Spot Vision Screener Sample Results
Total Page:16
File Type:pdf, Size:1020Kb
Spot Vision Screener Sample Results Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 1 Table of Contents Understanding the Spot Display Data Display . 3 Printed Report . 4 Printed Label Report . 5 Instant Screening Results Displayed . .. 6 Definitive Results Samples Screening Complete . 7 Myopia . 8 Hyperopia . 9 Anisometropia . .. 10 Astigmatism . 11 Strabismus . 12 Anisocoria . 13 Glossary of Terms . 14 Support . 15 Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 2 Data Display pupillary distance pupil size indicator • alignment indicator • degree: OD = Right Eye vertical or OS = Left Eye horizontal • complete refraction +/- cylinder convention • SE = spherical equivalent DS = sphere DC = cylinder Axis = axis Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 3 Printed Report ( paper ) Vision screening does not replace Complete Eye Exam A a complete eye examination by B an ophthalmologist or optometrist. Recommended A Disclaimer PediaVision is a registered trademark of PediaVision Holdings, LLC. The Spot logo and information in this report are the trademarks and property of PediaVision Holdings, LLC. Copyright ©2012 by PediaVision Holdings, LLC. All rights reserved. B Screening Result Vision Screening Summary SUBJECT ID 21081-13572 D E C Date/Time of Test C SCREENING 01/17/2014 4:27 pm GENDER F AGE 3Y FIRST NAME Olivia D Demographic Information LAST NAME Dylan Vision screening should be conducted regularly as eyes may change over time. POTENTIAL CONDITION E Photo of Subject • Hyperopia (OD) [ farsighted ] 6.0 77 6.0 mm mm mm F Data Display (see page 3 for detail) ➜ ➜ • Astigmatism (OD) [ problem focusing ] 1° R L 1° ➜ 4° ➜ 0° - CYL F • Anisometropia [ unequal power] G S E S E +3.00 +1.50 OD D S D C A x i s D S D C A x i s OS G Potential Conditions +4.00 -2.00 @99° +1.75 -0.75 @16° H Right Eye & Le Eye Results RIGHT EYE LEFT EYE BOTH EYES Results (In-Range = blue, Out of Range = red) OUT OF RANGE IN RANGE IN RANGE OUT OF RANGE myopia J Analysis of Both Eyes hyeropia H J astigmatism anisocoria anisometropia gaze asymmetrygaze K Customizable Banner gaze dev. Learn more about vision screening at: K SpotVisionScreening.com LEVY123456789_20120529_174320_OutOfRange_0_100000.pdf PRINTED ON 05-25-2012 7:53 PM Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 4 Printed Label Report ( size* ) A Demographic Information A B Cylinder Convention +/- B C OD/OS Refractions C D Pupil Size Indicator D E E Pupillary Distance F F Alignment Indicator G H G Potential Condition H Date/Time of Test *Requires Brother QL-720NW label printer as defined in the “Instructions for Use” . Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 5 Instant Screening Results Displayed “Screening Complete” with the indication of “Complete Eye Exam Recommended” with “All Measurements in Range” is consistent indication of potential vision disorders is with screening results below the configurable consistent with screening results above the threshold setting . configurable threshold setting . Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 6 Screening Complete [ All Measurements in Range ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 7 Myopia [ Near-sightedness ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 8 Hyperopia [ Far-sightedness ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 9 Anisometropia [ Unequal Refractive Power ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 10 Astigmatism [ Blurred Vision ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 11 Strabismus [ Eye Misalignment, Gaze ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 12 Anisocoria [ Pupil Size Deviations ] Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 13 Glossary of Terms Refractive Measurements Pupillary Distance [PD] Myopia Consists of Sphere, Cylinder Distance between the centers Near-sightedness and Axis of the pupils in each eye Hyperopia Sphere [DS] Cylinder Convention Far-sightedness Measures the power of the eye There are two different for myopia and hyperopia conventions for indicating Anisometropia the amount of cylinder: Unequal refractive power Cylinder [DC] “plus cylinder notation” and Measures the shape of the “minus cylinder notation” Astigmatism cornea Blurred vision, eye OD [oculus dexter] structure problem Axis Right eye Measurable location of Anisocoria astigmatism OS [oculus sinister] Pupil size deviations Left eye Spherical Equivalent [SE] Strabismus Equal to the sum of the value Binocular Eye misalignment, Gaze of the sphere and half Both eyes of the cylinder Monocular One eye Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 14 For more information, visit: Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved. 15.