Dehumidifier SERVICE MANUAL
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
DOAS Enthalpy Wheel (EW) Issues
DOAS Enthalpy Wheel (EW) Issues: 1. Is it required for DOAS? Yes for all practical purposes in the USA. Both ASHRAE Std. 90.1 and ASHRAE’s new Standard for the Design Of High Performance Green Buildings (189.1) require a 60% effective total energy recovery (TER) device for even the smallest systems in the moist USA--located primarily east of the continental divide as illustrated below: 2. Life and durability. The following link provides useful information, particularly concerning the life expectancy. http://www.thermotech-usa.com/tech_heatwheel 3. Purge, a basic description of how it works is at the following link: http://www.thermotech-usa.com/tech_purge . The presence of the purge requires an increase in air flow beyond the desired supply air delivery requirement, increasing fan energy use. Therefore unless absolutely needed for air quality reasons (most all-air systems in commercial facilities recirculate up to 80% of the air—so what is a few percent recirculation at the EW going to hurt) purge should be avoided. 4. Seal leakage is an equally important issue. Like purge, seal leakage should be minimized for fan energy savings as well. This requires wheels with tough wear resistant and very planar faces. And the seals must be very close fitting. 5. Dirty Socks Odor Syndrome: Published references for EW occurrences are not readily available at this time. However the syndrome occurrences have only been reported where a silica gel desiccant on non-aluminum matrix substrate EW is used. There have not been reports of this syndrome problem for applications where a molecular sieve (zeolite) desiccant on an aluminum substrate EW is used. -
Bimetal Disc Thermostat APPLICATION NOTES
Bimetal Disc Thermostat APPLICATION NOTES Operating Principle Bimetal disc thermostats are thermally actuated switches. When the bimetal disc is exposed to its predetermined calibration temperature, it snaps and either opens or closes a set of contacts. This breaks or completes the electrical circuit that has been applied to the thermostat. There are three basic types of thermostat switch actions: • Automatic Reset: This type of control can be built to either open or close its electrical contacts as the temperature increases. Once the temperature of the bimetal disc has returned to the specified reset temperature, the contacts will automatically return to their original state. • Manual Reset: This type of control is available only with electrical contacts that open as the temperature increases. The contacts may be reset by manually pushing on the reset button after the control has cooled below the open temperature calibration. • Single Operation: This type of control is available only with electrical contacts that open as the temperature increases. Once the electrical contacts have opened, they will not automatically reclose unless the ambient that the disc senses drops to a temperature well below room temperature (typically below -31°F). 1 Temperature Sensing & Response Many factors can affect how a thermostat senses and responds to temperature changes in an application. Typical factors include, but are not limited to, the following: • Mass of the thermostat • Switch head ambient temperature. The “switch head” is the plastic or ceramic body and terminal area of the thermostat. It does not include the sensing area. Switch head portion of thermostat Sensing surface of thermostat Figure 1 – Thermostat Construction • Air flow across the sensing surface or sensing area. -
Cd60 Dehumidifier Specifications
To Buy: Visit www.sylvane.com or call (800) 934-9194 For Product Support: Contact Ebac USA at (757) 873 6800 CD60 DEHUMIDIFIER SPECIFICATIONS Specifications CD60 Features CD60 Model No. 10264FR-US Model No. 10264FR-US Height 17” (432mm) On/Off Control Width 20” (514mm) Electronic Defrost Control Depth 14” (356mm) Compressor Type Rotary Weight 80 lbs (36kg) Fitted Mains Plug Voltage 110 V Free Standing Adjustable Feet Phase 1 Remote Humidistat Frequency 60 Hz Adjustable Control Humidistat Current 7 A Hot Gas Defrost System Power 880W Hours Run Meter Airflow 360cfm (608m3/hr) High Capacity Condensate Pump Noise Level 57 dba Quick Disconnect Hose Coupling Refrigerant R407c 25’ Length of PVC Drain Hose Effective Volume 8,369 cu.ft (237m3) Epoxy Powder Coating Typical Extraction 56 ppd Minimum Operating Temperature 33°F (1°C) Maximum Operating Temperature 95°F (35°C) APPLICATION The EIPL CD60 commercial / industrial dehumidifier was designed to provide energy efficient humidity control in a wide range of applications including offices, laboratories, apartments, storage areas, restaurants, bars, museums, locker rooms, computer, telecommunication rooms and basements. It is a quiet, high efficiency, high capacity unit designed to suit your HVAC needs. KEY DESIGN FEATURES • Adjustable control humidistat to maintain the level of dryness • A convenient drain point for condensate collection of hose attachment • EIP’s unique “Hot Gas” defrosting feature which automatically melts away frost buildup providing effective operation at low ambient temperatures • Rugged, epoxy powder-coated steel chassis and housing. • Hours run meter • Simplicity of installation and operation with a standard 115V plug • Extra long power cord. -
