Electrical Symbols and Outlets OBJECTIVES After Studying This Unit, the Student Will Able To

Total Page:16

File Type:pdf, Size:1020Kb

Electrical Symbols and Outlets OBJECTIVES After Studying This Unit, the Student Will Able To Electrical Symbols and Outlets OBJECTIVES After studying this unit, the student will able to . identify and explain the electrical outlet symbols used in the plans of the single-family dwelling. discuss the types of outlets, boxes, fixtures, and switches used in the residence. explain the methods of mounting the various electrical devices used in the residence. understand the meaning of the terms receptacle outlet and lighting outlet. understand the preferred way to position receptacles in wall boxes. position wall boxes in relation to finished wall surfaces. make surface extensions from concealed wiring. determine the number of wires permitted in a given size box. ELECTRICALSYMBOLS In Fig. 2-1 the outletsare shownby the symbols Electrical symbols used on an architectural plan §= and --9-. The standard electrical symbols are show the location and type of electrical device re- shown in Fig. 2-4 to Fig. 2-10 (pages 14-18). quired. A typical electrical installation as taken from a plan is shown in Fig. 2-1. The c.E.c., PartI definesan outletas a point on 53 a wiring system where current is taken to supply /' G ,.. utilization equipment. I A receptacle outlet is an outlet where one or I more receptacles are installed (Fig. 2-2). \1. 53 A lightingoutletis "an outletintendedfor the di- ~_~I rect connection of a lampholder, a lighting fixture, or a pendantcord terminatingin a lampholder"(Fig. 2-3). A toggle switch is not an outlet, however, the term outlet is used broadly by electricians to in- clude noncurrent-consuming switches and similar control devices in a wiring system when estimat- ing the cost of the installation. Each type of outlet Fig.2-1 Use of electrical symbols and notations on a is represented on the plans as a symbol. floor plan. 12 Unit 2 Electrical Symbols and Outlets 13 ALWAYS ALLOW AT LEAST 150 mm (6 in) OF FREECONDUCTOR AT ALL OUTLETS AND JUNCTIONS SO AS TO BE ABLE TO WORK EASILY WITH THE WIRING DEVICESTO BE INSTALLED. Fig. 2-2 When a receptacle is connected to the wires, the outlet is called a receptacleoutlet. For ease in working with wiring devices, the C.E.C, Part I in Rule 12-3002(4) requires that at least 150 mm (6 in) of free conductor be provided. dwelling shows that many different electrical sym- bols are used to represent the electrical devices and equipment used in the building. In drawing electrical plans, most architects, designers, and electrical engineers use symbols approved by the American National Standards Institute (ANSI)whereverpossible.However,plans may contain symbols that are not found in these standards. When such unlisted (nonstandard) sym- bols are used, the electrician must refer to a legend that interprets these symbols. The legend may be included on the plans or in the specifications. In Fig. 2-3 When a lighting fIXtureis connected to the wires, many instances, a notation on the plan will clarify the outlet is called a lighting outlet. The C.E.C, Part I re- the meaning of the symbol. quires that at least 150 mm (6 in) of free conductor be Figs. 2-4 through 2-10 (pages 14-18) list the provided. standard, approved electrical symbols and their meanings. Many of these symbols can be found on The dash lines in Fig. 2-1 run from the outletto the accompanying plans of the residence. Note in the switch or switchesthat controlthe outlet. These these figures that several symbols have the same lines are usually curved so that they cannot be mis- shape. However,differences in the interior presen- taken for invisibleedge lines. Outlets shown on the tation indicate that the meaningsof the symbols are plan without curveddash lines are independentand different. For example, different meanings are have no switch control. shown in Fig. 2-10 (page 18) for the outlet sym- A study of the plans for the single-family bols. A good practice