Emulex Lpe31002

Total Page:16

File Type:pdf, Size:1020Kb

Emulex Lpe31002 Product Brief Emulex® Gen 6 Fibre Channel HBAs LPe31000/LPe32000-Series for Cisco UCS C-Series and MDS 9000 Product Family Faster Flash. Better Accelerate Virtualization. Lossless The unique Emulex Dynamic Networking. Multi-core Architecture delivers unparalleled performance and The Emulex Gen 6 (16/32Gb) more efficient port utilization than Fibre Channel (FC) Host Bus other HBAs by applying all ASIC Adapters (HBAs) by Broadcom resources to any port that needs it. are designed to address the demanding performance, reliability Compared to the previous Faster Flash and management requirements of generation, Emulex Gen 6 HBAs • Completes data warehousing modern networked storage systems deliver 2x greater bandwidth—up 1 transactions in 1/4 of the time that utilize high performance and to 12,800MBps (2 ports 32G, full • Meet the massive bandwidth low latency solid state storage duplex), less than half the latency, requirements of flash storage arrays drives for caching and persistent and support an industry-leading with up to 32GFC throughput storage as well as hard disk drive 1.6 million IOPS on a single port, • Maximize the performance of arrays. ensuring SLAs are met. Emulex flash-based systems by prioritizing mission-critical traffic in congested Gen 6 HBAs are an excellent networks with the exclusive Fibre Channel is the gold standard choice for database applications ExpressLane feature for network storage connectivity in as recent TPC-H testing in a data • NVMe-enabled capability delivers enterprise and cloud deployments. warehousing environment have an additional 55% lower latency and The latest Emulex Gen 6 FC HBAs demonstrated up to 71% faster supports NVMe over Fabrics and offer higher performance, lower completion times vs. the previous SCSI concurrently latency, enhanced diagnostics generations of HBAs. To enable the Better Virtualization and manageability for Cisco highest Virtual Machine density, UCS C-Series rack servers. The • Near limitless scalability to support Gen 6 HBAs provide support for maximum VM density with 2X more LPe32000-series HBAs are available up to 255 virtual functions, 1,024 on-chip resources & bandwidth with single or dual 32GFC optics. Message Signaled Interrupts and • Improved VDI experience with low- The LPe31000 is available with dual- expansive on-board context for latency HBAs providing noticeable port 16GFC optics. exchanges and logins. improvements during boot storms • Simplified management & installation Unique to Fibre Channel technology with OneCommand Manager plug-in is its deep ecosystem support for VMware vCenter server making it ideal for large scale, easy- 1. Demartek TPC-H testing performed with Emulex Gen 6 FC HBAs in a Microsoft Lossless, Reliable to-manage storage deployments. SQL Server environment vs. the previous Networking Users can count on a complete generations of HBAs suite of management software, in- • Near zero downtime— FC’s lossless 2. Based on published FIELD MTBF of 10 design ensures no dropped packets box drivers for mainstream server million hours for the Emulex family of FC HBAs. and maximum uptime operating systems, software-defined EMULEX • Industry Leader for Reliability— storage APIs and tools, and the Emulex HBAs can provide up to 1,141 strength to support high service- years of uninterrupted service!2 level agreement (SLA) applications. Emulex Gen 6 Fibre Channel HBAs for Cisco UCS C-Series Product Brief NVM Express (NVMe) is a relatively transmission. FEC then provides the Control new protocol for solid-state storage receiver with the ability to correct devices built with non-volatile errors without a reverse channel to The flagship OneCommand® memory technologies. NVMe request the retransmission of data, Manager enterprise-class provides substantially lower latency which improves performance. management application features for storage I/O operations and a multiprotocol, cross-platform significantly higher IOPS per device. T10 Protection Information architecture that provides NVMe scales-up the number of (T10-PI) data integrity with high centralized management of all devices it can address by adopting performance hardware offload current and previous generations NVMe over Fabrics technology. provides data protection from the of Emulex FC HBAs. This enables IT server to the storage array. As administrators to manage network Emulex Gen 6 HBAs are NVMe one of the founders of the Data connectivity with one tool for over Fabrics-enabled, providing Integrity Initiative (DII), Emulex, maximum efficiency. an additional 55% lower