Oscilloscope & Multimeter

Total Page:16

File Type:pdf, Size:1020Kb

Oscilloscope & Multimeter INSTRUCTION OVERVIEW FOR Oscilloscope & Multimeter Stock No.64573 Part No.O20M/3C IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder of the product. Read all these instructions before assembling, operating or maintaining this product. This manual has been compiled by Draper Tools describing the purpose for which the product has been designed, and contains all the necessary information to ensure its correct and safe use. By following all the general safety instructions contained in this manual, it will ensure both product and operator safety, together with longer life of the product itself. AlI photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product. Whilst every effort has been made to ensure the accuracy of information contained in this manual, the Draper Tools policy of continuous improvement determines the right to make modifications without prior warning. 1. TITLE PAGE 1.1 INTRODUCTION: USER MANUAL FOR: OSCILLOSCOPE & MULTIMETER Stock no. 64573 Part no. O20M/3C 1.2 REVISIONS: Date first published March 2015 As our user manuals are continually updated, users should make sure that they use the very latest version. Downloads are available from: http://www.drapertools.com/b2c/b2cmanuals.pgm DRAPER TOOLS LIMITED WEBSITE: drapertools.com HURSLEY ROAD PRODUCT HELPLINE: +44 (0) 23 8049 4344 CHANDLER’S FORD GENERAL FAX: +44 (0) 23 8026 0784 EASTLEIGH HAMPSHIRE SO53 1YF UK 1.3 UNDERSTANDING THIS MANUALS SAFETY CONTENT: WARNING! Information that draws attention to the risk of injury or death. CAUTION! Information that draws attention to the risk of damage to the product or surroundings. 1.4 COPYRIGHT © NOTICE: Copyright © Draper Tools Limited. Permission is granted to reproduce this publication for personal & educational use only. Commercial copying, redistribution, hiring or lending is prohibited. No part of this publication may be stored in a retrieval system or transmitted in any other form or means without written permission from Draper Tools Limited. In all cases this copyright notice must remain intact. Brief introduction ..................................................................................................... 3 Package Checklist .................................................................................................... 5 Chapter I、Recognizing this product ....................................................................... 6 1、 Product Description .................................................................................. 6 1.1 Front Panel ...................................................................................... 6 1.2 Measurement port ............................................................................ 7 2、Panel keyboard and display interface ......................................................... 8 2.1 Panel function keys ......................................................................... 8 2.2 Display Interface ............................................................................. 9 3、The main measurement function and menu structure .............................. 10 3.1 The main measurement function ................................................... 10 3.2 Menu structure ............................................................................... 10 Chapter II、Use instrument ................................................................................... 19 1、Oscilloscope ............................................................................................. 19 1.1 Test connection ............................................................................. 19 1.2 Oscilloscope measurement applications ........................................ 20 2、DMM ........................................................................................................ 24 2.1 Test the connection ........................................................................ 24 2.2 Multimeter ..................................................................................... 24 Chapter III、The Instrument in the automotive fault diagnosis ............................ 26 1、 Safety Precautions .................................................................................. 26 2、 Introduction ............................................................................................ 28 2.1 Primary Signal Types Found In Modern Vehicles ........................ 28 2.2 Critical Characteristics Of Automotive Electronic Signals ........... 30 2.3 The Golden Rule Of Electronic System Diagnosis ....................... 30 2.4 Signal Probing With An Oscilloscope .......................................... 31 3、 Automotive Testing ................................................................................ 32 3.1 Into the automotive component testing menu ............................... 32 3.2 Sensor Test .................................................................................... 33 3.3 Ignition System Test ...................................................................... 91 1 3.4 Auxiliary Test .............................................................................. 106 3.5 Diesel menu ................................................................................. 120 Chapter IV、 Interface and Software .................................................................... 124 Chapter V、 Maintenance and repair .................................................................. 