Environmentally Sustainable Development

Total Page:16

File Type:pdf, Size:1020Kb

Environmentally Sustainable Development EASTLEIGH BOROUGH COUNCIL LOCAL DEVELOPMENT FRAMEWORK Environmentally Sustainable Development SUPPLEMENTARY PLANNING DOCUMENT ADOPTED 5 MARCH 2009 APPENDIX 1: SUSTAINABLE DEVELOPMENT: Technical Guidance CONTENTS Definitions 1. General Sustainable Development 2. Water 3. Energy/CO2 4. Materials and Waste 5. Green Infrastructure 6. Health and Wellbeing 7. Sustainable Management 8. Major Developments DEFINITIONS [The Code for Sustainable Homes This is for for ‘Residential development’ (all new houses and flats but not extensions and conversions nor institutional accommodation). The Code is an environmental assessment method for new homes based upon the BREEAM ‘Ecohomes’ which it replaced (in England) in April 2007. Each development to be assessed against the Code needs to be registered with the BRE by a BRE-licensed Assessor, who is employed by the developer. The development is assessed by the Assessor who awards credits when sufficient documentary proof has been supplied to satisfy each credit requirement. The Code covers 9 areas of environmentally sustainable development, namely: • Energy/CO2 • Water • Materials • Surface Water Runoff • Waste • Pollution • Health and Wellbeing • Management • Ecology There are minimum mandatory standards for Energy/Co2, Water Consumption, Waste, Surface Water Run-off and Materials at Level 1. There are further minimum mandatory standards for Water Consumption at levels 3 and 5. Energy/CO2 has mandatory APPENDIX 1: GUIDANCE: CODE FOR SUSTAINABLE HOMES minimum standards at each of the levels culminating in level 6 which requires “carbon neutral” development. Lifetime Homes compliance is mandatory at level 6 The BRE audits the assessments and awards a certificate according to the final point score. Seven levels are possible (see table 1): RATING Minimum Score Required (%) FAIL < 36 Level 2 36 Level 2 48 Level 3 57 Level 4 68 Level 5 84 Level 6 90 Table 1: Code FSH Ratings Certification is compulsory at both the design stage (interim certificate) and at the post construction review stage (final certificate). A certificate is issued for each individual dwelling rather than for the whole development. Dwellings can be grouped into ‘Code Dwelling Types’ that share the same features and hence receive the same credits to save unnecessary repetition. For more general information about the Code and finding an Assessor refer to the BRE website, link below: The Code for Sustainable Homes, Technical Guide, published by DCLG (October 2008), can be found on the following link: http://www.planningportal.gov.uk/uploads/code_for_sustai nable_homes_techguide.pdf The Code Technical Guide, describes the aim of each category, the number of credits to achieve for each category and whether they are mandatory or optional. It explains the assessment criteria, lists the information that the BRE licensed Assessor will require from the development to demonstrate compliance and describes the assessment methodology for the design stage and post-construction stage and calculation procedures. 2 APPENDIX 1: GUIDANCE: BREEAM BREEAM For ‘Multi-residential’ (institutional accommodation such as student halls of residence or sheletered housing for the elderly) and ‘Non-residential’ devlopment (all other building uses such as offices, retail buildings, schools, industrial buildings etc.) The Building Research Establishment Environmental Assessment Method (BREEAM) is an independent appraisal method to certify the environmental performance of a building. BREEAM Buildings can be used to assess the environmental performance of any type of building (new and existing). Standard versions exist for common building types and less common building types can be assessed against tailored criteria under the Bespoke BREEAM version. BREEAM covers 8 areas of environmentally sustainable development, namely: • Management • Health and Wellbeing • Energy • Transport • Water • Materials and Waste • Land Use and Ecology • Pollution The issues within these areas vary according to the specific assessment model being used but there are a lot of issues in common. One aspect that is strikingly different from the Code for Sustainable Homes (see below) is the BREEAM credits for access to the site, particularly for non-car users and its location in relation to key facilities. To achieve a BREEAM rating, the minimum percentage score (see table 2) must be achieved and the minimum standards (i.e. number of credits achieved) applicable to that rating level complied with. 3 APPENDIX 1: GUIDANCE: BREEAM BREEAM Rating/ Mininum number of credits BREEAM Issue PASS GOOD VERY GOOD EXCELLENT OUTSTANDING Man 1 - Commissioning 1 1 1 1 2 Man 2 - Considerate Constructors 1 2 Man 4 - Building user guide 1 1 Man 9 - Publication of building information (BREEAM 1 Education only) Man 10 - Development as a learning resource 1 (BREEAM Education only) Hea 4 - High frequency lighting 1 1 1 1 1 Hea 12 - Microbial contamination 1 1 1 1 1 Ene 1 - Reduction of CO2 emissions 6 10 Ene 2 - Sub-metering of substantial energy uses 1 1 1 Ene 5 - Low or zero carbon technologies 1 1 Wat 1 - Water consumption 1 1 1 2 Wat 2 - Water meter 1 1 1 1 Wst 3 - Storage of recyclable waste 1 1 LE 4 - Mitigating ecological impact 1 1 1 Table 2: Minimum BREEAM standards Each development needs to be registered with the BRE by a BRE- licensed Assessor, who is employed by the developer. The development is assessed by the Assessor who awards credits when sufficient documentary proof has been supplied to satisfy each credit requirement. The BRE audits the assessments and awards a certificate according to the final point score. Five levels are possible (see table 3): RATING Minimum Score Required (%) UNCLASSIFIED <30 PASS ≥30 GOOD ≥45 VERY GOOD ≥55 EXCELLENT ≥70 OUTSTANDING ≥85 Table 3: BREEAM Ratings 4 APPENDIX 1: GUIDANCE: BREEAM Certification is compulsory at the design stage and is optional at the post construction review stage. A certificate is issued for the whole development rather than for individual buildings. More information including pre-assessment estimators and technical guides for each of the BREEAM assessments can be found on the following website: http://www.breeam.org/ The current models of BREEAM Assessment available are shown in the table 4 below. BREEAM: Healthcare BREEAM Healthcare can be used to assess all healthcare buildings containing medical facilities, and at different stages of their lifecycle. An additional tool BREEAM Healthcare XB also offers a solution for existing buildings in operation. BREEAM: Industrial BREEAM Industrial can assess storage & distribution, light industrial units, factories and workshops at the design stage and post construction. BREEAM: Multi-residential BREEAM Multi-Residential can assess student halls of residence, sheltered housing for the elderly, supported housing and hostel type accommodation at the design stage and post construction. BREEAM: Prisons BREEAM Prisons can assess high and standard security prisons, young offenders institutions, local prisons and women's prisons at the design stage and post construction. BREEAM: Offices BREEAM Offices can assess new build or major refurbishment and existing offices, at the design stage, post construction and in use. 5 APPENDIX 1: GUIDANCE: BREEAM BREEAM: Retail BREEAM Retail can assess new build or major refurbishment, post construction, tenant fit-out, existing (occupied), management and operation. BREEAM: Education BREEAM Education can assess new schools, major refurbishment projects Table 4: The current BREEAM Assessment Models relevant to this document © Copyright Building Research Establishment Ltd 2008 6 APPENDIX 1: GUIDANCE: 1.1 GENERAL SUSTAINABLE DEVELOPMENT 1.0 GENERAL SUSTAINABLE DEVELOPMENT 1.1 Minimum Code For Sustainable Homes and BREEAM Requirements Certification under the Code FSH and BREEAM provides a good indication of a certain level of sustainable development over a broad range of sustainable measures. Where the Council has more specific requirements these may be found within the detail of the assessment methods (specific credits required for a particular issue) or are requirements not specifically covered by the Code FSH or BREEAM. These specific issues are covered in subsequent Essential Requirements in this document. The general sustainable development requirement needs to escalate over the next decade to keep pace with expected Building Regulations changes and the target for Zero Carbon Homes by 2016. The development industry also needs some time to employ new design strategies and use new technologies and materials before the top levels of the assessment methods are required for all development. Policy Context (See Appendix 2) • South East Plan Policies SH8 (iv); CC1; CC2; CC4 • PUSH Planning Policy Framework • Eastleigh Local Plan Policies 37.ES; 20.CO; 25.NC; 26.NC; 28.ES; 33.ES; 36.ES; 38.ES; 45.ES; 59.BE. 7 APPENDIX 1: GUIDANCE: 1.1 GENERAL SUSTAINABLE DEVELOPMENT Essential Requirement ESD 1 The Council requires all residential development of 10 dwellings or more to: • Achieve Level 3 of the Code up to the end of 2010* The Council requires all residential development to: • • Achieve Level 3 of the Code from January 2011 up to the end of 2011* Achieve Level 4 of the Code from January 2012* Achieve Level 5 of the Code from January 2014* • Achieve Level 6 of the Code from January 2016* The Council requires all non-residential and multi-residential development above 1000 sq m of external floor space to: • Achieve BREEAM level “very good” up to the end of 2010* The Council requires all
Recommended publications
  • The Development of Robust Details for Sound Insulation in New Build Attached Dwellings
