Pitot Tube NPL Type (L / Straight)

Total Page:16

File Type:pdf, Size:1020Kb

Pitot Tube NPL Type (L / Straight) Pitot tube NPL type (L / straight) PRESENTATION KIMO offers a broad range of Pitot tubes of great quality and accuracy realised according to the NF X 10-112 norm. The KIMO Pitot tubes, connected to a differential column of liquid manometer, with needle or electronic, enable to measure the dynamic pression of a fluid in movement in a pipe and determine its speed in m/s and its flow in m3/h. The Pitot tubes are used in climatic engineering, ventilation, dust-removal With built-in temperature probe and pneumatic transport. They are Pitot tube straight type Pitot tube L type with particularly adapted for measurement Pitot tube L type and straight type with K TC in warm air, charged with particles and Pitot tubes with ellipsoidal top. K TC A total pressure port and six holes Pitot tubes with ellipsoidal top. for high speed. of static pressure. A total pressure port and six holes of It enables to carry out Body in full stainless steel. static pressure. measurement directly by K thermocouple probe lined immersing the tube in the air- integrated with connecting cable of diffusing equipment. 1.5 meter long. Diameter and sizes : same as the Body in full stainless steel. NPL curved Pitot. FEATURES Model AFNOR NF Coefficient 1,0015 ±0,01 Material Stainless steel 316 L Measurement range 0 to 100 m/s Temperature of use from 0 to 600 °C in standard and until 1000 °C in option Static pressure 2 bar maximum in static, hereafter on request Global accuracy of the measurement Better than 1% for an alignment in relation to the flow system axis of the fluid of ±10°. AFNOR NFX10-112. Annex of the 77.09.14 Standards This standard is in accordance with the international standard ISO 3966. Static pressure output pressure Static PRESENTATION OF THE OF RANGE THE PRESENTATION SIZES Diameter Total pressure port Ø14 mm Ø14 mm Ø12 Ø8 mm Ø8 mm Ø6 mm Ø3 Nez Pitot tubes L L tubes Pitot E Reference L type L Reference TPL-14-3000 TPL-14-2500 TPL-12-2000 TPL-12-1500 TPL-08-1250 TPL-08-1000 TPL-06-800 TPL-06-500 TPL-06-300 TPL-03-300 TPL-03-200 TPL-03-100 output pressure Total Pitot tube Ø 14 tubemm Ø Pitot 12 tubemm Ø Pitot Pitot tube L Pitot tube Ø 8 mm 8 Ø tube Pitot mm 6 Ø tube Pitot mm 3 Ø tube Pitot 6 holes of static pressure Antenna F: type and and type D Reference straight straight type Reference Ø6 ØC type TPL-D-14-3000 TPL-D-12-2000 TPL-D-12-1500 TPL-D-08-1250 TPL-D-08-1000 TPL-D-06-800 TPL-D-06-500 TPL-D-06-300 TPL-D-03-300 TPL-D-03-200 TPL-D-03-100 straight NOMINAL Ø Ø6 25 25 25 25 17 A - 50 50 40 40 32 B type A B Lg: useful length of the shaft – (see table below) ØC 16 16 10 10 10 70 70 50 40 30 3000 mm 3000 mm 2500 mm 2000 mm 1500 mm 1250 mm 1000 D 800 mm 800 mm 500 mm 300 mm 200 mm 100 Length 300mm 112 96 64 48 25 E Pitot tubes L tubes Pitot Static pressureoutput Static 224 192 128 96 48 Diameter Ø14 mm Ø14 mm Ø12 F Total pressure port Ø8 mm Ø8 mm Ø6 mm Ø3 Nose 42 36 24 18 9 R type and and type Reference L type L Reference Pitot tube L E TPL-14-3000-T TPL-14-2500-T TPL-12-2000-T TPL-12-1500-T TPL-08-1250-T TPL-08-1000-T TPL-06-800-T TPL-06-500-T TPL-06-300-T TPL-03-300-T TPL-03-200-T TPL-03-100-T output pressure Total F : Antenna F : document are specifiedmm. in All dimensions and ratings ofthis straight 6 holes of static pressure type type with Reference straight type straight Reference D type with type TPL-D-12-2000-T TPL-D-12-1500-T TPL-D-08-1250-T TPL-D-08-1000-T TPL-D-06-800-T