REXUS Manhole Covers

Total Page:16

File Type:pdf, Size:1020Kb

REXUS Manhole Covers CertainTeed REXUS Manhole Covers PAM products have achieved a worldwide leadership PAM Access Covers, Curb Units and Gratings. position by delivering on CertainTeed’s core values CertainTeed has an extensive network of agents and distributors, which of safety, quality and compliance with national and ensures that products and technical advice are always available locally. Access Covers and Gratings international standards. The REXUS manhole cover For more information call 1-877-351-3323, or refer to the PAM general draws on many years of experience in the design presentation brochure or specific product brochures shown below. and manufacture of safe, durable and efficient municipal castings. REXUS Manhole Covers Designed for the intense traffic conditions found in North America, the H20 load rated REXUS cover is a one-man Additional literature: operable unit that meets the needs of public utility engineering and maintenance personnel in the areas of performance, operation and safety. Highlights There are over 6 million PAM units in the ground around the world utilizing technically advanced materials and • Ductile iron • Cover with 90° engineering. Our focus on the needs of the end-user — blocking mechanism rather than developing products merely to meet a • Spring bar locking minimum performance standard — led us to ductile • Exceeds H20 loading iron, a superior alternative to cast iron in terms of • Available in 24" opening • Optional locking features weight, strength and designability. • Hinged cover • Independently certified PAM General Brochure PAMREX Manhole Covers PAMTIGHT Manhole Covers Chamber for locking kits Key hole Product information and traceability: - H20 loading - EN 124 Frame embedment slots REXUS Gratings SELECTA Curb Units - Date of manufacture Loops ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS: Spline location Hinge ROOFING • SIDING • WINDOWS • INSULATION • FENCE • RAILING • DECK • FOUNDATIONS • PIPE • ACCESS COVERS CertainTeed Corporation Telephone: 877-351-3323 P.O. Box 860 Fax: 877-351-3320 Valley Forge, PA 19482 www.certainteed-pamcovers.com © 8/06 CertainTeed Corporation, Printed in U.S.A. CTPAM-0002R-5M-SGCS-SO Advanced Ergonomics Quality Assurance Spring Bar Lock – The key can only be released once • Requires use of the SCS Kits for REXUS Covers the manhole cover is locked, thus SCS key included REXUS features a unique spring bar locking system, MODEL REFERENCES REXUS enables utility personnel to undertake The REXUS cover has been designed and manufactured making it impossible to forget to in the complete kit which is an integral part of the unit. This locking sys- Kit with handling key C15 lock the cover. or sold separately. visual inspections and routine maintenance of within a certified ISO 9000 quality management sys- tem combines ductile iron technology and decades of Kit without handling key C16 – It is recommended the underground networks with the minimum effort tem, certified by an independently and internationally extensive experience in designing and manufacturing • On-site installation takes five minutes: Handling key C18 SCS key not be used and in complete safety. recognized third party. REXUS has been subjected to a ductile iron municipal castings. – Punch out the center of the locking strict testing program. to open the covers. Covers should only be opened • Hinge design reduces the bolt area. How does the spring bar lock function? using standard tools and the lifting points provided. effort of opening covers • Laboratory testing: accelerated wear test. site adjustment. Any unauthorized modification of the – Install the kit in compliance by 50% utilizing standard By harnessing the compressive forces that are created with the instructions supplied. • Extensive field testing, including high speeds and spring bar may adversely affect its performance. tools (pickaxe and hooks). when the spring bar is in the closed position, the cover heavy traffic conditions. These tests confirmed that is held securely against the seating ring. Horizontal Durability of the seating ring • Hinge reduces the duration REXUS can be used in any major thoroughfare. and vertical movement of the cover is thus eliminated, of the lift, thereby reducing so that the cover is silent in operation. The spring bar The seating ring is manufactured from a specifically the risk of injury to the automatically activates when the cover is closed. formulated composite material that is known to operator. Advanced Safety have a high resistance to extremes of temperature, abrasion and shocks resulting from traffic flow and The REXUS Cover Range Ductile iron technology enables the development of cover operation. super-strong, ultralight covers and frames. • Hinge retains the cover in a safe and controlled Frame REXUS, CIRCULAR FRAME AND COVER, NON-VENTILATED, FITTED WITH ANTI-THEFT SPLINE Seating manner throughout the opening and closing • The spring bar locking mechanism ensures the ring