Myocardial Blood Flow Measurement by PET: Technical Aspects and Clinical Applications

Total Page:16

File Type:pdf, Size:1020Kb

Myocardial Blood Flow Measurement by PET: Technical Aspects and Clinical Applications Myocardial Blood Flow Measurement by PET: Technical Aspects and Clinical Applications Philipp A. Kaufmann, MD1; and Paolo G. Camici, MD2 1Nuclear Cardiology Section, Cardiovascular Center, University Hospital, Zurich, Switzerland; and 2Faculty of Medicine, Medical Research Council Clinical Sciences Centre, Imperial College, London, United Kingdom the symbol F/W is also used, have units of volume per time The availability of plastic microspheres labeled with dif- per unit weight of myocardium (i.e., mL/min/g). ferent ␥-emitting isotopes has allowed the quantification of To achieve the accurate quantification of tracer uptake, blood flow in different organs, including the heart (1). In the which is a characteristic of PET, correction for photon past 3 decades this has made it possible to study the changes attenuation is crucial. At present, a rotating 68Ge (half-life ϭ in myocardial blood flow (MBF) under different physio- 287 d) source is commonly used for photon attenuation logic and pathophysiologic conditions in experimental ani- correction in oncology but also in cardiac viability and mals. perfusion scanning. 68Ge sources have only a low photon In a similar fashion, the development of PET has allowed flux, which necessitates long acquisition times of up to 20 the noninvasive quantification of regional MBF in healthy min (6,7), although with current methods transmission times humans and patients with different cardiovascular diseases. much shorter than 20 min can be used. This results in This article summarizes how PET measurement of MBF has increased chance of motion artifacts and poor anatomic contributed to advance our understanding of cardiac phys- image quality as well as patient discomfort and economic iology and pathophysiology. loss because of lower patient throughput (8). Introduction of combined PET/CT systems, where the CT scan can be used for attenuation correction, is expected to allow improve- METHODOLOGIC AND TECHNICAL CONSIDERATIONS ment of these limitations since a high-end CT scanner is Several techniques, including Doppler catheterization able to acquire images with far higher spatial resolution in and coronary sinus thermodilution, are available for mea- a much shorter time (Ͻ4 s) compared with a conventional suring coronary blood flow (CBF) in humans. These tech- 68Ge transmission scan (68Ge attenuation correction). The niques, which are fundamentally variations of indicator feasibility of adequate photon attenuation correction with dilution methods, are invasive and affected by serious lim- the CT scan of a hybrid PET/CT scanner has been demon- itations (2). Although CBF, for which the symbol F is often strated for static PET scans using 18F-FDG (9,10) and, more used, has units of volume per time (i.e., mL/min), Doppler recently, also for dynamic scanning with 13N-labeled am- 13 measurements usually allow assessment of flow velocity monia ( NH3)(11). (cm/s) and only few techniques provide volumetric flow (3,4). Measurement of inert tracer clearance, which can be TRACERS AND CAMERAS invasive (based on arteriovenous sampling) or semiinvasive Various tracers have been used for measuring MBF by (e.g., based on external detection of radionuclide washout, PET, including 15O-labeled water (H 15O) (12–17), 13NH after intracoronary injection 133Xe) provides estimates of 2 3 (18–23), the cationic potassium analog 82Rb (24,25), 62Cu- regional perfusion, although the mass of tissue subtended by pyruvaldehyde bis(N4-methylthio-semicarbazone (62Cu- the artery under study is unknown (2). SPECT allows the PTSM) (26–30) and 11C as well as 68Ga-labeled albumin noninvasive assessment of directional changes in regional microspheres (31,32), 94mTc- teboroxime (33), and 38K(34). tissue perfusion, but its physical limitations do not permit 13 82 Early PET studies used NH3 (18) and Rb (35) for qual- quantification of MBF (5). PET has been shown to allow 13 itative assessments of regional MBF. Currently, NH3, noninvasive and accurate quantification of regional MBF if 15 82 H2 O, and Rb are the most widely used PET perfusion suitable tracers are used and appropriate mathematic models 13 82 tracers. NH3 and Rb are given intravenously as boluses. are applied. These PET measurements of MBF, for which 15 In the case of H2 O, the tracer can be administered as an intravenous bolus injection (6,12,15,36), an intravenous 15 Received Apr. 15, 2004; revision accepted Sep. 13, 2004. slow infusion (6,37), or by inhalation of O-labeled carbon 15 15 For correspondence or reprints contact: Paolo G. Camici, MD, Medical dioxide (C O2), which is then converted to H2 Obycar- Research Council Clinical Sciences Centre, Imperial College, Hammersmith 82 Hospital, Du Cane Rd., London W12 0NN, United Kingdom. bonic anhydrase in the lungs (14). Generator-produced Rb E-mail: [email protected] is a very appealing MBF