Standard Manhole

Total Page:16

File Type:pdf, Size:1020Kb

Standard Manhole The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user. SLOPE SHELVES 1:12 TO DRAIN, TYP MANHOLE STEPS PIPE INVERTS AND SEE NOTE 3 MANHOLE ELEVATIONS PER PLANS CONFINED MASTIC MANHOLE FRAME O-RING AND COVER, SEE R= RADIUS OF STD DWG 516 MANHOLE, TYP SET FRAME IN NON-SHRINK CONFINED KEYLOCK GROUT O-RING JOINT JOINT PRECAST GRADE RINGS. 12" MAX 12" MAX SLOPE OF PRECAST 24" MAX ECCENTRIC CONE SHALL FACE DOWNSTREAM 12" TABLE (MINIMUM) PIPE MANHOLE WALL SIZE DIAMETER THICKNESS < 21" 48" 5" FINISH INTERIOR JOINTS 24"-27" 60" 6" WITH APPROVED NON-SHRINK GROUT, 30"-36" 72" 7" SEE NOTE 2 42"-48" 84" 8" LOCATE STEPS ALL OPENINGS SHALL BE ON UPSTREAM CORE DRILLED. PROVIDE SIDE OF MANHOLE, 12" MAX FLEXIBLE MANHOLE TO PIPE SEE STD DWG 522 CONNECTION, KOR-N-SEAL, OR APPROVED EQUAL, SEE NOTE 4 PRECAST MANHOLE BASE, 6" MIN THICKNESS STABLE SUBGRADE 6" MIN COMPACTED 3/4"-0" NOTES: GRANULAR BASE ROCK 1. CONCENTRIC CONES ARE NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY ENGINEER. ALL PRECAST SECTIONS SHALL MEET OR EXCEED ASTM C-478. 2. WATERTIGHT CONFINED O-RING OR MASTIC JOINTS REQUIRED. NON-SHRINK GROUT INSIDE JOINTS AND WALL PENETRATIONS SMOOTH FOLLOWING MANHOLE ASSEMBLY. 3. STEPS TO BE FACTORY INSTALLED POLYPROPYLENE PLASTIC WITH 1/2" GRADE 60 REINFORCEMENT. SEE STANDARD DRAWING 524. 4. ALL RIGID CONNECTING PIPES SHALL HAVE FLEXIBLE, GASKETED, UNRESTRAINED JOINT WITHIN 18". 2015 EDITION STANDARD DRAWING TITLE NO SCALE DEPARTMENT OF REVIEWED BY DIVISION PUBLIC WORKS JTA / LSL 09/15 SANITARY NAME DATE 362 N. THIRD AVENUE DRAWING NO. STAYTON, OR 97383 STANDARD MANHOLE PH: (503) 769-2919 REVISIONS FAX: (503) 767-2134 502 The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user. PIPE INVERTS AND MANHOLE ELEVATIONS PER PLANS SLOPE SHELVES 1:12 TO DRAIN, TYP MANHOLE STEPS, SEE NOTE 3 MANHOLE FRAME AND COVER, SEE STD DWG 516 R= RADIUS OF SET FRAME IN MANHOLE, TYP NON-SHRINK GROUT 12" MAX CONFINED O-RING PRECAST 24" MAX GRADE RINGS, 12" MAX MASTIC 12" SLOPE OF PRECAST ECCENTRIC CONE SHALL FACE DOWNSTREAM LOCATE STEPS CONFINED KEYLOCK ON UPSTREAM 48" MIN O-RING JOINT JOINT SIDE OF MANHOLE, SEE STD DWG 522 TABLE (MINIMUM) PIPE MANHOLE WALL FINISH INTERIOR JOINTS SIZE DIAMETER THICKNESS WITH APPROVED < 21" 48" 5" NON-SHRINK GROUT, 24"-27" 60" 6" SEE NOTE 2 30"-36" 72" 7" 42"-48" 84" 8" FLAT TOP SECTION, 8" MIN THICKNESS 6' MIN 12" ALL OPENINGS SHALL BE MAX CORE DRILLED. PROVIDE FLEXIBLE MANHOLE TO PIPE CONNECTION, KOR-N-SEAL, OR APPROVED EQUAL, SEE NOTE 4 STABLE PRECAST MANHOLE BASE, SUBGRADE 6" MIN THICKNESS NOTES: 6" MIN COMPACTED 3/4"-0" GRANULAR BASE ROCK 1. PRECAST SECTIONS SHALL MEET OR EXCEED ASTM C-478. 