Easy Automation The flexible system for easy automation PHOENIX CONTACT – in dialog with customers and partners worldwide

Phoenix Contact is a global market leader in Estonia the field of electrical engineering, Belarus electronics, and automation. Founded in 1923, the family-owned company now Cyprus

Morocco Tunisia Qatar employs around 12,800 people Algeria worldwide. A sales network with over 50 sales subsidiaries and more than 30 additional sales partners guarantees customer proximity directly on site, anywhere in the world. Our range of services consists of products surrounding various different electrotechnical applications. This includes numerous connection technologies for Global player with personal customer contact device manufacturers and machine building, Company independence is an integral part of our components for modern control cabinets, corporate policy. Phoenix Contact therefore relies on in-house competence and expertise in a range of and tailor-made solutions for many contexts: the design and development departments applications and industries, such as constantly come up with innovative product ideas, developing special solutions to meet customer automobile production, wind energy, requirements. Numerous patents emphasize the fact photovoltaics, the process industry or that many of Phoenix Contact's products have been developed in-house. applications in the field of water supply, power distribution, and transportation infrastructure.

2 PHOENIX CONTACT The turn-key solution from a single source Contents Possible applications for Automation does not have to be expensive or complicated. The Easy Easy Automation 04 – 05 Automation system from Phoenix Contact is proof of that. It is optimized for System overview small to medium-sized applications, which you can automate easily and cost- 06 – 07 effectively with Easy Automation. Class 100 modular small-scale controllers 08 – 11 Create your individual solution from the comprehensive system covering all Function blocks 12 – 13 aspects of the class 100 modular small-scale controllers. Your advantage: all the components are coordinated, their complexity has been reduced, and they are I/O system for the inexpensive. This means that you can implement an automation solution for control cabinet 14 – 17 your system that is easy to operate and consistent. I/O system for field installation 18 – 19 Web-based automation for more efficiency Network safety solutions 20 – 21 The class 100 programmable logic controllers are designed in a modular way, as real team players, and work perfectly with numerous I/O and special function Panels for operation and monitoring 22 – 23 modules, web panels, and network components. A particular highlight is that all the controllers feature an integrated web server. This means that you can Industrial remote communication 24 – 25 access the PLC using a standard browser. So if you are on the go, you do not need any additional software to perform your control and regulation tasks. Industrial network technology 26 – 27 Service and support 28 – 29 For additional information on Easy Automation, please also visit: www.phoenixcontact.com Technical data 30 – 31

ETHERNET

PHOENIX CONTACT 3 The right automation solution for every task: Easy Automation

Water and wastewater treatment Solar energy

In water management, a modular small-scale controller can be used Monitoring is the key to efficient roof-top and free-standing as distributed intelligence (a remote terminal unit), for example, photovoltaic systems. Easy Automation not only allows you to which ensures the reliable automation of sewage treatment control the complete system, but also to implement continuous plants, waterworks, and external stations. The PLC controls the monitoring. interaction between wells, pumps, and elevated tanks. Your user advantages: Your user advantages: • Increased efficiency: acquire energy and performance data, • Permanently reliable supply, thanks to continuous connection store on SQL server, and evaluate to the higher-level control system, e.g., with integrated GSM • Reliable PV system monitoring – detect electrical interference modem or contamination quickly • Flexible adaptation of the remote control station, thanks to • Easy and inexpensive operation and monitoring, thanks to the modular structure integrated web server and WebVisit visualization software • Connection to existing systems with standardized protocols such as IEC 60870-5-101/104

PWR Switch FL BT EP A FL BT EPA PWR BluetBluetooth Ethernet Port Adapter Bluetooth Ethernet Port Adapter Ord. No.: 26927882692788 ))) Ord. No.: 2692788 )))

LAN LAN SQL server Control Wireless communication Small-scale room Small-scale controller controller Small-scale controller Web Inline panel Communication module I/O modules Energy meter

Small-scale controller String monitoring Up to 8 PV strings

per measuring module 4 - 20 mA Inline HART Flow meter Voltage measuring I/O modules module PV system

4 PHOENIX CONTACT Versatile and cost-effective Discover the numerous possible applications of the Easy Automation system. As required, you can extend the modular small-scale controllers with input and output modules and automate applications ranging from waterworks to machine building and system manufacturing.

Power transmission and distribution Machine building

In order to ensure optimum network availability, local network In machine building, the modular small-scale controllers are stations and the power quality must be monitored. The used in test equipment, for example, to control grippers, supply of renewable energy must be controlled. For this we levers or adapters. Thanks to the integrated motion functions, offer small-scale controllers that support modular expansion particularly precise and dynamic machines can be designed. and, taking the specifications of the network operator into Your user advantages: consideration, provide a tailor-made control solution. • Numerous functions such as 8 digital inputs and 4 digital Your user advantages: outputs • Easy parameterization, thanks to integrated web server • PROFINET device functionality, realtime clock, and mass • Connection to existing SCADA systems storage in a confined space • Communication via standardized transmission media and • Ideal for closed-loop control circuits and positioning tasks, protocols such as IEC 60870-5-101/104 thanks to special I/O devices and floating point unit • Secure data transmission with security routers (ILC 191 ME)

Network control center

Modem: X20INX21 OUT PHOENIX CONTACT GmbH Co. KG Flachsmarktstrasse 8 D-32825 Blomberg [email protected]

analog, DSL, D R1 Inline TR wireless Small-scale frequency controller ESC Enter inverter

UPS X10X11

Network Power storage

1x T 30A 32V

Incremental Mobile encoder phone router Media redundancy

Pneumatic gripper Switch Small-scale Local network MoveVelocity MoveAbsolute controller station Security router

PHOENIX CONTACT 5 Our system for modular small-scale controllers: A lot of automation for a small amount of money

For the inexpensive automation of your application, Phoenix Contact offers a Easy networking complete system for all aspects of the class Industrial network technology 100 modular small-scale controllers. All the Use reliable network components such as wireless components in this system are optimally solutions, switches or security routers to create networks. coordinated. Extensive interoperability tests More information from page 26 onwards ensure smooth interaction and operation. Combine the various products according to your requirements and create your ideal automation solution.