TPL-D-06-500-T TPL-D-06-300-T TPL-D-03-300-T TPL-D-03-200-T TPL-D-03-100-T Ø6 ØC Ø NOMINAL Ø6 - - K thermocouple K thermocouple A B Lg:useful length of the shaft – (see table below) 3000 mm 3000 mm 2500 mm 2000 mm 1500 mm 1250 mm 1000 800 mm 800 mm 500 mm 300 mm 300 mm 200 mm 100 Length K female miniature thermocouple connector WORKING PRINCIPLE The Pitot tube is introduced perpendicularly in the pipe by pre-determined points (cf. ''Measurement''). The antenna composed of an ellipsoidal nose (bow) maintained in parallel and in front of the flow to control. The total pressure (+) is picked up by the bow and is connected to the + sign of the manometer. The static pressure (-) picked up by the small holes located around the antenna is connected to the – sign of the manometer. The connecting cable of the K thermocouple is connected to the input K of the manometer (for the Pitot tube type L with K TC). The device then indicates the dynamic pressure, sometimes called speed pressure. The dynamic pressure corresponds to the difference between total pressure and static pressure : Dp = Tp-Sp APPLICATION Total pressure (Tp) Static pressure (Sp) Dynamic pressure = Tp - Sp Example above : The Kimo manometer (portable or transmitter) directly indicates the speed in m/s. Alarm Alarm Visualise Visualise GTC Record Operate Record GTC Analyse GTC Record Analyse GTC Analyse Graph in direct Graph in direct Low differential pressure Low differential pressure transmitter Multifunction intelligent transmitter with digital display CP210 and SQR/3 portable C310 or CA 310 with SPI 2 – AMI 310 100,500,1000, 10000 and SQR/3 ACCESSORIES OPTIONS MEASUREMENT Forevery other cases, offersspecialKIMO realisations. machining. us,Consult weintervene on plansstudy, ● ● ● ● ● ● ● ● ● ● ● ● ● according to Log-Tchebychev (seemeasurement scheme above). according to Log-Tchebychev Average (A) of several ● measurements of punctual velocity ● Transport case type VTP Pitottubes:for Transport Tubes J.T.C J.Y.C 555 F/F Caps Stopper cap Extensioncable Sliding connections flange Mounting Gland Flow = Velocity Flowcalculating: surface automatically is adjustable. N.B: inthe electronic devices, the rectangularsheath in m² Surface TIG Welding Graduation Flowmeasurement Measurementpunctualof velocity V : junctions in T for a tube: junctionsT 5in Ø (bag x mm 8 of10) : junctions in Y for a: junctionsY tube in : : bag of10 pieces = in plated the(for brass installationof Pitot tubesfor fixed station) : : : spherical valve ball female /female : : C surfaceof theor circular ➔ ➔ ➔ ➔ ➔ F Pitot tube L : C C P Θ √ O F (mm) with onred mark (mm) the shaft, requeston for a use up to1000°C (except Pitot tube : : in With 810X 100mm, length500mm, max. Ø6 1210X 320 mm, length 1000mm, max. Cristal tubeCristal REF(5 C-58-1 x mm) 8 silicone REF (4 x SB-47-17mm) Transparent siliconeBlack (4 REFSN-47-1x 7 mm) given temperature(°C) : 2 given atmospheric pressure (Pa) caoutchouc: bagof pieces10 A coefficient of thedevice flow element x Surface x 3600 Δ for Kthermocouple 1 class ρ stainless steeland cast iron P with steelstainless turn or PTFE F = 1.0015 ρ Ø 58Ø (bagx mm of10) = 287.1 × ( Θ P V Surface: inm Flow: m in O A + : m/s : in 273.15 With Ø8 3 ) /h Ø 2 3) H H Length Diameter 0,939 0,968 0,863 0,765 0,688 0,563 0,437 0,312 0,235 0,061 0,137 0,032 0,074 0,288 c y b e h c T - g o L i o p 3 n i v e h s t n 0,5 0,712 FT_ang – Pitot-tube-L – 12/05/17 – RCS (24)Périgueux 349 282 095 -Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice. 0,928.
