Fluid Gaming A120 A240 A240g

Total Page:16

File Type:pdf, Size:1020Kb

Fluid Gaming A120 A240 A240g For EK-KIT A series units | 1st Revision, Apr 3rd 2017 Starter Liquid Cooling Kit FLUID GAMING A120 A240 A240G USER GUIDE EK Water Blocks bears the name of its founder Edvard König, who started experimenting with liquid cooling in 1999. From the humble be- ginnings in the early years of the previous decade, the company grew Safety precautions steadily to become a global premium liquid cooling gear manufacturer. Today, EKWB offers a complete range of products for liquid cooling, 1. Keep and store the product away from the reach of children. from a renowned Supremacy line of CPU water blocks, to a wide range 2. Check the component list and condition of the product before installation. of CoolStream radiators, from in-house developed Vardar High pressure If there is any problem, contact the shop where you have purchased the fans, to market-proven SPC series of liquid cooling pumps and thus pro- product to get a replacement or refund. vides overclocking enthusiasts and PC builders with the best of what the 3. EKWB d.o.o. is not responsible for any damages due to external causes, market can offer. Fluid Gaming kits are the next step to bring extreme including but not limited to, improper use, problems with electrical power, liquid cooling performance in the hands of dedicated gamers and PC accident, neglect, alteration, repair, improper installation and improper testing. enthusiasts around the world. 4. CPU and motherboard are subject to damage if the product is incorrectly installed. Welcome to EK-World and enjoy Fluid Gaming! 5. This product is a CPU liquid cooling solution kit, comprising of individual original EKWB parts. Combining this liquid cooling unit with parts, other than EK Water Blocks products, may lead to warranty loss. 6. Product warranty period is 24 months. This product is made from aluminum and can be only used with other aluminum liquid cooling components, such as Al fittings, water blocks and radiators. Mixing aluminum with copper and brass products can cause galvanic corrosion of the metal and render liquid cooling equipment useless. Such misuse is not covered by warranty. Do not use liquid metal TIM with aluminum products as it will result catastrophic corrosion failure! / 1 / TABLE OF CONTENT SCOPE OF DELIVERY 3 DRAINING OF THE LOOP 27 REQUIRED TOOLS 4 FREQUENTLY ASKED QUESTIONS 28 TROUBLESHOOTING 30 QUICK INSTALLATION GUIDE THE COOLER IS TOO LOUD 31 RADIATOR SPACE CONSTRAINT REQUIREMENTS 5 GENERAL LIQUID COOLING PARTS CLEANING GUIDE 31 DOZEN GOOD ADVICES FOR THE NEWCOMERS 6 PREVENTIVE STEPS 32 LIQUID COOLING SYSTEM 6 SUPPORT AND SERVICE 34 GENERAL INFORMATION ON WATER BLOCK COMPATIBILITY 7 SOCIAL MEDIA 34 INSTALLING THE WATER BLOCK 7 LGA-2011(-3) SOCKET MOTHERBOARDS 7 LGA-115X SOCKET MOTHERBOARDS 9 AMD® SOCKET AM4 MOTHERBOARDS 11 INSTALLING THE RADIATOR AND FANS 15 INSTALLING THE RADIATOR AND FANS 15 INSTALLING THE RADIATOR AND FANS IN ONE GO 17 INSTALLING THE PUMP-RESERVOIR UNIT 18 INSTALLING THE GPU WATERBLOCKS 19 CONNECTING THE TUBING 20 ELECTRICAL CONNECTIONS 22 CONNECTING THE PUMP-RESERVOIR UNIT 22 CONNECTING THE FANS 23 RECOMMENDED FILLING AND LEAK-TESTING PROCEDURE 24 FILLING THE SYSTEM FOR THE FIRST TIME 25 / 2 / SCOPE OF DELIVERY CPU water Block CPU Backplate mechanism Thermal grease CPU Mounting mechanism with AMD® mounting plate Fans Pump-Reservoir combo UNI Pump Bracket Compression fi ttings (120mm Fan) Radiator Coolant Tube ATX Bridging plug / 3 / Fan cable Y-splitter Adapter cable Installation manual REQUIRED TOOLS Phillips-head screwdriver Mixing bottle 1L Bottle of distilled water Pair of scissors H20 / 4 / RADIATOR SPACE CONSTRAINT REQUIREMENTS 120 mm (4,72 in) 27,5 mm (1,08 in) 120 mm (4,72 in) 280 mm (11,02 in) 160 mm (6,30 in) 240 120 / 5 / DOZEN GOOD ADVICES FOR THE NEWCOMERS 1. In order to make the package more compact we have decided to enclose 7. Generally, for optimal performance, the Pump should be positioned be- only the coolant concentrate for liquid cooling. Therefore you need to provide fore the Radiator in the water loop. 1 liter (1L) of distilled water. You can get it at every gas station or supermarket. 8. It is best practice to do a proper leak test before using your computer. 