2. WATERTIGHT CONFINED O-RING OR MASTIC JOINTS REQUIRED. NON-SHRINK GROUT INSIDE JOINTS AND WALL PENETRATIONS SMOOTH FOLLOWING MANHOLE ASSEMBLY. 3. STEPS TO BE FACTORY INSTALLED POLYPROPYLENE PLASTIC WITH 1/2" GRADE 60 REINFORCMENT ROD. SEE STANDARD DRAWING 524. 4. ALL RIGID CONNECTING PIPES SHALL HAVE FLEXIBLE, GASKETED, UNRESTRAINED JOINT WITHIN 18". 2015 EDITION STANDARD DRAWING TITLE NO SCALE DEPARTMENT OF REVIEWED BY DIVISION PUBLIC WORKS JTA / LSL 09/15 STANDARD MANHOLE SANITARY NAME DATE 362 N. THIRD AVENUE DRAWING NO. STAYTON, OR 97383 FOR LARGE PH: (503) 769-2919 REVISIONS FAX: (503) 767-2134 DIAMETER PIPES 504 The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user. SLOPE SHELVES 1:12 TO DRAIN, TYP MANHOLE STEPS PIPE INVERTS AND SEE NOTE 4 MANHOLE ELEVATIONS PER PLANS CONFINED MASTIC O-RING R= RADIUS OF MANHOLE, TYP CONFINED KEYLOCK MANHOLE FRAME O-RING JOINT JOINT AND COVER, SEE STD DWG 516 TABLE (MINIMUM) PIPE MANHOLE WALL SET FRAME IN PRECAST SIZE DIAMETER THICKNESS NON-SHRINK GRADE < 21" 48" 5" GROUT RINGS, 24"-27" 60" 6" 12" MAX FLAT TOP SECTION, 12" MAX 8" MIN THICKNESS 24" MAX 12" 5" MIN FINISH INTERIOR JOINTS LOCATE STEPS WITH NON-SHRINK ON UPSTREAM GROUT, SEE NOTE 3 5' MAX SIDE OF MANHOLE, ALL OPENINGS SHALL BE SEE STD DWG 522 12" CORE DRILLED. PROVIDE MAX FLEXIBLE MANHOLE CONNECTION, KOR-N-SEAL, OR APPROVED EQUAL, SEE NOTE 5 STABLE PRECAST MANHOLE BASE, SUBGRADE 6" MIN THICKNESS 6" MIN COMPACTED 3/4"-0" NOTES: GRANULAR BASE ROCK 1. CONCENTRIC TOP SLABS ARE NOT PERMITTED UNLESS SPECIFICALLY APPROVED BY THE CITY ENGINEER. 2. PRECAST SECTIONS SHALL MEET OR EXCEED ASTM C-478. 3. WATERTIGHT O-RING OR MASTIC JOINTS REQUIRED. NON-SHRINK GROUT INSIDE JOINTS AND WALL PENETRATIONS SMOOTH FOLLOWING MANHOLE ASSEMBLY. 4. STEPS TO BE FACTORY INSTALLED POLYPROPYLENE PLASTIC WITH 1/2" GRADE 60 REINFORCMENT. SEE STANDARD DRAWING 524. 5. ALL RIGID CONNECTING PIPES SHALL HAVE FLEXIBLE, GASKETED, UNRESTRAINED JOINT WITHIN 18". 2015 EDITION STANDARD DRAWING TITLE NO SCALE DEPARTMENT OF REVIEWED BY DIVISION PUBLIC WORKS JTA / LSL 09/15 SANITARY NAME DATE STANDARD SHALLOW 362 N. THIRD AVENUE STAYTON, OR 97383 DRAWING NO. PH: (503) 769-2919 REVISIONS FAX: (503) 767-2134 FLAT TOP MANHOLE 506 The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user. VARIES 2" HIGH 2" HIGH MORTAR VARIES MORTAR KOR-N-SEAL OR DAM DAM APPROVED EQUAL KOR-N-SEAL OR AND GROUT, TYP APPROVED EQUAL AND GROUT, TYP WYE PIPE DIA TO MATCH MAIN PIPE DIA TO LINE PIPE MATCH MAIN DIAMETER, LINE PIPE 12" MAX DIAMETER, 12" MAX 45 BEND 90 BEND ON SANDBAG OR 90 BEND ON CONC SACK SANDBAG OR MIX SUPPORT CONC SACK MIX SUPPORT UNDISTURBED STABLE 6" MIN COMPACTED 3/4"-0" STABLE EARTH SUBGRADE GRANULAR BASE ROCK SUBGRADE 6" MIN COMPACTED 3/4"-0" TEE WYE GRANULAR BASE ROCK NOTES: 1. SEE STANDARD DRAWING 502, 504, AND 506 FOR ADDITIONAL REQUIREMENTS RELATIVE TO THE CONSTRUCTION OF PRECAST STANDARD AND FLAT-TOP MANHOLES. 