Recommended publications
  • Pitot-Static System Blockage Effects on Airspeed Indicator
    The Dramatic Effects of Pitot-Static System Blockages and Failures by Luiz Roberto Monteiro de Oliveira . Table of Contents I ‐ Introduction…………………………………………………………………………………………………………….1 II ‐ Pitot‐Static Instruments…………………………………………………………………………………………..3 III ‐ Blockage Scenarios – Description……………………………..…………………………………….…..…11 IV ‐ Examples of the Blockage Scenarios…………………..……………………………………………….…15 V ‐ Disclaimer………………………………………………………………………………………………………………50 VI ‐ References…………………………………………………………………………………………….…..……..……51 Please also review and understand the disclaimer found at the end of the article before applying the information contained herein. I - Introduction This article takes a comprehensive look into Pitot-static system blockages and failures. These typically affect the airspeed indicator (ASI), vertical speed indicator (VSI) and altimeter. They can also affect the autopilot auto-throttle and other equipment that relies on airspeed and altitude information. There have been several commercial flights, more recently Air France's flight 447, whose crash could have been due, in part, to Pitot-static system issues and pilot reaction. It is plausible that the pilot at the controls could have become confused with the erroneous instrument readings of the airspeed and have unknowingly flown the aircraft out of control resulting in the crash. The goal of this article is to help remove or reduce, through knowledge, the likelihood of at least this one link in the chain of problems that can lead to accidents. Table 1 below is provided to summarize
    [Show full text]
  • Sept. 12, 1950 W
    Sept. 12, 1950 W. ANGST 2,522,337 MACH METER Filed Dec. 9, 1944 2 Sheets-Sheet. INVENTOR. M/2 2.7aar alwg,57. A77OAMA). Sept. 12, 1950 W. ANGST 2,522,337 MACH METER Filed Dec. 9, 1944 2. Sheets-Sheet 2 N 2 2 %/ NYSASSESSN S2,222,W N N22N \ As I, mtRumaIII-m- III It's EARAs i RNSITIE, 2 72/ INVENTOR, M247 aeawosz. "/m2.ATTORNEY. Patented Sept. 12, 1950 2,522,337 UNITED STATES ; :PATENT OFFICE 2,522,337 MACH METER Walter Angst, Manhasset, N. Y., assignor to Square D Company, Detroit, Mich., a corpora tion of Michigan Application December 9, 1944, Serial No. 567,431 3 Claims. (Cl. 73-182). is 2 This invention relates to a Mach meter for air plurality of posts 8. Upon one of the posts 8 are craft for indicating the ratio of the true airspeed mounted a pair of serially connected aneroid cap of the craft to the speed of sound in the medium sules 9 and upon another of the posts 8 is in which the aircraft is traveling and the object mounted a diaphragm capsuler it. The aneroid of the invention is the provision of an instrument s: capsules 9 are sealed and the interior of the cas-l of this type for indicating the Mach number of an . ing is placed in communication with the static aircraft in fight. opening of a Pitot static tube through an opening The maximum safe Mach number of any air in the casing, not shown. The interior of the dia craft is the value of the ratio of true airspeed to phragm capsule is connected through the tub the speed of sound at which the laminar flow of ing 2 to the Pitot or pressure opening of the Pitot air over the wings fails and shock Waves are en static tube through the opening 3 in the back countered.
