Applied Biosystems 7500 Real-Time PCR System and Applied Biosystems 7500 Fast Real-Time PCR System a Real Fast and Real Versatile Approach to Real-Time PCR

Total Page:16

File Type:pdf, Size:1020Kb

Applied Biosystems 7500 Real-Time PCR System and Applied Biosystems 7500 Fast Real-Time PCR System a Real Fast and Real Versatile Approach to Real-Time PCR 58374r1_AB04499 12/15/04 10:50 PM Page 1 Specification Sheet Real-Time PCR Systems Applied Biosystems 7500 Real-Time PCR System and Applied Biosystems 7500 Fast Real-Time PCR System A Real Fast and Real Versatile Approach to Real-Time PCR • The 7500 Fast Real-Time PCR System enables standard 96-well format high speed thermal cycling, significantly reducing your run time for quantitative real-time PCR applications, deliv- ering results in about 35 minutes Applied Biosystems 7500 Real-Time PCR System Applied Biosystems 7500 Fast Real-Time PCR System • The 7500 Real-Time PCR System is a versatile, leading-edge platform providing enhanced performance •Small instrument footprint permits Fast Thermal Cycling capabilities and an upgrade path easy placement in any laboratory, The 7500 System is available in two to high-speed thermal cycling even those with limited space configurations; the 7500 Fast System configuration with a high-speed, 96- •Five-color detection system provides Introduction well format thermal cycling block the flexibility to perform a variety The Applied Biosystems 7500 and capable of quantitative real-time PCR of applications including gene 7500 Fast Real-Time PCR Systems are runs in about 35 minutes, and the expression analysis, SNP genotyp- integrated, versatile platforms for the standard configuration with a 96-well ing and plus/minus assays that detection and quantification of nucleic format thermal cycling block with utilize internal positive controls acid sequences. Real-time PCR com- run times of under 2 hours. A service bines thermal cycling, fluorescence •Advanced optical configuration engineer installed Fast Upgrade Kit detection, and application-specific supports a broader range of fluo- is available for the 7500 System to software to measure the cycle-by-cycle rophores, including FAM™/SYBR® upgrade it to the Fast configuration. accumulation of PCR products in a Green I, VIC®/JOE™, NED™/ single-tube homogenous reaction. The Applied Biosystems 7500 Fast TAMRA™/Cy3™, ROX™/Texas Red®, Real-Time PCR System delivers high- and Cy5™ dyes; variable excitation Quantitative results are available speed cycling capabilities with a new capability allows greater sensitivity immediately upon completion of fast ramping Peltier-based thermal for longer wavelength (red) dyes PCR, with no need to run gels, purify cycling block. This hardware, together PCR products, or perform any post- •Powerful, flexible software with new Optical Fast 96-well reaction PCR manipulation. Compared with includes new plate setup wizards plates and a new hot-start DNA manual PCR quantitation techniques, to guide you through experimental polymerase containing master mix, such as Northern blotting or RNase setup, while automated analysis comprise the complete Fast system. protection assays, real-time PCR offers tools such as RQ Study (Relative Using this system quantitative real- an enormous time savings, greater sen- Quantitation) gene expression time PCR runs can be completed in sitivity, superior precision, and a larger analysis software allow the simul- about 35 minutes with comparable dynamic range. taneous analysis and visualization performance to standard run times of up to ten 96-well plates of data for supported applications. www.appliedbiosystems.com 58374r1_AB04499 12/15/04 10:50 PM Page 2 The 7500 Fast System supports three Demonstrated Performance Specifications thermal cycling modes; Fast, Standard Instrument 7500 System 7500 Fast System and 9600 emulation. Standard and 9600 emulation thermal cycling modes Dynamic Range 9 logs of linear dynamic range 9 logs of linear dynamic range on the 7500 Fast System have ramp Sensitivity Detection of 10 copies of Detection of 10 copies of rates comparable to the standard 7500 template in a 50 µL reaction for template in a 20 µL reaction for ® ® System. Data collection processes for a single reporter TaqMan