2. DROP MANHOLES SHALL BE CONSTRUCTED WHERE THE DISTANCE BETWEEN PIPE INVERTS WILL EXCEED 24" IN SANITARY SEWER MANHOLES. PIPE INVERTS AND MANHOLE ELEVATIONS PER PLANS. 3. DROP ASSEMBLIES SHALL BE CONSTRUCTED OF PVC OR OTHER MATERIALS APPROVED FOR USE IN SANITARY SEWER SYSTEMS. 4. DROP ASSEMBLIES SHALL BE CONSTRUCTED ON THE OUTSIDE OF THE MANHOLE AS SHOWN. INSIDE DROP ASSEMBLIES ARE NOT PERMITTED WITHOUT THE APPROVAL OF THE CITY ENGINEER. 5. MAXIMUM SEWER MAIN SIZE SHALL BE 12-INCHES. 6. WYE DROP MAY BE REQUIRED OVER TEE DROP IN LOCATIONS OF HIGH FLOW OR STEEP GRADES. 2015 EDITION STANDARD DRAWING TITLE NO SCALE DEPARTMENT OF REVIEWED BY DIVISION PUBLIC WORKS JTA / LSL 09/15 STANDARD SANITARY NAME DATE 362 N. THIRD AVENUE DRAWING NO. STAYTON, OR 97383 OUTSIDE DROP PH: (503) 769-2919 REVISIONS FAX: (503) 767-2134 MANHOLE 508 The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user. 48" MIN FLEXIBLE MANHOLE TO PIPE CONNECTOR, KOR-N-SEAL, OR APPROVED EQUAL TEE REMOVABLE MECHANICAL PLUG DROP PIPE SHALL BE ASTM D3034 PVC INSTALLED FLUSH WITH INSIDE OF MANHOLE BARREL, FASTENED TO WALL WITH 1-1/2" x 10 GA. STAINLESS STEEL STRAPS AND 2 1/2" STAINLESS STEEL EXISTING BOLTS. STRAPS SHALL BE SPACED MANHOLE EVERY 4 FEET WITH A 2 STRAP MINIMUM. INSTALL 90 DEGREE BEND WITH 1-1/2" x 10 GA. STAINLESS STEEL STRAP, INSTALL CHANNEL TO DIRECT FLOW. ANCHOR SECURELY. NOTES: 1. THE USE OF INSIDE DROP MANHOLES WILL REQUIRE APPROVAL OF THE CITY ENGINEER. THE USE OF INSIDE DROP MANHOLES WILL BE LIMITED TO ONLY SINGLE-FAMILY AND MULTI-FAMILY RESIDENCES FOR CONNECTIONS TO EXISTING DEEP SANITARY SEWER SYSTEMS. NOT APPLICABLE TO COMMERCIAL OR INDUSTRIAL APPLICATIONS. 2. ONLY ONE INSIDE DROP CONNECTION ALLOWED PER MANHOLE. PIPE INVERT ELEVATIONS SHALL BE AS SHOWN ON THE PLANS. 3. MINIMUM MANHOLE DIAMETER WITH INSIDE DROP CONNECTION SHALL BE 48-INCHES. 4. MAXIMUM DROP PIPE DIAMETER SHALL BE 6-INCHES. 2015 EDITION STANDARD DRAWING TITLE NO SCALE DEPARTMENT OF REVIEWED BY DIVISION PUBLIC WORKS JTA / LSL 09/15 SANITARY NAME DATE STANDARD INSIDE 362 N. THIRD AVENUE STAYTON, OR 97383 DRAWING NO. PH: (503) 769-2919 REVISIONS FAX: (503) 767-2134 DROP MANHOLE 510 The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user. SLOPE SHELVES 1:12 TO DRAIN MANHOLE STEPS PIPE INVERTS AND MANHOLE ELEVATIONS PER PLANS PIPE SHALL BE SAWCUT CLEAN TO PROVIDE 24" WINDOW OPENING AS SHOWN MANHOLE FRAME AND COVER, SEE STD DWG 516 GRADE RINGS. 