AUTOPROGRAMMABLE ACCESS CONTROL LOCKS ACCESS CONTROL FOR EACH AND EVERYONE
TESA is launching its new access control, which employs neither software nor management systems. Its product range is simple, wireless and completely autonomous. A CUSTOMIZED SOLUTION
TESA is launching its new access control, which employs neither software nor management systems. Its product range is simple, wireless and completely autonomous.
WE CAN LOCK EVERYTHING
From a gate with a TITANIUM security padlock to a glass door with a knob from the ACCESS range. Plus ironwork doors, firebreak doors, etc.
SIMPLICITY ABOVE ALL
As long as you have a programming key/card and user 1 2 credentials, you can start the system. In a few minutes you will have an access control installed in your door.
3
TOTAL COMPATIBILITY
100% compatible with TESAs electromechanical products, and 100% compatible with TESAs armoured doors in order to ensure active and passive security and safety.
GUARANTEED BY TESA
To buy TESA is to buy quality. The use of the most advanced technology, our experienced staff and a management system certified by the ISO 9001 quality standard, the ISO 14001 environmental standard and the security and hazard prevention standard are proof of our commitment with constant innovation and growth. PROXIMITY LOCK PROXIMITY READER
PAG.5 PAG.12
ELECTRONIC CYLINDER ELECTRONIC KEY
PAG.18 PAG.20
TITANIUM PADLOCK ACCESS KNOB PAG.21 PAG.22 IDENTIFICATION TECHNOLOGY
13.56 MHz RFID contactless CHIP technology
» Higher capacity and data protection » The absence of contact between the CHIP and » High transmission speed the reader allows for a higher durability and a low maintenance cost. » Security: information is encrypted. » Multiple applications: POS, vending, consumer loyalty schemes, etc.
Credentials
» The identification item can be a card, a key ring, a bracelet, a watch, etc. » It can integrate with other technologies support formats: magnetic stripe cards, 125 kHz proximity, contact CHIP, etc. » Highly resistant to outdoors conditions, tampering, water, dust, extreme temperatures.
Design for technology: no SOFTWARE required
» No software required. » The AutoProgrammable management kit, which includes a programming kit and 25 user cards, is enough to have the program started. » A battery KIT allows to supply the lock with power every time it runs out of batteries.
1 2 3 IDENTIFICATION TECHNOLOGY
Design and functionality
» Its narrow design allows for installation in all kinds of doors. » Optional integration of a variety of handles and mortise locks. » Two lock models: long plate, and a model with a separate reader and a handle.
SecurityDiseño y andfuncionalidad comfort
» Wireless installation. Power supply: standard batteries. » All control elements (except the reader module) are located in the inside, for a higher anti-tampering security. » In case the lock doesnt open, the external handle spins free in order to avoid the risk of being forced open. » It can integrate an European profile-type mechanical cylinder for mechanical openings.
6 TECHNICAL FEATURES
Models
Long plate models. Short plate models. External side. External side.
Long plate Visible cylinder Hidden cylinder Short plate
Functions
Models with electronic privacy: (the Models without electronic privacy: (the internal side is always the same in both internal side is always the same in both the long plate and short plate models). the long plate and short plate models).
Internal deadbolt Neither cylinder nor External cylinder internal deadbolt
Internal deadbolt and external Cylinder with an Cylinder with an internal cylinder internal button button and an external key
Handles
Vector Sena Xara Zafira Pomo
7 TECHNICAL FEATURES
Resistance Finishes
Standard: for internal doors. Iron clutch. No sealing joints.
Extreme: for external doors subject to extreme conditions. Stainless steel clutch. Sealing joints.
Stainless Matt brass PVD
Polished brass PVD Black paint
Operation conditions Packaging
Up to 85% without condensation » Supplied in one1/1 single box including Humidity and External side -20ºC - 70ºC handles, screws, batteries and the template temperature for installation. Internal side -0ºC - 50ºC » The mortise lock and the cylinder are not Fireproof certificate: 30', 60' y 90' included. Fire UNE - EN 2634: 2000
Factory settings
» Locks are supplied in their factory settings, with factory cards, for an easy installation. » Before the system is programmed, these cards will open every lock.
8 TECHNICAL FEATURES
Mechanical and Electronic
LONG PLATE SHORT PLATE NUECA DE 8 CON GIRO MAX DE 42º SIN PREGIRO External cover side 40,5 X 281 X 10 mm 40,5 X 281 X 10 mm Covers Internal cover side 40,5 X 281 X 21 mm Internal cover side Stainless steel
Compatible with standard European mortise locks with a distance between Mortise shafts from 70mm to 105mm, as long as the size of the locks follower rod Locks 70/72/85/92/105 MAX 140 is 8 or 9mm, with a maximum turning capacity of 42º and no previous spin.
