Experiment 2: Instrumentation and Oscilloscope Introduction
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
MXG X-Series Signal Generators N5183B Microwave Analog 9 Khz to 13, 20, 31.8, Or 40 Ghz
MXG X-Series Signal Generators N5183B Microwave Analog 9 kHz to 13, 20, 31.8, or 40 GHz Find us at www.keysight.com Page 1 Definitions Specification (spec): Specifications represent warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range of 0 to 55 °C, unless otherwise stated, and after a 45 minutes warm-up period. The specifications include measurement uncertainty. Data represented in this document are specifications unless otherwise noted. Typical (typ): Typical (typ) describes additional product performance information. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level at room temperature (approximately 25 °C). Typical performance does not include measurement uncertainty. Nominal (nom) or measured (meas): Nominal (nom) or measured (meas) describes a performance attribute that is by design or measured during the design phase for the purpose of communicating sampled, mean, or average performance, such as the 50-ohm connector or amplitude drift vs. time. This data is not warranted and is measured at room temperature (approximately 25 °C). Find us at www.keysight.com Page 2 Frequency Specifications Range Frequency range Option 513 9 kHz to 13 GHz Option 520 9 kHz to 20 GHz Option 532 9 kHz to 31.8 GHz Option 540 9 kHz to 40 GHz Resolution 0.001 Hz Phase offset Adjustable in nominal 0.1° increments Frequency switching speed 1 () = typical Standard Option UNZ 2, 4 Option UZ2 3, 4 CW mode SCPI mode (≤ 5 ms) ≤ 1.15 ms (≤ 750 μs) < 1.65 ms (1 ms) List/step sweep mode (≤ 5 ms) ≤ 900 μs (≤ 600 μs) < 1.4 ms (850 μs) 1. -
1806-A Electronic Voltmeter, Manual
OPERATING INSTRUCTIONS TYPE 1806-A ELECTRONIC VOLTMETER Form 1806-0100-C March, 1967 Copyright 1963 General Radio Company West Concord, Massachusetts, USA GENERAL RADIO COMPANY WEST CONCORD, MASSACHUSETTS, USA SPECIFICATIONS DC VO~TMETER Voltage Ro.nge: Four ranges, 1.5, 15, 150, and 1500 V, full scale, positive or negative. Minimum reading is 0.005 V. Input Resistance: 100 M!'l, ±5%; also "open grid" on all but the 1500-V range. Grid current is less than I0-10 A. Accuracy: ±2% of indicated value from one-tenth of full scale to full scale; ±0.2% of full scale from one-tenth of full scale to zero. Scale is logarithmic from one-tenth of full scale to full scale, permitting constant-percentage readability over that range. AC VOLTMETER Voltage Range: Four ranges, 1.5, 15, 150, and 1500 V, full scale. Minimum reading on most sensitive range is 0.1 V. Input Impedance: Probe, approximately 25 Mn in parallel with 2 pF; with TYPE 1806-P2 Range Multiplier, 2500 M!'l in parallel with 2 pF; at binding post on panel, 25 Mn in parallel with 30 pF. Accuracy: At 400 c/ s, ±2% of indicated value from 1.5 V to 1500 V; ±3% of indicated value from 0.1 V to 1.5 V. Waveform Error: On the higher ac-voltage ranges, the instrument operates as a peak voltmeter, calibrated to read rms values of a sine wave or 0.707 of the peak value of a complex wave. On distorted waveforms the percentage deviation of the reading from the rms value may be as large as the percentage of harmonics present. -
Digital Power Analyzer Model 4301
Model 4301 Modular Power Analyzer An All-Purpose Digital Measurement Instrument for Power Conversion Device Testing Model 4301 Modular Power Analyzer 0.1% reading and 0.1% range accuracy Up to 16 Power Analyzer modules in a single chassis 25 standard AC and DC, static and dynamic measurements Dual DSPs with 1MHz sampling rate 6 voltage and current ranges plus auto-ranging for increased accuracy Peak-Peak noise measurements, 10Hz - 20MHz Two Digital Logic Inputs per module Chassis communications through a PC/LAN with LabVIEW and IVI- compliant drivers Applications The Model 4301 Power Analyzer is primarily designed for use in automated test environments configured for simultaneous testing of multiple power conversion UUTs. The Analyzer’s advantage in this application are speed, size and measurement performance. Speed is achieved through having Model 4301 a single instrument capable of making a wide range of measurements dedicated to each test channel. Test system size is minimized through the modular single-card design, 16 of which can be fitted into a multi-instrument chassis. Measurement performance is achieved by deriving an extensive number of high accuracy measurements from a digitized waveform. This last capability is particularly useful where input as well as output measurements are necessary to precisely calculate UUT efficiency. 3 Instruments in 1 Through Waveform Digitization The 4301 Analyzer can be thought of as functionality equivalent to three instruments: a power meter, a multimeter and an oscilloscope. This capability is achieved through the Analyzer’s state-of-the-art, dual A/D converters with a 1MHz sampling rate that provides the data to make practically any power- conversion-related static or dynamic measurement provided by the three types of instruments above. -
The Accuracy Comparison of Oscilloscope and Voltmeter Utilizated in Getting Dielectric Constant Values