assay, a single reporter TaqMan assay, with 99.7% confidence with 99.7% confidence Fast 7500 Systems remain the same as for standard 7500 Systems. Run Time 1 hour and 50 minute run time 37 minute run time for a 40 cycle for a 40 cycle PCR reaction PCR reaction using the TaqMan® Real-Time PCR Applications using the TaqMan® RNase P RNase P Fast Instrument The 7500 and 7500 Fast Systems sup- Instrument Verification Plate Verification Plate port many real-time PCR applications, including gene expression analysis using relative quantitation (RQ) assays Sequence Detection Software • Automated SNP genotype calling and pathogen detection using standard Sequence Detection Software for the capability, including 2-cluster calling, curves. In addition, the systems allow 7500 and 7500 Fast systems runs on with intuitive graphical output and for qualitative post-PCR detection of the Windows XP® operating system quality-value assignment, makes SNP nucleic acids for allelic discrimination and is used for instrument control, analysis simple and straightforward (SNP genotyping assays) and data collection, and data analysis. • Simple dissociation curve data col- plus/minus assays that utilize internal Powerful and user-friendly, the soft- lection and viewing, enabling the positive controls. ware includes: addition of dissociation stages while runs are in progress Fluorescence Detection • Plate set-up wizards for easy experi- • Tool tips for easy identification of All sample wells are illuminated with a mental design, even with complex sample wells when viewing amplifica- tungsten halogen lamp. Light from this multicolor assays tion curve or SNP genotyping plots lamp passes through five excitation filters • The added ability for the 7500 Fast • Lamp-life monitoring and instrument before reaching sample wells. The System to choose between Fast, diagnostics to provide confidence in inclusion of excitation filters improves Standard, and 9600 emulation your instrument performance the ability of the instrument to excite thermal cycling modes dyes at longer (red) wavelengths, • Real-time monitoring of amplifica- Installation Specifications resulting in greater sensitivity and pre- tion growth curves enabling viewing The TaqMan® Fast RNase P cision for these dyes. Fluorescence of runs in progress Instrument Verification Plate enables emission is then detected through five • The flexibility to add extra PCR the 7500 Fast System to distinguish emission filters (even in Fast thermal cycles while runs are in progress between samples containing 5,000 and cycling mode) to a charge-coupled • Auto-baseline and auto-threshold 10,000 template DNA copies, with a device (CCD) camera. Emission filters for simplified data analysis statistical confidence level of 99.7% are optimized for use with FAM™/ • Absolute quantitation of nucleic acid and a run time of about 35 minutes. SYBR® Green I, VIC®/JOE™, targets with the ability to simulta- The TaqMan® Fast RNase P NED™/TAMRA™/Cy3™, ROX™/Texas neously analyze multiple standard Instrument Verification Plate enables Red®, and Cy5™ fluorescent dyes. curves on a single plate, improving the 7500 System to distinguish your workflow and easing the between samples containing 5,000 and burden of downstream analysis 10,000 template DNA copies, with a • RQ (Relative Quantitation) gene statistical confidence level of 99.7%. expression analysis software with powerful data viewing capabilities allowing the simultaneous analysis of up to ten 96-well plates of data www.appliedbiosystems.com 58374r1_AB04499 12/15/04 10:50 PM Page 3 Computer Specifications Instrument Specifications Applied Biosystems supplies a Dell™ Instrument 7500 System and 7500 Fast System business line computer (note book or tower) for use with the 7500 and Thermal cycling system Peltier-based, 96-well block 7500 Fast Systems. For the latest Optical system Five-excitation, Five-emission filters and CCD camera computer specifications please visit Instrument 7500 System 7500 Fast System the Applied Biosystems website at www.appliedbioystems.com Quantitative PCR run time < 2 hours < 40 minutes Reagents and Disposables Supported A complete line of reagents including Volumes 20-100 µL 10–30 µL TaqMan® Fast Universal PCR Master