to follow in studying sym- 14 Unit 2 Electrical Symbols and Outlets OUTLETS CEILING WALL INCANDESCENT 0 -Q- a -0 -Q- -a LAMPHOLDER W/PULL SWITCH OPS @ -OPS -<ID RECESSED r-, r-, INCANDESCENT [Q] L_.JI-Q-I @ -tQj -@ SURFACE FLUORESCENT I 0 I -CQ RECESSED FLUORESCENT IOR I --[QR SURFACE OR PENDANT CONTINUOUS ROW [Q FLUORESCENT RECESSED CONTINUOUS ROW IOR FLUORESCENT BARE LAMP FLUORESCENT STRIP SURFACE OR PENDANT EXIT <9 -0 RECESSED CEILING EXIT @ -@ BLANKED OUTLET @ -@ OUTLET CONTROLLED BY LOW-VOLTAGE SWITCHING WHEN RELAY IS INSTALLED (0 --(0 IN OUTLETBOX JUNCTION BOX 0 -0 Fig.2-4 Lighting outlet symbols. Unit 2 Electrical Symbols and Outlets 15 RECEPTACLE OUTLETS -e SINGLE RECEPTACLE OUTLET =@ DUPLEX RECEPTACLE OUTLET =@IG INSULATED (ISOLATED) GROUND RECEPTACLE OUTLET =@ TRIPLEX RECEPTACLE OUTLET ~ DUPLEX RECEPTACLEOUTLET, SPLIT-SWITCHED CIRCUIT =@ DUPLEX RECEPTACLEOUTLET, SPLIT-WIRED CIRCUIT (THREE-WIRE) =@WP WEATHERPROOFRECEPTACLEOUTLET GROUND-FAULT CIRCUIT INTERRUPTER =@GrCI RECEPTACLE OUTLET SPECIAL-PURPOSEOUTLET (SUBSCRIPT LETTERS @cw INDICATE SPECIAL VARIATIONS: DW -DISHWASHER. ALSO a, b, C,d, ETC.ARE LETTERSKEYEDTO EXPLANATION ON DRAWINGS OR IN SPECIFICATIONS). =@R RANGE OUTLET =@c CLOTHES DRYER OUTLET ([) FAN OUTLET @ CLOCK OUTLET 0 FLOOR OUTLET MULTIOUTLET ASSEMBLY; ARROW SHOWS LIMIT OF INSTALLATION. APPROPRIATE SYMBOL INDICATES 1YPE OF OUTLET. SPACING OF OUTLETS INDICATED ~ BY "X"" INCHES. ~ FLOOR SINGLE RECEPTACLE OUTLET ~ FLOOR DUPLEX RECEPTACLE OUTLET ~ FLOOR SPECIAL-PURPOSE OUTLET Fig. 2-5 Receptacle outlet symbols. 16 Unit 2 Electrical Symbols and Outlets CIRCUITING SWITCH OUTLETS 1 2 ........ BRANCH-CIRCUIT HOME RUN TO PANEL S SINGLE-POLE SWITCH THREE WIRES IN CABLE OR RACEWAY S2 DOUBLE-POLE SWITCH IIf S3 THREE-WAY SWITCH -l1li- FOUR WIRES IN CABLE OR RACEWAY, ETC. S4 FOUR-WAY SWITCH DOOR SWITCH SOME DRAWINGSUSE THIS METHOD SD /If OF CONDUCTORIDENTIFICATION: SDS DIMMER SWITCH EQUIPMENTGROUNDINGCONDUCTOR: LONG LINE WITH DOT. SK KEY SWITCH NEUTRALCONDUCTOR:LONG LINE. LOW-VOLTAGE SWITCH PHASE CONDUCTORWITH SWITCH LEGS: SL SHORT LINE. SLM LOW-VOLTAGE MASTER SWITCH WIRING CONCEALEDIN CEILING OR Sp SWITCH WITH PILOT LAMP WALL VARIABLE-SPEED SWITCH sF --- WIRING CONCEALEDIN FLOOR TIME SWITCH ST ----- WIRING EXPOSED SWP WEATHERPROOF SWITCH 0 WIRINGTURNED UP . WIRINGTURNED DOWN Fig. 2-6 Switch outlet symbols. CONDUITONLY (EMPTY) CO bols is to learn the basic forms first and then add --- SWITCH LEG INDICATION.CONNECTS the supplemental information to obtain different OUTLETSWITH CONTROLPOINTS. meamngs. AN ARROWINDICATESA BRANCH-CIRCUIT HOME RUN TO PANEL. THE NUMBER OF ARROWSINDICATESTHE NUMBER FIXTURES AND OUTLETS OF CIRCUITS. IF THERE ARE NO CROSSHATCHES,THEN IT IS Architects often include in the specificationsa cer- ASSUMEDTHAT THE RACEWAYCONTAINSTWO WIRES. tain amount of money for the purchase of electrical fixtures.Theelectricalcontractorincludesthisamount Fig. 2-7 Circuiting symbols. in the bid, and the choice of fixtures is then left to the homeowner.If the owner selects fixtures whose total costexceedsthe fixtureallowance,the owneris ufactured wiring systems where the "box" is an in- tegral part of the system. For standard wiring meth- expected to pay the difference between the actual cost ods, such as cable or conduit, a box is usually andthe specificationallowance.If the fixturesare not required. selectedbeforethe roughing-instageof wiringof the Outlet boxes must be accessible, Rule house, the electrician usually installs outlet boxes 12-3016(1). having standardfixturemountingstuds. Be careful when roughing in boxes for fixtures Most modern surface-mount lighting fixtures and also when hanging ceiling fixtures to: can be fastened to an octagon box (Fig. 2-11 (page 19), top row) or an outlet box with a plaster ring . nonmetallic device (switch) boxes. using appropriate No. 8-32 metal screws and . nonmetallic device (switch) plaster rings. mountingstrapfurnishedwith the fixture(Fig.2-11, metallic device (switch) boxes. third row). A box must be installed at each outlet