Connect easily worldwide Industrial remote communication Simply versatile Access your systems from anywhere in the world and integrate remote networks as I/O system for the well – with industrial telecommunications control cabinet products tailor-made for your application. Transmit input and output data using More information from page 24 onwards robust IP20 I/O modules from our versatile I/O range. More information from page 14 onwards

6 PHOENIX CONTACT Easy programming Software for programming and visualization Use the tailor-made software tools for all phases of engineering: the focus is on efficient and intuitive operation. Simply safe Easy control More information from page 11 onwards Network Class 100 modular small- safety solutions scale controllers Integrate functional safety without Modular and highly communicative – using an expensive safety controller – small-scale controllers provide the ideal with I/Os with integrated SafetyBridge easy introduction to automation. technology. More information from page 8 onwards More information from page 20 onwards

Easy connection I/O system for field installation Easy overview The I/O devices with IP65/IP67 Panels for operation and protection enable you to acquire monitoring input and output data even in harsh industrial environments. HMI devices with modern web technology are the smart solution for operating and monitoring More information from page 18 onwards machines and systems directly on site. More information from page 22 onwards

PHOENIX CONTACT 7 Class 100 modular small-scale controllers: Easy control

The ILC 1x1 series is the new generation in the modular small-scale controller range. These controllers also offer direct Most cost-effective PLC TCP integration. This means that all devices can communicate with a wide ILC 131 ETH Order No. 2700973 • Processing speed of 90 μs per range of devices without having to 1000 instructions (bit data types) be programmed. • 192 kbyte program memory and 192 kbyte mass storage In addition, the new small-scale controllers • 8 kbyte retentive mass storage • 1 INTERBUS interface and 1 Ethernet have an optional plug-in Flash memory. The interface advantage for you is that you can increase • 8 direct inputs and 4 direct outputs • I/O points: 2 k to 10 k the memory capacity as required using an • Integrated web/FTP server SD card, e.g., to add more user libraries. • OPC functionality • Optional: parameterization memory (SD)

Your advantages with the class 100 modular small-scale controllers: • Maximum flexibility in I/O connectivity - thanks to integrated fieldbus master and Modbus/TCP • Optimum communication – with integrated, freely programmable web server • Versatile use, as all common Ethernet protocols are supported • Easy to integrate in existing PROFINET networks, by means of PROFINET device functionality

8 PHOENIX CONTACT Standard PLC PLC with 2 Ethernet ports PLC with integrated FPU

ILC 151 ETH Order No. 2700974 ILC 171 ETH 2TX Order No. 2700975 ILC 191 ETH 2TX Order No. 2700976 • Processing speed of 90 μs per • Processing speed of 90 μs per • Processing speed of 90 μs per 1000 instructions (bit data types) 1000 instructions (bit data types) 1000 instructions (bit data types) • 256 kbyte program memory and 256 kbyte • 512 kbyte program memory and 512 kbyte • 1 Mbyte program memory and 1 Mbyte mass storage mass storage mass storage • 8 kbyte retentive mass storage • 48 kbyte retentive mass storage • 48 kbyte retentive mass storage • 1 INTERBUS interface and 1 Ethernet • 1 INTERBUS interface and 2 Ethernet • Integrated FPU for fast floating-point interface interfaces arithmetic • 8 direct inputs and 4 direct outputs • 8 direct inputs and 4 direct outputs • 1 INTERBUS interface and 2 Ethernet • I/O points: 4 k to 20 k • I/O points: 4 k to 36 k interfaces • Integrated web/FTP server • Integrated web/FTP server • 8 direct inputs and 4 direct outputs • OPC functionality • OPC functionality • I/O points: 4 k to 36 k • Integrated web/FTP server • Optional: parameterization memory (SD) • Optional: parameterization memory (SD) • OPC functionality • Optional: parameterization memory (SD)

PLC with extended PLC with modem temperature range Pre-assembled test structure

ILC 151 GSM/GPRS Order No. 2700977 ILC 131 ETH/XC Order No. 2701034 ILC 131 STARTER-KIT Order No. 2701835 ILC 151 ETH/XC Order No. 2701141 • Integrated GSM/GPRS modem The ILC 131 starter kit provides an easy • Processing speed of 90 μs per 1000 • Temperature range: -40°C to 55°C introduction to our controllers. instructions (bit data types) • 192 kbyte (ILC 131 ETH/XC) and 256 kbyte Components: • 1 INTERBUS interface and 1 Ethernet (ILC 151 ETH/XC) program/mass storage • 2-channel analog input terminal interface • 8 kbyte retentive mass storage • Potentiometer for analog value definition • 512 kbyte program memory and 512 kbyte • 1 INTERBUS interface and 1 Ethernet • 8-fold switch strip for specifying digital mass storage interface signals • 48 kbyte retentive mass storage • 8 direct inputs and 4 direct outputs • CAT-5 Ethernet cable and power supply • 16 direct inputs and 4 direct outputs • I/O points: 2 k/4 k to 10 k/20 k unit • I/O points: 4 k to 20 k • Integrated web/FTP server • CDs with example projects and • Integrated web/FTP server • OPC functionality documentation • OPC functionality • Optional: parameterization memory (SD) • Optional: parameterization memory (SD)

PHOENIX CONTACT 9 Class 100 modular small-scale controller versions for machine building

The ME versions of our modular small- scale controllers have been specifically developed for the requirements of machine building. They are the ideal solution when it comes to addressing drives via step motor drivers or frequency inverters. All the class 100 functions and important interfaces are integrated. This means that various drive types and sensors can be connected without any additional external modules. Depending on the version, analog or Function block library: Easy Motion incremental input channels can be used for The Easy Motion library enables easy traversing and homing processes without additional programming position detection. effort. The function blocks of the Easy Motion library are based on the PLC open standard.