BADGINGS REFERENCES MASS (LBS.) DIMENSIONS (IN.) sequence. cover and frame seating remain in perfect contact. REXUS Anti-theft Cover Locks COVER TOTAL A O H Spring bar integral with cover Standard (none) CDRU60EH 91 155 33-1/4 24 4 • Lifting loops incorporated into the frame ease • The locking mechanism keeps the cover held Penta Locking Kit Sewer CDRU60EHSEW 91 155 33-1/4 24 4 handling and installation with appropriate and against the sound-proofing ring; the cover is pre- • 1/4 turn lock actuated by an asymmetrical safe equipment. vented from rocking and complete silence How is the spring bar lock released? Sanitary sewer CDRU60EHSSE 91 155 33-1/4 24 4 five-sided bolt head. is ensured. • Opening — The spring bar lock Drain CDRU60EHDRA 91 155 33-1/4 24 4 Strength • The cover can be locked without any special tools, is deactivated by inserting a • On-site installation takes five minutes: simply by applying pressure with the foot. bar/pickaxe blade into the – Punch out the center of the locking bolt area. prizing slot in the front – Install the kit in compliance with the instruc- • REXUS significantly exceeds the AASHTO • Before reopening the road to traffic, utility personnel of the frame, then apply- tions supplied. (American Association of State Highway and must make sure that the cover is properly replaced ing a little Transportation Officials) H20 heavy duty load • Lock must be operated with the and that the spring bar lock has engaged. upward force until resistance requirement. handling key (supplied with the the cover pops open. kit; can be purchased separately). • REXUS is independently tested by an accredited Security • Closing — The organization to ≥ 100,000 lbs. spring bar lock Penta Kits for REXUS Covers REXUS offers four improved levels will be auto- MODEL REFERENCES of security, designed to provide matically acti- Kit with handling key C13 increasing degrees of resist- vated if the Kit without handling key C14 ance to unauthorized access. cover is released Handling key C17 It must be noted that none part way through its of these levels will prevent closing arc. If the cover has been gently lowered the determined criminal or into position it may be necessary to step on the Specification raised part of the cover to ensure the spring bar vandal from gaining access. • REXUS or similar approved Manhole Cover • Additional security features shall include a device to lock has deployed correctly. and Frame. prevent the Cover from being completely removed • Prevention of cover theft from the Frame. This device shall be capable of being is achieved by activating • Covers and Frames shall be manufactured from Durability of the spring bar lock SCS Locking Kit Ductile Iron in accordance with ISO 1083. deactivated if required. a spline located in the hinge housing. The safety The spring bar lock has been designed to operate with- • 1/4 turn lock is activated by a bolt that has a • Frames shall be circular and shall incorporate a blocking is activated once the cover is in the frame. • Covers shall be hinged and incorporate a 90° in the elastic limit of the specific grade of the ductile unique notched cylindrical head design. This blocking system to prevent accidental closure. seating ring, and shall have a 24" clear opening. • Resistance to young children comes as standard iron we produce in our foundry. In the laboratory, feature improves security by ensuring that the • Covers shall be one-man operable using standard • Frame depth shall not exceed 4"; frame flanges thanks to the spring bar lock, which requires a tool more than 400 opening and closing cycles were per- SCS locking key can only be removed once tools and shall be capable of withstanding a shall incorporate bedding slots and bolt holes. and physical strength to deactivate. formed, during which the spring bar lock retained its the manhole cover has been returned to the minimum load of 100,000 lbs. • All components shall be black coated. efficiency. As far as field testing, this technology is now • Product shall be manufactured in ISO 9000 certified • Unauthorized access is prevented by fitting the locked position. • Covers shall incorporate a spring bar locking system, seven years old, with more than 1 million units in which automatically activates when the Cover is closed. manufacturing plants. Penta locking kit. service. The spring bar lock does not require any on- • The SCS key has an internal trigger-operated lug • Additional security can be provided by the SCS that releases the key from the head of the bolt. locking kit. Advanced Ergonomics Quality Assurance Spring Bar Lock – The key can only be released once • Requires use of the SCS Kits for REXUS Covers the manhole cover is locked, thus SCS key included REXUS features a unique spring bar locking system, MODEL REFERENCES REXUS enables utility personnel to undertake The REXUS cover has been designed and manufactured making it impossible to forget to in the complete kit which is an integral part of the unit. This locking sys- Kit with handling key C15 lock the cover.
