Principles of Evaporative Cooling System
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Electriq AC60E EVAPORATIVE COOLER with HUMIDIFIER User
USER MANUAL EVAPORATIVE COOLER WITH HUMIDIFIER AC60E Thank you for choosing electriQ Please read this user manual before using this innovative Air Cooler and keep it safe for future reference. Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND OPERATION 4 PARTS LIST AND INSTALLATION 5 CONTROL PANEL AND SETTINGS 6 REMOTE CONTROL 7 CLEANING AND MAINTENANCE 7 TROUBLE SHOOTING 8 APPENDIX 8 Page 2 of 9 SAFETY INSTRUCTIONS IMPORTANT! Carefully read the instructions before operating the unit This appliance is for indoor use only. Rating: This unit must only be connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. This air cooler has been tested and is safe to use. However, as with any electrical appliance - use it with care. Disconnect the appliance from the power socket before changing filters, dismantling, assembling or cleaning. Avoid touching any moving parts within the appliance. Never insert fingers, pencils or any other objects though the guard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. -
Solar Thermal Dehydrating Plant for Agricultural Products Installed in Zacatecas, México
WEENTECH Proceedings in Energy 5 (2019) 01-19 Page | 1 4th International Conference on Energy, Environment and Economics, ICEEE2019, 20-22 August 2019, Edinburgh Conference Centre, Heriot-Watt University, Edinburgh, EH14 4AS, United Kingdom Solar thermal dehydrating plant for agricultural products installed in Zacatecas, México O. García-Valladares*, I. Pilatowsky-Figueroa, N. Ortiz-Rodríguez, C. Menchaca-Valdez Instituto de Energías Renovables, Universidad Nacional Autónoma de México, privada Xochicalco s/n, centro, CP 62580, Temixco, Morelos, México. *Corresponding author’s mail: [email protected] Abstract This paper presents a hybrid thermo-solar plant for the dehydration of foods, built in Zacatecas, Mexico. The plant is integrated by a semi- continuous drying chamber with a capacity of up to 2 700 kg of fresh product. The thermal energy required for the drying process is provided by two solar powered thermal systems: an air heating system with 48 collectors (111.1 m2) and a water heating system with 40 solar water heaters (92.4 m2), a thermal insulated storage tank, and a fin and tube heat exchanger. The plant also has a fossil energy backup system (LPG) to heat air. The monitoring system measures and records 55 process variables (temperature, relative humidity, water pressure, solar irradiance, air velocity, volumetric and mass flow rates). Experimental results obtained with the solar air heaters and water collectors are reported. The average efficiency of the solar air heaters field was ≈45% with a maximum increase of the air temperature of 40.8 °C and for the water solar collectors field the average efficiency was ≈50% and the water in the storage tank reaches 89.6 °C in two days of operation. -
Evaporative Cooler Parts Accessories
COOLER PUMPS DIAL CTN CTN MODEL CFM /GPH* VOLTS COLOR APPROVAL** P/N QTY WT RESIDENTIAL CONCENTRIC UL Classified Flame Retardant Motor Housing Heavy Duty Motor Auto Reset Thermal Overload Grounded 3 Prong Plug Low Level Pump 1150 UL5500 Premium Pump 5,500 / 240 115V Black UL/UЯ 12 24.5 1175 UL7500 Premium Pump 7,500 / 360 115V Blue UL/UЯ 12 27.9 1195 UL11000 Premium Pump 11,000 / 420 115V Green UL/UЯ 12 32.5 1279 UL7500-2 Premium Pump 7,500 / 360 230V Orange/Black UL/UЯ 6 14.1 1286 UL11000-2 Premium Pump 11,000 / 420 230V Orange/Black UL/UЯ 6 15.4 COMMERCIAL CONCENTRIC UL Classified & City of L.A. Approved Molded 3 Prong Plug Low Level Operation Auto Reset Thermal Overload Grounded Round SJT Power Cord Low Level Splash Protection Flame Retardant Motor Housing Extra Heavy Duty Motor 1414 UL7500LA Pump 7,500 / 375 115V Black UL/UЯ/ COLA 12 31.5 1424 UL11000LA Pump 11,000 / 440 115V Black UL/UЯ/ COLA 12 35.6 1428 UL7500-2LA Pump 7,500 / 375 230V Orange/Black UL/UЯ/ COLA 6 15.2 1429 UL11000-2LA Pump 11,000 / 440 230V Orange/Black UL/UЯ/ COLA 6 16.5 INDUSTRIAL CONCENTRIC Same features as Commercial Pumps 6 Ft Grounded Round SJT Power Cord Requires 5/8 Or 3/4 Inch I.D.Pump Hose 1387 UL15000LA Pump 12 to 21,000 / 505 115V Black UL/UЯ/ COLA 6 17.4 1400 UL25000LA Pump 15 to 25,000 / 580 115V Black UL/UЯ/ COLA 6 17.3 1396 UL15000-2LA Pump 12 to 21,000 / 505 230V Orange/Black UL/UЯ/ COLA 6 17.6 1402 UL25000-2LA Pump 15 to 25,000 / 580 230V Orange/Black UL/UЯ/ COLA 6 16.3 REPLACEMENT FOR MASTERCOOL®/ARCTIC CIRCLE® Replacement Pumps for Mastercool® (using 8” and 12” Media) and Arctic Circle® Coolers UL Classified Exceeds OEM Pump Performance and Longevity Includes Mesh Basket and Mounting Bracket 1442 MC8500UL Pump 4 to 8,500 / 360 115V Tan UL/UЯ 6 14.0 1443 MC8500-2UL Pump 4 to 8,500 / 360 230V Orange/Black UL/UЯ 6 14.5 *Gallons per hour flow rate at 1 foot head height. -