Width of the For doors with a thickness between 33m and 110 mm. The locks squares door (telescopic) have different sizes depending on their thickness. X and Y sizes must be supplied.
13.56 Mhz (Smartair) reading and writing Identification technology contactless chip. ISO 14443A Phillips Mifare Classic 1K, 4K Reader module Reading distance 10 mm with standard credentials
The jack that connects with the emergency power supply is located in the reader module YX
Non-volatile memory INTERNAL EXTERNAL Control Number of users limited to 500 Unit
Warning LED red and green
Type of batteries 3 1,5 V alkaline batteries (LR03 AAA type)
Battery module Estimated duration 20,000 operations, or 2-3 years
Standby consumption 40 µA
9 COMPATIBILITY OF TESAS PRODUCTS
Mortise Locks
The Smartair electronic lock is compatible with a wide range of TESAs mortise locks here are a few examples:
Standards doors: Wood
2UB0 Series (to be used with a cylinder) and 2UB0 (to be used with a deadbolt) » Silent, reversible latch with 17mm projection. » Exit panic function. » Distance between shafts: 85 mm. » 50, 60 and 70 mm backsets » Ask for other options.
2UB4 2UB0
Standards doors: Ironwork
Serie 2215 » Just the latch, for passage doors. » Stainless steel fronts. » Distance between shafts: 85 mm. » 30mm and 35mm backsets. » Ask for other options.
2215
10 Security doors: Wood
TPB3 Series (locking point by bolts)/ TPG3 (high and low locking point by hooks)
» When spinning the handles upwards, the locking points are projected. » Exit panic function. » Anticard device. » 60mm backset.
25 149
20 149 120 120
73 73 280
20
TPB3 596 120
73
12 12 196 238 238 26 26
20 20 60 60 246
20 120 646
73 280 20 25 120 120 TPG3 73 73 161 161
11 WALL READER
The reader activates the locking element with a relay: electric strike, electromagnetic/motorized lock, etc. 12Vac/Vdc external power supply required.
CN1 12Vac/Vdc power supply
Standby consumption 80 uA CN2 Connectors Consumption with operating relay: 150 mA Relay backset: NO, NC and C. CN3 Cut capacity: 5A 250Vac/5A 30Vdc
CLR RESET button for the erasing of the readers memory
Humidity Up to 85% without condensation
Operation Temperature -10ºC - 80ºC conditions Noises of the electric strike: we recommend installing the VARISTOR (which is included in the package) in the electric strike in order to absorb the noises it may produce. ALTERNATING CURRENT ONLY
PackagingDiseño y funcionalidad
Supplied in one 1/1 single box with screws, the Varistor, the transformer and the installation templates.
Factory Settings
Once it has been connected to the power supply, and before it has been programmed with the programming card, the reader will remain in its factory settings and will be open with factory cards.
Installation
Typical diagram of the connection to an electric strike:
POWER SUPPLY 12V AC/DC + -
CLR BUTTON
12 - 24 DC/AC A B NC NO C
12 MOUNTINGCOMPATIBILIDAD DIAGRAM DE PRODUCTOS TESA
1. The readers holding plate. 2. Screws for the holding plate. 3. Wall reader. 4. TORX security screws for fixing the reader to the holding plate. 5. Cable connecting the reader to the relay plate. 6. Relay plate. 7. Built-in electric case (not supplied)
2 2
1
1 J1 7 R terminal ~15 ~17
6 5 1 2 3
1-ROSA-PINK-ROSE 2-GRIS-GREY-GRIS 3-AMARILLO-YELLOW-JEUNE 4-VERDE-GREEN-VERD 4 5-MARRON-BROWN-MARRON 6-BLANCO-WHITE-BLANC
13 COMPATIBILITY WITH TESA PRODUCTS
Standard doors
TESAs wall readers can activate/deactivate any electromechanical device by means of a relay. TESA brings you a wide variety of solutions.
Electric Strike
Applications: main doors, offices, corridors, small warehouses in which a low security level is required. Fail secure (access is blocked in case of powercut). Alternating current12V/0,6A
CERNORCIN NORMAL - opens with thrust
AUTOMATIC it stays open when receiving the CERAUTCIN electric thrust
CERNODCIN NORMAL + unblocking lever
CERAUDCIN AUTOMATIC + unblocking lever
Electromagnetic Strikes
Applications: archive rooms, labs, CCTV monitor rooms, distributors of electric and telephonic installations, exit ways, etc., demanding high security levels. Power supply: 12Vcc/500 mA, or 24Vcc/250mA Fail safe (free access in case of powercut)
CEM300SS0F Rim model holding force: 300 kg
CEM600SS0F Rim model holding force: 600 kg
CEM750SS0F Mortise model holding force: 750 kg
CEM150SS0F Mortise model holding force: 1500 kg
Security doors
Applications requiring a high security level
Electromechanical locks
SOLENOIDE TEL500 SERIES The electric signal activates the external handle and allows the opening. Aplicaciones: internal doors of public buildings, companies, panic exit ways, indoors premises, staircases, lifts, garages, warehouses, etc. Models available for wooden doors and ironwork profiles. Security: both fail safe and secure (optional).
