North Pine Dam Manual of Operational Procedures

Total Page:16

File Type:pdf, Size:1020Kb

North Pine Dam Manual of Operational Procedures North Pine Dam Manual of Operational Procedures for Flood Mitigation Revision 10 | November 2019 Revision No. Date Amendment Details 0 10 December 1986 Original Issue 1 6 October 1992 Complete revision and re-issue 2 13 November 1997 Complete revision and re-issue 3 26 July 2002 Complete revision and re-issue 4 5 September 2007 Complete revision and re-issue 5 August 2010 (approved by gazette Complete revision and re-issue notice dated 17 December 2010) 6 October 2011 Revision 7 October 2012 Minor revision only 8 November 2013 Revision 9 November 2014 Revision based on outcomes of the North Pine Dam Optimisation Study and Government policy decision 10 November 2019 Revision Revision No: 10 – November 2019 Doc No: MAN-00160 Manual of Operational Procedures for Flood Mitigation at North Pine Dam 1 TABLE OF CONTENTS Table of Contents Table of Contents .............................................................................................................................................................. 2 Glossary ............................................................................................................................................................................. 4 Preface ............................................................................................................................................................................... 8 1. Introduction .................................................................................................................................................................. 9 1.1 Purpose ............................................................................................................................................................. 9 1.2 Application Exclusions ........................................................................................................................................ 9 1.3 Agency Responsibilities ..................................................................................................................................... 9 1.4 Legal Authority ................................................................................................................................................. 10 1.5 Document Control ............................................................................................................................................ 10 1.6 Significant Changes in this Revision ................................................................................................................ 10 2. Procedural Matters .................................................................................................................................................... 11 2.1 Operational Arrangements ............................................................................................................................... 11 2.2 Responsibilities of the DSFOE ......................................................................................................................... 11 2.3 Responsibilities of a Duty Flood Operations Engineer ..................................................................................... 12 2.4 Responsibilities of Flood Officers ..................................................................................................................... 12 2.5 Responsibilities of Dam Supervisors ................................................................................................................ 12 2.6 Responsibilities of Dam Operators ................................................................................................................... 13 2.7 Qualifications, Experience and Training of Flood Operations Staff ................................................................. 13 2.8 Maintaining and Improving the FFS.................................................................................................................. 15 2.9 Maintenance of Communications Equipment ................................................................................................... 15 3. Flood Mitigation Objectives ...................................................................................................................................... 16 3.1 Introduction ...................................................................................................................................................... 16 3.2 Flood Mitigation Objectives .............................................................................................................................. 16 3.3 Prevent structural failure of the Dam ................................................................................................................ 16 3.4 Ensure the Dam’s Water Supply Compartment is full at the completion of the Flood Event ............................ 18 3.5 Mitigate Downstream Flooding ......................................................................................................................... 19 3.6 Protect the Environment ................................................................................................................................... 19 4. Flood Operations Overview ...................................................................................................................................... 21 4.1 Introduction ...................................................................................................................................................... 21 4.2 Flood Operations Centre Mobilisation and Demobilisation ............................................................................... 21 4.3 Flood Event Commencement and Ending ........................................................................................................ 21 4.4 Operational Strategy Selection and Release Plan Development ..................................................................... 22 4.5 Use of Rainfall Forecasts ................................................................................................................................. 22 4.6 Consideration of Forecast Rainfall in Flood Operations Centre Mobilisation .................................................... 23 4.7 Consideration of Forecast Rainfall in judging whether Rainfall is Complete or Nearly Complete ..................... 24 4.8 Consideration of Forecast Rainfall in developing a Release Plan .................................................................... 24 4.9 Consideration of Forecast Rainfall in Emergency Response ........................................................................... 25 Revision No: 10 – November 2019 Doc No: MAN-00160 Manual of Operational Procedures for Flood Mitigation at North Pine Dam 2 TABLE OF CONTENTS 4.10 Alternative Procedures ..................................................................................................................................... 25 4.11 Implementing the Release Plan ....................................................................................................................... 27 4.12 Bridge Closure Advice ...................................................................................................................................... 27 5. North Pine Dam Flood Operations ........................................................................................................................... 28 5.1 Flood Release Infrastructure ............................................................................................................................ 28 5.2 Flood Operations Procedures .......................................................................................................................... 29 5.3 Radial Gate Operation ...................................................................................................................................... 32 6. Emergency Flood Operations ................................................................................................................................... 33 6.1 Introduction ...................................................................................................................................................... 33 6.2 Dam Failure Considerations ............................................................................................................................. 33 6.3 Dam Operator Actions in the Event of Communications Failure ...................................................................... 33 6.4 Equipment Failure ............................................................................................................................................ 35 6.5 Failure of the FFS ............................................................................................................................................. 35 7. Declarations of Temporary Full Supply Levels for Flood Mitigation or the application of a Reduced Full Supply Level .................................................................................................................................................................... 36 7.1 Glossary ........................................................................................................................................................... 36 7.2 Purpose ............................................................................................................................................................ 36 7.3 Application .......................................................................................................................................................