Model 70007000
M ModelModel 70007000 Installation/Operating Instructions # 010921025 2 Model 7000 Flow Through Humidifier FREQUENTLY ASKED QUESTIONS your furnace is running and in heating mode. 24 hours of humidifier operation may take 3 days to complete. Question: Why use a flow-through style humidifier rather Question: How much water does this humidifier use? than a drum style humidifier? Answer: This humidifier incorporates a restrictor which Answer: This will depend on several factors including size of meters the amount of water supplied to the unit. In the home, style of furnace, and size of ducting; as well as personal average home the unit will use totally 56 US gallons (47 preference. However in order to use this model flow through Imperial gallons, 212 Litres) of water per 24 hours of you will require at least 10" wide ducting where as our drum operation. styles will fit on 8" ducting. Comment: As mentioned above 24 hours of operation refers Comment: Flow-through and rotating-drum style evaporative to humidifier operation, the 24 hours operating time may take furnace humidifiers will safely and efficiently humidify 90% of 3 days to complete. When Compared to the water consumed homes which use forced air heating. As a manufacturer of during the average shower (3 to 5 gallons per minute) the total both styles there are pro’s and con’s to be considered when amount of water consumed to humidify your home is not that choosing a type of humidifier. A drum style humidifier is much. typically 100% efficient in its use of water, meaning all the water it uses will be delivered to the air. -
Indoor Air Quality Products Offering Healthy Home Solutions
Indoor Air Quality Products Offering Healthy Home Solutions Carrier clears the air for enhanced indoor comfort What You Can Expect From Carrier Innovation, efficiency, quality: Our Carrier® Healthy Home Solutions offers superior control over the quality of your indoor air and as a result, improved comfort. From air purification and filtration to humidity control, ventilation and more, these products represent the Carrier quality, environmental stewardship and lasting durability that have endured for more than a century. In 1902, that’s the year a humble but determined engineer solved one of mankind’s most elusive challenges – controlling indoor comfort. A leading engineer of his day, Dr. Willis Carrier would file more than 80 patents over the course of his career. His genius would enable incredible advancements in health care, manufacturing processes, food preservations, art and historical conservation, indoor comfort and much more. Carrier’s foresight changed the world forever and paved the way for over a century of once-impossible innovations. Designed with Your Comfort in Mind Carrier® Healthy Home Solutions represents years of design, development and testing with one goal in mind – maximizing your family’s comfort. Along the way, we have taken the lead with new technologies that deliver the superior performance you demand while staying ahead of industry trends and global initiatives. With innovations like Captures & Kills™ technology and superior humidity and airflow control, whatever your need, Carrier has a solution that’s perfectly tailored for you. 2 Ready to Clear the Air? The EPA has found that indoor levels of many air pollutants are often higher than outdoor levels. -
Guide for Air Conditioning, Refrigeration, and Help the Student
DOCUMENT RESUME ED 251 645 CE 040 232 AUTHOR Henderson, William Edward, Jr., Ed. TITLE Art::culated, Performance-Based Instruction Objectives Guide for Air Conditioning, Refrigeration, and Heating. Volume II(Second Year). INSTITUTION Greenville County School District, Greenville, S.C.; Greenville Technical Coll., S. PUB DATE Oct 84 NOTE 374p.; Prepared by the Articulation Program Task Force Committee for Air Conditioning, Refrigeration, and Heating. PUB TYPE Guides Clasrroom Use Guides (For Teachers) (052) EDRS PRICE MF01/PC15 Plus Postage. DESCRIPTO. *Air Conditioning; Behavioral Objectives; Competency Based Education; Curriculum Guides; *Equipment Maintenance; Fuels; Jrade 12; *Heating; High Schools; Job Skills; Le.,zning Activities; *Refrigeration; Secondary Education; Solar Energy; Trade and Industrial Education; Units of Study; *Ventilation ABSTRACT This articulation guide contains 17 units of instruction for the second year of a two-year vocational program designed to prepare the high school graduate to install, maintain, and repair various types of residential and commercial heating, air conditioning, and refrigeration equipment. The units are designed to help the student to expand and apply the basic knowledge already mastered and to learn new principles and techniques and to prepare him/her for entry-level work as an apprentice. The seventeen units cover aid conditioning calculations (psychrometrics,residential heat loss and heat gain, duct design and sizing and air treatment); troubleshooting and servicing residential air conditioners; commercial refrigeration; commercial air conditioning; heating systems (electrical resistance heating, heat pumps, gas heating, oil heating, hydronics, solar heating systems); automotive air conditioner maintenance/repair; estimating and planning heating, ventilation, and air conditioning jobs; customer relations; and shop projects. -