tracer because it does not require MYOCARDIAL PERFUSION QUANTIFIED BY PET • Kaufmann and Camici 75 a cyclotron on site and has a very short half-life (78 s). estimates obtained with the 2 tracers in healthy human Although several models have been proposed for quantifi- subjects. However, in a highly heterogeneous tissue (e.g., cation of regional MBF using 82Rb (25,38–40), they are jeopardized myocardium in patients with previous infarc- 15 limited by the heavy dependence of the myocardial extrac- tion), the diffusion/extraction and final uptake of H2 O and 13 tion of this tracer on the prevailing flow rate and myocardial NH3 are determined by the flow rates in each tissue metabolic state. Therefore, quantification of regional MBF compartment—that is, higher in viable tissue and lower in 82 13 with Rb may be inaccurate, particularly during hyperemia scar tissue. NH3 uptake (on which the model for the or in metabolically impaired myocardium. In addition, the computation of MBF is based) in a given region of interest high positron energy (3.15 MeV) of this radionuclide results will reflect the average uptake and, hence, average flow in in relatively poor image quality and in a reduced spatial this mixture of viable and fibrotic tissue. On the other hand, 15 resolution due to its relatively long positron track. since the uptake of H2 O in scar tissue is negligible, wash- 15 Several tracer kinetic models for quantification of MBF out of H2 O (on which the model for the computation of have been successfully validated in animals against the MBF is based) will mainly reflect activity in better-perfused radiolabeled microsphere gold standard over a wide flow segments and the resulting flow can therefore be higher than 15 13 13 range for both H2 O and NH3. The latter has also been that obtained with NH3 in the same region (54). validated against the argon gas technique in humans (41). The PET cameras used for the quantification of MBF, as Single-compartment models, based on Kety’s model for an well as for other cardiac PET applications, work in 2-di- inert freely diffusible tracer (42), are used for estimation of mensional (2D) mode with collimating septa between the 15 MBF using H2 O(12,14,15,43). A 3-compartment model detector rings to reduce the number of interplane scattered describing the kinetics of the myocardial metabolic trapping photons (55). A new generation of 3-dimensional (3D)-only 13 and whole-body metabolism of NH3 has been used for tomograms has become available with potential benefits calculation of MBF using this tracer (21,23,44–46). The over the 2D systems, particularly a higher efficiency. Re- 15 models have to include corrections for underestimation of cently, absolute quantification of MBF with H2 O and 3D radiotracer concentration due to the partial-volume effect PET has been validated in experimental animals (53). and spillover from the left chamber onto the ventricular myocardium (44,47), which result from the limited spatial resolution of the PET camera and the motion of the heart. APPLICATIONS OF PET TO STUDY CARDIAC PHYSIOLOGY AND PATHOPHYSIOLOGY Additional corrections have been developed to account for 13 the impact of flow (20) on myocardial extraction of NH3 Coronary flow reserve (CFR), the ratio of MBF during 13 and for the radiolabeled metabolites (48)of NH3, which near-maximal coronary vasodilation to basal MBF, is an accumulate in blood. integrated measure of flow through both the large epicardial 15 13 The equivalence of H2 O and NH3 as perfusion tracers coronary arteries and the microcirculation and has been has been demonstrated in experimental animals (49) and in proposed as an indirect parameter to evaluate the function of humans (50), but the proof of congruence of the tracers in the coronary circulation. An abnormal CFR can be due to ischemic and infarcted segments requires further investiga- narrowing of the epicardial coronary arteries or, in the 15 tion. The use of H2 O as a perfusion tracer is potentially absence of angiographically demonstrable atherosclerotic 13 15 superior to NH3 because H2 O is metabolically inert and disease, may reflect dysfunction of the coronary microcir- freely diffusible across capillary and sarcolemmal mem- culation. The latter can be caused by structural (e.g., vas- branes. Thus, it equilibrates rapidly between the vascular cular remodeling with reduced lumen-to-wall ratio) or func- and extravascular spaces and its uptake by the heart does not tional (e.g., vasoconstriction) changes, which may involve vary despite wide variations in flow rate. The short half-life neurohumoral factors or endothelial dysfunction. Further- (123 s) of 15O allows repetitive MBF measurements at short more, an abnormal CFR may also reflect changes in coro- intervals (10 min, equivalent to 5 half lives of 15O). Previ- nary or systemic hemodynamics as well as changes in 15 ously, an important shortcoming of the H2 O technique was extravascular coronary resistance (e.g., increased intramyo- its need for additional 15O-carbon monoxide (C15O) blood- cardial pressure).