Your advantages with the ME models: • Ideal for machine building, thanks to specially tailored functions • Two-channel drive control, without additional I/O components • Flexible, thanks to the direct connection of step motor drives and frequency inverters • Precise position detection with analog and incremental input channels • Modbus/RTU library for the RS-485 interface

10 PHOENIX CONTACT Small-scale controller programming PLC for drive control PLC for drive control

PC Worx EXPRESS Order No. 2988670 ILC 191 ME/AN Order No. 2700074 ILC 191 ME/INC Order No. 2700075 • Programming of class 100 controllers • 8 digital inputs and 4 digital outputs • 8 digital inputs and 4 digital outputs • Configure automation systems • 2 analog inputs and 2 analog outputs • RS-232 to PS/2 • Parameterization of Modbus and INTERBUS • RS-232 to PS/2 • RS-485/422 devices • RS-485/422 • 2-channel PWM function (5 V) • Programming languages supported: FBD, • 2-channel PWM function (5 V) – for the indirect control of step motors LD, ST – for the indirect control of step motors via the pulse/direction signal • 128 kbyte I/O data (mix) via the pulse/direction signal – generates square waves with • Supports German, English, French, Italian, – generates square waves with a controllable pulse duty factor and Spanish, and Chinese a controllable pulse duty factor and frequency • Available as a free download frequency • 2 fast counters (max. 200 kHz) • 10 V reference voltage source • 2 incremental encoder inputs

Reliable and precise axis control

ILC 191 ME/AN ILC 191 ME/AN Order-No.: 2700074 Order-No.: 2700074 HW/FW: 00/100 RDYFAILBSA PF HW/FW: 00/100 RDYFAILBSA PF MAC Addr. 8Block: FR E I1 I2 S1 S5 O1 O2 MAC Addr. 8Block: FR E I1 I2 S1 S5 O1 O2

xx. xx. xx. xx UL FF I3 I4 xx. xx. xx. xx UL FF I3 I4

AUTOMATIONWORX US SF Q1 Q2 I5 I6 P1 P2 AUTOMATIONWORX US SF Q1 Q2 I5 I6 P1 P2 UM SF Q3 Q4 I7 I8 D1 D2 TxD RxD UM SF Q3 Q4 I7 I8 D1 D2 TxD RxD The ME versions of the modular

X1 X1

MRESET MRESET RESET RESET OP OP ST ST small-scale controllers offer RUN/PROG PWR RUN/PROG PWR Nr. Function Voltage Nr. Function Voltage PRG PRG

X1 Power In 24 V X1 Power In 24 V ACT or ACT X2 dig. Out 24 V X2 dig. Out 24 V X2.1 X2.1 X3 dig. In 24 V X3 dig. In 24 V Ethernet, RS-485 or pulse/ LNK LNK X4 PWM / PTO 5 V X4 PWM / PTO 5 V

X5 RS485/422 X5 RS485/422 Power supply ACT ACT

X6 analog In 0 - 10 V X6 analog In 0 - 10 V X2.2 X2.2 X7 analog Out 0 - 10 V X7 analog Out 0 - 10 V direction interfaces. This means LNK LNK that electric motors can be ILC 191 ME/AN ILC 191 ME/INC driven via frequency inverters or other power electronics. In X20 IN X21 OUT PHOENIX CONTACT Communication interface GmbH Co. KG Flachsmarktstrasse 8 D-32825 Blomberg [email protected] addition, limit switches and home D R1R1 Incremental TR Laser measurement system encoder position switches are connected

ESC Enter directly to the controller.

X10 X11 24 V GND DI0DI1 DI2DI3 DI4AOAI COM NC NO Limit switch Limit switch Analog inputs (ILC 191 ME/AN) Home position switch Power are available for the position electronics detection of a tool using a Laser beam laser measuring system, for example. The ILC 191 ME/INC offers digital sensor inputs for incremental encoders.

Electric motor

0 102030405060

PHOENIX CONTACT 11 Function blocks: Quick and easy controller expansion

Modular controllers from Phoenix Contact can be adapted to any requirement quickly and easily using SD cards and function Function blocks blocks. This means that parameterization SD FLASH APPLIC A… 2 GB memories, licenses for function block Order No. 2701190 libraries or completely tested applications Flash memory with license key for the can be installed at a later time, without the function block libraries, e.g.: • Data transfer between the controller need for additional hardware. and SQL database by means of SQL communication and Data Manipulation With the SD FLASH 512MB ILDLC FLEX, Language (DML) for example, you can turn an ILC 151 GSM/ • IT library with SMTP function, with DHCP client, DNS, and FTP client function GPRS controller into a data logger. Industry-specific function blocks are tailored to the individual requirements of a particular industry and offer considerable advantages when it comes to engineering.

Your advantages with function blocks: • Individual expansion of the controller solution with complete and tested applications such as data logging or multiplexer functions • Activation of libraries and function blocks via license keys • Parameterization memory extensions for specific applications • Uncomplicated device replacement by transferring the data via SD card

12 PHOENIX CONTACT Software for usage data Multiplexer function for acquisition Software for data logging retrofitting

SD FLASH 2GB EMWISE... SD FLASH 512 MB ILDLC FLEX SD FLASH 512 MB MODULAR MUX – IMPULS Order No. 2701745 Order No. 2701875 Order No. 2701872 – IMP ANALOG Order No. 2701746 Software for integrating a complete data Software for setting up a multiplexer function logger function into a class 100 modular with two ILC 171 ETH 2TX controllers. – EXTENDED Order No. 2701747 controller. • Easy configuration, thanks to the small Software for energy data acquisition with • The software contains all applications from number of wire jumpers class 100 modular controllers. the FLEX data logger kit • Wireless, Ethernet cable or network • IMPULS: reading from measuring devices via • In conjunction with the ILC 151 GSM/GPRS connection pulses modular controller, 3 digital and 4 analog • No programming necessary • IMP ANALOG: reading from measuring input or output terminal blocks can be devices via pulses and analog values mounted • EXTENDED: reading from measuring devices via pulses, analog values, M-bus, Modbus/RTU, and IO-Link

Flexible and fast expansion via SD cards

SQL server Digital Analog PC input input

Mobile device Digital Analog output output Small-scale controller with Flow meter I/O modules

Digital Digital output input Two modular small-scale controllers Ethernet Compressed air meter Ethernet PSC's pulse counter 1 … 50

PSC's synchronization Energy meter Modular small-scale pulse controller with ILDLC FLEX application Digital Analog output input Load relay Digital Analog input output Signal Digital lamp sensor

Acquisition of usage data Data logging function Multiplexer function

PHOENIX CONTACT 13 I/O system for the control cabinet: Easy installation

The focus is on flexibility: the Inline I/O system offers practically all the functions you will require for your automation. You I/O planning just need to mount the I/O modules on the small-scale controllers. You can therefore PROJECT+ Order No. 2988667 • Free software for planning the I/O quickly and easily extend the functions of configuration your controller. • Automated creation of Inline (IP20) and Fieldline (IP65/IP67) I/O stations The principle of “plugging instead of wiring” • Automatic selection of accessories • Representation of the configured station simplifies setup and saves installation time. structure Thanks to the fine granularity of the modules, • Automatic creation of parts lists • Export to CLIP PROJECT and PC Worx you have a cost-effective automation solution, software as you only need to include the functions that • Project report via MS Word and MS Excel you actually require.