latency along with Oracle and Seagate, for storage I/O operations versus was instrumental in defining the Emulex HBA troubleshooting is TM SCSI. Gen 6 NVMe-enabled T10-PI standard, which, along simplified with OneCapture , an HBAs support NVMe over Fabrics with the Data Integrity Extensions Emulex device driver utility that and SCSI concurrently, allowing (DIX) standard, delivers full gathers system, adapter, device datacenters to transition to all-flash end-to-end data integrity. T10- driver, and applications information. storage at their own pace. PI assures the validity of I/O Data collected by OneCapture operations through the exchange of is compressed into a single file and can be sent to Broadcom Protect verification information during data transmissions. Technical Support for analysis when Emulex Gen 6 FC HBAs deliver debugging system issues or for enhanced security via the new Emulex HBAs are renowned for diagnostic purposes. secure firmware update feature reliability, ensuring maximum which protects and ensures the SAN uptime. Their “It Just Works” authenticity of device firmware. reputation is based on 17 million installed ports with proven Forward Error Correction (FEC) industry-leading reliability of 10 is a Gen 6 Fibre Channel standard million hours field Mean Time feature that provides enhanced Between Failures (MTBF). data reliability and performance by automatically detecting and recovering from bit errors. It is especially useful in diverse and complex user environments such as blade system implementations. FEC is a digital signal processing technique that introduces redundant data, called an error correcting code, prior to data Emulex Gen 6 Fibre Channel HBAs for Cisco UCS C-Series Product Brief Standards Comprehensive OS and Agency and Safety Approvals Hypervisor Support General Specifications North America • Microsoft Windows • The LPe31000/LPe32000-series FC • FCC/ICES Class A • Red Hat Enterprise Linux HBAs are powered by the XE501 • UL/CSA Recognized controller and utilizes an eight-lane (x8) • SUSE Linux Enterprise Server PCIe 3.0 bus (backward compatibility to • VMware vSphere Europe PCIe 2.0 supported)—the architecture • CE Mark enables all resources to be applied to Hardware Environments • EU RoHS compliant any port that needs it, delivering over 1.6M IOPS on a single-port • Cisco UCS Series • TUV Bauart Certified Optical Australia Industry Standards • RCM • Data rates: 28.05 Gb/s (32GFC); • Current ANSI/IETF Standards: FC-PI-4; 14.025 Gb/s (16GFC); 8.5 Gb/s (8GFC); Japan FC-PI-5; FC-PI-6; FC-FS-3; FC-LS-2; 4.25 Gb/s (4GFC) automatically • VCCI Class A FC-GS-6; FC-DA; FC-DA-2; FCP-4; negotiated SPC-4; SBC-3; SSC-4 Taiwan • Optics: Short wave lasers with LC type • Legacy ANSI/IETF standards: FC-PH; connector • BSMI Class A FC-PH-2; FC-PH-3; FC-PI; FC-PI-2; FC-PI-3; FC-FS; FC-GS-2/3/4/5; FCP-2/3; • Cable: Operating at 32Gb Korea FC-HBA; FC-TAPE; FC-MI; SPC-3; SBC-2; - 20m at 32Gb on 50/125 μm OM2 MMF • MSIP (formerly KCC/MIC) Class A SSC-2; SSC-3 - 70m at 32Gb on 50/125 μm OM3 MMF China • PCIe base spec 3.0 - 100m at 32Gb on 50/125 μm OM4 MMF • China RoHS Compliant • PCIe card electromechanical spec 3.0 • Fibre Channel Class 3 Physical Dimensions • PHP hot plug-hot swap • Short, low profile PCIe card • 167.64mm x 68.91mm (6.60” x 2.71”) Architecture • Standard bracket (low profile bracket ships in box) Single-port LPe32000 or dual-port LPe32002 • Supports 32GFC, 16GFC and 8GFC link Environmental Requirements speeds, automatically negotiated • Operating temperature: 0° to 55°C (32° to 131°F); 150 LFM required Dual-port LPe31000 • Storage temperature: -20° to 85°C • Supports 16GFC, 8GFC and 4GFC link (-4° to 185°F) speeds, automatically negotiated • Relative humidity: 5% to 95% non-condensing Emulex Gen 6 Fibre Channel HBAs for Cisco UCS C-Series Product Brief Ordering Information Added Features Management Features • The Emulex OneCommand Manager The LPe31000/LPe32000-series is Performance Features application enables centralized discovery, available from Cisco using the following • Doubling the maximum FC link rate monitoring, reporting, and administration part numbers: from 16GFC to 32GFC and enhanced of HBAs provided by Emulex on local virtualization capabilities, help support IT LPe32000-M2 and remote hosts. Powerful automation “green” initiatives. Part Number: UCSC-PCIE-BS32GF capabilities facilitate remote driver • Frame-level multiplexing increases • 1 Port 32GFC Short Wave Optical – parameter, firmware and boot code link efficiency and maximizes HBA LC SFP+ (32GFC optical transceiver upgrades. performance. included) • Advanced diagnostic