Integrated Rectifier Monitoring, Control, and Interruption Integrated Rectifier Monitoring, Control, and Interruption

Total Page:16

File Type:pdf, Size:1020Kb

Integrated Rectifier Monitoring, Control, and Interruption Integrated Rectifier Monitoring, Control, and Interruption Farwest Corrosion Control Company www.farwestcorrosion.com Corrosion Control Products Company www.ccpco.com CellularRMU ™ CellularRMU ™ Integrated Rectifier Monitoring, Control, and Interruption Interruption and Control, Monitoring, Rectifier Integrated Wireless Internet Monitoring of Cathodic Protection Rectifiers FEATURES WIRELESS INTERNET-BASED RECTIFIER • Monitor CP rectifier operation – alarms sent via MONITORING, CONTROL & INTERRUPTION email, fax, pager NTG’s latest product, the CellularRMU™, provides complete rectifier monitoring, control, and interruption in a single product. It monitors • Report voltage, current, pipe-to-soil potential, voltage, current, and discrete signals (e.g. intrusion alarm, pump equipment status at programmed times status, etc.). It can also output a signal to remotely adjust a rectifier output, control a relay, and trigger GPS-synchronized rectifier • GPS Interruption – activate, adjust, and verify interruption, all without travel to the remote site. interruption over the Internet – lower the cost of www.scadanet.net surveys • 2-Way communication allows the user to poll units for “on-demand” status and readings • Remotely turn rectifiers on and off • Up to 5 analog and/or digital inputs • One analog and one digital output For Sales & Information, Call Toll Free: (888) 532-7937 Farwest Corrosion Control Company www.farwestcorrosion.com Corrosion Control Products Company ™www.ccpco.com Integrated Rectifier Monitoring, Control, and Interruption CellularRMU CellularRMUThe CellularRMU™ is designed to do several important jobs for pipeline CellularRMU ™ Specifications corrosion technicians: Modular Input/Outputs: Up to 5 input or output modules – user specified 1) Monitor CP rectifier operation and report rectifier voltage, current, and High Voltage Input Module: +/-200 Vdc; Accuracy: < 1%; Resolution: 10 mV anomalies Low Voltage Input Module: +/- 100 mVdc; Accuracy: < 1% 2) Automatically take readings per programmed schedules and transmit them to Resolution: 100 uV ™ a database for analysis and compliance reporting Interruption and Control, Monitoring, Rectifier Integrated Digital Input Module: Reads dry contact switch closure; 3) Provide GPS-synchronized rectifier interruption for Close Interval Surveys switches at 500Ω (with the optional Rectifier Interruption Module [RIM] installed) Voltage Output Module: Output voltage range: 0-10 or +/- 5 Vdc; 4) Control any relay-activated equipment (pump, generator, lighting, etc.) 2 mV resolution It performs these tasks accurately, reliably, and inexpensively. Digital Output (normally open): SPST relay contact; rated for 6A at 24Vdc or 120Vac Optional Built-in GPS-Synchronized Isolation: Relay isolated from structure to 1500V, Rectifier Interruption except during read The CellularRMU™ can be fitted with a GPS-synchronized current interrupter Backup Battery (optional): 12 V sealed lead-acid, internally recharged, that greatly simplifies field surveys and reduces their associated expense. Via 10 hr. operation during power loss the Internet, the user can select which rectifiers should start interrupting per a GPS Synchronized Interruption: Built-in Trimble GPS receiver provides programmed duty cycle and schedule. They will then start, stop, and interrupt in time synchronization unison per the precise timing of the internal GPS clocks. Verification of interruption Two programmable interruption cycles, and reprogramming of the interruption duty cycle can be done over the Internet. remotely selectable and reprogrammable Control Pumps, Valves, Other Equipment Programmable scheduling (start & stop time-of-day; # days) The CellularRMU™ features a single SPST relay contact output for controlling Activate and deactivate interruption and switch-activated equipment. It also has an optional DC Voltage output card rectifier on/off over Internet – positively for analog control of rectifier voltage or any other analog voltage-controlled verified via ScadaNET Network parameter. Rectifier Switching Assembly: Mercury switch relay (specify 60A or 100A) Reliable Operation (or 0-12 Vdc / 100 mA drive available for The CellularRMU™ is designed to handle the rugged pipeline field environment. external solid state relay) The unit is typically installed in the rectifier enclosure, or, optionally, in is own Communications: Cellemetry® AMPS cellular control NEMA outdoor enclosure. It is rated to operate from -22 to +158° F. channel; 1.2 W transmit power Antenna options: Low profile, 3dB gain, cellular radome Inexpensive Operating Cost antenna (42-0005-00) A typical CellularRMU™, reporting weekly and used occasionally for automatic Combination GPS/cellular radome antenna rectifier interruption, will incur messaging costs of about $4.00 per month. There (42-0016-00) is no minimum monthly fee – users pay only for actual messages incurred. GPS antenna (40-0015-00) Export Readings to CP Data Management High-gain (+9dB) YAGI cellular antenna (42-0007-00) and Compliance Software Size: 5” H x 8”W x 2.5”D (13 x 20.3 x 6.4 cm); Data is available around the clock from NTG’s secure ScadaNET Network™ website 5 lbs (2.2 kg) via protected user login. Each user can see, at a glance, the reading history and status Mounting: Flange mount of all the NTG units within their control. Historic data can easily be downloaded Optional Outdoor Enclosure: NEMA 4X (9”H x 11”W x 6”D) Specify: Fiberglass, into a spreadsheet for analysis, or the user can select the desired voltage and steel, or aluminum (Houses battery, monitor, wiring harness, power switch, GPS/ current readings and easily import them into popular CP Data Management software cellular antenna, Power Conditioning module) packages. This greatly simplifies the user’s reporting and data management tasks. Temperature Range: -22° to 158° F (-30° to 70°C) operating and storage The Strength of an Experienced, Humidity: 0 to 100% Financially Strong Supplier Over 10 years ago, NTG’s technical staff introduced the first cellular control Optional Accessories NTG Part Number channel remote monitors into the cathodic protection market while part of AC Voltage probe 01-3340-00 Labarge, Inc. Today NTG is owned by Elecsys, Inc., a publicly traded electronics (detects presence of incoming AC line voltage) company (symbol ASY). Backed by the financial strength of Elecsys, NTG is Stepdown transformer (115 Vac to 14 Vac) 24-0014-12 committed to long term customer support and new product development that will Power Conditioning module 01-3320-00 continue to bring innovative, cost-effective solutions to its customers. (additional surge protection for power inputs) www.scadanet.net For more information, contact: © Copyright 2006, Network Technologies Group, Inc. ScadaNET Network, CellularRTU, CellularRMU, P2S Pipe-to-Soil Monitor, Cpi, and ConfigRTU are trademarks of Network Technologies Group, Inc. Cellemetry is a registered trademark of Cellemetry, LLC Covered under one or more of the following patents – 6,288.432 6,774,814, 6,618,394 6,393,298 Other patents pending. Product specifications are subject to change without notice. CellularRMU 3.1 03/06/06 For Sales & Information, Call Toll Free: (888) 532-7937.
Recommended publications
  • MM2EMD L7.Pdf
    University of Nottingham Electromechanical devices MM2EMD Lecture 7 – Transistors - Switching high voltage things on with a low voltage Dr. Roderick MacKenzie [email protected] Summer 2015 @rcimackenzie Released under Outline of the lecture •No recap of last lecture :) •Transistor basics •Relays (Mechanical transistor) •NPN Bipolar Junction Transistors •PNP Bipolar Junction Transistors •MOSFETs •Push pull pairs to drive MOSFETs •One last thing •Summary 2 Roderick MacKenzie MM2EMD Electromechanical devices Outline of the lecture •No recap of last lecture :) •Transistor basics •Relays (Mechanical transistor) •NPN Bipolar Junction Transistors •PNP Bipolar Junction Transistors •MOSFETs •Push pull pairs to drive MOSFETs •One last thing •Summary 3 Roderick MacKenzie MM2EMD Electromechanical devices Roderick MacKenzie Roderick electrical devices suchas motors. high voltage control electronics • This lecture is making low voltageThis lecture Think back to lecture 1. lecture Think backto Dave Jones Smart Electronic Circuits (low voltage) Circuits voltage) (high S.J. de Waard Simple Simple Electrical MM2EMD Electromechanical devices 4 Think about an AND gate chip And gate Biro •Look at the tiny thin pins which are used to carry current in and out of the chip. •These pins can supply 25 mA @ 5V at the most. 5 Roderick MacKenzie MM2EMD Electromechanical devices But why is this? i •If we take the top off the chip h p o with acid. G ● Look how much small the actual chip is and look at the tiny bond wires (25 mA @ 5V max!!!) 6 Roderick MacKenzie MM2EMD Electromechanical devices Roderick MacKenzie Roderick 500 V • It needsIt Now think about this motor. this about Now think to run.to 10 Amps 10 at CMBJ the current.