126 Chapter VI、Disposal .......................................................................................... 128 Chapter VI、Technical Specifications ............................................................... 129 2 Brief introduction The Automotive Oscilloscope & Multimeter is a 20MHz digital storage oscilloscope, 6000 words True RMS Digital Multimeter, automotive electronics measurement functions integrated multifunctional handheld instrument, ideal for field use. The main function • 3-channel, 20MHz digital storage oscilloscope • True 6000 words RMS digital multimeter • Automotive electronic measurement: sensors, actuators, ignition systems, electrical component testing Features • 100MSa / s real-time sampling rate, 20MHz real-time bandwidth • Automotive electrical measurements, 51 kinds of automotive standards Reference Waveform • Automatic tracking measurement: automatic tracking based on external input signal to adjust the vertical amplitude \ horizontal time base and trigger stalls, without human intervention • Large dynamic measurement range: no extended probe leads directly measure range from 10mV/div to 500V/div • Screen can display 4 measurement parameters:the user can choose RMS, peak, average, frequency, period, in 22 kinds of parameters as needed, etc. • Two kinds of cursor measurement mode selection • 320 * 240 dot TFT LCD, • Built-in battery, AC and DC • Recorder --- continuous track record up to 12 hours of event • Standard USB interface, through the PC software can easily communicate with a computer for data analysis and test results archive 3 5. HEALTH & SAFETY INFORMATION 5.1 GENERAL SAFETY INSTRUCTIONS For your own safety and the safety of others, and to prevent damage to the equipment and vehicles, read this manual thoroughly before operating your scanner. The safety messages presented below and throughout this user’s manual are reminders to the operator to exercise extreme care when using this device. Always refer to and follow safety messages and test procedures provided by vehicle or equipment manufacturer. Read, understand and follow all safety messages and instructions in this manual. Safety Message Conventions Used We provide safety messages to help prevent personal injury and equipment damage. Below are signal words we used to indicate the hazard level in a condition. ! DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury to the operator or to bystanders. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to the operator or to bystanders. ! CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor injury to the operator or to bystanders. 5.2 SPECIFIC SAFETY INSTRUCTIONS Always use your oscilloscope as described in the user’s manual, and follow all safety messages. ! WARNING Do not route the test cables in a manner that would interfere with driving controls. Do not exceed voltage limits between inputs specified in this user’s manual. Always wear approved goggles to protect your eyes from propelled objects as well as hot or caustic liquids. Fuel, oil vapours, hot steam, hot toxic exhaust gases, acid, refrigerant and other debris produced by a malfunctioning engine can cause serious injury or death. Do not use the scanner in areas where explosive vapour may collect, such as in below-ground pits, confined areas, or areas that are less than 18 inches (45 cm) above the floor. Do not smoke, strike a match, or cause a spark near the vehicle while testing and keep all sparks, heated items and open flames away from the battery and fuel / fuel vapours as they are highly flammable. Keep a dry chemical fire extinguisher suitable for gasoline, chemical and electrical
Recommended publications
  • Digital Power Analyzer Model 4301
    Model 4301 Modular Power Analyzer An All-Purpose Digital Measurement Instrument for Power Conversion Device Testing Model 4301 Modular Power Analyzer 0.1% reading and 0.1% range accuracy Up to 16 Power Analyzer modules in a single chassis 25 standard AC and DC, static and dynamic measurements Dual DSPs with 1MHz sampling rate 6 voltage and current ranges plus auto-ranging for increased accuracy Peak-Peak noise measurements, 10Hz - 20MHz Two Digital Logic Inputs per module Chassis communications through a PC/LAN with LabVIEW and IVI- compliant drivers Applications The Model 4301 Power Analyzer is primarily designed for use in automated test environments configured for simultaneous testing of multiple power conversion UUTs. The Analyzer’s advantage in this application are speed, size and measurement performance. Speed is achieved through having Model 4301 a single instrument capable of making a wide range of measurements dedicated to each test channel. Test system size is minimized through the modular single-card design, 16 of which can be fitted into a multi-instrument chassis. Measurement performance is achieved by deriving an extensive number of high accuracy measurements from a digitized waveform. This last capability is particularly useful where input as well as output measurements are necessary to precisely calculate UUT efficiency. 3 Instruments in 1 Through Waveform Digitization The 4301 Analyzer can be thought of as functionality equivalent to three instruments: a power meter, a multimeter and an oscilloscope. This capability is achieved through the Analyzer’s state-of-the-art, dual A/D converters with a 1MHz sampling rate that provides the data to make practically any power- conversion-related static or dynamic measurement provided by the three types of instruments above.