features, such as • Accelerates network access to SSDs adapter port beaconing and adapter LPe32002-M2 with NVMe over Fibre Channel-enabled statistics, help optimize management Part Number: UCSC-PCIE-BD32GF feature- supports the upcoming NVMe and network performance, while the • 2 Port 32GFC Short Wave Optical – over FC T11 standard environmental monitoring feature LC SFP+ (32GFC optical transceivers helps to maintain optimum host-to- Data Protection Features included) fabric connections. In addition to the • End-to-end data protection with GUI interface, management functions LPe31002-M6 hardware parity, CRC, ECC and other can also be performed via a scriptable Part Number: UCSC-PCIE-BD16GF advanced error checking and correction Command Line Interface (CLI) as well as • 2 Port 16GFC Short Wave Optical – algorithms ensure data is safe from a web browser. LC SFP+ (16GFC optical transceivers corruption. • Meet SLAs and QoS with ExpressLane included) • Enhanced silent data corruption application prioritization on hosts.
Recommended publications
  • SAS Enters the Mainstream Although Adoption of Serial Attached SCSI
    SAS enters the mainstream By the InfoStor staff http://www.infostor.com/articles/article_display.cfm?Section=ARTCL&C=Newst&ARTICLE_ID=295373&KEYWORDS=Adaptec&p=23 Although adoption of Serial Attached SCSI (SAS) is still in the infancy stages, the next 12 months bode well for proponents of the relatively new disk drive/array interface. For example, in a recent InfoStor QuickVote reader poll, 27% of the respondents said SAS will account for the majority of their disk drive purchases over the next year, although Serial ATA (SATA) topped the list with 37% of the respondents, followed by Fibre Channel with 32%. Only 4% of the poll respondents cited the aging parallel SCSI interface (see figure). However, surveys of InfoStor’s readers are skewed by the fact that almost half of our readers are in the channel (primarily VARs and systems/storage integrators), and the channel moves faster than end users in terms of adopting (or at least kicking the tires on) new technologies such as serial interfaces. Click here to enlarge image To get a more accurate view of the pace of adoption of serial interfaces such as SAS, consider market research predictions from firms such as Gartner and International Data Corp. (IDC). Yet even in those firms’ predictions, SAS is coming on surprisingly strong, mostly at the expense of its parallel SCSI predecessor. For example, Gartner predicts SAS disk drives will account for 16.4% of all multi-user drive shipments this year and will garner almost 45% of the overall market in 2009 (see figure on p. 18).
    [Show full text]
  • Gen 6 Fibre Channel Technology
    WHITE PAPER Better Performance, Better Insight for Your Mainframe Storage Network with Brocade Gen 6 TABLE OF CONTENTS Brocade and the IBM z Systems IO product team share a unique Overview .............................................................. 1 history of technical development, which has produced the world’s most Technology Highlights .................................. 2 advanced mainframe computing and storage systems. Brocade’s Gen 6 Fibre Channel Technology technical heritage can be traced to the late 1980s, with the creation of Benefits for z Systems and Flash channel extension technologies to extend data centers beyond the “glass- Storage ................................................................ 7 house.” IBM revolutionized the classic “computer room” with the invention Summary ............................................................. 9 of the original ESCON Storage Area Network (SAN) of the 1990s, and, in the 2000s, it facilitated geographically dispersed FICON® storage systems. Today, the most compelling innovations in mainframe storage networking technology are the product of this nearly 30-year partnership between Brocade and IBM z Systems. As the flash era of the 2010s disrupts between the business teams allows both the traditional mainframe storage organizations to guide the introduction networking mindset, Brocade and of key technologies to the market place, IBM have released a series of features while the integration between the system that address the demands of the data test and qualification teams ensures the center. These technologies leverage the integrity of those products. Driving these fundamental capabilities of Gen 5 and efforts are the deep technical relationships Gen 6 Fibre Channel, and extend them to between the Brocade and IBM z Systems the applications driving the world’s most IO architecture and development teams, critical systems.