2. Never run this system on tap water and always use the enclosed cooling 9. If you spot any leaks, turn off the power immediately! concentrate in correct ratio. 10. Optimize tubing length in order to prevent excessive bending and kinking 3. Never use alcohol, alcohol derivatives or alcohol based solvents in the of the tubing. system. Using alcohol might result in permanent damage to water cool- 11. Never let your pump run dry. If this is happening for a prolonged pe- ing KIT components, especially acrylic parts of the system. riod of time you may risk destroying water pump’s bearing, rendering the 4. Reservoir must be positioned above the height level of the water pump pump useless. in order for liquid to flood the pump which is crucial for the fi rst start-up. 12. You are encouraged to periodically clean the radiator assembly as it will 5. Generally, for optimal performance, the Reservoir must be positioned be- collect dust over time. This is best done with soft wide tip brush and fore the pump in the water loop. vacuum cleaner. See chapter ‘General liquid cooling parts cleaning guide. 6. Generally, for optimal performance, the CPU water block should be right after the Radiator in the water loop. LIQUID COOLING SYSTEM CPU WATERBLOCK COLD AIR RADIATOR with FANS HOT AIR RESERVOIR-WATER PUMP COMBO / 6 / GENERAL INFORMATION ON WATER BLOCK COMPATIBILITY This CPU liquid cooling unit is pre-assembled for use with modern Intel® and AMD® desktop socket type motherboards. By default (out of the box) this water block supports the following CPU sockets: - Intel® Socket LGA-115x - Intel® Socket LGA-2011(-3) - AMD® Socket AM4* *requires replacing Intel® mounting plate with AMD® one. INSTALLING THE WATER BLOCK LGA-2011(-3) SOCKET MOTHERBOARDS LGA-2011 M4 Thumb Screw LGA-2011 M4 STEP 1 Thumb Screw Prepare the foil bag with mounting mechanism, which is enclosed with the CPU water block delivery. Install four (4) specific LGA-2011 M4 thumb screws into four M4 threaded stubs on the LGA-2011 socket integrated latch mechanism (ILM). The screws are to be installed using no tools (i.e. pliers). It is recommended to remove the motherboard form the PC chassis before proceeding with installation of the CPU water block because of the space constraint limitations of various computer cases. STEP 1 / 7 / STEP 2 Cleaning the CPU: Wipe the CPU’s contact surface (by using non–abrasive Non-abrasive cloth or Q-tip, as shown on sample photo). cloth Applying thermal compound: EK recommends blob or line method of ap- plying the enclosed EK-TIM Ectotherm thermal compound to the CPU heat spreader (IHS) - see sample photo on right. Thermal grease IHS The quantity of about two rice grains is just about right. There is no need to cover the whole IHS. Applying too much thermal grease will have negative impact on the cooling performance! STEP 2 STEP 3 Take the waterblock and remove the sticker on the aluminum head. Thumb nut Align the water block over the mounting screws on the LGA-2011(-3) motherboard with pre-installed CPU. Coiled spring Before proceeding with the installation It is mandatory to remove the protective foil from the backside of the water block. Place an enclosed compression spring and thumb nut over each M4 thumb screw. Start fastening two thumb nuts at a time, preferably in cross pattern and do not tighten them fully until all of them are partially screwed in. Then - using your fingers only - screw in all four thumb nuts until you reach the end of the thread. STEP 3 / 8 / LGA-115x SOCKET MOTHERBOARDS Outer part STEP 1 If already installed, please remove the motherboard from your computer and place it on an even surface with front facing down. STEP 2 Preparing backplate rubber gasket The enclosed rubber gasket is essential part of the backplate and mount- ing system and must be used every time you install this water block on your motherboard. Inner core The rubber gasket has a partially cut inner part which needs to (removable) be removed when installed on Intel LGA-115x motherboard. The STEP 1 STEP 2 rubber is held on four places and can be peeled away with hand. STEP 3 Install backplate rubber gasket and place metal backplate for Intel LGA-115x socket to the back of your motherboard RIBBED SIDE UP! (facing away Metal from the motherboard) Align the holes on the motherboard with holes on Backplate M4 Thumb Screw rubber gasket and backplate. Make sure to orientate the rubber