Your advantages with the IP20 I/O modules: • Flexible use, thanks to the wide range of functions • Tailor-made station structure with high granularity • Particularly maintenance friendly, thanks to plug-in modules

14 PHOENIX CONTACT Digital input/output Analog input/output Temperature recording

IB IL 24 D…PAC IB IL A…PAC IB IL TEMP…PAC Order No.: see catalog Order No.: see catalog Order No..: see catalog Signal level: 24 V DC or 120/230 V AC • Voltage and current signals: • Temperature control for resistance • PNP and NPN inputs/outputs 0 to 20 mA/4 to 20 mA temperature detectors 0 to 10 V/-10 V to +10 V • 1 to 32 channels • For type K, J, E, R, S, T, B, N, U, L, C, W, • Inputs: • Resolution: 12 to 16 bits HK thermocouples – Standard inputs according to EN • 1 to 8 channels • Resolution: 16 bits 61131-2/type 1 and type 3 • Integrated sensor supply • 1 to 8 channels – 1 to 4-conductor connection • With HART protocol • Evaluation of motor PTC thermistors – Sensor supply with extended diagnostics • Outputs: – 500 mA outputs/2 A outputs, optional, 1 to 3-conductor connection – Relay output, PDT, 5 to 50 V DC, 5 to 253 V AC, 2 A and 10 A

Serial communication Strain gauge IO-Link master

IB IL RS…-PAC IB IL SGI…PAC IB IL 24 IOL 4 DI 12-PAC Order No.: see catalog Order No.: see catalog Order No. 2692717 • Serial interface: RS-232, RS-422, RS-485) Connection of load cells, force and mass • 4 IO-Link ports for transmitting process • Coupling of scanners, barcode readers, pressure transducers and service data. The IO-Link ports can scales, printers • Connection of strain gauges in 4 and 6-wire also be used in SIO mode as a 24 V input • Baud rate can be selected up to technology or output. 250,000 baud • Resolution: 16 and 24 bit • Additional 12 digital inputs, 24 V DC according to EN 61131-2/type 3 • 3964R protocol • Sensitivity: 1 mV/V to 4 mV/V • 2 or 3-conductor connection • XON/XOFF protocol • Calibratable version available • Modbus/RTU (ASCII) • Summation of measured values with parallel connection of the strain gauges • 2 channels

A list of all products relating to I/O systems for the control cabinet can be found on the Internet at: phoenixcontact.com PHOENIX CONTACT 15 Special function modules for the Inline I/O system: Simply versatile

The Inline I/O system can be used to design tailor-made solutions to connect sensors and actuators to the relevant Pulse/frequency counter network or bus system. IB IL CNT-PAC Order No. 2861852 Power measurement terminals combine • 5 V/24 V signal level the practical Inline design with innovative • Pulse counting up to f < 100 kHz (24 bits) • Frequency/speed measurement up to measuring technology. This means that you f < 100 kHz (24 bits) can acquire energy and consumption values • Time/interval measurement up to 16 bits • Additional control input (gate) directly from your I/O system and forward • Digital output which can be controlled from them for evaluation or storage. the counter

Energy data acquisition – your key to success: • Easy energy cost controls • Improve energy efficiency • Make all consumption costs transparent • Detect and stop unnecessary energy consumption • Improve the degree of efficiency and utilization

16 PHOENIX CONTACT Position detection Connection of IP20 and IP67 Pulse generator

IB IL A…PAC Order No..: see catalog IB IL 24 FLM-PAC Order No. 2736903 IB IL PWM/2-PAC Order No. 2861632 • For incremental/absolute encoders Inline branch terminal for connecting Fieldline • Generates square wave pulses: • Symmetrical/asymmetrical signals M12 or M8 devices. – With controllable pulse/pause ratio • Homing function • An adapter is available for the transition – With controllable frequency • Supports linear/rotary encoders from M12 to M8 devices • 5 V/24 V signal level • Magnetostrictive encoders • Connects Fieldline devices to an Inline • For indirect step motor control • Start/stop encoders station easily (pulse direction signal) • Ramp generator available as a function block

Increase energy efficiency

Power measurement terminal

IB IL PM 3P/N/EF-PAC Order No. 2700965 • For analyzing AC networks, e.g., in distribution systems: for measuring current, voltage, and power, as well as identifying Energy costs that are continuously on easily via software counting functions or distortion and harmonics the rise bring the challenge of reducing via the IB IL CNT-PAC counter. All further • Direct current measurement up to 5 A/AC load on production equipment, which has loads to be analyzed are targeted and • Measurement of the neutral conductor increased over the years. connected upstream using the new Inline current To use energy efficiently, the individual power measurement terminal • Supports direct connection of 3 inputs for current and energy consumption must be (IB IL PM 3P/N/EF-PAC). phase conductor voltages up to 690 V AC tailored as precisely as possible. The class 100 modular small-scale controllers are therefore the ideal solution: consumption values are acquired

PHOENIX CONTACT 17 I/O system for field installation: Easy connection

From the control cabinet right down to field level: Phoenix Contact offers a wide range of I/O systems with IP65/ M8/M12 digital input/output IP67 protection. This means that you can connect sensors and actuators to the FLM … M8/M12 Order No.: see catalog • Digital signals with 2 or 3-conductor control level quickly and easily. connection • Signal level: 24 V DC The wireless I/O devices enable you to • Standard inputs according to EN 61131-2/ integrate your time-critical signals from type 1 • Overload protected sensor supply moving or difficult to access system parts • 500 mA/2 A outputs, can be selected wirelessly in your system. • 8 or 16 digital inputs • 8 digital outputs In addition to M12 components, you can • 4 digital inputs and 4 digital outputs • 8 digital inputs and 8 digital outputs also use compact M8 versions of the I/O • Connection method of inputs or outputs: devices where space is limited. Thanks to M8 or M12 connector the user-friendly connection technology, this not only saves space, but also time.

