Voltage-Clamp and Patch-Clamp Techniques Hans Reiner Polder, Martin Weskamp, Klaus Linz, Rainer Meyer

Total Page:16

File Type:pdf, Size:1020Kb

Voltage-Clamp and Patch-Clamp Techniques Hans Reiner Polder, Martin Weskamp, Klaus Linz, Rainer Meyer 3.4 272 Voltage-Clamp and Patch-Clamp Techniques Hans Reiner Polder, Martin Weskamp, Klaus Linz, Rainer Meyer Introduction History of Membrane Potential and Current Recordings in Cardiac Tissue This chapter describes various methods of analysis of the electrical behaviour of ex- citable cells using microelectrodes. Since their introduction in the 1920’s, microelec- trodes have become the “workhorses” of electrophysiology, and a comprehensive number of publications exist about this topic. Here, we give a consolidated overview of the most important methods of investigation at single cell level, however, high throughput methods and automated recording procedures are not discussed. There is a reference list (Further Reading) at the end of this chapter, detailing some of the most important books published in recent decades. Since the nineteenth century, it has been well known that excitable cells are able to produce electrical signals. However, until the invention of the first glass microelec- trodes, by Ling and Gerard in 1949, the origin of these electrical signals could not be proven. For the first time, these glass micropipettes allowed the detection of the mem- brane potential of a cell, as their tips were small enough to penetrate the cell mem- brane without destroying the cells, and their high electrical resistance avoided shunting the membrane potential (see chapter Principles of Electrodes). These micro- electrodes were connected to the high resistance input of a voltage amplifier. The monitoring of the membrane potential, delivered the base of our actual understand- ing of electrical events inside the heart. In 1951, the first experiments on mammalian heart muscle tissue using these elec- trodes were published (Draper and Weidmann 1951). During their experiments, the negative membrane potential of around –80 mV and the cardiac action potential (AP), in its typical shape and with its real amplitude, could be recorded. Application of the voltage clamp technique (Cole 1949; Hodgkin et al. 1952), adapted to cardiac tissue (Deck et al. 1964), revealed the different current components of the cardiac action potential, which are described in chapter Membrane Currents During the Ac- tion Potential. A further leap in progress for cardiac physiology was gained by the de- velopment of techniques to isolate single living cardiac myocytes in the late 1970’s (Dow et al. 1981). At the same time, the patch clamp technique was invented (Hamill et al. 1981). Some small changes in the geometry of the electrodes, as well as the de- Voltage Clamp and Patch Clamp Techniques 273 3.4 velopment of new amplifiers (patch and single electrode clamp amplifiers), opened a completely new field as the recording of current through single channels became pos- sible. In addition, monitoring of membrane potential, as well as currents, was highly simplified. This allowed the description of new membrane currents and detailed analysis of their molecular basis, a process that still continues today. Description of Methods and Practical Approach Membrane Currents During the Action Potential The basic ionic currents during the AP were discovered by means of voltage clamp experiments on multicellular cardiac tissue preparations. Depolarisation, is caused by a voltage dependent sodium inward current, INa. Depolarisation, in turn, leads to a drop in K+ conductance, and the opening of voltage gated Ca2+ channels giving rise to an inward-calcium current, ICa. ICa lasts for less than twenty up to two hundred milli- seconds, depending on the species and thus AP- duration, e.g. murine AP-duration is around 40 ms (own unpublished observations) whereas the guinea-pig AP lasts for about 400 ms (Linz and Meyer, 1998a). The interplay of low K+ conductance and ICa keeps the membrane potential depolarised, and thus forms the plateau of the car- diac AP. During the plateau phase, the K+ conductance gradually re-increases, the ICa finally inactivates, and outward potassium currents repolarise the membrane. A detailed overview of cardiac excitation contraction coupling is presented in Bers (2002). As mentioned above, isolation of living cells and the invention of the patch clamp technique simplified experiments on cardiac myocytes, thus our knowledge of cellu- lar electrical events in the heart has blown up in the last twenty years. Therefore, some more details have to be added to the concept mentioned above. The role of the 2+ depolarising INa remains unchanged. As a family of Ca currents in many different cells has been discovered, it has become clear that the most important current in car- diac myocytes is the L-type current, ICa,L (see chapter 3.5). In addition, a so-called high voltage activated Ca2+ current, the T-type current, is expressed in cardiac myocytes. The concept of K+ currents has become relatively complicated in recent years. Differ- ences in AP shape between species and cardiac tissues like pacemaker cells, cells of conductive tissue, atrial and ventricular myocytes, depend mainly on the expression of different types of K+ channels. As the diversity of K+ currents is not the topic of this report, only a few aspects will be mentioned here (for a more detailed review see chapter 3.5). In many species a transient outward current Ito is activated very rapidly. This current induces an initial repolarisation after the peak of the AP. The ampli- tude of Ito determines the potential at which the plateau starts, and thereby Ito also determines duration and shape of the AP. The final repolarisation is brought about + by two slowly activating K current components, IKr and IKs. At potentials negative + of –50 mV, IK1 becomes the dominating K current, determining the resting po- tential. 