    [Show full text]
  • Aviation Occurrence No 200403238
    ATSB TRANSPORT SAFETY INVESTIGATION REPORT Aviation Occurrence Report – 200403238 / 200404436 Final Abnormal airspeed indications En route from/to Brisbane Qld 31 August 2004 / 9 November 2004 Bombardier Aerospace DHC8-315 VH-SBJ / VH-SBW ATSB TRANSPORT SAFETY INVESTIGATION REPORT Aviation Occurrence Report 200403238 / 200404436 Final Abnormal airspeed indications En route from/to Brisbane Qld 31 August 2004 / 9 November 2004 Bombardier Aerospace DHC8-315 VH-SBJ / VH-SBW Released in accordance with section 25 of the Transport Safety Investigation Act 2003 - i - Published by: Australian Transport Safety Bureau Postal address: PO Box 967, Civic Square ACT 2608 Office location: 15 Mort Street, Canberra City, Australian Capital Territory Telephone: 1800 621 372; from overseas + 61 2 6274 6590 Accident and serious incident notification: 1 800 011 034 (24 hours) Facsimile: 02 6274 6474; from overseas + 61 2 6274 6474 E-mail: [email protected] Internet: www.atsb.gov.au © Commonwealth of Australia 2007. This work is copyright. In the interests of enhancing the value of the information contained in this publication you may copy, download, display, print, reproduce and distribute this material in unaltered form (retaining this notice). However, copyright in the material obtained from non- Commonwealth agencies, private individuals or organisations, belongs to those agencies, individuals or organisations. Where you want to use their material you will need to contact them directly. Subject to the provisions of the Copyright Act 1968, you must not make any other use of the material in this publication unless you have the permission of the Australian Transport Safety Bureau. Please direct requests for further information or authorisation to: Commonwealth Copyright Administration, Copyright Law Branch Attorney-General’s Department, Robert Garran Offices, National Circuit, Barton ACT 2600 www.ag.gov.au/cca - ii - CONTENTS THE AUSTRALIAN TRANSPORT SAFETY BUREAU .................................
    [Show full text]
  • AIRSPEED INDICATORS - ALTIMETERS WINTER 3-INCH ALTIMETERS WINTER 2-1/4 INCH Standard Precision Altimeters 4 FGH 10
    AIRSPEED INDICATORS - ALTIMETERS WINTER 3-INCH ALTIMETERS WINTER 2-1/4 INCH Standard Precision Altimeters 4 FGH 10. AIRSPEED INDICATORS Airtight, black plastic housing. Connection This precision instrument is enclosed in a via hose from static pressure sensor to hose CM compact housing and operates by means of a connector on rear. Kollsman window with measuring tube. This ensures high accuracy millibar scale, reading from 940 to 1050 even at very low speeds. EBF-series airspeed millibars. See scale drawing for installation indicators are available with a pitot tube and dimensions. static pressure connection. Weight 0.330 kg. Linear scale The 4 FGH 10 altimeter can be fitted with a Description Part No. Price WP scale ring. Winter 2-1/4 ASI 8020 EBF Various 10-05625 $374.00 Range 360 Degree Dial Description Part No. Price Winter 2-1/4 ASI 8022 EBF Various 10-05627 $374.00 Winter 3 Altimeter 4 FGH 10 1000-20000 FT MB 10-05621 $1,202.00 Range 360 Degree Dial Winter 3 Altimeter 4 FGH 10 1000-20000 FT INHG 10-05622 $1,198.00 ME Winter 2-1/4 ASI 8026 EBF Various 10-05629 $455.00 Range 510 Degree Dial Winter 2-1/4” ASI 7 FMS 213 10-05908 $603.00 Range 0 To 100 Knot 360 Dial WINTER 2-1/4 INCH ALTIMETERS The pressure-sensitive measuring element is HA WINTER 3 INCH a diaphragm capsule (aneroid capsule) which AIRSPEED INDICATORS reacts to the effect of changing air pressure This precision instrument is enclosed in a com- as the aircraft changes altitude.
    [Show full text]
  • Richard Lancaster [email protected]
    Glider Instruments Richard Lancaster [email protected] ASK-21 glider outlines Copyright 1983 Alexander Schleicher GmbH & Co. All other content Copyright 2008 Richard Lancaster. The latest version of this document can be downloaded from: www.carrotworks.com [ Atmospheric pressure and altitude ] Atmospheric pressure is caused ➊ by the weight of the column of air above a given location. Space At sea level the overlying column of air exerts a force equivalent to 10 tonnes per square metre. ➋ The higher the altitude, the shorter the overlying column of air and 30,000ft hence the lower the weight of that 300mb column. Therefore: ➌ 18,000ft “Atmospheric pressure 505mb decreases with altitude.” 0ft At 18,000ft atmospheric pressure 1013mb is approximately half that at sea level. [ The altimeter ] [ Altimeter anatomy ] Linkages and gearing: Connect the aneroid capsule 0 to the display needle(s). Aneroid capsule: 9 1 A sealed copper and beryllium alloy capsule from which the air has 2 been removed. The capsule is springy Static pressure inlet and designed to compress as the 3 pressure around it increases and expand as it decreases. 6 4 5 Display needle(s) Enclosure: Airtight except for the static pressure inlet. Has a glass front through which display needle(s) can be viewed. [ Altimeter operation ] The altimeter's static 0 [ Sea level ] ➊ pressure inlet must be 9 1 Atmospheric pressure: exposed to air that is at local 1013mb atmospheric pressure. 2 Static pressure inlet The pressure of the air inside 3 ➋ the altimeter's casing will therefore equalise to local 6 4 atmospheric pressure via the 5 static pressure inlet.