Supported • Standard Optical 96-well plates • Optical Fast 96-well plates ® Mix, TaqMan Universal Master Consumables • 8-strip 0.2mL tubes • Optical Adhesive Covers Mixes, SYBR® Green I Master Mixes, • 0.2mL tubes and disposables including 96-well • Optical Adhesive Covers • Optical Flat Caps plates, is available for use with the Applied Biosystems 7500 and 7500 Fast Real-Time PCR Systems. Supported Applications Service and Warranty Instrument 7500 System 7500 Fast System Purchase of the 7500 System or 7500 Standard/9600 Standard/9600 Fast System includes a one-year lim- Thermal Cycling Mode Emulation Fast Emulation* ited warranty on parts and labor. Purchase of the 7500 Fast System Absolute Quantitation Yes Yes Yes Upgrade Kit includes a 90-day limited Relative Quantitation Yes Yes Yes warranty on parts and labor. The 7500 Allelic Discrimination Yes No Yes System, 7500 Fast System and 7500 Fast Upgrade Kit include set-up and Plus/Minus Assays using IPC Yes No Yes calibration of the instrument by our *Ramp rates for Standard/9600 emulation mode are matched to the 7500 System Standard/9600 emulation highly trained Service Support team. modes. However, overall run times are shorter on the 7500 Fast System for these modes. Support Technical specialists and scientists TaqMan® Genomic Assay Products provide worldwide applications support Applied Biosystems provides preformulated, ready-to-use, quality-tested, and service. 5' nuclease TaqMan® assays for use with the 7500 and 7500 Fast systems. Assay Details Application Assay Formats Gene Expression SNP Genotyping TaqMan® Genomic Assays Yes Yes Custom TaqMan® Genomic Assays Yes Yes Genome Availability Number of Assays Human > 204,000 > 1,990,000 Mouse > 179,000N/A Rat > 128,000N/A URL (assays can be ordered online only) www.allgenes.com www.allsnps.com www.appliedbiosystems.com 58374r1_AB04499 12/15/04 10:50 PM Page 4 Instrument and Computer Dimensions Dimension 7500/7500 Fast System Notebook Tower Width 34 cm (13.39 in.) 32 cm (12.4 in.) 18 cm (7.1 in.) Depth 45 cm (17.72 in.) 26 cm (10.1 in.) 45 cm (17.6 in.) Height 49 cm (19.29 in.) 3 cm (1.2 in.
Recommended publications
  • APPLERA CORPORATION Annual Report
    312849_Applera_REVISED0914.qxd 9/17/01 6:42 PM Page 2 2001APPLERA CORPORATION Annual Report APPLIED BIOSYSTEMS CELERA GENOMICS 312849_Applera_REVISED0914.qxd 9/17/01 6:42 PM Page 3 Table of CONTENTS Letter to Stockholders Applera Corporation 3 Applied Biosystems Group 5 Celera Genomics Group 7 Celera Diagnostics 8 Financial Review 10 Directors and Officers 109 Stockholder Information 110 APPLERA CORPORATION Mission: To provide the world’s leading technology and information solutions that help life scientists understand and use the power of biology. Business Groups: Applied Biosystems and Celera Genomics Headquarters: Norwalk, Connecticut APPLIED BIOSYSTEMS GROUP Profile: A leading provider of technology solutions for life science research and related applications, with customers in over 100 countries. Headquarters: Foster City, California New York Stock Exchange Symbol: ABI CELERA GENOMICS GROUP Profile: A biopharmaceutical business and leading provider of genomic and related medical information, enabling therapeutics discovery using proprietary scientific capabilities for the group’s internal efforts and in partnership with pharmaceutical and biotechnology companies. Headquarters: Rockville, Maryland New York Stock Exchange Symbol: CRA CELERA DIAGNOSTICS Profile: A joint venture between Applied Biosystems and Celera Genomics that is leveraging capabilities from both businesses to develop new molecular and protein diagnostics. Headquarters: Alameda, California 312849_Applera_REVISED0914.qxd 9/17/01 6:42 PM Page 4 To our stockholders: Applera Corporation continues to be a leader This should allow us to more effectively in the life science revolution – a revolution many anticipate customers’ needs and bring products believe could define this new century. We enter to market in a more timely manner, while fiscal year 2002 at the threshold of major maintaining the technological innovation that advances in the field of disease diagnosis and has made us a premier provider of life science therapeutics discoveries, made possible in part by tools.