3 274 Electrophysiological Techniques Principles of Electrodes Since the invention of glass microelectrodes, different forms have been developed, however, all follow the same principles as described in this chapter. “Microelectrodes” are micropipettes made of glass, filled with electrolytic solutions, with an electric connection to the recording amplifier. The microelectrode is in direct contact with the cell interior, either by penetration of the cell membrane (“sharp microelectrode re- cordings”), or by rupturing the membrane inside a suction electrode sealed to the sur- face of the cell (whole cell patch configuration). In case of a “perforated patch”, some pore forming agents are used in the pipette solution to give access to the cell interior (see chapter Perforated Patch). Microelectrodes consist of the stem, the shoulder, the taper and the tip (Fig. 1). The stem with the constant diameter is the longest part of the microelectrode, followed by the shoulder and then the taper that has a continu- ously decreasing diameter. The taper ends in a fine tip. Depending on the diameter of the tip, microelectrodes are termed “sharp” (0.5 µm or less) or “patch” electrodes (typically 1 to 3 µm, fire polished). Microelectrodes are filled with electrolyte solution (see below). Normally, an Ag-AgCl wire is immersed into the electrolyte, connecting the electrode to the recording amplifier. Thus, the microelectrode converts ionic cur- rent in solution, into an electron current in wires, according to the following revers- ible reaction: Cl– + Ag AgCl + e– In-Vitro Techniques Figure 1a–d Microelectrode. a, b Scanning electron micro- scopic images of the tip of a sharp microelec- trode. Scale a: 10 µm; Scale b: 1 µm. c, d Light microscopic images of a patch clamp electrode. c Displays in low magnification the taper and the tip, scale 500 µm. d Tip of same electrode in higher magnification, scale 10 µm. Filled with 135 K+, Na+, 135 Cl– 10 HEPES, 0.5 EGTA, all in mM, the electrode had a resistance of 4 MΩ Voltage Clamp and Patch Clamp Techniques 275 3.4 Figure 2 Equivalent circuit microelec- trode (ME). Terminology and equivalent circuit of a micro- electrode. CEL electrode capacity, REL electrode resistance, TP tip potential Chloriding of silver wires can easily be done by electrolysis. Many available microelec- trode holders have built-in Ag-AgCl pellets, which are a good but more expensive al- ternative to chlorided silver wires. In terms of electrochemistry, only this part is an “electrode”. In electrophysiology, the terms “microelectrode”, “patch” or “suction elec- trode”, are used for the glass micropipette and the electrochemical electrode. In most cases, the reference (“ground signal”) for the measurement is the bath surrounding the cell. The electrical connection is also made via chlorided silver wire or an Ag-AgCl pellet. This reduces a part of the occurring offset potentials. Offset potential compensation is a very important procedure, and can be done prior to an experiment if all offsets are constant. In case of solution changes, offset potentials will also change and therefore correction procedures may be necessary (Neher 1995). Electrical Properties From an electrical point of view, microelectrodes are RC-elements (Fig. 2) with a bat- tery. The resistance (R), capacitance (C), and electrode potential are mostly non-lin- ear and spread along the thin part of the microelectrode. The most unpleasant non-linearity is often called “rectification”, this is because the microelectrode resis- tance varies depending on the direction of current flow. Beside mechanical sensitiv- ity, these factors are serious limitations, which require sophisticated recording electronics. A simplified equivalent circuit diagram shows a resistor in parallel to a capacitor and in series to a source of voltage, the tip potential. Microelectrodes are selected carefully to have linear electrical properties in the range of operation. There- fore, the non-linear electrical properties (rectification of electrodes) are usually of minor practical importance and are omitted. The microelectrode resistance Rel is basically dependent on the glass species, the diameter and length of the tip, the concentration of the electrolyte inside the micro- electrode, and the concentration of the solution into which the microelectrode is im- mersed. The lower the concentration of the filling solution and the finer the diameter 3 276 Electrophysiological Techniques of the tip, generally, the higher the microelectrode resistance.