    [Show full text]
  • Serial Attached SCSI (SAS)
    Storage A New Technology Hits the Enterprise Market: Serial Attached SCSI (SAS) A New Interface Technology Addresses New Requirements Enterprise data access and transfer demands are no longer driven by advances in CPU processing power alone. Beyond the sheer volume of data, information routinely consists of rich content that increases the need for capacity. High-speed networks have increased the velocity of data center activity. Networked applications have increased the rate of transactions. Serial Attached SCSI (SAS) addresses the technical requirements for performance and availability in these more I/O-intensive, mission-critical environments. Still, IT managers are pressed on the other side by cost constraints and the need White paper for flexibility and scalability in their systems. While application requirements are the first measure of a storage technology, systems based on SAS deliver on this second front as well. Because SAS is software compatible with Parallel SCSI and is interoperable with Serial ATA (SATA), SAS technology offers the ability to manage costs by staging deployment and fine-tuning a data center’s storage configuration on an ongoing basis. When presented in a small form factor (SFF) 2.5” hard disk drive, SAS even addresses the increasingly important facility considerations of space, heat, and power consumption in the data center. The backplanes, enclosures and cabling are less cumbersome than before. Connectors are smaller, cables are thinner and easier to route impeding less airflow, and both SAS and SATA HDDs can share a common backplane. White paper Getting this new technology to the market in a workable, compatible fashion takes various companies coming together.
    [Show full text]
  • EMC’S Perspective: a Look Forward
    The Performance Impact of NVM Express and NVM Express over Fabrics PRESENTATION TITLE GOES HERE Live: November 13, 2014 Presented by experts from Cisco, EMC and Intel Webcast Presenters J Metz, R&D Engineer for the Office of the CTO, Cisco Amber Huffman, Senior Principal Engineer, Intel Steve Sardella , Distinguished Engineer, EMC Dave Minturn, Storage Architect, Intel SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and individual members may use this material in presentations and literature under the following conditions: Any slide or slides used must be reproduced in their entirety without modification The SNIA must be acknowledged as the source of any material used in the body of any document containing material from these presentations. This presentation is a project of the SNIA Education Committee. Neither the author nor the presenter is an attorney and nothing in this presentation is intended to be, or should be construed as legal advice or an opinion of counsel. If you need legal advice or a legal opinion please contact your attorney. The information presented herein represents the author's personal opinion and current understanding of the relevant issues involved. The author, the presenter, and the SNIA do not assume any responsibility or liability for damages arising out of any reliance on or use of this information. NO WARRANTIES, EXPRESS OR IMPLIED. USE AT YOUR OWN RISK. 3 What This Presentation Is A discussion of a new way of talking to Non-Volatile
    [Show full text]
  • Comparing Fibre Channel, Serial Attached SCSI (SAS) and Serial ATA (SATA)
    Comparing Fibre Channel, Serial Attached SCSI (SAS) and Serial ATA (SATA) by Allen Hin Wing Lam Bachelor ofElectrical Engineering Carleton University 1996 PROJECT SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF ENGINEERING In the School ofEngineering Science © Allen Hin Wing Lam 2009 SIMON FRASER UNIVERSITY Fall 2009 All rights reserved. However, in accordance with the Copyright Act ofCanada, this work may be reproduced, without authorization, under the conditions for Fair Dealing. Therefore, limited reproduction ofthis work for the purposes ofprivate study, research, criticism, review and news reporting is likely to be in accordance with the law, particularly ifcited appropriately. Approval Name: Allen Hin Wing Lam Degree: Master ofEngineering Title ofProject: Comparing Fibre Channel, Serial Attached SCSI (SAS) and Serial ATA (SATA) Examining Committee: Chair: Dr. Daniel Lee Chair ofCommittee Associate Professor, School ofEngineering Science Simon Fraser University Dr. Stephen Hardy Senior Supervisor Professor, School ofEngineering Science Simon Fraser University Jim Younger Manager, Product Engineering PMC- Sierra, Inc. Date ofDefence/Approval r 11 SIMON FRASER UNIVERSITY LIBRARY Declaration of Partial Copyright Licence The author, whose copyright is declared on the title page of this work, has granted to Simon Fraser University the right to lend this thesis, project or extended essay to users of the Simon Fraser University Library, and to make partial or single copies only for such users or in response