M12 analog input/output

FLM … M12 Order No.: see catalog • IP67 analog signals • 4 channels • Voltage and current signals: 0 to 20 mA/4 to 20 mA 0 to 10 V/-10 V to +10 V • Resolution: 15 bits • For resistance temperature detectors e.g., Pt 100, Pt 1000, Ni 1000, KTY 81, and KTY 84

18 PHOENIX CONTACT M12 IO-Link master Wireless I/O devices Wireless I/O devices

FLM IOL 4 DI 4 M12 Order No. 2736990 FLM BT BS 3 Order No. 2736770 FLM BT DI 16 M12 Order No. 2693208 • 4 IO-Link ports for transmitting process • Bluetooth base station in the Fieldline • Bluetooth IO slave and service data. The IO-Link ports can Modular local bus • 16 digital inputs also be used in SIO mode as a 24 V input • Master for up to 3 BT IO slaves • 24 V DC or output • Including antenna • 2, 3, 4-conductor connection • Additional 4 digital inputs, 24 V DC • Black channel listing • Including antenna and • 2 or 3-conductor connection • Low emission mode FLM BT ID-PLUG M12

Complex I/O communication – made easy

Inline Custom design complex I/O communication from field and control cabinet systems quickly and easily. Max. 40 m/max. 16 devices Integrate the Fieldline I/O systems seamlessly into your E.g., Inline IP20 I/O system. Thanks to PROFINET bus openness, you can connect Adapter both I/O systems flexibly to Max. 20 m virtually any network.

Actuator Sensor

Fieldline Fieldline Modular M12 Modular M8

Power cable T-distributor

PHOENIX CONTACT 19 Network safety solutions: Simply safe

The easiest way to integrate safety in your system: intelligent, safe I/O modules with SafetyBridge technology. Here the safety Freely selectable function is processed directly in the I/O controller modules. In this way, you can implement functional safety without the need for an expensive Bus Safe I/O Safe logic coupler module module safety controller or a safe fieldbus system. Emergency The safe I/O modules can be distributed in stop your network as required. Actuator How does SafetyBridge technology work? Modules with SafetyBridge technology exchange safe signals via an automation network. This standard controller and the existing network are hereby only used as a transport medium. The SafetyBridge logic module generates and monitors the SafetyBridge protocol and processes the safety-related application program.

Your advantages with I/O modules with SafetyBridge technology: • Easy integration into the standard network • Central or distributed installation enables you to meet the requirements of functional safety technology • Easy configuration using the SAFECONF software • Supports all common automation networks • Secure wireless communication

20 PHOENIX CONTACT Logic modules Output modules Input modules

IB IL 24 LPSDO 8 V2-PAC IB IL 24 PSDO 4/4-PAC IB IL 24 PSDI 16-PAC Order No. 2700606 Order No. 2916493 Order No. 2700994 IB IL 24 LPSDO 8 V3-PAC • 4 safe digital outputs which includes one • 8 safe digital inputs for 2-channel positive and one negative switching output assignment or 16 safe digital inputs for Order No. 2701625 depending on the parameterization 1-channel assignment The SafetyBridge logic modules generate and monitor the SafetyBridge protocol and process the safety program. IB IL 24 PSDO 8-PAC IB IL 24 PSDI 8-PAC Order No. 2985631 Order No. 2985688 • V2 version can be linked to up to 5 safe input or output modules • 4 safe digital outputs for 2-channel • 4 safe digital inputs for 2-channel assignment or 8 safe digital outputs for assignment or 8 safe digital inputs for • V3 version can be linked to up to 16 1-channel assignment 1-channel assignment safe input or output modules and cross communication is supported

Relay module Pre-assembled test structure Configuration software

IB IL 24 PSDOR 4-PAC ILC 130 SBT V2 STARTERKIT SAFECONF Order No. 2985864 Order No.: 2700993 Order No. 2986119 • Safety-related distributed relay output • Finished configuration of display board • Easy, standard-compliant configuration of module consisting of a modular small-scale safety devices • 4 safe digital relay outputs, each with controller, safety modules, and an example • User-friendly creation of the safety logic for 2 contacts project PSR-TRISAFE and SafetyBridge technology • The functions of a SafetyBridge system can via drag & drop be simulated and visualized • Available as a free download

PHOENIX CONTACT 21 Panels for operation and monitoring: Easy overview

Keep an eye on your application at all times and intervene in processes if required. Using HMI devices from Phoenix Contact, you can Minitouch design cost-effective solutions for operation and monitoring. TD 1030T Order No. 2701257 • 7.1 cm (2.8") TFT touch display For example, the Minitouch is extremely • 2-bit color depth, 4 colors can be displayed • 320 x 240 pixel resolution compact and ideal for cost-sensitive • LED backlighting applications where information needs to be • 120 MHz CPU, 512 kB Flash, 96 kB SRAM displayed in alphanumeric format. • 1 x Ethernet • RTOS and nano browser included Web panels from Phoenix Contact can also • IP54 on the front, IP20 on the back • Temperature range: 0°C to 50°C perform graphical visualization tasks. Using the WebVisit software, you can create customized user interfaces for this purpose. With display sizes ranging from 4 to 15 inches, you will find the right solution for every system. Your advantages with the Minitouch: • Fast startup, thanks to several predefined user interfaces • No additional software or licenses required, as the visualization is parameterized via PC WORX EXPRESS • Easy integration into existing systems, thanks to the Ethernet interface • Inexpensive visualization unit: compact, communicative, tailor-made for small to medium-sized applications

PC WORX EXPRESS Compact Controller Programming

22 PHOENIX CONTACT Web panel Widescreen web panel Outdoor web panel

WP 04T Order No. 2913632 WP 07T/WS Order No. 2700307 WP 06T/WT Order No. 2400163 WP 06T Order No. 2913645 WP 09T/WS Order No. 2700309 WP 07T/WT Order No. 2400164 WP 10T Order No. 2700934 • 17.8 cm (7") - 22.9 cm (9") • 14.5 cm (5.7") - 17.8 cm (7") WP 15T Order No. 2700935 • TFT display, 65535 colors • TFT display, 65535 colors • 8.9 cm (3.5") - 37.8 cm (15") • 800 x 480 pixel resolution • 320 x 240/800 x 480 pixel resolution • TFT display, 65535 colors • 32 MB Flash mass storage • Mass storage: 64 MB Flash • 320 x 240 / 800 x 600 / 1024 x 768 pixel • RAM: 64 MB SDRAM • RAM: 128 MB SDRAM resolution • 1 x Ethernet, 2 x USB • 1 x Ethernet RJ45, 2 x USB • LED backlighting • Windows CE and micro browser included • Windows CE and micro browser included • 32 MB Flash mass storage • Temperature range: 0°C to 50°C • Degree of protection: IP67/IP20 • RAM: 64 MB SDRAM • Temperature range: -20°C to 70°C • 1 x Ethernet, 2 x USB • Windows CE and micro browser included • Temperature range: 0°C to 50°C