Recommended publications
  • PET/CT Evaluation of Cardiac Sarcoidosis
    PET/CT Evaluation of Cardiac Sarcoidosis John P. Bois, MDa,*, Daniele Muser, MDb,1, Panithaya Chareonthaitawee, MDa KEYWORDS Cardiac sarcoidosis Positron emission tomography Fluorine-18 deoxyglucose KEY POINTS Sarcoidosis can involve the heart at with resultant significant morbidity and mortality. PET/CT is the most accurate method by which to diagnose cardiac sarcoidosis. Patient preparation prior to the PET/CT cardiac sarcoid study is critical to ensure diagnostic images are obtained. PET/CT detection of both active inflammation and scar has diagnostic, prognostic, and therapeutic importance. Ongoing areas of research include the use of PET to quantify the extent of myocardial inflammation and the discrepancies in myocardial blood flow in the cardiac sarcoidosis population. INTRODUCTION experiencing spontaneous remission and the remaining one-third developing either a stable or The increasing implementation of advanced car- progressive course.3 diovascular imaging in the form of cardiac PET/ The rate of cardiac involvement by sarcoidosis, CT has had a significant impact on the manage- otherwise termed CS, is variable and ranges ment of cardiac sarcoidosis (CS), one that con- from 20% to 75%.4,5 Furthermore, CS accounts tinues to evolve. Sarcoidosis is characterized for one-fourth of sarcoid-related mortality in the histologically by the presence of noncaseating United States and upward of 85% of death attrib- granulomas, with a predilection for the pulmonary uted to sarcoidosis in the Japanese population.4,6 system but with the ability to involve nearly every The high rate of involvement of the cardiovascular organ. Although the development of sarcoidosis system by sarcoidosis coupled with the potential is believed the sequelae of an exaggerated im- lethal outcomes has rendered accurate and timely mune or inflammatory response to an inciting in- diagnosis of this disease entity as imperative to fectious or environmental trigger, the specific patient care.
    [Show full text]
  • Myocardial Perfusion Imaging with PET
    SPECIAL CONTRIBUTION Myocardial Perfusion Imaging with PET Markus Schwaiger Nuklearmedizinische Klinik und Poliklini/çDer Technischen Universitdt Munchen, Klini/wm Rechts der Isar, Munich, Germany SPEC!' (5). PET spatial resolution is superior to that of AlthoughSPECThas become an acceptedimagingtechnique SPECT, resulting in superior image quality and less partial formyocardialperfusionstudies,thereare severaladvantages volume effect (5). Most PET images are processed with a to evaluatingcoronaryarterydisease (CAD)withPET.CADis a spatial resolution of about 6—10mm, as compared with complex, dynamic disease and quantitativemeasurements of 10—15mm for SPECF image reconstruction. myocardialbloodflowby PET can improvethe fUnCtiOnalchar The majoradvantageof PET is its ability to correct for acterizationof CAD.The majoradvantage of PET over SPECT attenuation.Traditionalmyocardialperfusionimagingwith is @rtsabilityto provideattenuation-correctedimages, whichde single-photon radiotracers such as 201'flposes significant creases incidenceof attenuation artifactsand increases spea challenges in avoiding or identifying and correcting for flcfty.Myocardialpertusion imagingwithPET can also provide moreaccurateinformationon localizationofdisease, as wellas attenuation artifacts, particularly those that involve the quantitativeassessment, inabsolutevalues, ofmyocardialblood inferior wall in male patients and the anterior wall in female flow.The measurement ofregionalflowreserve allowsforphys patients (6,7). iologiccharacterizationof stenosis severity,