or switch . metallic device (switch) plaster rings. location,Rule 12-3002(1). There are exceptions to . any nonmetallic box, unless specifically this rule, but in general they relate to special man- marked on the box or carton for use as a fixture Unit 2 Electrical Symbols and Outlets 17 G PUSH BUTTON 111111- BATTERY D' BUZZER -1111 GROUND [J!) BELL 0 JUNCTION BOX - CEILING JUNCTION BOX - WALL \[]!) COMBINATION BELL/BUZZER -0 ~ EJ CHIME - - CIRCUIT BREAKER OVERCURRENT DEVICE (FUSE, 0- ANNUNCIATlOR ~ BREAKER, THERMAL OVERLOAD) 0 ELECTRIC DOOR OPENER - '-(D}- SWITCH AND FUSE 0 MAID'S SIGNAL PLUG OR SWITCH AND FUSE I<J TELEPHONE (PRIVATE SYSTEM) -~ ~ TELEPHONE (OUTSIDE LINE) THERMOSTAT <D CEILING PADDLE FAN [2] TRANSFORMER X ~ TELEVISION OUTLET - LIGHTING PANEL CEILING PADDLE FAN W/LlGHT r1J'JZi.IPOWER PANEL w. HEATING PANEL X Fig. 2-8 Miscellaneous symbols. support, or to support other equipment, or to framing, recessing, or mounting requirements for accommodateheat-producingequipment. the fixtures. This information must be provided in the case of recessed fixtures, which require a spe- Therefore,unless the box, deviceplasterring, or cific wall or ceiling opening. carton is markedto indicatethat it has been listedby Many types of lighting fixtures are presently CSA for the support of fixtures, do not use where available.Fig. 2-11 (page 19)shows severaltypical fixtures are to be hung. Refer to Fig. 2-12 (page lighting fixtures that may be found in a dwelling 20) and Rule 12-1110. unit. Also shown are the electrical symbols used Be careful when installing a ceiling outlet box on plans to designate these fixtures and the type of for the purpose of supporting a fan. See Unit 9 for outlet boxes or switch boxes on which the lighting detailed discussion of paddle fans and their instal- fixturescan be mounted. A standard receptacleout- lation. let is shown as well. The switch boxes shown with If the owner selects fixtures prior to construc- it are made of steel.Switchboxes may also be made tion, the architect can specify these fixtures in the of plastic, as shown in Fig. 2-12 (page 20). Other plans and/or specifications.
Recommended publications
  • 2020 National Electrical Code® Style Manual
    2020 NATIONAL ELECTRICAL CODE® STYLE MANUAL 1 FOREWORD August 2020 The National Electrical Code® is used nationally and internationally as the basis for safeguarding persons, buildings, and their contents from hazards arising from the use of electricity. It is vitally important that the text be as explicit as possible, and that maximum consistency be achieved in the language used in the text. The Code contains those provisions considered necessary for safety and thus is widely used as a basis for legal enforcement in the installation of electrical conductors and equipment in buildings and certain other premises (as detailed in the Code itself); this places a major responsibility on those involved in the preparation of document text to use forms of expression that promote uniform interpretation. The National Electrical Code Correlating Committee has recognized these responsibilities and has issued this manual. Preparation and Date of Adoption. This manual was originally prepared by the Editorial Task Group of the National Electrical Code Committee and adopted by the National Electrical Code Correlating Committee on May 13, 1969. It was amended September 22, 1975, October 11, 1984, October 12, 1989, and May 9, 1994. In January 1999, the Correlating Committee Task Group on the Usability of the NEC rewrote the manual. It was adopted by the National Electrical Code Correlating Committee on March 19, 1999 and by the Standards Council on April 15, 1999. It was amended March 1, 2001, January 15, 2003, and August 9, 2011, August 2015, and December 2020. 2 TABLE OF CONTENTS Foreword ........................................................................................................ 2 Chapter 1 General 4 1.1 Purpose ............................................................................................