12" MAX 12" MAX SLOPE OF PRECAST 24" MAX ECCENTRIC CONE SHALL FACE DOWNSTREAM 12" STANDARD MANHOLE, SEE STD DWG 502 ALL OPENINGS SHALL BE CORE DRILLED. PROVIDE 24" WINDOW FLEXIBLE MANHOLE TO PIPE OPENING CONNECTION, KOR-N-SEAL, OR APPROVED EQUAL CONCRETE BENCH PIPE SHALL BE SAWCUT CLEAN TO SPRINGLINE TO PROVIDE 24" WINDOW OPENING FOR MONITORING AS SHOWN 6" MIN COMPACTED 3/4"-0" GRANULAR BASE ROCK STABLE SUBGRADE NOTES: 1. ALL MANHOLE SECTIONS SHALL CONFORM TO THE REQUIREMENT OF ASTM C478. SEE STANDARD DRAWING 502 FOR STANDARD MANHOLE DETAILS. 2015 EDITION STANDARD DRAWING TITLE NO SCALE DEPARTMENT OF REVIEWED BY DIVISION PUBLIC WORKS JTA / LSL 09/15 STANDARD SANITARY NAME DATE 362 N. THIRD AVENUE DRAWING NO. STAYTON, OR 97383 FLOW MONITORING PH: (503) 769-2919 REVISIONS FAX: (503) 767-2134 MANHOLE 512 The selection and use of this Standard Drawing, while designed in accordance with standard engineering principles and practices, is the sole responsibility of the user.
Recommended publications
  • Section 02560 Manholes Part 1
    SECTION 02560 MANHOLES PART 1 - GENERAL 1.01 SCOPE The work covered by this Section includes furnishing all labor, equipment and materials required to install cast-in-place, and/or precast concrete manholes, and concrete junction chambers as described herein and/or shown on the Drawings. 1.02 DESIGN CRITERIA A. Manholes shall be constructed of specified materials to the sizes, shapes, and dimensions and at the locations shown on the Drawings or as otherwise directed by the ENGINEER. The height or depth of the manhole will vary with the location, but unless shown otherwise on the Drawings shall be such that the top of the manhole frame will be at the finished grade of the pavement or ground surface and the invert will be at the designed elevations. B. Where the difference in the invert elevation of a sewer 18 inches in diameter or smaller and any other sewer intersecting in one manhole is 18 inches or more, a dropmanhole shall be constructed as shown on the Drawings. They shall be similar in construction to the standard manhole except that a drop connection of pipe and fittings of the proper size and material shall be constructed outside the manhole and be supported by Class B Concrete. 1.03 QUALITY ASSURANCE A. Prior to delivery all basic materials specified herein shall be tested and inspected by an approved independent commercial testing laboratory or, if approved by the ENGINEER, certified copies of test reports prepared by the manufacturer's testing laboratory will be acceptable. All materials which fail to conform to these specifications shall be rejected.
