Putting Serial Attached SCSI to Work for You

Total Page:16

File Type:pdf, Size:1020Kb

Putting Serial Attached SCSI to Work for You SAS END-USER GUIDE Putting Serial Attached SCSI to Work for You INTRODUCTION Moving to Serial Technologies Parallel SCSI technology has been the widely deployed standard in server and storage Over the past three years, Serial data centers for the last 20 years. While parallel SCSI has been a reliable standard Attached SCSI (SAS) has been interface, the technology has reached its highest performance level with the advent of unveiled as the next evolution of Ultra320. As servers are pushed to meet advancing system and application computing the SCSI standard — featuring requirements, parallel SCSI has struggled with signal skew and crosstalk, signal increased performance, termination restrictions, cable and connector reflections, and device addressability — scalability, and reliability, while all of which have become barriers to next-generation throughput performance. maintaining ease-of-use and the Industry leaders in server and storage computing have been working together to SCSI feature set that has made overcome this throughput performance challenge. The result of this intensive SCSI the de facto standard in investigation has resulted in transitioning parallel SCSI to a serial interface. Serial enterprise computing technology transmits data in a single stream instead of the multiple streams found in environments. The first SAS parallel technology, therefore it is not tied to a particular clock speed and can transfer data at a much higher rate (up to 30 times faster) than parallel technology. It also offers products are starting to become greater reliability and scalability. available, and represent the first step in making SAS a widely Serial technology is not new. In fact, the SCSI evolution was based on the widely pervasive serial network already deployed in the datacenter. In the late 1990s, storage adopted technology standard. utilization and growth were critical issues facing the datacenter. The result was proposals This guide from Adaptec will and products that aggregated storage on a dedicated ‘storage network’.This helped IT help you understand Serial managers to consolidate and effectively manage and grow their aggregated enterprise data Attached SCSI: what it is, how it pools. Yet, successful implementation required long distance support and high speed with minimal latency to provide rapid access to critical information that was now consolidated works, how it can help you get away from the data center. The answer was Fibre Channel, the first serial technology to higher storage performance at a gain significant momentum in the mainstream enterprise marketplace. lower price point, and how to put By 2002, storage networks had become pervasive in the enterprise. Yet the amount of this transition to the best use for information continued to grow, in response to the efficiency of these networks and the your existing storage and future user perspective that all data is critical data. This organic data growth coincided with storage needs. strict new government data retention requirements (e.g. Sarbanes-Oxley) that meant that For many years Adaptec has been a new “class” of storage — non-mission-critical data — had to be kept readily accessible for a number of years. So, the industry wrestled with the next major technology the leader in SCSI products and requirement, a way to cost-effectively manage the exploding amount of storage content in technology, and is bringing this the IT infrastructure. expertise to the SAS market. Cost became the principle focus. Solution vendors and industry leaders responded with During the transition to SAS, the introduction of Serial ATA (SATA), which serialized the low-cost, high-volume count on us to provide you with desktop-class ATA hard drives with a new interface that provided adequate reliability and the information you need to use performance for non-mission-critical information. Companies with data protection this technology and get the most expertise, such as Adaptec, responded by helping to drive best-in-class RAID technology, from your storage investment. that when paired with SATA hard drives, provided optimized technology at a much lower cost. SATA also provided higher disk interconnect speeds of 1.5Gb/s (SATA I) and 3Gb/s (SATA II). The future is exciting for SATA, as speeds continue to increase (up to 6Gb/s in the future) and some enterprise capabilities will be enhanced, including hot swap and simplified cabling. Meanwhile, the technology will maintain the ATA family commitment of driving the lowest acquisition cost per megabyte for enterprise IT centers. SAS END-USER GUIDE Putting Serial Attached SCSI to Work for You 2 SAS delivers the high What is Serial Attached SCSI? performance, scalability, and Finally, the most pervasive enterprise technology has come to a crossroads. Parallel SCSI reliability required for bandwidth- is the heart of the datacenter, used as the standard interconnect and hard drive hungry mainstream servers and communication scheme for server and storage environments. Companies had been enterprise storage. developing and utilizing SCSI for over 20 years as the mainstay for enterprise storage. But the technology’s future was coming into question. Quite simply, the parallel interface SAS lends itself to the high- would have to be overhauled to address next generation concerns of signal integrity, frequency, immediate random performance and reliability, right down to fundamentals like cable length. data access required for The result of three years of industry discussions and technological investigation is Serial transactional data applications Attached SCSI (SAS), the next standard in enterprise