    [Show full text]
  • Brocade G620 Switch Datasheet
    DATA SHEET Brocade G620 Switch Ultra-dense, Highly Scalable, Easy-to-Use Enterprise-Class Storage Networking Switch HIGHLIGHTS Today’s mission-critical storage environments require greater • Provides high scalability in an ultra- consistency, predictability, and performance to keep pace with growing dense, 1U, 64-port switch to support business demands. Faced with explosive data growth, data centers high-density server virtualization, need more IO capacity to accommodate the massive amounts of data, cloud architectures, and flash-based applications, and workloads. In addition to this surge in data, collective storage environments expectations for availability continue to rise. Users expect applications to • Increases performance for demanding workloads across 32 Gbps links and be available and accessible from anywhere, at any time, on any device. shatters application performance barriers with up to 100 million IOPS To meet these dynamic and growing The Brocade® G620 Switch meets the • Enables “pay-as-you-grow” business demands, organizations need to demands of hyper-scale virtualization, scalability—with 24 to 64 ports—for deploy and scale up applications quickly. larger cloud infrastructures, and growing on-demand flexibility As a result, many are moving to higher flash-based storage environments by • Provides proactive, non-intrusive, Virtual Machine (VM) densities to enable delivering market-leading Gen 6 Fibre real-time monitoring and alerting of rapid deployment of new applications Channel technology and capabilities. It storage IO health and performance and deploying flash storage to help those provides a high-density building block for with IO Insight, the industry’s first applications scale to support thousands increased scalability, designed to support integrated network sensors of users.
    [Show full text]
  • Untangled: Improve Efficiency with Modern Cable Choices PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek Agenda
    Untangled: Improve Efficiency with Modern Cable Choices PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek Agenda About Demartek Why Discuss Cables and Connectors? Cables Copper Fiber-Optic Connectors Demartek Free Resources 2015 Data Storage Innovation Conference. © Demartek All Rights Reserved. 2 Demartek Video Click to view this one minute video (available in 720p and 1080p) Demartek YouTube Channel: http://www.youtube.com/user/Demartek/videos http://www.demartek.com/Demartek_Video_Library.html 2015 Data Storage Innovation Conference. © Demartek All Rights Reserved. 3 About Demartek Industry Analysis and ISO 17025 accredited test lab Lab includes servers, networking & storage Ethernet: 1, 10 & 40 Gbps: NFS, SMB (CIFS), iSCSI, FCoE and SR-IOV Fibre Channel: 4, 8 & 16 Gbps Servers: 8+ cores, large RAM Virtualization: VMware, Hyper-V, Xen, KVM We prefer to run real-world applications to test servers and storage solutions (databases, Hadoop, etc.) Website: www.demartek.com/TestLab 2015 Data Storage Innovation Conference. © Demartek All Rights Reserved. 4 Why Discuss Cables and Connectors? Cabling is not as well known among IT staff Some jurisdictions have cable-related ordinances Often related to fire prevention How long do you keep the following in service? Servers Storage systems Network switches Network cables Many examples in this presentation show Ethernet but can be and often are applied to other interfaces 2015 Data Storage Innovation Conference. © Demartek All Rights Reserved. 5 Cable Life Laying of network cables can be labor-intensive Cable trays, inside walls, etc. Fiber optic cabling service life: 15 – 20 years Cable choices must meet existing needs and future technology needs What speeds of Ethernet, Fibre Channel, Infiniband, SAS/SCSI & USB were you running 5, 10, 15 years ago? 2015 Data Storage Innovation Conference.