Recommended publications
  • A Comparison of the Performance and Application Differences Between Manual and Automated Patch-Clamp Techniques
    Send Orders of Reprints at [email protected] Current Chemical Genomics, 2012, 6, 87-92 87 Open Access A Comparison of the Performance and Application Differences Between Manual and Automated Patch-Clamp Techniques Xiao Yajuan, Liang Xin and Li Zhiyuan* Key Laboratory of Regenerative Biology, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China Abstract: The patch clamp technique is commonly used in electrophysiological experiments and offers direct insight into ion channel properties through the characterization of ion channel activity. This technique can be used to elucidate the in- teraction between a drug and a specific ion channel at different conformational states to understand the ion channel modu- lators’ mechanisms. The patch clamp technique is regarded as a gold standard for ion channel research; however, it suffers from low throughput and high personnel costs. In the last decade, the development of several automated electrophysiology platforms has greatly increased the screen throughput of whole cell electrophysiological recordings. New advancements in the automated patch clamp systems have aimed to provide high data quality, high content, and high throughput. However, due to the limitations noted above, automated patch clamp systems are not capable of replacing manual patch clamp sys- tems in ion channel research. While automated patch clamp systems are useful for screening large amounts of compounds in cell lines that stably express high levels of ion channels, the manual patch clamp technique is still necessary for study- ing ion channel properties in some research areas and for specific cell types, including primary cells that have mixed cell types and differentiated cells that derive from induced pluripotent stem cells (iPSCs) or embryonic stem cells (ESCs).
    [Show full text]
  • Patch-Clamp Study of Y-Aminobutyric Acid Receptor C1
    Proc. Natl. Acad. Sci. USA Vol. 85, pp. 9336-9340, December 1988 Neurobiology Patch-clamp study of y-aminobutyric acid receptor C1- channels in cultured astrocytes (glia/benzodiazepine/ion channel) JOACHIM BORMANN*t AND HELMUT KETTENMANNt *Max-Planck-Institut fur biophysikalische Chemie, Am Fassberg, D-3400 Gottingen, Federal Republic of Germany; and tInstitut fPir Neurobiologie, Universitat Heidelberg, Im Neuenheimer Feld 504, D-6900 Heidelberg, Federal Republic of Germany Communicated by Gerald D. Fischbach, August 22, 1988 ABSTRACT The membrane channels operated by y- receptors, did not induce any reaction in the astrocytes; aminobutyric acid (GABA) were studied in cultured astrocytes GABAA receptor antagonists, such as bicuculline and picro- from rat cerebral hemispheres by using patch-clamp tech- toxin, blocked the effect of GABA (12). Benzodiazepine niques. The channel properties appeared to be very similar, in receptor agonists and antagonists showed up further similar- many respects, to those present in neuronal cell membranes. ities to neurons, whereas the action of inverse agonists The Cl-selective channels were activated after the sequential revealed differences between neurons and glial cells (14). binding of two GABA molecules to the receptor, as deduced In the present study, we have obtained direct evidence for from the slope of the dose-response curve. Single-channel the existence of GABA-activated channels in glial cells. By currents displayed multiple conductance states of 12 pS, 21 pS, using patch-clamp techniques, we have compared the prop- 29 pS, and 43 pS, with the main-state conductance being 29 pS. erties of GABA receptor channels in cultured astrocytes to The gating properties could be described by a sequential those described for neurons.