Easy visualization with WebVisit

WebVisit enables you to easily create directly via the controller's integrated web user interfaces for your visualization. server. No additional software or runtime It also allows quick and user-friendly licenses are required. representation of your control variables. Monitor your system or machine via a PC using a standard browser or via a web panel using the micro browser. User Remote control also poses no problem interface Web visualization with WebVisit. The visualization is created WEBVISIT 6 – EXPRESS Order No. 2700954 Browser – BASIC Order No. 2700948 Switch – PRO Order No. 2700949

PC • Visualization editor Firewall • Enables user interfaces to be created quickly, thanks to easy handling • Optimally integrates into the workflow, Project thanks to data coupling with PC Worx and Web Server PC Worx EXPRESS

PLC

PHOENIX CONTACT 23 Industrial remote communication: Easy worldwide connections

Are you looking for a way to communicate reliably and securely with remote machines and system parts? The industrial New mobile communication products telecommunications products provide easy TC MOBILE I/O X200 solutions for efficient remote maintenance, Order No. 2903805 continuous data acquisition or automatic TC MOBILE I/O X300 early alarm generation. We offer the right Order No. 2903807 TC MOBILE I/O X200 AC device for every application: for all Order No. 2903806 transmission technologies, transmission TC MOBILE I/O X300 AC Order No. 2903808 media, and interfaces. • Monitor digital and analog sensors • Alarm in the event of exceeding and falling below the reference pattern • Relay switching of up to 4 relays via mobile phone • SMS info in the event of a power failure

Your advantages with the TC MOBILE signaling system: • Suitable for buildings and harsh industrial environments • Monitoring of sensors 0...20 mA • Monitoring of voltages up to 60 V • Relay switching via the mobile phone network • SMS, e-mail, and OPD communication • Large supply voltage range for AC or DC

24 PHOENIX CONTACT • Two SIMcard slotsfor maximum • rates High data • transmission data Encrypted • Access theInternet viamobile TC MGUARD RS40003GVPN TC MGUARD RS20003GVPN PSI-MODEM-3G/ROUTER Mobile phone redundancy availability, thanksto mobilephonenetwork communication The rightconnection for every application analog telephone network, andcoppercables. Remote access andsafe communication viathemobilephonenetwork, the

Co nfiguration LAN2 LAN1 P2 P1 Stat Err SIM SIM 2 2 SIMSIM 1 1 M Fa Mo 2 ult d In In fo fo 1 2

GPSANT LAN3 LAN4 router Mobile phone Order No. 2903440 Order No. 2903441 Order No. 2314008 Ethernet LAN modem • Easy handling • Easy • High level ofimmunity to interference communication • Stable • Via thefixed network connectionto the PSI-MODEM/ETH TC DSLROUTER X500A/B TC DSLROUTER X400A/B Internet ulctlpoentokPrivate network Public telephone network Order No. 2313300 Order No. 2902710 Order No. 2902709

TC DSL ROUTER X400B A/ Internet DS PO Ord.-No: 29 02 709 L WE R

LAN DSL router DSL Ethernet • Network remote very devices over • Ethernet, PROFIBUS, andserialdata • Refit oldsystems costeffectively • Use theexistingcableinfrastructure PSI-MODEM-SHDSL/SERIAL PSI-MODEM-SHDSL/PB PSI-MODEM-SHDSL/ETH distances ofupto 20km distances transmission extender Ethernet PHOENIX CONTACT Order No. 2313669 Order No. 2313656 Order No. 2313643

25 Industrial network technology: Easy networking

Looking for an easy and inexpensive way to network your modular small- scale controllers based automation Bluetooth Ethernet adapter system? Then you need reliable network components that can be easily integrated FL BT EPA AIR SET Order No. 2693091 • Ready-to-use set including all accessories into your automation infrastructure. Our for cable replacement comprehensive portfolio for Industrial • Establish communication in just a few seconds Ethernet covers all possibilities: wireless • Data transmission via Bluetooth solutions for easy cable replacement, high- • Integrated special antenna • IP65 protection performance switches, and security routers • Max. transmission power: 20 dBm with integrated firewall for system safety and • Power consumption of < 1.1 W secure remote maintenance. FL BT EPA Order No. 2692788 • Individual module

We make Ethernet easy: • Switches for inexpensive and reliable Ethernet networks • Industrial firewall/router for the individual protection of distributed automation systems • Bluetooth or WLAN Ethernet adapters for easy cable replacement

26 PHOENIX CONTACT WLAN Ethernet adapter Unmanaged Switches Unmanaged FO Switches

FL WLAN EPA Order No. 2692791 FL SWITCH SFN 5TX FL SWITCH SFN 4TX/FX Order No. 2891152 Order No. 2891851 • 2 modules enable the data cable to be replaced • 5 RJ45 ports • 4 RJ45 ports/1 SC multi-mode port • Data transmission via WLAN according to FL SWITCH SFN 8TX IEEE 802.11 b/g FL SWITCH SFN 6TX/2FX Order No. 2891929 Order No. 2891314 • Integrated special antenna • 8 RJ45 ports • Security thanks to data encryption • 6 RJ45 ports/2 SC multi-mode ports • Fast installation, thanks to plug and play • Fast installation, thanks to plug and play • IP65 protection • Prioritization of data with Quality of • Prioritization of data with Quality of • Max. transmission power: 20 dBm Service function (realtime) Service function (realtime) • Power consumption of < 1.8 W • EtherNet/IP™-compatible • EtherNet/IP™-compatible • Fiberglass uplink

Security router Unmanaged Switch Lean Managed Switches

FL MGUARD RS2000 TX/TX VPN FL SWITCH 1605 M12 FL SWITCH LM 4TX/1FX Order No. 2700642 Order No. 2700200 Order No. 2989624 • 4 RJ45 ports/1 SC multi-mode port • Secure remote maintenance of machines • Compact switch with a narrow design for and systems easy integration, e.g., on standard profiles FL SWITCH LM 4TX/2FX • Easy configuration via 2-click firewall • Quick and easy mounting Order No. 2832658 • 4 RJ45 ports/2 SC multi-mode ports • Quick and easy startup and device • Extended temperature range replacement with SD card • Low current consumption FL SWITCH LM 8TX Order No. 2832632 • Virtual addressing with the 1:1 NAT • 8 RJ45 ports function • Integrated web server for easy configuration and diagnostics • Fast redundancy switch-over • Temperature range from -40°C to +70°C • PROFINET Conformance Class A

PHOENIX CONTACT 27 Service and support: We provide support over the phone and on site

Whatever the task at hand, the technological solution you are looking for to meet your objective or the products you would like Consultation and presentation to use: our specialists are always on hand Our safety specialists will advise you on no matter where you are. Our flexible the entire safety lifecycle of your machine. service concept enables an approach on Following a safety consultation, you will know which steps you need to take, why, every imaginable level. What's more, our how, and in which sequence in order to experts have extensive knowledge of the ensure compliance with legislation. We use on-site presentations to directly industry and technology in question. This, in demonstrate the conformance process to combination with Phoenix Contact's wide your experts. range of products, means we always have the right solution for you.