Recommended publications
  • Water for South East Queensland: Planning for Our Future ANNUAL REPORT 2020 This Report Is a Collaborative Effort by the Following Partners
    Water for South East Queensland: Planning for our future ANNUAL REPORT 2020 This report is a collaborative effort by the following partners: CITY OF LOGAN Logo guidelines Logo formats 2.1 LOGO FORMATS 2.1.1 Primary logo Horizontal version The full colour, horizontal version of our logo is the preferred option across all Urban Utilities communications where a white background is used. The horizontal version is the preferred format, however due to design, space and layout restrictions, the vertical version can be used. Our logo needs to be produced from electronic files and should never be altered, redrawn or modified in any way. Clear space guidelines are to be followed at all times. In all cases, our logo needs to appear clearly and consistently. Minimum size 2.1.2 Primary logo minimum size Minimum size specifications ensure the Urban Utilities logo is reproduced effectively at a small size. The minimum size for the logo in a horizontal format is 50mm. Minimum size is defined by the width of our logo and size specifications need to be adhered to at all times. 50mm Urban Utilities Brand Guidelines 5 The SEQ Water Service Provider Partners work together to provide essential water and sewerage services now and into the future. 2 SEQ WATER SERVICE PROVIDERS PARTNERSHIP FOREWORD Water for SEQ – a simple In 2018, the SEQ Water Service Providers made a strategic and ambitious statement that represents decision to set out on a five-year journey to prepare a holistic and integrated a major milestone for the plan for water cycle management in South East Queensland (SEQ) titled “Water region.
    [Show full text]
  • Fact Sheet Wivenhoe Dam
    Fact sheet Wivenhoe Dam Wivenhoe Dam Wivenhoe Dam’s primary function is to provide a safe drinking Key facts water supply to the people of Brisbane and surrounding areas. It also provides flood mitigation. Name Wivenhoe Dam (Lake Wivenhoe) Watercourse Brisbane River The water from Lake Wivenhoe, the reservoir formed by the dam, is stored before being treated to produce drinking water Location Upstream of Fernvale and follows the water journey of source, store and supply. Catchment area 7020.0 square kilometres Length of dam wall 2300.0 metres Source Year completed 1984 Wivenhoe Dam is located on the Brisbane River in the Somerset Type of construction Zoned earth and rock fill Regional Council area. embankment Spillway gates 5 Water supply Full supply capacity 1,165,238 megalitres Wivenhoe Dam provides a safe drinking water supply for Flood mitigation 1,967,000 megalitres Brisbane, Ipswich, Logan, Gold Coast, Beaudesert, Esk, Gatton, Laidley, Kilcoy, Nanango and surrounding areas. The construction of the dam involved the placement of around 4 million cubic metres of earth and rock fill, and around 140,000 Wivenhoe Dam was designed and built as a multifunctional cubic metres of concrete in the spillway section. Excavation facility. The dam was built upstream of the Brisbane River, of 2 million cubic metres of earth and rock was necessary to 80 kilometres from Brisbane City. At full supply level, the dam construct the spillway. holds approximately 2,000 times the daily water consumption needed for Brisbane. The Brisbane Valley Highway was relocated to pass over the dam wall, while 65 kilometres of roads and a number of new Wivenhoe Dam, along with the Somerset, Hinze and North Pine bridges were required following construction of the dam.