server and storage technology. SAS such as online purchases and bank is a high-performance solution that leverages proven SCSI functionality, and builds on transactions and provides the the enterprise expertise of multiple chip, board, drive, subsystem, and server performance and security required manufacturers throughout the industry. It provides better performance and flexibility for mission-critical applications than the serial technology, Fibre Channel, at a lower cost and with the same, or ever which demand data redundancy. better, reliability. Key SAS Features Include: “Adaptec validates the vision • SAS and SATA drive support providing an unprecedented level of choice in the of the Serial Attached SCSI enterprise — the flexibility of integrating either SAS and/or SATA devices in common standard – with its SCSI server or storage solutions, providing customization to meet cost or performance technology leadership, needs in unique business environments comprehensive understanding • reliable point-to-point connections at 3Gb/s — up to 128 devices (or 16,256 of reseller and end-user addressable devices per port) requirements, and a broad range • full dual-ported connections for performance or failover capabilities, delivering robust of products that can be mix-and- data protection and reliability right to the hard drive • enterprise features including native command queuing and greater than 2TB LUN matched into SAS-based solutions support that meet a new range of storage • available in multiple hot-swappable disk drive performance and form factor performance and pricepoint configurations including high value 3.5” 10k rpm drives, high performance 3.5” 15k needs.” rpm drives and emerging 2.5” high density drives for performance server and specialized high-performance storage applications Greg Schulz, Sr. Analyst, • thinner cabling than SCSI and ATA which delivers new cooling metrics and more The Evaluator Group efficient airflow — critical in a dense computing environment where low profile servers are racked and stacked with multiple external storage chassis. Effective heat management and cooling schemes remain a top priority for IT managers today delivering enhanced uptime and reliability guarantees in application sensitive environments. SAS delivers the high performance, scalability, and reliability required for bandwidth- hungry mainstream servers and enterprise storage. SAS lends itself to the high-frequency, immediate random data access required for transactional data applications such as online purchases and bank transactions and provides the performance and security required for mission-critical applications which demand data redundancy. Most importantly, IT managers today cannot risk deploying the wrong type of solution. Today, server or storage solutions represent finite choices — you must choose early on whether you want a SATA-optimized server or storage solution, or whether you will pay more upfront for a parallel SCSI optimized server or storage solution. If you deploy the low-cost SATA solution, but the performance and reliability metrics fail to meet internal user expectations and uptime service guarantees, the choice is straightforward — pick a weekend, forklift upgrade the application and storage infrastructure, and hope that you SAS END-USER GUIDE Putting Serial Attached SCSI to Work for You 3 can redeploy a new SCSI-based solution before the weekend is through. This does not account for the vendor negotiation of taking back the ‘slightly used’ SATA solution, and replacing it with a SCSI solution. SAS breaks these barriers. Deploying standard server and storage chassis based on SAS architecture makes it easy to purchase and maintain service spares by leveraging common components (power supplies, memory, etc.), and ensures that IT staff is up to speed and very comfortable with the server and storage solution. The most compelling part of SAS
Recommended publications
  • Scaling Enterprise Storage with SAS Hard Drives
    Whitepaper | November 2007 Scaling Enterprise Storage with SAS Hard Drives Introduction Data center workloads have increased exponentially in recent years, requiring IT managers to find new ways of scaling their enterprise storage resources in a way that is both highly reliable and cost-effective. With the introduction of complementary serial interface technologies, IT managers now have the flexibility to deploy either high performance SAS drives or cost-effective Serial ATA (SATA) drives in a Serial Attached SCSI (SAS) storage environment. Hardware compatibility between the new interfaces will provide unprecedented design flexibility for server and storage subsystem deployments. SAS was designed to be the successor to parallel SCSI, which has been used effectively as an enterprise storage interface for more than 20 years. SAS supports the SCSI com- mand set and protocol, maintaining compatibility with the last 20 years of application software investment. SAS will support faster data transfer rates and more devices per controller, as well as reduce the size and complexity of the cables and connectors (thus enabling smaller, more densely-packed disk arrays). SAS is a point-to-point serial architecture, meaning that each drive has a dedicated connection to the host. Eliminating the shared (parallel) bus bottleneck results in higher overall performance because the host will deliver full bandwidth to each individual hard drive. These dedicated, point-to-point connections provide full-duplex connectivity at 3Gb/s for superior performance. SAS is a dual-port interface that provides two separate data paths into the drive. This delivers higher levels of performance and eliminates the “single point of failure” that is a drawback of the current parallel SCSI inter- face.