    The development of robust details for sound insulation in new build attached dwellings Received: 30th September, 2005 Sean Smith BSc, PhD, MIOA is RC UK Research Fellow and Principal Research Fellow at the Building Performance Centre, School of the Built Environment, Napier University, External Technical Advisor to Robust Details Ltd and joint project manager of the RSD project. He is also Senior Acoustic Consultant with the Robin Mackenzie Partnership. Dave Baker MRICS, MCIOB, MBEng is CEO of Robust Details Ltd and former Technical Director of the RSD project and House Builders Federation. Richard Mackenzie BSc, MIOA, MInstSCE is Lead Acoustic Consultant with the Robin Mackenzie Partnership and joint project manager of the RSD project. John B. Wood BSc, DA is Lecturer in Architectural Technology at the School of the Built Environment, Napier University and designer of the RSD project submission. Philip Dunbavin MSc, FIOA, MSEE, MIOSH, MInstSCE is Managing Director and Principal Acoustic Consultant with the PDA Group and Chairman of the RD Inspectors. David Panter BSc, MIQA is Operations Manager with Robust Details Ltd. Abstract This paper outlines the background, process and system approach towards the development of robust details (RD) for sound insulation for new build dwellings in England and Wales. Part 1 outlines the initial Robust Standard Details project and its framework, Part 2 describes the structure and operation of the RD scheme for Building Regulation E1 and Part 3 provides feedback on the first operating year of the scheme. In addition, comparisons are made between previous performance levels and constructions used for Part E (1992) relative to the RD approach using recent data feedback from random site inspections and testing.
    [Show full text]
  • The Housing Forum December 2017
    A REPORT FROM THE HOUSING FORUM DECEMBER 2017 Building Homes Better The quality challenge SUPPORTED BY: AMCM GROUP LTD | BLP INSURANCE | HUNTERS Working with NHBC About this report Over the course of 2017, a cross-sector group Report sponsors of members of The Housing Forum formed a working group chaired by Rory Bergin, HTA Design, to investigate how building better quality homes can be delivered to improve the experience of those buying and renting them. We decided to limit our remit to the quality of individual homes while fully acknowledging that good place making and appropriate and sustainable infrastructure are essential to the creation of good living environments. We have looked into the points of interaction between customers and the housing industry and found systemic failures to provide quality outcomes, either in terms of design quality or customer satisfaction. This report is intended to highlight where those problems occur, and what we think can be done about them to achieve a positive change for quality. Contents Foreword Rory Bergin Working Group Chair 3 Executive summary 4 PART ONE: POLICY AND PRACTICE 6 PART TWO: NEW IDEAS AND CASE STUDIES 16 Fostering a quality culture 6 Selecting products to improve the experience 16 of residents Improving the experience of tenants and buyers 8 Case study: London Borough of Newham 18 Pre-planning, regulation and design quality 10 Case study: Cumbrian Homes 20 Procurement and construction 12 How a smart regulatory framework enabled a high 22 performing industry friendly solution Harnessing
    [Show full text]
  • Management of the Firm
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Central Archive at the University of Reading NEW GOVERNANCE APPROACHES TO ENVIRONMENTAL REGULATION: AN EXAMPLE OF THE CODE FOR SUSTAINABLE HOMES (CHS) Shu-Ling Lu1 and Martin G. Sexton School of Construction Management and Engineering, University of Reading, Reading, UK. Environmental policy in the United Kingdom (UK) is witnessing a shift from command-and-control approaches towards more innovation-orientated environmental governance arrangements. These governance approaches are required which create institutions which support actors within a domain for learning not only about policy options, but also about their own interests and preferences. The need for construction actors to understand, engage and influence this process is critical to establishing policies which support innovation that satisfies each constituent’s needs. This capacity is particularly salient in an era where the expanding raft of environmental regulation is ushering in system-wide innovation in the construction sector. In this paper, the Code for Sustainable Homes (the Code) in the UK is used to demonstrate the emergence and operation of these new governance arrangements. The Code sets out a significant innovation challenge for the house-building sector with, for example, a requirement that all new houses must be zero-carbon by 2016. Drawing upon boundary organisation theory, the journey from the Code as a government aspiration, to the Code as a catalyst for the formation of the Zero Carbon Hub, a new institution, is traced and discussed. The case study reveals that the ZCH has demonstrated boundary organisation properties in its ability to be flexible to the needs and constraints of its constituent actors, yet robust enough to maintain and promote a common identity across regulation and industry boundaries.