    [Show full text]
  • What Are Electronic Timing Relays? a Relay Is an Electromagnetic Switch Which Operates on a Small Electric Current
    What Do You Know About Electronic Timing Relays? There are certain components that form the core of the modern control systems. One such important component used in many applications is an Electronic Timing Relay (ETR). Let us start by understanding some basics. What are Electronic Timing Relays? A relay is an electromagnetic switch which operates on a small electric current. These switches are used to turn on or off a circuit of higher amperage. When electricity is applied, the electromagnetic coil causes the armature to move, opening or closing the contacts, controlling the flow of electricity from a high current source connected to the load side of the relay. Relays act as bridges that activate larger currents using smaller ones. This allows you to use a relay to safely switch on and off different devices. An Electronic Timing Relay has circuitry integrated which controls the armature motion upon input voltage being applied. This addition gives the relay the property of time-delay actuation. Electronic Timing Relays are constructed to delay armature motion on coil energization, de-energization, or both. ETRs provide a wide range of selectable functions so that users can customize their specific machine operation. Relay Components and Operation What are the Best Features of Electronic Timing Relays? Electronic timing relays are used in a number of electronic applications, owing to the unending list of their features, which are as follows: • Multi-function timer, which allows the user to adjust between multiple timing functions. • High duty cycle applications. • DIN rail or panel mounting. • Resistant to mechanical shock and vibration.
    [Show full text]
  • Photovoltaic Couplers for MOSFET Drive for Relays
    Photocoupler Application Notes Basic Electrical Characteristics and Application Circuit Design of Photovoltaic Couplers for MOSFET Drive for Relays Outline: Photovoltaic-output photocouplers(photovoltaic couplers), which incorporate a photodiode array as an output device, are commonly used in combination with a discrete MOSFET(s) to form a semiconductor relay. This application note discusses the electrical characteristics and application circuits of photovoltaic-output photocouplers. ©2019 1 Rev. 1.0 2019-04-25 Toshiba Electronic Devices & Storage Corporation Photocoupler Application Notes Table of Contents 1. What is a photovoltaic-output photocoupler? ............................................................ 3 1.1 Structure of a photovoltaic-output photocoupler .................................................... 3 1.2 Principle of operation of a photovoltaic-output photocoupler .................................... 3 1.3 Basic usage of photovoltaic-output photocouplers .................................................. 4 1.4 Advantages of PV+MOSFET combinations ............................................................. 5 1.5 Types of photovoltaic-output photocouplers .......................................................... 7 2. Major electrical characteristics and behavior of photovoltaic-output photocouplers ........ 8 2.1 VOC-IF characteristics .......................................................................................... 9 2.2 VOC-Ta characteristic ........................................................................................
    [Show full text]
  • Experiment (1) Principles of Switching
    Experiment (1) Principles of Switching Introduction When you use microcontrollers, sometimes you need to control devices that requires more electrical current than a microcontroller can supply; for this, electrical relays and transistors are used. In this experiment, we will investigate two types of switching; electromechanical switching and solid state switching. Objectives This experiment aims to: 1- Understand the basic principles of switching devices. 2- Introduction to electromechanical switching as well as solid state switching. 3- Understand the advantages and disadvantages of each type. 4- Study the relative speed of different type of switches. Theory Electromechanically Relays Relays are electromechanical devices that use an electromagnet to operate a pair of movable contacts from an open position to a closed position. The relay is a switch that is controlled by a small electric current. It can be used to control motors, heaters or lamps circuits which themselves can draw a lot more electrical power. Figure 1 shows the circuit symbol for a relay. Figure 1: Circuit symbol for a relay In figure 2, the relay’s coil is energized by the low-voltage (12 VDC) source, while the single- pole, single-throw (SPST) contact interrupts the high-voltage (480 VAC) circuit. It is quite likely that the current required to energize the relay coil will be hundreds of times less than the current rating of the contact. Typical relay coil currents are well below 1 amp, while typical contact ratings for industrial relays are at least 10 amps. Mechatronics Systems Design Lab Figure 2: Relay drive an AC load One relay coil/armature assembly may be used to actuate more than one set of contacts.