    [Show full text]
  • SAS Storage Architecture: Serial Attached SCSI, 2005, Mike Jackson, 0977087808, 9780977087808, Mindshare Press, 2005
    SAS Storage Architecture: Serial Attached SCSI, 2005, Mike Jackson, 0977087808, 9780977087808, MindShare Press, 2005 DOWNLOAD http://bit.ly/1zNQCoA http://www.barnesandnoble.com/s/?store=book&keyword=SAS+Storage+Architecture%3A+Serial+Attached+SCSI SAS (Serial Attached SCSI) is the serial storage interface that has been designed to replace and upgrade SCSI, by far the most popular storage interface for high-performance systems for many years. Retaining backward compatibility with the millions of lines of code written to support SCSI devices, SAS incorporates recent advances in high-speed serial design to provide better performance, better reliability and enhanced capabilities, all at a lower cost. SAS will be a significant part of many future high-performance storage systems, and hardware designers, system validation engineers, device driver developers and others working in this area will need a working knowledge of it.SAS Storage Architecture provides a comprehensive guide to the SAS standard. The book contains descriptions and numerous examples of the concepts presented, using the same building block approach as other MindShare offerings. This book details important concepts relating to the design and implementation of storage networks.Specific topics of interest include:SATA Compatibility Expander devices Discovery Process Connection protocols Arbitration of competing connection requests Flow Control protocols ACK/NAK protocol Primitives ? construction and uses Frames ? format, definition, used of each field Error checking mechanisms
    [Show full text]
  • Fibre Channel Interface
    Fibre Channel Interface Fibre Channel Interface ©2006, Seagate Technology LLC All rights reserved Publication number: 100293070, Rev. A March 2006 Seagate and Seagate Technology are registered trademarks of Seagate Technology LLC. SeaTools, SeaFONE, SeaBOARD, SeaTDD, and the Wave logo are either registered trade- marks or trademarks of Seagate Technology LLC. Other product names are registered trade- marks or trademarks of their owners. Seagate reserves the right to change, without notice, product offerings or specifications. No part of this publication may be reproduced in any form without written permission of Seagate Technol- ogy LLC. Revision status summary sheet Revision Date Writer/Engineer Sheets Affected A 03/08/06 C. Chalupa/J. Coomes All iv Fibre Channel Interface Manual, Rev. A Contents 1.0 Contents . i 2.0 Publication overview . 1 2.1 Acknowledgements . 1 2.2 How to use this manual . 1 2.3 General interface description. 2 3.0 Introduction to Fibre Channel . 3 3.1 General information . 3 3.2 Channels vs. networks . 4 3.3 The advantages of Fibre Channel . 4 4.0 Fibre Channel standards . 5 4.1 General information . 6 4.1.1 Description of Fibre Channel levels . 6 4.1.1.1 FC-0 . .6 4.1.1.2 FC-1 . .6 4.1.1.3 FC-1.5 . .6 4.1.1.4 FC-2 . .6 4.1.1.5 FC-3 . .6 4.1.1.6 FC-4 . .7 4.1.2 Relationship between the levels. 7 4.1.3 Topology standards . 7 4.1.4 FC Implementation Guide (FC-IG) . 7 4.1.5 Applicable Documents .