Projected Benefits of New Residential Evaporative Cooling Systems: Progress Report #2
Research Toward Zero Energy Homes October 2006 • NREL/TP-550-39342 Projected Benefits of New Residential Evaporative Cooling Systems: Progress Report #2 Chuck Kutscher and Mark Eastment National Renewable Energy Laboratory Golden, Colorado Ed Hancock Mountain Energy Partnership Boulder, Colorado Paul Reeves Partnership for Resource Conservation Golden, Colorado ENT OF TM EN R E U.S. Department of Energy A R P G E Y D U A Energy Efficiency and Renewable Energy N C I I Building Technologies Program T R E D E M ST A Bringing you a prosperous future where energy is clean, abundant, reliable, and affordable ATES OF Projected Benefits of New Technical Report NREL/TP-550-39342 Residential Evaporative Cooling October 2006 Systems: Progress Report #2 C. Kutscher and M. Eastment National Renewable Energy Laboratory Golden, Colorado E. Hancock Mountain Energy Partnership Boulder, Colorado P. Reeves Partnership for Resource Conservation Golden, Colorado Prepared under Task No.BET6.8004 National Renewable Energy Laboratory 1617 Cole Boulevard, Golden, Colorado 80401-3393 303-275-3000 • www.nrel.gov Operated for the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy by Midwest Research Institute • Battelle Contract No. DE-AC36-99-GO10337 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. -
Instruction Manual Evaporative Air Cooler
Instruction Manual Evaporative Air Cooler It is important that you read these Model No. SF-610 instructions before using your new cooler and we strongly recommend that you keep in a safe place for future reference. CONTENTS A. PRODUCT INTRODUCTION ………………………………………2 B. BRIEF INTRODUCTION OF FEATURES ………………………….2 C. CONTROL PANEL AND PARTS IDENTIFICATION ………………3 D. OPERATING INSTRUCTIONS AND FUNCTIONS ……………….4 E. CARE AND MAINTENANCE …………………………………………6 F. CAUTION ……………………………………………………………….7 G. TECHNICAL PARAMETER …………………………………………8 DEFECTIVE NOTICE …………………………………………………8 WARRANTY ……………………………………………………………9 1 A、PRODUCT INTRODUCTION The Evaporative Air Cooler is capable of providing various types of airflows: quiet and soft air like the spring breeze; fresh air simulating the Coastal breeze; cool, damp air like after a rainfall. The different type of airflows will accommodate your needs to provide a comfortable environment and reduce the heat of summer. The humidifying function will help keep your skin in good condition. The Ionizer feature cleans the air for a pure and clean breathing space. Thank you for purchasing SPT Evaporative Air Cooler. To have an in-depth understanding of the product and to ensure its proper usage, please read this instructions manual thoroughly, especially the relevant information marked Warning and Caution. B、BRIEF INTRODUCTION OF FEATURES 1. High quality computer-controlled system. 2. Mechanical and full function remote control operation. 3. Features humidifier, air filter and Ionizer. 4. The composition of filter, water curtain and ionizer produces fresher air. 5. Supplies moisture to the environment in dry climates. 6. 0.5 to 7.5-hour timer. 7. Ice compartment for extra cooling. 8. Oxygen Bar with Negative Ions: Negative ions have the effect of cleaning the air, providing you a clean healthy surrounding. -
Centrifugal Fans – IM-995
IM-995 Centrifugal Fans April 2020 Installation, Operation & Maintenance Manual REVIEW AMCA PUBLICATION 410 PRIOR TO INSTALLATION This manual has been prepared to guide the users of industrial centrifugal fans in the proper installation, operation and maintenance procedures to ensure maximum equipment life with trouble-free operation. For safe installation, startup and operational life of this equipment, it is important that all involved with the equipment be well versed in proper fan safety practices and read this manual. It is the user’s responsibility to make sure that all requirements of good safety practices and any applicable safety codes are strictly adhered to. Because of the wide variety of equipment covered in this manual, the instructions given here are general in nature. Additional product and engineering information is available at www.tcf.com. SAFETY NOTICE Refer to the safety section(s) in this manual prior to installing or servicing the fan. The most current version of this installation and maintenance manual can be found on our website at www.tcf.com/resources/im-manuals. Table of Contents Overview of Centrifugal Fan Arrangements ............................. 2 Motor Maintenance .................................................................. 16 Exploded Views ...........................................................................3 Drive Maintenance .................................................................... 16 Impeller Nomenclature ..............................................................3 Fan Bearing -