    [Show full text]
  • An Improved Voltage Clamp Circuit Suitable for Accurate Measurement of the Conduction Loss of Power Electronic Devices
    sensors Article An Improved Voltage Clamp Circuit Suitable for Accurate Measurement of the Conduction Loss of Power Electronic Devices Qiuping Yu, Zhibin Zhao *, Peng Sun, Bin Zhao and Yumeng Cai State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China; [email protected] (Q.Y.); [email protected] (P.S.); [email protected] (B.Z.); [email protected] (Y.C.) * Correspondence: [email protected] Abstract: Power electronic devices are essential components of high-capacity industrial converters. Accurate assessment of their power loss, including switching loss and conduction loss, is essential to improving electrothermal stability. To accurately calculate the conduction loss, a drain–source voltage clamp circuit is required to measure the on-state voltage. In this paper, the conventional drain–source voltage clamp circuit based on a transistor is comprehensively investigated by theoretical analysis, simulations, and experiments. It is demonstrated that the anti-parallel diodes and the gate-shunt capacitance of the conventional drain–source voltage clamp circuit have adverse impacts on the accuracy and security of the conduction loss measurement. Based on the above analysis, an improved drain–source voltage clamp circuit, derived from the conventional drain–source voltage clamp circuit, is proposed to solve the above problems. The operational advantages, physical structure, and design guidelines of the improved circuit are fully presented. In addition, to evaluate the influence of component parameters on circuit performance, this article comprehensively extracts three electrical Citation: Yu, Q.; Zhao, Z.; Sun, P.; quantities as judgment indicators. Based on the working mechanism of the improved circuit and Zhao, B.; Cai, Y.
    [Show full text]
  • Lecture 1: an Introduction to Plasticity and Cellular Electrophysiology
    Lecture 1: An Introduction To Plasticity and Cellular Electrophysiology MCP 2003 Charge separation across a ATPase + semipermeable Ca++ 3Na ATPase membrane is the 2K+ (mM) basis of excitability. K+ = 140 + Na = 7 ++ + Ca Cl- = 7 3Na (mM) Ca++ = 1 x 10-4 co-transporter K+ =3 Na+ = 140 membrane pores Cl- = 140 with variable Ca++ = 1.5 permeability - + R - + m Cm gK+ gCl- gNa++ Convention: Current direction is defined by the direction of increasing positive charge. Na++ flux into a cell is an inward current. K+ flux out of a cell is an outward current. Cl- flux into a cell is an outward current. A depolarizing current is a net influx of + ions or a net efflux of negative ions. A hyperpolarizing current is a net efflux of + ions or a net influx of negative ions. I Outward rectification: when a membrane allows outward current (net + charge out) V to flow more easily than and inward current. Outward rectification I Inward rectification: when a membrane allows inward current to flow more easily V than an outward current. Inward rectification Methods of Measuring Function In Excitable Membranes Field potentials: measure current sources _ low pass filter and sinks from populations of neurons + across the electrode resistance. _ 0 Brain mV-V - t (sec) + Microelectrode extracellular recording: measures action potentials from a small _ number of neurons. 0 mV pulse amplitude window - Intracellular recording: can measure voltage, t (msec) band pass filter 1KHz-10KHz +40 0 Voltage clamp recording: resting membrane Can pass current to compensate -60 potential for voltage change. In this way voltage is held ~ constant and current applied to _ compensate is a measure of the current flowing.
    [Show full text]
  • Patch Clamping: an Introductory Guide to Patch Clamp
    Patch Clamping An Introductory Guide to Patch Clamp Electrophysiology Areles Molleman University of Hertfordshire, UK Patch Clamping Patch Clamping An Introductory Guide to Patch Clamp Electrophysiology Areles Molleman University of Hertfordshire, UK Copyright© 2003JohnWiley&SonsLtd,TheAtrium,SouthernGate,Chichester,WestSussex PO19 8SQ, England Telephone (+44) 1243 779777 Email (for orders and customer service enquiries): [email protected] Visit our Home Page on www.wileyeurope.com or www.wiley.com All Rights Reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, scanning or otherwise, except under the terms of the Copyright, Designs and Patents Act 1988 or under the terms of a licence issued by the Copyright Licensing Agency Ltd, 90 Tottenham Court Road, London W1T 4LP, UK, without the permission in writing of the Publisher. Requests to the Publisher should be addressed to the Permissions Department, John Wiley & Sons Ltd, The Atrium, Southern Gate, Chichester, West Sussex PO19 8SQ, England, or emailed or [email protected], or faxed to (+44) 1243 770571. This publication is designed to provide accurate and authoritative information in regard to the subject matter covered. It is sold on the understanding that the Publisher is not engaged in rendering professional services. If professional advice or other expert assistance is required, the services of a competent professional should be sought. OtherWileyEditorialOffices John Wiley & Sons Inc., 111 River Street, Hoboken, NJ 07030, USA Jossey-Bass, 989 Market Street, San Francisco, CA 94103-1741, USA Wiley-VCH Verlag GmbH, Boschstr.