    [Show full text]
  • Crack Iscsi Cake 197
    1 / 2 Crack Iscsi Cake 197 Open-E DSS V7 increases iSCSI target efficiency by supporting ... drive serial number and the drive serial number information from the robotic library), ... Open-E DSS V7 MANUAL www.open-e.com. 197 work in that User .... nuance pdf converter professional 8 crack keygen · avunu telugu movie english subtitles download torrent · Veerappan ... Crack Iscsi Cake 197.. Crack Iscsi Cake 1.97. Download. Crack Iscsi Cake 1.97. ISCSI...CAKE...1.8.0418...CRACK.. Merci..de..tlcharger..iSCSI.. Contribute to Niarfe/hack-recommender development by creating an account on GitHub. ... 197, ETAP. 198, EtQ. 199, Cincom Eloquence ... 1022, Adobe Target. 1023, Adobe ... 3485, Dell EqualLogic PS6500E iSCSI SAN Storage. 3486, Dell .... iscsi cake, iscsi cake crack, iscsi cake 1.8 crack full, iscsi cake 1.97 full, iscsi cake tutorial, iscsi cake 1.9 crack, iscsi cake 1.9 full, iscsi cake .... Crack Iscsi Cake 197 iscsi cake, iscsi cake 1.8 crack full, iscsi cake 1.9, iscsi cake full, iscsi cake 1.9 expired, iscsi cake crack, iscsi cake 1.9 full, .... Crack Iscsi Cake 197. June 16 2020 0. iscsi cake, iscsi cake 1.8 crack full, iscsi cake full, iscsi cake 1.8 serial number, iscsi cake 1.9, iscsi cake crack, iscsi cake ... Serial interface and protocol. Standard PC mice once used the RS-232C serial port via a D-subminiature connector, which provided power to run the mouse's .... Avira Phantom VPN Pro v3.7.1.26756 Final Crack (2018) .rar · fb limiter pro cracked full version ... Crack Iscsi Cake 197 · Hoshi Wo Katta Hi ...
    [Show full text]
  • HP Proliant G6 Intel Xeon Bladesystem C-Class Server Blades
    Technologies in HP ProLiant G6 c-Class server blades with Intel® Xeon® processors technology brief Abstract.............................................................................................................................................. 2 ProLiant c-Class server blade architecture................................................................................................ 2 Processor technologies ......................................................................................................................... 3 Multi-level caches............................................................................................................................. 3 QuickPath Interconnect controller ....................................................................................................... 4 Hyper-Threading .............................................................................................................................. 4 Turbo Boost technology..................................................................................................................... 5 Thermal Logic technologies ................................................................................................................... 5 Processor socket technology.................................................................................................................. 6 Memory technologies ........................................................................................................................... 6 I/O technologies
    [Show full text]
  • SAS Enters the Mainstream Although Adoption of Serial Attached SCSI
    SAS enters the mainstream By the InfoStor staff http://www.infostor.com/articles/article_display.cfm?Section=ARTCL&C=Newst&ARTICLE_ID=295373&KEYWORDS=Adaptec&p=23 Although adoption of Serial Attached SCSI (SAS) is still in the infancy stages, the next 12 months bode well for proponents of the relatively new disk drive/array interface. For example, in a recent InfoStor QuickVote reader poll, 27% of the respondents said SAS will account for the majority of their disk drive purchases over the next year, although Serial ATA (SATA) topped the list with 37% of the respondents, followed by Fibre Channel with 32%. Only 4% of the poll respondents cited the aging parallel SCSI interface (see figure). However, surveys of InfoStor’s readers are skewed by the fact that almost half of our readers are in the channel (primarily VARs and systems/storage integrators), and the channel moves faster than end users in terms of adopting (or at least kicking the tires on) new technologies such as serial interfaces. Click here to enlarge image To get a more accurate view of the pace of adoption of serial interfaces such as SAS, consider market research predictions from firms such as Gartner and International Data Corp. (IDC). Yet even in those firms’ predictions, SAS is coming on surprisingly strong, mostly at the expense of its parallel SCSI predecessor. For example, Gartner predicts SAS disk drives will account for 16.4% of all multi-user drive shipments this year and will garner almost 45% of the overall market in 2009 (see figure on p. 18).