    [Show full text]
  • Time-Of-Flight PET Map out Goals by Joel S
    Volume 3, Issue 4 FALL 2006 pet center of excellence newsletter PET COE Board Meets with Industry Advisory Group to Time-of-Flight PET Map Out Goals By Joel S. Karp, PhD he idea to use time-of-flight (TOF) information in PET image reconstruction By James W. Fletcher, MD Twas originally proposed in the 1960s at a very early stage in the development of President, PET Center of Excellence positron imaging. By the early 1980s, fully functional TOF PET systems had been built, An inaugural meet- not long after the first conventional PET systems were completed. Why then did it take ing was held recently so long to introduce a clinical TOF PET scanner, and how does it compare to the first in Chicago between the TOF PET instruments built 25 years ago? PET Center of Excel- Time-of-Flight Theory lence Board of Directors The concept of time-of-flight means simply that for each annihilation event, we note (BOD) and the Industry the precise time that each of the coincident photons is detected and calculate the dif- Advisory Group (IAG). ference. Since the closer photon will arrive at its detector first, the difference in arrival The meeting was very times helps pin down the location of the annihilation event along the line between the James W. Fletcher well attended with rep- two detectors. resentation from a large To understand why this information is useful, we need to recall that normally in cross-section of industry. PET we collect line pair data at many angles and create tomographic images through The interaction and discussion at the con- traditional filtered back-projection or through an iterative series of back- and forward- joint morning meeting was lively and infor- projection steps.
    [Show full text]
  • Atrium Health Delineation of Privileges Specialty of Radiology
    ATRIUM HEALTH DELINEATION OF PRIVILEGES SPECIALTY OF RADIOLOGY Print Name YES NO** I have participated in direct patient care in the hospital setting within the past two (2) years. **If the answer is No, please do not complete this form. Contact the Medical Staff Office at (704) 355-2147 for additional instructions regarding the required proctoring process. Initial appointment Reappointment Updated DOP Request for Clinical Privileges To be eligible for core privileges in Radiology, the applicant must meet the following qualifications: If the applicant is not currently certified in Radiology by the American Board of Medical Specialties (ABMS) or the American Osteopathic Association (AOA) the applicant must: 1. Provide documentation of successful completion of an ACGME or AOA accredited Radiology training program, within the past five (5) years; AND 2. Provide documentation of the performance and interpretation of at least five-thousand (5,000) imaging tests in the past two (2) years. Applicants have the burden of producing information deemed adequate by the hospital for proper evaluation of current competence, and other qualifications and for resolving any doubts; OR If the applicant is currently certified in Radiology by the American Board of Medical Specialties (ABMS) or the American Osteopathic Association (AOA), the applicant must: 1. Provide documentation of general pediatric certification from the American Board of Medical Specialties or the American Osteopathic Association (AOA); AND 2. Provide documentation of the performance and interpretation of at least five-thousand (5,000) imaging tests in the past two (2) years. Applicants have the burden of producing information deemed adequate by the hospital for proper evaluation of current competence, and other qualifications and for resolving any doubts.