gasket to fi t past the CPU PVC socket ILM backplate. On certain ITX form factor motherboards washer the rubber gasket may need to be trimmed using household scissors. Rubber gasket Carefully rotate motherboard assembly with front side facing up with one Motherboard hand while holding the backplate and rubber in place with the other hand. STEP 3 STEP 4 STEP 4 Install four (4) M4 thumb screws onto your motherboard. It is mandatory to put 0.7mm plastic washer underneath each of the M4 thumb screws. Tighten the screws to the metal backplate until you reach the end of the thread. Using tools (such as pliers) is not recommended. / 9 / STEP 5 Cleaning the CPU: Wipe the CPU’s contact surface (by using non–abrasive cloth or Q-tip, as shown on sample photo). Non-abrasive EK recommends blob or line method of applying the cloth Applying thermal compound: enclosed EK-TIM Ectotherm thermal compound to the CPU heat spreader (IHS) - see sample photo on right.
Recommended publications
  • Avionics Thermal Management of Airborne Electronic Equipment, 50 Years Later
    FALL 2017 electronics-cooling.com THERMAL LIVE 2017 TECHNICAL PROGRAM Avionics Thermal Management of Advances in Vapor Compression Airborne Electronic Electronics Cooling Equipment, 50 Years Later Thermal Management Considerations in High Power Coaxial Attenuators and Terminations Thermal Management of Onboard Charger in E-Vehicles Reliability of Nano-sintered Silver Die Attach Materials ESTIMATING INTERNAL AIR ThermalRESEARCH Energy Harvesting ROUNDUP: with COOLING TEMPERATURE OCTOBERNext Generation 2017 CoolingEDITION for REDUCTION IN A CLOSED BOX Automotive Electronics UTILIZING THERMOELECTRICALLY ENHANCED HEAT REJECTION Application of Metallic TIMs for Harsh Environments and Non-flat Surfaces ONLINE EVENT October 24 - 25, 2017 The Largest Single Thermal Management Event of The Year - Anywhere. Thermal Live™ is a new concept in education and networking in thermal management - a FREE 2-day online event for electronics and mechanical engineers to learn the latest in thermal management techniques and topics. Produced by Electronics Cooling® magazine, and launched in October 2015 for the first time, Thermal Live™ features webinars, roundtables, whitepapers, and videos... and there is no cost to attend. For more information about Technical Programs, Thermal Management Resources, Sponsors & Presenters please visit: thermal.live Presented by CONTENTS www.electronics-cooling.com 2 EDITORIAL PUBLISHED BY In the End, Entropy Always Wins… But Not Yet! ITEM Media 1000 Germantown Pike, F-2 Jean-Jacques (JJ) DeLisle Plymouth Meeting, PA 19462 USA
    [Show full text]
  • An Expansion on Applied Computer Cooling
    An Expansion on Applied Computer Cooling By Spencer Ellsworth LAES 400 November 29, 2012 Abstract In the world of professional technology, many businesses utilize servers and Ap- ple products in their day-to-day work, relying upon these machines for the liveli- hood of their operations. However, the technology being used is limited by a single, ever-important factor: heat. The key to improved performance, increased computer longevity, and lower upkeep costs lies in managing machine temperatures. Previously, this topic was investigated for the world of PCs. In this paper, modifications, upgrades, and available components that improve cooling are discussed in regard to servers and Apple products. Through the use of these methodologies, the aformentioned improve- ments may be achieved. Contents 1 Introduction 1 2 Background 1 3 Servers 2 3.1 Freestanding . 3 3.2 Rack Mount . 3 4 Apple Products 5 4.1 Difficulties . 5 4.2 Mac Desktops . 5 4.2.1 iMac . 6 4.2.2 Mac Pro . 6 4.3 Mac Mini . 7 4.4 Apple TV . 7 4.5 MacBook . 8 5 Business Economics 8 5.1 Servers . 8 5.2 Apple . 9 6 Related Work 9 7 Conclusion 10 1 Introduction freestanding and rack mount servers, as their differences are significant. The topics of \Now this is not the end. It is not even this paper then make a transition to Ap- the beginning of the end. But it is, per- ple products, touching upon the difficulties haps, the end of the beginning." -Sir Win- in improving cooling for Apple machines, as ston Churchill, 1942 well as individual investigations of the iMac, Six months ago, the author completed a Mac Pro, Mac Mini, Apple TV, and Mac- research, analysis, and experimentation pa- Book.