Recommended publications
  • Section 02560 Manholes Part 1
    SECTION 02560 MANHOLES PART 1 - GENERAL 1.01 SCOPE The work covered by this Section includes furnishing all labor, equipment and materials required to install cast-in-place, and/or precast concrete manholes, and concrete junction chambers as described herein and/or shown on the Drawings. 1.02 DESIGN CRITERIA A. Manholes shall be constructed of specified materials to the sizes, shapes, and dimensions and at the locations shown on the Drawings or as otherwise directed by the ENGINEER. The height or depth of the manhole will vary with the location, but unless shown otherwise on the Drawings shall be such that the top of the manhole frame will be at the finished grade of the pavement or ground surface and the invert will be at the designed elevations. B. Where the difference in the invert elevation of a sewer 18 inches in diameter or smaller and any other sewer intersecting in one manhole is 18 inches or more, a dropmanhole shall be constructed as shown on the Drawings. They shall be similar in construction to the standard manhole except that a drop connection of pipe and fittings of the proper size and material shall be constructed outside the manhole and be supported by Class B Concrete. 1.03 QUALITY ASSURANCE A. Prior to delivery all basic materials specified herein shall be tested and inspected by an approved independent commercial testing laboratory or, if approved by the ENGINEER, certified copies of test reports prepared by the manufacturer's testing laboratory will be acceptable. All materials which fail to conform to these specifications shall be rejected.
    [Show full text]
  • SDD 8B10 Manholes 3X3-FT, 4X4-FT, 5X5-FT, and 6X6-FT
    SDD 8b10 Manholes 3x3-FT, 4x4-FT, 5x5-FT, and 6x6-FT PRECAST OR CAST-IN-PLACE GENERAL NOTES REINFORCED CONCRETE FLAT SLAB TOP DETAILS OF CONSTRUCTION, MATERIALS AND WORKMANSHIP NOT SHOWN ON THIS DRAWING SHALL CONFORM TO THE PERTINENT REQUIREMENTS OF THE STANDARD SPECIFICATIONS AND THE APPLICABLE SPECIAL PROVISIONS. UNLESS OTHERWISE AUTHORIZED IN WRITING BY THE ENGINEER, THE CONTRACTOR SHALL NOT ORDER AND DELIVER PRECAST MANHOLE UNITS REQUIRED FOR THE PROJECT UNTIL A LIST OF SIZES IS FURNISHED BY THE ENGINEER. 2" (TYP) B B DETAILED DRAWINGS FOR PROPOSED ALTERNATE DESIGNS FOR UNDERGROUND DRAINAGE STRUCTURES SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PROVIDING THAT SUCH ALTERNATE DESIGNS MAKE PROVISION FOR EQUIVALENT CAPACITY AND STRENGTH. SEE MATRIX ALL DRAINAGE STRUCTURES ARE DESIGNATED ON THE PLANS AS "MANHOLES 3X3-L", "CATCH BASINS 4-B", TOP WITH PLAIN END JOINT "INLETS 2X3-H", ETC. THE FIRST NUMBERS DESIGNATE THE SIZE OF THE STRUCTURE, AND THE FOLLOWING LETTER DESIGNATES THE TYPE OF COVER TO BE USED TO COMPRISE THE COMPLETE UNIT. BASES SHALL BE PLACED ON A BED OF MATERIAL AT LEAST 6 INCHES IN DEPTH, WHICH MEETS THE REQUIREMENTS OF FOUNDATION BACKFILL. THIS BEDDING SHALL BE COMPACTED AND PROVIDE UNIFORM " 8 SUPPORT FOR THE ENTIRE AREA OF THE BASE. 4" OVERHANGING BASE PRECAST REINFORCED FLAT SLAB TOPS MAY BE USED ON CONCRETE BLOCK STRUCTURES. 1 OR 2 2 STEPS MEETING AASHTO M199 AND THE FOLLOWING REQUIREMENTS SHALL BE INSTALLED IN ALL STRUCTURES OVER 5 FEET IN DEPTH: 16 INCH C-C MAXIMUM SPACING; PROJECT A MINIMUM CLEAR DISTANCE OF 4 INCHES FROM PLAN VIEW THE WALL AT THE POINT OF EMBEDMENT; MINIMUM LENGTH OF 10 INCHES; MINIMUM WALL EMBEDMENT OF 3 CIRCULAR OPENING SECTION A-A INCHES.