    [Show full text]
  • Electrical Multimeter MMW02
    Motors | Automation | Energy | Transmission & Distribution | Coatings Electrical Multimeter MMW02 Installation & Operation Manual Installation & Operation Manual Serie: MMW02 Language: English Summary SUMMARY 1 INTRODUCTION 10 1.1 CALIBRATION EXPIRY TERM ............................................................................................................10 1.2 CONFORMITY DECLARATION .............................................................................................................. 10 1.2.1 Reference Standards ................................................................................................................10 1.3 SAFETY INFORMATION .....................................................................................................................10 1.3.1 Dangers .....................................................................................................................................11 1.3.2 Attention ....................................................................................................................................11 1.4 RECEIVING THE PRODUCT ...............................................................................................................11 1.5 TECHNICAL SUPPORT AND ASSISTANCE ......................................................................................11 2 OVERVIEW 13 2.1 MEASURE OF BASIC QUANTITIES .................................................................................................13 2.2 THD CALCULATION ...........................................................................................................................13
    [Show full text]
  • An Oscilloscope Correction Method for Vector-Corrected RF Measurements
    This article has been accepted for inclusion in a future issue of this journal. Content is final as presented, with the exception of pagination. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 1 An Oscilloscope Correction Method for Vector-Corrected RF Measurements Sebastian Gustafsson, Student Member, IEEE, Mattias Thorsell, Member, IEEE, Jörgen Stenarson, Member, IEEE, and Christian Fager, Member, IEEE Abstract— The transfer characteristics of the RF front-end circuit components. As these errors must be compensated for circuitry of a real-time oscilloscope (RTO) are not only frequency to achieve accurate signal sampling [4], several correction dependent and nonlinear with signal amplitude but also depen- techniques have been introduced [5], [6]. Other correction dent on the voltage range setting of the oscilloscope. A correction table in the frequency domain is proposed to account for the techniques have also been introduced [7]–[12], but they are additional gain and delay introduced when switching between only valid for sampling oscilloscopes. Previous research different voltage ranges. The table was extracted from the has focused on correction techniques for a certain set of measured data in which a continuous-wave signal source was instrument settings, e.g., a particular voltage range. Hence, connected to the oscilloscope ports, whereas the input power, the changing the settings would make the correction invalid. frequency, and voltage ranges were varied. The importance of the corrections is demonstrated by its use in an RTO-based two-port However, changing the range is desirable in some applications, vector-corrected measurement system. Measurements from the to fully utilize the voltage range of the ADC.
    [Show full text]
  • Keysight 53147A/148A/149A Microwave Frequency Counter/Power Meter/DVM
    Keysight 53147A/148A/149A Microwave Frequency Counter/Power Meter/DVM Assembly Level Service Guide Notices U.S. Government Rights Warranty The Software is “commercial computer THE MATERIAL CONTAINED IN THIS Copyright Notice software,” as defined by Federal Acqui- DOCUMENT IS PROVIDED “AS IS,” sition Regulation (“FAR”) 2.101. Pursu- AND IS SUBJECT TO BEING © Keysight Technologies 2001 - 2017 ant to FAR 12.212 and 27.405-3 and CHANGED, WITHOUT NOTICE, IN No part of this manual may be repro- Department of Defense FAR Supple- FUTURE EDITIONS. FURTHER, TO THE duced in any form or by any means ment (“DFARS”) 227.7202, the U.S. MAXIMUM EXTENT PERMITTED BY (including electronic storage and government acquires commercial com- APPLICABLE LAW, KEYSIGHT DIS- retrieval or translation into a foreign puter software under the same terms CLAIMS ALL WARRANTIES, EITHER language) without prior agreement and by which the software is customarily EXPRESS OR IMPLIED, WITH REGARD written consent from Keysight Technol- provided to the public. Accordingly, TO THIS MANUAL AND ANY INFORMA- ogies as governed by United States and Keysight provides the Software to U.S. TION CONTAINED HEREIN, INCLUD- international copyright laws. government customers under its stan- ING BUT NOT LIMITED TO THE dard commercial license, which is IMPLIED WARRANTIES OF MER- Manual Part Number embodied in its End User License CHANTABILITY AND FITNESS FOR A 53147-90010 Agreement (EULA), a copy of which can PARTICULAR PURPOSE. KEYSIGHT be found at http://www.keysight.com/ SHALL NOT BE LIABLE FOR ERRORS Edition find/sweula. The license set forth in the OR FOR INCIDENTAL OR CONSE- Edition 3, November 1, 2017 EULA represents the exclusive authority QUENTIAL DAMAGES IN CONNECTION by which the U.S.