    [Show full text]
  • Motivair Cooling Solutions Report
    Cooling System Considerations for High Density Colocation and Enterprise Data Centers By Rich Whitmore Executive summary The recent advances in computer technology and the growing adoption of high performance CPUs and GPUs are allowing users to achieve new heights in computer analytics including the use of Big Data, Artificial Intelligence, High-Frequency Trading, Oil & Gas research and web scale business models. This rapid rise in use has overtaken most Colocation and Enterprise facilities’ ability to cool the se often-densified server racks on a large scale. While many facilities publish the ability to provide cooling for higher than standard server racks on a watts per square foot basis, many if not all are unable to manage newer computer systems at that density on a large scale. Co location and Enterprise data centers must consider how these new computers will interact within the data center environment, educate themselves on the various solutions available to cool these dense servers and build the infrastructure that can support the latest computer racks being used both today and in the future. Cooling System Considerations for High Density Colocation and Enterprise Data Centers Introduction As the uses for high density computers continues to expand, the requirements for operating these advanced systems has also grown. The drive for higher efficiency data centers is a subject closely tied to a building’s Power Usage Effectiveness (PUE) which is defined as: (Total Facility Energy) / (IT Equipment Energy). High Performance Computing (HPC) clusters and high-density compute racks are consuming power densities of up to 100 kW per rack, sometimes higher, with an estimated average density of 35 kW per rack.
    [Show full text]
  • “Cooling System for Electronics in Computer System- an Overview”
    International Journal of Recent Engineering Research and Development (IJRERD) Volume No. 02 – Issue No. 02, ISSN: 2455-8761 www.ijrerd.com, PP. 01-04 “Cooling system for electronics in computer system- an overview” KunalPardeshi1, P.G Patil2, R.Y.Patil3 1 Master Scholar MechanicalEnineering Department, S.G.D.C.O.E. Jalgaon 2Assistant Professor, Mechanical Enineering Department, S.G.D.C.O.E. Jalgaon 3Head, Mechanical Department, S.G.D.C.O.E. Jalgaon Abstract: During the power management, the inevitable power losses induce heat generation in the power electronics. In this, effective design for the cooling system is essential in terms of safety, reliability, and durability. A liquid cooling system for the power electronics is applied to chill the electrical components below the thermal specifications. Nonetheless, the layout of cooling components is usually designed after the completion of the chassis and power electronics in the automotive applications, thus, only a little freedom is allowed to change the layout. Thus, it is significant and urgent to investigate the cooling performance before finalizing the layout design. In this work, one dimensional and computerized fluid dynamics code is employed to simulate the performance of the cooling system at the early stage of conceptual design. Three different layouts of cooling systems are chosen to compare the ensuing systematic cooling performances. The liquid flow rates, pressure drops, and maximum temperatures are computed by the numerical simulations of the cooling system which comprises the cold plates, liquid pump and heating electronic device. Index Terms: High performance CPUs, heat transfer enhancement, liquid impingement, heat transfer 1.