    [Show full text]
  • Model Planning Conditions for the Code for Sustainable Homes and Breeam 14
    1 Contents ONE Introduction 1 BACKGROUND 1 WHAT IS SUSTAINABLE DESIGN AND CONSTRUCTION? 2 CLIMATE CHANGE SPD 2 PURPOSE OF GUIDANCE NOTE 1: SUSTAINABLE BUILDING STANDARDS 2 CONTENTS 2 TWO Policy Context 3 NATIONAL CONTEXT 3 LONDON CONTEXT 3 BOROUGH CONTEXT 4 THREE Code for Sustainable Homes 5 BACKGROUND 5 PLANNING POLICY REQUIREMENTS 5 PLANNING GUIDELINES 5 Guideline SB1: Pre- Assessment Report (Code for Sustainable Homes) 6 Guideline SB2: Design Stage Assessment (Code for Sustainable Homes) 7 Guideline SB3: Post Construction Stage Assessment (Code for Sustainable Homes) 8 FOUR ‘BREEAM’ Sustainability Ratings (Non-Residential Developments) 9 BACKGROUND 9 PLANNING POLICY REQUIREMENTS 9 PLANNING GUIDELINES 10 Guideline SB4: Pre- Assessment Report (BREEAM) 10 Guideline SB5: Design Stage Assessment (BREEAM) 10 Guideline SB6: Post Construction Stage Assessment (BREEAM) 11 FIVE Sustainable Design and Construction Statements 12 BACKGROUND 12 PLANNING POLICY REQUIREMENTS 12 PLANNING GUIDELINE 12 Guideline SB7: Sustainable Design and Construction Statements 12 SIX Model Planning Conditions 13 BACKGROUND 13 PLANNING GUIDELINE 13 Guideline SB8: Use of Planning Conditions (CSH/ BREEAM) 13 MODEL PLANNING CONDITIONS FOR THE CODE FOR SUSTAINABLE HOMES AND BREEAM 14 SEVEN Development Management Flowchart: Code for Sustainable Homes 15 and BREEAM 2 ONE Introduction Background 1.1 In 2009, Sutton became the first Council in the UK to commit to being a ‘One Planet Living' (OPL) Borough. This seeks to reduce our environmental footprint to acceptable levels based on the recognition that if everyone in the world lived as we do in Sutton, we would need almost three planets’ worth of resources to maintain our current levels of consumption.
    [Show full text]
  • Code for Sustainable Homes: Technical Guide
    Code for Sustainable Homes Technical Guide www.communities.gov.uk community, opportunity, prosperity Code for Sustainable Homes Technical Guide March 2007 Department for Communities and Local Government: London Acknowledgements This Technical Guide has been drafted by the BREEAM Centre at the Building Research Establishment under contract to Communites and Local Government Department for Communities and Local Government Eland House Bressenden Place London SW1E 5DU Telephone: 020 7944 4400 Website: www.communities.gov.uk © Crown Copyright 2007 Copyright in the typographical arrangement rests with the Crown. This publication, excluding logos, may be reproduced free of charge in any format or medium for research, private study or for internal circulation within an organisation. This is subject to it being reproduced accurately and not used in a misleading context. The material must be acknowledged as Crown Copyright and the title of the publication specified. Any other use of the contents of this publication would require a copyright licence. Please apply for a Click-Use Licence for core material at www.opsi.gov.uk/click-use/system/online/pLogin.asp or by writing to the Office of Public Sector Information, Information Policy Team, St Clements House, 2-16 Colegate, Norwich NR3 1BQ. Fax: 01603 723000 or email: HMSOlicensing@cabinet-office.x.gsi.gov.uk. If you require this publication in an alternative format please email [email protected] Communities and Local Government Publications PO Box 236 Wetherby West Yorkshire LS23 7NB Tel: 0870 1226 236 Fax: 0870 1226 237 Textphone: 0870 1207 405 Email: [email protected] or online via the Communities and Local Government website: www.communities.gov.uk March 2007 Product Code 06BD04486 Foreword We must act on climate change.