    [Show full text]
  • W-Series Junction Boxes
    208-209.qxp 7/22/2010 2:58 PM Page 209 W-Series Junction Boxes Application and Selection Applications: Considerations for Options and Accessories: Junction boxes, designed for hazardous Selection: A wide variety of options and accessories and non-hazardous locations, are used in a • Environmental location – the physical for special application are available for the variety of industries to perform the location of the junction box will call for various junction box families. These can following functions: proper construction of the box to meet be selected once the type of junction box has been determined. These options are W-Series • As a pull box National Electrical Code requirements and will affect the material and finish shown on the individual pages. Some of Boxes • To provide enclosures for splices and needed to meet weather and corrosive the options available include: taps conditions, if present. • Special covers • As a mounting box for multi-device • Number and size of conductors – • Hinged covers control stations combined with the function to be performed (i.e., splicing, pull box), • Materials and finishes • For housing apparatus, instruments, and determines the amount of space other devices needed, and therefore, the required • Equipment mounting plates physical dimensions of the box. • Conduit or device openings • Conduit layout – determines the number, • Corro-free™ epoxy powder coat – size, and location of the conduit information available on request openings in the box. It will also determine the type of mounting required (i.e., flush or surface positioning of the box). • Flexibility required – if changes in the electrical system are anticipated, the box chosen should be easily adaptable, either by construction or size to the future system.
    [Show full text]
  • Guidance Notes on Recommended Specifications of Junction Box and Cable Tray for Offshore Application
    Guidance Notes on Recommended Specifications of Junction Box and Cable Tray for Offshore Application GUIDANCE NOTES ON RECOMMENDED SPECIFICATIONS OF JUNCTION BOX AND CABLE TRAY FOR OFFSHORE APPLICATION FEBRUARY 2018 American Bureau of Shipping Incorporated by Act of Legislature of the State of New York 1862 2018 American Bureau of Shipping. All rights reserved. ABS Plaza 16855 Northchase Drive Houston, TX 77060 USA Foreword Foreword These Guidance Notes provide ABS recommendations for the design and construction of cable trays and junction boxes. These Guidance Notes are applicable to fixed and floating offshore structures as well as drilling units. These Guidance Notes provide recommendations and best practices for standard specifications of certain electrical and instrumentation components thus improving cost efficiency (i.e., design man-hours, operation and maintenance costs), and increasing predictability of operation without compromising quality and safety in offshore structures and units. The recommendations in these Guidance Notes are based on industrial experiences, project experience, shipyard practices, manufacturer’s data sheets, national regulations, international standards, and ABS Rules. These Guidance Notes become effective on the first day of the month of publication. Users are advised to check periodically on the ABS website www.eagle.org to verify that this version of these Guidance Notes is the most current. We welcome your feedback. Comments or suggestions can be sent electronically by email to [email protected]. Terms of Use The information presented herein is intended solely to assist the reader in the methodologies and/or techniques discussed. These Guidance Notes do not and cannot replace the analysis and/or advice of a qualified professional.