Your personal contact person will provide telephone support and, in the event of a fault, will organize immediate delivery of replacement parts or on-site service.

Special services for machine safety

Detailed Consulting Order No. 2700502 Consultation to clarify your specific requirements with regard to the measures required for machinery safety

Moderation Order No. 2700504 • Process assistance for practical on-site implementation • Templates for verification documentation

28 PHOENIX CONTACT Engineering Service Training and workshops

Do you need a customized solution? We Our service teams excel thanks to their Thanks to intensive contact with our can offer you the necessary technological focused expertise, years of practical customers and years of on-site experience, expertise, combined with vast experience experience, and high degree of flexibility. we have developed a qualification concept in many industries. Our expert project Our service network is on hand to assist you whereby we can specify employee management team will guide you through during installation, startup, and operation, qualifications so as to meet your individual all the important phases of your project. even in the most remote corners of the requirements. We will offer you the Together with you, we will arrange the world. appropriate service depending on the project necessary services and handle the subtasks phase, target group, and prior knowledge. during the implementation phase.

Project Engineering Order No. 2850863 Free system hotline with 24-hour We provide support for the following: • Technical system concept using Visu+/ product support • PROFINET Genesis hardware and software-based In the event of an emergency, we can • Industrial Ethernet visualization provide you with replacement parts • Ethernet security • Support with configuring and outside of office hours. • Wireless LAN programming your application + 49 (0) 5281 9-462888 • Bluetooth • Creation of function blocks • PC Worx Hotline Specialist Order No. 2733427 • SQL database communication Personal hotline specialist for situations • Config+, Diag+, Visu+ that need to be dealt with very quickly. • WebVisit Local Service Order No. 2710123 • INTERBUS installation and startup • INTERBUS maintenance and diagnostics On-site service for: • Individual seminars and workshops • Installation • Startup • Operation

Safety Engineering Order No. 2692089 Free safety technology hotline with We provide support for the following: • Assessing safety integrity 24-hour product support • Machinery Directive • Safety specifications for machinery In the event of an emergency, we can • EN ISO 13849-1 • Programming the safety controller provide you with replacement parts outside • Machine safety practical workshop of office hours. • Creating safe function blocks • Safety lifecycle practical workshops + 49 (0) 52 81 9 46 27 77 • Verifying verification documentation • SISTEMA • Validating safety functions Safety Service Order No. 2851202 • Safety technology basics On-site service for: • INTERBUS-Safety • Installation • PROFIsafe • Startup • Individual seminars and workshops • Operation App for Android and Apple: Phoenix Contact safety Selected products at a glance – create your individual solution

Class 100 modular small-scale controllers Type

Cost-effective PLC, 192 kbyte program and mass storage, 8 kbyte retain memory, ILC 131 ETH plug-in parameterization memory (SD Flash with 512 Mbyte or 2 Gbyte), 8 digital Order No. 2700973 inputs and 4 digital outputs, Ethernet interface, web/FTP server, Modbus/TCP client integrated, from FW 4.1 with PROFINET device

Standard PLC, 256 kbyte program and data memory, 8 kbyte retain memory, plug-in ILC 151 ETH parameterization memory (SD Flash with 512 Mbyte or 2 Gbyte), 8 digital inputs Order No. 2700974 and 4 digital outputs, Ethernet interface, web/FTP server, Modbus/TCP client integrated, from FW 4.1 with PROFINET device

PLC with 2 Ethernet ports, 512 kbyte program and data memory, 48 kbyte retain ILC 171 ETH 2TX memory, plug-in parameterization memory (SD Flash with 512 Mbyte or 2 Gbyte), Order No. 2700975 8 digital inputs and 4 digital outputs, web/FTP server, Modbus/TCP client, PROFINET device

PLC with integrated FPU and 2 Ethernet ports, 512 kbyte program and data ILC 191 ETH 2TX memory, 48 kbyte retain memory, plug-in parameterization memory (SD Flash Order No. 2700976 with 512 Mbyte or 2 Gbyte), 8 digital inputs and 4 digital outputs, web/FTP server, Modbus/TCP client, PROFINET device

The ILC 191 ME/AN is particularly suited to easy drive tasks in the field of step ILC 191 ME/AN and servo motor technology. The controller has the same technical properties as Order No. 2700074 the ILC 191 ETH 2 TX with the following additional onboard interfaces: 2-channel PWM/pulse direction output, 1 RS-485/RS-422, 2 analog inputs and outputs

The ILC 191 ME/INC is particularly suited to easy drive tasks in the field of step and ILC 191 ME/INC servomotor technology. The controller has the same technical properties as the Order No. 2700075 ILC 191 ETH 2 TX with the following additional onboard interfaces: 2-channel PWM/pulse direction output, 1 RS-485/RS-422, 2 fast counters (max. 200 kHz), 2 incremental encoder inputs

PLC with integrated GSM/GPRS modem, 512 kbyte program and data memory, ILC 151 GSM/GPRS 48 kbyte retain memory, plug-in parameterization memory (SD Flash with Order No. 2700977 512 Mbyte or 2 Gbyte), 16 digital inputs and 4 digital outputs, Ethernet interface, web/FTP server, Modbus/TCP client integrated

PLCs with extended temperature range from -40°C to +60°C (with derating), ILC 131 ETH/XC 192 kbyte (ILC 131 ETH/XC) or 256 kbyte (ILC 151 ETH/XC) program and mass Order No. 2701034 storage, 8 kbyte retain memory, plug-in parameterization memory (SD Flash with 512 Mbyte or 2 Gbyte), 8 digital inputs and 4 digital outputs, Ethernet interface, ILC 151 ETH/XC web/FTP server, Modbus/TCP client integrated, from FW 4.1 with PROFINET device Order No. 2701141