Experimental Measurements of VOC and Radon in Two Romanian Classrooms
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 85 (2016) 288 – 294 Sustainable Solutions for Energy and Environment, EENVIRO - YRC 2015, 18-20 November 2015, Bucharest, Romania Experimental measurements of VOC and Radon in two Romanian classrooms Marian – Andrei Istratea*, Tiberiu Catalinaa, Alexandra Cucosb, Tiberius Dicub aFaculty of Engineering for Building Services, Technical University of Civil Engineering Bucharest, 66, Pache Protopopescu Blvd. Bucharest, 021414, Romania bFaculty of Environmental Science and Engineering, Babes-Bolyai University, 30 Fântânele Street, RO-400294, Cluj-Napoca, România Abstract The present study reports by experimental measurements the levels of volatile organic compounds (VOC) and radon concentrations in two high school classrooms. The difference between the two classrooms abbreviated as S7 and S8 is the presence of a mechanical ventilation system in one of them (S8). The topic is of high importance as the indoor air quality (IAQ) can affect the health and learning performance of the pupils. VOC and RADON have a substantial weight of IAQ and a study of theirs level can help us to better understand at what levels the children are exposed daily. The two mentioned classroom have suffered recently a massive renovation. The classroom with the ventilation system was mounted with variable flow of fresh air, while the other one relies only on natural ventilation by opening the windows. In S8 several test were done for different fresh air ventilation rates. The conclusions were that in the classroom S7 there were measured high levels of VOC and radon, higher than the maximum admissible which is a serious problem. On the other hand, in the classroom S8 for all the different air rates the values were very low, thus creating a healthy and comfortable environment for the learning process. -
System Design Recommendations 1
June.2012 TECHNICAL MANUAL FOR NORTH AMERICA Models Lossnay Unit LGH-F300RX5-E LGH-F470RX5-E LGH-F600RX5-E LGH-F1200RX5-E Lossnay Remote Controller PZ-60DR-E PZ-41SLB-E PZ-52SF-E Y11-001 Jun.2012 <MEE> June.2012 TECHNICAL MANUAL FOR NORTH AMERICA Models Lossnay Unit LGH-F300RX5-E LGH-F470RX5-E LGH-F600RX5-E LGH-F1200RX5-E Lossnay Remote Controller PZ-60DR-E PZ-41SLB-E PZ-52SF-E Y11-001 Jun.2012 <MEE> CONTENTS Lossnay Unit CHAPTER 1 Ventilation for Healthy Living 1. Necessity of Ventilation .................................................................................................................................... U-2 2. Ventilation Standards ....................................................................................................................................... U-3 3. Ventilation Method ............................................................................................................................................ U-4 4. Ventilation Performance .................................................................................................................................... U-7 5. Ventilation Load................................................................................................................................................. U-9 CHAPTER 2 Lossnay Construction and Technology 1. Construction and Features .............................................................................................................................. U-16 2. Lossnay Core Construction and Technology .................................................................................................... -
Modern Evaporative Coolers Not All Evaporative Coolers Are Created Equal
Modern Evaporative Coolers Not all evaporative coolers are created equal. Modern machines operate more efficiently and with much less fuss than the old swamp coolers did. ADOBE ADOBE Here is an inside view (left) and an outside view (right) of a modern evaporative cooler by Adobe. by Larry Kinney dampers, also known as up ducts, in the fer the better comfort and fresh, clean ceilings of rooms on the top story. The air our systems give them. The $300 we ave Emmitt owns Direct Drive process is controlled by a multifunction save them on their utility bill each sum- Service, a company in Colorado thermostat that has the smarts to throttle mer just pays for a barbeque with 50 of Dthat specializes in efficient low- back the fan speed when the setpoint their closest friends.” mass boilers—and high-efficiency evap- temperature is about to be met, rinses Emmitt’s retrofit business is also doing orative coolers. We’re not talking swamp out the reservoir to keep water and air quite well. Colorado homeowners who coolers on the roof of a mobile home; clean, and partially automates much of have never had cooling systems generally Emmitt’s staff install coolers in the attics the end-of-season maintenance. tend to install conventional A/C of large, site-built homes. The coolers “We install modern evaporative systems—as do those who are pull in air from large gable vents, cool it cooler systems in new homes that cost disenchanted with their old swamp cool- by 30°F or so, and distribute it via several $2 million,”reports Emmitt. -
