TEST REPORT Report No.: ATL202005221221R01
Total Page:16
File Type:pdf, Size:1020Kb
ROHS TEST REPORT Report No.: ATL202005221221R01 TEST REPORT Product: Air Purifier(Ozone Generator) Applicant: Safety Home Appliance Co., Limited Address: No. B401, Building 1, No. 27, Baijiaonan Road, Baijiao Industrial Park, Baijiao Town, Doumen District, Zhuhai City, Guangdong Province, China Manufacturer: Safety Home Appliance Co., Limited Address: No. B401, Building 1, No. 27, Baijiaonan Road, Baijiao Industrial Park, Baijiao Town, Doumen District, Zhuhai City, Guangdong Province, China Model No: ST-3.5G, ST-5G, ST-6G, ST-7G, ST-10G, ST-10GA, ST-12G, ST-15G, ST-20G, ST-600/HO1, ST-600/HO2, ST-600/HO3, ST-600/HO2UV, ST-600/HO3UV, ST-600/HO4UV, ST-600/HO4UV2, ST-UV36, ST-UV72, ST-301, ST-302, ST-303, ST-300/A, ST-IO3CUH, ST-150, ST-10GB, ST-5GA, ST-5GB Date of Sample Received: 2020-05-15 Testing Period: 2020-05-15 to 2020-05-22 Verification Requested :. With reference to RoHS Directive (EU) 2015/863 amending 2011/65/EU.. Verification Method :. Please refer to next page(s).. Verification Result :. Please refer to next page(s).. Verification Conclusion :. Based on the verification results of the submitted samples, the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) do not exceed the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Note :. The test results are related only to the tested items. The report shall not be reproduced except in full without the written approval of the testing laboratory.. Check by : Date : 2020-05-22 (Jane He) Approved by : Date : 2020-05-22 (July Yan) Shenzhen ATL Testing Technology Co., Ltd. Address: Floor.5, Genesis Zhongye Building, No.22, Puzai Road, Pingdi Street, Longgang District, Shenzhen, Guangdong, China Web:Http:// www.atllab.org Mail:[email protected] 1 OF 13 ROHS TEST REPORT Report No.: ATL202005221221R01 Test Method: Testing item Pretreatment method Measuring MDL instrument Lead(Pb) IEC 62321-5:2013 ICP-OES 2 mg/kg Cadmium(Cd) IEC 62321-5:2013 ICP-OES 2 mg/kg Mercury(Hg) IEC 62321-4:2013/AMD 1:2017 ICP-OES 2 mg/kg IEC 62321-7-1:2015 UV-Vis / Chromium(Cr VI) IEC 62321-7-2:2017 UV-Vis 10mg/kg PBBs IEC 62321-6:2015 GC-MS 30 mg/kg PBDEs IEC 62321-6:2015 GC-MS 30 mg/kg DIBP IEC 62321-8:2017 GC-MS 30 mg/kg DEHP IEC 62321-8:2017 GC-MS 30 mg/kg DBP IEC 62321-8:2017 GC-MS 30 mg/kg BBP IEC 62321-8:2017 GC-MS 30 mg/kg Shenzhen ATL Testing Technology Co., Ltd. Address: Floor.5, Genesis Zhongye Building, No.22, Puzai Road, Pingdi Street, Longgang District, Shenzhen, Guangdong, China Web:Http:// www.atllab.org Mail:[email protected] 2 OF 13 ROHS TEST REPORT Report No.: ATL202005221221R01 Test Flow: 1. Lead(Pb), Cadmium(Cd) In the microwave Weighing sample in Add the digestion digestion furnace Filter taper bottle solution digestion sample With ashing/soda Residue boiling/acid cooking method processing Tested by DI water constant ICP-OES volume solutio 2. Mercury (Hg) In the microwave Weighing sample in Add the digestion digestion furnace Filter microwave solution digestion sample With ashing/soda boiling/acid cooking Residue method processing Tested by DI water constant ICP-OES volume solutio 3. Chromium(Cr VI) 90-95℃heating 3 Weighing sample Add the digestion Cooling, Filter in taper bottle solution hours DI water Tested by constant Adjustment Add test Adjustment UV-Vis volume solution PH solution solution PH Shenzhen ATL Testing Technology Co., Ltd. Address: Floor.5, Genesis Zhongye Building, No.22, Puzai Road, Pingdi Street, Longgang District, Shenzhen, Guangdong, China Web:Http:// www.atllab.org Mail:[email protected] 3 OF 13 ROHS TEST REPORT Report No.: ATL202005221221R01 4. PBBs/ PBDEs Weighing sample Using organic Concentrated extract in the casing solvent extraction Tested by Using organic solvent Transfer extraction solution to GC-MS constant volume the volumetric flask inside 5. DEHP/ BBP/ DBP/ DIBP Sample cutting Sample Solvent /preparation measurement extraction Concentration/ Tested by GC-MS Filtration dilution Shenzhen ATL Testing Technology Co., Ltd. Address: Floor.5, Genesis Zhongye Building, No.22, Puzai Road, Pingdi Street, Longgang District, Shenzhen, Guangdong, China Web:Http:// www.atllab.org Mail:[email protected] 4 OF 13 ROHS TEST REPORT Report No.: ATL202005221221R01 Test Results: Testing Item Unit ROHS Result Limit 1 2 3 4 5 6 Lead(Pb) mg/kg 1000 N.D.N.D. N.D. N.D. N.D. N.D. Cadmium(Cd) mg/kg 100 N.D. N.D. N.D. N.D. N.D. N.D. Mercury(Hg) mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Chromium(Cr VI) mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Sum of PBBs mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Monobromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Dibromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tribromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tetrabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Pentabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Hexabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Heptabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Octabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Nonabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Decabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Sum of PBDEs mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Monobromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Dibromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tribromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tetrabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Pentabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Hexabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Heptabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Octabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Nonabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Decabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Diisobutyl phthalate(DIBP) mg/kg 1000 N.D.N.D. N.D. N.D. N.D. N.D. Bis-(2-ethylhecyl) Phthalate mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. (DEHP) Benzylbutyl Phthalate (BBP) mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Dibutyl Phthalate (DBP) mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Shenzhen ATL Testing Technology Co., Ltd. Address: Floor.5, Genesis Zhongye Building, No.22, Puzai Road, Pingdi Street, Longgang District, Shenzhen, Guangdong, China Web:Http:// www.atllab.org Mail:[email protected] 5 OF 13 ROHS TEST REPORT Report No.: ATL202005221221R01 Testing Item Unit ROHS Result Limit 7 8 9 10 11 12 Lead(Pb) mg/kg 1000 N.D.N.D. N.D. N.D. N.D. N.D. Cadmium(Cd) mg/kg 100 N.D. N.D. N.D. N.D. N.D. N.D. Mercury(Hg) mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Chromium(Cr VI) mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Sum of PBBs mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Monobromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Dibromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tribromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tetrabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Pentabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Hexabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Heptabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Octabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Nonabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Decabromobiphenyl mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Sum of PBDEs mg/kg 1000 N.D. N.D. N.D. N.D. N.D. N.D. Monobromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Dibromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tribromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Tetrabromodiphenyl ether mg/kg / N.D. N.D. N.D. N.D. N.D. N.D. Pentabromodiphenyl ether mg/kg / N.D.