    [Show full text]
  • Technical Extra
    Technical Extra February 2015 | Issue 17 In this issue: NHBC STANDARDS Minimum foundation depths in clay soils page 3 Ironmongery for windows and doors page 4 REGULATION AND COMPLIANCE Update on air-tightness testing page 6 Ensuring adequate ventilation to naturally-ventilated dwellings page 8 NHBC updated guidance in respect of guarding to openable windows with low cill heights page 10 Design and use of autoclaved aerated concrete masonry units page 14 CE marking for steelwork fabrications page 16 GUIDANCE AND GOOD PRACTICE Pre-start meetings and risk guides page 18 Provision of fire protection to proprietary dummy chimneys over party walls page 19 robustdetails® animated training videos page 20 NHBC Foundation page 22 Provision of weep holes and weep vents in masonry walls page 24 INFORMATION AND SUPPORT Technical news Page 25 Information and support page 26 Foreword Welcome to Technical Extra 17 Pre-start meetings between site teams and NHBC building inspectors provide an opportunity to identify and consider specific issues and risks associated with the site and build. Whilst not uncommon in the past, we’ve developed a more robust framework for these discussions – read the article in Guidance and good practice for more details on the benefits of these meetings. Readers might be surprised to learn that 15% of the defect-related contacts NHBC receives relate to windows and doors. Ironmongery dominates, with issues relating to handles, locks and hinges accounting for almost half. Comments recorded on customer satisfaction surveys also highlight similar issues; the article ‘Ironmongery for windows and doors’ provides more information. As methods of making homes more airtight have been designed, and construction practices have improved, the level of airtightness you can hope to achieve has also progressed.
    [Show full text]
  • Planning Rebuttal to Lpa's Proof of Evidence
    TOWN AND COUNTRY PLANNING ACT 1990 SECTION 78 APPEAL BY THE WELLINGTON PUB COMPANY PLC PROOF OF EVIDENCE – PLANNING REBUTTAL TO LPA’S PROOF OF EVIDENCE MARK BATCHELOR BSc (Hons), MSc, MRTPI THE WHITE HART, 184 NEW CROSS ROAD, LONDON, SE14 5AA PINS REF: APP/C5690/W/19/324119 LPA REF: DC/18/106613 3 MARCH 2020 1 Rebuttal of LPA’s Planning Evidence | The White Hart, 184 New Cross Road, SE14 5AA Report Control Project: The White Hart Client: The Wellington Pub Company Reference: 17.5061 File Origin: J:\17.5061\4 Boyer Planning\4.02 Reports\Appeal Primary Author DT Checked By: MB Issue Date Status Checked By 1 03/03/2020 Final MB 1. PLANNING REBUTTAL TO LPA’S PROOF OF EVIDENCE 1.1 This rebuttal statement should be read in accordance with my initial proof of evidence dated 18 February 2020 and submitted to PINS on the same date. It seeks to address and clarify the statements made in the Council’s Planning Proof of Evidence (PoE). It will primarily comment on the Agent of Change principle, where the Council, in paragraph 10.4 of their PoE, consider this to be relevant in this instance by virtue of the necessity for conditions to be imposed on the public house to prevent adverse noise and disturbance to future residents. Intend to Publish London Plan policy D13 (Agent of Change), in line with NPPF paragraph 182, states that development should be designed to ensure that established noise and other nuisance-generating uses can continue to operate or grow without having unreasonable restrictions placed on them.