    [Show full text]
  • The Science Commons in Health Research: Structure, Function, and Value
    J Technol Transfer (2007) 32:133–156 DOI 10.1007/s10961-006-9016-9 The science commons in health research: structure, function, and value Robert Cook-Deegan Published online: 7 December 2006 Ó Springer Science+Business Media, LLC 2006 Abstract The ‘‘science commons,’’ knowledge that is widely accessible at low or no cost, is a uniquely important input to scientific advance and cumulative technological innovation. It is primarily, although not exclusively, funded by government and nonprofit sources. Much of it is produced at academic research centers, although some academic science is proprietary and some privately funded R&D enters the science commons. Science in general aspires to Mertonian norms of openness, universality, objectivity, and critical inquiry. The science commons diverges from proprietary science primarily in being open and being very broadly available. These features make the science commons particularly valuable for advancing knowledge, for training innovators who will ultimately work in both public and private sectors, and in providing a common stock of knowledge upon which all players—both public and private—can draw readily. Open science plays two important roles that pro- prietary R&D cannot: it enables practical benefits even in the absence of profitable markets for goods and services, and its lays a shared foundation for subsequent private R&D. The history of genomics in the period 1992–2004, covering two periods when genomic startup firms attracted significant private R&D investment, illustrates these features of how a science commons contributes value. Commercial interest in genomics was intense during this period. Fierce competition between private sector and public sector genomics programs was highly visible.
    [Show full text]
  • Guide to Biotechnology 2008
    guide to biotechnology 2008 research & development health bioethics innovate industrial & environmental food & agriculture biodefense Biotechnology Industry Organization 1201 Maryland Avenue, SW imagine Suite 900 Washington, DC 20024 intellectual property 202.962.9200 (phone) 202.488.6301 (fax) bio.org inform bio.org The Guide to Biotechnology is compiled by the Biotechnology Industry Organization (BIO) Editors Roxanna Guilford-Blake Debbie Strickland Contributors BIO Staff table of Contents Biotechnology: A Collection of Technologies 1 Regenerative Medicine ................................................. 36 What Is Biotechnology? .................................................. 1 Vaccines ....................................................................... 37 Cells and Biological Molecules ........................................ 1 Plant-Made Pharmaceuticals ........................................ 37 Therapeutic Development Overview .............................. 38 Biotechnology Industry Facts 2 Market Capitalization, 1994–2006 .................................. 3 Agricultural Production Applications 41 U.S. Biotech Industry Statistics: 1995–2006 ................... 3 Crop Biotechnology ...................................................... 41 U.S. Public Companies by Region, 2006 ........................ 4 Forest Biotechnology .................................................... 44 Total Financing, 1998–2007 (in billions of U.S. dollars) .... 4 Animal Biotechnology ................................................... 45 Biotech
    [Show full text]
  • On June 28, 2002, Applera Corporation
    UNITED STATES DISTRICT COURT DISTRICT OF CONNECTICUT Applera Corporation and : Roche Molecular Systems, Inc.,: plaintiffs, : : v. : 3:98cv1201 (JBA) : MJ Research Inc. and Michael : and John Finney, defendants. : Ruling on Motion of MJ Research, Inc. for Summary Judgment Determining that Plaintiffs’ Licensing Scheme Imposes a Total Sales Royalty [Doc. # 1123] and Plaintiffs’ Cross Motion for Summary Judgment Seeking a Determination that Applera’s Licensing Program does not Impose an Improper Total Sales Royalty and Thus is Not Patent Misuse [Doc. # 1153] Defendant/counterclaim plaintiff MJ Research, Inc. ["MJ"] and plaintiffs/counterclaim defendants Applera Corp.1 and Roche Molecular Systems, Inc. have filed cross motions for summary judgment on defendant’s patent misuse defense that Applera’s licensing program improperly requires suppliers to pay royalties on all thermal cycler sales, when some portion of those thermal cyclers are not used in a manner which infringes Applera's patent. While this issue previously had been raised in a summary 1On June 28, 2002, Applera Corporation and Perkin-Elmer ("PE") Corporation, its wholly owned subsidiary, entered into an agreement and liquidation plan in which PE Corporation was liquidated and the entirety of its assets, including intellectual property rights, was transferred to Applera Corporation. On June 3, 2003, this Court granted plaintiff’s motion to amend the caption in this lawsuit to reflect the official change in Plaintiff’s identity from "PE Corporation" to "Applera Corporation." See [Docs. # 664, 674]. For consistency, this Court will refer to plaintiff as Applera, even when referring to pre-2002 events. 1 judgment motion, it was not addressed in the Court's (Squatrito, J., presiding) ruling.