Fanpedia by Twin City Fan Twin City Fan ©2021
FanPedia by twin city fan Twin City Fan ©2021 tcf.com Twin City Fan Fan Basics Fan Types ......................................................................................................................................................................... 4-8 Exploded Views ............................................................................................................................................................. 9-19 Fan Arrangements ....................................................................................................................................................... 20-29 Impeller Orientation ......................................................................................................................................................... 30 Impeller Types ............................................................................................................................................................. 31-34 Impellers Overview...................................................................................................................................................... 35-36 Impellers: Airflow & Rotation ...................................................................................................................................... 37-43 Hub Types .................................................................................................................................................................... 44-45 Discharges & Impeller Rotation .................................................................................................................................. -
2,900 Cfm 3 Speed Evaporative Cooler
Operating Instructions and Parts Manual Please read and save these instructions. Read through this owner’s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure to comply with instructions could result in personal injury and/or damage to product or property. Please retain instructions for future reference. AZ39MA1 2,900 CFM 3 SPEED AZ39MB1 EVAPORATIVE COOLER FOR CUSTOMER SERVICE Technical Question? [email protected] UNPACKING After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing, or damaged parts. If any damage is observed, a shipping damage claim must be filed with the carrier. Do not use the OEMTOOLS® 3 Speed Evaporative Cooler if broken, bent, cracked or damaged parts (including labels) are noted. Any evaporative cooler that appears damaged in any way, operates abnormally or is missing parts should be removed from service immediately. If you suspect that the evaporative cooler was subjected to shock load (a load that was dropped suddenly, unexpectedly, etc.) immediately discontinue use until it has been checked by a factory authorized service center. WARNING The following safety information is provided as a guideline to help you operate your 3 Speed Evaporative Cooler under the safest possible conditions. Any tool or piece of equipment can be potentially dangerous to use when safety or safe handling instructions are not known or not followed. The following safety instructions are to provide the user with the information necessary for safe use and operation. Please read and retain these instructions for the continued safe use of your tool. -
Multistaged Indirect Evaporative Cooler Evaluation
Prepared for the U.S. General Services Administration By National Renewable Energy Laboratory February 2014 Multistaged Indirect Evaporative Cooler Evaluation Jesse Dean Ian Metzger The Green Proving Ground program leverages GSA’s real estate portfolio to evaluate innovative sustainable building technologies and practices. Findings are used to support the development of GSA performance specifications and inform decision-making within GSA, other federal agencies, and the real estate industry. The program aims to drive innovation in environmental performance in federal buildings and help lead market transformation through deployment of new technologies. Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor the National Renewable Energy Laboratory, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by its trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or the National Renewable Energy Laboratory. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof or the National Renewable Energy Laboratory. The work described in this report was funded by the U.S. General Services Administration under Contract No.