Proceeding The 1st IBSC: Towards The Extended Use Of Basic Science For Enhancing Health, Environment, Energy And Biotechnology 211 ISBN: 978-602-60569-5-5 The Accuracy Comparison of Oscilloscope and Voltmeter Utilizated in Getting Dielectric Constant Values Bowo Eko Cahyono1, Misto1, Rofiatun1 1 Physics Departement of MIPA Faculty, Jember University, Jember – Indonesia, e-mail: [email protected] Abstract— Parallel plate capacitor is widely used as a sensor for many purposes. Researches which have used parallel plate capacitor were investigation of dielectric properties of soil in various temperature [1], characterization if cement’s dielectric [2], and measuring the dielectric constant of material in various thickness [3]. In the investigation the changing of dielectric constant, indirect method can be applied to get the dielectric constant number by measuring the voltage of input and output of the utilized circuit [4]. Oscilloscope is able to measure the voltage value although the common tool for that measurement is voltmeter. This research aims to investigate the accuracy of voltage measurement by using oscilloscope and voltmeter which leads to the accuracy of values of dielectric constant. The experiment is carried out by an electric circuit consisting of ceramic capacitor and sensor of parallel plate capacitor, function generator as a current source, oscilloscope, and voltmeters. Sensor of parallel plate capacitor is filled up with cooking oil in various concentrations, and the output voltage of the circuit is measured by using oscilloscope and also voltmeter as well. The resulted voltage values are then applied to the equation to get dielectric constant values. Finally the plot is made for dielectric constant values along the changing of cooking oil concentration. -
Electrical Multimeter MMW02
Motors | Automation | Energy | Transmission & Distribution | Coatings Electrical Multimeter MMW02 Installation & Operation Manual Installation & Operation Manual Serie: MMW02 Language: English Summary SUMMARY 1 INTRODUCTION 10 1.1 CALIBRATION EXPIRY TERM ............................................................................................................10 1.2 CONFORMITY DECLARATION .............................................................................................................. 10 1.2.1 Reference Standards ................................................................................................................10 1.3 SAFETY INFORMATION .....................................................................................................................10 1.3.1 Dangers .....................................................................................................................................11 1.3.2 Attention ....................................................................................................................................11 1.4 RECEIVING THE PRODUCT ...............................................................................................................11 1.5 TECHNICAL SUPPORT AND ASSISTANCE ......................................................................................11 2 OVERVIEW 13 2.1 MEASURE OF BASIC QUANTITIES .................................................................................................13 2.2 THD CALCULATION ...........................................................................................................................13 -
An Oscilloscope Correction Method for Vector-Corrected RF Measurements
This article has been accepted for inclusion in a future issue of this journal. Content is final as presented, with the exception of pagination. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 1 An Oscilloscope Correction Method for Vector-Corrected RF Measurements Sebastian Gustafsson, Student Member, IEEE, Mattias Thorsell, Member, IEEE, Jörgen Stenarson, Member, IEEE, and Christian Fager, Member, IEEE Abstract— The transfer characteristics of the RF front-end circuit components. As these errors must be compensated for circuitry of a real-time oscilloscope (RTO) are not only frequency to achieve accurate signal sampling [4], several correction dependent and nonlinear with signal amplitude but also depen- techniques have been introduced [5], [6]. Other correction dent on the voltage range setting of the oscilloscope. A correction table in the frequency domain is proposed to account for the techniques have also been introduced [7]–[12], but they are additional gain and delay introduced when switching between only valid for sampling oscilloscopes. Previous research different voltage ranges. The table was extracted from the has focused on correction techniques for a certain set of measured data in which a continuous-wave signal source was instrument settings, e.g., a particular voltage range. Hence, connected to the oscilloscope ports, whereas the input power, the changing the settings would make the correction invalid. frequency, and voltage ranges were varied. The importance of the corrections is demonstrated by its use in an RTO-based two-port However, changing the range is desirable in some applications, vector-corrected measurement system. Measurements from the to fully utilize the voltage range of the ADC. -