    [Show full text]
  • Solar PV and the Electrical Code
    PV and the Electrical Code Page 1 PV and the Electrical Code Canadian Solar Industries Association (CanSIA) PV and the Electrical Code Page 2 This course was prepared by the Canadian Solar Industries Association (CanSIA) 2378 Holly Lane, Suite 208 Ottawa, Ontario K1V 7P1 Tel: (613) 736-9077 FAX: (613) 736-8938 Email: [email protected] www.cansia.ca Authors: Charles R. Price Eric Smiley with funding assistance provided by Natural Resources Canada Renewable and Electrical Energy Division Ó Canadian Solar Industries Association 2004 Version 1.2 Notice to the Reader Publisher and authors do not warrant or guarantee any of the products described herein or perform any independent analysis in connection with any of the product information contained herein. Publisher and authors do not assume and expressly disclaims any obligation to obtain and include information other than that provided to it by the manufacturer. The reader is expressly warned to co nsider and adopt all safety precautions that might be indicated by the activities described herein and to avoid all potential hazards. By following the instructions contained herein, the reader willingly assumes all risks in connection with such instruction. The publisher and authors maks no representation or warranties of any kind, including but not limited to, the warranties of fitness for particular purposes or merchantability, nor are any such representations implied with respect to the material set forth herein, and the publisher and authors take no responsibility with respect to such material. The publisher and authors shall not be liable for any special, consequential or exemplary damages resulting, in whole or in part, from the readers’ use of, or reliance upon this material.
    [Show full text]
  • Electrical Inspection Checklist for One-Family Homes Based on the 2020 National Electrical Code® (NEC®)
    Electrical Inspection Checklist for One-Family Homes Based on the 2020 National Electrical Code® (NEC®) NOTE: The Board of Electricity adopted the 2020 National Electrical Code (NEC) with an effective date of Nov. 17, 2020. Accordingly, the Department of Labor and Industry began enforcing the 2020 NEC on Nov.17, 2020. Electrical work authorized by permits issued on or after this date must comply with the 2020 NEC. Electrical license examinations are based on the requirements of the 2020 NEC beginning Jan. 1, 2021. However, due to concerns regarding the availability of 2-pole GFCI circuit breakers, the department delayed enforcement of the requirements for 250-volt GFCI receptacles and outlet requirements found in NEC 210.8(A) and 210.8(F). On April 5, 2021, DLI will begin enforcing the 250-volt GFCI receptacle and outlet requirements found in NEC 210.8(A) and 210.8(F). Industry circuit breaker manufacturers have confirmed that supply-chain challenges will be resolved in March 2021. Electrical work authorized by permits issued on or after April 5, 2021, must comply with the 2020 NEC. 001 An owner (i.e. homeowner) who files a Request for Electrical Inspection form (i.e. permit) with the Department of Labor and Industry or other electrical inspection authority is signing an affidavit and declaring they own and occupy the residence and they will personally perform all of the electrical work, including the planning and laying out of the electrical work. 002 The term “owner” is defined in law as a natural person who physically performs electrical work on premises the person owns and actually occupies as a residence or owns and will occupy as a residence upon completion of construction.
    [Show full text]
  • Electrical Code Amendment
    CITY OF GRAPEVINE Chapter 7, Buildings and Construction, Article III, Electrical Code ARTICLE III. ELECTRICAL CODE DIVISION 1. GENERALLY Sec. 7-30. Definitions. For the purposes of this article, hereinafter referred to as the electrical code or this code, the following terms, phrases, words, and their derivatives shall be construed as set out in this section: Approved: Acceptable to the building inspection division and/or the electrical board of appeals of the city. Authorized person: Any person, as defined in section 1-5, registered or licensed under the provisions of this code to do work as permitted under the specific provisions of this code. Buildings, building use: Words relating to buildings and building use, when not otherwise separately defined, shall have meanings which conform to the meanings set out in the zoning ordinance of the city; otherwise, they shall have their usual dictionary meanings. City: The territory within the corporate limits of the city, or the legally constituted governing body thereof, its agents and its officers. Conductor: A wire or cable or other form of metal suitable for carrying electric current or potential. Electrical apprentice: Any person who has been issued a license from the State of Texas as an electrical apprentice as provided for by state law. Electrical construction: All work and materials used in installing, maintaining, or extending a system of electrical wiring and all appurtenances, apparatus or equipment used in connection therewith, inside or outside of or attached to any building, structure, lot or premises. Electrical contractor: Any person who has been issued a license from the State of Texas as an electrical contractor as provided for by state law.
    [Show full text]
  • Answer the Purpose: 4
    Page 26 1. CONDUCTORS Conductors are defined as materials that easily allow the flow of _________. Metals are _______ conductors while insulators are ______ . The 2 common metals used for conductors in the electrical trade are: ___________ and ______________. Aluminium has become more prevalent for larger C.S.A. conductors as it is cheaper and lighter but more brittle than copper. Current/ Copper/ Aluminium Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. In mainland Europe, a round equivalent is more common. Flat cables (or festoon cables) are made in PVC and Neoprene and are used as trailing cables for cranes, open filed conveyors and shelve service devices. Flat cables offer the advantages of extremely small bending radius’s, high flexibility and minimum wastage of space. Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth.