    [Show full text]
  • Floor Mount & In-Rack Models
    coolant distribution unit Floor Mount & In-Rack Models TM OUR BUSINESS IS COOLING YOURS motivaircorp.com COMPREHENSIVE COOLING FOR YOUR DIGITAL WORLD From Hyperscale to Exascale KEY REASONS A Coolant Distribution Unit (CDU) is designed to control and separate colder facility water supplies TO USE A from the IT cooling infrastructure. It allows you to deploy higher density, load diverse IT equipment in ® a smaller footprint & improve efficiency. MOTIVAIR CDU This action of “decoupling” allows the CDU to accurately monitor and control the flow and temperature of clean, cool fluid to all types of IT cooling systems, including Active and Passive Rear • Isolates a clean water supply Door Heat Exchangers or Liquid-Cooled Computer Systems (Direct-to-Chip or On-Chip). for IT cooling system The CDU maintains a secondary loop water temperature above the dew point in the data center to • Maintains water temperature eliminate the possibility of condensation. above data center dew point eliminating the possibility of condensation • Automatically adjusts water flow and temperature for scale-on-demand IT loads MODELS APPLICATION MCDU-4U 105 kW ChilledDoor® • Offers inherent redundancies MCDU15 310 kW Rack Cooling System & MCDU 25 625kW Liquid-Cooled Computer Systems for maximized uptime MCDU 40 1250kW • Ideal for W1 – W5 cooling systems Custom OEM Solutions • Made in the USA Motivair offers flexible CDU designs for unique liquid cooling applications, including custom OEM solutions. TM OUR BUSINESS IS COOLING YOURS motivaircorp.com HOW IT WORKS The Motivair® Coolant Distribution Unit (CDU) creates an isolated water loop and pumps this through the cooling system DECOUPLE to operate at maximum efficiency.
    [Show full text]
  • A View from the Facility Operations Side on the Water/Air Cooling System of the K Computer
    A View from the Facility Operations Side on the Water/Air Cooling System of the K Computer Jorji Nonaka∗ Keiji Yamamoto Akiyoshi Kuroda HPC Usability Dev. Unit System Operations & Dev. Unit Application Tuning Dev. Unit RIKEN R-CCS RIKEN R-CCS RIKEN R-CCS Kobe, Japan Kobe, Japan Kobe, Japan Toshiyuki Tsukamoto Kazuki Koiso Naohisa Sakamoto Facility Operations & Dev. Unit Grad. School of System Informatics Grad. School of System Informatics RIKEN R-CCS Kobe University Kobe University Kobe, Japan Kobe, Japan Kobe, Japan ABSTRACT ACM Reference Format: Eight years have been passed since the first appearance of the K Jorji Nonaka, Keiji Yamamoto, Akiyoshi Kuroda, Toshiyuki Tsukamoto, computer in the TOP500 list as the most powerful system at that Kazuki Koiso, and Naohisa Sakamoto. 2019. A View from the Facility Op- erations Side on the Water/Air Cooling System of the K Computer. In time. Currently, the count down for the final shutdown has already Proceedings of IEEE/ACM Supercomputing Conference (SC19 Poster). ACM, started, and the preparations for the substitution are also underway. New York, NY, USA, 3 pages. https://doi.org/10.1145/1122445.1122456 The Operations and Computer Technologies Division at the RIKEN R-CCS is responsible for the management and operations of the 1 INTRODUCTION entire Facility, which includes the auxiliary subsystems such as the Almost five years have been passed from the first detailed opera- power supply, and water/air cooling systems. It is worth noting that tion analysis [6], and four years from the detailed hardware failure part of these subsystems will be reused in the next supercomputer analysis [5] of the K computer system.
    [Show full text]
  • ASHRAE Standard 90.1-2010 Equipment Final Rule Technical
    CHAPTER 4. ENERGY USE CHARACTERIZATION TABLE OF CONTENTS 4.1 INTRODUCTION .............................................................................................................. 4-1 4.2 ENERGY USE ANALYSIS BY EQUIPMENT TYPE ..................................................... 4-1 4.2.1 Water-Cooled Air Conditioners .............................................................................. 4-1 4.2.1.1 Water-Cooled Compressor-Condenser Performance .................................. 4-3 4.2.1.2 Supply Water Temperature ......................................................................... 4-5 4.2.1.3 Supply Fan Power ....................................................................................... 4-5 4.2.1.4 Water-Cooled Compressor-Condenser-Only Cooling Coefficient of Performance vs. Energy Efficiency Ratio Relationship ......................................... 4-6 4.2.1.5 Baseline Annual Energy Use Per Ton – Water-Cooled .............................. 4-7 4.2.1.6 Energy Use Estimates for Baseline and Higher Efficiency Water-Cooled Air Conditioner Equipment by Equipment Class. ......................................................... 4-9 4.2.2 Evaporatively Cooled Air Conditioners................................................................ 4-11 4.2.2.1 Baseline Annual Energy Use Per Ton – Evaporatively Cooled ............... 4-12 4.2.2.2 Energy Use Estimates for Baseline and Higher Efficiency Evaporatively Cooled Air Conditioners by Equipment Class ...................................................... 4-13 4.2.3
    [Show full text]
  • Enhanced Cooling of Laptop Computer for Improvement of Processing Performance by Mohammed A