    [Show full text]
  • Patch-Clamp Analysis of Spontaneous Synaptic Currents in Supraoptic Neuroendocrine Cells of the Rat Hypothalamus
    The Journal of Neuroscience, June 1993, 13(6): 2323-2331 Patch-Clamp Analysis of Spontaneous Synaptic Currents in Supraoptic Neuroendocrine Cells of the Rat Hypothalamus Jean-Pierre Wuarin and F. Edward Dudek Mental Retardation Research Center and the Laboratory of Neuroendocrinology of the Brain Research Institute, UCLA School of Medicine, Los Angeles, California 90024 Spontaneous synaptic currents were recorded in supraoptic Magnocellular neuroendocrine cells of the supraoptic nucleus magnocellular neurosecretory cells using whole-cell patch- have long been considered as a model system for a wide range clamp techniques in the rat hypothalamic slice preparation. of studies on neurosecretion. These neuroendocrine cells syn- Numerous spontaneous excitatory and inhibitory postsyn- thesize the neuropeptide hormones oxytocin and vasopressin aptic currents (EPSCs and IPSCs) were observed in the 27 and transport them, from their cell bodies in the supraoptic and cells recorded. The rate of occurrence of the spontaneous paraventricular nuclei, along their axons to the neurohypophysis currents and the relative proportion of EPSCs versus IPSCs where they are secreted directly in the general circulation. The varied significantly from cell to cell. Miniature EPSCs and supraoptic nucleus has particular advantages for electrophysi- IPSCs were clearly distinguished from background noise in ological studies on neuroendocrine cells because,unlike other TTX (n = 3 cells at 0.5 pglml). The frequency of EPSCs and hypothalamic nuclei, virtually all of these cells project to the IPSCs decreased by approximately 70% and the largest neurohyphophysis and are therefore neuroendocrine. Numerous events were blocked in TTX, but the peaks of the amplitude substances(e.g., ACh, norepinephrine, opioid peptides, dopa- histograms were shifted by only a few picoamperes.
    [Show full text]
  • Mechanism of Positive Allosteric Modulators Acting on AMPA Receptors
    The Journal of Neuroscience, September 28, 2005 • 25(39):9027–9036 • 9027 Cellular/Molecular Mechanism of Positive Allosteric Modulators Acting on AMPA Receptors Rongsheng Jin,1 Suzanne Clark,4 Autumn M. Weeks,4 Joshua T. Dudman,2 Eric Gouaux,1,3 and Kathryn M. Partin4 1Department of Biochemistry and Molecular Biophysics, 2Center for Neurobiology and Behavior, and 3Howard Hughes Medical Institute, Columbia University, New York, New York 10032, and 4Department of Biomedical Sciences, Division of Neuroscience, Colorado State University, Fort Collins, Colorado 80523 Ligand-gated ion channels involved in the modulation of synaptic strength are the AMPA, kainate, and NMDA glutamate receptors. Small molecules that potentiate AMPA receptor currents relieve cognitive deficits caused by neurodegenerative diseases such as Alzheimer’s disease and show promise in the treatment of depression. Previously, there has been limited understanding of the molecular mechanism of action for AMPA receptor potentiators. Here we present cocrystal structures of the glutamate receptor GluR2 S1S2 ligand-binding domain in complex with aniracetam [1-(4-methoxybenzoyl)-2-pyrrolidinone] or CX614 (pyrrolidino-1,3-oxazino benzo-1,4-dioxan-10- one), two AMPA receptor potentiators that preferentially slow AMPA receptor deactivation. Both potentiators bind within the dimer interface of the nondesensitized receptor at a common site located on the twofold axis of molecular symmetry. Importantly, the poten- tiator binding site is adjacent to the “hinge” in the ligand-binding core “clamshell” that undergoes conformational rearrangement after glutamatebinding.Usingrapidsolutionexchange,patch-clampelectrophysiologyexperiments,weshowthatpointmutationsofresidues that interact with potentiators in the cocrystal disrupt potentiator function. We suggest that the potentiators slow deactivation by stabilizing the clamshell in its closed-cleft, glutamate-bound conformation.