    [Show full text]
  • IXYS Integrated Circuits Division Introduces High Current MOSFET Power Solid State Relay (SSR)
    PRESS RELEASE Contact: Catherine Austin Ph: 978 - 524 - 6823 Fax: 978 - 524 - 4900 IXYS Integrated Circuits Division Introduces High Current MOSFET Power Solid State Relay (SSR) The CPC1 7 0 5Y is a 60V, DC - Only Power Relay , I deal for Variety of High Performance Reliable Switching Applications Beverly, MA – October 1 2, 2017. IXYS Integrated Circuits Division (ICD), Inc., a wholly owned subsidia ry of IXYS Corporation (NASDAQ: IXYS), announced the imm edi ate availability of the CPC1705Y, a 60V, 3.25A , DC - Switching Power SSR. This is the industry’s highest load current rating for a single - pole normally closed ( 1 - Form B) solid state relay using an opti c ally coupled, single MOSFET output switch architecture in a p ower IC package . T he CPC1705Y SSR provides 2500Vrms of input to output isolation and has a very low 0.09 o hms maximum on - r esistance. The relay output is constructed with an efficient MOSFET switch that utilizes I CD’s patented O ptoMOS architecture. The input contro ls the optically cou pled output requiring only 5mA of input current to activate the isolated DC switch. The device is offered in IXYS ICD’s 4 - pin Power Single In - line Package (Power SIP) (10.2 height X 21 .1 length X 3.3 width in mm) which facilitates multiple channel switching in dense printed circuit board design s and has an operational temperature range from - 40 to +85 Celsius. Off state leakage current is 1 microampere maximum at 25 Celsius. The CPC17 05Y 1 - Form - B SSR is complementary to IXYS ICD’s popular CPC1706Y Normally Open ( 1 - Form - A ) SSR with similar specifications.
    [Show full text]
  • Hands on Relay School Transformer Protection Open Lecture Hands on Relay School Transformer Protection Open Lecture
    Hands On Relay School Transformer Protection Open Lecture Hands On Relay School Transformer Protection Open Lecture Class Outline • Transformer protection overview • Review transformer connections • Discuss challenges and methods of current differential Protection • Discuss other protective elements used in transformer protection Scott Cooper [email protected] (727)415-5843 Eastern Regional Manager 204 37th Avenue North #281 Manta Test Systems Saint Petersburg, FL 33704 Transformer Protection Overview Transformer Protection Zones Types of Protection Mechanical Protection • Analysis of Accumulated Gases – Looks for arcing by‐products • Sudden Pressure Relays – Orifice allows for normal thermal expansion/contraction. Arcing causing pressure waves in oil or gas space overwhelming the orifice and actuating the relay. • Thermal – Caused by overload, over excitation, harmonics and geo magnetically induced currents • Hot spot temperature • Top Oil • LTC Overheating Types of Protection Relay Protection • Internal Short Circuit – Phase: 87HS, 87T – Ground: 87HS, 87T, 87GD • System Short Circuit Back Up Protection – Phase and Ground Faults • Buses: 50, 50N, 51, 51N, 46 • Lines: 50, 50N, 51, 51N, 46 Types of Protection Relay Protection • Abnormal Operating Conditions – Open Circuits: 46 – Overexcitation: 24 – Undervoltage: 27 – Abnormal Frequency: 81U – Breaker Failure: 50BF, 50BF‐N Phase Differential Overview • What goes into a “unit” comes out of I + I + I = 0 a “unit” 1 2 3 • Kirchoff’s Law: The sum of the I I 1 UNIT 2 currents entering and
    [Show full text]
  • ON Semiconductor Is
    ON Semiconductor Is Now To learn more about onsemi™, please visit our website at www.onsemi.com onsemi and and other names, marks, and brands are registered and/or common law trademarks of Semiconductor Components Industries, LLC dba “onsemi” or its affiliates and/or subsidiaries in the United States and/or other countries. onsemi owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of onsemi product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent-Marking.pdf. onsemi reserves the right to make changes at any time to any products or information herein, without notice. The information herein is provided “as-is” and onsemi makes no warranty, representation or guarantee regarding the accuracy of the information, product features, availability, functionality, or suitability of its products for any particular purpose, nor does onsemi assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. Buyer is responsible for its products and applications using onsemi products, including compliance with all laws, regulations and safety requirements or standards, regardless of any support or applications information provided by onsemi. “Typical” parameters which may be provided in onsemi data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. onsemi does not convey any license under any of its intellectual property rights nor the rights of others.