    Global Journal of Computer Science and Technology: H Information & Technology Volume 15 Issue 5 Version 1.0 Year 2015 Type: Double Blind Peer Reviewed International Research Journal Publisher: Global Journals Inc. (USA) Online ISSN: 0975-4172 & Print ISSN: 0975-4350 Enhanced Cooling of Laptop Computer for Improvement of Processing Performance By Mohammed A. Bou-Rabee, Shaharin A. Sulaiman & Wan M. S. W. Mazlan U niversity Teknologi Petronas, Kuwait Abstract- A major problems in the operation of laptop computers is overheating since it can affect the performance and stability, sometimes leading to system crash and hardware fatality. The objective of this work was to study the thermal behavior inside a laptop computer and to test the effectiveness of aproposed cooling method to overcome overheating problem. The proposed cooling system contained a thermoelectric device that reduced the intake air temperature into the laptop internal cooling system. An external exhaust blower, located at the exhaust air outlet of the laptop, was mounted to ensure sufficient air flow rate delivered by the cooling system. To assess the effectiveness of the system, temperatures of critical components in the computer were measured. It was found from the study that, under extreme utilization situation, the temperature of the graphic processing unit could increase to 99°C. The proposed cooling system could bring down the temperature by up to 6°C. Keywords: computer; power electronics; laptop; overheating; cooking; heat dissipation; thermoelectric. GJCST-H Classification: B.5.2 B.7.1 EnhancedCoolingofLaptopCompterforImprovementofProcessingPerformance Strictly as per the compliance and regulations of: © 2015. Mohammed A. Bou-Rabee, Shaharin A. Sulaiman & Wan M.
    [Show full text]
  • Miniature Loop Heat Pipe with Flat Evaporator for Cooling Computer CPU Randeep Singh, Aliakbar Akbarzadeh, Chris Dixon, Mastaka Mochizuki, and Roger R
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by RMIT Research Repository 42 IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, VOL. 30, NO. 1, MARCH 2007 Miniature Loop Heat Pipe With Flat Evaporator for Cooling Computer CPU Randeep Singh, Aliakbar Akbarzadeh, Chris Dixon, Mastaka Mochizuki, and Roger R. Riehl Abstract—This paper presents an experimental investigation Subscripts on a copper miniature loop heat pipe (mLHP) with a flat disk Ambient. shaped evaporator, 30 mm in diameter and 10-mm thick, designed for thermal control of computer microprocessors. Tests were Compensation chamber. conducted with water as the heat transfer fluid. The device was Condenser. capable of transferring a heat load of 70 W through a distance up to 150 mm using 2-mm diameter transport lines. For a range of Evaporator. power applied to the evaporator, the system demonstrated very Junction. reliable startup and was able to achieve steady state without any symptoms of wick dry-out. Unlike cylindrical evaporators, flat Heat pipe. evaporators are easy to attach to the heat source without need of Total. any cylinder-to-plane reducer material at the interface and thus offer very low thermal resistance to the heat acquisition process. Vapor. In the horizontal configuration, under air cooling, the minimum Liquid. value for the mLHP thermal resistance is 0.17 C/W with the corresponding evaporator thermal resistance of 0.06 C/W. It is concluded from the outcomes of the current study that a mLHP I. INTRODUCTION with flat evaporator geometry can be effectively used for the thermal control of electronic equipment including notebooks with limited space and high heat flux chipsets.
    [Show full text]
  • Silent & Fan-Less Mini-PC Using Case for Passive Cooling
    International Conference On Emanations in Modern Technology and Engineering (ICEMTE-2017) ISSN: 2321-8169 Volume: 5 Issue: 3 369 - 374 ____________________________________________________________________________________________________________________ Silent & Fan-Less Mini-PC using Case for Passive Cooling Jasmohan Singh Narula, Siddhivinayak Zaveri, Rohan Chaubey and Dhruv Nagpal Shree L. R. Tiwari College of Engineering, Computer Department Kanakia Road, Kanakia Park, Mira Road East, Mira Bhayandar, Maharashtra 401107, India [email protected], [email protected], [email protected] Abstract- Small form factors personal computers are on the rise as there is a demand for them from users. This document explores the different form factors of personal computers and ways in which Mini-PCs can be improved to provide a better alternative for their bigger counterpart Desktop PCs. The main aim of this document is to explore ideas and try to innovate with the existing as well as new methods, using newer designs and manufacturing techniques for creating better Mini-PCs which can achieve a balance between performance, size, and noise. Originally the concept of Passive Cooling was only used for heat producing components other than CPU, but through our findings it can be a better option for such small factor computers like Mini-PC and their case can be given a secondary purpose other than for aesthetics. Keywords–PC, Desktop, Mini-PC, Heatsink, Benchmarks, Thermal Management & Throttling, Thermal Design Power, Dynamic Frequency Scaling __________________________________________________*****_________________________________________________ I. INTRODUCTION Mini-PCs have come into the picture today by the combination of flexibility of Desktops and portability of With rapid advancement in computer design and Laptop. Based on small, low-power components, they take engineering, PC’s are becoming smaller.