Equivalent Resistance
Equivalent Resistance Consider a circuit connected to a current source and a voltmeter as shown in Figure 1. The input to this circuit is the current of the current source and the output is the voltage measured by the voltmeter. Figure 1 Measuring the equivalent resistance of Circuit R. When “Circuit R” consists entirely of resistors, the output of this circuit is proportional to the input. Let’s denote the constant of proportionality as Req. Then VRIoeq= i (1) This is the same equation that we would get by applying Ohm’s law in Figure 2. Figure 2 Interpreting the equivalent circuit. Apparently Circuit R in Figure 1 acts like the single resistor Req in Figure 2. (This observation explains our choice of Req as the name of the constant of proportionality in Equation 1.) The constant Req is called “the equivalent resistance of circuit R as seen looking into the terminals a- b”. This is frequently shortened to “the equivalent resistance of Circuit R” or “the resistance seen looking into a-b”. In some contexts, Req is called the input resistance, the output resistance or the Thevenin resistance (more on this later). Figure 3a illustrates a notation that is sometimes used to indicate Req. This notion indicates that Circuit R is equivalent to a single resistor as shown in Figure 3b. Figure 3 (a) A notion indicating the equivalent resistance and (b) the interpretation of that notation. Figure 1 shows how to calculate or measure the equivalent resistance. We apply a current input, Ii, measure the resulting voltage Vo, and calculate Vo Req = (1) Ii The equivalent resistance can also be measured using and ohmmeter as shown in Figure 4. -
Keysight 53147A/148A/149A Microwave Frequency Counter/Power Meter/DVM
Keysight 53147A/148A/149A Microwave Frequency Counter/Power Meter/DVM Assembly Level Service Guide Notices U.S. Government Rights Warranty The Software is “commercial computer THE MATERIAL CONTAINED IN THIS Copyright Notice software,” as defined by Federal Acqui- DOCUMENT IS PROVIDED “AS IS,” sition Regulation (“FAR”) 2.101. Pursu- AND IS SUBJECT TO BEING © Keysight Technologies 2001 - 2017 ant to FAR 12.212 and 27.405-3 and CHANGED, WITHOUT NOTICE, IN No part of this manual may be repro- Department of Defense FAR Supple- FUTURE EDITIONS. FURTHER, TO THE duced in any form or by any means ment (“DFARS”) 227.7202, the U.S. MAXIMUM EXTENT PERMITTED BY (including electronic storage and government acquires commercial com- APPLICABLE LAW, KEYSIGHT DIS- retrieval or translation into a foreign puter software under the same terms CLAIMS ALL WARRANTIES, EITHER language) without prior agreement and by which the software is customarily EXPRESS OR IMPLIED, WITH REGARD written consent from Keysight Technol- provided to the public. Accordingly, TO THIS MANUAL AND ANY INFORMA- ogies as governed by United States and Keysight provides the Software to U.S. TION CONTAINED HEREIN, INCLUD- international copyright laws. government customers under its stan- ING BUT NOT LIMITED TO THE dard commercial license, which is IMPLIED WARRANTIES OF MER- Manual Part Number embodied in its End User License CHANTABILITY AND FITNESS FOR A 53147-90010 Agreement (EULA), a copy of which can PARTICULAR PURPOSE. KEYSIGHT be found at http://www.keysight.com/ SHALL NOT BE LIABLE FOR ERRORS Edition find/sweula. The license set forth in the OR FOR INCIDENTAL OR CONSE- Edition 3, November 1, 2017 EULA represents the exclusive authority QUENTIAL DAMAGES IN CONNECTION by which the U.S. -
Power Meter Ml2430a Series Maintenance Manual
Maintenance Manual POWER METER ML2430A SERIES MAINTENANCE MANUAL Anritsu Company Part Number: 10585-00003 490 Jarvis Drive Revision: J Morgan Hill, CA 95037-2809 Published: February 2021 USA Copyright 2021 Anritsu Company Notes On Export Management This product and its manuals may require an Export License or approval by the government of the product country of origin for re-export from your country. Before you export this product or any of its manuals, please contact Anritsu Company to confirm whether or not these items are export-controlled.When disposing of export-controlled items, the products and manuals need to be broken or shredded to such a degree that they cannot be unlawfully used for military purposes. NOTICE Anritsu Company has prepared this manual for use by Anritsu Company personnel and customers as a guide for the proper installation, operation and maintenance of Anritsu Company equipment and computer programs. The drawings, specifications, and information contained herein are the property of Anritsu Company, and any unauthorized use or disclosure of these drawings, specifications, and information is prohibited; they shall not be reproduced, copied, or used in whole or in part as the basis for manufacture or sale of the equipment or software programs without the prior written consent of Anritsu Company. UPDATES Updates, if any, can be downloaded from the Documents area of the Anritsu Website at: http://www.anritsu.com For the latest service and sales contact information in your area, please visit: https://www.anritsu.com/Contact-US/ Table of Contents Chapter 1—General Information 1-1 Scope Of This Manual . -