    [Show full text]
  • Design Considerations for Solid State Relays Application Note 5452
    Design Considerations for Solid State Relays Application Note 5452 Introduction Solid State Relay and Electromechanical Relay For low voltage signaling applications or low power Comparison switching applications, optically isolated solid state relays A solid state relay offers significant advantages to the (SSRs) with MOSFET outputs provide significant advan- designer. Paramount amongst these advantages is the tages over traditional electromechanical relays (EMRs). almost infinite switching cycles an SSR can perform since In this application note, novel input LED drive current there are no mechanical parts or mechanisms to wear-out. circuits that ensure proper SSR turn-on and turn-off are The solid state reliability and billions of switching cycles discussed. Design techniques for paralleling SSRs for are the SSRs most significant features. Other advantages higher load current or for stacking SSRs for higher load include no contact bounce, the ability to handle relatively withstand voltages are also shown. Finally, example high inrush currents, and immunity to EMI and RFI. applications will show where the strengths of SSRs can be There are no mechanical parts inside SSRs and as a result particularly well used. they are essentially immune to shock, vibration and acceleration. Optically isolated solid state relays are classified as: Form A, single pole, single-throw, normally open; Form B, single Some disadvantages of the SSR include a small but finite pole, single throw, normally closed; and Form C, single off-state leakage current and relatively higher output on pole, double throw with one contact closed and the resistance compared to EMRs. In addition, it is difficult to other contact open.
    [Show full text]
  • Technical Explanation for General-Purpose Relays
    Technical Explanation for General-purpose Relays CSM_GeneralRelay_TG_E_10_2 Introduction Sensors What Is a Relay? Basically, a Relay is a device with contacts that opens and closes a switch as the result of an input signal (voltage or current) applied to a coil. Signal applied to Electromagnetism The output Switches Safety Components Relays Control Components Automation Systems Motion / Drives an input coil. operates a motion. contacts operate. Motion is transferred. Output Other Names • Electromagnetic relay Input • Auxiliary relay • Miniature relay •Power relay etc. Electromagnetic section Switch (coil) (contact structure) To get an idea of what relays are, think of a children's athletic carnival. The baton Little A holds on tightly to the baton and passes it to the big B. is the signal. This is a relay. Little A Big B Energy Conservation Support / Environment Measure Equipment Power Supplies / In Addition Others Common 1 Technical Explanation for General-purpose Relays Applications for Relays Sensors Relays are widely used in most machines and devices that use electricity. Refrigerators Home electrical appliances Washing machines, etc. Switches Safety Components Relays Control Components Automation Systems Motion / Drives Molding equipment Packing machinery Industrial machinery Industrial robots Programmable controllers, etc. Chemical plants Shale gas plants Plants Control panels at power stations and transformer substations Control panels for building management, etc. Relay Applications Scientific equipment Constant temperature tanks, etc. Automatic vending machines Vending machines and entertainment equipment Amusement machines, etc. Energy Conservation Support / Environment Measure Equipment Communications and Measurement equipment, etc. measurement equipment Power Supplies / In Addition OA devices Copy machines, etc. Others Common 2 Technical Explanation for General-purpose Relays Types of Relays Sensors There are mainly two types of relays: mechanical relays and solid state relays.