    [Show full text]
  • Industrial MI Wiring Cable
    Industrial MI Wiring Cable Installation Manual for Alloy 825 Sheath Cable Wiring Systems Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD. nVent PYROTENAX mineral insulated (MI) industrial wiring cables must be installed in accordance with the requirements of national and local codes and standards, the installation instructions in this manual, and the customer’s specification. Read these important safeguards and carefully follow the installation instructions. • Ensure the cable has been stored properly and is in good condition prior to commencing installation. • Always use safe working practices when installing cables, observing OSHA and other national safety rules. • Store cables indoors in a clean, dry, covered area, if possible. • During the time that the cables are exposed and during cable pulling activities, protect cables from nearby or overhead work to prevent damage to the cable sheath. • Do not pull cables around corners that have sharp edges, such as corners in cable trays, or other obstructions. • Prevent damage to cables by removing any abrasions or sharp edges from surface of support system. • Damage to cables or components can cause sustained electrical arcing or fire. Do not energize cables that have been damaged. Damaged cable or terminations may need to be repaired or replaced. Damaged cable should be repaired by a qualified person. • When installing cables which may be exposed to hydrocarbon flash fires, use only steel or stainless steel in the support system. ii | nVent.com Table of Contents General Information
    [Show full text]
  • Don't Be Confused by Your Fuse
    Head Office Neptronic® 400 Lebeau Blvd. HVAC Controls Electric Actuators Actuated Valves Montreal, Quebec, Canada H4N 1R6 Tel.: (514) 333-1433 Humidifiers Electric Heaters Fax: (514) 333-3163 Toll Free: 1-800-361-2308 Don’t be confused by your fuse: MCA and MOP for your humidifier explained Before we start, we need first to understand what MCA and MOP are. The minimum circuit ampacity (MCA) and maximum overcurrent protection (MOP) ratings provide a guide for safely connecting field-wired equipment to the building mains. Understanding these ratings, and their relationship to each other, is critical to properly selecting wire and circuit breaker sizes. What is MCA? Minimum Circuit Ampacity (MCA) is a calculated value that specifies the minimum main power wire size. It is also used to determine the minimum wire size required for a field wired product. This specification is necessary in order to guarantee that the wiring will not overheat under expected operating conditions. The wire size takes into account the normal current draw, aging of components and anticipated faults. More specifically, the MCA is the highest steady-state electrical current that the unit should see when operating correctly. What is MOP? Maximum Over-Current Protection (MOP) is a calculated value that determines the maximum size of the over-current protection device (fuse or breaker). There are different MOP equations depending on your application. The maximum overcurrent protection (MOP) is the maximum circuit breaker size required to properly protect the equipment under anticipated fault conditions. The MOP takes into account startup surges and component aging. Supply wiring must be rated to carry the amps shown as MCA.
    [Show full text]
  • Installation
    S&C Circuit-Switchers — Mark VI Installed on S&C Mounting Pedestals—84- through 102-inch Phase Spacing Outdoor Transmission (69 kV through 138 kV) Installation Table of Contents Section Page Section Page Introduction Wiring and Adjusting the Switch Operator Qualified Persons . 2 Before Starting . 31 Read this Instruction Sheet . 2 Connecting Control Power and Retain this Instruction Sheet . 2 User-Furnished Control Circuits . 32 Proper Application . 2 Using the Manual Operating Handle . 34 Warranty . 2 Using the Decoupling Selector Handle . 35 Adjusting the Switch Operator . 37 Safety Information Understanding Safety-Alert Messages . 3 Terminal Pads and Conductor Connections Following Safety Instructions . 3 Installing the Terminal Pad . 49 Replacement Instructions and Labels . 3 Circuit-Switcher Start-Up and Check-Out Location of Safety Labels . 4 Start-Up . 51 Safety Precautions . 5 Check-Out . 54 Inspection and Packing Indicators Inspection . 6 Understanding the Interrupter Indicators . 55 Packing . 6 Understanding the Gas-Pressure Gauge . 56 Storage . 6 Understanding the Optional Remote Gas-Density Indicator . 58 Installation Before Starting . 7 Installing the Mounting Pedestals and Support Structure . 8 Installing the Gearbox . 11 Installing the Disconnect Pole-Units . 12 Installing the Interrupters . 13 Checking Operation of Disconnect . 18 Installing the Drive Train . 20 Installing the Mark VI CS-1A Switch Operator . 22 Installing the Interrupter Charging Motors . 25 Installing the Conduit Assembly . 27 Wiring the Interrupters and Charging Motors . 28 June 11, 2012© S&C Electric Company Instruction Sheet 712-503 Introduction Qualified Persons Ç WARNING The equipment covered by this publication must be installed, operated, and main- tained by qualified persons who are knowledgeable in the installation, operation, and maintenance of overhead electric power transmission and distribution equip- ment along with associated hazards.