    [Show full text]
  • Cardiac Radiology)
    CAE002-b F-18 FDG PET/CT and MRI In the Diagnosis and Management of Cardiac Sarcoidosis Education Exhibits Location: CA Community, Learning Center Participants Richard Anthony R. Coulden MD (Presenter): Nothing to Disclose Emer Sonnex : Nothing to Disclose Hefin Jones FRCR : Nothing to Disclose Indrajeet Das MBBCh, MRCP : Nothing to Disclose Jonathan Thomas Abele MD : Nothing to Disclose TEACHING POINTS In patients with established non-cardiac sarcoidosis, both FDG PET/CT and cardiac MRI can be used to diagnose cardiac involvement. We will learn how and why: 1. FDG PET/CT identifies active disease and can be used in both diagnosis and management. Serial PET allows assessment of response to immunosuppressive treatment. 2. Cardiac MRI identifies myocardial edema and scar. It has proven value in diagnosis but its role in monitoring disease in response to treatment is unclear. 3. Cardiac MRI provides additional value in assessment of ventricular volumes and function and maybe a helpful surrogate in monitoring treatment response. 4. FDG PET/CT and MRI are complementary techniques. TABLE OF CONTENTS/OUTLINE 1. Criteria for clinical diagnosis of cardiac sarcoidosis (Japanese Ministry of Health and Welfare) 2. How to use FDG PET/CT for inflammatory cardiac imaging 3. How to use cardiac MRI for infiltrative cardiomyopathies 4. Relative roles of Cardiac MRI and FDG PET/CT in: a. the imaging diagnosis of cardiac sarcoidosis b. follow-up of disease activity and response to immunosuppressive treatment. CAE004-b Dynamic Myocardial Perfusion Imaging by 3rd Generation Dual-Source CT Education Exhibits Location: CA Community, Learning Center Participants Marisa Marjolein Lubbers MD (Presenter): Nothing to Disclose Adriaan Coenen MD : Nothing to Disclose Akira Kurata : Nothing to Disclose Marcel L.
    [Show full text]
  • Evicore Cardiac Imaging Guidelines
    CLINICAL GUIDELINES Cardiac Imaging Policy Version 1.0 Effective February 14, 2020 eviCore healthcare Clinical Decision Support Tool Diagnostic Strategies: This tool addresses common symptoms and symptom complexes. Imaging requests for individuals with atypical symptoms or clinical presentations that are not specifically addressed will require physician review. Consultation with the referring physician, specialist and/or individual’s Primary Care Physician (PCP) may provide additional insight. CPT® (Current Procedural Terminology) is a registered trademark of the American Medical Association (AMA). CPT® five digit codes, nomenclature and other data are copyright 2017 American Medical Association. All Rights Reserved. No fee schedules, basic units, relative values or related listings are included in the CPT® book. AMA does not directly or indirectly practice medicine or dispense medical services. AMA assumes no liability for the data contained herein or not contained herein. © 2019 eviCore healthcare. All rights reserved. Cardiac Imaging Guidelines V1.0 Cardiac Imaging Guidelines Abbreviations for Cardiac Imaging Guidelines 3 Glossary 4 CD-1: General Guidelines 5 CD-2: Echocardiography (ECHO) 15 CD-3: Nuclear Cardiac Imaging 26 CD-4: Cardiac CT, Coronary CTA, and CT for Coronary Calcium (CAC) 33 CD-5: Cardiac MRI 40 CD-6: Cardiac PET 45 CD-7: Diagnostic Heart Catheterization 49 CD-8: Pulmonary Artery and Vein Imaging 56 CD-9: Congestive Heart Failure 59 CD-10: Cardiac Trauma 62 CD-11: Adult Congenital Heart Disease 64 CD-12: Cancer Therapeutics-Related
    [Show full text]
  • Myocardial Perfusion Imaging Versus CT Coronary Angiography: When to Use Which?
    CONTINUING EDUCATION Myocardial Perfusion Imaging Versus CT Coronary Angiography: When to Use Which? Balaji Tamarappoo and Rory Hachamovitch Section of Cardiovascular Imaging, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio Learning Objectives: On successful completion of this activity, participants should be able to describe (1) the various types of noninvasive cardiac imaging tests and how the results of each are utilized; (2) recent advances in CT coronary angiography, PET myocardial perfusion imaging, and SPECT myocardial perfusion imaging of coronary artery disease; and (3) the clinical use of anatomic versus physiologic tests in symptomatic patients with known or suspected coronary artery disease. Financial Disclosure: The authors of this article have indicated no relevant relationships that could be perceived as a real or apparent conflict of interest. CME Credit: SNM is accredited by the Accreditation Council for Continuing Medical Education (ACCME) to sponsor continuing education for physicians. SNM designates each JNM continuing education article for a maximum of 1.0 AMA PRA Category 1 Credit. Physicians should claim only credit commensurate with the extent of their participation in the activity. For CE credit, participants can access this activity through the SNM Web site (http://www.snm.org/ce_online) through June 2012. suspected coronary artery disease (CAD). The results of Both anatomy- and physiology-based approaches to patient these tests are used for patient risk stratification, evaluation management have advantages and limitations. Compared of myocardial ischemia as a cause of symptoms, and assess- with the latter, the former has a superior ability to exclude ment of ongoing disease management. Stress myocardial disease and does not miss high-risk coronary artery disease (CAD).