    [Show full text]
  • AMD Opteron™ Shared Memory MP Systems Ardsher Ahmed Pat Conway Bill Hughes Fred Weber Agenda
    AMD Opteron™ Shared Memory MP Systems Ardsher Ahmed Pat Conway Bill Hughes Fred Weber Agenda • Glueless MP systems • MP system configurations • Cache coherence protocol • 2-, 4-, and 8-way MP system topologies • Beyond 8-way MP systems September 22, 2002 Hot Chips 14 2 AMD Opteron™ Processor Architecture DRAM 5.3 GB/s 128-bit MCT CPU SRQ XBAR HT HT HT 3.2 GB/s per direction 3.2 GB/s per direction @ 0+]'DWD5DWH @ 0+]'DWD5DWH 3.2 GB/s per direction @ 0+]'DWD5DWH HT = HyperTransport™ technology September 22, 2002 Hot Chips 14 3 Glueless MP System DRAM DRAM MCT CPU MCT CPU SRQ SRQ non-Coherent HyperTransport™ Link XBAR XBAR HT I/O I/O I/O HT cHT cHT cHT cHT Coherent HyperTransport ™ cHT cHT I/O I/O HT HT cHT cHT XBAR XBAR CPU MCT CPU MCT SRQ SRQ HT = HyperTransport™ technology DRAM DRAM September 22, 2002 Hot Chips 14 4 MP Architecture • Programming model of memory is effectively SMP – Physical address space is flat and fully coherent – Far to near memory latency ratio in a 4P system is designed to be < 1.4 – Latency difference between remote and local memory is comparable to the difference between a DRAM page hit and a DRAM page conflict – DRAM locations can be contiguous or interleaved – No processor affinity or NUMA tuning required • MP support designed in from the beginning – Lower overall chip count results in outstanding system reliability – Memory Controller and XBAR operate at the processor frequency – Memory subsystem scale with frequency improvements September 22, 2002 Hot Chips 14 5 MP Architecture (contd.) • Integrated Memory Controller
    [Show full text]
  • Gen 6 Fibre Channel Technology
    WHITE PAPER Better Performance, Better Insight for Your Mainframe Storage Network with Brocade Gen 6 TABLE OF CONTENTS Brocade and the IBM z Systems IO product team share a unique Overview .............................................................. 1 history of technical development, which has produced the world’s most Technology Highlights .................................. 2 advanced mainframe computing and storage systems. Brocade’s Gen 6 Fibre Channel Technology technical heritage can be traced to the late 1980s, with the creation of Benefits for z Systems and Flash channel extension technologies to extend data centers beyond the “glass- Storage ................................................................ 7 house.” IBM revolutionized the classic “computer room” with the invention Summary ............................................................. 9 of the original ESCON Storage Area Network (SAN) of the 1990s, and, in the 2000s, it facilitated geographically dispersed FICON® storage systems. Today, the most compelling innovations in mainframe storage networking technology are the product of this nearly 30-year partnership between Brocade and IBM z Systems. As the flash era of the 2010s disrupts between the business teams allows both the traditional mainframe storage organizations to guide the introduction networking mindset, Brocade and of key technologies to the market place, IBM have released a series of features while the integration between the system that address the demands of the data test and qualification teams ensures the center. These technologies leverage the integrity of those products. Driving these fundamental capabilities of Gen 5 and efforts are the deep technical relationships Gen 6 Fibre Channel, and extend them to between the Brocade and IBM z Systems the applications driving the world’s most IO architecture and development teams, critical systems.