Display Fault/Error Codes Pf E1 E2 Diagnostic Guide
TECH SHEET - DO NOT DISCARD PAGE 1 IMPORTANT Electrical Shock Hazard Electrostatic Discharge (ESD) Sensitive Electronics Disconnect power before servicing. ESD problems are present everywhere. ESD may damage or weaken the machine control electronics. The new control assembly may appear to work well after Replace all parts and panels before repair is finished, but failure may occur at a later date due to ESD stress. operating. ■ Use an anti-static wrist strap. Connect wrist strap to green ground Failure to do so can result in death connection point or unpainted metal in the appliance or electrical shock. -OR- Touch your finger repeatedly to a green ground connection point or unpainted metal in the appliance. DIAGNOSTIC GUIDE ■ Before removing the part from its package, touch the anti-static bag to a green ground connection point or unpainted metal in the appliance. Before servicing, check the following: ■ Avoid touching electronic parts or terminal contacts; handle machine control ■ Is the power cord firmly plugged into a electronics by edges only. live circuit with proper voltage? ■ When repackaging failed machine control electronics in anti-static bag, ■ Has a household fuse blown or circuit observe above instructions. breaker tripped? Time delay fuse? ■ Is dryer vent properly installed and clear of lint or obstructions? If unsuccessful entry into diagnostic them to the part numbers in the ■ All tests/checks should be made with a mode, actions can be taken for Components Table on page 2. See VOMorDVM having a sensitivity of specific indications: Accessing & Removing the Electronic 20,000 ohms per volt DC or greater. Assemblies, page 10. -
Model 1830, 1850 & 1850W Dehumidifier Owner's Manual
Model 1830, 1850 & 1850W Dehumidifier Owner’s Manual PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER Installed by: _________________________________ Installer Phone: _______________________ Date Installed: _______________ ON/OFF button Up/Down Dehumidifer Control Outlet used to turn buttons used to dehumidifier on change humidity and off setting MODE button used for optional ventilation feature Inlet Filter Access Drain Power Door Switch 90-1874 WHOLE HOME Dehumidification The Aprilaire® Dehumidifier controls the humidity level in your entire home. A powerful blower inside the dehumidifier draws air into the cabinet, filters the air and removes moisture, then discharges the dry air into the HVAC system or dedicated area of the home. Inside the cabinet, a sealed refrigeration system removes moisture by moving the air through a series of tubes and fins that are kept colder than the dew point of the incoming air. The dew point is the temperature at which moisture in the air will condense, much like what occurs on the outside of a cold glass on a hot summer day. The condensed moisture drips into the dehumidifier drain pan to a drain tube routed to the nearest floor drain or condensate pump. After the moisture is removed, the air moves through a second coil where it is reheated before being sent back into the home. The air leaving the dehumidifier will be warmer and drier than the air entering the dehumidifier. SETTING THE DESIRED HUMIDITY LEVEL The dehumidifier on-board control will display the humidity setting when not running, and ENERGY SavinGS TIPS displays the measured humidity when running. Energy Savings Tip #1: Adjust the humidity setting to be as high as is comfortable to reduce dehumidifier run time. -
DEHUMIDIFIER with BUILT-IN PUMP
DEHUMIDIFIER with BUILT-IN PUMP MODELS: SD-52PE / SD-72PE INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference. CONTENTS SAFETY PRECAUTUIONS…...……………………………………………………………2 ELECTRICAL INFORMATION .……………………………………………………………3 CONTROL PANEL ….………………………………………………………………………4 FEATURES ………….……………………………………………………………………….5 IDENTIFICATION OF PARTS …………………………….……………………………….6 OPERATING THE UNIT ………..………………………….……………………………….7 WATER DRAINAGE ……….………..…………………………………………………….8 CARE AND MAINTENANCE ………..………………………………………………….10 TECHNICAL SPECIFICATIONS ……………………….………………………………11 TROUBLE SHOOTING …………………………………………………………………..11 SOCIABLE REMARK DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at free of charge to the user. B) The manufacturer will take back the old appliance for disposal at free of charge to the user. C) As old products contain valuable resources, they may be sold to scrap metal dealers. Wild disposal of waste in forest and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain. 1 BEFORE YOU USE YOUR DEHUMIDIFIER , PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY. SAFETY PRECAUTIONS To prevent injury and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damages. The seriousness is classified by the following indications: WARNING: This symbol indicates the possibility of death or serious injury. CAUTION: This symbol indicates the possibility of injury or damage to property. ------------------------------------------ WARNING --------------------------------------------------- 1. Do not exceed the rating of the power outlet or connection device. -