    [Show full text]
  • Pet/Ct) Imaging
    The American College of Radiology, with more than 30,000 members, is the principal organization of radiologists, radiation oncologists, and clinical medical physicists in the United States. The College is a nonprofit professional society whose primary purposes are to advance the science of radiology, improve radiologic services to the patient, study the socioeconomic aspects of the practice of radiology, and encourage continuing education for radiologists, radiation oncologists, medical physicists, and persons practicing in allied professional fields. The American College of Radiology will periodically define new practice parameters and technical standards for radiologic practice to help advance the science of radiology and to improve the quality of service to patients throughout the United States. Existing practice parameters and technical standards will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice parameter and technical standard, representing a policy statement by the College, has undergone a thorough consensus process in which it has been subjected to extensive review and approval. The practice parameters and technical standards recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice parameter and technical standard by those entities not providing these services is not authorized. Adopted 2017 (Resolution 26)* ACR–SPR–STR PRACTICE PARAMETER FOR THE PERFORMANCE OF CARDIAC POSITRON EMISSION TOMOGRAPHY - COMPUTED TOMOGRAPHY (PET/CT) IMAGING PREAMBLE This document is an educational tool designed to assist practitioners in providing appropriate radiologic care for patients. Practice Parameters and Technical Standards are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care1.
    [Show full text]
  • 2009 Appropriate Use Critera for Cardiac Radionuclide Imaging
    Appropriate Use Criteria for Cardiac Radionuclide Imaging Ratings Moderator 1 2 3 4 5 6 7 8 9 101112131415 Indication Median MADM R Agree Table 1. Detection of CAD: Symptomatic Evaluation of Ischemic Equivalent (Non-Acute) 1 • Low pre-test probability of CAD 4 2 1 5 1 3 4 2 1 5 3 2 4 3 3 3 1.1 I • ECG interpretable AND able to exercise 2 • Low pre-test probability of CAD 9 7 3 9 5 7 6 7 7 8 8 8 7 7 5 7 1.1 A + • ECG uninterpretable OR unable to exercise 3 • Intermediate pre-test probability of CAD 9 728173788877 7 7 7 1.4 A + • ECG interpretable AND able to exercise 4 • Intermediate pre-test probability of CAD 9 9 8 9 7 8 9 9 99 9 9 9 9 9 9 0.3 A + • ECG uninterpretable OR unable to exercise 5 • High pre-test probability of CAD 9 9 59 5 8 6 8 7 5 8 7 6 8 9 8 1.3 A • Regardless of ECG interpretability and ability to exercise Acute Chest Pain 6 • Possible ACS 9 9 8 8 7 8 7 8 3 8 7 8 7 8 6 8 0.9 A + • ECG—no ischemic changes or with LBBB or electronically paced ventricular rhythm • Low-Risk TIMI Score • Peak Troponin: borderline, equivocal, minimally elevated 7 • Possible ACS 9 8 1 9 2 8 5 8 1 7 7 7 5 8 9 7 2.1 A • ECG—no ischemic changes or with LBBB or electronically paced ventricular rhythm • High-Risk TIMI Score • Peak Troponin: borderline, equivocal, minimally elevated 8 • Possible ACS 9 8 9 9 3 7 3 8 8 8 7 8 8 7 4 8 1.3 A + • ECG—no ischemic changes or with LBBB or electronically paced ventricular rhythm • Low-Risk TIMI Score • Negative troponin levels 9 • Possible ACS 9 9 8 9 7 5 7 9 1 8 6 7 8 8 8 8 1.3 A + • ECG—no ischemic changes or with LBBB or electronically paced ventricular rhythm • High-Risk TIMI Score • Negative troponin levels 10 • Definite ACS 111312111111122 1 0.3 I + Acute Chest Pain (Rest Imaging Only) 11 • Possible ACS 9 9 7 7 7 2 68 9 2 8 6 8 8 6 7 1.5 A • ECG—no ischemic changes or with LBBB or electronically paced ventricular rhythm • Initial troponin negative • Recent or on-going chest pain Table 2.