    [Show full text]
  • In the Supreme Court
    No. 00-1543 In the Supreme Court OF THE United States FESTO CORPORATION, Petitioner, VS. SHOKETSU KINZOKU KOGYO KABUSHIKI CO., LTD., a/k/a SMC CORPORATION AND SMC PNEUMATICS, INC. Respondents. On Petition For Writ Of Certiorari To The United States Court Of Appeals For The Federal Circuit BRIEF OF AMICUS CURIAE APPLERA CORPORATION (APPLIED BIOSYSTEMS AND CELERA GENOMICS) IN SUPPORT OF RESPONDENTS MATTHEW D. POWERS Counsel of Record EDWARD R. REINES Josh A. KREV1TT WEIL, GOTSHAL & MANGES LLP 2882 Sand Hill Road, Suite 280 Menlo Park, CA 94025 (650) 926-6200 Counsel for Amicus Curiae Applera Corporation Bowne of Los Angeles, Inc., Law Printcts (213) 627-2200 i. TABLE OF CONTENTS I. STATEMENT OF INTEREST . 1 II. INTRODUCTION . 2 III. THE PETITION SHOULD BE DENIED . 4 A. In Festo, The Federal Circuit Followed The Mandate Of This Court . 4 B. The Petition's Unsupported Doomsday Predictions Do Not Justify The Granting Of Certiorari . 5 IV. CONCLUSION . 9 ii TABLE OF AUTHORITIES Cases Aclara Biosciences, Inc. v. Caliper Technologies Corp., 125 F. Supp.2d 391 (N.D. Cal. 2000) . 7, 8 Brown v. Texas, 522 U.S. 940 (1997) . 8 Festo Corp. v. Shoketsu Kinzoku Kogyo Kabushiki Co., Ltd. 234 F.3d 558 . 2, 3, 4, 5, 6, 7, 9 Lackey v. Texas, 514 U.S. 1045 (1995) . 7, 8 McCray v. New York, 461 U.S. 961, (1983) . 6, 8 Warner-Jenkinson Company, Inc. v. Hilton Davis Chemical Co., 520 U.S. 17, 39 n.8 (1997) . 4 I. STATEMENT OF INTEREST Applera Corporation ("Applera") is a leading biotechnology company comprised of two businesses, Celera Genomics and Applied Biosystems.1 Celera Genomics seeks to become the definitive source of genomic and related biological information and has already publicly announced that it has sequenced the human genome, among others.
    [Show full text]
  • DNA Resequencing and Variant Identification on the Applied Biosystems 3130 Series Genetic Analyzers
    Application Note DNA Resequencing/Variant ID on the 3130 Series Systems DNA Resequencing and Variant Identification on the Applied Biosystems 3130 Series Genetic Analyzers Introduction Direct DNA sequencing is an accurate and proven technique for mutation detection. However, despite wide- spread use and accessibility, adapting this technique to gene resequencing projects can include challenges in primer design, PCR validation, data analysis, and data interpretation. In the course of designing more than 200,000 primer pairs and generating more than 18 million sequence reads, bioinformatics specialists and R&D scientists who worked on the Applera Genome Initiative gained valuable experience in primer design, as well as insight into the genomic complexities and technical challenges associated Figure 1. The Applied Biosystems 3130 Series Genetic Analyzers are robust, reproducible, systems that are fully with them. The experiences gained automated from the moment each 96- or 384-well plate is placed on the instrument and the run is initiated. The systems provide continuous, unattended operation, from automated polymer loading and sample injection to from the initiative revolutionized separation, detection, and data generation. The instrument also includes several new enhancements, such as a detection cell heater that improves sizing precision, thus facilitating better thermal control, an Automated Polymer DNA sequencing as a tool for the Delivery System that significantly reduces set-up time, and easy-to-use wizards for instrument operation. detection of human gene mutations. The 3130 and 3130xl Genetic sequencing as a tool for the detection Basecaller automatically processes Analyzers, when combined with the of human gene mutations. them and provides LOR (Length- Applied Biosystems VariantSEQr™ of-Read) greater than 500 base The 3130 Series Genetic Resequencing System, reagents, and Analyzers pairs (bp), with average base Quality SeqScape® Software v2.5 provide the Values greater than 20 (QV The 3130 Series Genetic Analyzers 20).