Private network Type

Ethernet extender for network extension via copper cables, for point-to-point PSI-MODEM-SHDSL/ETH connections, line and ring structures, distances up to 20 km, data rates up to Order No. 2313643 30 Mbps, diagnostic function, two configurable alarm outputs

PROFIBUS extender for network extension via simple copper wires such as in-house PSI-MODEM-SHDSL/PB phone lines, for point-to-point connections, line structures, and mixed operation with Order No. 2313656 repeater and FO converter, distances up to 20 km, PROFIBUS data rates up to 1.5 Mbps

Serial extender for RS-232, RS-422, and RS-485 communication via in-house cables, PSI-MODEM-SHDSL/SERIAL for point-to-point connections and line structures, distances up to 20 km, serial data Order No. 2313669 transmission speeds up to 2000 kbps, integrated diagnostic function, two configurable alarm outputs

30 PHOENIX CONTACT Public telephone network Type

DSL modem, broadband router (firewall), Annex A and Annex B support (reversible TC DSL ROUTER X400 A/B via web-based management) Order No. 2902709

DSL modem, broadband router (firewall), Annex A and Annex B support (reversible TC DSL ROUTER X500 A/B via web-based management), VPN tunneling, NAT table, RS-232 interface, digital Order No. 2902710 inputs and outputs

Analog Ethernet modem for dial-up operation, 10...30 V DC supply voltage PSI-MODEM-ETH Order No. 2313300

Analog modem with RS-232 interface for dial-up and permanent line operation, PSI-DATA/FAX-MODEM/RS232 10...60 V DC/16...40 V AC supply voltage Order No. 2708203

Analog modem with USB interface for dial-up operation (up to 56 kbps), supply PSI-MODEM-BASIC/USB voltage via USB connection Order No. 2313436

HMIs for basic applications – web panels Type

Web panel, 8.9 cm (3.5")/14.5 cm (5.7")/26.4 cm (10.4")/38.1 cm (15") TFT color WP 04T Order No. 2913632 display, 65535 colors, 320 x 240/800 x 600 pixels (SVGA)/1024 x 768 pixels (XGA) WP 06T Order No. 2913645 resolution, LED background lighting, 32 Mbyte Flash mass storage, RAM: 64 Mbyte WP 10T Order No. 2700934 SDRAM, including 1 x Ethernet, 2 x USB, Windows CE, and micro browser, WP 15T Order No. 2700935 temperature range: 0 °C to 50 °C

Widescreen web panel, 17.8 cm (7")/22.9 cm (9") TFT color display, 65535 colors, WP 07T/WS Order No.: 2700307 800 x 480 pixels resolution, 32 MB Flash mass storage, RAM: 64 MB SDRAM, WP 09T/WS Order No.: 2700309 including 1 x Ethernet, 2 x USB, Windows CE, and micro browser, temperature range: 0 °C to 50 °C

Outdoor web panel, 14.5 cm (5.7")/17.8 cm (7") TFT display, 65535 colors, WP 06T/WT Order No.: 320 x 240/800 x 480 pixels resolution, 32 MB Flash mass storage, RAM: 64 MB 2400163 SDRAM, including 1 x Ethernet, 2 x USB, Windows CE, and micro browser, WP 07T/WT Order No.: temperature range: -20 °C to 70 °C 2400164

Mobile phone Type

Serial quad band modem for GPRS and GSM, 10 ...30 V DC supply voltage PSI-GPRS/GSM-MODEM/ RS232-QB Order No. 2313106 Monitor digital and analog sensors as well as switching remote relays via mobile TC MOBILE I/O X200 communication, communication via SMS, e-mail or ODP (GPRS), voltage supply: Order No. 2903805 10...60 V DC. TC MOBILE I/O X300 Order No. 2903807 Switch remote relays via mobile communication and monitor digital inputs, TC MOBILE I/O X200 AC communication via SMS, e-mail or ODP (GPRS), voltage supply: 93...250 V AC. Order No. 2903806 TC MOBILE I/O X300 AC Order No. 2903808 GPRS/EDGE mobile phone router with Ethernet interface, up to 3 VPN tunnels, PSI-MODEM-GSM/ETH GSM quad band, stateful inspection firewall Order No. 2313355

UMTS/HSPA mobile phone router with Ethernet interface, up to 3 VPN tunnels, PSI-MODEM-3G-ROUTER 3 UMTS, and 4 GSM frequency ranges, 2 SIM slots, stateful inspection firewall Order No. 2314008

Mobile phone router with MGUARD technology, manageable 4-port switch, RS-232 TC MGUARD RS4000 3G VPN interface, GPS interface, up to 10 VPN tunnels (can be increased to 250 by means of Order No. 2903440 additional license), 5 UMTS, and 4 GSM frequency ranges, CDMA support, 2 SIM slots, stateful inspection firewall, redundant voltage supply possible

Mobile phone router with MGUARD technology, 4-port switch, RS-232 interface, TC MGUARD RS2000 3G VPN GPS interface, up to 2 VPN tunnels, 5 UMTS, and 4 GSM frequency ranges, CDMA Order No. 2903441 support, 2 SIM slots, 2-click firewall

PHOENIX CONTACT 31 a: 4 () 2 5 - 1 00 +49 (0) 12 52 35 phoenixcontact.com3-4 Fax: +49 (0) 52 35 3-00 Phone: 32825 Blomberg,Germany PHOENIX CONTACT GmbH&Co. KG • I/O systems • I/O • HMIs andindustrialPCs safety • Functional • Fieldbus componentsandsystems • Electronic switchgear and housing • Electronics • Controllers • Connectors • Cables andwires range Product motor control • PCB terminal blocksand • Monitoring • Modular terminal blocks • Measurement andcontrol technology • Marking andlabeling • Lighting andsignaling • andmountingmaterial Installation Ethernet • Industrial • Industrial communication technology PCB connectors phoenixcontact.com and service: you'll find everythingonourproducts, solutions Always up-to-date,always available to you. Here • Wireless communication data • Tools • System cablingfor controllers • Surge protection andinterference filters • Software cabling • Sensor/actuator • Relaymodules • Protectivedevices • Power supply unitsandUPS

CIS15-13.000.L3 Printed in Germany MNR 52004726/2014-04-01/02 © PHOENIX CONTACT 2014