    [Show full text]
  • D400tc – Composite Manhole Cover Class D400 – En 124:1994
    Rev. 00 D400TC – COMPOSITE MANHOLE COVER CLASS D400 – EN 124:1994 DESCRIPTION PROPERTIES Manhole covers and gully tops Marked with resistance class, for use in vehicular and reference norm, producer pedestrian areas. Design identification and quality requirements, type testing, mark released by an marking, quality control internationally according to the UNI EN acknowledged certification 124:1994 standard. authority. Certificate issued by ICMQ. Made up of: - round frame - round cover - locking system with 180° or 120° hinge Name of the client or of the optional service. Embossed pattern available on request. PRODUCTION PROCESS Illustrations and drawings APPLICATION AREAS AND MATERIAL are purely illustrative Test load kN 400. The manhole cover is Carriageways (including manufactured through the pedestrian streets), SMC process, i.e. compression hardshoulders and parking moulding in a closed mould, areas for all types of road using a Sheet Moulding vehicles. Compound (polyester reinforced with glass fibres). Raw materials: orthophtalic polyester resin, chopped strand in glass fibres (type E), additives. Hinges and closing systems are made of galvanized steel. Weight of the D F H h cover + weight MODEL C/O Fixing Seal (mm) (mm) (mm) (mm) of the frame (Kg) 180° hinge and D400TC/600_001 600 690 805 100 50 Yes 36 + 17 lock 120° hinge and D400TC/600_002 600 650 790 100 48 Yes 31,6 + 13,4 lock 180° hinge and D400TC/700_001 700 750 910 100 50 Yes 45,5 + 20,5 lock Rev. 00 D400T - COMPOSITE MANHOLE COVER CLASS D400 – EN 124:1994 DESCRIPTION PROPERTIES Manhole covers and gully tops Marked with resistance class, for use in vehicular and reference norm, producer pedestrian areas.
    [Show full text]
  • Version 09-10-2019
    Version 09-10-2019 Version 09-10-19 Table of Contents SECTION 1- GENERAL REQUIREMENT ............................................................................................ 1 1.01 Short Title .................................................................................................................................... 2 1.02 Interpretation ............................................................................................................................... 2 1.03 Enforcement ................................................................................................................................ 2 1.04 Amendment ................................................................................................................................. 2 1.05 Deviation Requests ...................................................................................................................... 2 1.06 Applicability ................................................................................................................................ 3 1.07 Other Local, State and Federal Environmental Regulations .......................................................... 3 1.08 Texas Accessibility Standards (TAS) ........................................................................................... 3 1.09 Engineering Criteria – Section Descriptions ................................................................................. 4 1.10 Submittal Requirements for Construction Plans ...........................................................................