    [Show full text]
  • SDD 8B10 Manholes 3X3-FT, 4X4-FT, 5X5-FT, and 6X6-FT
    SDD 8b10 Manholes 3x3-FT, 4x4-FT, 5x5-FT, and 6x6-FT PRECAST OR CAST-IN-PLACE GENERAL NOTES REINFORCED CONCRETE FLAT SLAB TOP DETAILS OF CONSTRUCTION, MATERIALS AND WORKMANSHIP NOT SHOWN ON THIS DRAWING SHALL CONFORM TO THE PERTINENT REQUIREMENTS OF THE STANDARD SPECIFICATIONS AND THE APPLICABLE SPECIAL PROVISIONS. UNLESS OTHERWISE AUTHORIZED IN WRITING BY THE ENGINEER, THE CONTRACTOR SHALL NOT ORDER AND DELIVER PRECAST MANHOLE UNITS REQUIRED FOR THE PROJECT UNTIL A LIST OF SIZES IS FURNISHED BY THE ENGINEER. 2" (TYP) B B DETAILED DRAWINGS FOR PROPOSED ALTERNATE DESIGNS FOR UNDERGROUND DRAINAGE STRUCTURES SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PROVIDING THAT SUCH ALTERNATE DESIGNS MAKE PROVISION FOR EQUIVALENT CAPACITY AND STRENGTH. SEE MATRIX ALL DRAINAGE STRUCTURES ARE DESIGNATED ON THE PLANS AS "MANHOLES 3X3-L", "CATCH BASINS 4-B", TOP WITH PLAIN END JOINT "INLETS 2X3-H", ETC. THE FIRST NUMBERS DESIGNATE THE SIZE OF THE STRUCTURE, AND THE FOLLOWING LETTER DESIGNATES THE TYPE OF COVER TO BE USED TO COMPRISE THE COMPLETE UNIT. BASES SHALL BE PLACED ON A BED OF MATERIAL AT LEAST 6 INCHES IN DEPTH, WHICH MEETS THE REQUIREMENTS OF FOUNDATION BACKFILL. THIS BEDDING SHALL BE COMPACTED AND PROVIDE UNIFORM " 8 SUPPORT FOR THE ENTIRE AREA OF THE BASE. 4" OVERHANGING BASE PRECAST REINFORCED FLAT SLAB TOPS MAY BE USED ON CONCRETE BLOCK STRUCTURES. 1 OR 2 2 STEPS MEETING AASHTO M199 AND THE FOLLOWING REQUIREMENTS SHALL BE INSTALLED IN ALL STRUCTURES OVER 5 FEET IN DEPTH: 16 INCH C-C MAXIMUM SPACING; PROJECT A MINIMUM CLEAR DISTANCE OF 4 INCHES FROM PLAN VIEW THE WALL AT THE POINT OF EMBEDMENT; MINIMUM LENGTH OF 10 INCHES; MINIMUM WALL EMBEDMENT OF 3 CIRCULAR OPENING SECTION A-A INCHES.
    [Show full text]
  • D400tc – Composite Manhole Cover Class D400 – En 124:1994
    Rev. 00 D400TC – COMPOSITE MANHOLE COVER CLASS D400 – EN 124:1994 DESCRIPTION PROPERTIES Manhole covers and gully tops Marked with resistance class, for use in vehicular and reference norm, producer pedestrian areas. Design identification and quality requirements, type testing, mark released by an marking, quality control internationally according to the UNI EN acknowledged certification 124:1994 standard. authority. Certificate issued by ICMQ. Made up of: - round frame - round cover - locking system with 180° or 120° hinge Name of the client or of the optional service. Embossed pattern available on request. PRODUCTION PROCESS Illustrations and drawings APPLICATION AREAS AND MATERIAL are purely illustrative Test load kN 400. The manhole cover is Carriageways (including manufactured through the pedestrian streets), SMC process, i.e. compression hardshoulders and parking moulding in a closed mould, areas for all types of road using a Sheet Moulding vehicles. Compound (polyester reinforced with glass fibres). Raw materials: orthophtalic polyester resin, chopped strand in glass fibres (type E), additives. Hinges and closing systems are made of galvanized steel. Weight of the D F H h cover + weight MODEL C/O Fixing Seal (mm) (mm) (mm) (mm) of the frame (Kg) 180° hinge and D400TC/600_001 600 690 805 100 50 Yes 36 + 17 lock 120° hinge and D400TC/600_002 600 650 790 100 48 Yes 31,6 + 13,4 lock 180° hinge and D400TC/700_001 700 750 910 100 50 Yes 45,5 + 20,5 lock Rev. 00 D400T - COMPOSITE MANHOLE COVER CLASS D400 – EN 124:1994 DESCRIPTION PROPERTIES Manhole covers and gully tops Marked with resistance class, for use in vehicular and reference norm, producer pedestrian areas.
    [Show full text]
  • Version 09-10-2019
    Version 09-10-2019 Version 09-10-19 Table of Contents SECTION 1- GENERAL REQUIREMENT ............................................................................................ 1 1.01 Short Title .................................................................................................................................... 2 1.02 Interpretation ............................................................................................................................... 2 1.03 Enforcement ................................................................................................................................ 2 1.04 Amendment ................................................................................................................................. 2 1.05 Deviation Requests ...................................................................................................................... 2 1.06 Applicability ................................................................................................................................ 3 1.07 Other Local, State and Federal Environmental Regulations .......................................................... 3 1.08 Texas Accessibility Standards (TAS) ........................................................................................... 3 1.09 Engineering Criteria – Section Descriptions ................................................................................. 4 1.10 Submittal Requirements for Construction Plans ...........................................................................
