Integrated Rectifier Monitoring, Control, and Interruption Integrated Rectifier Monitoring, Control, and Interruption
Total Page:16
File Type:pdf, Size:1020Kb
Farwest Corrosion Control Company www.farwestcorrosion.com Corrosion Control Products Company www.ccpco.com CellularRMU ™ CellularRMU ™ Integrated Rectifier Monitoring, Control, and Interruption Interruption and Control, Monitoring, Rectifier Integrated Wireless Internet Monitoring of Cathodic Protection Rectifiers FEATURES WIRELESS INTERNET-BASED RECTIFIER • Monitor CP rectifier operation – alarms sent via MONITORING, CONTROL & INTERRUPTION email, fax, pager NTG’s latest product, the CellularRMU™, provides complete rectifier monitoring, control, and interruption in a single product. It monitors • Report voltage, current, pipe-to-soil potential, voltage, current, and discrete signals (e.g. intrusion alarm, pump equipment status at programmed times status, etc.). It can also output a signal to remotely adjust a rectifier output, control a relay, and trigger GPS-synchronized rectifier • GPS Interruption – activate, adjust, and verify interruption, all without travel to the remote site. interruption over the Internet – lower the cost of www.scadanet.net surveys • 2-Way communication allows the user to poll units for “on-demand” status and readings • Remotely turn rectifiers on and off • Up to 5 analog and/or digital inputs • One analog and one digital output For Sales & Information, Call Toll Free: (888) 532-7937 Farwest Corrosion Control Company www.farwestcorrosion.com Corrosion Control Products Company ™www.ccpco.com Integrated Rectifier Monitoring, Control, and Interruption CellularRMU CellularRMUThe CellularRMU™ is designed to do several important jobs for pipeline CellularRMU ™ Specifications corrosion technicians: Modular Input/Outputs: Up to 5 input or output modules – user specified 1) Monitor CP rectifier operation and report rectifier voltage, current, and High Voltage Input Module: +/-200 Vdc; Accuracy: < 1%; Resolution: 10 mV anomalies Low Voltage Input Module: +/- 100 mVdc; Accuracy: < 1% 2) Automatically take readings per programmed schedules and transmit them to Resolution: 100 uV ™ a database for analysis and compliance reporting Interruption and Control, Monitoring, Rectifier Integrated Digital Input Module: Reads dry contact switch closure; 3) Provide GPS-synchronized rectifier interruption for Close Interval Surveys switches at 500Ω (with the optional Rectifier Interruption Module [RIM] installed) Voltage Output Module: Output voltage range: 0-10 or +/- 5 Vdc; 4) Control any relay-activated equipment (pump, generator, lighting, etc.) 2 mV resolution It performs these tasks accurately, reliably, and inexpensively. Digital Output (normally open): SPST relay contact; rated for 6A at 24Vdc or 120Vac Optional Built-in GPS-Synchronized Isolation: Relay isolated from structure to 1500V, Rectifier Interruption except during read The CellularRMU™ can be fitted with a GPS-synchronized current interrupter Backup Battery (optional): 12 V sealed lead-acid, internally recharged, that greatly simplifies field surveys and reduces their associated expense. Via 10 hr. operation during power loss the Internet, the user can select which rectifiers should start interrupting per a GPS Synchronized Interruption: Built-in Trimble GPS receiver provides programmed duty cycle and schedule. They will then start, stop, and interrupt in time synchronization unison per the precise timing of the internal GPS clocks. Verification of interruption Two programmable interruption cycles, and reprogramming of the interruption duty cycle can be done over the Internet. remotely selectable and reprogrammable Control Pumps, Valves, Other Equipment Programmable scheduling (start & stop time-of-day; # days) The CellularRMU™ features a single SPST relay contact output for controlling Activate and deactivate interruption and switch-activated equipment. It also has an optional DC Voltage output card rectifier on/off over Internet – positively for analog control of rectifier voltage or any other analog voltage-controlled verified via ScadaNET Network parameter. Rectifier Switching Assembly: Mercury switch relay (specify 60A or 100A) Reliable Operation (or 0-12 Vdc / 100 mA drive available for The CellularRMU™ is designed to handle the rugged pipeline field environment. external solid state relay) The unit is typically installed in the rectifier enclosure, or, optionally, in is own Communications: Cellemetry® AMPS cellular control NEMA outdoor enclosure. It is rated to operate from -22 to +158° F. channel; 1.2 W transmit power Antenna options: Low profile, 3dB gain, cellular radome Inexpensive Operating Cost antenna (42-0005-00) A typical CellularRMU™, reporting weekly and used occasionally for automatic Combination GPS/cellular radome antenna rectifier interruption, will incur messaging costs of about $4.00 per month. There (42-0016-00) is no minimum monthly fee – users pay only for actual messages incurred. GPS antenna (40-0015-00) Export Readings to CP Data Management High-gain (+9dB) YAGI cellular antenna (42-0007-00) and Compliance Software Size: 5” H x 8”W x 2.5”D (13 x 20.3 x 6.4 cm); Data is available around the clock from NTG’s secure ScadaNET Network™ website 5 lbs (2.2 kg) via protected user login. Each user can see, at a glance, the reading history and status Mounting: Flange mount of all the NTG units within their control. Historic data can easily be downloaded Optional Outdoor Enclosure: NEMA 4X (9”H x 11”W x 6”D) Specify: Fiberglass, into a spreadsheet for analysis, or the user can select the desired voltage and steel, or aluminum (Houses battery, monitor, wiring harness, power switch, GPS/ current readings and easily import them into popular CP Data Management software cellular antenna, Power Conditioning module) packages. This greatly simplifies the user’s reporting and data management tasks. Temperature Range: -22° to 158° F (-30° to 70°C) operating and storage The Strength of an Experienced, Humidity: 0 to 100% Financially Strong Supplier Over 10 years ago, NTG’s technical staff introduced the first cellular control Optional Accessories NTG Part Number channel remote monitors into the cathodic protection market while part of AC Voltage probe 01-3340-00 Labarge, Inc. Today NTG is owned by Elecsys, Inc., a publicly traded electronics (detects presence of incoming AC line voltage) company (symbol ASY). Backed by the financial strength of Elecsys, NTG is Stepdown transformer (115 Vac to 14 Vac) 24-0014-12 committed to long term customer support and new product development that will Power Conditioning module 01-3320-00 continue to bring innovative, cost-effective solutions to its customers. (additional surge protection for power inputs) www.scadanet.net For more information, contact: © Copyright 2006, Network Technologies Group, Inc. ScadaNET Network, CellularRTU, CellularRMU, P2S Pipe-to-Soil Monitor, Cpi, and ConfigRTU are trademarks of Network Technologies Group, Inc. Cellemetry is a registered trademark of Cellemetry, LLC Covered under one or more of the following patents – 6,288.432 6,774,814, 6,618,394 6,393,298 Other patents pending. Product specifications are subject to change without notice. CellularRMU 3.1 03/06/06 For Sales & Information, Call Toll Free: (888) 532-7937.