    [Show full text]
  • Safety of the Intended Functionality of Lane-Centering and Lane-Changing Maneuvers of a Generic Level 3 Highway Chauffeur System (Report No
    DOT HS 812 879 November 2020 Safety of the Intended Functionality of Lane- Centering and Lane- Changing Maneuvers of a Generic Level 3 Highway Chauffeur System DISCLAIMER This publication is distributed by the U.S. Department of Transportation, National Highway Traffic Safety Administration, in the interest of information exchange. The opinions, findings, and conclusions expressed in this publication are those of the authors and not necessarily those of the Department of Transportation or the National Highway Traffic Safety Administration. The United States Government assumes no liability for its contents or use thereof. If trade or manufacturers’ names or products are mentioned, it is because they are considered essential to the object of the publications and should not be construed as an endorsement. The United States Government does not endorse products or manufacturers. Suggested APA Format Citation: Becker, C. J., Brewer, J. C., & Yount, L. J. (2020, November). Safety of the intended functionality of lane-centering and lane-changing maneuvers of a generic level 3 highway chauffeur system (Report No. DOT HS 812 879). National Highway Traffic Safety Administration. Technical Report Documentation Page 1. Report No. 2. Government Accession No. 3. Recipient’s Catalog No. DOT HS 812 879 4. Title and Subtitle 5. Report Date Safety of the Intended Functionality of Lane-Centering and Lane-Changing November 2020 Maneuvers of a Generic Level 3 Highway Chauffeur System 6. Performing Organization Code 7. Authors 8. Performing Organization Report No. Christopher Becker, John Brewer, and Larry Yount DOT-VNTSC-NHTSA-19-02 9. Performing Organization Name and Address 10. Work Unit No.
    [Show full text]
  • Standard Construction Specifications for Storm Drain Systems Division 55 Index
    STANDARD CONSTRUCTION SPECIFICATIONS FOR STORM DRAIN SYSTEMS DIVISION 55 INDEX SECTION 55.01 GENERAL....................................................................................... 1 Article 1.1 Scope of Work................................................................................. 1 Article 1.2 Applicable Standards ...................................................................... 1 Article 1.3 Surveys ........................................................................................... 2 Article 1.4 Concrete and Mortar ....................................................................... 2 Article 1.5 Payment - General.......................................................................... 3 SECTION 55.02 FURNISH AND INSTALL PIPE....................................................... 4 Article 2.1 General ........................................................................................... 4 Article 2.2 Material ........................................................................................... 4 Article 2.3 Construction.................................................................................... 8 Article 2.4 Measurement ................................................................................ 13 Article 2.5 Basis of Payment .......................................................................... 13 SECTION 55.03 SUBDRAINS ................................................................................. 14 Article 3.1 General ........................................................................................
    [Show full text]
  • MANHOLE CASTING REFERENCE GUIDE TABLE of CONTENTS Materials………...……
    MANHOLE CASTING REFERENCE GUIDE TABLE OF CONTENTS Materials………...…….. ................................................ 2 Load Bearing.... ............................................................. 3 Key Dimensions of Round Frame and Cover ................ 3 Key Dimensions of Inlet Frame and Grate .................... 4 Frame Designs .............................................................. 5 Grate Designs ............................................................... 6 Curb Inlets or Combination Inlets ................................. 7 Watertight Frames and Covers ..................................... 8 Materials Airport Castings ............................................................. 8 QUICK REFERENCE Manhole Features .....................................................9-10 All the iron provided in a product should have a minimum recycled material content of 85%. All manufacturers should provide material certifications on product that includes country of origin and material quality and if requested, shall NATIONAL PRECAST CONCRETE ASSOCIATION provide load test data on the casting. With nearly 1,000 member companies, NPCA serves as the voice of the precast concrete industry in the United Gray Iron States and Canada. The industry includes a diverse mix Iron conforming to ASTM A48, Class 35B, as noted in of companies, from small single-plant manufacturers section 7.1.1 and 7.1.3 of AASHTO M306. Class 35B exhibits to multinational vertically integrated companies the best corrosion and wear resistance properties as well that