    [Show full text]
  • Flight Instruments - Rev
    Flight Instruments - rev. 9/12/07 Ground Lesson: Flight Instruments Objectives: 1. to understand the flight instruments, and the systems that drive them 2. to understand the pitot static system, and possible erroneous behavior 3. to understand the gyroscopic instruments 4. to understand the magnetic instrument, and the short comings of the instrument Justification: 1. understanding of flight instruments is critical to evaluating proper response in case of failure 2. knowledge of flight instruments is required for the private pilot checkride. Schedule: Activity Est. Time Ground 1.0 Total 1.0 Elements Ground: • overview • pitot-static instruments • gyroscopic instruments • magnetic instrument Completion Standards: 1. when the student exhibits knowledge relating to flight instruments including their failure symptoms 1 of 3 Flight Instruments - rev. 9/12/07 Presentation Ground: pitot-static system 1. overview (1) pitot-static system uses ram- air and static air measurements to produce readings. (2) pressure and temperature effect the altimeter i. remember - “Higher temp or pressure = Higher altitude” ii. altimeters are usually adjustable for non-standard temperatures via a window in the instrument (i) 1” of pressure difference is equal to approximately 1000’ of altitude difference 2. components (1) static ports (2) pitot tube (3) pitot heat (4) alternate static ports (5) instruments - altimeter, airspeed, VSI gyroscopic system 1. overview (1) vacuum :system to allow high-speed air to spin certain gyroscopic instruments (2) typically vacuum engine-driven for some instruments, AND electrically driven for other instruments, to allow back-up in case of system failure (3) gyroscopic principles: i. rigidity in space - gyroscopes remains in a fixed position in the plane in which it is spinning ii.
    [Show full text]
  • Design and Development of a Wireless Pitot Tube for Utilization in Flight Test
    ABCM Symposium Series in Mechatronics - Vol. 5 Section VIII - Sensors & Actuators Copyright © 2012 by ABCM Page 1278 DESIGN AND DEVELOPMENT OF A WIRELESS PITOT TUBE FOR UTILIZATION IN FLIGHT TEST Igor Machado Malaquias, [email protected] Antonio Rafael da Silva Filho, [email protected] Paulo Henriques Iscold Andrade de Oliveira, [email protected] Universidade Federal de Minas Gerais – Departamento de Engenharia Mecânica – Av Antonio Carlos, 6627 – Pampulha – Belo Horizonte – Minas Gerais – Brasil, CEP 31.270-901 – (PPGMEC) Programa de Pós Graduação em Engenharia Mecânica Gonçalo Daniel Thums, [email protected] Universidade Federal de Minas Gerais – Departamento de Engenharia Elétrica – Av Antonio Carlos, 6627 – Pampulha – Belo Horizonte – Minas Gerais – Brasil CEP 31.270-901 Abstract. This paper presents the design and manufacture of a wireless Pitot tube for use in flight tests, it is also presented the mechanical design, electronic, calibration and validation trial of such equipment. The Pitot tube in question was designed to operate together with the data acquisition system developed at Centro de Estudos Aeronáuticos at Universidade Federal de Minas Gerais (CEA-FDAS – “Flight Data Aquisition System”). CEA-FDAS is a low cost data acquisition system for use in flight tests, which can be coupled to several sensors / devices. One of these devices, as in conventional flight test system consists of a Pitot tube with four sensors, which in most cases must be installed on the wingtip of the aircraft, with the acquisition of static and dynamic pressure, and even a set of two flags to determine the angles of attack and sideslip. The fact that the Pitot tube in question has no wires to connect with the data acquisition system is its best advantage when compared to its peers, what makes the installation process very simple and fast in addition it is compatible with any type of aircraft by simply providing the attachment means to this structure.