    [Show full text]
  • News Release an Applera Corporation Business 850 Lincoln Centre Drive Contacts Foster City, CA 94404-1128 U.S.A
    News Release an Applera Corporation Business 850 Lincoln Centre Drive Contacts Foster City, CA 94404-1128 U.S.A. Media Investors T (650) 570-6667 Lori Murray Peter Dworkin F (650) 572-2743 650.638.6130 650.554.2479 www.appliedbiosystems.com [email protected] [email protected] European Media & Investors David Speechly, Ph.D. + 011.44.207.868.1642 [email protected] FOR IMMEDIATE RELEASE APPLIED BIOSYSTEMS INTRODUCES NEW CHEMISTRIES TO INCREASE THE PRODUCTIVITY OF SEQUENCING FOSTER CITY, CA – September 18, 2002 – Applied Biosystems Group (NYSE:ABI), an Applera Corporation business, today announced the launch of two new versions of its BigDye® Terminator Cycle Sequencing Kit, designed to increase productivity and improve data quality for DNA sequencing applications. These enhanced products are a result of Applied Biosystems’ goal to improve sequencing technologies for rapid, accurate and cost effective DNA analysis for studying human and other genomes. BigDye® Terminator v3.1 Cycle Sequencing Kit is designed for the majority of applications, including de novo sequencing and resequencing. The BigDye® Terminator v1.1 Cycle Sequencing Kit is designed for specialty applications, such as sequencing PCR products associated with comparative sequencing when using a rapid instrument run. Together BigDye® Terminator v3.1 and v1.1 kits are expected to meet the requirements of nearly all sequencing applications performed today. These new formulations are designed to provide researchers with improved performance in sequencing difficult templates, resulting in longer read lengths and higher success rates. A large percentage of the finishing costs for production-scale sequencing projects are associated with sequencing difficult templates.
    [Show full text]
  • Applera Corp. – Applied Biosystems Group (Applera) Appeals the United
    NOTE: This disposition is nonprecedential. United States Court of Appeals for the Federal Circuit 2009-1253, -1260 APPLERA CORPORATION – APPLIED BIOSYSTEMS GROUP, Plaintiff-Appellant, v. ILLUMINA, INC. and STEPHEN C. MACEVICZ, Defendants-Appellees, and SOLEXA, INC., Defendant-Cross Appellant. Edward R. Reines, Weil, Gotshal & Manges LLP, of Redwood Shores, California, argued for plaintiff-appellant. With him on the brief was Sonal N. Mehta. Of counsel on the brief was Kurtis D. MacFerrin, Life Technologies Corporation, of Foster City, California. Kevin M. Flowers, Marshall, Gerstein & Borun LLP, of Chicago, Illinois, argued for defendants-appellees and defendant-cross appellant. With him on the brief were Thomas I. Ross, Mark H. Izraelewicz, John R. Labbe, and Cullen N. Pendleton. Appealed from: United States District Court for the Northern District of California Judge William H. Alsup NOTE: This disposition is nonprecedential. United States Court of Appeals for the Federal Circuit 2009-1253, -1260 APPLERA CORPORATION – APPLIED BIOSYSTEMS GROUP, Plaintiff-Appellant, v. ILLUMINA, INC. and STEPHEN C. MACEVICZ, Defendants-Appellees, and SOLEXA, INC., Defendant-Cross Appellant. Appeals from the United States District Court for the Northern District of California in case no. 07-CV-02845, Judge William H. Alsup. ___________________________ DECIDED: March 25, 2010 ___________________________ Before LOURIE, GAJARSA, and MOORE, Circuit Judges. MOORE, Circuit Judge. Applera Corp. – Applied Biosystems Group (Applera) appeals the United States District Court for the Northern District of California’s denial of its motions for judgment as a matter of law or, alternatively, for a new trial on ownership of U.S. Patent Nos. 5,740,341 (the ’341 patent), 5,969,119 (the ’119 patent), and 6,306,597 (the ’597 patent).