    [Show full text]
  • Standard Plans
    STANDARD PLANS CITY OF HUNTINGTON BEACH DEPARTMENT OF PUBLIC WORKS Series 100 and 200 –General Notes and Street Improvement Standards # Page Description Revision Date 100 1 of 4 General Notes 5/1/2008 100 2 of 4 General Notes 5/1/2008 100 3 of 4 General Notes 5/1/2008 100 4 of 4 General Notes 5/1/2008 101 Major Arterial Highway Typical Section 5/1/2008 102 Primary Arterial Highway Typical Section 5/1/2008 103 Secondary Arterial Highway Typical Section 5/1/2008 104 Local Streets Typical Section 5/1/2008 105 Knuckle Details 3/21/1994 106 Cul-de-sac 3/21/1994 107 1 of 3 Alley Approach 5/1/2008 107 2 of 3 Alley Section 5/1/2008 107 3 of 3 Alley Section 5/1/2008 108 Landscape Med. Moisture Barrier Detail 5/1/2008 109 Trench / Pavement Repair Detail 5/1/2008 110 Steel Plate Bridging 5/1/2008 111 Material Storage in R/W 5/1/2008 201 Curb Section 5/1/2008 202 Curb & Gutter Section 5/1/2008 203 1 of 2 Corner Bus Turnout 5/1/2008 203 2 of 2 Mid-Block Bus Turnout 5/1/2008 204 Residential Lot Drain 5/1/2008 205 Concrete Cross Gutter 5/1/2008 206 16' Concrete Cross Gutter 5/1/2008 207 Sidewalk and Parkway 5/1/2008 209 Residential Driveway Approach 5/1/2008 211 1 of 2 Commercial and Industrial Drive Approach 5/1/2008 211 2 of 2 Commercial and Industrial Drive Approach 5/1/2008 215 1 of 3 Utility conduit locations in r/w 5/1/2008 215 2 of 3 Utility conduit locations in r/w 5/1/2008 215 3 of 3 Utility conduit locations in r/w 5/1/2008 216 Private Street Rolled Curb 5/1/2008 217 Parkway Repair for Utility Box Installation 5/1/2008 218 3' Longitudinal
    [Show full text]
  • Plan Preparation Guide Chapter 9 Section Description Page 1 Plans
    Plan Preparation Guide Chapter 9 Drainage Structures – R.C. Box Culverts – Ditches - Gutters - Curbs Section Description Page 1 Plans for Hydrology 9-1 2 Catch Basin Types and Uses 9-2 3 Drop Inlet Types and Uses 9-5 4 Pipe End Structures and Uses 9-6 5 Catch Basin Spacing for Types 16,17, 9-7 and 18 6 Catch Basin Spacing for Type 15 9-25 7 Precast Drainage Structures 9-28 8 Pipe Requirements 9-30 9 Concrete Pipe Data 9-32 10 Beveled End Pipe 9-33 11 Pipe Tee Joints, WYE Joints, and 9-35 Bends 12 Criteria for Placing Paved Gutter 9-37 13 Culvert Sketches 9-37 14 Curb Profile 9-37 15 Green Areas 9-37 16 Trench Drain Applications 9-38 1. Plans For Hydrology Submit to Hydrology all plans (including ‘C’) that have ditches with slopes greater than 3%. Printouts of existing drainage elevations, outfall ditches and any other pertinent information will be supplied by SCDOT Road Design Section as needed. The “view only” access will be provided by the Hydraulic Engineering Office in order to share files over the network. Design Groups will copy necessary files to the ftp server for on-call consultants. Consultants should add new pipe, drainage structures, outfall ditches, and notes to plan sheets in red and new NPDES items and text in green. Department personnel will place those new additions onto the original plans upon return to Road Design. Drainage design and NPDES can be shown on the same plan sheet. If sheets become cluttered, this can be reviewed on a per case basis.
    [Show full text]
  • Technical Specification
    TECHNICAL SPECIFICATION ITEM 00470 BRICK MANHOLES 470.1 Description. This item shall govern for the construction of brick manholes on sanitary sewer lines or storm sewers, 72-inch in diameter or smaller including the materials used therein and the furnishing of frame, rings and covers. Manholes for pipe sized greater than 72-inch, use precast concrete manholes. 470.2 Materials. Reinforcing steel shall conform to the Item, "Reinforcing Steel". Concrete shall conform to the Item, "Structural Concrete". Mortar shall conform to ASTM C270, Type M, using Portland Cement. Aggregate for Mortar shall conform to ASTM C144. Cast iron shall conform to ASTM A48, Class No. 30 - Cast iron manhole frames and covers shall be manufactured to the dimensions shown on the attached drawing. Casting shall be free from sand or blow holes and other defects. Holes in cover to be free from plugs and burrs. The machined bearing surfaces of manhole frames and covers shall obtain even bearing. Cast wording "Sanitary Sewer" or "Storm Sewer", as applicable. Thirty-two (32) inch manhole covers will be used on all manholes. Concrete brick shall be in accordance with ASTM C55, Grade A. Concrete brick is not allowed for the construction of sanitary sewer manholes. Bricks shall be of first quality, sound, hard-burned perfectly shaped brick. Shale bricks, if used, shall be homogeneous thoroughly and uniformly burned. Bricks shall not absorb more than 16- percent of water by weight when submerged in water for 24-hours, having been in a completely dry state prior to placing in water. Clay brick shall conform to the requirements of ASTM Designation C32, Grade NA, except that not more than 16% maximum individual brick absorption will be permitted.