    [Show full text]
  • Defining a Fabric Energy Efficiency Standard for Zero Carbon Homes
    DEFINING A FABRIC ENERGY EFFICIENCY STANDARD FOR ZERO CARBON HOMES Executive Summary of Task Group Recommendations November 2009 FACILITATING THE MAINSTREAM DELIVERY OF LOW AND ZERO CARBON HOMES Zero Carbon Hub Acknowledgements The full report ‘Defining a Fabric Energy The Zero Carbon Hub is very grateful to the Efficiency Standard for Zero Carbon Homes’ is following organisations for their involvement available as a PDF download from and contributions in developing these www.zerocarbonhub.org recommendations. Association for Environment Conscious Building (AECB) Aecom Anser Project Managers London Office Barratt Developments PLC 62-68 Rosebery Avenue British Electrotechnical and Allied Manufacturers' London EC1R 4RR Association (BEAMA) Building Research Establishment (BRE) Milton Keynes Office Building Regulations Advisory Committee (BRAC) NHBC House, Davy Avenue Construction Products Association (CPA) Milton Keynes MK5 8FP Countryside Properties PLC Crest Nicholson PLC T 0845 888 7620 Davis Langdon F 0871 813 0569 Energy Saving Trust (EST) [email protected] Fairview New Homes Ltd. Federation of Environmental Trade Associations www.zerocarbonhub.org (FETA) November 2009 Federation of Master Builders (FMB) Reprinted January 2010 Fulcrum Consulting Reprinted with minor changes March 2010 Good Homes Alliance (GHA) Heating and Hotwater Industry Council (HHIC) Heatrae Sadia Home Builders Federation (HBF) nd Homes and Communities Agency (HCA) All costs based on 2 quarter 2009 information and do not take account of: Hot Water Association
    [Show full text]
  • 2012 Consultation on Changes to the Building Regulations in Wales Part L (Conservation of Fuel and Power)
    2012 Consultation on Changes to the Building Regulations in Wales Part L (Conservation of fuel and power) Consultation – summary of responses Part 4 #03 Ian Whittaker - UK Registered Architect #17 Gordon Russell - GR Architect #26 Robust Details Limited #34 RTPI Cymru #52 Friends of the Earth Cymru #72 Community Housing Cymru Group #79 Institute of Historic Building Conservation #81 Llanmoor Development Co Limited #84 CBI Wales #90 EAMA The UK zero carbon house myth. What is the definition of a zero-carbon home? 'A home that produces zero or even negative CO2 emissions by maximising the use of energy efficiency and renewable energy.' Guardian 2009 'A zero carbon home is one that generates as much power as it uses over the course of a year and therefore has net zero carbon dioxide emissions.' Tree hugger 2009 A building can be considered fully ‘zero carbon’ when there is no net emission of carbon dioxide (CO2) arising from the energy use within the building. This includes space heating, water heating, lighting, appliances and so on. www.idea.gov.uk The government has set the following targets for zero-carbon buildings: All new-build homes in England and Wales to be ‘zero carbon’ by 2016 . All new schools to be zero carbon by 2010 . All new public sector buildings to be zero carbon by 2018 . All new non- domestic buildings to be zero carbon from 2019. (Local Government Improvement and Development 2011) What is wrong with the current definition of a zero carbon home ? The definitions all neglect to allow for :- The energy used in extracting the materials for the home.
    [Show full text]
  • Council Meeting
    COUNCIL MEETING Date: 19 July 2010 Venue: East Northamptonshire House, Cedar Drive, Thrapston Time: 7.30 pm Present: Councillors:- Sue Homer (Chairman) Andy Mercer (Leader of the Council) David Bateman Steven North David Brackenbury Brian Northall Pauline Bradberry JP Sarah Peacock Albert Campbell Ron Pinnock Richard Gell Roger Powell Roger Glithero JP Rupert Reichhold Glenvil Greenwood-Smith John Richardson MBE Philip Hardcastle Anna Sauntson Glenn Harwood MBE Ron Silver Marian Hollomon Robin Underwood Sean Lever Pam Whiting Richard Lewis Clive Wood Peter MacGovern Also Present: Graham Blagden (Chairman of the Standards Board) Father Grant Brockhouse, St. Marys Church, Higham Ferrers 100. PRAYERS Before the commencement of business, at the invitation of the Chairman, prayers were conducted by Father Grant Brockhouse of St. Mary’s Church, Higham Ferrers. 101. APOLOGIES FOR ABSENCE Councillors Peter Bedford, Tony Boto, Sylvia and Dudley Hughes, Barbara Jenney, Eloise Lucille Gill Mercer, Phillip Stearn and Colin Wright sent their apologies. 102. MINUTES The minutes of the Annual Meeting held on 12 May 2010 were approved and signed by the Chairman. 103. DECLARATIONS OF INTEREST Councillor Roger Powell declared a personal interest in item 11(b) (Manor Park, Rushden) as a resident of Rushden. The following Members declared a personal and prejudicial interest in the items indicated and were not present during the discussion and voting on these items:- Council Meeting – 19 July 2010 Page 109 Members/Co-opted Members Item Nature of Interest Mr Graham Blagden 10(b) Person the subject of the appointment Councillors Marian Hollomon, 11(b) Members of Rushden Town Council Richard Lewis, Andy Mercer, Steven North, Sarah Peacock, Ron Pinnock, Robin Underwood and Clive Wood 104.