    [Show full text]
  • First Defendant's Cross-Claim
    Form 9 (version 5) UCPR 9.1 FIRST CROSS-CLAIM STATEMENT OF CROSS.CLAIM Court Supreme Court New South Wales Division Common Law Division List not applicable Registry Sydney Case number No 200854 of 2014 Plaintiff RodriEuez & Sons Ptv Limited (ACN 108 770 681ì First defendant Queensland Bulk Water Supplv Authoritv. tradins ae Seqwater Number of defendants g Cross-claimant Seqwater First cross-defendant SunWater Limited ACN l3l 034 985 Second cross-defendant State of Queensland Filed for Queensland Bulk Water Supply Authority, trading as Seqwater, the First Defendant Filed in relation to the First Defendant's cross-claim Legal representative Justin McDonnell Legal representative reference JAM/NC 0455057758 Contact name and telephone Justin McDonnell (07) 3244 8099 Contact email [email protected] 21069319:) I 2 1 Damages. 2 Further or alternatively to paragraph 1, contribution under section 6 of the Law Reform Act rees (ord). 3 lnterest in accordance with s 100 of lhe Civil Procedure Act 2005 (NSW). 4 Costs. A Parties 1 At all material times the Queensland Bulk Water Supply Authority trading as Seqwater (Seqwater): (a) was an entity established under section 6 of the South East Queensland Water (Restructuring) Act 2007 (ald); (b) was not a body corporate; and (c) was capable of suing and being sued. 2 Atall materialtimes SunWater Limited ACN 131 034 985 (SunWater): (a) was a government owned corporation within the meaning of section 5 of the Government Owned Corporations Acf 1993 (Qld); (b) was a registered public company limited by shares; and (c) was capable of being sued 3 At all materialtimes the State of Queensland was capable of being sued in accordance with section 8 of the Crown Proceedings Acf 1980 (Qld).
    [Show full text]
  • Barton Maher Annex Bm4o.PDF
    Preparedby: SunWaterLimited ACN131034985 179TurbotStreet Brisbane PO Box 15536CityEast BrisbaneQueenslandAustralia4002 Tel: +61731200153 Fax:+61731200242 Author: MrRobA~ SeniorFloodOperationsEngineerRPEQ4887 AssetSolutions Approved: rir &gden Manager- EngineeringDesign,South AssetSolutions Preparedfor: Seqwater This reporthas been producedby SunWater,to provideinformationfor client use only. The informationcontainedin this reportis limitedbythe scope andthe purposeof the engineeringstudy,and shouldnot be regardedas completelyexhaustive. Permissionto useor quoteinformationfromthis reportin studiesexternalto the Corporationmustfirst be obtainedfromthe Chief Executive,SunWater. TRAINING & FLOOD PREPAREDNESS FOR SEQWATER DAMS FOR THE YEAR BEGINNING 30 SEPTEMBER 2009 TABLE OF CONTENTS 1.0 INTRODUCTION ..................................................................................................1 2.0 REPORT ON FLOOD PREPAREDNESS FOR 2009/2010 ..................................3 2.1 STATUS OF STORAGES ............................................................................................ 3 2.2 ARRANGEMENT OF FLOOD RESPONSE TEAMS.................................................... 4 2.3 FLOOD OPERATION CENTRE PREPAREDNESS..................................................... 5 2.3.1 Flood Operation Centre, Level 9 179 Turbot Street...............................................................5 3.0 REAL TIME FLOOD MODEL PREPAREDNESS ................................................7 3.1 CURRENT PLATFORM ..............................................................................................
    [Show full text]
  • Appendix 8.1 Capital Expenditure Disclosures for the Grid Service Charges Information Returns 2012-2013
    Appendix 8.1 Capital Expenditure Disclosures for the Grid Service Charges Information Returns 2012-2013 Seqwater Capital Expenditure 2011-2012 Project ID Project Description Asset Name and Type Asset Location Construction Start/ Acquisition Date Commissioning Date New/ Ongoing life Asset Opening Balance 2011-12 2011-12 Interest Capitalised Total Capital Cost WTP, Dam, Pipeline Years QCA approval Est Act Seqwater Drought Infrastructure Capitalised by 30 June 2012 C201000217 Wyaralong Dam Acquisition (see Note 1 below) Wyaralong Dam Beaudesert Jul-11 Jul-11 New 150 373,473,000 373,427,243 - 373,427,243 C201000119 Wyaralong Dam - transfer - owner costs Wyaralong Dam Beaudesert Jul-11 Jul-11 New 150 385,000 400,000 365,000 - 750,000 C200900032 Hinze Dam Stage 3 (Construction) Hinze Dam Nerang Pre 1-Jul-11 Nov-11 New 150 371,502,000 11,300,000 13,949,376 57,986,000 443,437,376 Hinze Dam Stage 3 - Land Hinze Dam Nerang Pre 1- Jul-12 Nov- 11 New 0 - 8,950 , 000 8,950 , 000 - 8,950 , 000 C200900032 Hinze Dam Stage 3 (Defects Liability) Hinze Dam Nerang Pre 1-Jul-11 Jun-12 New 150 10,000,000 9,968,970 - 9,968,970 C200900085 Ewen Maddock WTP Upgrade Ewen Maddock WTP Sunshine Coast Jul-11 Jun-12 Ongoing 30 100,000 260,000 - 260,000 Total Seqwater Drought Infrastructure Capitalised by 30 June 2012 404,223,000 406,920,589 57,986,000 836,793,589 Approved Seqwater Non-drought Infrastructure Capitalised by 30 June 2012 C201000232 Mt Crosby WTPs Critical Chemical Dosing Systems Mt Crosby WTPs Mt Crosby Jul-11 Jun-12 Ongoing 20 705,000 705,000 - 705,000