    [Show full text]
  • Fibre Channel Solution Guide
    Fibre Channel Solutions Guide 2019 fibrechannel.org FIBRE CHANNEL Powering the next generation private, public, and hybrid cloud storage networks ABOUT THE FCIA The Fibre Channel Industry Association (FCIA) is a non-profit international organization whose sole purpose is to be the independent technology and marketing voice of the Fibre Channel industry. We are committed to helping member organizations promote and position Fibre Channel, and to providing a focal point for Fibre Channel information, standards advocacy, and education. CONTACT THE FCIA For more information: www.fibrechannel.org • [email protected] TABLE OF CONTENTS Foreword .........................................................................................3 FCIA President Introduction.............................................................4 The State of Fibre Channel by Storage Switzerland .......................6 Fibre Channel New Technologies: FC-NVMe-2 ............................... 7 The 2019 Fibre Channel Roadmap ................................................. 8 Fibre Channel’s Future is Bright in Media and Entertainment ......10 Securing Fibre Channel SANs with End-to-End Encryption ..........12 FOREWORD By Rupin Mohan, FCIA Marketing Chairman; Director R&D and CTO, Hewlett-Packard Enterprise It’s 2019, and Fibre Channel continues to remain the premier storage fabric connectivity protocol in today’s data centers. Fibre Channel is deployed by thousands of customers in their data centers around the world and 80–90% of all All-Flash storage arrays are connected to servers via Fibre Channel. Customers have recently made a considerable investment in Gen 6 (32GFC), and given the 4-5-year depreciation cycle, this equipment will continue to run critical business applications requiring reliable, fast and scalable storage infrastructure. The NVMe over Fibre Channel (FC-NVMe) standard is published, and we see products being announced and released in the market across the board.
    [Show full text]
  • Nvme Over Fibre Channel) Qlogic® Enhanced 16GFC / 32GFC Hbas Concurrent FCP (FC-SCSI) and FC-Nvme (Nvme/FC)
    White Paper FC-NVMe (NVMe over Fibre Channel) QLogic® Enhanced 16GFC / 32GFC HBAs Concurrent FCP (FC-SCSI) and FC-NVMe (NVMe/FC) August 2021 Background and Summary Back in 1956, the world’s first hard disk drive (HDD) shipped, setting a path for subsequent generations of drives with faster spinning media and increasing SAS speeds. Then in the early 1990s, various manufacturers introduced storage devices known today as flash- based or dynamic random access memory (DRAM)-based solid state disks (SSDs). The SSDs had no moving (mechanical) components, which allowed them to deliver lower latency and significantly faster access times. HDDs and SSDs have evolved, along with new and faster bus architectures such as PCI Express (PCIe) which have helped to further improve access speeds and reduce latency in conjunc- tion with the Non Volatile Memory Express (NVMe) standard and the ensuing products. Fibre Channel (FC) is a high-speed network technology primarily used to connect enterprise servers to HDD- or SSD-based data storage. 8GFC, 16GFC and 32GFC are the dominant speeds today (with a strong roadmap to 64GFC and beyond). Fibre Channel is standardized in the T11 Technical Committee of the International Committee for Information Technology Standards (INCITS) and has remained the dominant protocol to access shared storage for many decades. Fibre Channel Protocol (FCP) is a transport protocol that predominantly transports SCSI commands over Fibre Channel networks. With the advent of NVMe, FC has transformed to natively transport NVMe and this technological capability is called FC-NVMe. The Evolution of Disk and Fabric 32GFC & FC-NVMe 16GFC & FC-NVMe FC “NVMe” Over Fibre Channel “SCSI” Over Fibre Channel Performance Non-Volatile Memory “Spinning” Drive SAS/SATA “Flash” “Express” (NVMe) Today Time Figure 1: Evolution of Disk and Fibre Channel Fabric SCSI and NVMe Differences While the SCSI/AHCI interface comes with the benefit of wide software compatibility, it cannot deliver optimal performance when used with SSDs connected via the PCIe bus.