    [Show full text]
  • RD110 ROBUST DETAILS CERTIFICATION SCHEME PLOT REGISTRATION APPLICATION FORM for New Build Attached Dwellings in England, Wales, Scotland and Northern Ireland
    Robust Details Limited, Block E, Bletchley Park Science and Innovation Centre, Milton Keynes, MK3 6EB Tel: 03300 882 141 Fax: 01908 363433 www.robustdetails.com RD110 ROBUST DETAILS CERTIFICATION SCHEME PLOT REGISTRATION APPLICATION FORM For new build attached dwellings in England, wales, Scotland and Northern Ireland. To be completed by the Developer and submitted before work starts on the dwellings. MAIN CONTACT DETAILS (developer or duly appointed representative and to whom all plot registration documents will be sent by email) Name Company Address Postcode Telephone No Email Please indicate your role: Builder Developer only Designer Other (please specify) BUILDER CONTACT DETAILS (details of the builder responsible for the construction of the robust details) Builder Contact Builder Company Builder Address Postcode SITE DETAILS (details of the site where the robust details are to be constructed) Site Name Site Address Postcode BUILDING CONTROL BODy (NAME) NAME OF NEw HOME wARRANTy PROvIDER IMPORTANT INFORMATION - MUST BE COMPLETED DEvELOPER OF THE SITE (the person named on the building control application) Name Company Name Address Postcode Date By signing this form, you confirm that you have read, understood and agree to the current version of Robust Details Limited’s terms and conditions for plot registrations which can be found in the Support/Downloads area of our web site at www.robustdetails.com CODE FOR SUSTAINABLE HOMES (Do you yES DEvELOPER’S SIGNATURE intend to use Robust Details to gain credits NO IMPORTANT INFORMATION - MUST
    [Show full text]
  • Changes Made to the 2003 Edition by Incorporating Amendments 2004*
    Main changes made to the 2003 edition by incorporating amendments 2004* This edition of Approved Document E, Resistance to the passage of sound, supersedes the original 2003 edition by incorporating the changes made by Amendments 2004 (issued in June 2004) to Approved Document E 2003. Minor corrections and clarifications have also been made, but there is no new information. Part E in Schedule 1 to the Building Regulations 2000 (as amended) came into force on 1 July 2003. At the same time a new regulation 20A was introduced into the Building Regulations 2000, and a new regulation 12A was introduced into the Building (Approved Inspector etc) Regulations 2000. Regulations 20A and 12A introduced pre-completion testing for sound insulation as a means of demonstrating compliance. Pre-completion testing has applied to rooms for residential purposes, houses and flats formed by conversion of other buildings since 1 July 2003, and to new houses and flats from 1 July 2004. Also, from 1 July 2004, use of robust details in new houses and flats has been accepted as an alternative to pre-completion testing. Robust details are high performance separating wall and floor constructions (with associated construction details) that are expected to be sufficiently reliable not to need the check provided by pre-completion testing. The introduction of robust details has necessitated the amendment of regulations 20A and 12A. The amendments have been made by the Building (Amendment) Regulations 2004 and the Building (Approved Inspector etc) (Amendment) Regulations 2004. Regulations 20A and 12A were reproduced in Approved Document E, original 2003 Edition; and so amended versions have been included in this edition.
    [Show full text]