    [Show full text]
  • Power Meter Ml2430a Series Maintenance Manual
    Maintenance Manual POWER METER ML2430A SERIES MAINTENANCE MANUAL Anritsu Company Part Number: 10585-00003 490 Jarvis Drive Revision: J Morgan Hill, CA 95037-2809 Published: February 2021 USA Copyright 2021 Anritsu Company Notes On Export Management This product and its manuals may require an Export License or approval by the government of the product country of origin for re-export from your country. Before you export this product or any of its manuals, please contact Anritsu Company to confirm whether or not these items are export-controlled.When disposing of export-controlled items, the products and manuals need to be broken or shredded to such a degree that they cannot be unlawfully used for military purposes. NOTICE Anritsu Company has prepared this manual for use by Anritsu Company personnel and customers as a guide for the proper installation, operation and maintenance of Anritsu Company equipment and computer programs. The drawings, specifications, and information contained herein are the property of Anritsu Company, and any unauthorized use or disclosure of these drawings, specifications, and information is prohibited; they shall not be reproduced, copied, or used in whole or in part as the basis for manufacture or sale of the equipment or software programs without the prior written consent of Anritsu Company. UPDATES Updates, if any, can be downloaded from the Documents area of the Anritsu Website at: http://www.anritsu.com For the latest service and sales contact information in your area, please visit: https://www.anritsu.com/Contact-US/ Table of Contents Chapter 1—General Information 1-1 Scope Of This Manual .
    [Show full text]
  • Future of Vector Network Analysis Dylan Williams and Nate Orloff Integrated Circuits Drive Wireless Communications
    Future of Vector Network Analysis Dylan Williams and Nate Orloff Integrated Circuits Drive Wireless Communications Application Frequency (GHz) 10 30 100 300 1000 100 10 Transit Frequency (GHz) Frequency Transit 1990 1995 2000 2005 2010 2015 2020 Year We Cannot Take the Integrated Circuit for Granted at mmWaves 2 Next 15 Years of Wireless Manufacturing by Country The United States still dominates mmWave manufacturing Enables $12.3T in Total Economic Growth (2020-2035) Communication Providers Want Speed of Fiber on Your Phone Millimeter-Waves are the Next Wireless Frontier Measurements and Calibrations Matter at mmWaves Before Calibration 64 QAM at 44 GHz After Calibration mmWave Measurement Challenge of our Era Not a Single RF Connector! On-Wafer IC and System-Level Test OTA System-Level Test Transistor models IC Test System-Level Test End-to-End Verification On-Wafer Connectorized Free-Space Goals for Vector Network Analysis in CTL Project Calibration Reference Planes On-Wafer and to OTA Test On-Wafer Measurements • Innovations in Calibration • Support Device Models to System-Level Test • State-Of-The-Art Instruments for US mmWave NR Manufacturers Vector Network Analysis • Platform for Traceable System-Level Tests Across CTL • Close the Connector-Less Gap mmWave Design Extremely Complex Accurate measurements are a must 80 80 GHz GHz 160 ~ GHz 240 GHz • Highly nonlinear operating states required for efficiency • Characterize, capture, control and reuse harmonics • Must maintain linearity On-Wafer Measurement the Only Way to Test ICs Yesterday
    [Show full text]
  • P50xxa Streamline Series Vector Network Analyzer 2/4-Port up to 53 Ghz
    P50xxA Streamline Series Vector Network Analyzer 2/4-port Up to 53 GHz. 2/4/6-port Up to 20 GHz Compact Form. Zero Compromise. P5000A/P5020A 9 kHz to 4.5 GHz P5001A/P5021A 9 kHz to 6.5 GHz P5002A/P5022A 9 kHz to 9 GHz P5003A/P5023A 9 kHz to 14 GHz P5004A/P5024A 9 kHz to 20 GHz P5005A/P5025A 100 kHz to 26.5 GHz P5006A/P5026A 100 kHz to 32 GHz P5007A/P5027A 100 kHz to 44 GHz P5008A/P5028A 100 kHz to 53 GHz Find us at www.keysight.com Page 1 Keysight P500xA and P502xA Streamline Series VNA The freedom of portable network analysis doesn’t have to mean a compromise in performance. The P50xxA Series brings high-end performance and flexibility to the portable Keysight Streamline Series. Gain confidence in your measurements with best-in-class performance offering fast, reliable, and repeatable results. Explore the complete characterization of your devices with a rich portfolio of software applications that transform the compact network analyzer into a complete RF measurement solution. The P50xxA Series, a member of Keysight’s Streamline Series offers the performance required for testing passive components, amplifiers, mixers or frequency converters. The vector network analyzer (VNA) provides best-in-class key specifications such as dynamic range, measurement speed, trace noise and temperature stability. Choose from 2- or 4-port models up to 53 GHz, or 2-, 4- or 6-port models up to 20 GHz. The VNA is packaged in a compact chassis and controlled by an external computer with powerful data processing capabilities and functionalities.