    [Show full text]
  • 1. Introduction to Pitot Tube Flow Measurement
    1. Introduction to Pitot Tube Flow Measurement Pressure sensors are classified as Differential Pressure sensors for flow measurement. The measuring principle of the pitot tube utilizes the differences between the pressure ridge on the upstream side of a bluff body and the static pressure on its down stream side. ITABAR-pitot tube sensors, see sample Fig 1.1, are mainly used to measure the volumetric flow of liquids, gases and steam in closed pipes ranging from ½“ to 480“ (DN 20 to DN 12000). Examples of their applications are precise volumetric flow measurement in batch processes, continuous measurement of liquid ingredients in the process industry, fuel, air, steam and gases as primary energy source as well as in control functions requiring a high degree of stability and repeatability. Examplary in comparsion to almost all other flow measuring instruments is the ITABAR-sensor’s ease of installation. The installation consists of these steps: drilling of the pipe, weld-o- let is welded on to the pipe, ITABAR is inserted. Models Flo- Tap FT , see Fig 1.2, allows installation and removal without Fig 1.1 shutting the process down. ITABAR-pitot tube sensors were developed with the goal of high reliability even under difficult conditions. ITABAR-pitot tube sensors are optimized in several ways with respect to fluid stream conditions. Advantages of the engineered sensor profile are their low permanent pressure loss as well as the constistent measurement accuracy over a wide range of Reynolds numbers. For over two decades ITABAR-pitot tube sensors have been applied in the industrial world. Their examplary reliability and excellent long-term use record resulted in broad acceptance by customers.
    [Show full text]
  • GSW-8 Flight Instruments
    GSW-8 Flight Instruments READING ASSIGNMENT PHAK Chapter 8 – Flight Instruments Study Questions 1. In addition to being able to read and interpret flight instruments, a pilot must also be able to a) build replacement flight instruments from spare parts. b) detect changes in altitude, airspeed, and heading using only body signals. c) recognize errors and malfunctions of these instruments during preflight inspection and in the air. Pitot-Static System 2. Impact air pressure is taken from the ___________________________________ , and ___________________________________ air pressure is usually taken from vents mounted flush with the fuselage. 3. A change in airspeed will affect the air pressure in which line of the pitot-static system? a) Static air pressure in the static line. b) Impact air pressure in the pitot line. c) Air pressure in both lines will change. 4. A change in altitude will affect the air pressure in which line of the pitot-static system? a) Static air pressure in the static line. b) Impact air pressure in the pitot line. GSW-8 c) Air pressure in both lines will change. 5. During preflight inspection, if a pilot notices a blocked or partially blocked static vent, how should it be ? resolved? a) The pilot should blow forcefully on the vent hole until the clog dislodges. b) A certificated mechanic should be notified so that he or she can remove the blockage. c) The clog will likely remove itself during slipping flight. 6. Which flight instrument uses impact pressure from the pitot line? ___________________________________________________________________________________ 7. Why do many planes have more than one static port? a) Multiple ports allow air pressure to equalize from one side of the airplane to the other.