    [Show full text]
  • R842 Electronic Relay for Electric Baseboards
    R842 Electronic Relay For Electric Baseboards • Built-in transformer • Universal replacement part • Compatible with electronic T186 room sensor Description Viconics’ innovative R842 electronic relay has been designed for silent control of high voltage resistive heater loads (120V to 600 Vac) from a low voltage control circuit. Typical applications include control of electric baseboard and cabinet heaters in commercial buildings. Inductive motor loads can also be controlled (120 and 240 Vac models only). Using advanced microprocessor-based circuitry, the R842 is capable of handling greater than 500,000 cycles (typical). It has a built-in transformer and is compatible with most industry standard electromechanical or electronic thermostats with on/off outputs. A unique feature of product is that it can operate with a value priced Viconics’ T186 electronic PI (proportional and integral) room thermostat with setpoint capability, providing exceptional accuracy, comfort, and energy savings. Fig.1 - R842 relay for electric baseboards Features Benefits ⇒ Permits fully electronic PI control • Unique compatibility with Viconics’ own designer ⇒ Improved accuracy (+/-0.3ºC) and comfort electronic thermostat ⇒ Energy savings ⇒ Aesthetically pleasing thermostat • Reliable microprocessor-based design ⇒ Long life • Compatible with all standard 24 V thermostats ⇒ Adds flexibility ⇒ Not affected by ambient temperatures typically • Constant 10 second time delay found in older, thermal type baseboard relays ⇒ Less inventory to stock • Built-in transformer
    [Show full text]
  • Inductive Load Arc Suppression Application Note
    Application Note: Inductive Load Arc Suppression Figure 2. Introduction Bidirectional TVS Diode When a reed switch or reed sensor is used to control an Reed Switch/Sensor inductive device (relay coil, solenoid, transformer, small motor, etc.), the energy stored in the inductance in the device Load will subject the switch contacts to a high voltage when the reed switch opens. When the switch contacts open, the contact gap is initially small. Arcing across this contact gap RL can occur immediately after the switch opens. This can TVS Vs happen in resistive as well as inductive loads, but inductive loads generate a higher voltage and this causes increased L arcing. Increased arcing decreases switch life. Direct current (DC) inductive circuits typically use a diode to prevent the high voltage. The diode in the circuit is called a suppression diode, flyback diode, freewheeling diode, or catch diode. However, a diode cannot be used in an alternating current (AC) circuit. AC arc suppression requires the use of a RC suppression has the advantage of limiting the switch metal-oxide varistor (MOV), a bidirectional transient voltage contact voltage at the time of switch opening when the suppressor (TVS) diode, or an RC suppression network. An size of the contact gap is small. RC suppression can also RC suppression network is also called a snubber. The various be used to reduce arcing and improve life in resistive arc suppression methods have various advantages and loads. With RC suppression, a seriesconnected capacitor disadvantages. Using no suppression is also an option if life and resistor network is placed across (in parallel with) the is adequate without it.
    [Show full text]
  • Low-Cost AC Solid-State Relay with Mosfets Reference Design
    TI Designs Low-Cost AC Solid-State Relay With MOSFETs Description Features The low-cost AC solid-state relay (SSR) with • No Clicking Sound MOSFETs reference design is a single relay • Low-Cost BOM replacement that enables efficient power management for a low-power alternative to standard • MOSFET Based Design for Fast ON/OFF electromechanical relays in thermostat applications. Switching This SSR reference design is the base model of the • Self-Powered self-powered SSR providing a low-cost solution for • Zero Power From Thermostat Battery low-cost thermostats. • Inherent Snubber Circuit Reducing Voltage Spike Resources Created by Inductive Loads • Low Power and Quiescent Current Components TIDA-01064 Design Folder • Undervoltage Protection ATL431 Product Folder LP339 Product Folder Applications SN74AUP1G74 Product Folder • Thermostats CSD18541F5 Product Folder TIDA-00377 Tools Folder • HVAC Systems TIDA-00751 Tools Folder • Building Automation ASK Our E2E Experts Undervoltage lockout DC power supply LP339(A) 2 × ATL431 Control logic ON MOSFET switch 24 V SN74LVC1G74 AC OFF 2 × CSD18541F5 LP339(B,C,D) Load Copyright © 2016, Texas Instruments Incorporated An IMPORTANT NOTICE at the end of this TI reference design addresses authorized use, intellectual property matters and other important disclaimers and information. TIDUC87A–September 2016–Revised March 2017 Low-Cost AC Solid-State Relay With MOSFETs 1 Submit Documentation Feedback Copyright © 2016–2017, Texas Instruments Incorporated System Overview www.ti.com 1 System Overview 1.1 System Description A solid-state relay (SSR) is an electronic switching device that switches on or off when a small external voltage is applied across its control terminals. SSRs consist of an input logic to respond to an appropriate input (control signal), a solid-state electronic switching device to switch power to the load circuitry, and a coupling mechanism to enable the control signal to activate this switch without mechanical parts.
    [Show full text]