    [Show full text]
  • 2018 Canadian Electrical Code Saskatchewan Interpretations
    120 Based on the 2018 Canadian Electrical Code Effective: January 1, 2019 V4.2 (this page left intentionally blank) ELECTRICAL INSPECTIONS Preface and Scope The Canadian Electrical Code, Part l, Twenty-Fourth Edition, as interpreted by these requirements, issued under Section 5 of The Electrical Inspection Act, 1993, shall govern the workmanship and all other matters pertaining to electrical equipment and the installation of electrical equipment in or upon any land, buildings, structures, and premises. All previously issued bulletins are superseded by these interpretations. This document contains supplementary information to clarify the requirements of the 24th edition of the Canadian Electrical Code (CEC), and by their inclusion herein is adopted as requirements under Section 5 of The Electrical Inspection Act, 1993. Report of Accident The Electrical Inspection Act, 1993 c.E-6.3 s.27 requires: “Where an accident involving an electrical installation or electrical equipment occurs and results in a death or injury of a person or in a fire or an explosion, the contractor or the contractor’s agent or the owner of the electrical equipment or the owner’s agent shall immediately notify the Chief Electrical Inspector, stating the precise location of the accident, its general nature and results”. Investigation of Accident The Electrical Inspection Act, 1993 c.E-6.3 s.28 requires: The accident site is to be preserved, “no part of any electrical plant or electrical equipment involved is to be removed or its position altered by any person”, “until the written permission of an Inspector has been obtained”. 2018 Saskatchewan Interpretations Page 1 ELECTRICAL INSPECTIONS Table of Contents PREFACE AND SCOPE ..................................................................................................................................................
    [Show full text]
  • Appendix 'C' Division 26 – Electrical Requirements
    The City of Winnipeg Bid Opportunity No. 496-2013 Template Version: C420130321 - RW APPENDIX ‘C’ DIVISION 26 – ELECTRICAL REQUIREMENTS The City of Winnipeg List of Contents Section 00 01 11 Bid Opportunity No. 496-2013 Page 1 Section Title Pages 260005 Electrical Scope of Work 1 260500 Common Work Results - For Electrical 7 260520 Wire and Box Connectors 0-1000 V 2 260521 Wires and Cables 0-1000 V 1 260522 Connectors and Terminations 2 260528 Grounding – Secondary 3 260529 Hangers and Supports for Electrical Systems 2 260531 Splitters, Junction, Pull Boxes and Cabinets 1 260532 Outlet Boxes, Conduit Boxes and Fittings 2 260534 Conduits, Conduit Fastenings and Conduit Fittings 3 260544 Installation of Cables in Trenches and in Ducts 3 262402 Service Entrance Board 3 262417 Panelboards Breaker Type 3 262726 Wiring Devices 3 262821 Moulded Case Circuit Breakers 2 265000 Lighting 2 The City of Winnipeg Section 26 00 05 Bid Opportunity No. 496-2013 SCOPE OF WORK Page 1 Part 1 General 1.1 GENERAL .1 Include in electrical section, provision of labour, new materials, tools, transportation, services and facilities for a complete electrical installation. The installation shall be left complete in all respects and ready for operation. Installation shall be deemed incomplete and final payment shall not be released until the electrical installation is completed to the complete satisfaction of the responsible Contract Administrator. .2 The electrical scope of work includes, but is not necessarily limited to the following provisions: .1 Provision of electrical distribution including CSTE, customer service termination enclosure, buried cabling and cabling in conduit for a 120/240 volt electrical distribution system consisting of a 200 Amp, 120/240 Volt circuit breaker panel c/w 100 Amp 120/240V sub distribution for Fly-over Girder utility power, and provision for an additional power sub distribution.
    [Show full text]