    [Show full text]
  • Fluids Lab 1 – Lecture Notes
    Fluids Lab 1 – Lecture Notes 1. Bernoulli Equation 2. Pitot-Static Tube 3. Airspeed Measurement 4. Pressure Nondimensionalization References: Anderson 3.2-3.5, Denker 3.4 ( http://www.av8n.com/how/ ) Bernoulli Equation Definition For every point s along a streamline in frictionless flow with constant density ρ, the local speed V (s)= |V~ | and local pressure p(s) are related by the Bernoulli Equation 1 p + ρV 2 = p (1) 2 o This po is a constant for all points along the streamline, even though p and V may vary. This is illustrated in the plot of p(s) and po(s) along a streamline near a wing, for instance. 1ρ 2 2 V po p s s Standard terminology is as follows. p = static pressure 1 ρV 2 = dynamic pressure 2 po = stagnation pressure, or total pressure Also, a commonly-used shorthand for the dynamic pressure is 1 2 q ≡ ρV 2 so we can also write the Bernoulli equation in the following compact form. p + q = po 1 Uniform Upstream Flow Case Many practical flow situations have uniform flow somewhere upstream, with V~ (x, y, z)= V~∞ and p(x, y, z) = p∞ at every upstream point. This uniform flow can be either at rest with V~∞ ≃ 0 (as in a reservoir), or be moving with uniform velocity V~∞ =6 0 (as in a upstream wind tunnel section), as shown in the figure. V(x,y,z) V(x,y,z) p(x,y,z) p(x,y,z) V = 0 V = const. p = const. p = const.
    [Show full text]
  • Lo 022 Instrumentation
    022 INSTRUMENTATION AIRLINE TRANSPORT PILOTS LICENCE (A) (AIRCRAFT GENERAL KNOWLEDGE) JAR-FCL LEARNING OBJECTIVES REMARKS REF NO 022 00 00 00 INSTRUMENTATION 022 01 00 00 FLIGHT INSTRUMENTS 022 01 01 00 Air Data Instruments 022 01 01 01 Pilot and Static Systems – State the purpose of the pitot and static system. – Indicate the information provided by the pitot and static system. – Name the components of the pitot and static pressure system. – Pitot tube, construction and principles of operation – Name and state the purpose of each element of the pitot tube. – Explain the principles of operation of the pitot tube. – Illustrate the distribution of the pitot pressure to instruments and systems. – Indicate various locations of the pitot tube in relation to the direction of air flow. – Name the existing pitot tube designs. – Static source – Explain the principle of operation of the static port. – Illustrate the distribution of the static pressure to instruments and systems. – Indicate various locations of the static port. – Define the static pressure error – Describe the purpose of static balancing – Malfunction – State, in qualitative terms, the effects on the indications of altimeter, airspeed indicator and Issue 1: Oct 1999 022-INST-2 CJAA Licensing Division AIRLINE TRANSPORT PILOTS LICENCE (A) (AIRCRAFT GENERAL KNOWLEDGE) JAR-FCL LEARNING OBJECTIVES REMARKS REF NO variometer (vertical speed indicator) in the event of a blockage or a break of: – Total pressure line – Static pressure line – Total and static pressure line – Heating – Explain the purpose of heating. – Interpret the effect of heating on sensed pressure. – Alternate static source – Explain why an alternate static source is required.
    [Show full text]
  • Flight Environmental Systems
    CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR22 FLIGHT ENVIRONMENTAL SYSTEMS 1. DESCRIPTION This section covers that portion of the system which senses environmental conditions and uses the data to influence navigation of the airplane. This includes pitot-static, Vertical Speed Indicator (VSI), altimeter, air- speed indicator, and Outside Air Temperature (OAT) gage/clock. (See Figure 34-001) The pitot system utilizes an “L” shaped mast with integral pitot tube and heater located on the LH wing just inboard of the wing tip to sense impact or ram air pressure. The pitot mast utilizes an electrical heating ele- ment to prevent ice from blocking ram air. Pitot heat is controlled by a switch located in the center of the bolster switch panel. An amber PITOT HEAT light on the annunciation panel will illuminate if the PITOT HEAT switch is set to ON position and the pitot heater is not using power. The pitot heat system operates on 28 VDC supplied through the 7.5-amp PITOT HEAT/COOLING FAN cir- cuit breaker on the Non-Essential Bus. The PITOT HEAT warning light operates on 28 VDC supplied through the 2-amp ANNUN circuit breaker on the Essential Bus. The normal static system utilizes two ports, a static source water trap, an alternate static source selector valve, and the necessary plumbing to provide static air pressure sensing for the airspeed indicator, vertical speed indicator, altimeter, altitude encoder, and altitude transducer. Serials 0435 thru 0820 w/ PFD, 0821 & subs: The primary flight display (PFD) receives static air pressure data through the static system. The normal static ports are located on the LH and RH sides of the fuselage behind the aft cabin bulkhead.
    [Show full text]