    [Show full text]
  • Manhole Cover Finishes Detail - in Road Proj Origin Zone Level Type Role Number 232207-70 232207-70-AR-01-XX-DR-C-00200
    Mortar bedding and haunching 600 mm x 600 mm clear opening 600 mm x 600 mm clear opening to cover and frame Plastic chambers and rings shall comply with BS EN 13598-1 and NOTES:- cover complying with cover complying with to Clause E6.7 BS EN 124 and BS 7903 Mortar bedding and haunching BS EN 13598-2 or have equivalent independent approval BS EN 124 and BS 7903 1. Refer to drawing CD 002 for general notes. See Clause E2.32 to cover and frame Minimum 2 courses of Class B See Clause E2.32 Cover complying with to Clause E6.7 Sited in driveways/paved areas engineering bricks BS EN 124 and BS 7903 Minimum 2 courses of Class B 2. All dimensions in millimeters unless otherwise or precast concrete Mortar bedding and haunching to Driveways, footways and engineering bricks or precast noted. cover frame seating rings cover and frame to Clause E6.7 landscaped areas - Class B125 Minimum clear access 600 mm concrete cover frame seating rings 150 mm deep concrete collar See Clause E2.32 Minimum clear access 600 mm 3. This drawing to be read in conjunction with other Minimum radius to be 500 mm Minimum internal dimensions Precast concrete manhole for a 100 mm diameter pipe and 180 mm diameter or engineers and architects drawings. sections and cover slab to be 600 mm for a 150 mm diameter 225 mm x 100 mm bedded with mortar, plastomeric In-situ concrete to be GEN3 pipe to allow entry of DOT Type 1 sub base 4.
    [Show full text]
  • Precast Reinforced Concrete Manholes
    VALLECITOS WATER DISTRICT SECTION 03461 – PRECAST REINFORCED CONCRETE MANHOLES PART 1 – GENERAL 1.1 DESCRIPTION A. This section includes materials, testing, and installation of precast concrete manholes, manhole bases, manhole frames, and covers. 1.2 RELATED WORK SPECIFIED ELSEWHERE A. All related work specified elsewhere, or in other codes or standards, will be as last revised, unless a specific date of issuance is called out in opposition to later revision date(s). B. Other sections of the Standard Specifications, not referenced below, shall also apply to the extent required for proper performance of this Work. 1. Section 02223 - Trenching, Backfilling, and Compacting 2. Section 03300 – Concrete 3. Section 09801 - Manhole Protective Lining 4. Section 15042 - Leakage and Infiltration Testing 1.3 REFERENCE SPECIFICATIONS, CODES, AND STANDARDS A. The following standards have been referenced in this Section: 1. ASTM A48 Gray Iron Castings 2. ASTM A536 Ductile Iron Casting 3. ASTM C478 Precast Reinforced Concrete Manhole Sections 1.3 SUBMITTALS A. Submit manufacturer’s catalog and test data on precast concrete manholes, frames, and covers along with installation recommendations for inlet and outlet seals and watertight caulking. Show dimensions and materials of construction by ASTM reference and grade. Show manhole cover lettering and pattern. 1.4 PROJECT CONDITIONS A. Any proposed work inside an existing manhole that is part of a sewage system in service, shall not be undertaken until all the tests and safety provisions of Article 4, Section 1532 “Confined Spaces” State of California Construction Safety Orders have been made. PART 2 – PRODUCTS 2.1 PRECAST CONCRETE MANHOLES VWD NOVEMBER 2017 SECTION 03461 - 1 of 6 VALLECITOS WATER DISTRICT SECTION 03461 – PRECAST REINFORCED CONCRETE MANHOLES A.
    [Show full text]