    [Show full text]
  • Development of an Experimental Apparatus for the Testing of Novel Cooling Systems for Processors
    DEVELOPMENT OF AN EXPERIMENTAL APPARATUS FOR THE TESTING OF NOVEL COOLING SYSTEMS FOR PROCESSORS Michael Hinton Master of Engineering Department of Mechanical Engineering McGill University Montr´eal, Qu´ebec August 13, 2017 A thesis submitted to McGill University in partial fulfillment of the requirements of the degree of Master of Engineering ©Michael Hinton, 2017 ii ACKNOWLEDGEMENTS I would like to begin by thanking, most importantly, my supervisor, Professor Laurent Mydlarski. Through his continued support and guidance, I have grown as a scientific re- searcher and achieved my academic goals. I especially owe him a debt of gratitude for his role in bringing the present work to fruition. This research project was conducted in collaboration with Hypertec, a computer hard- ware and services company in the Montr´eal area. Hypertec provided resource support in the form of funding, equipment and personnel. Thank you to Eliot Ahdoot for his role in initiating the project and seeing it through, and a special thank you to Fabrice, Jihad, Gilles, Florian, Noman, and Joseph for all of their technical and procurement advice and support. Furthermore, I would like to voice my appreciation to the providers of financial support for this project. A McGill Engineering Undergradatuate Student Masters Award (MEUSMA) was granted by the McGill Faculty of Engineering. Moreover, I was awarded an Alexander Graham Bell Canada Graduate Scholarship-Master’s (CGS M) by the Natural Sciences and Engineering Research Council of Canada (NSERC), who also supplied an NSERC Engage grant. Lastly, Mitacs funded the project by means of a Mitacs Accelerate award. I would be remiss if I did not also thank my friends and family for their endless support.
    [Show full text]
  • Use of Nanofluids in Computer Cooling Systems: an Application
    ISSN (e): 2250 – 3005 || Volume, 08 || Issue, 07|| July – 2018 || International Journal of Computational Engineering Research (IJCER) Use of Nanofluids in Computer Cooling Systems: An Application Ayusman Nayak1,Atul2,Jagadish Nayak3 1,3Assistant Professor, Department of Mechanical Engineering, Gandhi Institute For Technology (GIFT), Bhubaneswar 2 Assistant Professor, Department of Mechanical Engineering, Gandhi Engineering College, Bhubaneswar Abstract: This paper works on the applications of nano fluid for the cooling of computers and other such devices. Various parameters has been considered. Thermal properties and the effect of using nanofluids on cooling performance of liquid cooling systems were investigated in this research. Keywords: cooling, Nanofluid I. INTRODUCTION In electronic industry, improvement of the thermal performance of coolingsystems together with the reduction of their required surface area has always been a great technical challenge. Research carried out on this subject can be classifiedinto three general approaches: finding the best geometry for cooling devices, decreasing the characteristic length and recently increasing the thermalperformance of the coolant. The latest approach is based on the discovery ofnanofluids. Nanofluids are expected to have a better thermal performance than conventional heat transfer fluids due to the high thermal conductivity of suspendednanoparticles. In recent years there have been several investigations showing enhancement of thermal conductivity of nanofluids.The cooling performance of a water cooling kit with the addition of nanofluids is investigated. A real computer setup with a quad-core processor has been used to determine the effect of use of nanofluid on the cooling system in real practical condition. 1.1 LITERATURE SURVEY The basic ideas regarding the topic was taken from the journal paper Application of nanofluids in computer cooling systems (heat transfer performance ofnanofluids) by M.
    [Show full text]