    [Show full text]
  • Safety of the Intended Functionality of Lane-Centering and Lane-Changing Maneuvers of a Generic Level 3 Highway Chauffeur System (Report No
    DOT HS 812 879 November 2020 Safety of the Intended Functionality of Lane- Centering and Lane- Changing Maneuvers of a Generic Level 3 Highway Chauffeur System DISCLAIMER This publication is distributed by the U.S. Department of Transportation, National Highway Traffic Safety Administration, in the interest of information exchange. The opinions, findings, and conclusions expressed in this publication are those of the authors and not necessarily those of the Department of Transportation or the National Highway Traffic Safety Administration. The United States Government assumes no liability for its contents or use thereof. If trade or manufacturers’ names or products are mentioned, it is because they are considered essential to the object of the publications and should not be construed as an endorsement. The United States Government does not endorse products or manufacturers. Suggested APA Format Citation: Becker, C. J., Brewer, J. C., & Yount, L. J. (2020, November). Safety of the intended functionality of lane-centering and lane-changing maneuvers of a generic level 3 highway chauffeur system (Report No. DOT HS 812 879). National Highway Traffic Safety Administration. Technical Report Documentation Page 1. Report No. 2. Government Accession No. 3. Recipient’s Catalog No. DOT HS 812 879 4. Title and Subtitle 5. Report Date Safety of the Intended Functionality of Lane-Centering and Lane-Changing November 2020 Maneuvers of a Generic Level 3 Highway Chauffeur System 6. Performing Organization Code 7. Authors 8. Performing Organization Report No. Christopher Becker, John Brewer, and Larry Yount DOT-VNTSC-NHTSA-19-02 9. Performing Organization Name and Address 10. Work Unit No.
    [Show full text]
  • Standard Construction Specifications for Storm Drain Systems Division 55 Index
    STANDARD CONSTRUCTION SPECIFICATIONS FOR STORM DRAIN SYSTEMS DIVISION 55 INDEX SECTION 55.01 GENERAL....................................................................................... 1 Article 1.1 Scope of Work................................................................................. 1 Article 1.2 Applicable Standards ...................................................................... 1 Article 1.3 Surveys ........................................................................................... 2 Article 1.4 Concrete and Mortar ....................................................................... 2 Article 1.5 Payment - General.......................................................................... 3 SECTION 55.02 FURNISH AND INSTALL PIPE....................................................... 4 Article 2.1 General ........................................................................................... 4 Article 2.2 Material ........................................................................................... 4 Article 2.3 Construction.................................................................................... 8 Article 2.4 Measurement ................................................................................ 13 Article 2.5 Basis of Payment .......................................................................... 13 SECTION 55.03 SUBDRAINS ................................................................................. 14 Article 3.1 General ........................................................................................
    [Show full text]
  • MANHOLE CASTING REFERENCE GUIDE TABLE of CONTENTS Materials………...……
    MANHOLE CASTING REFERENCE GUIDE TABLE OF CONTENTS Materials………...…….. ................................................ 2 Load Bearing.... ............................................................. 3 Key Dimensions of Round Frame and Cover ................ 3 Key Dimensions of Inlet Frame and Grate .................... 4 Frame Designs .............................................................. 5 Grate Designs ............................................................... 6 Curb Inlets or Combination Inlets ................................. 7 Watertight Frames and Covers ..................................... 8 Materials Airport Castings ............................................................. 8 QUICK REFERENCE Manhole Features .....................................................9-10 All the iron provided in a product should have a minimum recycled material content of 85%. All manufacturers should provide material certifications on product that includes country of origin and material quality and if requested, shall NATIONAL PRECAST CONCRETE ASSOCIATION provide load test data on the casting. With nearly 1,000 member companies, NPCA serves as the voice of the precast concrete industry in the United Gray Iron States and Canada. The industry includes a diverse mix Iron conforming to ASTM A48, Class 35B, as noted in of companies, from small single-plant manufacturers section 7.1.1 and 7.1.3 of AASHTO M306. Class 35B exhibits to multinational vertically integrated companies the best corrosion and wear resistance properties as well that