    [Show full text]
  • Rising to the Challenge
    Rising to the challenge Annual Report 2010-11 14 September 2011 This Annual Report provides information about the financial and non-financial performance of Seqwater for 2010-11. The Hon Stephen Robertson MP It has been prepared in accordance with the Financial Minister for Energy and Water Utilities Accountability Act 2009, the Financial and Performance PO Box 15216 Management Standard 2009 and the Annual Report City East QLD 4002 Guidelines for Queensland Government Agencies. This Report records the significant achievements The Hon Rachel Nolan MP against the strategies and activities detailed in the Minister for Finance, Natural Resources and the Arts organisation’s strategic and operational plans. GPO Box 611 This Report has been prepared for the Minister for Brisbane QLD 4001 Energy and Water Utilities to submit to Parliament. It has also been prepared to meet the needs of Seqwater’s customers and stakeholders, which include the Federal and local governments, industry Dear Ministers and business associations and the community. 2010-11 Seqwater Annual Report This Report is publically available and can be viewed I am pleased to present the Annual Report 2010-11 for and downloaded from the Seqwater website at the Queensland Bulk Water Supply Authority, trading www.seqwater.com.au/public/news-publications/ as Seqwater. annual-reports. I certify that this Annual Report meets the prescribed Printed copies are available from Seqwater’s requirements of the Financial Accountability Act 2009 registered office. and the Financial and Performance Management Standard 2009 particularly with regard to reporting Contact the Authority’s objectives, functions, performance and governance arrangements. Queensland Bulk Water Authority, trading as Seqwater.
    [Show full text]
  • Drinking Water Quality Management Plan Lakes Wivenhoe and Somerset, Mid-Brisbane River and Catchments
    Drinking Water Quality Management Plan Lakes Wivenhoe and Somerset, Mid-Brisbane River and Catchments April 2010 Peter Schneider, Mike Taylor, Marcus Mulholland and James Howey Acknowledgements Development of this plan benefited from guidance by the Queensland Water Commission Expert Advisory Panel (for issues associated with purified recycled water), Heather Uwins, Peter Artemieff, Anne Woolley and Lynne Dixon (Queensland Department of Environment and Resource Management), Nicole Davis and Rose Crossin (SEQ Water Grid Manager) and Annalie Roux (WaterSecure). The authors thank the following Seqwater staff for their contributions to this plan: Michael Bartkow, Jonathon Burcher, Daniel Healy, Arran Canning and Peter McKinnon. The authors also thank Seqwater staff who contributed to the supporting documentation to this plan. April 2010 Q-Pulse Database Reference: PLN-00021 DRiNkiNg WateR QuALiTy MANAgeMeNT PLAN Executive Summary Obligations and Objectives 8. Contribute to safe recreational opportunities for SEQ communities; The Wivenhoe Drinking Water Quality Management Plan (WDWQMP) provides a framework to 9. Develop effective communication, sustainably manage the water quality of Lakes documentation and reporting mechanisms; Wivenhoe and Somerset, Mid-Brisbane River and and catchments (the Wivenhoe system). Seqwater has 10. Remain abreast of relevant national and an obligation to manage water quality under the international trends in public health and Queensland Water Supply (Safety and Reliability) water management policies, and be actively Act 2008. All bulk water supply and treatment involved in their development. services have been amalgamated under Seqwater as part of the recent institutional reforms for water To ensure continual improvement and compliance supply infrastructure and management in South with the Water Supply (Safety and Reliability) East Queensland (SEQ).