    [Show full text]
  • Intel® Omni-Path Fabric Suite Fabric Manager — User Guide
    Intel® Omni-Path Fabric Suite Fabric Manager User Guide November 2015 Order No.: H76468-1.0 You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest Intel product specifications and roadmaps. The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Copies of documents which have an order number and are referenced in this document may be obtained by calling 1-800-548-4725 or visit http:// www.intel.com/design/literature.htm. Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software or service activation. Learn more at http://www.intel.com/ or from the OEM or retailer. No computer system can be absolutely secure. Intel, the Intel logo, Intel Xeon Phi, and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright © 2015, Intel Corporation. All rights reserved. Intel® Omni-Path Fabric Suite Fabric Manager User Guide November 2015 2 Order No.: H76468-1.0 Revision History—Intel® Omni-Path Fabric Revision History Date Revision Description November 2015 1.0 Document has been updated for Revision 1.0.
    [Show full text]
  • PCI Express Impact on Storage Architectures and Future Data Centers
    PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may use this material in presentations and literature under the following conditions: Any slide or slides used must be reproduced in their entirety without modification The SNIA must be acknowledged as the source of any material used in the body of any document containing material from these presentations. This presentation is a project of the SNIA Education Committee. Neither the author nor the presenter is an attorney and nothing in this presentation is intended to be, or should be construed as legal advice or an opinion of counsel. If you need legal advice or a legal opinion please contact your attorney. The information presented herein represents the author's personal opinion and current understanding of the relevant issues involved. The author, the presenter, and the SNIA do not assume any responsibility or liability for damages arising out of any reliance on or use of this information. NO WARRANTIES, EXPRESS OR IMPLIED. USE AT YOUR OWN RISK. PCI Express Impact on Storage Architectures and Future Data Centers © 2010 Storage Networking Industry Association. All Rights Reserved. 2 Abstract PCI Express Impact on Storage Architectures and Future Data Centers • PCI Express Gen2 and Gen3, IO Virtualization, FcoE, SSD are here or coming soon. This session describes PCI Express, Single Root and Multi Root IOV and the implications on FCoE, SSD and impacts of all these changes on storage connectivity, storage transfer rates.
    [Show full text]
  • 3U 16 Bay Thunderbolt Storage and Pcie Expansion
    DAS >> Thunderbolt >> Rackmount SAS/SATA Making High Speed SAN Available to Mac mini Server Any Fibre Channel HBA or 10G network interface card with Thunderbolt Aware driver can be installed inside the ● NA333TB 3U 16-bay enclosure to make SAN available to Mac mini Server. By the network interface card inside NA333TB and the Xsan software on Mac mini Server, video editors of work-group in collaboration are able to request and share data immediately through the high-speed Fibre Channel or 10G Ethernet SAN network. Hardware RAID ● Mac mini 3U 16 Bay Thunderbolt Storage ● NA333TB and PCIe Expansion Specifications Rugged 3U 16-bay rackmount chassis Model NA333TB Thunderbolt interface with 10Gbps of throughput in both channels Host Interface Thunderbolt™ Supports sixteen (16) SAS/SATA (6G/3Gbps) HDD Trays Data Transfer Rate 10Gbps Bi-directional Supports up to 3 PCIe slots for RAID card, Fibre Channel HBA/10G networking card, HDD Interface SAS/SATA (3/6 Gbps) No. of Disk(s) Up to 16 and any standard PCIe add-on cards with Thunderbotl Aware's Driver. RAID Levels Requires a RAID card with internal 16 port and Thunderbolt driver(RAID card sold separately) Individual key lock on each HDD tray for physical security PCIe Slot Expansion Two PCIe2.0 x8 and One PCIe2.0 x4 Server-grade redundant power supply for zero-down-time Thunderbolt Expansion Up to Six Thunderbolt devices LED Display for Enclosure Fan normal - green; Fan failure - red Temp. normal - green; Temp. over 50°C - red LED Display for each Tray White - Power On Indicator Overview Flash Blue - HDD Accessing Indicator Red - HDD Failure Indicator Netstor NA333TB is the first Thunderbolt™ rackmount solution combined with storage and PCIe expansion Alarm Mutable buzzer beeping for fan failure or over temperature occurs function ideal for video editors and video professionals who use the Thunderbolt-equipped concise form-factor Material Heavy-duty cold-rolled steel Housing computers such as Mac mini, iMac, MacBook Pro for their work.
    [Show full text]