Future of Vector Network Analysis Dylan Williams and Nate Orloff Integrated Circuits Drive Wireless Communications
Future of Vector Network Analysis Dylan Williams and Nate Orloff Integrated Circuits Drive Wireless Communications Application Frequency (GHz) 10 30 100 300 1000 100 10 Transit Frequency (GHz) Frequency Transit 1990 1995 2000 2005 2010 2015 2020 Year We Cannot Take the Integrated Circuit for Granted at mmWaves 2 Next 15 Years of Wireless Manufacturing by Country The United States still dominates mmWave manufacturing Enables $12.3T in Total Economic Growth (2020-2035) Communication Providers Want Speed of Fiber on Your Phone Millimeter-Waves are the Next Wireless Frontier Measurements and Calibrations Matter at mmWaves Before Calibration 64 QAM at 44 GHz After Calibration mmWave Measurement Challenge of our Era Not a Single RF Connector! On-Wafer IC and System-Level Test OTA System-Level Test Transistor models IC Test System-Level Test End-to-End Verification On-Wafer Connectorized Free-Space Goals for Vector Network Analysis in CTL Project Calibration Reference Planes On-Wafer and to OTA Test On-Wafer Measurements • Innovations in Calibration • Support Device Models to System-Level Test • State-Of-The-Art Instruments for US mmWave NR Manufacturers Vector Network Analysis • Platform for Traceable System-Level Tests Across CTL • Close the Connector-Less Gap mmWave Design Extremely Complex Accurate measurements are a must 80 80 GHz GHz 160 ~ GHz 240 GHz • Highly nonlinear operating states required for efficiency • Characterize, capture, control and reuse harmonics • Must maintain linearity On-Wafer Measurement the Only Way to Test ICs Yesterday -
P50xxa Streamline Series Vector Network Analyzer 2/4-Port up to 53 Ghz
P50xxA Streamline Series Vector Network Analyzer 2/4-port Up to 53 GHz. 2/4/6-port Up to 20 GHz Compact Form. Zero Compromise. P5000A/P5020A 9 kHz to 4.5 GHz P5001A/P5021A 9 kHz to 6.5 GHz P5002A/P5022A 9 kHz to 9 GHz P5003A/P5023A 9 kHz to 14 GHz P5004A/P5024A 9 kHz to 20 GHz P5005A/P5025A 100 kHz to 26.5 GHz P5006A/P5026A 100 kHz to 32 GHz P5007A/P5027A 100 kHz to 44 GHz P5008A/P5028A 100 kHz to 53 GHz Find us at www.keysight.com Page 1 Keysight P500xA and P502xA Streamline Series VNA The freedom of portable network analysis doesn’t have to mean a compromise in performance. The P50xxA Series brings high-end performance and flexibility to the portable Keysight Streamline Series. Gain confidence in your measurements with best-in-class performance offering fast, reliable, and repeatable results. Explore the complete characterization of your devices with a rich portfolio of software applications that transform the compact network analyzer into a complete RF measurement solution. The P50xxA Series, a member of Keysight’s Streamline Series offers the performance required for testing passive components, amplifiers, mixers or frequency converters. The vector network analyzer (VNA) provides best-in-class key specifications such as dynamic range, measurement speed, trace noise and temperature stability. Choose from 2- or 4-port models up to 53 GHz, or 2-, 4- or 6-port models up to 20 GHz. The VNA is packaged in a compact chassis and controlled by an external computer with powerful data processing capabilities and functionalities. -
10 Factors in Choosing a Basic Oscilloscope 10 Factors in Choosing a Basic Oscilloscope Contents Intro 1 2 3 4 5 6 7 8 9 10 11 Contact 2
10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE 10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE CONTENTS INTRO 1 2 3 4 5 6 7 8 9 10 11 CONTACT 2 10 Factors in Choosing a Basic Oscilloscope There are several ways to navigate this interactive PDF document: Click on the table of contents (page 3) Basic oscilloscopes are used as windows into signals for troubleshooting Use the navigation at the top of each page to jump circuits or checking signal quality. They generally come with bandwidths to sections or use the page forward/back arrows from around 50 MHz to 200 MHz and are found in almost every design lab, Use the arrow keys on your keyboard education lab, service center and manufacturing cell. Use the scroll wheel on your mouse Whether you buy a new scope every month or every five years, this guide will Left click to move to the next page, right click to move to the previous page (in full-screen mode only) give you a quick overview of the key factors that determine the suitability of a Click on the icon ß to enlarge the image. basic oscilloscope to the job at hand. The digital storage oscilloscope Oscilloscopes are the basic tool for anyone designing, manufacturing or repairing electronic equipment. A digital storage oscilloscope (DSO, on which this guide concentrates) acquires and stores waveforms. The waveforms show a signal’s voltage and frequency, whether the signal is distorted, timing between signals, how much of a signal is noise, and much, much more. 10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE CONTENTS INTRO 1 2 3 4 5 6 7 8 9 10 11