    [Show full text]
  • Flood Procedure Manual
    FLOOD PROCEDURE MANUAL WIVENHOE DAM SOMERSET DAM NORTH PINE DAM LESLIE HARRISON DAM UNCONTROLLED SPILLWAY DAMS Uncontrolled Copy 2•∂©≥©ØÆ *°Æµ°≤π Flood Operations Procedures REVISION STATUS Revision No. Date Amendment Details 0 January 2010 Uncontrolled Copy Date: January 2010 Flood Operations Procedures DISTRIBUTION LIST Agency Responsible Person Location Seqwater Dam and Source Operations Manager Margaret Street, Brisbane Seqwater Principal Engineer Dam Safety Karalee Seqwater Principal Hydrologist Margaret Street, Brisbane Seqwater Operations Coordinator, North Landers Shute Seqwater Operations Coordinator, Central Wivenhoe Dam Seqwater Operations Coordinator, South Karalee Seqwater Storage Supervisor Leslie Harrison Dam Seqwater Storage Supervisor North Pine Dam Seqwater Storage Supervisor Somerset Dam Seqwater Storage Supervisor Wivenhoe Dam Flood Operations Centre, Seqwater Senior Flood Operations Engineer Brisbane Uncontrolled Copy Date: January 2010 Flood Operations Procedures DEFINITIONS “Act” means the Water Supply (Safety and Reliability) Act 2008; “AEP” means annual exceedance probability, the probability of a specified event being exceeded in any year. “AHD” means Australian Height Datum; “Chairperson” means the Chairperson of Seqwater; “Close Call” means being able to be contacted at all times and being able to report for duties at a designated site within two hours of being contacted. “Controlled Document” means a document subject to managerial control over its contents, distribution and storage. It may have legal and contractual implications; “Dams” means dams to which these procedures apply, that is Wivenhoe Dam, Somerset Dam, North Pine Dam and Leslie Harrison Dam; “Dam Operator” means a person who has been trained and who is competent to release flood water from a dam and undertake all required Flood Event duties at a dam; “Dam Supervisor” means the senior on-site officer at a Dam; “Duty Flood Operations Engineer” outside a flood event means the Flood Operations Engineer currently on close call.
    [Show full text]
  • Fact Sheet Water Treatment Plant
    Fact sheet Water Treatment Plant About North Pine WTP The North Pine Water Treatment Plant (WTP) turns raw water Key facts into safe, drinkable water for the northern Brisbane and Moreton Bay regions. Name North Pine Water Treatment Plant Dam North Pine Dam (Lake Samsonvale) The treatment plant is located downstream and adjacent to the North Pine Dam and can treat up to 250 megalitres (ML) of Location Petrie water per day. Intake location North Pine Dam Catchment area 348.0 square kilometres Source Commenced operation 1974 The rain that falls on the catchment flows over an extensive Sedimentation basins 2 area and collects in North Pine Dam. This runoff carries soil, Depth of basins 3.66 metres pollutants, debris and micro-organisms into the creeks and Volume of basins 13.37 megalitres combined rivers that flow into the dam. Filter tanks 5 The water stored in North Pine Dam is pumped directly to the Total treated water 250 megalitres per day treatment plant as required, to be made safe for drinking. production capacity Storage capacity of 91 megalitres Treatment treated water Raw water is collected from the intake tower (also called an offtake tower) in the North Pine Dam wall, through a suction Treatment process tunnel pipeline. The raw water pumping station then lifts the water to the inlets of the treatment plant. Coagulation Powder activated carbon (PAC) is added to the water as To remove any dirt or other suspected material, raw water is it enters the plant to remove unwanted taste and odour pushed through a flash mixer.
    [Show full text]
  • An Economic Assessment of the Value of Recreational Angling at Queensland Dams Involved in the Stocked Impoundment Permit Scheme
    An economic assessment of the value of recreational angling at Queensland dams involved in the Stocked Impoundment Permit Scheme Daniel Gregg and John Rolfe Value of recreational angling in the Queensland SIP scheme Publication Date: 2013 Produced by: Environmental Economics Programme Centre for Environmental Management Location: CQUniversity Australia Bruce Highway North Rockhampton 4702 Contact Details: Professor John Rolfe +61 7 49232 2132 [email protected] www.cem.cqu.edu.au 1 Value of recreational angling in the Queensland SIP scheme Executive Summary Recreational fishing at Stocked Impoundment Permit (SIP) dams in Queensland generates economic impacts on regional economies and provides direct recreation benefits to users. As these benefits are not directly traded in markets, specialist non-market valuation techniques such as the Travel Cost Method are required to estimate values. Data for this study has been collected in two ways in 2012 and early 2013. First, an onsite survey has been conducted at six dams in Queensland, with 804 anglers interviewed in total on their trip and fishing experiences. Second, an online survey has been offered to all anglers purchasing a SIP licence, with 219 responses being collected. The data identifies that there are substantial visit rates across a number of dams in Queensland. For the 31 dams where data was available for this study, recreational anglers purchasing SIP licences have spent an estimated 272,305 days fishing at the dams, spending an average 2.43 days per trip on 2.15 trips per year to spend 4.36 days fishing per angler group. Within those dams there is substantial variation in total fishing effort, with Somerset, Tinaroo, Wivenhoe and North Pine Dam generating more than 20,000 visits per annum.
