, 47, 6349-6362.

(377) Wolf, C.; Mei, X.; Rokadia, H. K. Selective Detection of Fe(III) Ions in Aqueous Solution with a 1,8-Diacridylnaphthalene-Derived Fluorosensor. Tetrahedron Letters 2004, 45, 7867-7871.

(378) Ouchetto, H.; Dias, M.; Mornet, R.; Lesuisse, E.; Camadro, J. M. A New Route to Trihydroxamate-Containing Artificial Siderophores and Synthesis of a New Fluorescent Probe. Bioorganic & Medicinal Chemistry 2005, 13, 1799-1803.

(379) Qu, X.; Liu, Q.; Ji, X.; Chen, H.; Zhou, Z.; Shen, Z. Enhancing the Stokes' Shift of Bodipy Dyes Via through-Bond Energy Transfer and Its Application for Fe3+- Detection in Live Cell Imaging. Chemical Communications 2012, 48, 4600-4602.

(380) Lee, M. H.; Giap, T. V.; Kim, S. H.; Lee, Y. H.; Kang, C.; Kim, J. S. A Novel Strategy to Selectively Detect Fe(III) in Aqueous Media Driven by Hydrolysis of a Rhodamine 6g Schiff Base. Chemical Communications 2010, 46, 1407-1409.

(381) Wang, B.; Hai, J.; Liu, Z.; Wang, Q.; Yang, Z.; Sun, S. Selective Detection of Iron(III) by Rhodamine-Modified Fe3o4 Nanoparticles. Angewandte Chemie International Edition 2010, 49, 4576-4579.

214

(382) Chen, W.-d.; Gong, W.-t.; Ye, Z.-q.; Lin, Y.; Ning, G.-l. Fret-Based Ratiometric Fluorescent Probes for Selective Fe3+ Sensing and Their Applications in Mitochondria. Dalton Transactions 2013, 42, 10093-10096.

(383) Qiu, L.; Zhu, C.; Chen, H.; Hu, M.; He, W.; Guo, Z. A Turn-on Fluorescent Fe3+ Sensor Derived from an Anthracene-Bearing Bisdiene Macrocycle and Its Intracellular Imaging Application. Chemical Communications 2014, 50, 4631-4634.

(384) Bricks, J. L.; Kovalchuk, A.; Trieflinger, C.; Nofz, M.; Büschel, M.; Tolmachev, A. I.; Daub, J.; Rurack, K. On the Development of Sensor Molecules That Display FeIII- Amplified Fluorescence. Journal of the American Chemical Society 2005, 127, 13522-13529.

(385) Clapham, D. E. Calcium Signaling. Cell, 131, 1047-1058.

(386) Palmer, A. E. Expanding the Repertoire of Fluorescent Calcium Sensors. ACS Chemical Biology 2009, 4, 157-159.

(387) Giovannucci, E.; Rimm, E. B.; Wolk, A.; Ascherio, A.; Stampfer, M. J.; Colditz, G. A.; Willett, W. C. Calcium and Fructose Intake in Relation to Risk of Prostate Cancer. Cancer Research 1998, 58, 442-447.

(388) Tsien, R. Y. New Calcium Indicators and Buffers with High Selectivity against Magnesium and Protons: Design, Synthesis, and Properties of Prototype Structures. Biochemistry 1980, 19, 2396-2404.

(389) Rusakov, D. A.; Fine, A. Extracellular Ca2+ Depletion Contributes to Fast Activity- Dependent Modulation of Synaptic Transmission in the Brain. Neuron 2003, 37, 287-297.

(390) Collot, M.; Loukou, C.; Yakovlev, A. V.; Wilms, C. D.; Li, D.; Evrard, A.; Zamaleeva, A.; Bourdieu, L.; Léger, J.-F.; Ropert, N.; Eilers, J.; Oheim, M.; Feltz, A.; Mallet, J.-M. Calcium Rubies: A Family of Red-Emitting Functionalizable Indicators Suitable for Two-Photon Ca2+ Imaging. Journal of the American Chemical Society 2012, 134, 14923-14931.

215