Single Pole Humidity Sensor and Fan Controller Cat
Single Pole Humidity Sensor and Fan Controller Cat. Nos. IPHS5 - INDOOR USE ONLY 120VAC, 60Hz - Single Pole Only Incandescent: 600W - MLV/Fluorescent: 400VA - LED/CFL: 150W - Fan: 1/6Hp WARNINGS CAUTIONS • TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER • Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! liquids. • TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to • No user serviceable components. DO NOT attempt to service or repair. control a receptacle, or a load in excess of the specified rating. • Use this device WITH COPPER CLAD WIRE ONLY. • To be installed and/or used in accordance with electrical codes and regulations. • If you are not sure about any part of these instructions, consult an electrician. DI-000-IPHS5-02B INSTALLATION ENGLISH Features Location You Will Need: The humidity sensor and fan controller senses the humidity of your bathroom • Slotted/Phillips screwdriver • For bathroom applications the device should be placed and turns your bath fan or fan/light on when the humidity gets too high, • Pencil reducing condensation in your bathroom and increasing ventilation when used at a level to detect steam. Placing the detector directly in other household spaces. above a heater or near drafts is not recommended. • Electrical tape • Compatible with Incandescent, LED, CFL and Fluorescent loads when • NOTE: DO NOT use to control a fan/light combination • Cutters used with combination fan and light fixtures. where the fan/light is the only means of illumination. -
Reference Material
Atlanta | Corporate HQ Cleveland Houston Phoenix REFERENCE MATERIAL CONTENTS 188 Limited Warranty Certificate 189 Ballast Specifications 193 Cross Reference Guide 196 Glossary of Terms 203 Quality Assurance We deliver like nobody’s business. Said another way, our shipping capabilities are unbeatable. Our strategically-located distribution centers in Atlanta, Cleveland, Houston and Phoenix allow us to meet ambitious delivery requirements, and low minimum order and freight requirements. In fact, we will drop ship at no additional charge, ship directly to the job site, and even provide same-day shipping on orders placed by 2:00pm local warehouse time. ELECTRONIC BALLAST SPECIFICATIONS Fluorescent Electronic Ballast shall have a Lamp Current Crest Factor of <1.7 in accordance with ANSI C82.1. Ballast shall withstand line voltage transients and surges as specified in ANSI standard C62.41-1991. Ballast shall have an Underwriters Laboratories certification for operation in the US and either an Underwriters Laboratories or Canadian Standards Association certification for operation in Canada. Electronic Sign Ballast shall comply with the EMI and RFI limits of the code of Federal Regulations, Title 47, Part 18C for Non-Consumer equipment. Ballast shall operate in the range of 50-60Hz input frequency. Compact Fluorescent Ballast shall operate at a maximum of 18 feet remote mounting distance for primary lamp. For energy saving reduced wattages lamps, remote mounting distances will be shorter. Ballast shall operate at a frequency of 20-40 kHz. Ballast shall contain potting compound in order to protect from moisture, dissipate heat and provide stability. HID Electronic All ProFormance ballasts shall have a power factor of 0.98 or better on the primary lamp configuration. -
Dehumidifiers' Common Phenomenon and Troubleshooting Manual
Dehumidifiers’ Common Phenomenon and Troubleshooting Manual AlorAir Solutions,Inc Web: www.alorair.com E-mail: [email protected] Restoration&Moisture&Ventilation Dehumidifiers’ Common Phenomenon and Troubleshooting Manual Welcome to Alorair company. Alorair focuses mainly on Dehumidifier’s Common Phenomenon and Troubleshooting.. inner air quality solutions with quite professional dehumidifiers’ LGR ............................................................... .. PAGE 01-03 technology, SLGR technology, super efficient air mover and air scrubber. As the staff train file and customers after-sale instruction, Dehumidifiers’ Common Phenomenon and Troubleshooting manual aims to bring a serial of expertise suggestions in facing with confused Error codes............................................................................ dehumidifier operation errors. ................................................................ PAGE 03-06 This manual contains three parts: 1).Dehumidifiers’ Common Phenomenon and Troubleshooting FAQ........................................................................................ 2). Error codes .................................................................. PAGE 06 3). FAQ Please refer to according contents for your reference needs. Humidity sensor failure Replace the humidity sensor Dehumidifiers’ Common Phenomenon Frequent starting of The humidity sensor is influenced by the moisture Adjust the position of the sensor to the right unit from evaporator position to avoid interference and Troubleshooting Humidity