    [Show full text]
  • US EPA to Withdraw Arsenic Rule
    Issue 55 Public Health Newsletter of Water Quality Research Australia September 2009 In this Issue: Report On Brisbane Fluoride Incident Report On Brisbane Fluoride Incident 1 An expert report into the fluoride overdosing incident in Brisbane in May this year has highlighted a series Water Problems Hit Alpine Resorts 5 of problems with equipment and monitoring systems, New NDMA Source Identified 6 as well as inadequate training, communication News Items 7 failures and poor management systems that From The Literature 8 collectively contributed to the incident. The report, by the International WaterCentre (IWC) in Brisbane, Web Bonus Articles was commissioned by the Queensland state Arsenic government and reviewed the following aspects of Biofilms the event: • the design and operation including the control Boil Water Notices systems of the fluoridation system at North Pine Cancer Water Treatment Plant; Cryptosporidium • monitoring programs undertaken by various Endemic Disease relevant agencies, including review of data collected; • the communication and notification systems that Norovirus are in place and their effectiveness; Outbreaks • emergency response plans and their effectiveness; Pharmaceuticals • other fluoridation systems in operation in South Rotavirus East Queensland; • national and international experience in Mailing List Details 20 fluoridation systems, particularly any insights in relation to best practice in systems and operations. Editor Martha Sinclair Assistant Editor Pam Hayes As reported in Health Stream Issue 54, the overdosing occurred after fluoride dosing equipment continued to operate during a scheduled maintenance WQRA Internet Address: shutdown of the plant. It was initially believed that a www.wqra.com.au large volume of highly fluoridated water had flowed into the distribution system when the plant was A searchable Archive of Health Stream articles, restarted, possibly exposing up to 4000 households to literature summaries and news items is available elevated fluoride levels (initially reported as over 30 via the WQRA Web page.
    [Show full text]
  • Northern Pipeline Interconnector “Npi” Implementation: the Effect on Operation of the North Pine Wtp
    NORTHERN PIPELINE INTERCONNECTOR “NPI” IMPLEMENTATION: THE EFFECT ON OPERATION OF THE NORTH PINE WTP Paper Presented by: Denis Maguire Author: Denis Maguire, Team Leader, Seqwater North Pine 35th Annual Qld Water Industry Operations Workshop Community Sports Centre, CQ University, Rockhampton 22 to 24 June, 2010 35th Annual Qld Water Industry Operations Workshop Page No. 45 Community Sports Centre, CQ University – Rockhampton, 22 to 24 June, 2010 NORTHERN PIPELINE INTERCONNECTOR “NPI” IMPLEMENTATION: THE EFFECT ON OPERATION OF THE NORTH PINE WTP Denis Maguire, Team Leader, Seqwater North Pine. BACKGROUND The North Pine WTP is a conventional alum coagulation, sedimentation and filtration plant that treats water that supplies many Northern Brisbane suburbs as well as the regions of Moreton Regional Council including Pine Rivers, Caboolture as well as Redcliffe City. The treatment plant is located downstream and adjacent to the North Pine Dam. This treatment plant began in 1970 with operation commencing in 1974. The plant can treat 250 mega litres of water per day. A multi billion dollar Water Grid has been established in SEQ which is an integrated system that secures and efficiently manages SEQ water supplies and comprises an infrastructure network of treatment facilities and two way pipes that move water from new and existing sources across the region. One particular network interface that has been established as part of this Grid initiative is the Northern Pipeline Interconnector (NPI) that links the North Pine WTP with the Lander Shute WTP some 60 klms to the North. 1.0 INTRODUCTION Planning for the Northern Pipeline Interconnector began some years ago.
    [Show full text]