14 COMPATIBILITY WITH TESA PRODUCTS
Security Doors
Security doors: TEL600 Series
An engine removes the lever from the lock and the latch is unblocked.
Applications: doors with a high turnover, high security accesses (without an external handle). Companies, public buildings, hospitals, education centers, shopping malls, etc. Model available for both wooden/ironwork profile doors. Fail secure (in case of power cut, access remains locked).
Security doors: Bolt Series
The electric signal removes the bolt, allowing access by merely pushing the door. It includes a cable that interconnects several locks and prevents the opening of more than one door at a time (special air lock function).
Applications: internal doors, public access, air locks, narrow-profile doors, etc. Models available for both fail safe and fail secure operation, with activation via a cylinder and/or a handle, and backsets in 25 and 35 mm.
Emergency Exits
Doors that require the presence of a panic bar in order to ensure peoples safety.
Emergency Exits: TEMPRO (exit panic, motorized)
An engine removes the strike from the exit panic bar.
Applications: Emergency exits with outward exit ways in hospitals, stadiums, shopping malls, airports, museums, cinemas, etc. Fail secure (in case of power cut, access remains blocked).
Vías de Escape con Cerradura Electromecánica
The electric signal activates the external handle or the engine that removes the lever from the electromagnetic lock.
Applications: inward exit ways in hospitals, shopping malls, public buildings, etc.
Fail safe or fail secure (depending on the electromagnetic lock model).
15 COMPATIBILIDADAUTOPROGRAMMABLE DE PRODUCTOS MANAGEMENT TESA KIT
In order to start using an autoprogrammable SmartAir access control we require neither costly computer systems nor learning to use complex managements programs. All we need is a Programming card (which identifies an installation, making it different from the rest) and as many cards as users are required by the installation.
TESA has brought together all these elements in a kit, along with a simple tool that performs emergency openings when the system runs out of batteries.
PROGRAMMING CARD Its unique, exclusive code will allow to program as many locks as is required by the installation. You can rest assured that no other programming card will be taken into account from that moment on.
25 USER CARDS Ready to be included in the list of users allowed by each door, they will have to be presented to the lock before theyve been allowed access.
SIMPLE FUNCTIONALITY
By installing three AAA batteries in this element, and once it has been connected to the lock, we will be able to replace the internal batteries in case the system runs out of them. Once its been connected, the door will allow access to any authorized card.
16 SIMPLE FUNCTIONALITY
The SmartAir card brings you all the advantages and flexibility of the access control offline lock while at the same time sidestepping the complications derived from the management devices they include.
USERS REGISTER 1.Open the programming mode with the programming card. 2. Show users card (as many as one wishes to register). 3. Close the programming mode (it will close after 10 seconds of inactivity).
123
DELETE USERS 1) Open the programming mode with the programming card. 2) Show users card (as many as one wishes to delete). 3) Close the programming mode (it will close after 10 seconds of inactivity).
123
CANCEL LOST CARDS 1), 2) and 3) Bring the programming card near the access control three times.
123
OPENING WITH USED UP BATTERIES
1) In case of low battery, the lock will flash when the card is brought near. 2) Connect the battery kit device. 3) Bring the card of a valid user near in order to open the door and replace the batteries of the lock.
123
17 COMPATIBILIDADELECTRICFUNCIONALIDAD CYLINDER DE SIN PRODUCTOS COMPLICACIONES TESA
Design and Functionality
» Instant installation, just as a mechanical cylinder. » The cylinder has no power supply. The key supplies the energy required in order to open, » Autoprogrammable system you just need a programming key and users keys.
Security and Comfort
» All the monitoring elements are located inside the cylinder, and therefore protected: control unit, reader and deadbolt device. » In the outdoors version, the electronic cylinder is resistant to water and to adverse climatic conditions. » It is possible to have a stock of replacement cylinders that can be easily recorded and integrated with the installation. » It is possible to combine in one installation TESAs mechanical and electronic cylinders.
ELECTRONIC KEY
Security and Comfort
» Non-volatile memory of the key. No information will be lost when the battery is used up or replaced. » Protected data prevent the key from duplication. » One only red authorization key for each installation ensures that only the person in charge of the key will be able to record keys and cylinders.
Identification technology
» Reading and writing contact chip. » Great capacity for storing and protecting data. » Encrypted data transmission between the cylinder and the key.