    [Show full text]
  • 10 Factors in Choosing a Basic Oscilloscope 10 Factors in Choosing a Basic Oscilloscope Contents Intro 1 2 3 4 5 6 7 8 9 10 11 Contact 2
    10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE 10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE CONTENTS INTRO 1 2 3 4 5 6 7 8 9 10 11 CONTACT 2 10 Factors in Choosing a Basic Oscilloscope There are several ways to navigate this interactive PDF document: Click on the table of contents (page 3) Basic oscilloscopes are used as windows into signals for troubleshooting Use the navigation at the top of each page to jump circuits or checking signal quality. They generally come with bandwidths to sections or use the page forward/back arrows from around 50 MHz to 200 MHz and are found in almost every design lab, Use the arrow keys on your keyboard education lab, service center and manufacturing cell. Use the scroll wheel on your mouse Whether you buy a new scope every month or every five years, this guide will Left click to move to the next page, right click to move to the previous page (in full-screen mode only) give you a quick overview of the key factors that determine the suitability of a Click on the icon ß to enlarge the image. basic oscilloscope to the job at hand. The digital storage oscilloscope Oscilloscopes are the basic tool for anyone designing, manufacturing or repairing electronic equipment. A digital storage oscilloscope (DSO, on which this guide concentrates) acquires and stores waveforms. The waveforms show a signal’s voltage and frequency, whether the signal is distorted, timing between signals, how much of a signal is noise, and much, much more. 10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE CONTENTS INTRO 1 2 3 4 5 6 7 8 9 10 11
    [Show full text]
  • Model 2000 Multimeter User’S Manual 2000-900-01 Rev
    www.keithley.com Model 2000 Multimeter User’s Manual 2000-900-01 Rev. H / August 2003 A GREATER MEASURE OF CONFIDENCE WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of one (1) year from date of shipment. Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, software, rechargeable batteries, diskettes, and documentation. During the warranty period, Keithley Instruments will, at its option, either repair or replace any product that proves to be defective. To exercise this warranty, write or call your local Keithley Instruments representative, or contact Keithley Instruments headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service facility. Repairs will be made and the product returned, transportation prepaid. Repaired or replaced products are warranted for the balance of the original warranty period, or at least 90 days. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from product modification without Keithley Instruments’ express written consent, or misuse of any product or part. This warranty also does not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THE REMEDIES PROVIDED HEREIN ARE THE BUYER’S SOLE AND EXCLUSIVE REMEDIES. NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS INSTRUMENTS AND SOFTWARE, EVEN IF KEITHLEY INSTRUMENTS, INC.