    [Show full text]
  • A Patient's Guide to Cardiac PET Imaging
    A Patient’s Guide to Cardiac PET Imaging What to expect and how to prepare for your exam How do I prepare for the cardiac PET exam?1 Knowing what to expect ahead of time will make your experience easier. Ask your doctor for specific instructions to prepare for your exam, as well as how long it might take. You may be asked to make a few important changes Image courtesy of GE Healthcare before the exam: • You may be asked to temporarily stop taking certain medications. It is very important that you check with What is a cardiac your doctor BEFORE discontinuing any medication. PET exam? • You may be asked to not eat or drink anything for a period of time before your exam. Cardiac Positron Emission Tomography (PET) exams help • You may be asked to avoid consuming caffeine to evaluate heart health by measuring the blood flow products for at least 12-24 hours before your exam. brought by the coronary arteries to the heart muscle. For decades, doctors have used cardiac PET scans to safely and accurately identify the presence or absence of coronary You may be asked to provide some important artery disease in people who have had symptoms and/or information: risk factors. Exam results can also indicate if any follow-up • You will be asked if you have any allergies. Please be treatment is needed. If you are already being treated for a prepared to discuss this with the supervising doctor. heart-related condition, your doctor can also use the results • Plan to bring a list of all your medications to the exam.
    [Show full text]
  • PET/CT in Cardiac Imaging
    PET/CT in cardiac imaging Raffaele Giubbini Chair of Nuclear Medicine and Nuclear Medicine Unit University and Spedali Civili – Brescia, Italy [email protected] Hybrid Imaging: Providing• Any simple combination and accurate of structuralintegrated and measure functional of the effect of informationanatomic stenosis on coronary resistance and tissue perfusion. OptimizingCardiac selection Hybrid of patients Imaging: who may ultimately benefit from revascularization • The combination of two data sets in equally importance for the integration of one final image. • Referred to functional (PET/SPECT) and anatomical evaluation through Cardiac Computed Tomography Angiography (CCTA). Myocardial Endothelial Function Perfusion Correlation CCTA - PET Myocardial Viability Cardiac Inflammation of the Function atherosclerotic plaque Myocardial Molecular Imaging Blood Flow WHERE do we stand? • TheThe currentlimitations evidence forof anatomicmorphologic evaluation measures using for CCTAdelineating remarks its: the physiologic implications of– Highstenosis negative predictiveare well describedvalue i. e. The– Moderate vasomotor good capacitytone and to coronary collateral flow, bothpredict of which a >50% are coronary known to arteryaffect lesion myocardial • Makingperfusion it ,a verycannot reliable be estimated by measures of formstenosis to excludeseverity . significant CAD. WHERE do we stand? • It has been previously described that the majority of patients are referred to diagnostic invasive coronary angiography and consequently to PCI in the
    [Show full text]
  • PET Coding Review and Resources
    Volume 3, Issue 3 SUMMER 2006 pet center of excellence newsletter SNM Members Appointed to National Academy of Sciences PET Coding Review Committee to Review State of Nuclear Medicine and Resources By Denise A. Merlino, MBA, CNMT, CPC, FSNMTS Peter S. Conti, immediate past president of ET is a technology that continues to evolve, and coding, coverage, and payment both SNM and the PET Center of Excellence, Psystems have been evolving along with it. In March of 2005, PET providers and a number of other SNM members were transitioned from using complicated “G” series Healthcare Common Procedure Cod- recently named to the National Academy of ing System (HCPCS) codes to the American Medical Association (AMA) Current Sciences (NAS) ad hoc committee of experts Procedural Terminology (CPT) codes for Medicare-covered indications. Last January, to review the “state of the science” for nuclear PET radiopharmaceutical HCPCS codes were changed for FDG and rubidium. Finally, medicine. in May, the National Oncologic PET Registry (NOPR) went into operation providing “The 13-month $700,000 study will pro- Medicare coverage of FDG PET studies for all cancer indications that did not fall under vide the opportunity to validate the importance the current national coverage determination (NCD) policy. of basic nuclear medicine research,” said Every change brings with it the need to train staff, update billing software, and make Conti, a professor of radiology, pharmacy and certain that all billing procedures are in compliance with the new regulations. The list biomedical engineering at the University of below summarizes the top 10 things you need to know about coding PET today.
    [Show full text]