18 TECHNICAL FEATURES OF THE ELECTRONIC CYLINDER
Types of Cylinders
All the necessary elements (control unit, reader and motorized clutch) are located in one side of the cylinder, with a minimum length of 35mm.
Options
Standard For internal doors
Half cylinder Water-resistant. Designed with an internal draining Version system. All the electronic elements have been silicon-coated Outdoors and protected with sealing joints. IP54 degree of protection from humidity and condensation.
Half cylinder 35x10 mm. Minimum Double cylinder 35 x 35 mm. Lengths 5mm intervals in any side with a maximum total (for Supplements both sides) of 120 mm or 75 mm on one side. Ask for other sizes.
Electronic - Electronic 13,2 mm Ironwork doors with eccentric lock 13,2
Eccentric 15 mm Other doors
Nickel
Finishes Polished brass PVD
Electronic - Buttom
Operation conditions
Humidity Up to 85% without condensation
Temperature -20ºC / 70ºC
Electronic - Mechanical
19 TECHNICAL FEATURES OF THE ELECTRONIC KEY
Types of keys
Options
Electronic Key (Uncarved) for installations with electronic cylinders
T80 carved key To be combined with mechanical cylinders (T80 system)
Electronic Key TX80 carved key To be combined with mechanical cylinders (TX80 system)
Technical Features
Size 95 x 36 x 9 mm. T80 carved key
Tecnology Contact chip
Type of battery: CR 2032 Li-Mn 3V Power supply Estimated duration: > 10,000 operations
Green LED: authorized access. Warning LED Red LED: denied access. Flashing LED: low battery warning
TX80 carved key
Change of Battery
Low battery warning When the system is starting to run out of batteries, the key will warn us via the warning LED, with a flashing red light. The battery will have to be replaced as soon as possible. Change of battery The chips memory is non-volatile.
DESMHOW TO REMOVE THE With the aid of a screwdriver, remove the lid on the BATTERYs LID opposite side to the LED.
To remove the battery
INSERT THE BATTERY Insert the battery with the positive side looking upwards. Once the battery has been installed, the key is supplied with power and in dont erase mode.
To insert the battery
20 COMPATIBILITY WITH TESAS PRODUCTS
Mechanical cylinders
T80 System The electronic key can be carved. SE groove
TX80b system The electronic key can only be carved in TESA. TS groove
T80
TX80
Titanium Padlocks
» High security padlock. » Double security high resistance ball lock. » Tempered and chromed steel case. » Hytrel protecting lid. » The cylinders protection system. » Non-removable key with an open padlock. » Anti-shear, CT60AP model anti-lever, and anti-removal. » STX electronic cylinder.
CT60 model CT60AP model
21 COMPATIBILITY WITH TESAS PRODUCTS
Outdoors Escutcheons E210 and E700
They have a sealing joint between the escutcheon and the doors leaf, a draining system and a protecting lid.
Access range knob
The new range of Access knobs gives a different solution for every type of door:
» Wooden door » Ironwork door » Glass door » Emergency exits.
The external knob is fixed and must be opened with a key. The internal knob is free. The system of the latch includes a square and an anticard security device.
Coma Luna Mira Neva
22 AUTOPROGRAMMABLE MANAGEMENT KIT
The autoprogrammable cylinder brings you all the advantages and flexibility of the access control offline cylinder while at the same time sidestepping the complications derived from the management devices they include.
The autoprogrammable management Kit includes: a (red) programming card and three (grey) user keys.
USERS REGISTER 1) Start the programming sequence by inserting the (red) programming key in the cylinder. The keys light will shine in red and green colours several times.
2 Insert the key you wish to authorize. The keys light will shine in green, flashing several times.
Repeat steps 1 and 2 for each key you wish to register in the cylinder.
12
DELETE USERS 1) Start the programming sequence by inserting the (red) programming key in the cylinder. The keys light will shine in red and green colours several times.
2) Insert the key you wish to delete. The keys light will shine in red, flashing several times.
Repeat steps 1 and 2 for each key you wish to delete from the cylinder.
12
ERASE ALL 1) Start the programming sequence by inserting the (red) programming key in the cylinder. The keys light will shine in red and green colours several times.
2) Insert for the second time the programming key. The keys light will shine in red, flashing quickly several times. The cylinder is warning us that total erasure is going to take place.
3) Insert for the third time the programming key. The keys light will shine in red permanently for a few seconds. The cylinder is now empty.
1 2 3
23 ASSA ABLOY is the worlds leading manufacturer and supplier of locking solutions, meeting tough-enduser demandsforsafety, securityanduserfriendliness. April 2009 Barrio Ventas, 35·E-20305IrunGuipúzcoa Talleres deEscoriaza,S.A.U. Tel.: +34943669100 Fax: +34943633221 www.tesa.es
AUTOPROGRAMMABLE ACCESS CONTROL