    [Show full text]
  • Recording Techniques
    Electrophysiological Recording Techniques Wen-Jun Gao, PH.D. Drexel University College of Medicine Goal of Physiological Recording To detect the communication signals between neurons in real time (μs to hours) • Current clamp – measure membrane potential, PSPs, action potentials, resting membrane potential • Voltage clamp – measure membrane current, PSCs, voltage-ligand activated conductances 1 Current is conserved at a branch point A Typical Electrical Circuit Example of an electrical circuit with various parts. Current always flows in a complete circuit. 2 Resistors and Conductors Summation of Conductance: Conductances in parallel summate together, whether they are resistors or channels. Ohm's Law For electrophysiology, perhaps the most important law of electricity is Ohm's law. The potential difference between two points linked by a current path with a conductance G and a current I is: 3 Representative Voltmeter with Infinite Resistance Instruments used to measure potentials must have a very high input resistance Rin. Capacitors and Their Electrical Fields A charge Q is stored in a capacitor of value C held at a potential DeltaV. Q = C* delta V capacitance 4 Capacitors in Parallel Add Their Values Currents Through Capacitors Membrane Behavior Compared with an Electrical Current A A membrane behaves electrically like a capacitance in parallel with a resistance. B Now, if we apply a pulse of current to the circuit, the current first charges up the Response of an RC parallel capacitance, then changes circuit to a step of current the voltage 5 The voltage V(t) approaches steady state along an exponential time course: The steady-state value Vinf (also called the infinite-time or equilibrium value) does not depend on the capacitance; it is simply determined by the current I and the membrane resistance R: This is just Ohm's law, of course; but when the membrane capacitance is in the circuit, the voltage is not reached immediately.
    [Show full text]
  • The Current-/Voltage-Clamp
    SimNeuron Tutorial 1 SimNeuron Current-and Voltage-Clamp Experiments in Virtual Laboratories Tutorial Contents: 1. Lab Design 2. Basic CURRENT-CLAMP Experiments 2.1 Action Potential, Conductances and Currents. 2.2 Passive Responses and Local Potentials 2.3 The Effects of Stimulus Amplitude and Duration. 2.4 Induction of Action Potential Sequences 2.5 How to get a New Neuron? 3. Basic VOLTAGE-CLAMP Experiments 3.1 Capacitive and Voltage-dependent Currents 3.2 RC-Compensation 3.3 Inward and outward currents. 3.4 Changed command potentials. 3.5 I-V-Curves and “Reversal Potential” 3.6 Reversal Potentials 3.7 Tail Currents 4. The Neuron Editor 5. Pre-Settings 2 SimNeuron Tutorial 1. Lab Design We have kept the screen design as simple as possible for easy accessible voltage- and current-clamp experiments, not so much focusing on technical details of experimentation but on a thorough understanding of neuronal excitability in comparison of current-clamp and voltage-clamp recordings. The Current-Clamp lab and Voltage-Clamp lab are organized in the same way. On the left hand side, there is a selection box of the already available neurons with several control buttons for your recordings, including a schematic drawing the experimental set-up. The main part of the screen (on the right) is reserved for the diagrams where stimuli can be set and recordings will be displayed. Initially, you will be in the Current-Clamp mode where you will only see a current-pulse (in red) in the lower diagram while the upper diagram should be empty. Entering the Voltage-Clamp mode you will find a voltage-pulse in the upper diagram (in blue) with an empty lower diagram.