    [Show full text]
  • Standard Plans
    STANDARD PLANS CITY OF HUNTINGTON BEACH DEPARTMENT OF PUBLIC WORKS Series 100 and 200 –General Notes and Street Improvement Standards # Page Description Revision Date 100 1 of 4 General Notes 5/1/2008 100 2 of 4 General Notes 5/1/2008 100 3 of 4 General Notes 5/1/2008 100 4 of 4 General Notes 5/1/2008 101 Major Arterial Highway Typical Section 5/1/2008 102 Primary Arterial Highway Typical Section 5/1/2008 103 Secondary Arterial Highway Typical Section 5/1/2008 104 Local Streets Typical Section 5/1/2008 105 Knuckle Details 3/21/1994 106 Cul-de-sac 3/21/1994 107 1 of 3 Alley Approach 5/1/2008 107 2 of 3 Alley Section 5/1/2008 107 3 of 3 Alley Section 5/1/2008 108 Landscape Med. Moisture Barrier Detail 5/1/2008 109 Trench / Pavement Repair Detail 5/1/2008 110 Steel Plate Bridging 5/1/2008 111 Material Storage in R/W 5/1/2008 201 Curb Section 5/1/2008 202 Curb & Gutter Section 5/1/2008 203 1 of 2 Corner Bus Turnout 5/1/2008 203 2 of 2 Mid-Block Bus Turnout 5/1/2008 204 Residential Lot Drain 5/1/2008 205 Concrete Cross Gutter 5/1/2008 206 16' Concrete Cross Gutter 5/1/2008 207 Sidewalk and Parkway 5/1/2008 209 Residential Driveway Approach 5/1/2008 211 1 of 2 Commercial and Industrial Drive Approach 5/1/2008 211 2 of 2 Commercial and Industrial Drive Approach 5/1/2008 215 1 of 3 Utility conduit locations in r/w 5/1/2008 215 2 of 3 Utility conduit locations in r/w 5/1/2008 215 3 of 3 Utility conduit locations in r/w 5/1/2008 216 Private Street Rolled Curb 5/1/2008 217 Parkway Repair for Utility Box Installation 5/1/2008 218 3' Longitudinal
    [Show full text]
  • Plan Preparation Guide Chapter 9 Section Description Page 1 Plans
    Plan Preparation Guide Chapter 9 Drainage Structures – R.C. Box Culverts – Ditches - Gutters - Curbs Section Description Page 1 Plans for Hydrology 9-1 2 Catch Basin Types and Uses 9-2 3 Drop Inlet Types and Uses 9-5 4 Pipe End Structures and Uses 9-6 5 Catch Basin Spacing for Types 16,17, 9-7 and 18 6 Catch Basin Spacing for Type 15 9-25 7 Precast Drainage Structures 9-28 8 Pipe Requirements 9-30 9 Concrete Pipe Data 9-32 10 Beveled End Pipe 9-33 11 Pipe Tee Joints, WYE Joints, and 9-35 Bends 12 Criteria for Placing Paved Gutter 9-37 13 Culvert Sketches 9-37 14 Curb Profile 9-37 15 Green Areas 9-37 16 Trench Drain Applications 9-38 1. Plans For Hydrology Submit to Hydrology all plans (including ‘C’) that have ditches with slopes greater than 3%. Printouts of existing drainage elevations, outfall ditches and any other pertinent information will be supplied by SCDOT Road Design Section as needed. The “view only” access will be provided by the Hydraulic Engineering Office in order to share files over the network. Design Groups will copy necessary files to the ftp server for on-call consultants. Consultants should add new pipe, drainage structures, outfall ditches, and notes to plan sheets in red and new NPDES items and text in green. Department personnel will place those new additions onto the original plans upon return to Road Design. Drainage design and NPDES can be shown on the same plan sheet. If sheets become cluttered, this can be reviewed on a per case basis.
    [Show full text]
  • Technical Specification
    TECHNICAL SPECIFICATION ITEM 00470 BRICK MANHOLES 470.1 Description. This item shall govern for the construction of brick manholes on sanitary sewer lines or storm sewers, 72-inch in diameter or smaller including the materials used therein and the furnishing of frame, rings and covers. Manholes for pipe sized greater than 72-inch, use precast concrete manholes. 470.2 Materials. Reinforcing steel shall conform to the Item, "Reinforcing Steel". Concrete shall conform to the Item, "Structural Concrete". Mortar shall conform to ASTM C270, Type M, using Portland Cement. Aggregate for Mortar shall conform to ASTM C144. Cast iron shall conform to ASTM A48, Class No. 30 - Cast iron manhole frames and covers shall be manufactured to the dimensions shown on the attached drawing. Casting shall be free from sand or blow holes and other defects. Holes in cover to be free from plugs and burrs. The machined bearing surfaces of manhole frames and covers shall obtain even bearing. Cast wording "Sanitary Sewer" or "Storm Sewer", as applicable. Thirty-two (32) inch manhole covers will be used on all manholes. Concrete brick shall be in accordance with ASTM C55, Grade A. Concrete brick is not allowed for the construction of sanitary sewer manholes. Bricks shall be of first quality, sound, hard-burned perfectly shaped brick. Shale bricks, if used, shall be homogeneous thoroughly and uniformly burned. Bricks shall not absorb more than 16- percent of water by weight when submerged in water for 24-hours, having been in a completely dry state prior to placing in water. Clay brick shall conform to the requirements of ASTM Designation C32, Grade NA, except that not more than 16% maximum individual brick absorption will be permitted.