    [Show full text]
  • Adaptec SAS RAID.Indd
    Adaptec SAS RAID Confi guration and the Windows OS Installation Instructions Adaptec SAS RAID Confi guration and the Windows OS Installation Instructions After all the hardware has been installed, you must fi rst confi gure the SAS RAID before you install the Windows Operating System and other software drivers. 1 The Adaptec SAS RAID Controller Driver If you do not wish to confi gure Adaptec SAS RAID functions, please go directly to Section 2 for the Windows OS Installation instructions. Introduction to SAS (Serial Attached SCSI) In addition to SATA (Serial ATA) which is supported by the Intel ESB2 South Bridge, your motherboard has an Adaptec SAS (Serial Attached SCSI) 9410W Controller built in. SAS supports serial link data transfer rates up to 3Gbps. With the dynamic SAS infrastructure built in, your motherboard supports both SATA and SAS, providing the user with unparalleled data storage expansion and inter-con- nectivity capability. Using the Adaptec RAID Confi guration Utility The onboard SAS Controller is enabled by default. To disable it, please set the SAS Enable Jumper to Pins 2-3 (See the Jumper Section in Chapter 2 of your motherboard manual for details.) When the system is detecting the SAS Controller BIOS, make sure that the 16-digit Adapter WWN address displays. If this number is not shown, you will not be able to use the controller. *Once the WWN address appears, press the <Ctrl> and <A> keys simultaneously when prompted to access the Adaptec SAS RAID BIOS. (Note: Use the arrow keys to highlight an item and then press <Enter> to select an option.
    [Show full text]
  • Architecture and Application of Infortrend Infiniband Design
    Architecture and Application of Infortrend InfiniBand Design Application Note Version: 1.3 Updated: October, 2018 Abstract: Focusing on the architecture and application of InfiniBand technology, this document introduces the architecture, application scenarios and highlights of the Infortrend InfiniBand host module design. Infortrend InfiniBand Host Module Design Contents Contents ............................................................................................................................................. 2 What is InfiniBand .............................................................................................................................. 3 Overview and Background .................................................................................................... 3 Basics of InfiniBand .............................................................................................................. 3 Hardware ....................................................................................................................... 3 Architecture ................................................................................................................... 4 Application Scenarios for HPC ............................................................................................................. 5 Current Limitation .............................................................................................................................. 6 Infortrend InfiniBand Host Board Design ............................................................................................
    [Show full text]
  • M.2 2280 Sata Ssd
    Product Datasheet Version 1 M.2 2280 SATA SSD Product Name: I M 2 S 3 3 3 8 Capacity: 6 4 G B 、 1 2 8 GB、 2 5 6 G B 、 5 1 2 G B 、 1 T B I Revision History Revision Date Description Editor 0 May.7. 2019 Initial release Terry Chu 1 Oct. 18. 2019 Change to IA format Steven Wang 2 Apr. 24. 2020 Add DWPD Austin Lee II Table of Contents 1.0 General Description ........................................................................................................................... 2 2.0 Mechanical Specification ................................................................................................................. 3 2.1 Physical dimensions and Weight ........................................................................................... 3 2.2 Product Dimensions .................................................................................................................. 3 3.0 Product Specification ........................................................................................................................ 5 3.1 Interface and configuration ..................................................................................................... 5 3.2 Capacity ........................................................................................................................................ 5 3.3 Performance ................................................................................................................................ 5 3.4 Electrical ......................................................................................................................................
    [Show full text]
  • Serial Attached SCSI (SAS)
    Storage A New Technology Hits the Enterprise Market: Serial Attached SCSI (SAS) A New Interface Technology Addresses New Requirements Enterprise data access and transfer demands are no longer driven by advances in CPU processing power alone. Beyond the sheer volume of data, information routinely consists of rich content that increases the need for capacity. High-speed networks have increased the velocity of data center activity. Networked applications have increased the rate of transactions. Serial Attached SCSI (SAS) addresses the technical requirements for performance and availability in these more I/O-intensive, mission-critical environments. Still, IT managers are pressed on the other side by cost constraints and the need White paper for flexibility and scalability in their systems. While application requirements are the first measure of a storage technology, systems based on SAS deliver on this second front as well. Because SAS is software compatible with Parallel SCSI and is interoperable with Serial ATA (SATA), SAS technology offers the ability to manage costs by staging deployment and fine-tuning a data center’s storage configuration on an ongoing basis. When presented in a small form factor (SFF) 2.5” hard disk drive, SAS even addresses the increasingly important facility considerations of space, heat, and power consumption in the data center. The backplanes, enclosures and cabling are less cumbersome than before. Connectors are smaller, cables are thinner and easier to route impeding less airflow, and both SAS and SATA HDDs can share a common backplane. White paper Getting this new technology to the market in a workable, compatible fashion takes various companies coming together.
    [Show full text]