    [Show full text]
  • Entrepreneurial Experiments in Science Policy: Analyzing the Human Genome Project
    Entrepreneurial experiments in science policy: Analyzing the Human Genome Project The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation Huang, Kenneth G., and Fiona E. Murray. “Entrepreneurial Experiments in Science Policy: Analyzing the Human Genome Project.” Research Policy 39.5 (2010) : 567-582. As Published http://dx.doi.org/10.1016/j.respol.2010.02.004 Publisher Elsevier Version Author's final manuscript Citable link http://hdl.handle.net/1721.1/65078 Terms of Use Creative Commons Attribution-Noncommercial-Share Alike 3.0 Detailed Terms http://creativecommons.org/licenses/by-nc-sa/3.0/ Entrepreneurial Experiments in Science Policy: Analyzing the Human Genome Project Kenneth G. Huang Assistant Professor of Management Singapore Management University Lee Kong Chian School of Business 50 Stamford Road #05-01 Singapore, 178899 +(65) 6828-0525 [email protected] Fiona E. Murray Associate Professor of Management Massachusetts Institute of Technology Sloan School of Management 50 Memorial Drive E52-567 Cambridge, MA 02142 (617) 258-0628 [email protected] December 2009 Forthcoming Research Policy 1 Electronic copy available at: http://ssrn.com/abstract=1526536 Entrepreneurial Experiments in Science Policy: Analyzing the Human Genome Project Kenneth G. Huang Singapore Management University Lee Kong Chian School of Business Fiona E. Murray Massachusetts Institute of Technology Sloan School of Management Abstract We re-conceptualize the role of science policy makers, envisioning and illustrating their move from being simple investors in scientific projects to entrepreneurs who create the conditions for entrepreneurial experiments and initiate them. We argue that reframing science policy around the notion of conducting entrepreneurial experiments – experiments that increase the diversity of technical, organizational and institutional arrangements in which scientific research is conducted – can provide policy makers with a wider repertoire of effective interventions.
    [Show full text]
  • Automated DNA Sequencing
    Automated DNA Sequencing Chemistry Guide © Copyright 2000, Applied Biosystems For Research Use Only. Not for use in diagnostic procedures. ABI PRISM and its design, Applied Biosystems, and MicroAmp are registered trademarks of Applera Corporation or its subsidiaries in the U.S. and certain other countries. ABI, BigDye, CATALYST, POP, POP-4, POP-6, and Primer Express are trademarks of Applera Corporation or its subsidiaries in the U.S. and certain other countries. AmpliTaq, AmpliTaq Gold, and GeneAmp are registered trademarks of Roche Molecular Systems, Inc. Centricon is a registered trademark of W. R. Grace and Co. Centri-Sep is a trademark of Princeton Separations, Inc. Long Ranger is a trademark of The FMC Corporation. Macintosh and Power Macintosh are registered trademarks of Apple Computer, Inc. pGEM is a registered trademark of Promega Corporation. Contents 1 Introduction. 1-1 New DNA Sequencing Chemistry Guide . 1-1 Introduction to Automated DNA Sequencing . 1-2 ABI PRISM Sequencing Chemistries . 1-5 Applied Biosystems DNA Sequencing Instruments. 1-7 Data Collection and Analysis Settings . 1-12 2 ABI PRISM DNA Sequencing Chemistries . 2-1 Overview . 2-1 Dye Terminator Cycle Sequencing Kits . 2-2 Dye Primer Cycle Sequencing Kits . 2-8 Dye Spectra . 2-12 Chemistry/Instrument/Filter Set Compatibilities . 2-13 Dye/Base Relationships for Sequencing Chemistries . 2-14 Choosing a Sequencing Chemistry. 2-15 3 Performing DNA Sequencing Reactions . 3-1 Overview . 3-1 DNA Template Preparation . 3-2 Sequencing PCR Templates . 3-10 DNA Template Quality. 3-15 DNA Template Quantity. 3-17 Primer Design and Quantitation . 3-18 Reagent and Equipment Considerations.