    [Show full text]
  • Manhole Cover Finishes Detail - in Road Proj Origin Zone Level Type Role Number 232207-70 232207-70-AR-01-XX-DR-C-00200
    Mortar bedding and haunching 600 mm x 600 mm clear opening 600 mm x 600 mm clear opening to cover and frame Plastic chambers and rings shall comply with BS EN 13598-1 and NOTES:- cover complying with cover complying with to Clause E6.7 BS EN 124 and BS 7903 Mortar bedding and haunching BS EN 13598-2 or have equivalent independent approval BS EN 124 and BS 7903 1. Refer to drawing CD 002 for general notes. See Clause E2.32 to cover and frame Minimum 2 courses of Class B See Clause E2.32 Cover complying with to Clause E6.7 Sited in driveways/paved areas engineering bricks BS EN 124 and BS 7903 Minimum 2 courses of Class B 2. All dimensions in millimeters unless otherwise or precast concrete Mortar bedding and haunching to Driveways, footways and engineering bricks or precast noted. cover frame seating rings cover and frame to Clause E6.7 landscaped areas - Class B125 Minimum clear access 600 mm concrete cover frame seating rings 150 mm deep concrete collar See Clause E2.32 Minimum clear access 600 mm 3. This drawing to be read in conjunction with other Minimum radius to be 500 mm Minimum internal dimensions Precast concrete manhole for a 100 mm diameter pipe and 180 mm diameter or engineers and architects drawings. sections and cover slab to be 600 mm for a 150 mm diameter 225 mm x 100 mm bedded with mortar, plastomeric In-situ concrete to be GEN3 pipe to allow entry of DOT Type 1 sub base 4.
    [Show full text]
  • Precast Reinforced Concrete Manholes
    VALLECITOS WATER DISTRICT SECTION 03461 – PRECAST REINFORCED CONCRETE MANHOLES PART 1 – GENERAL 1.1 DESCRIPTION A. This section includes materials, testing, and installation of precast concrete manholes, manhole bases, manhole frames, and covers. 1.2 RELATED WORK SPECIFIED ELSEWHERE A. All related work specified elsewhere, or in other codes or standards, will be as last revised, unless a specific date of issuance is called out in opposition to later revision date(s). B. Other sections of the Standard Specifications, not referenced below, shall also apply to the extent required for proper performance of this Work. 1. Section 02223 - Trenching, Backfilling, and Compacting 2. Section 03300 – Concrete 3. Section 09801 - Manhole Protective Lining 4. Section 15042 - Leakage and Infiltration Testing 1.3 REFERENCE SPECIFICATIONS, CODES, AND STANDARDS A. The following standards have been referenced in this Section: 1. ASTM A48 Gray Iron Castings 2. ASTM A536 Ductile Iron Casting 3. ASTM C478 Precast Reinforced Concrete Manhole Sections 1.3 SUBMITTALS A. Submit manufacturer’s catalog and test data on precast concrete manholes, frames, and covers along with installation recommendations for inlet and outlet seals and watertight caulking. Show dimensions and materials of construction by ASTM reference and grade. Show manhole cover lettering and pattern. 1.4 PROJECT CONDITIONS A. Any proposed work inside an existing manhole that is part of a sewage system in service, shall not be undertaken until all the tests and safety provisions of Article 4, Section 1532 “Confined Spaces” State of California Construction Safety Orders have been made. PART 2 – PRODUCTS 2.1 PRECAST CONCRETE MANHOLES VWD NOVEMBER 2017 SECTION 03461 - 1 of 6 VALLECITOS WATER DISTRICT SECTION 03461 – PRECAST REINFORCED CONCRETE MANHOLES A.
    [Show full text]