    [Show full text]
  • Test & Measurement
    Test & Measurement Crafted for optimum durability, reliability and functionality, our line of test and measurement equipment is engineered with the user in mind. Designed for, and by electricians, our electrical testers provide the latest in innovative, time-saving features that professionals require. Electrical Test & Measurement CL200 AUTO AC A Tough Digital Clamp Meters SELECT: True RMSInstructions MeasurementPackaging Technology Includes: Features CL600 CL700 CL800 • Carrying case • Test leads with CAT III/CAT IV safety Drop Protection 6.6 ft. (2 m) 6.6 ft. (2 m) 6.6 ft. (2 m) caps Ingress Protection IP40 IP40 IP40 • Thermocouple with adapter (temperature-measuring models only) CAT IV 600V CAT IV 600V CAT IV 600V Safety CAT III 1000V CAT III 1000V CAT III 1000V • Batteries AC Voltage (Volts) 1000V 1000V 1000V DC Voltage (Volts) 1000V 1000V 1000V AC Current (Amps) 600A 600A 600A DC Current (Amps) – – 600A • CAT IV 600V, CAT III 1000V, Class 2, Double insulaton safety rating Ohms (Resistance) 60MΩ 60MΩ 60MΩ • Built to withstand a 6.6 ft. (2 m) drop • Meets requirements for use in basic and controlled electromagnetic AC Millivolts – – – environments like residential, office and light-industrial locations DC Millivolts • The CL600 is an auto-ranging TRMS digital clamp meter that True RMS measures AC current via the clamp, and measures AC/DC voltage, resistance, continuity, and tests diodes via test leads Audible Continuity • The CL700 is an auto-ranging TRMS digital clamp meter that measures AC current via the clamp, and measures AC/DC voltage, Backlight resistance, continuity, frequency, capacitance, and tests diodes -14° – 1000°F -14° – 1000°F via test leads, and temperature via a thermocouple probe.
    [Show full text]
  • Voltage and Power Measurements Fundamentals, Definitions, Products 60 Years of Competence in Voltage and Power Measurements
    Voltage and Power Measurements Fundamentals, Definitions, Products 60 Years of Competence in Voltage and Power Measurements RF measurements go hand in hand with the name of Rohde & Schwarz. This company was one of the founders of this discipline in the thirties and has ever since been strongly influencing it. Voltmeters and power meters have been an integral part of the company‘s product line right from the very early days and are setting stand- ards worldwide to this day. Rohde & Schwarz produces voltmeters and power meters for all relevant fre- quency bands and power classes cov- ering a wide range of applications. This brochure presents the current line of products and explains associated fundamentals and definitions. WF 40802-2 Contents RF Voltage and Power Measurements using Rohde & Schwarz Instruments 3 RF Millivoltmeters 6 Terminating Power Meters 7 Power Sensors for URV/NRV Family 8 Voltage Sensors for URV/NRV Family 9 Directional Power Meters 10 RMS/Peak Voltmeters 11 Application: PEP Measurement 12 Peak Power Sensors for Digital Mobile Radio 13 Fundamentals of RF Power Measurement 14 Definitions of Voltage and Power Measurements 34 References 38 2 Voltage and Power Measurements RF Voltage and Power Measurements The main quality characteristics of a parison with another instrument is The frequency range extends from DC voltmeter or power meter are high hampered by the effect of mismatch. to 40 GHz. Several sensors with differ- measurement accuracy and short Rohde & Schwarz resorts to a series of ent frequency and power ratings are measurement time. Both can be measures to ensure that the user can required to cover the entire measure- achieved through utmost care in the fully rely on the voltmeters and power ment range.
    [Show full text]
  • Lab 1 – Measurements of Frequency
    Physics of Music PHY103 Lab Manual Lab 1 – Measurements of Frequency EQUIPMENT and PREPARATION Part A: • Oscilloscopes (get 5 from teaching lab) • BK Precision function generators (get 5 from Thang or teaching lab) • Counter/timers (PASCO, 4 + 1 other) • Connectors and cables (BNC to BNC’s, banana plug pairs) connecting function/signal generators to oscilloscopes and speaker. • BNC to 2 leads • Adaptors: mike to BNC so that output of preamps can be looked at on oscilloscope. • BNC to banana adapters • BNC T- adapters • Oscilloscope probes • Pasco open speakers • Microphones, preamps, mic stands • Strobes (3) optional Warning: do not place speakers near oscilloscope screens as they can damage the CRT (cathode ray tube) screens. Note: The professor will attempt to have the equipment out and available for the labs. However the TAs/TIs should check that the equipment is ready to use, that every lab setup has all the necessary equipment. The TA/TIs should also be familiar with the lab and know how to troubleshoot the equipment. INTRODUCTION In this lab, we will be measuring the frequency of a signal using three different methods. The first method involves the use of the function generator. A function generator is an instrument that can produce sine, square, and triangular waves at a given frequency. The second method makes use of the oscilloscope. An oscilloscope is an instrument principally used to display signals as a function of time. The final method for measuring the frequency uses the counter/timer. A counter/timer is an instrument that can give a very accurate measurement of the frequency of a signal by counting each time a voltage crosses a particular value.
    [Show full text]