    [Show full text]
  • Ion Channel Pharmacology Under Flow: Automation Via Well-Plate Microfluidics
    ORIGINAL ARTICLE Ion Channel Pharmacology Under Flow: Automation Via Well-Plate Microfluidics C. Ian Spencer,1,* Nianzhen Li,1 Qin Chen,1 Juliette Johnson,1 INTRODUCTION Tanner Nevill,1 Juha Kammonen,2,{ and Cristian Ionescu-Zanetti1 he patch clamp technique is known to provide accurate details on the conduction and gating properties of ion 1Fluxion Biosciences, Inc., South San Francisco, California. channels, yet its usefulness for drug discovery is limited by 2Pfizer Global Research and Development, Sandwich, T a characteristically slow data accumulation rate. Accord- United Kingdom. ingly, several types of automated patch clamp (APC) systems have *Present address: The Gladstone Institute of Cardiovascular been devised to enable pharmaceutical laboratories to pursue ion Disease, San Francisco, California. channel targets at relatively high throughput.1–5 In most of the {Present address: Pfizer Neusentis, Cambridge, United Kingdom. commercial automated electrophysiology platforms, glass patch pi- pettes have been replaced by a planar substrate incorporating nu- merous holes of subcellular dimensions.6–9 Cell capture by suction ABSTRACT allows for many patch-clamping sites on the planar surface and Automated patch clamping addresses the need for high-throughput simple perfusion systems have been replaced by fluid-handling ro- screening of chemical entities that alter ion channel function. As a bots. For higher throughput, whole-cell currents are summated from result, there is considerable utility in the pharmaceutical screening populations
    [Show full text]
  • Noninvasive Measurements of the Membrane Potential and Gabaergic Action in Hippocampal Interneurons
    The Journal of Neuroscience, April 1, 1999, 19(7):2546–2555 Noninvasive Measurements of the Membrane Potential and GABAergic Action in Hippocampal Interneurons Jos A. H. Verheugen, Desdemona Fricker, and Richard Miles Laboratoire de Neurobiologie Cellulaire et Moleculaire, Institut National de la Sante´ et de la Recherche Me´ dicale U261, Institut Pasteur, 75724 Paris, France Neurotransmitters affect the membrane potential (Vm ) of target a cell-attached patch. Applying the method to interneurons in cells by modulating the activity of receptor-linked ion channels. hippocampal brain slices yielded more negative values for Vm The direction and amplitude of the resulting transmembrane than subsequent whole-cell current-clamp measurements from current depend on the resting level of Vm and the gradient the same cell, presumably reflecting the development of a across the membrane of permeant ion species. Vm , in addition, Donnan potential between cytoplasm and pipette solution in governs the activation state of voltage-gated channels. Knowl- the whole-cell mode. Cell-attached Vm measurements were edge of the exact level of Vm is therefore crucial to evaluate the used to study GABAergic actions in intact CA1 interneurons. In nature of the neurotransmitter effect. However, the traditional 1- to 3-week-old rats, bath-applied GABA inhibited these cells methods to measure Vm , with microelectrodes or the whole-cell by stabilizing Vm at a level depending on contributions from current-clamp technique, have the drawback that the recording both GABAA and GABAB components. In contrast, in 1- to pipette is in contact with the cytoplasm, and dialysis with the 4-d-old animals, only GABAA receptors were activated resulting pipette solution alters the ionic composition of the interior of the in a depolarizing GABA response.
    [Show full text]
  • Voltage and Current Clamp Transients with Membrane Dielectric Loss
    VOLTAGE AND CURRENT CLAMP TRANSIENTS WITH MEMBRANE DIELECTRIC LOSS R. FITZHUGH and K. S. COLE From the Laboratory of Biophysics, National Institute ofNeurological Diseases and Stroke, National Institutes of Health, Bethesda, Maryland 20014 ABsrRAcr Transient responses of a space-clamped squid axon membrane to step changes of voltage or current are often approximated by exponential functions of time, corresponding to a series resistance and a membrane capacity of 1.0 M&F/cm2. Curtis and Cole (1938, J. Gen. Physiol. 21:757) found, however, that the membrane had a constant phase angle impedance z = zi(jwcr), with a mean a = 0.85. (a = 1.0 for an ideal capacitor; a < 1.0 may represent dielectric loss.) This result is supported by more recently published experimental data. For comparison with experiments, we have computed functions expressing voltage and current transients with constant phase angle capacitance, a parallel leakage conductance, and a series resistance, at nine values of a from 0.5 to 1.0. A series in powers of ta provided a good approxima- tion for short times; one in powers of tr, for long times; for intermediate times, a rational approximation matching both series for a finite number of terms was used. These computations may help in determining experimental series resistances and parallel leakage conductances from membrane voltage or current clamp data. INTRODUCTION The sequence of events after the application of a step change of potential across a membrane in a voltage clamp is described as: (a) a capacitive transient of current as the change of potential is being established across the capacity of the membrane, followed by (b) the linear instantaneous leakage and other currents produced by ap- preciable ionic conductances, after which (c) the current changes according to the changes of the ionic conductances.
    [Show full text]