    [Show full text]
  • Applied Biosystems 7500/7500 Fast Real-Time PCR System Presence/Absence Experiments
    Getting Started Guide Applied Biosystems 7500/7500 Fast Real-Time PCR System Presence/Absence Experiments Getting Started Guide Get Started Applied Biosystems 7500/7500 Fast Real-Time PCR System Presence/Absence Experiments Design the Experiment Prepare the Reactions Run the Experiment Analyze the Experiment © Copyright 2007, 2010 Applied Biosystems. All rights reserved. Information in this document is subject to change without notice. Applied Biosystems assumes no responsibility for any errors that may appear in this document. APPLIED BIOSYSTEMS DISCLAIMS ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL APPLIED BIOSYSTEMS BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF. For Research Use Only. Not for use in diagnostic procedures. NOTICE TO PURCHASER: Label License The 7500/7500 Fast Real-Time PCR System is covered by US patents and corresponding claims in their non-US counterparts, owned by Applied Biosys- tems. No right is conveyed expressly, by implication, or by estoppel under any other patent claim, such as claims to apparatus, reagents, kits, or methods such as 5 nuclease methods. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. TRADEMARKS: Applera, Applied Biosystems, AB (Design), MicroAmp, NucPrep, PrepMan, Primer Express, and VIC are registered trademarks and FAM, JOE, NED, and ROX are trademarks of Applied Biosystems or its subsidiaries in the U.S.
    [Show full text]
  • Careers in Biotechnology, a Counselor's Guide to the Best Jobs
    Careers in BIOTECHNOLOGY A Counselor’s Guide to the Best JJbobs in the UUidnited States 3rd Edition Animal Caretaker Animal Technician Bioinformatics Specialist Clinical Research Associate Documentation Coordinator Forensic DNA Analyst By Greenhouse and Field Technician Greenhouse and Field Worker Gina Frierman-Hunt Health and Safety Specialist Instrumentation/Calibration Technician Julie Solberg Laboratory Assistant Laboratory Automation Specialist California Community Colleges Laboratory Support Worker Economic Workforce Development Laboratory Technician California Applied Biotechnology Centers Manufacturing Assistant Statewide Initiative and Hubs Manufacturing Technician Material Handler Quality Assurance Specialist Quality Co nt ro l Tec hnic ia n Research Associate Sales Representative Scientist Technical Service Representative cccbiotech.org Careers in Biotechnology 3rd Edition A Counselor’s Guide to the Best Jobs in the United States By Gina Frierman‐Hunt Julie Solberg Sponsored by: California Community Colleges Economic and Workforce Development Program California Applied Biotechnology Centers and Hubs www.cccbiotech.org and Bio‐Link, a National Science Foundation Advanced Technology Education Center www.bio‐link.org © Chancellors Office California Community Colleges Careers in Biotechnology may be copied and used by educators and counselors. Please acknowledge the source when making electronic or printed copies. The third edition is a joint project of the California Applied Biotechnology Centers and Hubs, California Community Colleges Economic and Workforce Development Program and Bio-Link, a National Science Foundation Advanced Technology Education Center. The Biotechnology Centers Directors are: Los Angeles / Orange County Biotechnology Center Wendie Johnston, Ph.D. Hosted by Pasadena City College (626) 507-8488 California Applied Biotechnology Center-North Valley Director: TBA Hosted by American River College (916) 484-8660 Northern California Bay Area Biotechnology Center Josie Sette M.S.
    [Show full text]